Ireland
--:--IST
Latest
Astellas Expands Its 330 Million Euro Tralee Biopharma Facility with a Second Aseptic Filling Line to Double Drug-Product Capacity Xeolas Pharmaceuticals Opens 158,000 Sq Ft State-of-the-Art Baldoyle Facility to Scale Specialty Medicine Manufacturing Priya Life Science Partners with Fleming for the 9th Annual Corporate Compliance & Transparency in Life Sciences Summit in Zurich Ireland Has the Capital and the Lessons: Digital Project Management Is How They Become Delivery Dunbar Pharma Brings First Plant-Derived Dronabinol API to UK Market Through IPS Pharma Leveraging Priya Life Science as a Data Tracker: The Ultimate Use Case & Career Guide The €100K Reality Check: Why a Six-Figure Pharma Salary in Ireland Feels Different Than in Switzerland or Germany Ireland's €93.8 Billion Non-EU Pharma Export Engine: 2025 Eurostat Trade Data and Economic Impact Astellas Expands Its 330 Million Euro Tralee Biopharma Facility with a Second Aseptic Filling Line to Double Drug-Product Capacity Xeolas Pharmaceuticals Opens 158,000 Sq Ft State-of-the-Art Baldoyle Facility to Scale Specialty Medicine Manufacturing Priya Life Science Partners with Fleming for the 9th Annual Corporate Compliance & Transparency in Life Sciences Summit in Zurich Ireland Has the Capital and the Lessons: Digital Project Management Is How They Become Delivery Dunbar Pharma Brings First Plant-Derived Dronabinol API to UK Market Through IPS Pharma Leveraging Priya Life Science as a Data Tracker: The Ultimate Use Case & Career Guide The €100K Reality Check: Why a Six-Figure Pharma Salary in Ireland Feels Different Than in Switzerland or Germany Ireland's €93.8 Billion Non-EU Pharma Export Engine: 2025 Eurostat Trade Data and Economic Impact
Enrolling by invitation Observational

A Review of Precice Intramedullary Limb Lengthening (IMLL) System for Limb Lengthening Procedures in Children.

NCT06714110 · tracked via the Priya Life Science USA tracker
Sponsor
Phase
Observational
Started
2025-03-13
Last updated
2025-12-22

Condition(s) studied

Limb Length Discrepancy

Investigational drug(s) / intervention(s)

Intramedullary Limb Lengthening DeviceExternal Fixator Limb Lengthening Device

Intramedullary Limb Lengthening Device: The Precice IMLL System is composed of the Precice nail, screws, and uses an external remote controller (ERC) for rod distraction. The Precice IMLL System is designed to fit the anatomy of long bones and is intended to be placed internally in an intramedullary manner. It achieves limb correction through gradual lengthening or compression and providing intramedullary fixation for fractures of long bones.

External Fixator Limb Lengthening Device: External fixator devices consist of an external frame (ring, half-ring, monolateral, and rail); bone fixation is accomplished by the transcutaneous bone fixations implants (pins, wires, cables, screws), and the lengthening is accomplished by the vertical components (struts). Generally, femoral lengthening devices are monolateral and tibial lengthening devices have ring or half-ring frames. The external fixators are made of a variety of materials, including stainless steel, titanium, carbon fiber, and aluminum.

Study summary

This study will look at how safe and effective limb lengthening surgeries are for the femur and tibia in children 12 years old and younger. We will examine any complications from the surgery, the results of X-rays, and feedback from patients. The study will involve the Precice Intramedullary Limb Lengthening (IMLL) System and external fixator devices for limb lengthening.

Eligibility

Sex
ALL
Min age
0 Months
Max age
12 Years
Healthy volunteers
No
Inclusion Criteria: * All potential index surgeries must meet the inclusion criteria below in order to be considered for enrollment: 1. Patient was 12 years of age or younger at the time of the index surgery. 2. Diagnosis of femoral or tibial limb length discrepancy greater than or equal to 2.0 cm. 3. Limb length discrepancy secondary to congenital or acquired etiologies. 4. Patients received limb lengthening treatment of the femur or tibia with the Precice IMLL System or an external fixator limb lengthening device. 5. Minimum medullary canal diameter ≥6 mm in the treated bone - Precice IMLL System treatment group only. 6. Closed or nonfunctioning physeal growth plates in the treated bone - Precice IMLL System treatment group only. 7. Minimum of 12 months of follow-up. 8. Available medical and radiographic records preoperatively through consolidation. Exclusion Criteria: * Index surgeries will be excluded from consideration for the study if they meet any of the following criteria: 1. Patients with unresolved limb lengthening-related adjacent joint contractures (loss of range of motion), subluxation, or dislocation prior to the index surgical procedure. 2. Patients with uncorrected coronal or sagittal plane angular malalignment following the index surgical procedure. 3. Patients with unresolved complications related to previous limb lengthening on the index or different limbs, including unhealed pin sites and/or residual bone infection (from external fixator devices) on the index limb. 4. Patients with femoral head osteonecrosis from a previous implantation of a femoral nail prior to the index surgical procedure. 5. Patients with a previous implantation of a femoral or tibial nail across an open physeal growth plate prior to the index surgical procedure.

Primary outcome measure(s)

  • Bone (femur or tibia) lengthening — At least 1 yr post-op
    Achievement of targeted limb length
  • Osteotomy Healing — At least 1 yr post-op
    Assessment of osteotomy healing using the following descriptors: * Premature healing: Defined as osteotomy healing before the target length is achieved. * Healed (consolidated): Defined as the presence of full corticalization (ossified) of regenerate bone of three of four cortices seen on AP and lateral radiographs. * Delayed union (consolidation): Defined as bone union taking greater than 6 months but with progressive improvement on radiographs and the osteotomy eventually healed. * Partial union (consolidation): Defined as incomplete bone healing, i.e., radiographic healing at only 1 or 2 cortices on AP and lateral views. * Nonunion (pseudarthrosis): Defined as lack of complete healing within 6 months of the end of the lengthening period.
  • Frequency of device related complications — Post-op through at least 1 year post-op
    Review of investigator-reported device-related complications

Trial sites (1)

FacilityCityRegionStatus
Paley Institute West Palm Beach Florida

Other trials for the same condition

Official registry record

This page summarises publicly available registry data for informational purposes — not medical advice. Eligibility is determined by each study team; patients should discuss participation with their clinician.

View NCT06714110 on ClinicalTrials.gov ↗ ← All trials in the USA