Impact of Allometric Pacing Rate on Ventricular Diastolic Function and Cerebral Blood Flow in Hypertensive Patients With Sinus Node Dysfunction
Condition(s) studied
Investigational drug(s) / intervention(s)
Personalized lower rate pacing: The intervention consists of programming the pacemaker lower rate to a personalized setting of 75 beats per minute (personalized lower rate, PLR), based on clinical assessment. The control condition uses the standard pacemaker lower rate programmed at 50-60 beats per minute. No additional procedures beyond routine clinical practice are introduced.
Standard lower rate pacing: The control intervention consists of programming the pacemaker lower rate to the standard clinical setting of 50-60 beats per minute, according to routine clinical practice. No additional procedures or deviations from standard care are introduced.
Study summary
The study is a prospective, randomized controlled study in hypertensive patients with a bradycardia indications for pacing therapy and a plan to receive dual-chamber pacemaker. Enrolled patients will be randomized 1:1 into the control group and the allometric-pace group. In the control group, the pacing lower rate will be set to the nominal 60 bpm post a dual-chamber pacemaker implantation as frequently used in clinical practice, while in the allometric-pace group, the pacing rate will be programmed at 75 bpm based on the estimation for Chinese population with a height of 165-170 cm (also called personalized lower rate) or based on the symptom-relief per clinical assessment by the study physicians. Each patient will undergo baseline assessments and 3-month follow-up visits. At the enrollment and office visits, each patient will undergo arterial blood pressure measurement, cardiac functional assessment and cerebral blood flow measurement. At the end of the study, the study physician will adjust pacing lower rate based on patients' conditions and clinical assessments. After the completion of the study, all patients will have regular device follow-up visit, usually 6-month interval or annually.
Each patient will receive the following major assessments: device performance and pacing percentages, ventricular diastolic function by doppler and echocardiography of LVEF, LVEDV, LVESV, stroke volume, cardiac output, arterial blood pressure measurements, cerebral blood flow by MRI or Echo (which one will be determined later by the study PIs), and Mini-Mental State Examination (MMSE).
Eligibility
Primary outcome measure(s)
- Change in Ventricular Diastolic Function and Cerebral Blood Flow — Baseline to 6 months post-implantation
In hypertensive patients with sinus node dysfunction treated with dual chamber pacemaker implantation, compared with the control group (pacemaker lower rate 50-60 bpm), to verify whether ventricular diastolic function and cerebral blood flow can be improved by personalized lower rate pacing (PLR) (75 bpm).
Trial sites (1)
| Facility | City | Region | Status |
|---|---|---|---|
| Shanxi Cardiovascular Hospital | Taiyuan | Shanxi | Recruiting |
More Medtronic Cardiac Rhythm and Heart Failure trials in China
Other trials for the same condition
This page summarises publicly available registry data for informational purposes — not medical advice. Eligibility is determined by each study team; patients should discuss participation with their clinician.