Astellas Expands Its 330 Million Euro Tralee Biopharma Facility with a Second Aseptic Filling Line to Double Drug-Product Capacity Xeolas Pharmaceuticals Opens 158,000 Sq Ft State-of-the-Art Baldoyle Facility to Scale Specialty Medicine Manufacturing Priya Life Science Partners with Fleming for the 9th Annual Corporate Compliance & Transparency in Life Sciences Summit in Zurich Ireland Has the Capital and the Lessons: Digital Project Management Is How They Become Delivery Dunbar Pharma Brings First Plant-Derived Dronabinol API to UK Market Through IPS Pharma Leveraging Priya Life Science as a Data Tracker: The Ultimate Use Case & Career Guide The €100K Reality Check: Why a Six-Figure Pharma Salary in Ireland Feels Different Than in Switzerland or Germany Ireland's €93.8 Billion Non-EU Pharma Export Engine: Trade Data, Destination Markets, and Economic Impact Astellas Expands Its 330 Million Euro Tralee Biopharma Facility with a Second Aseptic Filling Line to Double Drug-Product Capacity Xeolas Pharmaceuticals Opens 158,000 Sq Ft State-of-the-Art Baldoyle Facility to Scale Specialty Medicine Manufacturing Priya Life Science Partners with Fleming for the 9th Annual Corporate Compliance & Transparency in Life Sciences Summit in Zurich Ireland Has the Capital and the Lessons: Digital Project Management Is How They Become Delivery Dunbar Pharma Brings First Plant-Derived Dronabinol API to UK Market Through IPS Pharma Leveraging Priya Life Science as a Data Tracker: The Ultimate Use Case & Career Guide The €100K Reality Check: Why a Six-Figure Pharma Salary in Ireland Feels Different Than in Switzerland or Germany Ireland's €93.8 Billion Non-EU Pharma Export Engine: Trade Data, Destination Markets, and Economic Impact
Active, not recruiting Not applicable

Continuous Glucose Monitoring in Intensive Care Unit

NCT05585801 · tracked via the Priya Life Science Czechia tracker
Phase
Not applicable
Started
2022-11-01
Last updated
2026-06-23

Condition(s) studied

Blood GlucoseCritical Care

Investigational drug(s) / intervention(s)

Dexcom G6 continuous glucose monitorBlood glucose measurements according to standards of care

Dexcom G6 continuous glucose monitor: Continuous glucose monitor will be used to measure interstitial glucose and aid in guiding the insulin therapy to achieve target blood glucose range of 6-10 mmol/l. In the control group, blood glucose will be measured according to standards of care and a blinded continuous monitor will be used to compare the time i range between the arms.

Blood glucose measurements according to standards of care: Blood glucose will be measured using point of care glucose meter and standard biochemistry methods. Blinded CGM will be applied to obtain continuous glucose values for post-hoc comparison.

Study summary

Glucose control in ICU patients is challenging and exerts high burden on the nursing staff. Continuous glucose monitors (CGM) are now approved and widely available in the outpatient setting for patients with diabetes mellitus. However, only minimal evidence on CGM performance, reliability and benefit in achieving desired glucose control in the intensive care setting has been gathered so far.

The objective of this study is to assess whether the use of CGM helps to maintain blood glucose levels within the time in range recommended for patients in the intensive care.

In addition, accuracy of the sensor will be evaluated and compared to measurements of blood glucose by standardized biochemistry methods.

Eligibility

Sex
ALL
Min age
18 Years
Max age
80 Years
Healthy volunteers
No
Inclusion Criteria: 1. Male or female patients, of 18 to 80 years of age, undergoing one of the following surgical procedures and post-operative care at ICU: 1. pancreas surgery - total or partial pancreas resection 2. orthotopic liver transplantation 3. simultaneous pancreas and kidney transplantation 4. patients with diabetes mellitus undergoing major surgery 2. Patient must have signed the Patient Informed Consent Form. Exclusion Criteria: Any criteria that would disable surgical procedures involved

Primary outcome measure(s)

  • Time in target range of 6-10 mmol/l — From the time of continuous glucose sensor insertion, which will be performed after admission to postoperative ICU, until the discharge from postoperative ICU, approx. 5-7 days