Ireland
--:--IST
Latest
Astellas Expands Its 330 Million Euro Tralee Biopharma Facility with a Second Aseptic Filling Line to Double Drug-Product Capacity Xeolas Pharmaceuticals Opens 158,000 Sq Ft State-of-the-Art Baldoyle Facility to Scale Specialty Medicine Manufacturing Priya Life Science Partners with Fleming for the 9th Annual Corporate Compliance & Transparency in Life Sciences Summit in Zurich Ireland Has the Capital and the Lessons: Digital Project Management Is How They Become Delivery Dunbar Pharma Brings First Plant-Derived Dronabinol API to UK Market Through IPS Pharma Leveraging Priya Life Science as a Data Tracker: The Ultimate Use Case & Career Guide The €100K Reality Check: Why a Six-Figure Pharma Salary in Ireland Feels Different Than in Switzerland or Germany Ireland's €93.8 Billion Non-EU Pharma Export Engine: Trade Data, Destination Markets, and Economic Impact Astellas Expands Its 330 Million Euro Tralee Biopharma Facility with a Second Aseptic Filling Line to Double Drug-Product Capacity Xeolas Pharmaceuticals Opens 158,000 Sq Ft State-of-the-Art Baldoyle Facility to Scale Specialty Medicine Manufacturing Priya Life Science Partners with Fleming for the 9th Annual Corporate Compliance & Transparency in Life Sciences Summit in Zurich Ireland Has the Capital and the Lessons: Digital Project Management Is How They Become Delivery Dunbar Pharma Brings First Plant-Derived Dronabinol API to UK Market Through IPS Pharma Leveraging Priya Life Science as a Data Tracker: The Ultimate Use Case & Career Guide The €100K Reality Check: Why a Six-Figure Pharma Salary in Ireland Feels Different Than in Switzerland or Germany Ireland's €93.8 Billion Non-EU Pharma Export Engine: Trade Data, Destination Markets, and Economic Impact
Starting soon Not applicable

Self-Expanding Hydra Transcatheter Heart Valve (THV) Series Versus Balloon-Expandable Devices for Valve-In-Valve Transcatheter Aortic Valve Implantation (TAVI) for Patients With Failed Surgical Aortic Bioprosthesis.

NCT07524595 · tracked via the Priya Life Science Ireland tracker
Phase
Not applicable
Started
2026-04
Last updated
2026-04-13

Condition(s) studied

AORTIC VALVE DISEASESValve-in-valve ProceduresSurgical Valve ReplacementValve Disease, Aortic

Investigational drug(s) / intervention(s)

Hydra THV SeriesSapien THV Series and MyVal THV Series

Hydra THV Series: Transcatheter Aortic Valve Implantation (TAVI) for Patients with Failed Surgical Aortic Bioprosthesis with the use of Hydra THV Series

Sapien THV Series and MyVal THV Series: Transcatheter Aortic Valve Implantation (TAVI) for Patients with Failed Surgical Aortic Bioprosthesis with the use of Sapien THV Series and MyVal THV Series

Study summary

This is a prospective, randomised, international, multicentre, open-label, investigator-initiated study in patients undergoing valve-in-valve Transcatheter Aortic Valve Implantation (TAVI) for failed surgical aortic bioprosthesis. A total of 111 patients will be randomized in a 2:1 ratio, with 74 patients assigned to self-expanding Hydra THV Series and 37 patients assigned to BEV (Sapien THV Series and MyVal THV Series).

Eligibility

Sex
ALL
Min age
18 Years
Max age
—
Healthy volunteers
No
"Inclusion Criteria": 1. Male or Female patient ≥18 years of age 2. Severe hemodynamic valve deterioration of a surgically implanted bioprosthetic aortic valve, including severe valve stenosis and/or severe valve regurgitation, as determined by the Heart Team assessment 3. Patients eligible for transfemoral TAVI with both study THV platforms per heart team consensus. 4. TAVI (with or without fracture of surgical valve) is suitable with commercially available sizes of both Hydra and Sapien/Myvall BEVs. 5. Patient has been informed of the nature of the study and agrees to its provisions and has provided written informed consent as approved by the Ethics Committee and is willing to comply with all protocol-required (follow-up) evaluations. "Exclusion criteria": 1. Patients unwilling to provide an informed consent, or whose legal representative object to their participation in the study 2. Patient is a woman who is pregnant or nursing (a pregnancy test must be performed within 7 days prior to the index procedure in woman of child-bearing potential according to local practice) 3. Patients with non-transfemoral TAVI access. 4. Surgical or transcatheter valve in mitral position (mitral rings are not an exclusion) 5. Patients who had received the Bentall procedure. 6. Patients with active bacterial endocarditis or ongoing sepsis ≤6 months prior to the index procedure 7. Echocardiographic evidence of intracardiac mass, thrombus or vegetation 8. Acute myocardial infarction ≤30 days before the intended TAVI procedure 9. Known hypersensitivity or contraindication to antithrombotic therapy (or inability to be anticoagulated during the procedure), nitinol, or sensitivity to contrast media which cannot be adequately pre-medicated 10. Patients with severe left ventricular dysfunction and ejection fraction \<30% or hemodynamic instability requiring inotropic agent or mechanical support. 11. Patients with significant renal insufficiency (serum creatinine \>3.0 mg/dL (265.5μmol/L)) and/or end stage renal disease requiring chronic dialysis 12. Patients who are at very high risk of coronary obstruction (e.g., VIVID classification IIB, IIIB, IIIC) and are judged by the heart team to require upfront leaflet laceration (e.g. Basilica or Unicorn procedure) or chimney or snorkel stenting as part of the TAVI procedure. 13. Any planned surgical or peripheral procedure to be performed in next 30-day after the index procedure 14. Life expectancy \<12 months due to non-cardiac co-morbid conditions including carcinomas, chronic liver disease, chronic renal disease or chronic end-stage pulmonary disease

Primary outcome measure(s)

  • Mean pressure gradient across the aortic valve. — 30 Days
    The objective is to demonstrate that the self-expanding Hydra THV series is non-inferior, and potentially superior, to balloon-expandable valves (Sapien and MyVal THV series) in terms of hemodynamic performance for patients undergoing ViV TAVI for failed surgical aortic bioprostheses.

Trial sites (1)

FacilityCityRegionStatus
University of Galway Galway Ireland
Official registry record

This page summarises publicly available registry data for informational purposes — not medical advice. Eligibility is determined by each study team; patients should discuss participation with their clinician.

View NCT07524595 on ClinicalTrials.gov ↗ ← All trials in Ireland