Carotid Ultrasound Under Pulsed-wave Doppler Mode to Check the Pulse in Cardiopulmonary Arrest Patients.

NCT04790396 · tracked via the Priya Life Science Taiwan tracker
Phase
Observational
Started
2020-12-01
Last updated
2026-09-18

Condition(s) studied

Cardiac Arrest

Investigational drug(s) / intervention(s)

Carotid ultrasound under pulsed-wave doppler mode

Carotid ultrasound under pulsed-wave doppler mode: Carotid ultrasound under pulsed-wave doppler mode to check whether carotid pulse is present

Study summary

It's crucial to determine whether a pulse is present or not in patient with cardiac arrest. But more and more studies have shown that manual palpation is unreliable for detecting pulse 1-4. Failure to detect pulselessness may cause delay of chest compression and directly affect the patient's outcome. Likewise, failure to rapidly detect return of spontaneous circulation may cause prolonged chest compression and increase associated injury during resuscitation.

More and more studies have demonstrated that echo guided pulse detection is feasible 5-7. The aim of our study is to check carotid pulse via ultrasound. This is a prospective study and the patient selection is in-hospital or out of hospital cardiac arrest. A curvilinear ultrasonography transducer is used and placed transversely on either right/left carotid artery under pulsed-wave doppler mode to check whether the pulse is present or not. The result of ultrasonography will be compared with manual palpation and to determine the accuracy and effectiveness of clinical usage.

Eligibility

Sex
ALL
Min age
20 Years
Max age
—
Healthy volunteers
No
Inclusion Criteria: * any patient presenting at ER with cardiac arrest older than 20 years-old Exclusion Criteria: * younger than 20 years-old * patient who is pregnant

Primary outcome measure(s)

  • Carotid ultrasound under pulsed-wave doppler compared with manual palpation — 5 seconds during pulse check period of resuscitation
    The result of ultrasonography will be compared with manual palpation and to determine the accuracy(e.g., no pulse under manual palpation but positive pulse-wave finding)of clinical usage.
  • Carotid ultrasound under pulsed-wave doppler compared with manual palpation — 5 seconds during pulse check period of resuscitation
    The result of ultrasonography will be compared with manual palpation and to determine the effectiveness (e.g., the time need to confirm whether pulse is present or not under manual palpation and ultrasound) of clinical usage.