Ireland
--:--IST
Latest
Astellas Expands Its 330 Million Euro Tralee Biopharma Facility with a Second Aseptic Filling Line to Double Drug-Product Capacity Xeolas Pharmaceuticals Opens 158,000 Sq Ft State-of-the-Art Baldoyle Facility to Scale Specialty Medicine Manufacturing Priya Life Science Partners with Fleming for the 9th Annual Corporate Compliance & Transparency in Life Sciences Summit in Zurich Ireland Has the Capital and the Lessons: Digital Project Management Is How They Become Delivery Dunbar Pharma Brings First Plant-Derived Dronabinol API to UK Market Through IPS Pharma Leveraging Priya Life Science as a Data Tracker: The Ultimate Use Case & Career Guide The €100K Reality Check: Why a Six-Figure Pharma Salary in Ireland Feels Different Than in Switzerland or Germany Ireland's €93.8 Billion Non-EU Pharma Export Engine: Trade Data, Destination Markets, and Economic Impact Astellas Expands Its 330 Million Euro Tralee Biopharma Facility with a Second Aseptic Filling Line to Double Drug-Product Capacity Xeolas Pharmaceuticals Opens 158,000 Sq Ft State-of-the-Art Baldoyle Facility to Scale Specialty Medicine Manufacturing Priya Life Science Partners with Fleming for the 9th Annual Corporate Compliance & Transparency in Life Sciences Summit in Zurich Ireland Has the Capital and the Lessons: Digital Project Management Is How They Become Delivery Dunbar Pharma Brings First Plant-Derived Dronabinol API to UK Market Through IPS Pharma Leveraging Priya Life Science as a Data Tracker: The Ultimate Use Case & Career Guide The €100K Reality Check: Why a Six-Figure Pharma Salary in Ireland Feels Different Than in Switzerland or Germany Ireland's €93.8 Billion Non-EU Pharma Export Engine: Trade Data, Destination Markets, and Economic Impact
Recruiting Not applicable

Balloon vs. Self Expanding Transcatheter Valve for Degenerated Bioprosthesis

NCT04843072 · tracked via the Priya Life Science France tracker
Phase
Not applicable
Started
2021-05-01
Last updated
2026-10-13

Condition(s) studied

Valve Heart Disease

Investigational drug(s) / intervention(s)

EVOLUT R/PRO/PRO+/FX bioprosthesisEdwards Sapien S3/Ultra bioprosthesisMYVAL/Octacor/Octapro bioprosthesis

EVOLUT R/PRO/PRO+/FX bioprosthesis: To compare EVOLUT R/PRO/PRO+/FX bioprosthesis versus Edwards SAPIEN 3/Ultra bioprosthesis or Myval/Octacor/ Octapro in failing surgical bioprostheses

Edwards Sapien S3/Ultra bioprosthesis: Edwards Sapien S3/Ultra bioprosthesis

MYVAL/Octacor/Octapro bioprosthesis: MYVAL/Octacor/Octapro bioprosthesis

Study summary

Transcatheter aortic valve implantation (TAVI) serves a growing spectrum of patients with symptomatic severe aortic stenosis (AS). Approximately 80% of surgical aortic valve replacements are performed using a bioprosthesis. Durability of surgical bioprostheses varies according to patient age at the time of implantation, prosthesis type and size, among other factors. TAVI has become an established treatment option for patients with a degenerated surgical aortic bioprosthesis. The time from index surgical aortic valve replacement (SAVR) to bioprosthetic valve degeneration is typically 8-10 years. TAVI in this setting has shown favorable outcomes. Balloon-expandable and self-expanding transcatheter heart valves (THVs) can both be used for the treatment of a degenerated surgical aortic bioprosthesis and have specific advantages and limitations. Valve-in-valve TAVI may be associated with coronary obstruction, THV migration, paravalvular regurgitation, and prosthesis-patient mismatch.

Objective:

To compare valve-in-valve TAVI with balloon-expandable SAPIEN/MYVAL THV series versus the self-expanding EVOLUT THV series. The primary analysis evaluates device success at 30 days in the primary cohort. Continued enrollment will additionally support a secondary comparison of the safety and efficacy of the SAPIEN and MYVAL THV series.

Study design: International multicenter randomized study with 1:1 randomization to TAVI with the EVOLUT THV series or the SAPIEN/MYVAL THV series.

Study population:

The primary cohort comprises 440 patients with a failing surgical aortic bioprosthesis (aortic stenosis with or without aortic regurgitation) selected for transfemoral TAVI by heart-team consensus. Enrollment of the primary cohort has been completed.

The continued-enrollment cohort comprises 160 additional patients and will increase the total study population to 600 patients, with a target distribution of 300 patients treated with the EVOLUT THV series, 150 with the SAPIEN THV series, and 150 with the MYVAL THV series.

Investigational intervention:

Transfemoral valve-in-valve TAVI with a balloon-expandable SAPIEN or MYVAL THV series or a self-expanding EVOLUT THV series.

Main study parameters/endpoints:

1. Primary endpoint is device success at 30 days

Defined by:
* Absence of procedural mortality; AND
* Technical success at exit from the procedure room defined as freedom from mortality, successful access, delivery of the device and retrieval of the delivery system, correct positioning of a single prosthetic heart valve into the proper anatomical location, and freedom from surgery or intervention related to the device or to a major vascular or access-related, or cardiac structural complication; AND
* Intended performance of the prosthetic heart valve (no severe prosthesis-patient mismatch and mean aortic valve gradient \<20 mmHg or peak velocity \<3 m/s, Doppler velocity index ≥0.25, and no moderate or severe prosthetic valve regurgitation).

Severe prosthesis-patient mismatch is defined as an indexed effective orifice area (EOAi) ≤0.65 cm²/m² (≤0.55 cm²/m² if BMI ≥30 kg/m²).
2. Safety endpoint at 1 year defined by the composite of all-cause death, disabling stroke, rehospitalization for heart failure, or valve-related problems.
3. Secondary objective is comparison of the safety and efficacy of the SAPIEN versus MYVAL THV series, including the incidence of moderate or severe prosthesis-patient mismatch.

The continued-enrollment cohort is designed to support this comparison.

Eligibility

Sex
ALL
Min age
18 Years
Max age
—
Healthy volunteers
No
Inclusion Criteria: * Age ≥ 18 years * Failing surgical aortic bioprosthesis requiring valve replacement and eligible for transfemoral TAVI with balloon expandable or self-expanding platform per heart team consensus based on multi-modality imaging assessment (including echocardiography and multidetector CT). * Written informed consent Exclusion Criteria: * Not eligible for Transfemoral TAVI with EVOLUT, SAPIEN or MYVAL THV series * Multi-valve defects requiring intervention * Clinically unstable and/or inotropic/vasopressor /mechanical support. * Known mural thrombus in the left ventricle * Presence of a mechanical aortic valve * History of recent (within 1 month) stroke or TIA

Primary outcome measure(s)

  • Device success — 30 days post transcatheter valve implantation
    Defined by: * Absence of procedural mortality; AND * Technical success at exit from the procedure room defined as freedom from mortality, successful access, delivery of the device and retrieval of the delivery system, correct positioning of a single prosthetic heart valve into the proper anatomical location, and freedom from surgery or intervention related to the device or to a major vascular or access-related, or cardiac structural complication; AND * Intended performance of the prosthetic heart valve (no severe prosthesis-patient mismatch and mean aortic valve gradient \<20 mmHg or peak velocity \<3 m/s, Doppler velocity index ≥0.25, and no moderate or severe prosthetic valve regurgitation). Severe prosthesis-patient mismatch is defined as an indexed effective orifice area (EOAi) ≤0.65 cm²/m² (≤0.55 cm²/m² if BMI ≥30 kg/m²).

Trial sites (14)

FacilityCityRegionStatus
Cedars Sinai Los Angeles California Recruiting
Vienna General Hospital Vienna Austria Recruiting
St Paul's and Vancouver General Hospital Vancouver Canada Not Yet Recruiting
Rigshospitalet Copenhagen Denmark Not Yet Recruiting
Institut Cœur Poumon Lille France Recruiting
Division of Cardiology, Pulmonology, and Vascular Medicine, Heinrich Heine University Medical Center Dusseldorf, Dusseldorf, Germany Düsseldorf Germany Recruiting
University Hospital Mainz Mainz Germany Not Yet Recruiting
Department of Cardiology, Onassis Cardiac Surgery Center, Athens, Greece Athens Greece Recruiting
Interventional Cardiology Unit, Cardiovascular Department, Fondazione Poliambulanza Institute, Brescia, Italy Brescia Italy Recruiting
University Hospital of Padova Padua Italy Not Yet Recruiting
Erasmus Medical Centre Rotterdam Netherlands Recruiting
Centro Hospitalar de Lisboa Ocidental Lisbon Portugal Recruiting
Inselspital, University Hospital Bern Switzerland Not Yet Recruiting
Leeds Teaching Hospitals Leeds United Kingdom Not Yet Recruiting

Other trials for the same condition

Official registry record

This page summarises publicly available registry data for informational purposes — not medical advice. Eligibility is determined by each study team; patients should discuss participation with their clinician.

View NCT04843072 on ClinicalTrials.gov ↗ ← All trials in France