Clinical Trials in China / NCT05803564
Recruiting Not applicable

Thoracoabdominal Aortic Stent System for Endovascular Treatment of Thoracoabdominal Aortic Dissecting Aneurysm.

NCT05803564 · tracked via the Priya Life Science China tracker
Sponsor
Lifetech Scientific (Shenzhen) Co., Ltd.
Phase
Not applicable
Started
2021-10-01
Last updated
2025-06-22

Condition(s) studied

Thoracoabdominal; Aortic, Aneurysm, Dissecting

Investigational drug(s) / intervention(s)

Thoracoabdominal aortic stent system

Thoracoabdominal aortic stent system: Patients who meet all the inclusion criteria and don't meet the exclusion criteria will be implanted with thoracoabdominal aortic stent system.

Study summary

A First in man study to evaluate the safety and efficacy of thoracoabdominal aortic stent system for endovascular treatment of thoracoabdominal aortic dissecting aneurysm.

Eligibility

Sex
ALL
Min age
18 Years
Max age
80 Years
Healthy volunteers
No
Inclusion Criteria: 1. Patients aged greater than 18 years old and less than 80 years old; 2. Patients diagnosed with thoraco-abdominal aortic dissecting aneurysm and at least one of the following conditions should be met: a)Maximum aneurysm diameter \>50 mm; b)Increase in diameter by more than 5 mm in recent 6 months c)Symptoms such as abdominal pain and back pain associated with thoracic and abdominal aortic dissecting aneurysm were identified. d)Poor morphology of thoracic and abdominal aortic dissecting aneurysm; e)Aortic dissection tears to iliac artery resulting in common iliac artery dissection tumor diameter \>40 mm; 3. Anatomic criteria a)The diameter of the proximal anchoring area (aorta or implanted graft) ranged from 17\~36 mm to ≥25 mm in length; b)Distal anchoring area (aorta or implanted graft): If distal anchoring area is in iliac artery, anchoring area diameter range 7\~25 mm, length ≥15 mm; If the distal anchoring area is in the abdominal aorta, the anchoring area has a diameter of 12\~36 mm and a length of ≥20 mm; c)There is a normal anchoring area at the distal end of the visceral branch vessel. The diameter range of the anchoring area is 6\~13 mm and the length is ≥15 mm. d)Normal anchoring zone at distal renal artery, anchoring zone diameter 4.5\~9 mm, length ≥15 mm; e)Suitable iliac, femoral, and upper limb arterial access. 4. Patients who understand the purpose of the trial, volunteer to participate and sign the informed consent form, and are willing to complete follow-up as required by the protocol; Exclusion Criteria: 1. Patients with severe hematoma in aortic wall in proximal anchoring area of stent 2. Patients requiring simultaneous coverage and embolization of bilateral internal iliac arteries; 3. Patients with a history of acute coronary syndrome within 6 months; Acute coronary syndromes are cardiac acute ischemic syndromes resulting from rupture of an unstable atherosclerotic plaque in the coronary artery or erosion secondary to the formation of new blood 4 thrombus, including ST-elevation myocardial infarction, non-ST-elevation myocardial infarction, and unstable angina. 4. Patients with a transient ischemic attack (TIA) or ischemic/hemorrhagic stroke within 3 months; 5. Patients with preoperative hepatic and renal dysfunction \[alanine aminotransferase (ALT) or aspartate aminotransferase (AST) \> 5 times the normal upper limit; Serum creatinine (Cr) \>150u mol/L\]; 6. Patients with severe pulmonary insufficiency who cannot tolerate general anesthesia; 7. Patients with severe coagulopathy; 8. Patients with a history of hypersensitivity to contrast agents, anticoagulants, antiplatelet agents, stent delivery devices (i.e., nitinol, polyester, PTFE, nylon polymer materials); 9. Patients with connective tissue diseases such as systemic lupus erythematosus, Marfan syndrome, Egyptian syndrome, or Behcet's disease; 10. Patients with arteritis; 11. Patients with significant organ dysfunction or other serious disease; 12. Women with planned pregnancy, pregnancy stage , or lactation; 13. The patient participated in another clinical trial and was not out or withdrawn within the first 3 months of the screening period of this trial. 14. Patients with a life expectancy of not more than 1 year; 15. Patients judged by the investigator to be unsuitable for endovascular treatment;

Primary outcome measure(s)

Trial sites (1)

FacilityCityRegionStatus
Chinese PLA General Hospita Beijing Beijing Municipality Recruiting

More Lifetech Scientific (Shenzhen) Co., Ltd. trials in China

Official registry record

This page summarises publicly available registry data for informational purposes — not medical advice. Eligibility is determined by each study team; patients should discuss participation with their clinician.

View NCT05803564 on ClinicalTrials.gov ↗ ← All trials in China