MicroVention, Inc. Flow Re-Direction Endoluminal Device X (FRED™ X™) Post-Approval Study
Condition(s) studied
Investigational drug(s) / intervention(s)
FRED™ X™: The FRED™ X™ System is indicated for use in the internal carotid artery from the petrous segment to the terminus for the endovascular treatment.
Study summary
The objective of this study is to generate contemporaneous clinical data to facilitate a reasonable comparison of the performance of the FRED™ X™ device with the performance of the FRED™ device. The data generated from this study will be compared to the safety and effectiveness of the FRED™ device by meeting the same performance goals (PGs) established for the FRED™ pivotal study.
Eligibility
Primary outcome measure(s)
- Primary Safety Endpoint Part 1: Proportion of subjects that experience either Death or major stroke within 30 days post-procedure. — 30-days
Major stroke is defined as a new neurological event that persists for \>24 hours and results in a ≥4-point increase in the NIHSS score compared to baseline or compared to any subsequent lower score. - Primary Safety Endpoint Part 2: Proportion of subjects that experience neurological death or major ipsilateral stroke within 12 months post-procedure. — 12 months
A major ipsilateral stroke is defined as that occurring within the vascular distribution of the stented artery. Neurological death is defined as a death which has been adjudicated by an independent clinical events committee to have directly resulted from a neurologic cause. - Primary Effectiveness Endpoint: The percent of subjects with (1) complete (100%) occlusion of the target aneurysm and ≤50% stenosis of the parent artery at the target IA, and (2) in whom an alternative treatment of the target IA had not been performed. — 12 months
(1) Complete (100%) occlusion of the target aneurysm is assessed utilizing the Raymond-Roy Scale (Raymond Roy Class 1) and ≤50% stenosis of the parent artery at the target IA), and in whom an alternative treatment of the target IA had not been performed. The study will utilize independent Core Laboratory to adjudicate all angiographic outcomes, including aneurysm occlusion status and parent artery stenosis. (2) Alternative treatment is defined as re-treatment of the target aneurysm with an alternative treatment modality including open repair, endovascular placement of an additional stent or treatment of in-stent stenosis.
Trial sites (23)
| Facility | City | Region | Status |
|---|---|---|---|
| Memorial Healthcare Systems | Hollywood | Florida | |
| Orlando Health | Orlando | Florida | |
| Queen's Medical Center | Honolulu | Hawaii | |
| University of Iowa | Iowa City | Iowa | |
| University of Kansas | Kansas City | Kansas | |
| Baptist Healthcare System | Louisville | Kentucky | |
| Norton Healthcare | Louisville | Kentucky | |
| Ochsner Health | New Orleans | Louisiana | |
| The Johns Hopkins University | Baltimore | Maryland | |
| Massachusetts General Brigham Incorporated | Boston | Massachusetts | |
| UMass Memorial Health | Worcester | Massachusetts | |
| Albany Medical Center | Albany | New York | |
| University at Buffalo | Buffalo | New York | |
| Northwell Health | Manhasset | New York | |
| Mount Sinai | New York | New York | |
| Stony Brook University | Stony Brook | New York | |
| Montefiore Medical Center | The Bronx | New York | |
| Ohio State University | Columbus | Ohio | |
| ProMedica Toledo Hospital | Toledo | Ohio | |
| University of Oklahoma Health Sciences Center | Oklahoma City | Oklahoma | |
| University of Pennsylvania | Philadelphia | Pennsylvania | |
| Thomas Jefferson University | Philadelphia | Pennsylvania | |
| Houston Methodist Hospital | Houston | Texas |
More Microvention-Terumo, Inc. trials in the USA
Other trials for the same condition
This page summarises publicly available registry data for informational purposes — not medical advice. Eligibility is determined by each study team; patients should discuss participation with their clinician.
View NCT05409989 on ClinicalTrials.gov ↗ ← All trials in the USA