🇮🇪Ireland
16°C Partly Cloudy · Dublin
Live Updates
--:--:-- IST
Contributor sign in
Latest
Clinical Trials in the Netherlands / NCT05788770
Unknown Not applicable

Preoperative CT-imaging with Patient-specific Computer Simulation in Transcatheter Aortic Valve Replacement

NCT05788770 · tracked via the Priya Life Science Netherlands tracker
Sponsor
Romy Hegeman
Phase
Not applicable
Started
2022-04-06
Last updated
2024-09-19

Condition(s) studied

Aortic Valve Stenosis

Investigational drug(s) / intervention(s)

FEops HEARTGuide

FEops HEARTGuide: FEops HEARTGuide added to routine preoperative CT imaging. Results of the computer modelling will be discussed with TAVR implanting team prior to and during the procedure.

Study summary

Combining routine preoperative CT imaging with patient-specific computer modelling predicts the interaction between different sizes of transcatheter aortic valve replacement devices at different implantation depths and the patient's unique anatomy (including post-implantation deformation) allowing preoperative evaluation of the risk for paravalvular leakage and conduction disorders.

The objective of this randomized controlled trial is to evaluate whether pre-operative CT-imaging with advanced computer modelling and simulation (FEops HEARTguide™) adequately predicts procedural outcomes in TAVR procedures, whether it leads to changes of preoperative decisions and whether or not this leads to improved outcome in TAVR procedures.

Eligibility

Sex
ALL
Min age
18 Years
Max age
—
Healthy volunteers
No
Inclusion Criteria: * Primary symptomatic severe aortic valve stenosis * Accepted for TAVR, either by transfemoral, transsubclavian or transapical access * Plan to implant one of the following transcatheter heart valves for which FEops HEARTguide™ is available (CoreValve™ Evolut™ R, and Evolut™ PRO and Evolut™ PRO+ (Medtronic, Minnesota, USA), ACURATE neo™ and ACURATE neo 2™ (Boston Scientific, Marlborough, MA, USA) * Informed consent Exclusion Criteria:a potential subject who meets any of the following criteria will be excluded from participation in this study before randomization: * Previous surgical aortic valve replacement * Permanent pacemaker at baseline * Emergency procedure * Poor CT image quality (disabling computer-simulation, i.e. generation of 3D anatomical models will not be possible with poor CT image quality), for example because of motion artifacts due to the presence of other implanted devices affecting the region of interest * Patient who did not agree to the informed consent and/or refused to participate * Patient unable to understand the informed consent/study

Primary outcome measure(s)

Trial sites (2)

FacilityCityRegionStatus
Vienna General Hospital Vienna Austria Recruiting
St. Antonius Hospital Nieuwegein Utrecht Recruiting

More Romy Hegeman trials in the Netherlands

Other trials for the same condition

Official registry record

This page summarises publicly available registry data for informational purposes — not medical advice. Eligibility is determined by each study team; patients should discuss participation with their clinician.

View NCT05788770 on ClinicalTrials.gov ↗ ← All trials in the Netherlands