Impact of Aortic Geometry on Vascular Remodeling After Stent Implantation in Coarctation of the Aorta
Condition(s) studied
Investigational drug(s) / intervention(s)
CT aortography: Performed before and after stenting using a multidetector CT scanner (device model and parameters to be specified). Analysis will include: * Evaluation of aortic arch geometry (normal / gothic / crenel). * Measurement of residual stenosis at the site of coarctation. * Aortic diameter measurements at predefined anatomical levels: Ascending aorta (AA), Proximal descending thoracic aorta (PDA), At the level of the diaphragm (DA), Abdominal aorta (AbAo). \- Aortic tortuosity. All CT data will be interpreted by two independent observers blinded to clinical outcomes
CMR: CMR examinations will be performed using a commercially available 1.5 Tesla whole-body scanner (Ingenia, Philips Healthcare, release 4.1.3.0). In pediatric or uncooperative patients, free-breathing sequences were used when breath-holding was not feasible. Brachial blood pressure was measured in the right arm in the supine position immediately before image acquisition using automated oscillometric devices. Cine steady-state free precession (SSFP) sequences were obtained in multiple views including the short axis of the ascending aorta (AAO) and descending aorta (DAO), as well as the aortic root to evaluate aortic valve morphology (bicuspid vs tricuspid). Left ventricular (LV) and left atrial (LA) functional parameters were assessed by standard volumetric analysis. The following CMR-derived parameters were collected: Left ventricular ejection fraction (LVEF) Left ventricular strain Left ventricular mass index (LVMI) Left atrial volume Left atrial strain LV and LA strain were analyzed usi
Study summary
This study aims to assess:
1. Aortic geometrical changes and their relationship to hypertension and cardiovascular events.
2. Aortic geometrical differences between healthy individuals and patients with repaired coarctation of the aorta.
Eligibility
Primary outcome measure(s)
- Change in Systolic Blood Pressure — Baseline and 6 months post-stenting
Difference in systolic blood pressure between baseline (pre-stenting) and 6 months post-stenting using standardized clinical sphygmomanometer. Unit of Measure: mmHg - Change in Diastolic Blood Pressure — Baseline and 6 months post-stenting
Difference in diastolic blood pressure between baseline (pre-stenting) and 6 months post-stenting using standardized clinical sphygmomanometer. Unit of Measure: mmHg
Trial sites (1)
| Facility | City | Region | Status |
|---|---|---|---|
| Institutional Review Board (IRB) of Faculty of Medicine | Asyut | Egypt |
More Assiut University trials in Egypt
This page summarises publicly available registry data for informational purposes — not medical advice. Eligibility is determined by each study team; patients should discuss participation with their clinician.