VitaFlow™ II Transcatheter Aortic Valve System: VitaFlow™ II Transcatheter Aortic Valve System contains a valve stent-VitaFlow™ Aortic Valve, a delivery system-VitaFlow™ Delivery System, loading tools, and a guide-wire
Study summary
This is a pre-market clinical investigation aiming to evaluate the safety and effectiveness of Microport™ CardioFlow VitaFlow™ II Transcatheter Aortic Valve System for the treatment of severe aortic stenosis.
Eligibility
Sex
ALL
Min age
70 Years
Max age
—
Healthy volunteers
No
Inclusion Criteria:
1. Age≥70 years;
2. Symptomatic , severe, aortic valve stenosis : peak velocity ≥4.0m/s, or mean transvalvular gradient ≥40mmHg(1 mmHg=0.133kPa), or effective orifice area\<0.8cm² (or EOA index\<0.5cm²/m²);
3. NYHA≥II class;
4. Estimated life-expectancy\>12 months after implantation of the prosthetic valve;
5. Anatomically suitable for the transcatheter aortic valve implantation procedure;
6. The patients considered to high-risk or not suitable for surgical aortic valve replacement (SAVR), as assessed by two or above heart surgeons; The patient has been informed of the nature of the study, is willing to enroll in the study by signing a patient informed consent and agreeing to the scheduled follow up requirement.
Exclusion Criteria:
1. Acute myocardial infarction (MI) in last 30 days before the treatment;
2. Aortic root anatomy not suitable for the implantation of the transcatheter aortic valve;
3. Complicated lesion of the aortic valve (aortic stenosis with severe regurgitation); moderate-severe mitral valve stenosis; severe mitral valve regurgitation; severe tricuspid valve regurgitation;
4. Previous implantation of heart valve at any position;
5. Hemodynamic instability requiring mechanical hemodynamic support devices;
6. Need for emergency surgery for any reason;
7. Hypertrophic cardiomyopathy with obstruction;
8. Severe left ventricular dysfunction with left ventricular ejection fraction (LVEF) \< 20%;Severe right ventricular dysfunction;
9. Active peptic ulcer or upper gastro-intestinal bleeding within the past 3 months;
10. Known hypersensitivity or contraindication to all anticoagulation/antiplatelet regimens, to nitinol, contrast media or other relevant elements.
11. Congenital aortic valve stenosis or unicuspid aortic valve;
12. Vascular diseases or anatomical condition preventing the device access;
13. Active endocarditis or other active infections at the time of treatment;
14. Participating in another trial and the primary endpoint is not achieved.
15. Inability to comply with the clinical investigation follow-up or other requirements.
Primary outcome measure(s)
Rate of all-cause mortality at 12 months post implantation — 12 months post implantation Rate of all-cause mortality including cardiovascular and non-cardiovascular death
Trial sites (4)
Facility
City
Region
Status
Fuwai Hospital
Beijing
Beijing Municipality
Recruiting
Zhongshan Hospital
Shanghai
Shanghai Municipality
Recruiting
West China Hospital of Sichuan University
Chengdu
Sichuan
Recruiting
The Second Affiliated Hospital Zhejiang University School of Medicine
Hangzhou
Zhejiang
Recruiting
More Shanghai MicroPort CardioFlow Medtech Co., Ltd. trials in China