Closed-loop in Adults With Type 2 Diabetes
Condition(s) studied
Investigational drug(s) / intervention(s)
CamAPS HX: The automated closed loop system (CamAPS HX) will consist of: YpsoPump insulin pump Freestyle Libre 3 glucose sensor Smartphone hosting CamAPS HX app with the Cambridge model predictive control algorithm
Standard insulin therapy with glucose sensor: Participants usual insulin therapy with Freestyle Libre 3 glucose sensor
Study summary
The main objective of this study is to determine the efficacy, safety and utility of fully closed-loop glucose control in the home setting in adults with type 2 diabetes (T2D). This study builds on previous and on-going studies of closed-loop systems that have been performed in Cambridge in adults with type 2 diabetes in the inpatient and in the home setting and in children and adults with type 1 diabetes.
This is an open-label, multi-national, multi-centre, randomised, single-period parallel study, involving a run-in period followed by a 26-week intervention period during which glucose levels will be controlled either by a fully closed-loop system or by participants usual insulin therapy with continuous glucose monitoring. A total of up to 224 adults with type 2 diabetes using insulin will be recruited through outpatient diabetes clinics, primary care centres, social media advertising and other established methods at participating centres. Participants will receive appropriate training in the safe use of the study devices.
The primary outcome is the between group difference in HbA1c at 26 weeks. Other key outcomes include the time spent with glucose levels within, above and below the target glucose range (3.9-10.0mmol/L) and mean sensor glucose as recorded by CGM over the 26 weeks. Insulin requirements, body weight, renal and liver function will also be compared. Safety evaluation comprises severe hypoglycaemic episodes, and other adverse and serious adverse events. Human factors outcomes include CGM \& closed-loop usage, questionnaires and semi-structured interviews.
Eligibility
Primary outcome measure(s)
- Glycated haemoglobin (HbA1c) at 26 weeks — at 26 weeks
Centralised measurement of HbA1c
Trial sites (12)
| Facility | City | Region | Status |
|---|---|---|---|
| University of Melbourne | Melbourne | Australia | Not Yet Recruiting |
| Medical University of Graz | Graz | Austria | Not Yet Recruiting |
| Diabetes Centre, Institute of Clinical and Experimental Medicine | Prague | Czechia | Not Yet Recruiting |
| CHU de Toulouse | Toulouse | France | Not Yet Recruiting |
| Bern University Hospital | Bern | Switzerland | Not Yet Recruiting |
| Addenbrooke's Hospital, Cambridge University Hospitals NHS Foundation Trust | Cambridge | United Kingdom | Recruiting |
| Royal Derby Hospital | Derby | United Kingdom | Not Yet Recruiting |
| Leicester Diabetes Centre | Leicester | United Kingdom | Recruiting |
| Guy's and St Thomas' NHS Foundation Trust | London | United Kingdom | Recruiting |
| King's College Hospital, King's College NHS Foundation Trust | London | United Kingdom | Recruiting |
| Manchester Royal Infirmary, Central Manchester University Hospitals NHS Foundation Trust | Manchester | United Kingdom | Not Yet Recruiting |
| Norfolk and Norwich University Hospital | Norwich | United Kingdom | Recruiting |
This page summarises publicly available registry data for informational purposes — not medical advice. Eligibility is determined by each study team; patients should discuss participation with their clinician.
View NCT06579404 on ClinicalTrials.gov ↗ ← All trials in Switzerland