Feasibility Study of Non-Contact Imaging-Based Physiological Monitoring in the Operating Room
Condition(s) studied
Investigational drug(s) / intervention(s)
Non-contact rPPG software: A non-invasive, video-based software utilizing remote Photoplethysmography (rPPG) technology to estimate heart rate, blood pressure, and SpO2 by analyzing facial video captured via camera-enabled devices.
Study summary
This study aims to evaluate the feasibility and accuracy of a non-contact, camera-based physiological monitoring technology in a perioperative setting (including anesthesia induction, surgery, and recovery).Conventional vital sign monitoring tools-such as ECG leads, blood pressure cuffs, and pulse oximeters-require direct skin contact, which may pose risks of cross-infection or skin injury in vulnerable populations (e.g., newborns or elderly patients). This research utilizes remote Photoplethysmography (rPPG) technology to estimate vital signs, including heart rate, blood pressure, and blood oxygen saturation (SpO2), by analyzing facial video captured via standard camera devices (Logitech C930, iPhone 16 Pro Max, and Samsung Galaxy S24 Ultra).The primary goal is to assess the consistency and stability of this non-contact system compared to clinical gold-standard monitors (Masimo Root, SedLine O3, and Radical-7) during actual surgical procedures. The findings will serve as a foundation for developing non-invasive, supplementary monitoring tools in dynamic clinical environments.
Eligibility
Primary outcome measure(s)
- Accuracy of Heart Rate (HR) monitoring — From anesthesia induction to recovery (approximately 2-6 hours).
The success rate of non-contact HR measurement using the rPPG software compared to the reference values from the Masimo Root clinical monitoring platform. A "success" is defined as an absolute error within +/- 3 bpm. Unit of Measure: Percentage of successful measurements (%) - Success rate of Systolic Blood Pressure (SBP) monitoring — From anesthesia induction to recovery (approximately 2-6 hours).
The success rate of non-contact SBP measurement compared to the reference values from the Masimo Root platform. A "success" is defined as an absolute error within +/- 12 mmHg. Unit of Measure: Percentage of successful measurements (%) - Success rate of Diastolic Blood Pressure (DBP) monitoring — From anesthesia induction to recovery (approximately 2-6 hours).
The success rate of non-contact DBP measurement compared to the reference values from the Masimo Root platform. A "success" is defined as an absolute error within +/- 10 mmHg. Unit of Measure: Percentage of successful measurements (%) - Success rate of Oxygen Saturation (SpO2) monitoring — From anesthesia induction to recovery (approximately 2-6 hours).
The success rate of non-contact SpO2 measurement compared to the reference values from the Masimo Root platform. A "success" is defined as an absolute error within +/- 8% (when SpO2 \>/= 80%) or +/- 15% (when SpO2 \< 80%). Unit of Measure: Percentage of successful measurements (%)
Trial sites (1)
| Facility | City | Region | Status |
|---|---|---|---|
| Department of Anesthesiology, Taipei Veterans General Hospital | Taipei | Taiwan | Recruiting |
More Taipei Veterans General Hospital, Taiwan trials in Taiwan
Other trials for the same condition
This page summarises publicly available registry data for informational purposes — not medical advice. Eligibility is determined by each study team; patients should discuss participation with their clinician.