Ireland
--:--IST
Latest
Astellas Expands Its 330 Million Euro Tralee Biopharma Facility with a Second Aseptic Filling Line to Double Drug-Product Capacity Xeolas Pharmaceuticals Opens 158,000 Sq Ft State-of-the-Art Baldoyle Facility to Scale Specialty Medicine Manufacturing Priya Life Science Partners with Fleming for the 9th Annual Corporate Compliance & Transparency in Life Sciences Summit in Zurich Ireland Has the Capital and the Lessons: Digital Project Management Is How They Become Delivery Dunbar Pharma Brings First Plant-Derived Dronabinol API to UK Market Through IPS Pharma Leveraging Priya Life Science as a Data Tracker: The Ultimate Use Case & Career Guide The €100K Reality Check: Why a Six-Figure Pharma Salary in Ireland Feels Different Than in Switzerland or Germany Ireland's €93.8 Billion Non-EU Pharma Export Engine: Trade Data, Destination Markets, and Economic Impact Astellas Expands Its 330 Million Euro Tralee Biopharma Facility with a Second Aseptic Filling Line to Double Drug-Product Capacity Xeolas Pharmaceuticals Opens 158,000 Sq Ft State-of-the-Art Baldoyle Facility to Scale Specialty Medicine Manufacturing Priya Life Science Partners with Fleming for the 9th Annual Corporate Compliance & Transparency in Life Sciences Summit in Zurich Ireland Has the Capital and the Lessons: Digital Project Management Is How They Become Delivery Dunbar Pharma Brings First Plant-Derived Dronabinol API to UK Market Through IPS Pharma Leveraging Priya Life Science as a Data Tracker: The Ultimate Use Case & Career Guide The €100K Reality Check: Why a Six-Figure Pharma Salary in Ireland Feels Different Than in Switzerland or Germany Ireland's €93.8 Billion Non-EU Pharma Export Engine: Trade Data, Destination Markets, and Economic Impact
Active, not recruiting Not applicable

Acuity 200™ (Fluoroxyfocon A) Orthokeratology Contact Lens for Overnight Wear

NCT06009458 · tracked via the Priya Life Science Australia tracker
Sponsor
Acuity Polymers, Inc
Phase
Not applicable
Started
2023-10-01
Last updated
2025-01-14

Condition(s) studied

Myopia

Investigational drug(s) / intervention(s)

Acuity 200™ (fluoroxyfocon A) Orthokeratology Contact Lens for Overnight Wear

Acuity 200™ (fluoroxyfocon A) Orthokeratology Contact Lens for Overnight Wear: Acuity 200™ Orthokeratology Contact Lenses are intended to be worn overnight with removal during following day. The lenses are designed to produce a temporary reduction of myopia by reversibly altering the curvature of the cornea. The lenses are manufactured from fluoroxyfocon A, which is a gas permeable contact lens material composed of a siloxanyl fluoromethacrylate copolymer. The material name fluoroxyfocon A is registered with United States Adopted Name (USAN).The Acuity 200™ (fluoroxyfocon A) Orthokeratology Contact Lens is available in spherical, asymmetrical, aspheric, and tangential lens designs to best fit the individual cornea, using corneal topography and/or diagnostic lenses.

Study summary

The objective of this clinical investigation is to collect scientifically valid safety and effectiveness data on the Acuity 200™ (fluoroxyfocon A) Orthokeratology Contact Lens for Overnight Wear. The clinical performance data reported from this study is intended to be submitted to the U.S. Food and Drug Administration Center for Devices and Radiological Health (CDRH) in support of a new Premarket Application (PMA).

Eligibility

Sex
ALL
Min age
7 Years
Max age
—
Healthy volunteers
No
Inclusion Criteria: 1. Is age 7 or older with full legal capacity to volunteer or has parental or legal guardian written approval to volunteer; and has read, understood and signed the Informed Consent Form or Assent Form (for subjects 18 years and under); 2. Is willing and able to follow participant instructions for product usage and meet the specified schedule of follow-up visits; 3. Has naturally occurring refractive myopia from -0.75 to -6.00 diopters sphere (spectacle plane), with refractive astigmatism (spectacle plane) up to 1.75 DC-as determined by adjusted manifest refraction (phoropter or trial frame) with a 12.5 mm vertex distance. 4. Has a best spectacle corrected visual acuity of 0.04 log MAR (20/20 -2) or better in each eye; 5. Is free of eye disease and binocular vision problems (e.g., strabismus, amblyopia, oculomotor nerve palsies, corneal disease, etc.) that may affect vision or contact lens wear; Has normal healthy eyes with no evidence of lid infection or structural abnormality; a conjunctiva free of infection; a cornea clear and free of edema, visually or topographically significant scars, clinically significant staining, significant vascularization, infiltrates when examined by slit-lamp biomicroscopy; and no evidence of iritis or uveitis. Exclusion Criteria: 1. Is pregnant, breast-feeding or intends to become pregnant over the course of the study. 2. Is a potential pediatric subject that does not have the appropriate level of psychological maturity to comply with appropriate procedures needed for safe wear according to the investigator. 3. Is a potential pediatric subject that is a ward of the State or any other agency, institution, or entity. 4. Has a history of any of the following medical conditions: collagen vascular disease, autoimmune disease, immunodeficiency diseases, ocular herpes zoster or simplex, endocrine disorders (including, but not limited to active thyroid disorders and diabetes), lupus, and rheumatoid arthritis. NOTE: The presence of diabetes (either type 1 or 2), regardless of disease duration, severity or control, specifically excludes subjects from eligibility. 5. Has a history of intraocular or corneal surgery (including cataract extraction and refractive surgery-such as Lasik), active ophthalmic disease or abnormality (including, but not limited to, blepharitis, recurrent corneal erosion, dry eye syndrome, neovascularization \> 1mm from limbus), clinically significant lens opacity, clinical evidence of trauma (including scarring), or with evidence of glaucoma or propensity for narrow angle glaucoma as determined by gonioscopic examination in either eye. NOTE: This includes any subject with open angle glaucoma, regardless of medication regimen or control. Additionally, any subject with an IOP greater than 21 mm Hg at baseline is specifically excluded from eligibility. 6. Has evidence of keratoconus, corneal irregularity, or abnormal video-keratography in either eye. 7. Has a pupil size greater than 6.0 mm in photopic illumination as measured with pupil detection component of computer assisted video keratography. 8. Has a corneal diameter of 10 mm or less; 9. Has flat keratometry values flatter than 38.00D (8.88 mm), or steeper than 47.00D (7.16 mm); 10. Takes medication that may cause dry eye or affect vision, corneal curvature, or healing (i.e., corticosteroids); 11. Has an allergy to any ingredient in the study lens care solutions; 12. Has significant ocular allergy, which would contraindicate solution use and/or "normal" contact lens wear; 13. Is currently using or has a history of atropine use for myopia progression control 14. Is a current wearer or previous wearer within the last 90 days of daily wear rigid gas permeable contact lenses, extended wear rigid gas permeable contact lenses, or orthokeratology contact lenses; 15. Is participating in any other type of clinical or research study.

Primary outcome measure(s)

  • Lines of improvement of monocular UCVA at the 12-month visit (overall and stratified by baseline sphere) — 1 year
    The number of lines of change in acuity (for an eye) is defined as the difference in the logMAR acuities, scored to the letter, multiplied by 10. Each line difference represents 0.1 logMAR acuity. The improvement in acuity is represented by a numerical reduction in the logMAR value. The primary effectiveness endpoints described above will also be stratified by subjects' baseline age (including 7 to 11 years (children), 12 to 21 years (adolescents), and 22 years and older (adults) .
  • Attempted vs. Achieved Reduction in manifest refractive error — 1 Year
    proportion of eyes with manifest sphere within ±0.50 D, ±1.00 D, and ±2.00 D of the target (plano) at the 12-month post-dispensing visit (overall and stratified by baseline sphere). The primary effectiveness endpoints described above will also be stratified by subjects' baseline age (including 7 to 11 years (children), 12 to 21 years (adolescents), and 22 years and older (adults) .
  • Proportion of eyes achieved UCVA of ≤0.30 logMAR , ≤0.20 logMAR ,≤0.10 logMAR, and ≤0.00 logMAR — 1 Year
    Proportion of eyes at the 1-month visit (and later visit intervals) that have achieved UCVA of ≤0.30 logMAR, ≤0.20 logMAR, ≤0.10 logMAR, and ≤0.00 logMAR for the whole cohort and stratified by pre-treatment refractive bin. The primary effectiveness endpoints described above will also be stratified by subjects' baseline age (including 7 to 11 years (children), 12 to 21 years (adolescents), and22 years and older (adults) .
  • Treatment stability — 1 Year
    Treatment stability as measured by the percentage of eyes that change by less than ±0.50 diopters manifest refraction spherical equivalent (MRSE) between two consecutive visits (baseline and 1-month, 1 and 3-month, 3 and 6-month, 6 and 9-month, and 9 and 12-month) The primary effectiveness endpoints described above will also be stratified by subjects' baseline age (including 7 to 11 years (children), 12 to 21 years (adolescents), and 22 years and older (adults) .
  • Number and rates (by type of event and relation to device) of serious and significant adverse events occurred at any visit — 1 Year
    Number and rates (by type of event and relation to device) of serious and significant adverse events occurred at any visit. The primary safety endpoints described above will also be stratified by subjects' baseline age (including 7 to 11 years (children), 12 to 21 years (adolescents), and 22 years and older (adults).
  • Number and rates (by type of event) of all types of adverse events that were not classified as serious or significant adverse events. — 1 Year
    Number and rates (by type of event) of all types of adverse events that were not classified as serious or significant adverse events. The primary safety endpoints described above will also be stratified by subjects' baseline age (including 7 to 11 years (children), 12 to 21 years (adolescents), and 22 years and older (adults).
  • All slit lamp results will be tabulated and findings above grade 2 will be evaluated and explained in relation to the treatment — 1 Year
    All slit lamp results will be tabulated and findings above grade 2 will be evaluated and explained in relation to the treatment. The primary safety endpoints described above will also be stratified by subjects' baseline age (including 7 to 11 years (children), 12 to 21 years (adolescents), and 22 years and older (adults).
  • Number and rate of cases of loss from baseline to any post-dispensing visit of: monocular best spectacle corrected visual acuity (BSCVA) of 2 or more lines (≥ 0.2 logMar), and 1 or more lines (≥ 0.1 logMar). — 1 Year
    Number and rate of cases of loss from baseline to any post-dispensing visit of: monocular best spectacle corrected visual acuity (BSCVA) of 2 or more lines (≥ 0.2 logMar), and 1 or more lines (≥ 0.1 logMar). The primary safety endpoints described above will also be stratified by subjects' baseline age (including 7 to 11 years (children), 12 to 21 years (adolescents), and 22 years and older (adults).

Trial sites (13)

FacilityCityRegionStatus
Advanced Optometry of Mission Viejo Mission Viejo California
Elsa Pao, O.D. Optometrist Oakland California
Pacific Rims Optometry San Francisco California
Silicon Valley Eye Physicians Sunnyvale California
Coan Eye Care Ocoee Florida
Center for Ophthalmic and Vision Research, LLC New York New York
Reed Eye Associates Pittsford New York
Bellaire Family Eye Care Bellaire Texas
Queenston Eye Care Houston Texas
Innovative Eye Care Adelaide Australia
Custom Eyecare Newcastle Cooks Hill Australia
Eyeconic Optometry Southport Australia
Rose Optometry Hamilton New Zealand
Official registry record

This page summarises publicly available registry data for informational purposes — not medical advice. Eligibility is determined by each study team; patients should discuss participation with their clinician.

View NCT06009458 on ClinicalTrials.gov ↗ ← All trials in Australia