One-lung ventilation is frequently required in thoracic surgery and is most commonly achieved using double-lumen endobronchial tubes (DLTs). Correct positioning of the DLT is crucial for effective lung isolation and patient safety. Fiberoptic bronchoscopy (FOB) is considered the gold standard for confirming DLT placement; however, it may not always be immediately available and requires specific expertise.
Lung ultrasonography is a rapid, noninvasive, and bedside imaging method increasingly used in anesthesiology and critical care. This prospective observational study aims to evaluate the diagnostic performance of lung ultrasound in confirming the correct position of double-lumen endobronchial tubes in patients undergoing thoracic surgery.
The results obtained from lung ultrasound will be compared with auscultation findings and fiberoptic bronchoscopy results. Fiberoptic bronchoscopy will be considered the reference standard. The sensitivity, specificity, positive predictive value, and negative predictive value of lung ultrasound and auscultation will be calculated.
| Facility | City | Region | Status |
|---|---|---|---|
| Izmir City Hospital | Izmir | İzmir | Recruiting |
This page summarises publicly available registry data for informational purposes — not medical advice. Eligibility is determined by each study team; patients should discuss participation with their clinician.
View NCT07465510 on ClinicalTrials.gov ↗ ← All trials in Turkey