🇮🇪Ireland
16°C Partly Cloudy · Dublin
Live Updates
--:--:-- IST
Contributor sign in
Latest
Clinical Trials in Germany / NCT03982940
Active, not recruiting Not applicable

BGP+ Stent as Bridging Stent in BEVAR

NCT03982940 · tracked via the Priya Life Science Germany tracker
Sponsor
Marc Bosiers, MD
Phase
Not applicable
Started
2020-09-09
Last updated
2025-04-09

Condition(s) studied

Thoracoabdominal Aortic Aneurysm, Without Mention of Rupture

Investigational drug(s) / intervention(s)

BGP+ Stent Graft System as bridging stent

BGP+ Stent Graft System as bridging stent: BGP+ Stent Graft System as bridging stent

Study summary

The objective of this clinical investigation is to evaluate, in a controlled setting, the safety and performance of the BGP+ balloon expandable covered stent Graft System (Bentley InnoMed, Hechingen, Germany) implanted as bridging stent in BEVAR (branched endovascular aortic repair) for complex aortic aneurysms.

Eligibility

Sex
ALL
Min age
55 Years
Max age
—
Healthy volunteers
No
Inclusion Criteria: 1. Patient eligible for elective repair of TAAA with BEVAR in accordance with the applicable guidelines for vascular interventions (e.g. Aneurysm size 6cm or aneurysm growth of \>5mm within 6 months or 1cm within 1 year) 2. Patient is willing to comply with specified follow-up evaluations at the specified times 3. Patient is \>55 years old 4. Patient understands the nature of the procedure and provides written informed consent, prior to enrolment in the trial • Patient has a projected life-expectancy of at least 12-months 5. Patient needs to have a landing zone in their target vessel of at least 15 mm, and coverage/ wall adaptation of the BGP+ should be obtained for at least 10 mm. 6. The access vessel for introduction of the sheath through which the BGP+ will be advanced should be at least 3mm (it should be able to fit a 8F sheath) 7. No early important division branch from the target vessel with risk of coverage 8. Absence of pre-existing dissection in the target vessels 9. Target vessels (renal arteries, superior mesenteric artery, and celiac trunk) for the BGP+ must have a diameter between 5 and 10 mm 10. Aortic endoprosthesis with inner branches (can be hybrid or branches only) 11. Hybrid aortic endoprosthesis with fenestrations and branches (at least 2 and only the target vessels which are connected by a branch shall be treated with a study device within this study) 12. At least one target vessel is bridged with only one BGP+ (relining allowed) 13. Full compliance with all inclusion criteria/exclusion criteria and all intraoperative criteria Exclusion Criteria: 1. Previously implanted stent in the target vessel 2. Renal artery with \>100° cranial orientation 3. Patients refusing treatment 4. Patients for whom antiplatelet therapy, anticoagulants or thrombolytic drugs are contraindicated 5. Patients with uncorrected bleeding disorders or heparin induced thrombocytopenia 6. Female patient with childbearing potential not taking adequate contraceptives or currently breastfeeding 7. Any planned surgical intervention/procedure within 30 days of the trial procedure 8. Patients with rupture or any patient considered to be hemodynamically unstable at onset of procedure 9. Patient is currently participating in another conflicting investigational drug or device trial that has not completed the entire follow up period. 10. Patients with diffuse distal disease resulting in poor stent outflow 11. Fresh thrombus formation within the last 14 days 12. Patients with known hypersensitivity to the stent material (L605) and/or PTFE 13. Hybrid Approach (endovascular in combination with open surgery) 14. Patients with a connective tissue disorder 15. Patients with mycotic or inflammatory aneurysm 16. Myocardial infarction or stroke within 3 months prior to the procedure 17. Patients with an unstable angina pectoris or heart insufficiency NYHA 3 or 4 18. Patients with ASA classification 5 or higher 19. Contraindications against contrast enhanced angiography (a.e. massive hyperthyroidism) 20. Patients with increased risk of intraoperative rupture 21. Patients with access vessel which are too tortuous, narrow or any kind of reason that would lead to failure of introducing and advancing an introducer sheath

Primary outcome measure(s)

Trial sites (10)

FacilityCityRegionStatus
Prof. Dr. med. Dittmar Böckler - Klinik für Gefäßchirurgie und Endovaskuläre Chirurgie Heidelberg Baden-Wurttemberg
Prof. Dr. Jost Philipp Schäfer Klinik für Radiologie und Neuroradiologie Kiel Schleswig-Holstein
Alexander Gombert Aachen Germany
University Hospital Eppendorf, UKE Hamburg Hamburg Germany
University Hospital Leipzig Leipzig Germany
University Hospital LMU Munich Munich Germany
St. Franziskus Hospital Münster Germany
Klinikum Nürnberg Süd Nuremberg Germany
Karin Pfister Regensburg Germany
Hospital Stuttgart Stuttgart Germany

More Marc Bosiers, MD trials in Germany

Other trials for the same condition

Official registry record

This page summarises publicly available registry data for informational purposes — not medical advice. Eligibility is determined by each study team; patients should discuss participation with their clinician.

View NCT03982940 on ClinicalTrials.gov ↗ ← All trials in Germany