Clinical Trials in China / NCT04414878
Recruiting Not applicable

VitaFlow™ II Transcatheter Aortic Valve System Pre-market Trial

NCT04414878 · tracked via the Priya Life Science China tracker
Sponsor
Shanghai MicroPort CardioFlow Medtech Co., Ltd.
Phase
Not applicable
Started
2018-01-31
Last updated
2020-06-04

Condition(s) studied

Aortic Stenosis

Investigational drug(s) / intervention(s)

VitaFlow™ II Transcatheter Aortic Valve System

VitaFlow™ II Transcatheter Aortic Valve System: VitaFlow™ II Transcatheter Aortic Valve System contains a valve stent-VitaFlow™ Aortic Valve, a delivery system-VitaFlow™ Delivery System, loading tools, and a guide-wire

Study summary

This is a pre-market clinical investigation aiming to evaluate the safety and effectiveness of Microport™ CardioFlow VitaFlow™ II Transcatheter Aortic Valve System for the treatment of severe aortic stenosis.

Eligibility

Sex
ALL
Min age
70 Years
Max age
Healthy volunteers
No
Inclusion Criteria: 1. Age≥70 years; 2. Symptomatic , severe, aortic valve stenosis : peak velocity ≥4.0m/s, or mean transvalvular gradient ≥40mmHg(1 mmHg=0.133kPa), or effective orifice area\<0.8cm² (or EOA index\<0.5cm²/m²); 3. NYHA≥II class; 4. Estimated life-expectancy\>12 months after implantation of the prosthetic valve; 5. Anatomically suitable for the transcatheter aortic valve implantation procedure; 6. The patients considered to high-risk or not suitable for surgical aortic valve replacement (SAVR), as assessed by two or above heart surgeons; The patient has been informed of the nature of the study, is willing to enroll in the study by signing a patient informed consent and agreeing to the scheduled follow up requirement. Exclusion Criteria: 1. Acute myocardial infarction (MI) in last 30 days before the treatment; 2. Aortic root anatomy not suitable for the implantation of the transcatheter aortic valve; 3. Complicated lesion of the aortic valve (aortic stenosis with severe regurgitation); moderate-severe mitral valve stenosis; severe mitral valve regurgitation; severe tricuspid valve regurgitation; 4. Previous implantation of heart valve at any position; 5. Hemodynamic instability requiring mechanical hemodynamic support devices; 6. Need for emergency surgery for any reason; 7. Hypertrophic cardiomyopathy with obstruction; 8. Severe left ventricular dysfunction with left ventricular ejection fraction (LVEF) \< 20%;Severe right ventricular dysfunction; 9. Active peptic ulcer or upper gastro-intestinal bleeding within the past 3 months; 10. Known hypersensitivity or contraindication to all anticoagulation/antiplatelet regimens, to nitinol, contrast media or other relevant elements. 11. Congenital aortic valve stenosis or unicuspid aortic valve; 12. Vascular diseases or anatomical condition preventing the device access; 13. Active endocarditis or other active infections at the time of treatment; 14. Participating in another trial and the primary endpoint is not achieved. 15. Inability to comply with the clinical investigation follow-up or other requirements.

Primary outcome measure(s)

Trial sites (4)

FacilityCityRegionStatus
Fuwai Hospital Beijing Beijing Municipality Recruiting
Zhongshan Hospital Shanghai Shanghai Municipality Recruiting
West China Hospital of Sichuan University Chengdu Sichuan Recruiting
The Second Affiliated Hospital Zhejiang University School of Medicine Hangzhou Zhejiang Recruiting

More Shanghai MicroPort CardioFlow Medtech Co., Ltd. trials in China

Other trials for the same condition

Official registry record

This page summarises publicly available registry data for informational purposes — not medical advice. Eligibility is determined by each study team; patients should discuss participation with their clinician.