Ireland
--:--IST
Latest
Astellas Expands Its 330 Million Euro Tralee Biopharma Facility with a Second Aseptic Filling Line to Double Drug-Product Capacity Xeolas Pharmaceuticals Opens 158,000 Sq Ft State-of-the-Art Baldoyle Facility to Scale Specialty Medicine Manufacturing Priya Life Science Partners with Fleming for the 9th Annual Corporate Compliance & Transparency in Life Sciences Summit in Zurich Ireland Has the Capital and the Lessons: Digital Project Management Is How They Become Delivery Dunbar Pharma Brings First Plant-Derived Dronabinol API to UK Market Through IPS Pharma Leveraging Priya Life Science as a Data Tracker: The Ultimate Use Case & Career Guide The €100K Reality Check: Why a Six-Figure Pharma Salary in Ireland Feels Different Than in Switzerland or Germany Ireland's €93.8 Billion Non-EU Pharma Export Engine: Trade Data, Destination Markets, and Economic Impact Astellas Expands Its 330 Million Euro Tralee Biopharma Facility with a Second Aseptic Filling Line to Double Drug-Product Capacity Xeolas Pharmaceuticals Opens 158,000 Sq Ft State-of-the-Art Baldoyle Facility to Scale Specialty Medicine Manufacturing Priya Life Science Partners with Fleming for the 9th Annual Corporate Compliance & Transparency in Life Sciences Summit in Zurich Ireland Has the Capital and the Lessons: Digital Project Management Is How They Become Delivery Dunbar Pharma Brings First Plant-Derived Dronabinol API to UK Market Through IPS Pharma Leveraging Priya Life Science as a Data Tracker: The Ultimate Use Case & Career Guide The €100K Reality Check: Why a Six-Figure Pharma Salary in Ireland Feels Different Than in Switzerland or Germany Ireland's €93.8 Billion Non-EU Pharma Export Engine: Trade Data, Destination Markets, and Economic Impact
Starting soon Not applicable

A Clinical Trial Assessing the Safety and Effectiveness of Orthokeratology Lenses in Patients With Myopia and Myopic Astigmatism

NCT07047924 · tracked via the Priya Life Science Australia tracker
Sponsor
Menicon Co., Ltd
Phase
Not applicable
Started
2025-07-01
Last updated
2025-07-02

Condition(s) studied

MyopiaMyopic Astigmatism

Investigational drug(s) / intervention(s)

MCOK-01

MCOK-01: The investigational device is a Rigid Gas Permeable contact lenses for orthokeratology. MCOK-01 applied the reverse geometry design and adopted the lens material which possesses the highest oxygen permeability among all the materials for orthokeratology lens.

Study summary

This is a prospective, multi-centre, single-arm clinical trial to evaluate the effectiveness and safety of MCOK-01 lenses in patients with myopia and myopic astigmatism who need dioptric correction.

A maximum number of 220 participants are planned to be enrolled , with a minimum of 150 planned to complete the trial (30% dropout). All participants will be enrolled in Australia.

Enrolled participants will wear the lenses every night for up to 12 months, removing them upon waking. 8 follow up visits will be completed during treatment, after: 1 day, 1 week, 2 weeks, 1 month, 3 months, 6 months, 9 months and 12 months of wearing the lenses.

Eligibility

Sex
ALL
Min age
6 Years
Max age
40 Years
Healthy volunteers
No
Inclusion Criteria: 1. Participant diagnosed with myopia and myopic astigmatism, documented by an eye care practitioner. 2. Participant is between 6-40 years old inclusive. 3. Participant is not motivated to wear glasses in daily life. 4. Participants are of Caucasian ethnicity (must be \>50% of study population) or other non-east Asian ethnic groups (Indian, Sri-Lankan, Pakistani, etc). Neither parent of participant can be east-asian. 5. Provision of written informed consent. 6. Participants understand and agree to all requirements of the clinical trial; visit schedule, investigator guidance, follow-lens instructions, etc Exclusion Criteria: 1. Best corrected distance vision acuity of less than 0.8 with spectacles. 2. Subjective refraction test shows spherical power greater than -6.00D,less than -0.50D or astigmatism greater than 1.5D. 3. Participants of East-Asian ethnicity (Chinese, Japanese, Korean, etc). 4. Participants requiring treatment for eye disease other than refractive error (excluding those receiving artificial tears eye drops due to the wearing of corneal contact lenses). 5. Medical history of intraocular surgery that may affect the effect of wearing the lens for this clinical trial (those with corneal transplantation, Retinal detachment, etc).. 6. Medical history of refractive corneal surgery. 7. Slit lamp findings that are more serious than grade 1 8. Participants requiring lens parameters outside of the scope of lens for this clinical trial. 9. Known eye allergies or conditions that are contraindicated, including sensitivity to any lens care maintenance or packaging solution additives being used in this study 10. Corneal abnormalities including keratoconus, corneal dystrophy and/or previous history of ocular herpes infections. 11. Currently using Atropine, or have used Atropine eye drops 14 days prior to enrolment. 12. For female participants, pregnancy, planned pregnancy during the trial or breastfeeding (pregnancy status provided by verbal confirmation). 13. Participation in other clinical trials or participation within the past 30 days. 14. Use of orthokeratology lenses within the prior 90 days, extended wear, rigid gas permeable corneal and scleral lenses within the prior 30 days, daily disposable and daily wear within the prior 15 days. 15. Mental incapacity. 16. Other Participants deemed not suitable for the trial at the investigator's discretion

Primary outcome measure(s)

  • Lines of improvement of monocular uncorrected distance visual acuity — 12-months following enrolment
    Reading of a logMAR chart. Each line difference represents 0.1 logMAR acuity. The improvement in acuity is represented by a numerical reduction in the logMAR value.
  • Proportion of eyes achieved uncorrected distance visual acuity of ≤0.30 logMAR, ≤0.20 logMAR, ≤0.10 logMAR, and ≤0.00 logMAR — 1 month, 3 months, 6 months, 9 months, and 12 months following enrolment
    Measured using a logMAR chart. Each line difference represents 0.1 logMAR acuity. The improvement in acuity is represented by a numerical reduction in the logMAR value.
  • A level of attempted versus achieved reduction in manifest refractive error — 12 months following enrolment
    Using a Phoropter/Refractor. Proportion of eyes with manifest sphere within ±0.50 D, ±1.00 D, and ±2.00 D of the target (plano)
  • Number and rates (by type of event and relation to device) of serious and significant adverse events — Any time within the 12-months enrolment window
    Adverse events will be self-reported by participants to investigative team
  • Number and rates (by type of event) of all types of adverse events that were not classified as serious or significant adverse events. — Any time within the 12-months enrolment window
    Adverse events will be self-reported by participants to investigative team
  • Number of slit lamp results above grade 2 — 1 day, 1 week, 2 weeks, 1 month, 3 months, 6 months, 9 months, and 12 months following enrolment
    Assessed using a slit lamp
  • Number and rate of cases of loss of; monocular best spectacle corrected visual acuity (BSCVA) of 2 or more lines (≥ 0.2 logMar), and 1 or more lines (≥ 0.1 logMar). — 1 day, 1 week, 2 weeks, 1 month, 3 months, 6 months, 9 months, and 12 months following enrolment
    Assessed with a logMAR chart

Trial sites (4)

FacilityCityRegionStatus
Eyecare Kids Hillsdale New South Wales
UNSW School of Optometry and Vision Science Sydney New South Wales
Queensland University of Technology Optometry and Vision Science Kelvin Grove Queensland
The University of Melbourne Department of Optometry and Vision Sciences Carlton Victoria
Official registry record

This page summarises publicly available registry data for informational purposes — not medical advice. Eligibility is determined by each study team; patients should discuss participation with their clinician.

View NCT07047924 on ClinicalTrials.gov ↗ ← All trials in Australia