Heart Failure and Reduced Ejection FractionNYHA Class III Heart Failure
Investigational drug(s) / intervention(s)
Cardiac Contractility Modulation (CCM)
Cardiac Contractility Modulation (CCM): CCM is a therapy delivered via the Optimizer System, which is implanted in eligible heart failure patients. The device delivers non-excitatory electrical signals to the heart during the absolute refractory period, enhancing the strength of cardiac contractions without increasing myocardial oxygen consumption.
Study summary
The purpose of this prospective, multi-center, propensity-matched coverage with evidence development (CED) study is to assess the impact of cardiac contractility modulation (CCM) on mortality and heart failure hospitalizations in Medicare-eligible patients with heart failure who meet indications for CCM.
Eligibility
Sex
ALL
Min age
18 Years
Max age
—
Healthy volunteers
No
Inclusion Criteria
1. Continuous representation in the database in the year prior to index.
2. Age 18 or older will be enrolled in either the treatment or control arm of the study.
3. NYHA III heart failure,
4. Not receiving CRT
5. EF 25 - 45%, inclusive.
6. Remain symptomatic despite at least 3 months of optimized guideline-directed medical therapy (GDMT) as determined by the heart team prior to CCM implantation.
Exclusion Criteria
1. Subject has had a prior heart transplant
2. Subject with mechanical tricuspid valve.
3. Subject has a left ventricular assist device (LVAD).
Primary outcome measure(s)
Time to first heart failure hospitalization or all-cause death — Up to 2 years post-index date for each patient; follow-up will continue until 2 years after the last patient is enrolled to allow at least 2 years of observation for all participants. Time from index date to the first occurrence of either heart failure-related hospitalization or death in patients with a clinical indication for cardiac contractility modulation (CCM) therapy. Outcomes will be compared between patients implanted with the Optimizer System (treatment arm) and a propensity score-matched control group of patients who are eligible for CCM but did not receive the device. Data will be collected from a large, de-identified, multi-system electronic health record database representing diverse sites of care across the United States.
This page summarises publicly available registry data for informational purposes — not medical advice. Eligibility is determined by each study team; patients should discuss participation with their clinician.