VitaFlow+GDMT: The patient will undergo transcatheter aortic valve replacement on the basis of guideline-directed medical therapy with The VitaFlow™ system. The VitaFlow™ system (MicroPort®, Shanghai, China) was a novel TAVR system, which incorporates high-radial force and a double layer polyethylene terephthalate (PET) skirt to optimize frame geometry and minimize the risks of paravalvular leak (PVL). The VitaFlow™ transcatheter aortic valve is made of a self-expanding nitinol frame and tri-leaflet bovine pericardial valve.
J-Valve+GDMT: The patient will undergo transfemoral aortic valve replacement on the basis of guideline-directed medical therapy with The J-Valve system (Jie ChengMedical Technologies, Suzhou, China). The J-Valve system is a second-generation self-expand able device composed of a porcine bioprosthetic aortic valve and a transfemoral delivery sheath. The valve is supported by a self-expanding nitinol structure. The different valve sizes are 21, 23, 25, 27, 29 and 34 mm. Three U-shaped nitinol graspers were designed to surround the valve.
This study is a prospective, multicenter, non-randomized controlled trial, planning to enroll 180 patients with pure native aortic regurgitation. On the basis of standardized medical therapy, patients will be assigned in a 1:1 ratio to undergo transfemoral transcatheter aortic valve replacement (TF-TAVR) . This prospective, multicenter trial aims to evaluate the safety and effectiveness of transfemoral TAVR using the VitaFlow™ self-expanding valve system compared to dedicated transcatheter devices in patients with PNAR.
The primary endpoint is a composite of all-cause mortality, disabling stroke, and rehospitalization for heart failure, myocardial Infarction, and requiring dialysis or valve reoperation at 12 months post-procedure.
Secondary endpoints include procedure-related complications, long-term clinical events, patient functional status and quality of life, bioprosthetic valve imaging follow-up, echocardiographic parameters, and treatment costs. All endpoint definitions conform to the Valve Academic Research Consortium-3 (VARC-3) criteria
| Facility | City | Region | Status |
|---|---|---|---|
| Ruijin hospital, Shanghai JiaoTong University School of Medicine | Shanghai | Shanghai Municipality | Recruiting |
| Shanghai Chest Hospital | Shanghai | Shanghai Municipality | Recruiting |
| Zhongshan Hospital, Fudan University | Shanghai | Shanghai Municipality | Recruiting |
| Changhai Hospital | Shanghai | Shanghai Municipality | Recruiting |
This page summarises publicly available registry data for informational purposes — not medical advice. Eligibility is determined by each study team; patients should discuss participation with their clinician.
View NCT06818084 on ClinicalTrials.gov ↗ ← All trials in China