Usability of the FTEXES Wearable Textile Platform for Functional Electrical Stimulation and EMG
Condition(s) studied
Investigational drug(s) / intervention(s)
FTEXES wearable system: Sensorized textile garments (Smart Pants for the lower limb, Smart T-shirt for the upper limb) with integrated textile electrodes, connected to a CE-marked FES stimulator (HASOMED RehaMove3) and a CE-marked surface EMG system (FreeEMG 1000). Single session of about 45-60 minutes: donning, setup, calibration, functional tasks (gait cycle or reaching/grasping), doffing and skin inspection.
Study summary
FTEXES (Functionalized TEXtiles for Electrical Stimulation) is a wearable platform based on sensorized garments (Smart Pants and Smart T-shirt) with integrated textile electrodes for surface electromyography (EMG) recording and functional electrical stimulation (FES). This single-center, open-label, non-randomized study evaluates the usability of the system in a controlled laboratory setting. Fifteen participants (5 healthy adults, 5 patients with neuromotor disability, 5 healthcare professionals) take part in a single 45-60 minute session including donning, system setup, calibration, functional tasks (gait for the lower limb; reaching and grasping for the upper limb), doffing and skin inspection. Comfort, skin tolerability, stimulation-related discomfort, perceived usability, satisfaction and acceptability are assessed with standardized questionnaires. The quality of EMG signals recorded with textile electrodes is evaluated as a secondary objective. The study has no therapeutic purpose for individual participants.
Eligibility
Primary outcome measure(s)
- Perceived usability: System Usability Scale (SUS) score — During and at the end of the single experimental session (approximately 60 minutes)
SUS is a 10-item questionnaire scored from 0 to 100; higher scores indicate better perceived usability. - Wearable comfort: Comfort Rating Scale (CRS) score — During and at the end of the single experimental session (approximately 60 minutes)
Comfort of the textile garments and textile electrodes assessed with the Comfort Rating Scale (CRS); higher scores indicate greater discomfort. - Stimulation-related pain/discomfort (NRS/VAS 0-10) — During and at the end of the single experimental session (approximately 60 minutes)
Global and localized discomfort, perceived fatigue and pain associated with functional electrical stimulation, rated on a 0-10 numeric/visual analogue scale; 0 = none, 10 = worst imaginable. - Satisfaction with the assistive device: adapted QUEST 2.0 — During and at the end of the single experimental session (approximately 60 minutes)
Satisfaction with the FTEXES system assessed with an adapted version of the Quebec User Evaluation of Satisfaction with Assistive Technology (QUEST 2.0); items scored 1-5, higher scores indicate greater satisfaction. - Acceptability and intention to use: Net Promoter Score (NPS) and intention-to-use questionnaire — During and at the end of the single experimental session (approximately 60 minutes)
Likelihood to recommend the system (NPS, 0-10 rating, summarized as -100 to +100) and intention to use the platform in the future, including at home.
Trial sites (1)
| Facility | City | Region | Status |
|---|---|---|---|
| IRCCS Eugenio Medea - Associazione La Nostra Famiglia | Bosisio Parini | Lecco |
Other trials for the same condition
This page summarises publicly available registry data for informational purposes — not medical advice. Eligibility is determined by each study team; patients should discuss participation with their clinician.
View NCT07922980 on ClinicalTrials.gov ↗ ← All trials in Italy