Ireland
--:--IST
Latest
Clinical Trials in France / NCT07074431
Recruiting Not applicable

"Comparative Study of High-frequency Pulsed Vacuum Technology Versus Phacoemulsification for Cataract Surgery

NCT07074431 · tracked via the Priya Life Science France tracker
Sponsor
Clinique Victor Pauchet
Phase
Not applicable
Started
2025-12-12
Last updated
2026-03-31

Condition(s) studied

Cataract Bilateral

Investigational drug(s) / intervention(s)

EYE 1 SURGERY BY CATAPULSE TECHNICEYE 2 SURGERY BY CATAPULSE TECHNIC

EYE 1 SURGERY BY CATAPULSE TECHNIC: In arm 2: 1st eye operated by high-frequency pulsed vacuum technology / 2nd eye operated by phacoemulsification

EYE 2 SURGERY BY CATAPULSE TECHNIC: In arm 1: 1st eye operated by phacoemulsification / 2nd eye operated by high-frequency pulsed vacuum technology

Study summary

Cataracts are cloudings of the lens, primarily due to aging. Surgery is the primary treatment for cataracts. The most commonly used surgical technique is phacoemulsification, which involves fragmenting the lens using a high-frequency ultrasound probe and removing the fragments. Phacoemulsification is more common due to its advantages.

Recently, a new approach has emerged, using high-frequency pulsed vacuum technology for cataract ablation. This less invasive approach is expected to allow for faster patient recovery and reduce surgical risks. High-frequency pulsed vacuum utilizes the pulse-pulse principle by interrupting the vacuum every tenth of a second. This interruption creates an impact moment between the cataract material and the cannula tip, dissecting the cataract without damaging the surrounding delicate tissue. High-frequency pulsed vacuum maintains anterior chamber stability while creating sufficient dissection to aspirate the cataract material. This energy also cools the tip, allows for better vacuum control, and significantly reduces turbulence within the eye. More importantly, high-frequency pulsed vacuum disrupts endothelial cells less and causes less edema than mechanical ultrasound.

This technique therefore appears ideal for treating patients with at-risk corneas (low endothelial cell count, risk of decompensation and corneal transplantation).

The objective of the study is to demonstrate the benefits of this approach using high-frequency pulsed vacuum technology through a randomized, comparative, crossover study.

Eligibility

Sex
ALL
Min age
18 Years
Max age
—
Healthy volunteers
No
Inclusion Criteria: * Adult patient * Patient with bilateral cataracts * Grade 1 to 3 cataracts * Indication for bilateral cataract surgery * Patient informed of the study and having given their written and signed informed consent * Patient affiliated with a social security scheme or beneficiary of such a scheme Exclusion Criteria: * Refusal of consent * Cataract grade \> 3 * Unilateral and/or combined cataract surgery * Uveitic cataract * Glaucoma * Patient with ocular comorbidity * Patient with cognitive impairment preventing them from responding to satisfaction questionnaires * Patient unable to read, write, or understand French * Pregnant or breastfeeding patient as defined in Article L1121-5 of the French Public Health Code * Vulnerable patient as defined in Article L1121-6 of the French Public Health Code * Adult patient under guardianship, curatorship, or legal protection * Patient unable to give personal consent

Primary outcome measure(s)

Trial sites (1)

FacilityCityRegionStatus
Clinique Victor Pauchet Amiens France Recruiting

Other trials for the same condition

Official registry record

This page summarises publicly available registry data for informational purposes — not medical advice. Eligibility is determined by each study team; patients should discuss participation with their clinician.

View NCT07074431 on ClinicalTrials.gov ↗ ← All trials in France