Ireland
--:--IST
Latest
Astellas Expands Its 330 Million Euro Tralee Biopharma Facility with a Second Aseptic Filling Line to Double Drug-Product Capacity Xeolas Pharmaceuticals Opens 158,000 Sq Ft State-of-the-Art Baldoyle Facility to Scale Specialty Medicine Manufacturing Priya Life Science Partners with Fleming for the 9th Annual Corporate Compliance & Transparency in Life Sciences Summit in Zurich Ireland Has the Capital and the Lessons: Digital Project Management Is How They Become Delivery Dunbar Pharma Brings First Plant-Derived Dronabinol API to UK Market Through IPS Pharma Leveraging Priya Life Science as a Data Tracker: The Ultimate Use Case & Career Guide The €100K Reality Check: Why a Six-Figure Pharma Salary in Ireland Feels Different Than in Switzerland or Germany Ireland's €93.8 Billion Non-EU Pharma Export Engine: Trade Data, Destination Markets, and Economic Impact Astellas Expands Its 330 Million Euro Tralee Biopharma Facility with a Second Aseptic Filling Line to Double Drug-Product Capacity Xeolas Pharmaceuticals Opens 158,000 Sq Ft State-of-the-Art Baldoyle Facility to Scale Specialty Medicine Manufacturing Priya Life Science Partners with Fleming for the 9th Annual Corporate Compliance & Transparency in Life Sciences Summit in Zurich Ireland Has the Capital and the Lessons: Digital Project Management Is How They Become Delivery Dunbar Pharma Brings First Plant-Derived Dronabinol API to UK Market Through IPS Pharma Leveraging Priya Life Science as a Data Tracker: The Ultimate Use Case & Career Guide The €100K Reality Check: Why a Six-Figure Pharma Salary in Ireland Feels Different Than in Switzerland or Germany Ireland's €93.8 Billion Non-EU Pharma Export Engine: Trade Data, Destination Markets, and Economic Impact
Recruiting Not applicable

Head-to-Head Comparison of Five Enhanced Depth of Focus IOLs and One Monofocal IOL

NCT07051720 · tracked via the Priya Life Science Germany tracker
Sponsor
Augenklinik Ahaus G + H GmbH & Co. KG
Phase
Not applicable
Started
2022-04-12
Last updated
2025-07-04

Condition(s) studied

Cataract and IOL SurgeryIOL ImplantationPresbyopia CorrectionExtended Depth of Focus

Investigational drug(s) / intervention(s)

Bilateral implantation of CT ASPHINA 409MBilateral implantation of TECNIS Eyhance ICB00Bilateral implantation of AcrySof® IQ Vivity®Bilateral implantation of LuxSmart™Bilateral implantation of Eyecryl SERTBilateral implantation of RayOne EMV

Bilateral implantation of CT ASPHINA 409M: Patients will be implanted with CT ASPHINA 409M during catarct surgery. The CT Asphina 409M has been commercially available for several years and is widely used in clinical practice. Designed with aberration-neutral optical properties, it could improve contrast sensitivity and visual quality. This monofocal aspheric IOL features four-point plate haptics and a one-piece design made from hydrophilic acrylic material with hydrophobic surface properties. It also has an overall diameter of 11 mm and a 6 mm optical diameter. The lens has a sharp posterior optic edge to minimize posterior capsule opacification. It is ideally suited as a comparative referent lens to new EDOF IOLs.

Bilateral implantation of TECNIS Eyhance ICB00: Patients will be implanted with TECNIS Eyhance ICB00 during catarct surgery. TECNIS Eyhance ICB00 is a one-piece, posterior chamber lens with an overall diameter of 13.0 mm and an optic diameter of 6.0 mm. The lens has a spherical posterior surface and a modified aspheric anterior surface that offers a smooth and continuous change in power from the periphery to the center of the lens, without a demarcation zone.

Bilateral implantation of AcrySof® IQ Vivity®: Patients will be implanted with AcrySof® IQ Vivity® during catarct surgery. The AcrySof® IQ Vivity® is a single-piece, hydrophobic acrylic IOL that utilizes non-diffractive wavefront-shaping technology (X-wave™) on its anterior surface to achieve an extended range of vision. Its aspheric anterior surface features a 2.2 mm central zone composed of two smooth transition elements: the first forms a slightly elevated plateau (\~1 µm) that stretches the wavefront, while the second shifts the wavefront to create a negative extended focal range. Together, these elements could create advanced and delayed wavefronts resulting in a continuous extended focal range instead of multiple focal points, while optimizing light transmission. This UV-absorbing and blue light filtering foldable IOL has a refractive index of 1.55 at 35 °C, an optic diameter of 6 mm and an overall length of 13 mm. The lens is available in spherical powers ranging from +10.0 to +30.0 diopters.

Bilateral implantation of LuxSmart™: Patients will be implanted with LuxSmart™ during catarct surgery. The LuxSmart™ intraocular lens is a single-piece, acrylic hydrophobic and aspheric IOL with an overall diameter of 11 mm, an optical diameter of 6 mm, and a 4-point fixation haptic design. This non-diffractive IOL utilizes a technology known as Pure Refractive Optics (PRO), incorporating a 2.0 mm central EDOF zone that combines fourth- and sixth-order spherical aberrations of opposite signs designed to improve perceived depth of focus. The paracentral region, on the other hand, is a transition zone meant to gradually decrease the optic vergence from the center to the monofocal periphery. It has also a 360° continuous square edge on the posterior surface to prevent epithelial lens cells migration and posterior capsule opacification.

Bilateral implantation of Eyecryl SERT: Patients will be implanted with Eyecryl SERT during catarct surgery. EyeCryl-SERT (Biotech) is a new advanced monofocal, single-piece hydrophobic IOL with an aspheric surface, continuous vision from distance to intermediate, spectacle independence for intermediate vision, an extended range of vision: \>1.75 D at spectacle plane with visual acuity 0.2 LogMAR or better, an intermediate vision up to 57 cm and a design for fast neural adaptation.

Bilateral implantation of RayOne EMV: Patients will be implanted with RayOne EMV during catarct surgery. RayOne EMV (Rayner) is a new EDOF lens that has recently emerged in the market. It is a truly non-diffractive, single-piece hydrophilic IOL which does not use light splitting technology like many IOLs which increase depth of focus, resulting in low levels of dysphotopsia, similar to standard monofocal lenses. RayOne EMV is the only patented aspheric IOL that induces controlled positive spherical aberration. Compared to a lens with zero spherical aberration, the carefully controlled positive spherical aberration induced by RayOne EMV spreads light along the visual axis, elongating the focal range from far into intermediate with up to 1.5 D of depth of focus (per lens on the spectacle plane).

Study summary

Study Goal

The goal of this clinical trial is to compare how well four different types of artificial lenses (called intraocular lenses or IOLs) help people see after cataract surgery. The main questions it aims to answer are:

Which lens gives the best vision at different distances (far, middle, and close)? How satisfied are patients with their vision after surgery? How often do patients still need glasses after surgery?

Who Can Participate Adults aged 22 to 85 years who need cataract surgery in both eyes and meet specific health requirements.

Study Design

Researchers compared six different lens types:

TECNIS Eyhance - designed to improve middle-distance vision AcrySof IQ Vivity - extends the range of clear vision LuxSmart - uses special optics for better depth of focus Rayner EMV - uses gradual light-bending technology for smooth vision transition Eycryl SERT - modifies light focus to extend clear vision range CT ASPHINA 409M - standard single-focus lens (comparison group)

Participants chose their preferred lens type after learning about each option's benefits and limitations.

What Participants Do? Participants will:

Have cataract surgery on both eyes (1-2 weeks apart) Complete vision tests at multiple distances Take contrast sensitivity tests under different lighting conditions Fill out questionnaires about vision quality and daily activities Attend follow-up visits at 1 day, 1 week, 1 month, and 3 months

This study helps patients and doctors make informed decisions about which type of artificial lens might work best for individual needs and lifestyle.

Eligibility

Sex
ALL
Min age
22 Years
Max age
85 Years
Healthy volunteers
No
Inclusion Criteria: * Bilateral implantation of the same intraocular lens (IOL) model * Expected postoperative best-corrected distance visual acuity (BCDVA) of 0.8 (decimal) or better * Regular corneal astigmatism less than 1 diopter Exclusion Criteria: * Endothelial cell density \< 2,000 cells/mm² * Required IOL power for emmetropia falls outside the available range of +10.0 D to +30.0 D * Pupillary abnormalities * Intraocular inflammation * Recent ocular trauma or ocular surgery that is unresolved/unstable, or which may impair visual outcomes or increase patient risk * History of corneal refractive surgery (e.g., LASIK, LASEK, PRK) * Irregular astigmatism, as well as corneal abnormalities or opacities * Conditions associated with an increased risk of zonular rupture, including capsular or zonular anomalies that may lead to IOL decentration or tilt, such as pseudoexfoliation syndrome, trauma, Marfan syndrome, among others * Systemic or ocular diseases, or medications, that may impair vision, increase surgical risk, or confound study outcomes * Clinically significant dry eye disease affecting visual function * Anticipated need for retinal laser treatment or any other ocular surgical intervention during the study period * Pregnancy, planned pregnancy, breastfeeding, or any condition associated with hormonal fluctuations that may induce refractive changes * Continuous contact lens wear within the past 4 weeks * Inability to understand and/or complete study questionnaires * Advanced glaucoma with visual field defects * Age-related macular degeneration (exudative or geographic form)

Primary outcome measure(s)

  • Distance-Corrected Intermediate Visual Acuity at 80cm (Unit: LogMAR) — From enrollment to the end of 3-month follow-up
    Monocular and binocular measurements of distance-corrected intermediate visual acuity (DCIVA) at 80cm in LogMAR.
  • Distance-Corrected Intermediate Visual Acuity at 60cm (Unit: LogMAR) — From enrollment to the end of 3-month follow-up
    Monocular and binocular measurements of distance-corrected intermediate visual acuity (DCIVA) at 60cm in LogMAR.
  • Binocular Defocus Curve (Unit: LogMAR) — From enrollment to the end of 3-month follow-up
    Following subjective refraction and determination of BCDVA, binocular defocus curve testing will be performed to evaluate the visual performance by adding defocus lenses from + 1.50 D to - 2.50 D in a randomized order.
  • BInocular depth of Focus at 0.1 LogMAR threshold (Unit: Diopters) — From enrollment to the end of 3-month follow-up
    In order to comply with the recommendations of the American National Standards Institute (ANSI) Z80.35-2018 guideline regarding the definition of the EDOF IOLs, the binocular depth of focus will be calculated from the binocular defocus curve at 0.1 LogMAR threshold.
  • Binocular Contrast Sensitivity Function (Unit: Log units) — From enrollment to the end of the 3-month follow-up
    Using the Functional Vision Analyzer (Optec 6500, Stereo Optical Co., Chicago, IL, USA) across five spatial frequencies (1.5, 3.0, 6.0, 12.0, and 18.0 cycles per degree) under three standardized lighting conditions (photopic, mesopic, mesopic with glare).
  • Vision-related quality of life (Unit: Points on 0-100 scale) — From enrollment to the end of 3-month follow-up
    Using the validated Visual Function Index-14 (VF-14) questionnaire.
  • Visual symptoms and their impact on daily life (Unit: QoV score 0-100) — From enrollment to the end of 3-month follow-up
    Using the validated McAlinden's Quality of Vision questionnaire.

Trial sites (1)

FacilityCityRegionStatus
Augenklinik Ahaus Ahaus North Rhine-Westphalia Recruiting
Official registry record

This page summarises publicly available registry data for informational purposes — not medical advice. Eligibility is determined by each study team; patients should discuss participation with their clinician.

View NCT07051720 on ClinicalTrials.gov ↗ ← All trials in Germany