Ireland
--:--IST
Latest
Astellas Expands Its 330 Million Euro Tralee Biopharma Facility with a Second Aseptic Filling Line to Double Drug-Product Capacity Xeolas Pharmaceuticals Opens 158,000 Sq Ft State-of-the-Art Baldoyle Facility to Scale Specialty Medicine Manufacturing Priya Life Science Partners with Fleming for the 9th Annual Corporate Compliance & Transparency in Life Sciences Summit in Zurich Ireland Has the Capital and the Lessons: Digital Project Management Is How They Become Delivery Dunbar Pharma Brings First Plant-Derived Dronabinol API to UK Market Through IPS Pharma Leveraging Priya Life Science as a Data Tracker: The Ultimate Use Case & Career Guide The €100K Reality Check: Why a Six-Figure Pharma Salary in Ireland Feels Different Than in Switzerland or Germany Ireland's €93.8 Billion Non-EU Pharma Export Engine: Trade Data, Destination Markets, and Economic Impact Astellas Expands Its 330 Million Euro Tralee Biopharma Facility with a Second Aseptic Filling Line to Double Drug-Product Capacity Xeolas Pharmaceuticals Opens 158,000 Sq Ft State-of-the-Art Baldoyle Facility to Scale Specialty Medicine Manufacturing Priya Life Science Partners with Fleming for the 9th Annual Corporate Compliance & Transparency in Life Sciences Summit in Zurich Ireland Has the Capital and the Lessons: Digital Project Management Is How They Become Delivery Dunbar Pharma Brings First Plant-Derived Dronabinol API to UK Market Through IPS Pharma Leveraging Priya Life Science as a Data Tracker: The Ultimate Use Case & Career Guide The €100K Reality Check: Why a Six-Figure Pharma Salary in Ireland Feels Different Than in Switzerland or Germany Ireland's €93.8 Billion Non-EU Pharma Export Engine: Trade Data, Destination Markets, and Economic Impact
Recruiting Not applicable

HighFLO Study - HighLife Trans-septal Mitral Valve Replacement (TSMVR) Feasibility Study of the Open Cell CLARITY Valve

NCT04888247 · tracked via the Priya Life Science France tracker
Phase
Not applicable
Started
2021-07-01
Last updated
2024-10-03

Condition(s) studied

Mitral Regurgitation

Investigational drug(s) / intervention(s)

CLARITY

CLARITY: Trans-septal mitral valve replacement

Study summary

Feasibility, safety and performance of the HighLife CLARITY TSMV and its delivery system

Eligibility

Sex
ALL
Min age
18 Years
Max age
—
Healthy volunteers
No
Inclusion Criteria: 1. Age ≥ 18 years 2. Moderate-severe or severe mitral regurgitation (≥ 3+) 3. Patient has New York Heart Association (NYHA) Functional Class II, III or ambulatory IV 4. Patient is under guideline directed medical therapy for at least one month, as reviewed and confirmed by the local multidisciplinary Heart Team 5. Patient is high-risk for open-heart surgery based on the assessment of the multidisciplinary Heart Team using standard scoring systems and consideration of co-morbidities, frailty, and disability 6. Patient meets the anatomical criteria for HighLife valve 7. Patient is willing to participate in the study and provides signed informed consent 8. Patients with a high risk for LVOTO Exclusion Criteria: 1. Any stroke/TIA within 30 days 2. Severe symptomatic carotid stenosis (\> 70% by non-invasive imaging) 3. Active infections requiring antibiotic therapy 4. Active ulcer or gastro-intestinal bleeding in the past 3 months 5. History of bleeding diathesis, coagulopathy or refusal of future blood transfusion 6. Patients in whom TEE is not feasible 7. Patients who are pregnant or lactating, or plan to get pregnant in the next 12 months. 8. Patient is unable to comply with the follow-up schedule and assessments 9. Participation in another clinical investigation at the time of inclusion 10. Patient has known allergies to the device components or contrast medium 11. Patient cannot tolerate anticoagulation or antiplatelet therapy 12. Patients with a life expectancy of less than 12 months due to non-cardiac conditions 13. Patient had permanent pacemaker, or similar device with implantable cardiac leads (i.e. resynchronization therapy) within the last 3 months \-

Primary outcome measure(s)

  • Rate of subjects meeting Technical Success — 24 hours
    * Successful vascular access, delivery and retrieval of the HighLife delivery systems * Deployment and correct positioning of the HighLife 28mm CLARITY TSMV * Freedom from additional emergency surgery or re-intervention related to the device or access procedure, that occurred (was initiated) during the procedure. Any emergency surgery or re-intervention that occurs after the patient exits the procedure room/cath lab in stable condition will be captured as an AE/SAE * Successful vascular access, delivery and retrieval of the HighLife delivery systems * Deployment and correct positioning of the HighLife 28mm CLARITY TSMV * Freedom from additional emergency surgery or re-intervention related to the device or access procedure, that occurred (was initiated) during the procedure. Any emergency surgery or re-intervention that occurs after the patient exits the procedure room/cath lab in stable condition will be captured as an AE/SAE

Trial sites (14)

FacilityCityRegionStatus
Wesley Hospital Auchenflower Australia Recruiting
Mount Hospital Perth Australia Recruiting
Macquarie University Hospital Sydney Australia Terminated
AZ St. Jan - Brugge Bruges Belgium Recruiting
UZ Leuven Leuven Belgium Recruiting
CHU Lille Lille France Recruiting
Centre Hospitalo - Univ de Nantes Nantes France Recruiting
CHU de Rennes Rennes France Recruiting
Cliniue Pasteur Toulouse France Recruiting
Deutsches Herzzentrum Munchen Munich Germany Recruiting
University Hospital Ulm Ulm Germany Recruiting
Medical University of Silesia Katowice Poland Recruiting
Medical University of Warsaw Warsaw Poland Recruiting
Brighton and Sussex University Hospital Brighton United Kingdom Recruiting
Official registry record

This page summarises publicly available registry data for informational purposes — not medical advice. Eligibility is determined by each study team; patients should discuss participation with their clinician.

View NCT04888247 on ClinicalTrials.gov ↗ ← All trials in France