Recruiting
Not applicable
LUMENS-1 EU EFS CIP
Condition(s) studied
Aneurysm CerebralBifurcationUnruptured Intracranial AneurysmSaccular AneurysmBrain Aneurysm
Investigational drug(s) / intervention(s)
LuSeed Aneurysm Embolization System
LuSeed Aneurysm Embolization System: a permanent intrasaccular implant used for treatment of unruptured intracranial saccular aneurysms (IA) in adult patients according to international guidelines who are indicated for non-emergent endovascular embolization of saccular IAs at the time of presentation.
Study summary
The primary objective of this clinical investigation is to evaluate the early safety and feasibility of the LuSeed Aneurysm Embolization System for treating unruptured intracranial aneurysms (IA). This is a prospective, single-arm, open-label, multi-center, interventional study, screening patients approved for treatment of unruptured IAs based on national or international guidelines. Up to 30 eligible subjects meeting inclusion and exclusion criteria and providing consent will be enrolled across a maximum of 10 medical centers in the EU.
Eligibility
Inclusion Criteria:
* Patients indicated for treatment of unruptured intracranial aneurysms (IA) according to AHA / ASA Guidelines.
1. Age 18-80 years at screening
2. Patients who are suitable for non-emergency endovascular embolization of saccular IAs
3. The IA must have had the following characteristics:
* IA located in the anterior or posterior circulation
* IA dimensions appropriate for treatment with
LuSeed-Vascular Embolization Device per implant size selection guidelines as outlined in the Instructions for Use (IFU) and as follows:
* IA Width: 2.5-5.5\[mm\]
* IA Neck: 2.0-5.0\[mm\]
* IA Height: min 4.0 \[mm\]- device short configuration, min 5.0 \[mm\]-device long configuration 4. Patient is willing and able to participate in the study for the duration of the study follow-up and can comply with study requirements Exclusion Criteria: 5. Patient able to give their informed consent can be included in this study. Exclusion Criteria
1. Ruptured intracranial aneurysm
2. Patient anatomy or physiology considered unsuitable for endovascular treatment as determined by imaging Core Lab
3. Contraindication for arterial access
4. Intracranial aneurysm neck diameter less than 2mm or greater than 5 mm
5. Intracranial aneurysm sac diameter less than 2.5mm or greater than 5.5mm
6. Intracarnial aneurysm minimum hight less than 4.0 mm
7. Target Intracranial aneurysm contains other devices/implants (e.g., coils)
8. Stenosis of the target IA's parent vessel \>50%
9. Known allergy to platinum, nickel, or titanium
10. Known allergy to contrast agents
11. Absolute contraindication to anticoagulation or antiplatelet therapy
12. Anticoagulation medications such as warfarin that cannot be discontinued
13. Pregnant, breastfeeding or planning pregnancy within next 12 months
14. Acute or chronic renal failure (stage III or IV by VARC-3 criteria)
15. Cerebral embolism, stroke, or TIA in past 6 months
16. Myocardial infarction in the past 6 months
17. Any other medical issue within the brain that would preclude device implantation (such as brain surgery, radiation in the target area of intervention from an external beam source, acute traumatic craniocerebral injury, etc.)
18. Patient had any circulatory, neurovascular, cardiovascular, or neurologic conditions that resulted in unstable neurological symptoms at screening.
19. Patient had physical, neurologic or psychiatric conditions which precluded his/her ability to comply with all aspects of the screening, evaluation, treatment, and the postprocedure follow-up schedule.
20. Other medical conditions that cause an inability to comply with study requirements and/or that could increase the risk of neurovascular procedures (e.g., extreme frailty, liver failure, cancer, heart failure, chronic obstructive pulmonary disease, immunosuppression, neural disease, and hematologic disorders etc.)
21. Patient had a life expectancy of less than 12 months .
22. Current participation in another study with investigational devices or drugs that would confound the effect of the study outcomes.
Primary outcome measure(s)
- Primary Safety Endpoint — 30 Days Post Study Procedure
Death of any non-accidental cause, Procedure or Device Related Death or Any Major Disabling Stroke
\*An independent Medical Monitor (IMM) will adjudicate all data used for safety endpoint analyses
- Primary Feasibility Endpoint — Day 0
Technical Success as defined by:
1. Success in accessing target intracranial aneurysm (IA) with the LuSeed Aneurysm Embolization System
2. Successful visual confirmation of the LuSeed Aneurysm Embolization System Successful deployment and detachment of the LuSeed Aneurysm Embolization System
Trial sites (6)
| Facility | City | Region | Status |
| University Hospital St. Ivan Rilski |
Sofia |
Bulgaria |
Recruiting |
| The University Medical Center Hamburg-Eppendorf |
Hamburg |
Germany |
Recruiting |
| Sheba Medical Center |
Tel HaShomer |
Israel |
Recruiting |
| UCK Katowice |
Katowice |
Poland |
Recruiting |
| Norbert Barlicki Memorial Teaching Hospital No. 1 of the Medical University of Lodz |
Lodz |
Poland |
Recruiting |
| Jan Mikulicz-Radecki University Clinical Hospital in Wrocław |
Wroclaw |
Poland |
Not Yet Recruiting |