Role of Echocardiography and Ultrasound Indices in Resuscitation of Septic Shock Patients
Condition(s) studied
Investigational drug(s) / intervention(s)
carotid artery duplex: , Carotid Doppler (T0) will be performed within 1-2 Hours of ICU Admission to measure the following parameters: "Peak systolic velocity" and Velocity Time Integral over the common carotid artery. Using the linear probe (VF12-4) of ultrasound machine (ACUSON NX3, Siemens Medical solution USA, Inc.) * According to surviving sepsis campaign guidelines 2021, patients diagnosed with septic shock should be given 30ml/kg IV crystalloid fluid within the first 3 hours, the fluid will be given in the form of 500 ml boluses, each bolus should be given in 15 minutes. * FC "fluid challenge" will be performed by rapid volume infusion over (30minutes) of 1000mL Ringer acetate solution. * Carotid artery Duplex parameters will be repeated. Relative changes in "Peak Systolic Velocity, Velocity Time integral" will be expressed in
Left ventricular end diastolic area: * Echocardiography (T0) will be performed within 1-2 Hours of ICU Admission to measure LVEDA if less than 10 cm2 then the patient will be considered hypovolemic. * According to surviving sepsis campaign guidelines 2021, patients diagnosed with septic shock should be given 30ml/kg IV crystalloid fluid within the first 3 hours, the fluid will be given in the form of 500 ml boluses, each bolus should be given in 15 minutes. * FC "fluid challenge" will be performed by rapid volume infusion over (30minutes) of 1000mL Ringer acetate solution. * After five minutes from FC "fluid challenge" (T1), echocardiography will be repeated to re-measure LVEDA. Pt will be defined as a responder if LVEDA b
Study summary
Fluid replacement is considered the cornerstone of hemodynamic management in critically ill patients especially in patients with septic shock. However, only about 50% of critically ill hemodynamically unstable patients are responsive to fluids. Consequently, the resuscitation of critically ill patients requires an accurate assessment of the patients' intravascular volume status and their volume responsiveness. In this study, we will compare the efficacy of carotid artery flow to echo left ventricular end diastolic volume as a predictive value for fluid resuscitation in septic shock patients.
Eligibility
Primary outcome measure(s)
- Accuracy of echo and ultrasound indices — 1 Day
Diagnostic accuracy (sensitivity, specificity) of LVEDA and carotid artery flow parameters (PEAK Systolic Velocity, Velocity time integral (VTI), in predicting fluid responsiveness defined as an increase in stroke volume after a standardized fluid challenge.
Trial sites (1)
| Facility | City | Region | Status |
|---|---|---|---|
| Faculty of medicine, Ain Shams University | Cairo | Egypt | Recruiting |
More Ain Shams University trials in Egypt
Other trials for the same condition
This page summarises publicly available registry data for informational purposes — not medical advice. Eligibility is determined by each study team; patients should discuss participation with their clinician.
View NCT07550400 on ClinicalTrials.gov ↗ ← All trials in Egypt