Clinical Performance Study of Microbio InfectID-BSI for Detection of Bacteria and Yeast With Patient Blood Samples
Condition(s) studied
Investigational drug(s) / intervention(s)
InfectID-BSI (Bloodstream Infection) qPCR Assay: InfectID-BSI technology targets nucleic acid sequences unique to the target analyte. The qPCR raw data collected from InfectID-BSI's 9 assay tubes is analysed by Microbio's InfectID-Client (InfectID-BSI-associated software) and the result is reported as an analyte-detection if the unique target analyte is present or no result if the unique target analyte is absent. InfectID-BSI is carried out with whole blood from a venous puncture (EDTA). DNA is extracted from a sample of the collected blood using a validated DNA extraction instrument according to the manufacturer's instructions. The extracted DNA is then added to the InfectID-BSI qPCR reagent panel which consists of 9 reaction tubes (6 for bacteria, and 3 for yeast species). The panel is subjected to real-time qPCR using a process of Melt Curve analysis using the Rotor-Gene Q MDx qPCR instrument. The assay report identifies the species present in the sample upon completion. Results are generated within 3 hours.
Study summary
The objective of the study is to determine the efficacy of the Microbio InfectID-BSI qPCR kit in a clinical laboratory environment using patient whole blood for pathogen detection and identification versus standard of care methods from blood culture.
The objective of this study is to determine the sensitivity and specificity of the Microbio InfectID-BSI qPCR kit by the evaluation of clinical blood samples versus standard of care methods from blood culture.
Eligibility
Primary outcome measure(s)
- Determine the sensitivity and specificity of InfectID-BSI versus blood culture. — Through study completion, an average of 1 year
The objective of this study is to determine the sensitivity and specificity of the Microbio InfectID-BSI qPCR kit by the evaluation of clinical blood samples versus standard of care methods from blood culture. - Determine the efficacy of detection and identification of the 26-pathogen panel in the InfectID-BSI assay versus standard of care blood culture. Using qPCR - a new molecular technology to identify the top 20 bacterial and 6 yeast sepsis causing species. — Through study completion, an average of 1 year
The objective of the study is to determine the efficacy of the Microbio InfectID-BSI qPCR kit in a clinical laboratory environment using patient whole blood for pathogen detection and identification versus standard of care methods from blood culture. InfectID has it's own reporting software - InfectID-Client which is how the InfectID-BSI results will be reported for the study.
Trial sites (8)
| Facility | City | Region | Status |
|---|---|---|---|
| Indiana University Hospital | Indianapolis | Indiana | |
| University of Maryland | Baltimore | Maryland | |
| TriCore Reference Laboratories | Albuquerque | New Mexico | |
| Vanderbilt University Medical Centre | Nashville | Tennessee | |
| Texas Children's Hospital | Houston | Texas | |
| The Prince Charles Hospital | Chermside | Queensland | |
| The Princess Alexandra Hospital | Woolloongabba | Queensland | |
| Southwest Regional Laboratory, UK Health Security Agency, Bristol UK | Bristol | United Kingdom |