Ireland
--:--IST
Latest
Astellas Expands Its 330 Million Euro Tralee Biopharma Facility with a Second Aseptic Filling Line to Double Drug-Product Capacity Xeolas Pharmaceuticals Opens 158,000 Sq Ft State-of-the-Art Baldoyle Facility to Scale Specialty Medicine Manufacturing Priya Life Science Partners with Fleming for the 9th Annual Corporate Compliance & Transparency in Life Sciences Summit in Zurich Ireland Has the Capital and the Lessons: Digital Project Management Is How They Become Delivery Dunbar Pharma Brings First Plant-Derived Dronabinol API to UK Market Through IPS Pharma Leveraging Priya Life Science as a Data Tracker: The Ultimate Use Case & Career Guide The €100K Reality Check: Why a Six-Figure Pharma Salary in Ireland Feels Different Than in Switzerland or Germany Ireland's €93.8 Billion Non-EU Pharma Export Engine: Trade Data, Destination Markets, and Economic Impact Astellas Expands Its 330 Million Euro Tralee Biopharma Facility with a Second Aseptic Filling Line to Double Drug-Product Capacity Xeolas Pharmaceuticals Opens 158,000 Sq Ft State-of-the-Art Baldoyle Facility to Scale Specialty Medicine Manufacturing Priya Life Science Partners with Fleming for the 9th Annual Corporate Compliance & Transparency in Life Sciences Summit in Zurich Ireland Has the Capital and the Lessons: Digital Project Management Is How They Become Delivery Dunbar Pharma Brings First Plant-Derived Dronabinol API to UK Market Through IPS Pharma Leveraging Priya Life Science as a Data Tracker: The Ultimate Use Case & Career Guide The €100K Reality Check: Why a Six-Figure Pharma Salary in Ireland Feels Different Than in Switzerland or Germany Ireland's €93.8 Billion Non-EU Pharma Export Engine: Trade Data, Destination Markets, and Economic Impact
Active, not recruiting Observational

Concealed Myocardial Abnormalities by Cardiac Magnetic Resonance Imaging in Idiopathic VT

NCT06146556 · tracked via the Priya Life Science Egypt tracker
Phase
Observational
Started
2024-01-01
Last updated
2025-01-31

Condition(s) studied

Premature Ventricular Contractions

Investigational drug(s) / intervention(s)

catheter based ablation

catheter based ablation: electrophysiological catheter based ablation of ventricular arrhythmia

Study summary

Idiopathic Ventricular arrhythmia (VAs) refers to VAs that occur in the absence of clinically apparent structural heart disease. The outflow tracts (OTs) are the most common origin of idiopathic VAs and PVCs, accounting for approximately 10% of all patients referred for evaluation of VAs with the RVOT being the origin of about 70-80% of these arrhythmias.

Studies have shown that increased PVC burden was associated with reduced LV function, a higher incidence of heart failure, and a higher risk of death.

The diagnosis, prognostication and treatment of patients with VAs are challenging. A routine diagnostic workup that includes transthoracic echocardiography and an assessment for the presence of coronary artery disease (CAD) as recommended by current clinical guidelines cannot recognize focal structural abnormalities or underlying structural heart disease (SHD) in a substantial proportion of patients. Cardiac magnetic resonance (CMR) provides an excellent assessment of cardiac morphology and function and enables a detailed myocardial tissue characterization with a high degree of precision. CMR is widely regarded as the gold standard for identifying structural arrhythmogenic substrates in patients with VAs and normal echocardiography.

Eligibility

Sex
ALL
Min age
—
Max age
—
Healthy volunteers
Accepted
Inclusion Criteria: * All patients presented with idiopathic ventricular arrhythmias with normal diagnostic routine workup at Assiut university heart hospital. Diagnostic work up including a normal ECG with no changes suggestive of structural heart disease, normal echocardiography findings and no evidence of CAD on either invasive or non-invasive imaging Exclusion Criteria: * (1) known history of cardiac disease (CAD, cardiomyopathy, congenital heart disease, more than mild valvular disease, previous cardiac surgery of any type), any severe systemic disease with cardiac involvement. (2) Allergy to gadolinium-based contrast agents, an estimated glomerular filtration rate \< 30 mL/min/1.73 m2. (3) Any contraindication to the MR environment (e.g., MR-unsafe implants/devices, shrapnel injury), pregnancy and claustrophobia

Primary outcome measure(s)

  • Assess the diagnostic yield of cardiac MRI in early detection of biventricular dysfunction in patients with idiopathic VAs — one year
    the value of CMR in evaluation of ventricular dysfunction in patients with ventricular arrhythmias

Trial sites (1)

FacilityCityRegionStatus
Assiut university Asyut Egypt
Official registry record

This page summarises publicly available registry data for informational purposes — not medical advice. Eligibility is determined by each study team; patients should discuss participation with their clinician.

View NCT06146556 on ClinicalTrials.gov ↗ ← All trials in Egypt