Elevate™ System: The Elevate™ percutaneous Left Ventricular Assist Device System
Study summary
The Elevate™ CS Clinical Feasibility Study is designed to evaluate the initial safety, effectiveness, and device performance of the Magenta Elevate™ System in patients with cardiogenic shock due to isolated or predominant left ventricular failure.
Eligibility
Sex
ALL
Min age
40 Years
Max age
89 Years
Healthy volunteers
No
Inclusion Criteria:
* Cardiogenic shock of less than 24 hours duration.
* Left ventricular ejection fraction \< 45% and \> 15%, as determined by echocardiography on the day of inclusion.
* No more than mild right ventricular dysfunction, as determined by echocardiography on the day of inclusion.
* Signed informed consent.
Exclusion Criteria:
* Other causes of shock: hypovolemia, sepsis (any active systemic infection including acute myocarditis), pulmonary embolism or anaphylaxis.
* Patient with oxygen saturation \< 90% (pulse oximeter/arterial) at the planned time of device placement (uncorrected by oxygen supplementation or intubation).
* Sustained VT (at the time of the enrollment).
* Significant right heart failure/right ventricular dysfunction.
* Awake patient who is unable to remain in a stable recumbent position due to restlessness or lack of cooperation for other reasons.
* Hypertrophic obstructive cardiomyopathy.
* Left ventricular thrombus.
* Subjects with a placed IABP.
* Mitral and/or aortic valve prothesis, or more than mild native mitral or aortic valve stenosis.
* Aortic valve insufficiency ≥ 2+ (on a 4-grade scale).
* Mechanical complication of myocardial infarction (e.g., ventricular septal rupture, papillary muscle rupture) or evidence of uncorrected Ventricular Septal Defect or Atrial Septal Defect (VSD/ASD).
* Brain damage (e.g., anoxic) or suspected brain damage.
* Stroke or transient ischemic attack within the past 3 months.
* Uncorrectable abnormal coagulation parameters (defined as platelet count \< 100,000 or INR \> 2.0 or fibrinogen \< 1.5 g/L) or active uncontrolled bleeding.
* Allergy, sensitivity or intolerance to heparin, aspirin, Adenosine Diphosphate (ADP) receptor blockers, or contrast media, including known heparin-induced thrombocytopenia.
* Known allergy, sensitivity or intolerance to nickel.
* Known or suspected severe lung disease.
* Evidence of any vascular disease that would preclude placement of the device (e.g., severely calcified and stenosed ilio-femoral vessels).
* Aortic pathology, such as aortic aneurysms, extreme tortuosity, or calcifications that could pose an undue additional risk to the placement of a pLVAD device.
* Any known or suspected disorder causing fragility of blood cells or hemolysis.
* Subject participation in another investigational drug or device trial (post-market registries may be approved by Magenta Medical).
* Life expectancy \< 1 year due to comorbidities.
Primary outcome measure(s)
Initial Safety — From device delivery through device removal The rate of the composite of Major Device-Related Adverse Events
Device Effectiveness — From baseline to 30 minutes of device activation Hemodynamic stability and/or improvement from baseline following device activation, defined as:
* Number (percentage) of patients with MAP\>60mmHg
* Improvement in MAP
Device Performance — From device delivery through device removal * Rate of successful delivery of the Elevate™ System
* Rate of successful deployment of the Elevate™ System
* Rate of successful use of the Elevate™ System
* Rate of successful retrieval of the Elevate™ System
Trial sites (8)
Facility
City
Region
Status
Israeli-Georgian Medical Research Clinic Helsicore
This page summarises publicly available registry data for informational purposes — not medical advice. Eligibility is determined by each study team; patients should discuss participation with their clinician.
We use cookies to analyse site traffic and improve your experience. With your consent, we may also use cookies for advertising. You can change your choice at any time.