🇮🇪Ireland
16°C Partly Cloudy · Dublin
Live Updates
--:--:-- IST
Contributor sign in
Latest
Clinical Trials in Germany / NCT05540223
Active, not recruiting Not applicable

Safety and Clinical Performance of the Freesolve Resorbable Magnesium Scaffold System

NCT05540223 · tracked via the Priya Life Science Germany tracker
Phase
Not applicable
Started
2024-05-13
Last updated
2026-07-07

Condition(s) studied

Coronary Artery DiseaseAtherosclerosis, CoronaryMyocardial IschemiaIschemic Heart DiseaseAcute Coronary SyndromeAngina Pectoris

Investigational drug(s) / intervention(s)

Freesolve RMSXience DES

Freesolve RMS: Subject undergoes implantation of Freesolve RMS

Xience DES: Subject undergoes implantation of Xience DES

Study summary

The objective of this study is to assess the safety and efficacy of the Freesolve in the treatment of subjects with up to two de novo lesions in native coronary arteries compared to a contemporary drug eluting stent (DES).

Eligibility

Sex
ALL
Min age
18 Years
Max age
80 Years
Healthy volunteers
No
Clinical Inclusion Criteria: 1. Subject is ≥ 18 years and ≤ 80 years of age 2. Subject has provided written informed consent as approved by the Independent Ethical Committee (IEC) or Institutional Review Board (IRB) of the respective clinical site prior to the study related procedures 3. Subject is eligible for PCI according to the applicable guidelines 4. Subject is an acceptable candidate for coronary artery bypass surgery 5. Subjects with stable or unstable angina pectoris, documented silent ischemia/abnormal physiologic testing or hemodynamically stable non-ST elevation myocardial infarction (NSTEMI) patients without angiographic evidence of thrombus at target lesion Note: STEMI patients may be eligible for the study for treatment of selected non-culprit lesions, if: * Subject and target lesion(s) meet all inclusion and no exclusion criteria and consent occurs at least ≥ 72 hours after successful treatment of the culprit lesion(s) \[lesion(s) causing the acute STEMI\]; * Subject is hemodynamically stable with documented declining cardiac biomarkers; * Target lesion(s) to be treated are not located in the culprit vessel(s) and are not culprit lesion(s) 6. Subject is eligible for Dual Antiplatelet Therapy (DAPT) with aspirin plus either clopidogrel, prasugrel, ticagrelor or ticlopidine 7. Documented left ventricular ejection fraction (LVEF) ≥ 30% within 6 months prior to or during the procedure (prior to randomization) 8. Subject is willing and able to comply with protocol requirements, including completion of study visits for the duration of the study Angiographic Inclusion Criteria: 1. Subjects with a maximum of two single de novo target lesions each in separate native coronary arteries 2. Target vessel must have a reference diameter between 2.5-4.2 mm by visual estimation, which may be assisted by Quantitative Coronary Angiography (QCA) / Intravascular Ultrasound (IVUS) / Optical Coherence Tomography (OCT) 3. Target lesion must be ≤28mm in length by operator visual estimation, which may be assissted by QCA / IVUS / OCT, (or \< 20 mm for target lesion(s) to be treated with a study device \< 3.0 mm in diameter) and should be amenable to treatment with a single study device 4. Target lesion stenosis ≥ 50% and \< 100% by operator visual estimation, which may be assisted by QCA / IVUS / OCT. Target lesion stenosis \< 70% by visual estimation, should have clinical justification for treatment as per local standards. 5. Target lesion must have a Thrombolysis In Myocardial Infarction (TIMI) flow ≥1 Clinical Exclusion Criteria: 1. Subject is pregnant and/or breastfeeding or intends to become pregnant during the duration of the study 2. Subject has clinical symptoms and/or electrocardiogram (ECG) changes consistent with STEMI \< 72 hours prior to the index procedure. Note: Hemodynamically stable non-STEMI (NSTEMI) subjects are eligible for study enrollment. 3. Subject has undergone prior PCI within the target vessel during the last 12 months prior to the index procedure or prior PCI within a non-target vessel \<72 hours prior to the index procedure if successful and uncomplicated 4. Subject is on dialysis or with impaired renal function (serum creatinine \> 2.5 mg/dL or 221 µmol/L, determined within 72 hours prior to the index procedure) 5. Subject has a known allergy to contrast medium that cannot be adequately premedicated, or any known allergy to aspirin, P2Y12 inhibitors, both heparin and bivalirudin, sirolimus, everolimus (or similar limus drugs), poly L-lactide, the scaffold material (magnesium, aluminium, tantalum), or Xience stent material (cobalt, chromium, tungsten, nickel, -methacrylic polymer, and fluoropolymer) 6. Subject is receiving oral or intravenous immunosuppressive therapy (inhaled steroids are permitted) or has known life-limiting immunosuppressive or autoimmune disease (e.g., human immunodeficiency virus, systemic lupus erythematosus; diabetes mellitus is permitted) 7. Life expectancy less than 1 year 8. Planned surgery or dental surgical procedure within 6 months after index procedure, unless DAPT can be maintained 9. In the investigator's opinion subject will not be able to comply with the follow-up requirements 10. Subjects under oral anticoagulation therapy (OAC) prior to index procedure unless DAPT + OAC (i.e. triple therapy) can be maintained for a minimum of 1 month 11. Subject has had a stroke or transient ischemic attack (TIA) within 6 months prior to the index procedure 12. Subject with active bleeding disorder, active coagulopathy, or any other reason, who is ineligible for DAPT 13. Subject is currently participating or plans to participate in another study with an investigational device or an investigational drug Angiographic Exclusion Criteria: 1. Target vessel has been previously treated and the target lesion is within 5 mm proximal or distal to the previously treated lesion 2. Left main coronary artery disease 3. Target lesion was totally occluded (100% stenosis) 4. Thrombus in target vessel 5. Future planned staged PCI either in target or non-target vessel 6. Ostial target lesion within the left descending (LAD), left circumflex (LCx), or right coronary artery (within 5.0 mm of vessel origin) 7. Target lesion involves a side branch ≥ 2.0 mm in diameter that requires a two-device strategy after pre-dilatation 8. Target lesion is located in or supplied by an arterial or venous bypass graft 9. Target lesion with excessive tortuosity proximal to or within the lesion based on visual estimation or heavily calcified target lesion which cannot be adequately pre-dilated by a non-compliant and/or cutting/scoring balloon as described in angiographic exclusion criteria 10. 10. The target lesion requires treatment with the device other than the non-compliant balloon and/or cutting/scoring balloon prior to scaffold/stent placement (including but not limited to atherectomy devices, intravascular lithotripsy, drug-coated balloons etc.) 11. Target vessel was treated with brachytherapy any time prior to the index procedure. 12. Unsuccessful pre-dilatation, defined as residual stenosis \> 20% (by visual estimation) and / or angiographic complications (e.g. distal embolization, side branch closure, flow-limiting dissections)

Primary outcome measure(s)

Trial sites (1)

FacilityCityRegionStatus
Rheinland Klinikum Neuss GmbH Lukaskrankenhaus Neuss Neuss Germany

More Biotronik AG trials in Germany

Other trials for the same condition

Official registry record

This page summarises publicly available registry data for informational purposes — not medical advice. Eligibility is determined by each study team; patients should discuss participation with their clinician.

View NCT05540223 on ClinicalTrials.gov ↗ ← All trials in Germany