Ireland
--:--IST
Latest
Astellas Expands Its 330 Million Euro Tralee Biopharma Facility with a Second Aseptic Filling Line to Double Drug-Product Capacity Xeolas Pharmaceuticals Opens 158,000 Sq Ft State-of-the-Art Baldoyle Facility to Scale Specialty Medicine Manufacturing Priya Life Science Partners with Fleming for the 9th Annual Corporate Compliance & Transparency in Life Sciences Summit in Zurich Ireland Has the Capital and the Lessons: Digital Project Management Is How They Become Delivery Dunbar Pharma Brings First Plant-Derived Dronabinol API to UK Market Through IPS Pharma Leveraging Priya Life Science as a Data Tracker: The Ultimate Use Case & Career Guide The €100K Reality Check: Why a Six-Figure Pharma Salary in Ireland Feels Different Than in Switzerland or Germany Ireland's €93.8 Billion Non-EU Pharma Export Engine: Trade Data, Destination Markets, and Economic Impact Astellas Expands Its 330 Million Euro Tralee Biopharma Facility with a Second Aseptic Filling Line to Double Drug-Product Capacity Xeolas Pharmaceuticals Opens 158,000 Sq Ft State-of-the-Art Baldoyle Facility to Scale Specialty Medicine Manufacturing Priya Life Science Partners with Fleming for the 9th Annual Corporate Compliance & Transparency in Life Sciences Summit in Zurich Ireland Has the Capital and the Lessons: Digital Project Management Is How They Become Delivery Dunbar Pharma Brings First Plant-Derived Dronabinol API to UK Market Through IPS Pharma Leveraging Priya Life Science as a Data Tracker: The Ultimate Use Case & Career Guide The €100K Reality Check: Why a Six-Figure Pharma Salary in Ireland Feels Different Than in Switzerland or Germany Ireland's €93.8 Billion Non-EU Pharma Export Engine: Trade Data, Destination Markets, and Economic Impact
Active, not recruiting Not applicable

Medtronic Evolut Transcatheter Aortic Valve Replacement in Low Risk Patients

NCT02701283 · tracked via the Priya Life Science Japan tracker
Phase
Not applicable
Started
2016-03
Last updated
2026-05-07

Condition(s) studied

Aortic Valve Stenosis

Investigational drug(s) / intervention(s)

Medtronic Transcatheter Aortic Valve Replacement SystemsSurgical Aortic Valve Replacement (SAVR)

Medtronic Transcatheter Aortic Valve Replacement Systems: Treatment of severe aortic stenosis in subjects who have a low predicted risk of operative mortality for SAVR with Medtronic TAVR Systems

Surgical Aortic Valve Replacement (SAVR): Treatment of severe aortic stenosis in subjects who have a low predicted risk of operative mortality for SAVR with a commercially approved surgical bioprothesis

Study summary

The study objective is to demonstrate that the safety and effectiveness of the Medtronic TAVR system as measured by rates of all-cause mortality or disabling stroke at two years is noninferior to SAVR in the treatment of severe aortic stenosis in subjects who have a low predicted risk of operative mortality for SAVR.

The purpose of the expanded use addendum to the Medtronic TAVR in Low Risk Patients Trial protocol is to conclude the randomized phase of the trial and initiate the single-arm, non-randomized, continued access phase of the trial.

Eligibility

Sex
ALL
Min age
—
Max age
—
Healthy volunteers
No
Inclusion Criteria: 1. Severe aortic stenosis, defined as follows: 1. For symptomatic patients: Aortic valve area ≤1.0 cm2 (or aortic valve area index of ≤0.6 cm2/m2), OR mean gradient ≥40 mmHg, OR Maximal aortic valve velocity ≥4.0 m/sec by transthoracic echocardiography at rest 2. For asymptomatic patients: * Very severe aortic stenosis with an aortic valve area of ≤1.0 cm2 (or aortic valve area index of ≤0.6 cm2/m2), AND maximal aortic velocity ≥5.0 m/sec , or mean gradient ≥60 mmHg by transthoracic echocardiography at rest, OR * Aortic valve area of ≤1.0 cm2 (or aortic valve area index of ≤0.6 cm2/m2), AND a mean gradient ≥40 mmHg or maximal aortic valve velocity ≥4.0 m/sec by transthoracic echocardiography at rest, AND an exercise tolerance test that demonstrates a limited exercise capacity, abnormal BP response, or arrhythmia OR * Aortic valve area of ≤1.0 cm2 (or aortic valve area index of ≤0.6 cm2/m2), AND mean gradient ≥40 mmHg, or maximal aortic valve velocity ≥4.0 m/sec by transthoracic echocardiography at rest, AND a left ventricular ejection fraction \<50%. 2. Documented heart team agreement of low risk for SAVR, where low risk is defined as predicted risk of mortality for SAVR \<3% at 30 days per multidisciplinary local heart team assessment. 3. The subject and the treating physician agree that the subject will return for all required post-procedure follow-up visits. Exclusion Criteria: 1. Any condition considered a contraindication for placement of a bioprosthetic valve (eg, subject is indicated for mechanical prosthetic valve). 2. A known hypersensitivity or contraindication to any of the following that cannot be adequately pre-medicated: 1. aspirin or heparin (HIT/HITTS) and bivalirudin 2. ticlopidine and clopidogrel 3. Nitinol (titanium or nickel) 4. contrast media 3. Blood dyscrasias as defined: leukopenia (WBC \<1000 mm3), thrombocytopenia (platelet count \<50,000 cells/mm3), history of bleeding diathesis or coagulopathy, or hypercoagulable states. 4. Ongoing sepsis, including active endocarditis. 5. Any percutaneous coronary or peripheral interventional procedure with a bare metal stent within 30 days prior to randomization, or drug eluting stent performed within 180 days prior to randomization. 6. Multivessel coronary artery disease with a Syntax score \>22 and/or unprotected left main coronary artery. 7. Symptomatic carotid or vertebral artery disease or successful treatment of carotid stenosis within 10 weeks of Heart Team assessment. 8. Cardiogenic shock manifested by low cardiac output, vasopressor dependence, or mechanical hemodynamic support. 9. Recent (within 2 months of Heart Team assessment) cerebrovascular accident (CVA) or transient ischemic attack (TIA). 10. Gastrointestinal (GI) bleeding that would preclude anticoagulation. 11. Subject refuses a blood transfusion. 12. Severe dementia (resulting in either inability to provide informed consent for the trial/procedure, prevents independent lifestyle outside of a chronic care facility, or will fundamentally complicate rehabilitation from the procedure or compliance with follow-up visits). 13. Estimated life expectancy of less than 24 months due to associated non-cardiac co-morbid conditions. 14. Other medical, social, or psychological conditions that in the opinion of the investigator precludes the subject from appropriate consent or adherence to the protocol required follow-up exams. 15. Currently participating in an investigational drug or another device trial (excluding registries). 16. Evidence of an acute myocardial infarction ≤30 days before the trial procedure due to unstable coronary artery disease (WHO criteria). 17. Need for emergency surgery for any reason. 18. Subject is pregnant or breast feeding. 19. Subject is less than legal age of consent, legally incompetent, or otherwise vulnerable 20. Pre-existing prosthetic heart valve in any position. 21. Severe mitral regurgitation amenable to surgical replacement or repair. 22. Severe tricuspid regurgitation amenable to surgical replacement or repair. 23. Moderate or severe mitral stenosis amenable to surgical replacement or repair. 24. Hypertrophic obstructive cardiomyopathy with left ventricular outflow gradient. 25. Bicuspid aortic valve verified by echocardiography, MDCT, or MRI. 26. Prohibitive left ventricular outflow tract calcification. 27. Sinus of Valsalva diameter unsuitable for placement of the self-expanding bioprosthesis. 28. Aortic annulus diameter of \<18 or \>30 mm. 29. Significant aortopathy requiring ascending aortic replacement. For transfemoral or transaxillary (subclavian) access: 30. Access vessel mean diameter \<5.0 mm for Evolut 23R, 26R, or 29R mm TAV, or access vessel mean diameter \<5.5 mm for Evolut 34R mm or Evolut PRO TAV. However, for transaxillary (subclavian) access in patients with a patent LIMA, access vessel mean diameter \<5.5mm for Evolut 23R, 26R, or 29R mm TAV, or access vessel mean diameter \<6.0 mm for the Evolut 34R or Evolut PRO TAV.

Primary outcome measure(s)

  • Safety: All Cause Mortality or Disabling Stroke Rate at 24 Months, Randomized Controlled Trial Safety: All Cause Mortality or All Stroke Rate at 12 Months, Continued Access Study — Randomized Controlled Trial - 24 months Continued Access Study - 12 months
    Assessment of procedural safety by: All-cause mortality: all deaths from any cause after valve intervention. This includes all cardiovascular and non-cardiovascular deaths. Disabling stroke: a modified rankin score (mRS) of 2 or more at 90 days post-stroke and an increase of at least one mRS category from an individual's pre-stroke baseline. All stroke: any stroke after valve intervention (ischemic, hemorrhagic, or undetermined stroke).

Trial sites (87)

FacilityCityRegionStatus
Abrazo Arizona Heart Hospital Phoenix Arizona
Scripps Memorial Hospital La Jolla La Jolla California
University of Southern California University Hospital Los Angeles California
El Camino Hospital Mountain View California
Mercy General Hospital Sacramento California
Los Robles Hospital & Medical Center Thousand Oaks California
University of Colorado Hospital Aurora Colorado
Yale New Haven Hospital New Haven Connecticut
Morton Plant Hospital Clearwater Florida
Delray Medical Center Delray Beach Florida
HealthPark Medical Center Fort Myers Florida
University of Miami Hospital Miami Florida
Tallahassee Research Institute, Inc. Tallahassee Florida
Piedmont Atlanta Hospital Atlanta Georgia
Loyola University Medical Center Maywood Illinois
Saint Vincent Heart Center of Indiana Indianapolis Indiana
Mercy Medical Center Des Moines Iowa
The University of Kansas Hospital Kansas City Kansas
Jewish Hospital Louisville Kentucky
Terrebonne General Medical Center Houma Louisiana
University of Maryland Medical Center Baltimore Maryland
MedStar Union Memorial Hospital Baltimore Maryland
The Johns Hopkins Hospital Baltimore Maryland
Massachusetts General Hospital Boston Massachusetts
Beth Israel Deaconess Medical Center Boston Massachusetts
Baystate Medical Center Springfield Massachusetts
University of Michigan Health System Ann Arbor Michigan
Saint John Hospital and Medical Center Detroit Michigan
Spectrum Health Hospitals Grand Rapids Michigan
Abbott Northwestern Hospital Minneapolis Minnesota
Mercy Hospital Springfield Missouri
Saint Francis Hospital East Hills New York
Saint Joseph's Hospital Health Center Liverpool New York
Northwell Health Manhasset New York
The Mount Sinai Hospital New York New York
Strong Memorial Hospital Rochester New York
Duke University Medical Center Durham North Carolina
Wake Forest Baptist Medical Center Winston-Salem North Carolina
Sanford Medical Center Fargo North Dakota
Good Samaritan Hospital Cincinnati Ohio

+ 47 more sites — see the full list on the official registry below.

More Medtronic Cardiovascular trials in Japan

Official registry record

This page summarises publicly available registry data for informational purposes — not medical advice. Eligibility is determined by each study team; patients should discuss participation with their clinician.

View NCT02701283 on ClinicalTrials.gov ↗ ← All trials in Japan