Single vision spectacle lens: Standard single vision spectacle lens
Single vision spectacle lens + S.T.O.P.® Kit 1: Standard single vision spectacle lens + S.T.O.P.® Kit 1
Single vision spectacle lens + S.T.O.P.® Kit 2: Standard single vision spectacle lens + S.T.O.P.® Kit 2
Single vision spectacle lens + S.T.O.P.® Film: Standard single vision spectacle lens + S.T.O.P.® Film
Standard single vision spectacle lens + S.T.O.P.® Kit 1 or 2: Standard single vision spectacle lens + S.T.O.P.® Kit 1 or 2
Study summary
There are two parts to this trial. First, to compare the rate of myopia progression of spectacle films using Spatio Temporal Optic Phase (S.T.O.P.®) technology that provide a dynamic optical cue against single vision spectacle lenses. Second, to compare the rate of myopia progression of spectacle films using S.T.O.P.® technology that provide a dynamic optical cue against spectacle films using S.T.O.P.® technology that provide a static optical cue. A dynamic optical cue is one that changes, and a static optical cue is one that does not change.
Eligibility
Sex
ALL
Min age
6 Years
Max age
14 Years
Healthy volunteers
No
Inclusion Criteria:
* Be between 6-14 years inclusive at time of enrolment.
* Have:
* Read the Informed Assent.
* Been explained the Informed Assent.
* Indicated an understanding of the Informed Assent.
* Signed the Informed Assent.
* Have their parent / legal guardian:
* Read the Informed Consent.
* Been explained the Informed Consent.
* Indicated an understanding of the Informed Consent.
* Signed the Informed Consent.
* Along with their parent / legal guardian, be capable of comprehending the nature of the study, and be willing and able to adhere to study requirements.
* Along with their parent / legal guardian, agree to maintain the visit and prescribed wearing schedule.
* Agree to wear allocated spectacles for a minimum of 5 days per week, at least 6 hours per day for the duration of the study and to inform the investigator if their schedule is interrupted.
* Possess wearable and visually functioning spectacles.
* Be in good general health, based on the parent's / legal guardian's knowledge.
* Have best-corrected high contrast visual acuity based on manifest refraction of 0.10 logMAR (20/25, 6/7.6) or better in each eye.
* Meet the following criteria determined by cycloplegic autorefraction at Baseline:
* -5.00 D ≤ spherical equivalent ≤ -0.75 D and sphere component ≤ -0.50 DS.
* -1.50 DC ≤ astigmatic component ≤ 0 DC.
* \|Spherical equivalent anisometropia\| ≤ 1.00 D.
Exclusion Criteria:
* Participant is currently, or within 30 days prior to this study, has been an active participant in another study.
* Current or prior use of ANY form of myopia control, including but not limited to:
* Optical devices:
* Bifocal or multifocal spectacles of any type.
* Bifocal or multifocal contact lenses of any type.
* Orthokeratology of any type.
* Pharmacological agents:
* Atropine with a concentration \> 0.01%. Participants who have previously used 0.01% atropine are eligible for this study provided they agree not to use 0.01% atropine for at least 30 days before baseline and at any time during the study.
* Pirenzepine
* Participant born earlier than 30 weeks or weighed \< 1500 g at birth.
* A verbal report from the participant's parent / legal guardian is sufficient.
* Habitual use of a systemic or topical medication that may alter normal ocular findings / is known to affect a participant's ocular health / physiology either in an adverse or beneficial manner at enrolment and / or during the clinical trial.
* A known allergy to sodium fluorescein, benoxinate, proparacaine, tropicamide, or cyclopentolate.
* Strabismus as determined by cover test at distance (≥ 3 m) or near (40 cm) while wearing distance correction under non-cycloplegic conditions.
* Known ocular or systemic disease, such as but not limited to:
* Diabetes.
* Graves' disease.
* Glaucoma.
* Uveitis.
* Scleritis.
* Auto immune diseases such as ankylosing spondylitis, multiple sclerosis, Sjogrens syndrome, and systemic lupus erythematosus.
* Any ocular, systemic, or neuro-developmental conditions that could influence refractive development, such as but not limited to:
* Persistent pupillary membrane.
* Vitreous haemorrhage.
* Cataract.
* Central corneal scarring.
* Eyelid haemangiomas.
* Marfan's syndrome.
* Down's syndrome.
* Ehler's-Danlos syndrome.
* Stickler's syndrome.
* Ocular albinism.
* Retinopathy of prematurity.
* Keratoconus or irregular cornea.
* The investigator may, at their discretion, exclude anyone who they believe may not be able to fulfil the clinical trial requirements or it is believed to be in the participant's best interests.
Primary outcome measure(s)
Axial length — Baseline, First Dispense (up to 26 days from Baseline), then 1 month, 4 months, and 6 months after First Dispense Difference in change from Baseline in axial length between single vision (control) and S.T.O.P.® Kit 1 \& 2 (tests)
Axial length — Second Dispense (up to 392 days from Baseline), then 6 months, 12 months, and 18 months after Second Dispense Difference in change from Second Dispense in axial length between static optical cue (control) and dynamic optical cue (test)
This page summarises publicly available registry data for informational purposes — not medical advice. Eligibility is determined by each study team; patients should discuss participation with their clinician.
We use cookies to analyse site traffic and improve your experience. With your consent, we may also use cookies for advertising. You can change your choice at any time.