Data Acquisition: Develop algorithms for determining the cardiac output through the synchronous acquisition of hemodynamic data from the pulmonary artery catheter or other pressure sensors and Impella using a network module.
Study summary
Abiomed IMPELLA-RT-DAQ - Impella Real Time Data AcQuisition
Eligibility
Sex
ALL
Min age
18 Years
Max age
—
Healthy volunteers
No
Inclusion Criteria:
1. Ongoing or planned intensive care management with Impella support
2. Presence or planned placement of a cardiac output measurement
1. Preferentially pulmonary catheter (including cardiac output (CO) preferred as continuous measurement)
2. Other means of discontinuous CO measurement incl. echocardiography, other thermodilution methods
Exclusion Criteria:
1. Age \< 18 years
2. Pregnancy
3. Anticipated support duration \<24 h
Primary outcome measure(s)
Collection of hemodynamic parameters (Cardiac Output in l/min) — From Impella insertion unitl Impella support is permanently weaned, on average 2 days Synchronous data acquisition of the Impella system parameters (pressure measurement, motor current, operating data) and the monitoring system (Philipps IntelliVue) using a network module (HighDim) that is connected by either a wired or wireless access.
Collection of hemodynamic parameters (Blood Pressure in mmHg, Pulmonary Artery Pressure in mmHg, Central Venous Pressure in mmHg, Pulmonary Capillary Wedge Pressure in mmHg) — From Impella insertion unitl Impella support is permanently weaned, on average 2 days Synchronous data acquisition of the Impella system parameters (pressure measurement, motor current, operating data) and the monitoring system (Philipps IntelliVue) using a network module (HighDim) that is connected by either a wired or wireless access.
Collection of hemodynamic parameters (Mixed Venous Saturation in %) — From Impella insertion unitl Impella support is permanently weaned, on average 2 days Synchronous data acquisition of the Impella system parameters (pressure measurement, motor current, operating data) and the monitoring system (Philipps IntelliVue) using a network module (HighDim) that is connected by either a wired or wireless access.
Collection of hemodynamic parameters (Pulmonary Vascular Resistance in In dynes/sec/cm-5 ) — From Impella insertion unitl Impella support is permanently weaned, on average 2 days Synchronous data acquisition of the Impella system parameters (pressure measurement, motor current, operating data) and the monitoring system (Philipps IntelliVue) using a network module (HighDim) that is connected by either a wired or wireless access.