Ireland
--:--IST
Starting soon Observational

Assessment of Flow in Cerebrospinal Fluid Shunts With a Second Generation Wireless Thermal Anisotropy Measurement Device

NCT06409286 · tracked via the Priya Life Science USA tracker
Phase
Observational
Started
2025-07
Last updated
2025-05-15

Condition(s) studied

Hydrocephalus

Investigational drug(s) / intervention(s)

Thermal Anisotropy Measurement Device

Thermal Anisotropy Measurement Device: A wireless device for non-invasively assessing CSF shunt flow

Study summary

This study evaluates the performance of a thermal anisotropy measurement device for non-invasively assessing CSF shunt flow. Patients with an existing implanted shunt and symptoms of shunt malfunction who require shunt revision surgery will be evaluated with the study device to assess flow in CSF shunts as confirmed by surgical outcomes at 7 days. If successful, this study will show that the study device accurately distinguishes between functioning (flowing) and non-functioning (non-flowing) shunts.

Eligibility

Sex
ALL
Min age
—
Max age
—
Healthy volunteers
No
Inclusion Criteria: 1. Existing ventriculoperitoneal CSF shunt on which the subject is dependent 2. At least one symptom of shunt malfunction as determined by the investigator, such as but not limited to seizure, fever, headache, vision problems, dizziness, disorientation, confusion, vomiting, lethargy, irritability, difficulty waking or staying awake, swelling along shunt tract, enlargement of head, loss of balance, gait disturbance, and loss of sensory or motor function 3. Exhibit shunt malfunction symptom(s) requiring surgical shunt revision per standard of care assessment without use of device data 4. Region of intact skin overlying an unambiguously identifiable chronically indwelling ventricular shunt which crosses the clavicle and is appropriate in size for application of the study device 5. Available for follow-up for up to seven days 6. Signed informed consent by subject or a parent, legal guardian, health care agent, or surrogate decision maker (according to local statutes, and collectively referred to as "surrogates" in this protocol) Exclusion Criteria: 1. Presence of more than one distal shunt catheter in the study device measurement region 2. Presence of an interfering open wound or edema in the study device measurement area 3. Subject-reported history of adverse skin reactions to adhesives 4. Investigator judges that the subject is likely to be lost to follow-up due to unavailability or clinical outcome being unobtainable 5. Participation in the study will interfere with, or be detrimental to, administration of optimal health-care to the subject 6. Previous participation in a Rhaeos clinical study in which FlowSense device measurement data were acquired 7. Participation in any other investigational procedural, pharmaceutical, and/or device study that may influence the collection of valid data under this study

Primary outcome measure(s)

  • Flowsense Sensitivity — Upto 7 days
    The study device will yield an output of either "flow confirmed" or "flow not confirmed." Based on this assessment and the standard-of-care clinical treatment, each subject will fall into one of the following categories: True Positive (TP): Device outputs "flow not confirmed" AND a shunt revision surgery with confirmed shunt failure is performed False Positive (FP): Device outputs "flow not confirmed" AND either no shunt revision surgery is performed for 7 days or a shunt revision surgery without a confirmed shunt failure is performed True Negative (TN): Device outputs "flow confirmed" AND either no shunt revision surgery is performed for 7 days or a shunt revision surgery without a confirmed shunt failure is performed False Negative (FN): Device outputs "flow confirmed" AND a shunt revision surgery with confirmed shunt failure is performed Study device sensitivity will be calculated as TP / (TP + FN).

Trial sites (1)

FacilityCityRegionStatus
Washington University in St. Louis St Louis Missouri
Official registry record

This page summarises publicly available registry data for informational purposes — not medical advice. Eligibility is determined by each study team; patients should discuss participation with their clinician.