# Priya Life Science - Full Knowledge Base This document contains the complete, unabridged technical knowledge base and glossary of Priya Life Science. ## Pharma Glossary ### ADR Adverse Drug Reaction. **Local Context:** A response to a medicinal product which is noxious and unintended, where a causal relationship between product and event is suspected. ### AE Adverse Event. **Local Context:** Any untoward medical occurrence in a patient or subject administered a drug. Reports are managed in the EU via EudraVigilance. ### ALCOA+ Data Integrity guidelines specifying that records must be Attributable, Legible, Contemporaneous, Original, Accurate, Complete, Consistent, Enduring, and Available. **Local Context:** Regulatory agencies like the HPRA place massive audit focus on ALCOA+ compliance to ensure patient safety and product quality. ### Annex 1 The section of the EU Good Manufacturing Practice (GMP) guidelines governing the manufacture of sterile medicinal products. **Local Context:** A major revision of Annex 1 came into operation in August 2023, introducing stricter requirements for contamination control strategy (CCS). ### ASMF Active Substance Master File. **Local Context:** A submission to regulatory authorities providing confidential detailed information about the manufacture and control of an active substance (API). ### ATMP Advanced Therapy Medicinal Product. **Local Context:** Medicinal products based on gene therapy, somatic cell therapy, or tissue engineering. Evaluated centrally by the EMA Committee for Advanced Therapies (CAT). ### Audit Trail A secure, computer-generated, time-stamped electronic record that allows for the reconstruction of the course of events relating to data entry or modification. **Local Context:** Mandatory under EU GMP Annex 11 (Computerised Systems) to ensure data transparency. ### Benefit-Risk Balance The relationship between the positive therapeutic effects of a product compared to its risks (safety issues). **Local Context:** Regulators continuous evaluate this balance; a negative shift can lead to drug suspension or withdrawal. ### Bioprocess Operator A technical specialist responsible for monitoring bioreactors, filtration systems, and cleanroom biomanufacturing lines. **Local Context:** One of the most in-demand vocational roles in Ireland's biopharma hubs. ### Bioreactor An engineered vessel or device that supports a biologically active environment for growing cells or organisms. **Local Context:** Biologics hubs in Ireland (like Pfizer Grange Castle and Eli Lilly Limerick) utilize massive bioreactors for antibody production. ### Biosimilar A biological medicine highly similar to another already approved biological medicine (the reference product). **Local Context:** Regulated in Europe via strict comparative clinical and quality testing to establish therapeutic equivalence. ### Calibration The demonstration that a particular instrument or device produces results within specified limits by comparison with those produced by a standard. **Local Context:** Calibration schedules must be strictly maintained and logged to avoid quality deviations. ### CAPA Corrective and Preventive Action. **Local Context:** A system used to investigate, root cause, and eliminate the recurrence of quality issues. Mandatory under EU GMP Chapter 1. ### CAR-T Therapy Chimeric Antigen Receptor T-cell therapy. A type of immunotherapy where a patient's T cells are genetically engineered to target cancer cells. **Local Context:** Classified as an ATMP in the EU, requiring complex vein-to-vein logistical tracking and specialized hospital validation. ### Cell Bank A collection of ampoules containing a single pool of cells of uniform composition, stored under deep freeze conditions. **Local Context:** Divided into Master Cell Bank (MCB) and Working Cell Bank (WCB) to ensure consistent cell culture starting materials. ### CEP Certificate of Suitability. **Local Context:** A certificate issued by the EDQM confirming that a substance complies with the monographs of the European Pharmacopoeia. ### cGMP Current Good Manufacturing Practice. **Local Context:** Regulations enforcing proper design, monitoring, and control of manufacturing facilities and processes. Audited directly by the HPRA. ### Change Control A formal quality management system designed to propose, evaluate, review, and execute changes in equipment, processes, or materials. **Local Context:** Required to prevent unauthorized modifications that could compromise the validated status of a manufacturing line. ### CHO Cells Chinese Hamster Ovary cells. **Local Context:** The mammalian cell line most commonly used in industrial biomanufacturing to produce recombinant therapeutic proteins. ### CIOMS Council for International Organizations of Medical Sciences. **Local Context:** An international body that publishes consensus guidelines for drug safety reporting formats (e.g., CIOMS I forms). ### CIP Clean-in-Place. **Local Context:** An automated method of cleaning the interior surfaces of pipes, vessels, process equipment, and filters without disassembly. ### CRA Clinical Research Associate (Monitor). **Local Context:** The professional responsible for monitoring trial sites to ensure compliance with the protocol, GCP guidelines, and regulatory requirements. ### CRF Case Report Form. **Local Context:** A printed, optical, or electronic document designed to record all of the protocol-required information on each trial subject. ### CRISPR Clustered Regularly Interspaced Short Palindromic Repeats. A gene-editing technology allowing precise edits to genomic sequences. **Local Context:** Used extensively in biotechnology R&D hubs in Dublin and Cork to research disease models. ### CRO Contract Research Organisation. **Local Context:** A company providing support services to the pharmaceutical and biotech industries, managing clinical trials on behalf of sponsors. ### CTA Clinical Trial Application. **Local Context:** The formal application requesting approval to conduct a clinical trial in the EU, now submitted via the Clinical Trials Information System (CTIS). ### CTD Common Technical Document. **Local Context:** The internationally agreed format for organizing applications (Modules 1-5) submitted to regulatory authorities. ### CTIS Clinical Trials Information System. **Local Context:** The single-entry portal managed by the EMA for submitting and evaluating clinical trials within the EU/EEA. ### CTR Clinical Trials Regulation (EU No 536/2014). **Local Context:** The harmonized EU regulation that entered into force in 2022, streamlining clinical trial approvals across the entire European Union. ### Deviation An unplanned departure from an approved instruction, SOP, specification, or validation protocol during manufacturing or testing. **Local Context:** All deviations must be documented, risk-assessed, and signed off by the Quality Unit before batch release. ### Double-Blind A trial design where neither the subjects nor the investigators/medical staff know which treatment group patients are assigned to. **Local Context:** Minimizes bias in reporting and clinical evaluation. ### Downstream Processing The purification and recovery of product from cell culture fluid or biological harvests. **Local Context:** Utilizes filtration, chromatography, and viral inactivation steps to isolate pure proteins. ### DSUR Development Safety Update Report. **Local Context:** The safety report submitted annually by sponsors during the clinical trial/development phase of an investigational drug. ### E-E-A-T Experience, Expertise, Authoritativeness, and Trustworthiness. Google's core search quality evaluation framework. **Local Context:** Crucial ranking signal for life science publications in Ireland aiming to rank on Google search for medical and regulatory guidance. ### eCTD Electronic Common Technical Document. **Local Context:** The electronic version of the CTD format, mandatory for all EMA submissions and most national submissions in Europe. ### ELISA Enzyme-Linked Immunosorbent Assay. An analytical biochemistry assay that uses a solid-phase enzyme immunoassay to detect the presence of a ligand. **Local Context:** Frequently used by Quality Control labs in Ireland for checking antibody concentration and purity. ### EMA European Medicines Agency. **Local Context:** The EU body responsible for the scientific evaluation, supervision, and safety monitoring of medicines. Relocated from London to Amsterdam in 2019. ### Embargo A request or agreement that information provided in a press release should not be published by the media until a designated date and time. **Local Context:** Commonly used when distributing clinical trial phase results or regulatory approval announcements in advance to trusted journalists. ### EudraVigilance The central European database managed by the EMA to collect and monitor suspected adverse reactions to medicines. **Local Context:** All marketing authorization holders in Ireland must integrate their safety databases with EudraVigilance. ### Expression System The combination of an expression vector and its host cell used to produce a target recombinant protein. **Local Context:** Includes mammalian (CHO), bacterial (E. coli), and yeast (S. cerevisiae) systems. ### FDA Food and Drug Administration (United States). **Local Context:** The US federal agency regulating food, drugs, and medical devices. HPRA-regulated Irish manufacturing sites exporting to the US are regularly audited by the FDA. ### GAMP 5 Good Automated Manufacturing Practice version 5. A risk-based approach to compliant GxP computerized systems. **Local Context:** The global standard used by QA departments in Ireland to validate software and automated systems. ### GCP Good Clinical Practice. **Local Context:** An international ethical and quality standard for designing, conducting, and reporting clinical trials involving human subjects. ### GLP-1 Glucagon-like peptide-1 receptor agonists. A class of biological drugs used to treat type 2 diabetes and obesity. **Local Context:** Major manufacturing plants in Ireland are expanding lines to support high global demands for these peptides. ### Grade A The high-risk cleanroom grade for aseptic operations, requiring laminar flow and near-zero particle counts. **Local Context:** Regulated under EU GMP Annex 1, requiring active microbial and physical monitoring during all filling processes. ### Grade B The background environment cleanroom grade for Grade A zones in aseptic preparation and filling. **Local Context:** Requires strict personnel gowning and gown validation before entering. ### Grade C Cleanroom grade used for less critical stages of manufacturing, such as preparation of solutions to be filtered. **Local Context:** Requires controlled access and cleanroom clothing standards. ### Grade D Cleanroom grade used for handling less critical materials and equipment cleaning operations. **Local Context:** Acts as the entry barrier cleanroom classification in most Irish biopharma plants. ### Host Cell Proteins Proteins produced by the host cell line during recombinant protein expression that must be purified out of the final product. **Local Context:** Monitored as critical process impurities under EU pharmacopoeia specifications. ### HPRA Health Products Regulatory Authority. **Local Context:** The state agency responsible for regulating medicines, medical devices, and other health products in Ireland. Formerly known as the Irish Medicines Board (IMB). ### HVAC Heating, Ventilation, and Air Conditioning. **Local Context:** Cleanroom air handling systems that control temperature, humidity, and particle counts, using HEPA filters to prevent product contamination. ### ICF Informed Consent Form. **Local Context:** The documentation demonstrating that a subject has voluntarily confirmed their willingness to participate in a trial after being fully informed. ### ICH International Council for Harmonisation. **Local Context:** The global body bringing together regulators and industry to standardize technical requirements for pharmaceutical development (e.g., Q8, Q9, Q10). ### ICSR Individual Case Safety Report. **Local Context:** The standard electronic format used to report a single suspected adverse reaction case associated with a medicine. ### IMP Investigational Medicinal Product. **Local Context:** An active ingredient or placebo being tested or used as a reference in a clinical trial. IMPs must be manufactured under strict EU GMP Volume 4 requirements. ### Investigator Brochure The comprehensive compilation of clinical and non-clinical data on the investigational products under study. **Local Context:** Must be updated annually by the sponsor and provided to principal investigators. ### LIMS Laboratory Information Management System. **Local Context:** Software-based laboratory system that manages sample tracking, test results, instrument integration, and regulatory reporting. ### LSO Local Safety Officer. **Local Context:** The designated pharmacovigilance contact in a specific country, responsible for national reporting and communication with the local regulator (HPRA). ### Lyophilisation Freeze-drying. A low-temperature dehydration process that involves freezing the product, lowering pressure, then removing ice by sublimation. **Local Context:** Highly utilized in Ireland for packaging and stabilizing delicate protein and biologic therapies. ### MAA Marketing Authorization Application. **Local Context:** The application submitted to the EMA or national authorities (like the HPRA) to market a drug within the European Economic Area (EEA). ### MedDRA Medical Dictionary for Regulatory Activities. **Local Context:** The global standard medical terminology used to classify adverse event reports and medical diagnoses. ### Media Fill A process simulation test where a sterile microbiological growth medium is run through the manufacturing line to validate aseptic status. **Local Context:** An essential operational requirement audited strictly by HPRA inspectors to verify cleanroom sterility. ### Media Relations The process of coordinating and building relationships with journalists, editors, and industry publications to secure organic media coverage. **Local Context:** Irish biotechs build media relations with trade publications like FierceBiotech and regional platforms like Priya Life Science to attract venture capital. ### Monoclonal Antibody Monoclonal Antibody (mAb). Laboratory-produced molecules engineered to serve as substitute antibodies that can restore, enhance, or mimic the immune system. **Local Context:** Form the cornerstone of biopharmaceutical manufacturing in Ireland, representing blockbuster treatments like pembrolizumab or adalimumab. ### mRNA Vaccine A vaccine using messenger RNA to instruct cells to produce a protein that triggers an immune response. **Local Context:** Revolutionized drug delivery during the pandemic, leading to significant investment in lipid nanoparticle (LNP) tech in Ireland. ### NREC National Research Ethics Committees of Ireland. **Local Context:** The consolidated Irish ethics review body providing single national ethical opinions for clinical trials and medical devices. ### OOS Out of Specification. **Local Context:** Test results that fall outside the specifications or acceptance criteria established in drug applications or official pharmacopoeias. ### OOT Out of Trend. **Local Context:** A stability or release test result that is within the specification limit but is an atypical outlier compared to previous historical batch data. ### Orphan Drug A medicine developed to treat rare medical conditions that would not be profitable to produce without government assistance or market exclusivity. **Local Context:** In the EU, orphan designation grants 10 years of market exclusivity upon approval to encourage rare disease R&D. ### PAES Post-Authorisation Efficacy Study. **Local Context:** A clinical trial required to address efficacy questions that could not be resolved before marketing authorization. ### PASS Post-Authorisation Safety Study. **Local Context:** A study carried out after a medicine is authorized to identify, characterize, or quantify a safety hazard or evaluate risk management effectiveness. ### PAT Process Analytical Technology. **Local Context:** A system for designing, analyzing, and controlling manufacturing through timely measurements of critical quality and performance attributes. ### Phase I First-in-human clinical testing, typically performed in a small cohort of healthy volunteers (20-100) to evaluate safety and tolerability. **Local Context:** LSO and REC approval is mandatory prior to recruitment. ### Phase II Therapeutic exploratory testing in a cohort of patient volunteers (100-500) to assess efficacy, dosing ranges, and safety. **Local Context:** Conducted across major teaching hospitals in Ireland under principal investigators. ### Phase III Therapeutic confirmatory testing in large, diverse patient populations (1,000-5,000) to confirm clinical efficacy and monitor adverse reactions. **Local Context:** Data from Phase III forms the bulk of the marketing authorization application (MAA). ### Phase IV Post-marketing surveillance studies conducted after a medicine is authorized, evaluating long-term safety and real-world effectiveness. **Local Context:** Often mandated by the EMA as part of post-authorization safety commitments. ### PIL Package Leaflet. **Local Context:** The leaflet included in the medicine box containing information for patients. It must align exactly with the approved SmPC in local languages. ### PIP Paediatric Investigation Plan. **Local Context:** A research and development plan to ensure that necessary data on the safety and efficacy of a medicine in children are gathered. ### Placebo An inactive substance designed to look identical to the active investigational drug, used as a control in trials. **Local Context:** Used to isolate the clinical effect of the active pharmaceutical ingredient. ### Plasmid A small, circular, double-stranded DNA molecule that is distinct from a cell's chromosomal DNA, commonly used as a vector in gene cloning. **Local Context:** Quality control departments validate plasmids for purity and sequence identity before bioprocess scale-up. ### PSUR Periodic Safety Update Report. **Local Context:** A pharmacovigilance document providing an evaluation of the risk-benefit balance of a medicine, submitted at defined time points post-approval. ### Public Relations The strategic practice of managing and disseminating information from an individual or organization to the public to construct a favorable reputation. **Local Context:** For life science firms in Ireland, PR campaigns are regulated by HPRA codes to avoid off-label promotional violations. ### QA Quality Assurance. **Local Context:** The wide-ranging concept covering all matters that individually or collectively influence the quality of a product, ensuring it is fit for its intended use. ### QC Quality Control. **Local Context:** The part of GMP concerned with sampling, specifications, and testing, ensuring that the necessary and relevant tests are actually carried out. ### QP Qualified Person. **Local Context:** A legally mandated role in the EU/EEA. The QP certifies that each batch of medicinal products has been manufactured in accordance with GMP and the marketing authorization. ### QPPV Qualified Person Responsible for Pharmacovigilance. **Local Context:** An EU-mandated executive responsible for the establishment and maintenance of the safety database and system for a marketing authorization holder. ### Qualification The process of testing equipment, utilities, or systems to ensure they work correctly (divided into Installation, Operational, and Performance Qualification). **Local Context:** Qualification (IQ/OQ/PQ) is the precursor to overall process validation. ### REC Research Ethics Committee. **Local Context:** The local or national board of experts reviewing trial protocols to protect the rights, safety, and well-being of trial subjects. ### Recombinant DNA DNA molecules formed by laboratory methods of genetic recombination to bring together genetic material from multiple sources. **Local Context:** Used to engineer host cell lines (like CHO cells) for therapeutic protein synthesis. ### RMP Risk Management Plan. **Local Context:** A detailed description of the risk management system required in the EU for identifying and minimizing the safety risks of a medicine. ### RP Responsible Person. **Local Context:** The person designated at a pharmaceutical wholesale distribution site to ensure that GDP (Good Distribution Practice) requirements are met. ### SAE Serious Adverse Event. **Local Context:** An event resulting in death, life-threatening situation, hospitalization, persistent disability, or congenital anomaly. ### Scientific Advice Formal meetings where developers discuss clinical, non-clinical, or quality testing plans with regulators before submitting marketing applications. **Local Context:** HPRA offers Scientific Advice to Irish life science startups and academic research teams to streamline development. ### Serialization The process of printing unique 2D barcodes and serial numbers on medicine packages for trace-and-track validation. **Local Context:** Mandated in the EU by the Falsified Medicines Directive (FMD) to secure the distribution supply chain. ### Signal Detection The systematic search for new risks or safety changes by looking at adverse event database trends. **Local Context:** EMA mandates ongoing signal detection using global healthcare registry databases. ### Single-Use Technology Disposable manufacturing equipment components (such as bags and connectors) used in place of traditional stainless steel. **Local Context:** Reduces cross-contamination risks and cleaning validation requirements in biopharma facilities. ### SIP Sterilize-in-Place / Steam-in-Place. **Local Context:** An automated thermal method of sterilizing process lines and bioreactors using saturated steam without disassembling the system. ### SmPC Summary of Product Characteristics. **Local Context:** The official document approved by regulators outlining how a medicine should be used safely, forming the basis for the Package Leaflet (PIL). ### SOP Standard Operating Procedure. **Local Context:** Step-by-step instructions compiled by an organization to help workers carry out complex routine operations safely and consistently. ### Thought Leadership The practice of expressing authoritative, original ideas and commentary in a specialized field to establish expertise and credibility. **Local Context:** Highly utilized by Quality Assurance and Regulatory directors on LinkedIn to build site and personal authority. ### Transfection The process of deliberately introducing nucleic acids into eukaryotic cells to alter their genetic makeup. **Local Context:** Crucial step in developing host cell lines for recombinant biomanufacturing. ### Upstream Processing The initial stages of bioprocessing including cell line selection, media preparation, cell inoculation, and growth in bioreactors. **Local Context:** Focuses on optimizing yields before cell harvest and purification. ### Validation Documented evidence providing a high degree of assurance that a specific process, method, or system will consistently produce a product meeting specifications. **Local Context:** Essential for all manufacturing equipment and analytical methods in Ireland. ### Variations Changes made to the parameters of an approved marketing authorization after a medicine is on the market. **Local Context:** Categorized into Type IA (minor, do not require approval), Type IB (minor, require validation), and Type II (major scientific assessment required). ### WFI Water for Injection. **Local Context:** High-purity water used as an excipient or vehicle for parenterals. Under EU pharmacopoeia rules, WFI must meet strict microbial and chemical limits. ## Sterile GMP Knowledge Hub Documents ### Document: FDA 21CFR 211 Complete (FDA) # 21 CFR Parts 210 & 211 — Current Good Manufacturing Practice for Finished Pharmaceuticals: FDA Baseline CGMP Regulations: Organization, Facilities, Production Controls, Laboratory, and Records ## Subpart 0: Overview: Scope, Dual Compliance & Regulatory Architecture (§§ 210.1–211.3) # Section 0: Overview — Scope, Dual Compliance & Regulatory Architecture 21 CFR Parts 210 & 211 — Drug CGMP for Finished Pharmaceuticals | eCFR current as of April 2026 **Federal Food, Drug, and Cosmetic Act (FDCA) — Adulteration Provision:** "A drug shall be deemed to be adulterated… if the methods used in, or the facilities or controls used for, its manufacture, processing, packing, or holding do not conform to or are not operated or administered in conformity with current good manufacturing practice to assure that such drug meets the requirements of this chapter as to safety and has the identity and strength, and meets the quality and purity characteristics, which it purports or is represented to possess." *— FDCA §501(a)(2)(B), 21 U.S.C. §351(a)(2)(B)* This provision is the ultimate enforcement anchor for all CGMP requirements. Any drug product that deviates from CGMP is deemed adulterated under federal law — regardless of whether it actually caused patient harm. --- **21 CFR 210.1 — Status of Current Good Manufacturing Practice Regulations:** "(a) The regulations set forth in this part and in parts 211 through 226 and parts 600 through 680 of this chapter contain the minimum current good manufacturing practice for methods to be used in, and the facilities or controls to be used for, the manufacture, processing, packing, or holding of a drug to assure that such drug meets the requirements of the act as to safety, and has the identity and strength, and meets the quality and purity characteristics that it purports or is represented to possess." "(b) The failure to comply with any regulation set forth in this part and in parts 211 through 226 and parts 600 through 680 of this chapter in the manufacture, processing, packing, or holding of a drug shall render such drug to be adulterated under section 501(a)(2)(B) of the act and such drug, as well as the person who is responsible for the failure to comply, shall be subject to regulatory action." --- **21 CFR 210.2 — Applicability of Current Good Manufacturing Practice Regulations:** "(a) The regulations in this part and in parts 211 through 226 and parts 600 through 680 of this chapter as they may pertain to a drug; (1) apply to all persons who are manufacturers, packers, or holders of such drug marketed in the United States; (2) apply to all drugs…" "(b) Where a person engages in only some operations subject to the regulations in this part, parts 211 through 226 and parts 600 through 680 of this chapter, such person shall comply with the regulations governing those operations." "(c) An investigational drug for use in a Phase 1 study… is subject to legal requirements of the act relating to the safety of the drug product… [The regulations in part 211 do not apply to the manufacture of such investigational drug for human use, except where the investigational drug has been made available for a Phase 2 or Phase 3 investigation…]" --- **21 CFR 210.3 — Definitions:** The following definitions apply to Parts 210 through 226 and Parts 600 through 680 unless the context otherwise requires: Batch A specific quantity of a drug or other material that is intended to have uniform character and quality, within specified limits, and is produced according to a single manufacturing order during the same cycle of manufacture. *(§210.3(b)(2))* Lot A batch, or a specific identified portion of a batch, having uniform character and quality within specified limits; or, in the case of a drug product produced by continuous process, a specific identified amount produced in a unit of time or quantity in a manner that assures its having uniform character and quality within specified limits. *(§210.3(b)(10))* Lot number, control number, or batch number Any distinctive combination of letters, numbers, or symbols, or any combination of them, from which the complete history of the manufacture, processing, packing, holding, and distribution of a batch or lot of drug product or other material can be determined. *(§210.3(b)(11))* Component Any ingredient intended for use in the manufacture of a drug product, including those that may not appear in such drug product. *(§210.3(b)(3))* Drug product A finished dosage form, for example, tablet, capsule, solution, etc., that contains an active drug ingredient generally, but not necessarily, in association with inactive ingredients. The term also includes a finished dosage form that does not contain an active ingredient but is intended to be used as a placebo. *(§210.3(b)(4))* Drug substance An active ingredient that is intended to furnish pharmacological activity or other direct effect in the diagnosis, cure, mitigation, treatment, or prevention of disease or to affect the structure or any function of the body of humans or other animals. The term includes those parts of the molecule that impart the activity and may be modified to form salts, esters, or other noncovalent derivatives used as formulated intermediates. Drug substance does not include intermediates used in the synthesis of such ingredient. *(§210.3(b)(7))* Fiber Any particulate contaminant with a length at least three times greater than its width. *(§210.3(b)(8))* Non-fiber releasing filter Any filter, which after any appropriate pretreatment such as washing or flushing, will not release fibers into the component or drug product that is being filtered. All filters composed of asbestos are deemed to be fiber releasing filters. *(§210.3(b)(13))* In-process material Any material fabricated, compounded, blended, or derived by chemical reaction that is produced for, and used in, the preparation of the drug product. *(§210.3(b)(9))* Strength (1) The concentration of the drug substance (for example, weight/weight, weight/volume, or unit dose/volume basis), and/or (2) The potency, that is, the therapeutic activity of the drug product as indicated by appropriate laboratory tests or by adequately developed and controlled clinical data (expressed, for example, in terms of units by reference to a standard). *(§210.3(b)(16))* Theoretical yield The quantity that would be produced at any appropriate phase of manufacture, processing, or packing of a particular drug product, based upon the quantity of components to be used, in the absence of any loss or error in actual production. *(§210.3(b)(17))* Actual yield The quantity that is actually produced at any appropriate phase of manufacture, processing, or packing of a particular drug product. *(§210.3(b)(1))* Percentage of theoretical yield The ratio of the actual yield (at any appropriate phase of manufacture, processing, or packing of a particular drug product) to the theoretical yield (at the same phase), stated as a percentage. *(§210.3(b)(14))* Active ingredient Any component that is intended to furnish pharmacological activity or other direct effect in the diagnosis, cure, mitigation, treatment, or prevention of disease, or to affect the structure or any function of the body of humans or other animals. The term includes those components that may undergo chemical change in the manufacture of the drug product and be present in the drug product in a modified form intended to furnish the specified activity or effect. *(§210.3(b)(7) — see also drug substance definition)* Inactive ingredient Any component other than an active ingredient. *(§210.3(b)(8) cross-reference)* Acceptance criteria Numerical limits, ranges, or other criteria for acceptance of the results of analytical procedures. While this specific term is defined in ICH Q6A and referenced throughout Part 211 (particularly §§211.160, 211.165, 211.194), Part 210.3 provides the foundational framework under which specification criteria are understood. Acceptance criteria must be established, documented, and consistently applied. *(see §211.160(b))* Expiration date / Expiry The date placed on the label of a drug product designating the time during which a batch of the product is expected to remain within the approved shelf life specifications if stored under defined conditions, and after which it must not be used. Part 211 §211.137 requires expiration dating for drug products. Expiration dating is a prerequisite for certain yield calculations and retention period determinations under §211.180(b). *(§211.137)* Representative sample A sample that consists of a number of units that are drawn based on rational criteria, such as random sampling and intended to assure that the sample accurately portrays the material being sampled. *(§210.3(b)(15))* **Additional Definitions Cross-Referenced in Part 211 (not in §210.3, but important for operational context):** - **Quality control unit (QU)** — defined by function in §211.22: "a unit that has the responsibility and authority to approve or reject all components, drug product containers, closures, in-process materials, packaging material, labeling, and drug products…" - **Out-of-specification (OOS) result** — not in Part 211 text, but addressed in FDA's 2006 OOS Guidance; test result falling outside established specifications (§211.165) or acceptance criteria triggers investigation under §211.192 / §211.194 - **Process validation** — not defined in Part 211, but the concept underlies §§211.100, 211.110, 211.113; defined in FDA's 2011 Process Validation Guidance as collecting and evaluating data from process design through commercial production to establish scientific evidence that a process is capable of consistently delivering a quality product ## Subpart 1: Subparts A–B: Organization, Personnel & QC Unit (§§ 211.1–211.68) (§§ 211.22–211.34) # Section 1: Subparts A–B: Organization, Personnel & QC Unit 21 CFR Parts 210 & 211 — Drug CGMP for Finished Pharmaceuticals | eCFR current as of April 2026 **§ 211.22(a)** — There shall be a quality control unit that shall have the responsibility and authority to approve or reject all components, drug product containers, closures, in-process materials, packaging materials, labeling, and drug products, and the authority to review production records to assure that no errors have occurred or, if errors have occurred, that they have been fully investigated. The quality control unit shall be responsible for approving or rejecting drug products manufactured, processed, packed, or held under contract by another company. **§ 211.22(b)** — Adequate laboratory facilities for the testing and approval (or rejection) of components, drug product containers, closures, packaging materials, in-process materials, and drug products shall be available to the quality control unit. **§ 211.22(c)** — The quality control unit shall have the responsibility for approving or rejecting all procedures or specifications impacting on the identity, strength, quality, and purity of the drug product. **§ 211.22(d)** — Adequate laboratory facilities for the testing and approval (or rejection) of drug products shall be available to the quality control unit. The responsibilities and procedures applicable to the quality control unit shall be in writing; such written procedures shall be followed. **Operational meaning of "written procedures shall be followed" (§211.22(d)):** This clause is deceptively important. It is not enough to have written QCU SOPs — those SOPs must actually be followed in practice. FDA inspectors look for consistency between stated procedure and actual practice. Examples of noncompliance: a written procedure says QCU must review all batch records within 48 hours of completion, but batch records are routinely reviewed weeks later; a SOP mandates QCU signature on all change control approvals, but unsigned change controls are found in files. Gaps between written procedure and practice frequently become Warning Letter content, not merely 483 observations. "The quality control unit shall be responsible for approving or rejecting drug products manufactured, processed, packed, or held under contract by another company." *— 21 CFR §211.22(a), contract manufacturing clause* **Subpart A General Scope — §211.1(a)**: The regulations in this part contain the minimum current good manufacturing practice for preparation of drug products (excluding positron emission tomography drugs) for administration to humans or animals. The failure to comply with any regulation in 21 CFR Part 211 causes a drug product to be adulterated under section 501(a)(2)(B) of the Federal Food, Drug, and Cosmetic Act. **§211.3 — Definitions**: Key terms include: batch (a specific quantity of a drug or other material that is intended to have uniform character and quality); lot (a batch or a specific identified portion of a batch); component (any ingredient intended for use in the manufacture of a drug product); drug product container (any object that holds the drug product); quality control unit (any person or organizational element designated by the firm to be responsible for the duties relating to quality control). **Adulteration consequence of §211.1(a):** The link between CGMP failure and drug adulteration is not merely administrative. Under Section 501(a)(2)(B) of the FD&C Act, a drug product manufactured, processed, packed, or held in conditions that do not conform to CGMP is deemed adulterated — regardless of whether the product itself has any measurable quality defect. This means a drug can be removed from the market, subjected to a recall, and trigger criminal liability for responsible persons, even if laboratory testing shows it meets all specifications. CGMP compliance is not optional because it produces good products; it is legally mandatory because its absence makes the product legally adulterated. **§210 vs §211 — the regulatory relationship:** 21 CFR Part 210 establishes the general CGMP framework and the consequence of non-compliance (adulteration). 21 CFR Part 211 provides the detailed operational requirements. Part 210 §210.2(a) states that the failure to comply with Part 211 constitutes a failure to comply with Part 210 as well — so both parts are triggered together in any enforcement action. Understanding this dual-part structure is important when reading FDA Warning Letters, which may cite both §210 and §211 violations arising from the same observation. ## Subpart 2: Subparts C–D: Buildings, Facilities & Equipment (§§ 211.42–211.72) (§§ 211.42–211.72) # Section 2: Subparts C–D: Buildings, Facilities & Equipment 21 CFR Parts 210 & 211 — Drug CGMP for Finished Pharmaceuticals | eCFR current as of April 2026 **§ 211.42(a)** — Any building or buildings used in the manufacture, processing, packing, or holding of a drug product shall be of suitable size, construction and location to facilitate cleaning, maintenance, and proper operations. **§ 211.42(b)** — Any such building shall have adequate space for the orderly placement of equipment and materials to prevent mix-ups between different components, drug product containers, closures, labeling, in-process materials, or drug products, and to prevent contamination. The flow of components, drug product containers, closures, labeling, in-process materials, and drug products through the building or buildings shall be designed to prevent contamination. **§ 211.42(c)** — Operations shall be performed within specifically defined areas of adequate size. There shall be separate or defined areas or such other control systems for the firm's operations as are necessary to prevent contamination or mix-ups during the course of the following procedures: - (1) Receipt, identification, storage, and withholding from use of components, drug product containers, closures, and labeling, pending the appropriate sampling, testing, or examination by the quality control unit before release for manufacturing or packaging; - (2) Holding of rejected components, drug product containers, closures, and labeling before disposition; - (3) Storage of released components, drug product containers, closures, and labeling; - (4) Storage of in-process materials; - (5) Manufacturing and processing operations; - (6) Packaging and labeling operations; - (7) Quarantine storage before release of drug products; - (8) Storage of drug products after release; - (9) Control and laboratory operations; - (10) Aseptic processing, which includes as appropriate: - (i) Floors, walls, and ceilings of smooth, hard surfaces that are easily cleanable; - (ii) Temperature and humidity controls; - (iii) An air supply filtered through high-efficiency particulate air filters under positive pressure, regardless of whether flow is laminar or nonlaminar; - (iv) A system for monitoring environmental conditions; - (v) A system for cleaning and disinfecting the room and equipment to produce aseptic conditions; - (vi) A system for maintaining any equipment used to control the aseptic conditions. **§ 211.42(d)** — Operations relating to the manufacture, processing, and packing of penicillin shall be performed in facilities separate from those used for other drug products for human use. "An air supply filtered through high-efficiency particulate air filters under positive pressure, regardless of whether flow is laminar or nonlaminar." *— 21 CFR §211.42(c)(10)(iii), the CGMP legal basis for HEPA in aseptic areas* ## Subpart 3: Subparts E–F: Components, Production Controls & Sterile Operations (§§ 211.80–211.115) (§§ 211.80–211.115) # Section 3: Subparts E–F: Components, Production Controls & Sterile Operations 21 CFR Parts 210 & 211 — Drug CGMP for Finished Pharmaceuticals | eCFR current as of April 2026 **§ 211.80 General requirements.** There shall be written procedures describing in sufficient detail the receipt, identification, storage, handling, sampling, testing, and approval or rejection of components and drug product containers and closures; such written procedures shall be followed. **§ 211.82 Receipt and storage of untested components, drug product containers, and closures.** (a) Upon receipt and before testing or examination, each lot of components, drug product containers, and closures shall be quarantined until tested or examined, as appropriate, and released for use. (b) Components, drug product containers, and closures shall be stored under quarantine until they have been tested or examined, as appropriate, and released. Storage within the area used for components, drug product containers, and closures that have been released is permissible if the components are adequately identified as to their status. **§ 211.84 Testing and approval or rejection of components, drug product containers, and closures.** (a) Each lot of components, drug product containers, and closures shall be withheld from use until the lot has been sampled, tested, or examined, as appropriate, and released for use by the quality control unit. (b) Representative samples of each shipment of each lot shall be collected for testing or examination. The number of containers to be sampled, and the amount of material to be taken from each container, shall be based upon appropriate criteria such as statistical criteria for component variability, confidence levels, and degree of precision desired, the past quality history of the supplier, and the quantity needed for analysis and reserve where required by §211.170. (c) Samples shall be examined and tested as follows: - (1) At least one test shall be conducted to verify the identity of each component of a drug product. Specific identity tests, if they exist, shall be used. - (2) Each component shall be tested for conformity with all appropriate written specifications for purity, strength, and quality. In lieu of such testing by the manufacturer, a report of analysis may be accepted from the supplier of a component, provided that at least one specific identity test is conducted on such component by the manufacturer, and provided that the manufacturer establishes the reliability of the supplier's analyses through appropriate validation of the supplier's test methods at appropriate intervals. - (3) Containers and closures shall be tested for conformity with all appropriate written specifications. - (4) When appropriate, components shall be microscopically examined. - (5) Each lot of a component, drug product container, or closure that is liable to contamination with filth, insect infestation, or other extraneous adulterant shall be examined against established specifications for such contamination. (d) Any lot of components, drug product containers, or closures that meets the appropriate written specifications of identity, strength, quality, and purity may be approved and released for use. Any lot of such material that does not meet such specifications shall be rejected. "At least one test shall be conducted to verify the identity of each component of a drug product." *— 21 CFR §211.84(c)(1), the 100% identity testing requirement* **§ 211.86 Use of approved components, drug product containers, and closures.** Components, drug product containers, and closures approved for use shall be rotated so that the oldest approved stock is used first. Deviation from this requirement is permitted if such deviation is temporary and appropriate. **§ 211.87 Retesting of approved components, drug product containers, and closures.** Components, drug product containers, and closures shall be retested or reexamined, as appropriate, for identity, strength, quality, and purity and approved or rejected by the quality control unit in accordance with §211.84 as necessary, e.g., after storage for long periods or after exposure to air, heat, or other conditions that might adversely affect the component, drug product container, or closure. **§ 211.89 Rejected components, drug product containers, and closures.** Rejected components, drug product containers, and closures shall be identified and controlled under a quarantine system designed to prevent their use in manufacturing or processing operations for which they are unsuitable. ## Subpart 4: Subparts G–H: Packaging, Labeling & Distribution (§§ 211.122–211.150) (§§ 211.122–211.150) # Section 4: Subparts G–H: Packaging, Labeling & Distribution 21 CFR Parts 210 & 211 — Drug CGMP for Finished Pharmaceuticals | eCFR current as of April 2026 ## Regulatory Text **§ 211.122(a)** There shall be written procedures describing in sufficient detail the receipt, identification, storage, handling, sampling, examination, and/or testing of labeling and packaging materials; such written procedures shall be followed. Labeling and packaging materials shall be representatively sampled, and examined or tested upon receipt and before use in packaging or labeling of a drug product. **§ 211.122(b)** Any labeling or packaging materials meeting appropriate written specifications may be approved and released for use. Any labeling or packaging materials that do not meet such specifications shall be rejected to prevent their use in operations for which they are unsuitable. **§ 211.122(c)** Records shall be maintained for each shipment received of each different labeling and packaging material indicating receipt, examination or testing, and whether accepted or rejected. **§ 211.122(d)** Labels and other labeling materials for each different drug product, strength, dosage form, or quantity of contents shall be stored separately with suitable identification. Access to the storage area shall be limited to authorized personnel. **§ 211.122(e)** Obsolete and outdated labels, labeling, and other packaging materials shall be destroyed. **§ 211.122(f)** Use of gang-printed labeling for different drug products, or different strengths or net contents of the same drug product, is prohibited unless the labeling from gang-printed sheets is adequately differentiated by size, shape, or color. **§ 211.122(g)** If cut labeling is used, it is subject to the following labeling identity requirements: 1. Separate storage areas or physical segregation of labels from labeling for different drug products, or for different strengths or net contents of the same drug product, to prevent mix-ups. 2. Identification of the drug product, strength, quantity of contents, and lot or control number of the drug product for which the labeling is intended on the containers of cut labeling. **Labeling defined under 21 CFR 201.1 (for context):** - Container labels (primary and secondary) - Package inserts / prescribing information - Carton labeling - Patient medication guides - Any written, printed, or graphic matter accompanying a drug product "Labeling and packaging materials shall be representatively sampled, and examined or tested upon receipt and before use in packaging or labeling of a drug product." — 21 CFR § 211.122(a) ## Subpart 5: Subparts I–K: Laboratory Controls, Records & Complaint Files (§§ 211.160–211.208) (§§ 211.160–211.208) # Section 5: Subparts I–K: Laboratory Controls, Records & Complaint Files 21 CFR Parts 210 & 211 — Drug CGMP for Finished Pharmaceuticals | eCFR current as of April 2026 **§211.160(a) — General requirements:** The establishment of any specifications, standards, sampling plans, test procedures, or other laboratory control mechanisms required by this subpart, including any change in such specifications, standards, sampling plans, test procedures, or other laboratory control mechanisms, shall be drafted by the appropriate organizational unit and reviewed and approved by the quality control unit. The requirements in this subpart shall be followed and shall be documented at the time of performance. Any deviation from the written specifications, standards, sampling plans, test procedures, or other laboratory control mechanisms shall be recorded and justified. **§211.160(b) — Laboratory controls shall include:** - **(1)** Determination of conformance to applicable written specifications for the acceptance of each lot within each shipment of components, drug product containers, closures, and labeling used in the manufacture, processing, packing, or holding of drug products. - **(2)** Determination of conformance to written specifications and a description of sampling and testing procedures and, where appropriate, methodological limitations for in-process materials and drug products. The sampling and testing procedures shall include the kind and number of tests; such procedures shall assure that batches of drug products meet specifications. - **(3)** The establishment of the accuracy, sensitivity, specificity, and reproducibility of test methods used. Such validation and documentation may be accomplished in accordance with §211.194(a)(2). - **(4)** The calibration of instruments, apparatus, gauges, and recording devices at suitable intervals in accordance with an established written program containing specific directions, schedules, limits for accuracy and precision, and provisions for remedial action in the event accuracy and/or precision limits are not met. Instruments, apparatus, gauges, and recording devices not meeting established specifications shall not be used. **§211.165 — Testing and release for distribution:** **(a)** For each batch of drug product, there shall be appropriate laboratory determination of satisfactory conformance to final specifications for the drug product, including the identity and strength of each active ingredient, prior to release. Where sterility and/or pyrogen testing are conducted on specific batches of short-lived radiopharmaceuticals, such batches may be released prior to completion of sterility and/or pyrogen testing, pending the results of such testing. **(b)** There shall be appropriate laboratory testing, as necessary, of each batch of drug product required to be free of objectionable microorganisms. **(c)** Any sampling and testing plans shall be described in written procedures that shall include the method of sampling and the number of units per batch to be tested; such written procedure shall be followed. **(d)** Acceptance criteria for the sampling and testing conducted by the quality control unit shall be adequate to assure that batches of drug products meet each appropriate specification and appropriate statistical quality control criteria as a condition for their approval and release. The statistical quality control criteria shall include appropriate acceptance levels and/or rejection levels. **(e)** The accuracy, sensitivity, specificity, and reproducibility of test methods employed by the firm shall be established and documented. Such validation and documentation may be accomplished in accordance with §211.194(a)(2). Appropriate controls shall be used to validate results of each test method. **(f)** Drug products failing to meet established standards or specifications and any other relevant quality criteria shall be rejected. Reprocessing may be performed. Prior to acceptance and use, reprocessed material must meet appropriate standards, specifications, and any other relevant criteria. "The requirements in this subpart shall be followed and shall be documented at the time of performance. Any deviation from the written specifications… shall be recorded and justified." *— 21 CFR §211.160(a)* --- ### Document: FDA 21CFR 820 Complete (FDA) # 21 CFR Part 820 — Quality Management System Regulation (QMSR): FDA Quality System Requirements for Medical Device Manufacturers — 2024 QMSR Final Rule Aligned with ISO 13485:2016 ## Section 0: Overview — QMSR Transition & 2024 Final Rule (§820.1 + FDA Final Rule Preamble) # Section 0: Overview — QMSR Transition & 2024 Final Rule 21 CFR Part 820 — Quality Management System Regulation (QMSR) | FDA | eCFR current (effective Feb 2, 2026) **Background — FDA Quality System Regulation Amendments (Final Rule, Feb 2, 2024):** "FDA is amending the device current good manufacturing practice (CGMP) requirements of the Quality System Regulation (QSR), which are codified in 21 CFR part 820. The agency is revising part 820 to incorporate by reference the international consensus standard ISO 13485:2016, Medical devices – Quality management systems – Requirements for regulatory purposes. FDA also is making other revisions to part 820 to align with the incorporated standard. This final rule renames part 820 the Quality Management System Regulation (QMSR)." *— 89 FR 7496, Feb 2, 2024 (Docket No. FDA-2019-N-1947)* **Historical Background — QSR (Quality System Regulation, 1996):** The original QSR took effect on June 1, 1997. It was FDA's first comprehensive quality system standard for medical device manufacturers and was modeled on ISO 9001 (1987 version). Over the following decades, ISO 13485 emerged as the global benchmark — adopted by the EU (IVDR/MDR), Canada (CMDCAS), Japan (JPAL), and most competent authorities worldwide. This created a dual-compliance burden: U.S. manufacturers had to maintain both an FDA QSR system AND an ISO 13485 QMS simultaneously. **21 CFR § 820.1 — Scope (QMSR, effective Feb 2, 2026):** "(a) The requirements in this part govern the methods used in, and the facilities and controls used for, the design, manufacture, packaging, labeling, storage, installation, and servicing of all finished devices intended for human use. The requirements in this part are intended to ensure that finished devices will be safe and effective and otherwise in compliance with the Federal Food, Drug, and Cosmetic Act (the act). This part establishes basic requirements applicable to manufacturers of finished devices. If a manufacturer engages in only some operations subject to the requirements in this part, and not in others, that manufacturer need only comply with those requirements applicable to the operations in which it is engaged." *— 21 CFR § 820.1(a) (paraphrased from QMSR final rule; verify against current eCFR)* "(b) FDA does not intend this part to apply to manufacturers of components or parts of finished devices, but such manufacturers are encouraged to use appropriate provisions of this regulation as guidance." --- **Why FDA Changed the Rule — Stated Rationale:** - **Global harmonization:** Align U.S. requirements with international standard already adopted by most competent authorities. - **Reduce duplicative burden:** Manufacturers certified to ISO 13485 will have substantially overlapping QMS documentation; QMSR eliminates the need to maintain two parallel systems. - **Leverage modern quality concepts:** ISO 13485:2016 incorporates risk-based thinking, lifecycle management, and software-specific provisions absent from the 1996 QSR. - **FDA enforcement alignment:** FDA can inspect against ISO 13485 clauses, providing a common framework recognized by inspectors globally (MDSAP). "By incorporating ISO 13485 by reference, FDA is able to leverage the work of a consensus standards organization and provide requirements that are consistent with an internationally recognized QMS standard. This will reduce the compliance burden for manufacturers that maintain a quality management system consistent with ISO 13485." *— FDA preamble, 89 FR 7496 (Feb 2, 2024)* ## Section 1: §820.1–820.3 — Scope, Applicability & Definitions (§§ 820.1–820.3) # Section 1: §820.1–820.3 — Scope, Applicability & Definitions 21 CFR Part 820 — QMSR | FDA | §§ 820.1–820.3 | eCFR current as of April 2026 **§820.1(a) — General** **(1)** Current good manufacturing practice (CGMP) requirements are set forth in this quality system regulation. The requirements in this part govern the methods used in, and the facilities and controls used for, the design, manufacture, packaging, labeling, storage, installation, and servicing of all finished devices intended for human use. The requirements in this part are intended to ensure that finished devices will be safe and effective and otherwise in compliance with the Federal Food, Drug, and Cosmetic Act (the act). This part establishes basic requirements applicable to manufacturers of finished medical devices. **(2)** If a manufacturer engages in only some operations subject to the requirements in this part, and not in others, that manufacturer need only comply with those requirements applicable to the operations in which it is engaged. **(3)** With respect to class I devices, design controls apply only to those devices listed in §820.30(a)(2). This regulation does not apply to manufacturers of components or parts of finished devices, but such manufacturers are encouraged to use appropriate provisions of this regulation as guidance. Manufacturers of human blood and blood components are not subject to this part, but are subject to part 606 of this chapter. **§820.1(b) — Responsibility of manufacturers** Each manufacturer shall be responsible for establishing and maintaining an adequate quality system with the organizational structure, responsibilities, procedures, processes, and adequate resources for assuring that devices will be safe and effective and otherwise in compliance with this part. **§820.1(c) — Applicability** The quality system regulation applies to any finished device manufacturer who imports, exports, repackages, or relabels a device. A manufacturer of a finished medical device must comply with this part regardless of where the device is manufactured. **§820.1(d) — Foreign manufacturers** If a manufacturer who offers devices for import into the United States refuses to permit or allow the completion of a Food and Drug Administration inspection of the foreign facility for the purpose of determining compliance with this part, it shall appear for purposes of section 801(a) of the act, that the methods used in, and the facilities and controls used for, the design, manufacture, packaging, labeling, storage, installation, or servicing of any devices produced at such facility that are offered for import into the United States do not conform to the requirements of section 520(f) of the act and this part and that the devices manufactured at that facility are adulterated. **§820.1(e) — Exemptions or variances** Any person who wishes to petition for an exemption or variance from any device quality system requirement is subject to the requirements of section 520(f)(2) of the act. Petitions for an exemption or variance shall be submitted according to the procedures set forth in §10.30 of this chapter, the FDA's administrative procedures. Guidance documents on the exemption procedures are available from CDRH. "Each manufacturer shall be responsible for establishing and maintaining an adequate quality system…for assuring that devices will be safe and effective." *— 21 CFR §820.1(b)* ## Section 2: §820.4 — QMS Requirements & ISO 13485 Integration (§820.4 + ISO 13485:2016 §§4–6) # Section 2: §820.4 — QMS Requirements & ISO 13485 Integration 21 CFR Part 820 — QMSR | FDA | §820.4 + ISO 13485:2016 §§4–6 ## Subsection 1 — §820.4: QMS Requirements (Regulatory Text) #### §820.4 — Quality Management System Requirements *Text effective February 2, 2026 (21 CFR Part 820 QMSR Final Rule)* Each manufacturer subject to this part must establish, implement, and maintain a quality management system that meets the requirements of ISO 13485:2016, *Medical devices — Quality management systems — Requirements for regulatory purposes*, incorporated by reference in §820.1(b), as supplemented by the requirements in Appendix A of this part. ### What "Incorporated by Reference" Means Legally Under the Administrative Procedure Act (5 U.S.C. 552(a)) and 1 CFR Part 51, when FDA incorporates a document by reference into the Code of Federal Regulations, that document carries the full legal force of federal regulation. Compliance with ISO 13485:2016 is therefore not voluntary guidance — it is a federal legal requirement for all manufacturers subject to 21 CFR Part 820. The Office of the Federal Register publishes availability notices when standards are incorporated. Manufacturers must use the specific version cited in §820.1(b) — ISO 13485:2016 — regardless of whether newer versions of the standard are released. ### Scope of Application §820.4 applies to manufacturers of finished devices intended for commercial distribution in the United States. The term "manufacturer" is defined in §820.3 and includes any person who designs, manufactures, fabricates, assembles, or processes a finished device. Contract manufacturers (CDMOs), specification developers, and repackagers are all potentially subject depending on their role. ### Structure: ISO 13485 + Appendix A The QMSR operates as a two-layer framework: - **Layer 1 — ISO 13485:2016:** The baseline QMS standard providing all general requirements for documentation, management responsibility, resources, product realization, and measurement/analysis/improvement. - **Layer 2 — Appendix A:** FDA-specific supplemental requirements that either modify ISO 13485 provisions or add requirements that have no ISO 13485 equivalent. Where Appendix A and ISO 13485 differ, Appendix A controls. ## — §820.4 #### QMSR #### Incorporation by Reference #### + #### ISO 13485 ## Subsection 2 — ISO 13485:2016 Sections 4, 5, and 6 ### Section 4 — Quality Management System **4.1 General Requirements:** The organization shall establish, document, implement, and maintain a QMS and maintain its effectiveness in accordance with the requirements of the standard. The organization shall document its QMS in a manner that ensures the ability of devices and services to meet requirements and to facilitate improvement of the QMS. **4.2 Documentation Requirements:** - **4.2.1 General:** QMS documentation shall include a documented quality policy and quality objectives; a quality manual; documented procedures required by the standard; documents needed to ensure the effective planning, operation, and control of processes; records required by the standard; and any other documentation specified by applicable regulatory requirements. - **4.2.2 Quality Manual:** Must include the scope of the QMS with justification for any exclusions; documented procedures or references to them; a description of the interaction between QMS processes; and a description of the structure of the documentation used in the QMS. - **4.2.3 Medical Device File (Technical File/DHF):** Each device or family of devices must have a dedicated medical device file that includes documents providing a description of the device, its intended use, labeling, and specifications; procedures and records relevant to the device including design and development, production, testing, and post-market activities. - **4.2.4 Control of Documents:** Procedures for approving documents for adequacy, reviewing/updating and re-approving, identifying changes and revision status, ensuring current versions at point of use, ensuring readability, identifying external documents, and preventing unintended use of obsolete documents. - **4.2.5 Control of Records:** Records established to provide evidence of conformity and effective operation of the QMS shall be controlled. Retention period must be at least equivalent to the lifetime of the device as defined by the manufacturer, but not less than 2 years from the date of product release by the manufacturer, or as specified by applicable regulatory requirements. ### Section 5 — Management Responsibility **5.1 Management Commitment:** Top management shall provide evidence of its commitment to development and implementation of the QMS and maintaining its effectiveness by communicating regulatory requirements, establishing quality policy and objectives, conducting management reviews, and ensuring availability of resources. **5.3 Quality Policy:** Top management shall ensure the quality policy is appropriate to the organization's purpose; includes a commitment to comply with requirements and to maintain the effectiveness of the QMS; provides a framework for quality objectives; is communicated and understood at appropriate levels; and is reviewed for continuing suitability. **5.4 Planning:** 5.4.1 Quality objectives must be established at relevant functions and levels, be measurable, consistent with the quality policy, and include those needed to meet product requirements. 5.4.2 Quality management system planning must maintain the integrity of the QMS when changes are planned and implemented. **5.5 Responsibility, Authority, and Communication:** Top management shall define and communicate responsibilities and authorities. A management representative must be appointed with authority and responsibility for ensuring QMS processes are established and maintained, reporting on QMS performance, and promoting awareness of applicable regulatory requirements and QMS requirements throughout the organization. **5.6 Management Review:** Top management shall review the QMS at planned intervals to ensure its continuing suitability, adequacy, and effectiveness. Records of management reviews shall be maintained. Management review **inputs** must include: feedback, complaint handling, reporting to regulatory authorities, audit results, monitoring and measurement of processes and products, corrective and preventive actions, follow-up actions from previous reviews, changes that could affect the QMS, and recommendations for improvement. Management review **outputs** must include decisions and actions related to: improvement needed to maintain the suitability, adequacy, and effectiveness of the QMS; improvement of product related to customer requirements; and resource needs. ### Section 6 — Resource Management **6.1 Provision of Resources:** The organization shall determine and provide the resources needed to implement and maintain the QMS, maintain its effectiveness, and meet applicable regulatory requirements and customer requirements. **6.2 Human Resources:** Personnel performing work affecting product quality shall be competent based on appropriate education, training, skills, and experience. The organization shall determine the necessary competence, provide training or take other actions to achieve necessary competence, evaluate the effectiveness of actions taken, ensure personnel are aware of the relevance and importance of their activities, and maintain appropriate records of education, training, skills, and experience. **6.3 Infrastructure:** The organization shall determine, provide, and maintain infrastructure needed to achieve product conformity. Infrastructure includes buildings, workspace, and associated utilities; process equipment (hardware and software); and supporting services such as information systems. **6.4 Work Environment and Contamination Control:** The organization shall determine and manage the work environment needed to achieve conformity to product requirements. Requirements include documented requirements for health, cleanliness, clothing of personnel if contact with product or work environment could adversely affect product quality. Arrangements for controlling contaminated or potentially contaminated products shall be documented to prevent contamination of other products, the work environment, or personnel. ## — ISO 13485 §4–6 #### ISO 13485 §4–6 QMS #### §4.2 #### vs —— | | (Controlled Document) | (Record) | | --- | --- | --- | | | / | | | | SOPWI | CAPA | #### #### §6.2 #### §6.4 —— ## Subsection 3 — Document Control & Record Retention Requirements ### ISO 13485 §4.2.4 — Control of Documents A documented procedure shall be established to define the controls needed for: - Approving documents for adequacy prior to issue - Reviewing and updating as necessary and re-approving documents - Ensuring that changes and the current revision status of documents are identified - Ensuring that relevant versions of applicable documents are available at points of use - Ensuring that documents remain legible and readily identifiable - Ensuring that documents of external origin are identified and their distribution controlled - Preventing the unintended use of obsolete documents, and applying suitable identification to them if they are retained for any purpose The organization shall prevent the deterioration or loss of documents. Changes to documents shall be reviewed and approved either by the original approving function or another designated function that has access to pertinent background information upon which to base its decisions. ### ISO 13485 §4.2.5 — Control of Records Records shall be established and maintained to provide evidence of conformity to requirements and of the effective operation of the QMS. Records shall remain legible, readily identifiable, and retrievable. A documented procedure shall be established to define the controls needed for: - Identification of records - Storage and protection of records - Retrieval of records - Retention time of records - Disposition of records The organization shall retain records for at least the period equivalent to the lifetime of the medical device as defined by the organization, but not less than 2 years from the date of product release by the manufacturer, or as otherwise specified by applicable regulatory requirements. ### FDA Retention Requirement (Appendix A / QMSR) FDA's record retention requirement for device history records (DHRs), device master records (DMRs), and quality system records is more specific than ISO 13485's baseline. Under the QMSR, records must be retained for a period equivalent to the design and expected life of the device, but in no case less than 2 years from the date of release of the device for commercial distribution by the manufacturer. The practical calculation: identify the expected lifetime of the device (e.g., a reusable surgical instrument with 10-year expected service life), add 2 years, and that is the minimum retention period. For many implantable devices with long service lives (cardiac pacemakers, orthopedic implants), this calculation can extend retention requirements to 15–25+ years. ## — #### §4.2.4 #### ``` ``` #### Distribution Control #### FDA 483 —— ## Subsection 4 — FDA Appendix A: FDA-Specific Additions and Modifications Appendix A to 21 CFR Part 820 contains FDA-specific requirements that supplement ISO 13485:2016. These fall into two categories: (1) requirements that modify or clarify how ISO 13485 provisions apply in the US context, and (2) requirements with no ISO 13485 equivalent that reflect longstanding FDA regulatory priorities. ### Design Controls — Mandatory Under FDA, Optional Under ISO 13485 ISO 13485:2016 §7.3 permits manufacturers to exclude design and development requirements if the design and development of medical devices is performed by an outside party or if the design is well established and documented. This exclusion is permissible under the international standard for manufacturers that only produce to customer-owned designs. FDA's Appendix A removes this option for manufacturers subject to §820.4. Design controls are mandatory for all manufacturers of Class II and Class III devices, and for Class I devices with design specifications. A specification developer or US agent who holds the device master record cannot claim ISO 13485 §7.3 exclusion under QMSR. This is one of the most significant FDA additions. ### Complaint Handling — Cross-Reference to §820.198 While ISO 13485 §8.2.2 addresses feedback and §8.5.1 addresses complaint handling in general terms, FDA Appendix A requires compliance with the specific requirements of §820.198, which mandates: - A formally designated unit responsible for receiving, reviewing, and evaluating complaints - Written procedures for complaint handling - Evaluation of every complaint to determine whether a MDR report is required under 21 CFR Part 803 - Complaint records to be kept at the manufacturing establishment - Specific content requirements for complaint records including the device name, lot/control number, date received, name/address of complainant, nature of complaint, and investigation results ### MDR (Medical Device Reporting) Cross-References Appendix A establishes explicit cross-references between QMSR quality system activities and the MDR reporting obligations under 21 CFR Part 803. The QMS must include procedures that identify when events associated with marketed devices constitute reportable events, and that ensure timely reporting within the applicable MDR timeframes (30-day for non-malfunction serious injury/death; 5-day for MDR-reportable events requiring immediate action). ### Language Requirements For devices distributed in the United States, records, labeling, and submissions required under QMSR must be in the English language or have English translations available. This supplements ISO 13485, which does not specify a language requirement. A company whose operational language is not English must ensure English-language versions of device history records, complaint files, and quality records are accessible to FDA investigators during inspections. ### Correction and Removal Reporting — Cross-Reference to 21 CFR Part 806 Appendix A establishes that CAPA activities under ISO 13485 §8.5.2 and §8.5.3 must interface with field correction and removal reporting obligations under 21 CFR Part 806. Where a CAPA involves a device already distributed, the QMS must trigger evaluation of whether a §806 report is required. ## — Appendix A FDA #### ISO 13485 #### CDMO #### §820.198 —— #### Appendix A FDA ## Subsection 5 — Comparison: ISO 13485 §5/§6 vs. Old QSR §820.20 The original QSR (1996/2002 Quality System Regulation) had a self-contained §820.20 addressing management responsibility. The QMSR replaces those provisions by incorporating ISO 13485 §5 and §6. The table below maps old §820.20 provisions to their QMSR equivalents. | Old QSR §820.20 Provision | QMSR / ISO 13485:2016 Equivalent | Change Summary | | --- | --- | --- | **** | §820.20(a) — Quality policy: Top management shall establish a quality policy | ISO 13485 §5.1 + §5.3 | Substantially similar; ISO 13485 adds requirement that quality policy provide a framework for quality objectives | **** | §820.20(b)(1) — Organizational structure: Organizational chart and responsibility/authority | ISO 13485 §5.5.1 | Essentially identical; ISO 13485 uses "defined and communicated" language | **** | §820.20(b)(2) — Management representative with authority over QS | ISO 13485 §5.5.2 | ISO 13485 adds explicit requirement to promote awareness of applicable regulatory requirements | **** | §820.20(b)(3) — Adequate resources (personnel, equipment) | ISO 13485 §6.1 + §6.2 + §6.3 | ISO 13485 significantly expands this — adds competence assessment, training effectiveness evaluation, infrastructure maintenance, work environment management | **** | §820.20(c) — Management review at defined intervals with defined records | ISO 13485 §5.6 | ISO 13485 specifies mandatory inputs and outputs; old QSR was less prescriptive on content | **** | §820.20(d) — Quality planning: quality plans, quality objectives | ISO 13485 §5.4 | Essentially equivalent; ISO 13485 adds requirement for QMS planning to maintain integrity during changes | **** | §820.20(e) — Quality system procedures established and maintained | ISO 13485 §4.1 + §4.2 | ISO 13485 adds Medical Device File requirement (§4.2.3) and is more explicit about documentation hierarchy | ** | No equivalent in old QSR §820.20 | ISO 13485 §6.4 — Work environment and contamination control | New explicit requirement for documenting work environment requirements and contamination control arrangements | ### What Stayed the Same The fundamental obligations of management responsibility did not change materially: top management must be engaged, there must be a management representative, resources must be adequate, management reviews must occur, and quality policies and objectives must be established. The QMSR adopted these existing requirements wholesale via ISO 13485. ### What Changed — Key Additions - **More prescriptive management review:** ISO 13485 §5.6 specifies exactly what inputs must be reviewed and what outputs must be produced — more rigorous than old §820.20(c) - **Competence evaluation:** Old §820.20 required "adequate" personnel; ISO 13485 §6.2 requires formal competence determination, training, effectiveness evaluation, and records - **Work environment:** Old QSR addressed this in §820.70(c); ISO 13485 §6.4 consolidates it under resource management - **Medical Device File:** New concept under ISO 13485 §4.2.3 — each device or device family must have a dedicated file aggregating all relevant QMS documents and records ## — #### QSR #### / #### ISO 13485 §4.2.3 Medical Device File—— ## Application Scenario — CDMO ISO 13485 to QMSR Gap Analysis #### Scenario: Contract Sterile Device CDMO — ISO 13485 Certified, Entering US Market **Background:** SterileMed Manufacturing (hypothetical) is a contract manufacturer based in Singapore. It holds ISO 13485:2016 certification from a Notified Body. Its client base includes EU and Japanese OEMs. It has been approached by a US Class II device company to manufacture their sterile single-use laparoscopic instruments under a Supply Agreement. This will be the CDMO's first US-distributed product. **QMSR Compliance Gap Analysis — Actions Required:** **1. Design Controls Assessment** SterileMed's ISO 13485 certification excludes §7.3 because all device designs are customer-supplied. Under QMSR Appendix A, this exclusion is not permitted. Action required: determine the scope of design responsibility. If SterileMed only manufactures to customer-locked specifications without modification, it may argue it is not performing design and development under the QMSR definition. However, if it specifies any manufacturing process parameters that affect design outputs, it must establish design controls. Recommend: negotiate a Design Control Matrix with the US client defining where each party's responsibility begins and ends; document this in the Quality Agreement. **2. Complaint Handling Upgrade to §820.198** SterileMed's existing complaint procedure meets ISO 13485 §8.2.2 but lacks: (a) a formal unit designated for US complaint handling; (b) a documented MDR evaluation step for each US complaint; (c) specific record content fields required by §820.198. Action required: revise complaint procedure to add MDR evaluation logic tree, define responsible US-designated unit (can be the client company under Quality Agreement), align complaint record format with §820.198 requirements. **3. English Language Records** SterileMed's quality records are maintained in English and Mandarin Chinese. For FDA inspection purposes, English versions must be the primary accessible versions. Action required: confirm all Device History Records, CAPA records, complaint files, and management review records are available in English; ensure FDA investigators have access during US inspections. **4. MDR Cross-Reference in QMS Procedures** No existing procedure connects ISO 13485 §8.5 CAPA activities to US MDR reporting timelines. Action required: add a procedure step (or new procedure) that routes US complaint-related CAPAs through a 21 CFR Part 803 evaluation; establish 30-day and 5-day MDR clocks in the QMS. **5. Record Retention Adjustment** SterileMed currently retains records for device lifetime + 2 years per ISO 13485. For the US product (single-use instruments, 3-year shelf life), FDA formula yields: 3 years (device lifetime) + 2 years = minimum 5 years from release. Current retention policy likely already meets this. Action required: verify retention calculation for each product type; if any product has a device lifetime exceeding current ISO-driven retention periods, update retention schedule. ## — CDMO #### ISO 13485 QMSR #### Quality Agreement CDMO #### FDA ——§820.4 ## Section Summary — Key Takeaways #### Core Points — §820.4 and ISO 13485 Integration - **§820.4 is brief but comprehensive:** Manufacturers must meet ISO 13485:2016 (incorporated by reference with legal force) plus FDA Appendix A supplements. The entire QMSR regulatory framework flows from this single provision. - **ISO 13485 §4 (Documentation):** Four-tier document hierarchy; controlled documents require version management, approval, and distribution control; records require retention for device lifetime + 2 years minimum under FDA rules. - **ISO 13485 §5 (Management):** Top management accountability is formalized — quality policy, objectives, management representative, and especially management review with prescribed inputs and outputs. This is substantially more prescriptive than the old QSR. - **ISO 13485 §6 (Resources):** Competence-based training with effectiveness evaluation; infrastructure maintenance; work environment and contamination control documentation. - **Appendix A FDA additions:** Design controls cannot be excluded; complaint handling must meet §820.198 detail level including MDR evaluation; MDR and Part 806 cross-references must be built into QMS procedures; English language records must be available. - **Document vs. Record distinction:** Documents guide future action (mutable, version-controlled); records evidence past action (immutable, retention-controlled). Treating records as documents or vice versa is a common 483 finding. ## #### §820.4 + ISO 13485 #### ## Section 3: Design Controls & Product Realization (FDA Additions) (ISO 13485:2016 §7 + FDA Appendix A additions) # Section 3: Design Controls & Product Realization (FDA Additions) 21 CFR Part 820 — QMSR | FDA | ISO 13485:2016 §7 + FDA Appendix A additions ## Regulatory Text **ISO 13485:2016 §7.3.1 — Design and Development General** The organization shall document procedures for design and development. *Note: Design and development controls may be excluded when justified. See §4.2.2.* **21 CFR Part 820 Appendix A (QMSR FDA-Specific Requirements) — Design Controls** Notwithstanding any exclusion permitted under ISO 13485:2016 §7.3, manufacturers of finished devices subject to this part that are Class II or Class III devices, or Class I devices listed in §820.30(a)(2), shall establish and maintain procedures to control the design of the device in order to ensure that specified design requirements are met. **§820.30(a) — Design and development planning (legacy text, now codified via ISO §7.3.2)** (1) Each manufacturer of any class III or class II device, and the class I devices listed in paragraph (a)(2) of this section, shall establish and maintain procedures to control the design of the device in order to ensure that specified design requirements are met. **§820.30(b) — Design and development planning** Each manufacturer shall establish and maintain plans that describe or reference the design and development activities and define responsibility for implementation. The plans shall identify and describe the interfaces with different groups or activities that provide, or result in, input to the design and development process. The plans shall be reviewed, updated, and approved as design and development evolves. **§820.30(c) — Design inputs** Each manufacturer shall establish and maintain procedures to ensure that the design requirements relating to a device are appropriate and address the intended use of the device, including the needs of the user and patient. The procedures shall include a mechanism for addressing incomplete, ambiguous, or conflicting requirements. The design input requirements shall be documented and shall be reviewed and approved by a designated individual(s). **§820.30(d) — Design outputs** Each manufacturer shall establish and maintain procedures for defining and documenting design output in terms that allow an adequate evaluation of conformance to design input requirements. Design output procedures shall contain or make reference to acceptance criteria and shall ensure that those design outputs that are essential for the proper functioning of the device are identified. Design output shall be documented, reviewed, and approved before release. **§820.30(e) — Design review** Each manufacturer shall establish and maintain procedures to ensure that formal documented reviews of the design results are planned and conducted at appropriate stages of the device's design development. The procedures shall ensure that participants at each design review include representatives of all functions concerned with the design stage being reviewed, as well as an individual(s) who does not have direct responsibility for the design stage being reviewed, when practicable. The results of a design review, including identification of the design, the date, and the individual(s) performing the review, shall be documented in the DHF. **§820.30(f) — Design verification** Each manufacturer shall establish and maintain procedures for verifying the device design. Design verification shall confirm that the design output meets the design input requirements. The results of the design verification, including identification of the design, method(s), the date, and the individual(s) performing the verification, shall be documented in the DHF. **§820.30(g) — Design validation** Each manufacturer shall establish and maintain procedures for validating the device design. Design validation shall be performed under defined operating conditions on initial production units, lots, or batches, or their equivalents. Design validation shall ensure that devices conform to defined user needs and intended uses and shall include testing of production units under actual or simulated use conditions. Design validation shall include software validation and risk analysis, where appropriate. The results of the design validation, including identification of the design, method(s), the date, and the individual(s) performing the validation, shall be documented in the DHF. **§820.30(h) — Design transfer** Each manufacturer shall establish and maintain procedures to ensure that the device design is correctly translated into production specifications. These specifications shall be part of the device master record. Where a device design is transferred to an outside manufacturer, the receiving manufacturer must have access to the relevant design history file. **§820.30(i) — Design changes** Each manufacturer shall establish and maintain procedures for the identification, documentation, validation or where appropriate verification, review, and approval of design changes before their implementation. **§820.30(j) — Design History File (DHF)** Each manufacturer shall establish and maintain a DHF for each type of device. The DHF shall contain or reference the records necessary to demonstrate that the design was developed in accordance with the approved design plan and the requirements of this part. "Design validation shall be performed under defined operating conditions on initial production units… and shall include testing of production units under actual or simulated use conditions." *— 21 CFR §820.30(g), now incorporated via ISO 13485:2016 §7.3.7 + FDA Appendix A* ## Section 4: CAPA, Nonconforming Product, Complaint Files & Records (ISO 13485:2016 §8 + §820.198 + MDR cross-references) # Section 4: CAPA, Nonconforming Product, Complaint Files & Records 21 CFR Part 820 — QMSR | FDA | ISO 13485:2016 §8 + §820.198 + MDR cross-references **Regulatory Basis:** ISO 13485:2016 §8.3 / 21 CFR Part 820 QMSR incorporates ISO 13485 by reference. The organization shall ensure that product which does not conform to product requirements is identified and controlled to prevent its unintended use or delivery. **Core Requirements:** - **Identification:** Nonconforming product must be clearly identified — labeling, tags, physical segregation, system flags in electronic batch records. - **Segregation:** Physical or system-based quarantine from conforming product. Separate holding areas with controlled access. The purpose is unambiguous — prevent mix-up, prevent inadvertent release. - **Documentation:** Written records describing the nonconformity, the product involved, quantities, dates discovered, and the disposition decision with rationale. **Disposition Decisions (§8.3.3):** - **Rework:** Processing to bring product into conformance with specification. Requires written rework procedure, re-testing per the original acceptance criteria, and documentation that rework was performed. Rework must be evaluated for adverse effect on product. - **Scrap / Destruction:** Final disposition for product that cannot be reworked or accepted. Destruction must be documented — quantity, method, personnel, date. - **Use-as-Is (Deviation/Concession):** Acceptance of nonconforming product under a documented concession. Requires risk-based justification demonstrating the nonconformity does not affect safety, effectiveness, or essential performance. Customer or regulatory notification may be required. Cannot be used for safety-critical nonconformities. - **Return to Supplier:** For incoming material nonconformities — documented return with supplier notification and quarantine until resolution. **Re-verification After Rework (§8.3.4):** Product that has been reworked shall be re-inspected or re-tested against original acceptance criteria. The re-inspection results shall be documented in the DHR (Device History Record). **Advisory Notice Considerations:** If a nonconformity is discovered in distributed (released) product, the organization must evaluate: - Does it constitute a malfunction that could cause or contribute to serious injury if it recurs? MDR evaluation required (21 CFR Part 803) - Does the nonconformity affect a significant number of devices? Field Correction / Recall consideration (21 CFR Part 806) - Is an Advisory Notice to users required (ISO 13485 §8.3.4)? **Linkage to CAPA:** A single nonconformity event may be handled as a deviation. However, if trend analysis reveals a pattern (same nonconformity type recurring), this must trigger a CAPA to address the systemic root cause. ISO 13485 §8.3 §8.5.2 linkage is mandatory and must be documented. --- ### Document: FDA 21CFR Biologics Complete (FDA) # 21 CFR Subchapter F — Biologics (Parts 600–680): FDA Regulatory Framework for Biological Products: Licensing, Manufacturing Standards, and Lot Release Requirements 21 CFR SUBCHAPTER F — BIOLOGICS (PARTS 600–680) Title 21, Code of Federal Regulations Center for Biologics Evaluation and Research (CBER), FDA Source: eCFR / Cornell LII / GovInfo — current as of April 2026 OVERVIEW AND SCOPE 21 CFR Subchapter F (Parts 600–680) is FDA's regulatory framework for biological products throughout their lifecycle — from licensing through manufacturing, testing, and postmarket reporting. This applies to vaccines, blood products, plasma-derived therapies, allergenic substances, and certain diagnostic materials. Biological products regulated under section 351 of the Public Health Service Act (PHS Act) must also comply with applicable provisions of 21 CFR Parts 210 and 211 (drug CGMPs). Parts in Subchapter F: - Part 600: Biological Products: General (establishment controls, deviation management, postmarket responsibilities) - Part 601: Licensing (BLA applications, supplements, controlled change management) - Part 610: General Biological Products Standards (safety, purity, potency, identity, labeling, lot release) - Part 606: Current Good Manufacturing Practice for Blood and Blood Components - Part 607: Establishment Registration and Product Listing for Blood Products - Part 630: Requirements for Blood and Blood Products (donor eligibility) - Part 640: Additional Standards for Blood and Blood Components (labeling, storage, identity) - Part 660: Additional Standards for Diagnostic Substances for Laboratory Tests - Part 680: Additional Standards for Miscellaneous Products (allergenics) PART 600 — BIOLOGICAL PRODUCTS: GENERAL Subpart A — General Provisions Section 600.2 Mailing Addresses All submissions referenced in Parts 600–680 must be sent to the Director of the Center for Biologics Evaluation and Research (CBER) or Center for Drug Evaluation and Research (CDER), depending on product type. Section 600.3 Definitions Key definitions used throughout Subchapter F: (a) Act — The Public Health Service Act (58 Stat. 682), approved July 1, 1944. (b) Secretary — The Secretary of Health and Human Services and delegated officers/employees. (c) Commissioner of Food and Drugs — The FDA Commissioner. (d) Center for Biologics Evaluation and Research — FDA's CBER division. (e) State — A State, District of Columbia, Puerto Rico, or Virgin Islands. (f) Possession — Includes Puerto Rico and Virgin Islands. (g) Products — Encompasses biological products and trivalent organic arsenicals. (h) Biological product — "A virus, therapeutic serum, toxin, antitoxin, vaccine, blood, blood component or derivative, allergenic product, protein, or analogous product, or arsphenamine or derivative of arsphenamine (or any other trivalent organic arsenic compound), applicable to the prevention, treatment, or cure of a disease or condition of human beings." A protein is any alpha amino acid polymer with a specific, defined sequence greater than 40 amino acids in size. (i) Trivalent organic arsenicals — Arsphenamine derivatives applicable to disease prevention/treatment in humans. (j) Applicable to prevention/treatment/cure — Includes diagnostic use via administration or application. (k) Proper name — The licensed product designation on packaging. (l) Dating period — Period where product can reasonably yield specific results. (m) Expiration date — Calendar date/time marking the dating period's end. (n) Standards — Specifications and procedures for establishments or manufacturing. (o) Continued — Applied to product safety, purity, potency during dating period. (p) Safety — "The relative freedom from harmful effect to persons...when prudently administered..." (q) Sterility — Freedom from viable contaminating microorganisms (per § 610.12). (r) Purity — Relative freedom from extraneous matter, moisture, volatile/pyrogenic substances. (s) Potency — "The specific ability or capacity of the product...to effect a given result." (t) Manufacturer — Legal entities engaged in licensed product manufacture or license applicants assuming compliance responsibility. (u) Manufacture — Steps in product propagation including "filling, testing, labeling, packaging, and storage." (v) Location — Buildings, equipment, animals, and personnel within manufacturer's designated area. (w) Establishment — Same meaning as "facility" per Public Health Service Act § 351. (x) Lot — "That quantity of uniform material identified by the manufacturer as having been thoroughly mixed in a single vessel." (y) Filling — Final containers identical and filled from same bulk lot without integrity-affecting changes. (z) Process — Manufacturing steps affecting product safety, purity, or potency. (aa) Selling agent or distributor — Persons distributing licensed products other than retail. (bb) Container — "The immediate unit, bottle, vial, ampule, tube, or other receptacle containing the product." (cc) Package — Immediate carton, wrapper, and labeling with enclosed container contents. (dd) Label — "Any written, printed, or graphic matter on the container or package." (ee) Radioactive biological product — Products labeled with or intended for radionuclide labeling. (ff) Amendment — Submission revising/modifying pending license applications. (gg) Supplement — Request approving changes in approved license applications. (hh) Distributed — Biological product leaving manufacturer's control. (ii) Control — Responsibility for maintaining continued product safety, purity, potency, and regulatory compliance. (jj) Assess the effects of the change — Evaluating manufacturing changes on product identity, strength, quality, purity, and potency. (kk) Specification — "The quality standard (i.e., tests, analytical procedures, and acceptance criteria)." (ll) Complete response letter — FDA communication describing deficiencies in license applications. (mm) Resubmission — Applicant submission addressing all complete response letter deficiencies. Subpart B — Establishment Standards Section 600.10 Personnel Personnel must possess "capabilities commensurate with their assigned functions, a thorough understanding of the manufacturing operations" they perform, and receive proper training. Facilities must include professionally trained persons necessary for competent performance of all manufacturing processes. Restriction categories: (b) Personnel qualifications — Training and experience requirements for all manufacturing staff. (c)(1) Product safety — Individuals whose presence could "affect adversely the safety and purity of a product" face exclusion from manufacturing areas during active production. (c)(2) Sterile operations — Those performing sterile work must don "clean or sterilized protective clothing and devices" sufficient to prevent product contamination. (c)(3) Pathogenic work — Personnel handling human pathogens or spore-forming microorganisms, or caring for animals, must either be excluded from other manufacturing areas or change outer garments and footwear before entering such spaces. (c)(4) Live vaccine areas — The strictest rules apply here. Personnel cannot enter live vaccine areas after working with other infectious agents the same day. Only essential personnel are permitted during active work. Street clothing must be replaced with laboratory attire. Animal care workers cannot contact other animals during their shift. Section 600.11 Physical Establishment, Equipment, Animals, and Care Physical establishment, equipment, animals, and care must be adequate for licensed product manufacturing, including appropriate environmental controls, sanitation programs, and maintenance of equipment in a condition that will prevent contamination. Section 600.12 Records "Records shall be made, concurrently with the performance, of each step in the manufacture and distribution of products, in such a manner that at any time successive steps in the manufacture and distribution of any lot may be traced by an inspector." Key requirements: - Records must be legible and indelible - Must identify the person immediately responsible - Include dates of the various steps - Be as detailed as necessary for clear understanding by one experienced in product manufacture - Records must include all relevant information for lot traceability Section 600.13 Retention Samples Retain sufficient quantities from each lot of each product released for distribution to permit reexamination and retesting if needed. Retention samples must be maintained under conditions that will maintain product integrity. Section 600.14 Reporting of Biological Product Deviations by Licensed Manufacturers Who must report: Licensed manufacturers holding a biological product license who had control over the product when the deviation occurred. This applies even when manufacturing steps are contracted to others, provided procedures exist for receiving information about deviations and adverse events. Exceptions: - In vitro diagnostic product manufacturers (report under Part 803) - Blood and blood component manufacturers (report under § 606.171) - Source plasma manufacturers reporting deviations during plasma manufacture (report under § 606.171) What must be reported: Events associated with manufacturing, testing, processing, packing, labeling, storage, holding, or distribution if the event: - Represents a deviation from CGMP, applicable regulations, specifications, or established standards - Represents an unexpected or unforeseeable event affecting safety, purity, or potency - Occurs in your facility or contracted facilities - Involves a distributed biological product Reporting timeline: "You should report a biological product deviation as soon as possible but you must report at a date not to exceed 45-calendar days from the date you acquire information reasonably suggesting that a reportable event has occurred." Submission: Form FDA-3486, submitted to CBER or CDER depending on product type. Section 600.15 Temperatures During Shipment Products requiring refrigeration must be maintained at appropriate temperatures during shipment. Biological products must arrive at distribution facilities in a condition consistent with requirements for maintaining product safety, purity, and potency. Subpart C — Establishment Inspection Section 600.20 Inspectors Authorized representatives of the Secretary may access and inspect any licensed establishment. Manufacturers must permit and facilitate inspection. Section 600.21 Time of Inspection Establishments may be inspected at reasonable times during normal business hours and at other times when warranted by the circumstances. Section 600.22 [Reserved] Subpart D — Reporting of Adverse Experiences Section 600.80 Postmarketing Reporting of Adverse Experiences Biological product license holders must promptly review and report adverse experiences from all sources — commercial marketing, postmarketing studies, scientific literature, and foreign data. 15-Day Alert Reports: Must report "serious and unexpected" adverse experiences "as soon as possible but no later than 15 calendar days from initial receipt of the information." Periodic Reports: - Quarterly for 3 years from license issuance, then annually - Submitted within 30 days (quarterly) or 60 days (annual) of reporting period close Required information — Nonvaccine products: Patient data, adverse experience details, suspect product information, reporter identification, and applicant contact details must be included in Individual Case Safety Reports (ICSRs). Required information — Vaccine products: Patient name, address, vaccination dates, facility details, and healthcare provider information are mandated. Electronic submission: All safety reports must be submitted electronically per FDA guidance. Record retention: Adverse experience records must be maintained for 10 years. Exemptions: Whole blood, blood components, and in vitro diagnostic products are excluded. Privacy: Patient names and addresses should be coded for nonvaccine products; vaccine data become part of CDC surveillance systems. Section 600.81 Distribution Reports License holders must submit distribution reports containing the quantity of each product distributed in the United States during the reporting period. Section 600.82 Notification of Permanent Discontinuance or Manufacturing Interruption Manufacturers must notify FDA when permanently discontinuing manufacture or when manufacturing is interrupted in a manner that is likely to disrupt supply. Section 600.90 Waivers FDA may grant waivers to specific requirements upon written request with adequate justification. PART 601 — LICENSING Subpart A — General Provisions Section 601.2 Biologics License Application Requirements Manufacturers must submit applications to the Director of CBER or CDER. Applications require: - Data from nonclinical laboratory and clinical studies demonstrating product meets safety, purity, and potency requirements - Statements on compliance with parts 58 (nonclinical labs) and 56 (institutional review boards) - Manufacturing methods and stability data - Product samples and representative lot test results - Label specimens and container information - All manufacturing location addresses - Financial disclosure statements per part 54 - Environmental assessment or categorical exclusion claim Special categories exempt from certain requirements (§§ 600.10–600.13, 610.53, 610.62): - Therapeutic DNA plasmid products - Synthetic peptide products (40 or fewer amino acids) - Monoclonal antibodies for in vivo use - Recombinant DNA-derived therapeutic products Withdrawal reporting: License holders must report product withdrawals within 30 working days, including holder name, product name, BLA number, National Drug Code, and expected withdrawal date. Master files: Generally, biologics applications cannot incorporate drug substance information by reference, with limited exceptions for legacy applications and non-biological combination product components. Section 601.4 Licenses — Issuance and Denial FDA will issue a license when the application demonstrates compliance with applicable requirements. FDA may deny a license application if requirements are not met. Section 601.6 Suspension of License FDA may suspend a biologics license if continued manufacturing presents an imminent hazard to public health. Section 601.7 Revocation of License FDA may revoke a biologics license for cause, including failure to maintain manufacturing standards, fraudulent application, or safety/purity/potency failures. Section 601.8 Misbranding A biological product is misbranded if its label or labeling is false or misleading in any particular. Section 601.9 Licenses — Products; Procedures Describes procedures for licensing biologics manufactured at multiple locations, by multiple manufacturers, or under cooperative manufacturing arrangements. Subpart C — Biologics Licensing Section 601.12 Changes to an Approved Application Holders of approved applications must describe and report all changes using supplements or annual reports: (a) Major changes — require Prior Approval Supplement (PAS) before distribution. Include changes that have a substantial potential to have an adverse effect on safety or effectiveness. (b) Moderate changes — require Supplement — Changes Being Effected (CBE) or CBE-30 before or 30 days prior to distribution. (c) Minor changes — can be reported in annual report (Changes in Annual Report, CAR). Section 601.14 Regulatory Submissions in Electronic Format Electronic submissions to CBER are required for biologics license applications. Section 601.20 Biologics Licenses — Issuance License issuance is contingent on FDA inspection of the manufacturing facility and documentation that manufacturing standards are met. Section 601.25 Review Procedures FDA review procedures for biologics license applications including standard and priority reviews. Section 601.26 Acceptance Review for Combination Products with a Biological Product Primary Mode of Action Acceptance review procedures for combination products. Section 601.27 Pediatric Studies Requirements for conducting pediatric studies and reporting results. Section 601.28 Annual Reports License holders must submit annual reports containing information about changes to the product, manufacturing, and labeling since the last annual report. Section 601.29 Withdrawal of Application Applicants may withdraw pending applications. Subpart D — Diagnostic Radiopharmaceuticals Sections 601.30–601.35 — Standards specific to diagnostic radiopharmaceutical products, including imaging agents labeled with radioisotopes. Subpart E — Accelerated Approval Sections 601.40–601.46 — Accelerated approval pathway for biological products for serious or life-threatening illnesses based on a surrogate endpoint or intermediate clinical endpoint reasonably likely to predict clinical benefit. Post-approval studies are required to verify clinical benefit. Subpart F — Confidentiality of Information Sections 601.50–601.51 — Trade secret and proprietary data protections for information submitted in biologics license applications. Subpart G — Postmarketing Studies Section 601.70 — Requirements for postmarketing studies committed to as a condition of approval. Includes annual status reporting. Subpart H — Approval When Human Efficacy Studies Are Not Ethical or Feasible Sections 601.90–601.95 — The "Animal Rule" — allows approval based on animal model efficacy data when human efficacy trials are not feasible (e.g., chemical or biological threat agents). Rigorous manufacturing standards apply. PART 610 — GENERAL BIOLOGICAL PRODUCTS STANDARDS Subpart A — Release Requirements Section 610.1 Required Tests No product may be released by the manufacturer prior to the completion of tests for conformity with standards applicable to such product. The following standards apply to all biological products unless otherwise specified. Section 610.2 Release of Products: Failure to Meet Standards Products failing to meet applicable standards may not be released. FDA must be notified and product must be quarantined or destroyed per applicable procedures. Subpart B — General Provisions (Test Requirements) Section 610.9 Equivalent Methods and Processes Modifications to required test methods or manufacturing processes are permitted only when: (a) The applicant presents evidence through a license application or supplement demonstrating "the modification will provide assurances of the safety, purity, potency, and effectiveness" equal to or greater than the original specified method. (b) Written approval is obtained from the Director of CBER or CDER. Section 610.10 Potency "Tests for potency shall consist of either in vitro or in vivo tests, or both, which have been specifically designed for each product so as to indicate its potency in a manner adequate to satisfy the interpretation of potency given by the definition in § 600.3(s) of this chapter." Key requirements: - Test type options: in vitro, in vivo, or combined testing - Product-specific design: each biological product requires customized testing protocols - Tests must align with the potency definition in § 600.3(s): "The specific ability or capacity of the product to effect a given result" - Limits of potency shall be set forth in the standards for each product Section 610.11 General Safety Each lot of biological product must be tested for general safety. A product fails general safety requirements if it contains harmful or toxic substances not related to its intended use. Section 610.12 Sterility Manufacturers must perform sterility testing of each lot of each biological product's final container material or other material as approved in the biologics license application. Test validation: The sterility test must be "validated to demonstrate that the test is capable of reliably and consistently detecting the presence of viable contaminating microorganisms." Written procedures required: - Test method description - Sampling methodology - Lot acceptance/rejection specifications - Sample considerations: lot size, manufacturing duration, container configuration, inhibitor/preservative concentrations, appropriate product dilution factors Testing methods: - Culture-based methods: specified media composition, growth-promotion testing, and incubation conditions required - Non-culture-based methods: defined test parameters, acceptance criteria, and controls required Repeat testing: If initial tests detect microorganisms, one repeat test is permitted only if laboratory error or faulty materials caused the positive result. Exceptions: Certain products (whole blood, vaccines, reagents) are exempt. The FDA Director may waive requirements if route of administration or preparation method precludes sterility concerns. Section 610.13 Purity Each lot of biological product must be "free of extraneous material except that which is unavoidable in the manufacturing process" as approved in the biologics license application. (a) Residual moisture testing: Each dried product lot must undergo testing for residual moisture and meet established limits per approved methods. The CBER Director may exempt this test if unnecessary for product safety, purity, and potency. (b) Pyrogenic substances testing: All final containers intended for injection must be tested for pyrogenic substances via intravenous rabbit injection. Exemptions apply to certain products including vaccines, plasma, and diagnostic substances. Section 610.14 Identity "The contents of a final container of each filling of each lot shall be tested for identity after all labeling operations" are complete. Test specificity: The identity test must be "specific for each product in a manner that will adequately identify it as the product designated on final container and package labels and circulars, and distinguish it from any other product being processed in the same laboratory." Acceptable methods for establishing identity: - Physical or chemical characteristics of the product - Inspection by macroscopic or microscopic methods - Specific cultural tests - In vitro or in vivo immunological tests Section 610.15 Constituent Materials Constituent materials used in manufacturing, including media, diluents, and adjuvants, must meet established standards and not adversely affect product safety, purity, or potency. Section 610.16 Conformity with Standards Each lot must conform to applicable standards for the product as established in the biologics license application. Section 610.17 Jurisdictional Blood Requirements Where applicable, blood used in manufacturing must meet applicable donor eligibility requirements. Section 610.18 Cultures Storage and maintenance: Cultures must be "stored in a secure and orderly manner, at a temperature and by a method that will retain the initial characteristics" while ensuring contamination-free conditions. Identity and verification: Each culture requires clear source identification. New stock preparations need complete strain identification; seed lots must have lot numbers and preparation dates. "Periodic tests shall be performed as often as necessary to verify the integrity of the strain characteristics and freedom from extraneous organisms," with results documented. Cell lines requirements: Cell lines used in manufacturing must be: - Identified by history - Described regarding cytogenetic characteristics and tumorigenicity - Characterized for in vitro growth traits and life potential - Tested for detectable microbial agents The Director of CBER or CDER may require additional safety, purity, and potency tests. Primary cell cultures not subcultivated or subcultivated minimally are exempt. Records: Appropriate records "shall be prepared and maintained as required" per 21 CFR §§ 211.188 and 211.194. Subpart E — Testing Requirements for Relevant Transfusion-Transmitted Infections Sections 610.39–610.48 Testing requirements for transfusion-transmitted infections applicable to blood and blood components. Each unit must be tested for specified infectious disease markers (HIV, HCV, HBV, syphilis, etc.) using FDA-licensed or approved tests. Reactive test results require quarantine and notification procedures. Subpart F — Dating Period Limitations Section 610.50 Selling, Barter, or Exchange No product may be sold, bartered, or exchanged after its expiration date. Section 610.53 Dating Periods for Specific Products Dating periods (expiration dating) are established for individual biological products through the license application. Products must be labeled with expiration dates and may not be distributed beyond the established dating period unless additional testing demonstrates continued conformance. Subpart G — Labeling Standards Section 610.60 Container Label Biological product containers capable of bearing a complete label must display: 1. Product name (proper designation) 2. Manufacturer information (name, address, and license number) 3. Lot identification (lot number or equivalent identifier) 4. Expiration date 5. Dosage (recommended individual dose for multi-dose containers) 6. Prescription designation ("Rx only" statement for prescription biologicals) 7. Medication Guide required statement per 21 CFR 208.24(d) when applicable Alternative label scenarios: - Package label (§ b): If container lacks packaging, all package label requirements transfer to the container itself - Partial labels (§ c): For containers with space limitations, include minimum information: product name, lot identification, manufacturer name, and recommended dose. These must be placed within outer packaging containing full package label details - No container label (§ d): Unlabelable containers may omit label information if enclosed in properly labeled outer packaging - Visual inspection (§ e): A sufficient uncovered container area must remain accessible along the full length or circumference to permit content inspection Section 610.61 Package Label The package label must include all information required on the container label plus: - Number of containers in the package (if multiple) - Volume of product in container - Storage temperature requirements - Diluent information if applicable - Name and address of the distributor if different from manufacturer - Statement of ingredients where required Section 610.62 Proper Name; Distinguishing Name The proper name of the product must appear prominently on the label and be the name used throughout all labeling. Section 610.63 Lot Number The lot number must be a unique identifier traceable to manufacturing history of that specific lot. Section 610.64 Expiration Date The expiration date must appear in an unambiguous format and must correlate with the dating period established in the license. Section 610.65 Recommended Storage Temperature The label must state the required storage temperature to maintain product safety, purity, and potency throughout the dating period. Section 610.67 Labeling Changes Changes to labeling must be approved per 21 CFR 601.12 prior to implementation. Section 610.68 Exemptions and Alternatives FDA may grant exemptions to specific labeling requirements upon written request with adequate justification. PARTS 606, 607, 630, 640, 660, AND 680 — SPECIALTY PRODUCT REQUIREMENTS Part 606 — Current Good Manufacturing Practice for Blood and Blood Components Establishes CGMP requirements specific to blood and blood component manufacturing. Includes requirements for personnel, equipment, supplies, facilities, laboratory controls, distribution, and production and process controls. Blood deviation reporting under § 606.171 is analogous to § 600.14 for other biological products. Part 607 — Establishment Registration and Product Listing for Manufacturers of Human Blood and Blood Products Registration requirements for blood establishments with FDA. Manufacturers must register and list their products biannually. Part 630 — Requirements for Blood and Blood Products Establishes donor eligibility requirements and testing procedures for blood and blood components. Includes requirements for donor screening, deferral, and reinstatement. All donors must be tested for specified transfusion-transmitted infections before collected blood is used. Part 640 — Additional Standards for Human Blood and Blood Components Additional product-specific standards for various blood components (Whole Blood, Red Blood Cells, Platelets, Fresh Frozen Plasma, Cryoprecipitate, etc.) covering filling, labeling, storage, dating, and identity requirements. Part 660 — Additional Standards for Diagnostic Substances for Laboratory Tests Standards for diagnostic substances used in laboratory testing, including antigen and antibody reagents. Requirements for identity, purity, potency, and labeling specific to diagnostic applications. Method validation and defensible analytical decision-making requirements. Part 680 — Additional Standards for Miscellaneous Products Additional standards for allergenic products (allergy testing and immunotherapy), including standardized identity, controlled labeling, and manufacturing evidence requirements. Allergen extracts must meet identity, potency, and safety standards. APPLICABILITY TO STERILE BIOLOGICS CDMO OPERATIONS For a contract development and manufacturing organization (CDMO) involved in sterile biologics fill-finish: Primary applicable regulations: - Part 600 (establishment standards, deviation reporting, adverse experience reporting) applies in full - Part 601 (licensing) applies to the product license holder; CDMO must support BLA compliance through contract manufacturing agreements and quality agreements - Part 610 (general standards) — sterility (610.12), purity (610.13), identity (610.14), potency (610.10), and labeling (610.60–610.68) standards apply to every lot released CDMO-specific considerations: - Deviation reporting (600.14) applies to the license holder, but CDMO must have systems to detect deviations and notify license holders within timeframes supporting the 45-day reporting window - Manufacturing changes (601.12) must be coordinated with license holders — CDMO-initiated changes require sponsor approval before implementation - Quality agreements must define responsibilities for lot release testing, deviation investigation, CAPA, and regulatory reporting - Records (600.12) maintained by the CDMO must support license holder's traceability requirements - Sterility testing (610.12) validation must be product-specific and approved in the BLA — CDMO must validate for each product - Identity testing (610.14) must distinguish products manufactured in the same laboratory — particularly important in multi-product facilities --- ### Document: FDA 21CFR Part11 Complete (FDA) # 21 CFR Part 11 — Electronic Records; Electronic Signatures: FDA Requirements for Electronic Records and Electronic Signatures in Regulated Industries 21 CFR PART 11 — ELECTRONIC RECORDS; ELECTRONIC SIGNATURES Source: eCFR / Cornell LII (current through April 2026) URL: https://www.ecfr.gov/current/title-21/chapter-I/subchapter-A/part-11 ================================================================================ OVERVIEW AND REGULATORY CONTEXT ================================================================================ 21 CFR Part 11 was promulgated by the FDA in 1997 (62 FR 13430) and establishes criteria under which the agency considers electronic records and electronic signatures trustworthy, reliable, and generally equivalent to paper records and handwritten signatures executed on paper. It applies to all FDA-regulated industries: pharmaceuticals, biologics, medical devices, food, cosmetics, and tobacco. The regulation responds to the rapid adoption of computerized systems in regulated industries during the 1990s. Before Part 11, no clear federal standard existed for the acceptability of electronic records as alternatives to paper records required by FDA regulations. FDA 2003 GUIDANCE ON SCOPE AND APPLICATION In August 2003, FDA issued a guidance document "21 CFR Part 11; Electronic Records; Electronic Signatures — Scope and Application" which significantly narrowed the agency's enforcement focus. Key points: 1. PREDICATE RULE CONCEPT: Part 11 applies only to electronic records that FDA regulations require to be maintained or submitted and where the regulated entity chooses to use electronic records instead of paper records. The underlying FDA regulation requiring the record is called the "predicate rule" (e.g., 21 CFR 211.68 — computers in drug manufacturing; 21 CFR 211.186 — master production and control records; 21 CFR 211.188 — batch production records). 2. ENFORCEMENT DISCRETION: FDA exercises enforcement discretion regarding certain Part 11 requirements for: - Legacy systems installed before Part 11's effective date (August 20, 1997) if those systems use paper as the official record supplemented by electronic records - Validation requirements for legacy systems that are compliant in all other aspects 3. WHAT PART 11 DOES NOT REQUIRE: Part 11 does NOT mandate that any entity use electronic records or electronic signatures. It only governs the standards IF electronic records/signatures are used. 4. RISK-BASED APPROACH: FDA encourages a risk-based approach to Part 11 compliance. Not all predicate rule records carry equal risk. The investment in controls should be commensurate with the risk to product quality and patient safety. PART 11 AND ALCOA+ Part 11's requirements align directly with ALCOA+ data integrity principles: - Attributable: §11.10(g) authority checks; §11.50 signature manifestations - Legible: §11.10(b) ability to generate readable copies - Contemporaneous: §11.10(e) time-stamped audit trails - Original: §11.10(e) computer-generated audit trails (not user-modifiable) - Accurate: §11.10(a) system validation The "+" elements (Complete, Consistent, Enduring, Available) are addressed by: - Complete/Consistent: §11.10(e) audit trail captures ALL operator actions - Enduring: §11.10(c) records protected for retention period - Available: §11.10(b) copies available for FDA review/inspection CDMO RELEVANCE In a pharmaceutical CDMO context, Part 11 applies to: - Electronic Batch Records (eBR): replacing paper batch manufacturing records required by 21 CFR 211.188 - LIMS (Laboratory Information Management Systems): electronic lab data required by 21 CFR 211.194 - SCADA/DCS (Supervisory Control and Data Acquisition / Distributed Control Systems): process control data required by 21 CFR 211.68 - Building Management Systems (BMS): environmental monitoring temperature/ humidity data for sterile manufacturing - Computer-assisted manufacturing equipment: automated dispensing systems, in-line inspection systems, automated visual inspection - MES (Manufacturing Execution Systems): electronic work instructions and confirmations ================================================================================ SUBPART A — GENERAL PROVISIONS §§ 11.1 — 11.3 ================================================================================ § 11.1 SCOPE (a) The regulations in this part set forth the criteria under which the agency considers electronic records, electronic signatures, and handwritten signatures executed to electronic records to be trustworthy, reliable, and generally equivalent to paper records and handwritten signatures executed on paper. (b) This part applies to records in electronic form that are created, modified, maintained, archived, retrieved, or transmitted, under any requirements set forth in agency regulations. This part also applies to electronic records submitted to the agency under requirements of the Federal Food, Drug, and Cosmetic Act and the Public Health Service Act, even if such records are not specifically identified in agency regulations. However, this part does not apply to paper records that are, or have been, transmitted by electronic means. (c) Where electronic signatures and their associated electronic records meet the requirements of this part, the agency will consider the electronic signatures to be equivalent to full handwritten signatures, initials, and other general signings as required by agency regulations, unless specifically excepted by regulation(s) effective on or after August 20, 1997. (d) Electronic records that meet the requirements of this part may be used in lieu of paper records, in accordance with § 11.2, unless paper records are specifically required. (e) Computer systems (including hardware and software), controls, and attendant documentation maintained under this part shall be readily available for, and subject to, FDA inspection. KEY INTERPRETATION: §11.1 does not apply to paper records simply transmitted electronically (e.g., a scanned PDF of a paper record sent by email). The electronic record must itself be created, modified, maintained, or archived in electronic form. § 11.2 IMPLEMENTATION (a) For records required to be maintained but not submitted to the agency, persons may use electronic records in lieu of paper records or electronic signatures in lieu of traditional signatures, in whole or in part, provided that the requirements of this part are met. (b) For records submitted to the agency, persons may use electronic records in lieu of paper records or electronic signatures in lieu of traditional signatures, in whole or in part, provided that: (1) The requirements of this part are met; and (2) The document or parts of a document to be submitted have been identified in public docket No. 92S-0251 as being the type of submission the agency accepts in electronic form. This docket will identify specifically what types of documents or parts of documents are acceptable for electronic submission. The agency will periodically publish in the Federal Register a list of the types of documents it will accept electronically. § 11.3 DEFINITIONS As used in this part: (a) Act means the Federal Food, Drug, and Cosmetic Act (sec. 201-903 of the act (21 U.S.C. 321-394)). (b) Agency means the Food and Drug Administration. (c) Biometric means a method of verifying an individual's identity based on measurement of the individual's physical feature(s) or repeatable action(s) where those features and/or actions are both unique to that individual and measurable. (d) Closed system means an environment in which system access is controlled by persons who are responsible for the content of electronic records that are on the system. EXAMPLE: A dedicated pharmaceutical manufacturing control system (DCS/SCADA) where only authorized company personnel can access and whose access is managed by the company's IT/quality team is a closed system. The company controls both who can log in and what records are stored. (e) Digital signature means an electronic signature based upon cryptographic methods of originator authentication, computed by using a set of rules and a set of parameters such that the identity of the signer and the integrity of the data can be verified. NOTE: Digital signatures (using cryptography like RSA or ECDSA) are a SUBSET of electronic signatures. Not all electronic signatures are digital signatures. PKI-based systems use digital signatures. (f) Electronic record means any combination of text, graphics, data, audio, pictorial, or other information representation in digital form that is created, modified, maintained, archived, retrieved, or distributed by a computer system. (g) Electronic signature means a computer data compilation of any symbol or series of symbols executed, adopted, or authorized by an individual to be the legally binding equivalent of the individual's handwritten signature. (h) Handwritten signature means the scripted name or legal mark of an individual handwritten by that individual and executed or adopted with the present intention to authenticate a writing in an electronic form. The act of signing with a writing or marking instrument such as a pen or stylus is preserved. The scripted name or legal mark, while conventionally applied to paper, may also be applied to other devices that capture the name or mark. (i) Open system means an environment in which system access is not controlled by persons who are responsible for the content of electronic records that are on the system. EXAMPLE: A cloud-based system accessed over the public internet, or a third-party hosted system where the cloud provider (not the pharmaceutical company) controls system access, is an open system. Email systems are open systems. Systems accessed via public telecommunication infrastructure are open systems. OPEN vs CLOSED SYSTEM KEY DISTINCTION: The determining factor is NOT the technology (internet vs intranet) but WHO controls access. If the persons responsible for the electronic records control system access CLOSED. If access is controlled by others OPEN. ================================================================================ SUBPART B — ELECTRONIC RECORDS §§ 11.10 — 11.30 ================================================================================ § 11.10 CONTROLS FOR CLOSED SYSTEMS Persons who use closed systems to create, modify, maintain, or transmit electronic records shall employ procedures and controls designed to ensure the authenticity, integrity, and, when appropriate, the confidentiality of electronic records, and to ensure that the signer cannot readily repudiate the signed record as not genuine. Such procedures and controls shall include the following: (a) VALIDATION Validation of systems to ensure accuracy, reliability, consistent intended performance, and the ability to discern invalid or altered records. Validation Scope: This encompasses Installation Qualification (IQ), Operational Qualification (OQ), and Performance Qualification (PQ). The depth of validation should be commensurate with risk. Systems that create, modify, or maintain records that support product release decisions require rigorous validation. FDA 2003 Guidance interpretation: For legacy systems (predating August 1997), FDA exercises enforcement discretion on validation requirements provided the system otherwise meets Part 11. New systems must be fully validated. Computer System Validation (CSV) requirements under §11.10(a): - Written validation plan (VMP or CVMP) - URS (User Requirements Specification) - FS (Functional Specification) / DS (Design Specification) - IQ/OQ/PQ protocols and reports - Traceability matrix linking requirements to test scripts - Periodic revalidation when changes occur (change control) (b) READABLE COPIES The ability to generate accurate and complete copies of records in both human readable and electronic form suitable for inspection, review, and copying by the agency. This requirement ensures that if FDA inspectors arrive on-site, they can receive complete, accurate, human-readable copies of all electronic records. Systems must export records to formats accessible to the agency (PDF, CSV, printed copies). Data migration to new systems must preserve readability of archived records. (c) PROTECTION OF RECORDS Protection of records to enable their accurate and ready retrieval throughout the records retention period. Records must be protected from: - Unauthorized alteration or deletion - Data corruption from hardware failure - Loss from disaster (backup/disaster recovery requirements) - Degradation of storage media over time Retention periods are defined by predicate rules (e.g., 21 CFR 211.180 — drug records must be retained at least 1 year after drug expiry, typically 2-3 years minimum for most pharmaceutical records, up to lifetime for biologics). (d) LIMITING SYSTEM ACCESS Limiting system access to authorized individuals. Access controls implementation: - Role-based access control (RBAC) — users assigned roles with defined permissions matching their job function and training - Individual user accounts — no shared/generic accounts (except emergency access with appropriate controls and documentation) - User access reviews — periodic review of user accounts and permissions - Deprovisioning — timely removal of access when personnel change roles or leave - Physical access controls for workstations running regulated systems The prohibition on shared accounts is a common FDA 483 observation: "Shared usernames/passwords observed in [LIMS/DCS/eBR system]." (e) AUDIT TRAILS Secure, computer-generated, time-stamped audit trails to independently record the date and time of operator entries and actions that create, modify, or delete electronic records. Record changes shall not obscure previously recorded information. Such audit trail documentation shall be retained for a period at least as long as that required for the subject electronic records and shall be available for agency review and copying. CRITICAL ELEMENTS OF §11.10(e) AUDIT TRAILS: 1. SECURE: Audit trails cannot be turned off, modified, or deleted by system users. Only system administrators with documented authorization can adjust audit trail settings, and such changes must themselves be logged. 2. COMPUTER-GENERATED: The system automatically creates audit entries — they are NOT manually entered by users. This is the core distinction from paper- based records where an operator writes in a logbook. 3. TIME-STAMPED: Each entry records the date and time, which should be synchronized to a reliable time source (network time protocol — NTP). Time zone documentation is important for multi-site systems. 4. INDEPENDENTLY RECORDING: The audit trail records actions independent of the data record itself. Audit trails cannot be part of the same file that can be edited. 5. CREATE/MODIFY/DELETE: ALL three operations must be captured, not just modifications. This means the audit trail should record: - Original entry (with timestamp and user ID) - Any change (old value new value, reason for change, timestamp, user) - Any deletion (original value, reason, timestamp, user) 6. NOT OBSCURING: Changed records must show BOTH old and new values. A system that simply overwrites old data with new data WITHOUT capturing the original value does NOT meet §11.10(e). 7. RETAINED AS LONG AS THE RECORD: If a batch record must be retained for 3 years, the audit trail for that batch record must also be retained for 3 years. 8. AVAILABLE FOR FDA REVIEW: FDA inspectors must be able to access and copy audit trails during inspections. COMMON AUDIT TRAIL DEFICIENCIES (FDA 483 OBSERVATIONS): - Audit trail not enabled or incomplete (not capturing all events) - Audit trail can be modified by non-privileged users - Old values not captured (only new value recorded) - Reason for change not required or captured - Audit trail retention shorter than record retention period - Audit trail not reviewed as part of quality oversight (f) OPERATIONAL SYSTEM CHECKS Use of operational system checks to enforce permitted sequencing of steps and events, as appropriate. This controls the workflow sequence in electronic systems. For example: - In an eBR system, an operator cannot sign the "product dispensed" step before the "formulation complete" step - In a LIMS, results cannot be approved before all required tests are entered - In a DCS, a sterilization cycle cannot be released before all critical parameters (time, temperature, pressure) are verified within specification (g) AUTHORITY CHECKS Use of authority checks to ensure that only authorized individuals can use the system, electronically sign a record, access the operation or computer system input or output device, alter a record, or perform the operation at issue. Authority checks go beyond access controls (§11.10d) to specifically govern: - WHO can perform electronic signatures (only persons with validated signing authority in the system) - WHO can approve specific records (e.g., only QC manager can approve certificate of analysis) - WHO can modify approved records (e.g., only QA can make post-approval amendments with justification) (h) DEVICE CHECKS Use of device checks to determine, as appropriate, the validity of the source of data input or operational instruction. Device checks ensure that: - Input devices (scales, pH meters, analytical instruments) are calibrated and verified - Data from automated systems is validated as coming from authorized, functioning instruments - Checksums or other validation methods verify data integrity during transmission from instruments to systems (i) EDUCATION, TRAINING AND EXPERIENCE Determination that persons who develop, maintain, or use electronic record/ electronic signature systems have the education, training, and experience to perform their assigned tasks. This mirrors 21 CFR 211.68 training requirements but specifically for computer systems. Training must be: - Role-specific (what the person needs to know for their specific system role) - Documented (training records are themselves electronic records if kept in an LMS or HRIS) - Current (retraining required when system changes) (j) WRITTEN POLICIES The establishment of, and adherence to, written policies that hold individuals accountable and responsible for actions initiated under their electronic signatures. This creates the legal/administrative framework ensuring that electronic signatures carry the same accountability weight as handwritten signatures. SOPs must: - Define what constitutes an electronic signature at the company - Specify prohibited actions (sharing credentials, signing for others) - Establish consequences for misuse (disciplinary action) - Reference the FDA letter requirement in §11.100(c) (k) USE OF APPROPRIATE CONTROLS FOR SYSTEMS DOCUMENTATION Use of appropriate controls over systems documentation including: (1) Adequate controls over the distribution of, access to, and use of documentation for system operation and maintenance. (2) Revision and change control procedures to maintain an audit trail that identifies the date of, and the nature of, changes to systems documentation, and the individuals making the change. Systems documentation includes: - System Administrator Manuals - User manuals and SOPs - Validation documents (IQ/OQ/PQ reports) - Computer System Validation Package These documents must be controlled under the company's document management system (DMS), itself typically a Part 11 compliant system. § 11.30 CONTROLS FOR OPEN SYSTEMS Persons who use open systems to create, modify, maintain, or transmit electronic records shall employ procedures and controls designed to ensure the authenticity, integrity, and, as appropriate, the confidentiality of electronic records from the point of their creation to the point of their receipt. Open systems require ALL controls in §11.10 PLUS additional safeguards: - Document encryption using appropriate encryption methods to ensure data cannot be read during transmission by unauthorized parties - Use of appropriate digital signature standards (e.g., FDA-recognized cryptographic standards) when additional security is needed - Additional physical security for workstations and transmission endpoints WHY OPEN SYSTEMS NEED MORE CONTROLS: In a closed system, the company controls who has access — physical and logical access controls are sufficient. In an open system (accessible via public networks), records can be intercepted during transmission. Encryption protects confidentiality. Digital signatures protect integrity (any alteration of the transmitted record would invalidate the digital signature). PRACTICAL EXAMPLE: A CRO submitting clinical data to a sponsor via a cloud platform. The CRO cannot fully control access to the cloud infrastructure (managed by AWS, Azure, etc.) — this is an open system. The data submission must be encrypted and digitally signed to meet §11.30. ================================================================================ SUBPART C — ELECTRONIC SIGNATURES §§ 11.50 — 11.300 ================================================================================ § 11.50 SIGNATURE MANIFESTATIONS (a) Signed electronic records shall contain information associated with the signing that clearly indicates all of the following: (1) The printed name of the signer; (2) The date and time when the signature was executed; and (3) The meaning (such as review, approval, responsibility, or authorship) associated with the signature. (b) The items identified in paragraphs (a)(1), (a)(2), and (a)(3) of this section shall be subject to the same controls as for electronic records and shall be included as part of any human readable form of the electronic record (such as electronic display or printout). THREE MANDATORY ELEMENTS OF §11.50 SIGNATURE MANIFESTATIONS: 1. PRINTED NAME: The full name of the signer — not just a user ID or employee number. The name must be human-readable. 2. DATE AND TIME: Timestamp of signature execution — not the date the record was created, but the exact date and time the signature was applied. This must be automatic (computer-generated), not manually entered by the signer. 3. MEANING: The purpose of the signature must be stated explicitly: - "Reviewed by" — for QC analysts reviewing test data - "Approved by" — for QA managers approving batch records - "Authored by" — for operators entering data - "Verified by" — for second-person verification steps COMMON DEFICIENCIES: - System displays only user ID (not printed name) in audit trail - Date/time is manually entered by the signer (not computer-generated) - Meaning is generic ("signed") rather than specific ("approved for release") - Signature manifestation not included in printed/exported copies of records § 11.70 SIGNATURE/RECORD LINKING Electronic signatures and handwritten signatures executed to electronic records shall be linked to their respective electronic records to ensure that the signatures cannot be excised, copied, or otherwise transferred to falsify an electronic record by ordinary means. ANTI-FALSIFICATION PURPOSE: §11.70 prevents what is called "signature cut-and-paste" fraud: extracting a valid electronic signature from a legitimate record and inserting it into a falsified record. Technical implementations include: - Cryptographic binding: The signature is computed over the record content (like a digital signature/hash). Any modification to the record invalidates the signature. - Database linking: The signature record contains an immutable foreign key reference to the specific version of the electronic record (identified by a hash or unique record ID). - Time-lock: Once signed, the record is frozen — no edits allowed without going through an amendment workflow that requires re-signature. FDA INSPECTION FOCUS: Inspectors may test this by asking: "If I print this batch record, can the signature block be cut and pasted into another document?" The system design must make this technically impossible or detectable. § 11.100 GENERAL REQUIREMENTS FOR ELECTRONIC SIGNATURES (a) Each electronic signature shall be unique to one individual and shall not be reused by, or reassigned to, anyone else. UNIQUENESS PRINCIPLE: One electronic signature (the combination of user ID, password, and/or biometric) maps to exactly one person. No sharing, no delegation. This is why shared accounts are fundamentally incompatible with Part 11 — if two people share an ID/password, the signature is not unique to one individual. (b) Before an organization establishes, assigns, certifies, or otherwise sanctions an individual's electronic signature, or any element of such electronic signature, the organization shall verify the identity of the individual. IDENTITY VERIFICATION: The company must verify who a person is before assigning them an electronic signature. Acceptable methods: - Government-issued photo ID verification during onboarding/HR process - Biometric enrollment process (fingerprint, iris scan) - In-person verification by HR or Supervisor This requirement means "provisioning" an account requires documented identity verification — not just completing a form. (c) Persons using electronic signatures shall, prior to or at the time of such use, certify to the agency in writing that the electronic signatures in their system are intended to be the legally binding equivalent of traditional handwritten signatures. Upon agency request, such certification shall be submitted in paper form with a traditional signature to the docket established by the agency for such purposes. FDA LETTER REQUIREMENT: §11.100(c) requires companies to submit a letter to FDA certifying that their electronic signatures are legally binding equivalents of handwritten signatures. This is typically a one-time submission per company (not per system or per user), sent to: FDA Office of Regional Operations (ORO), Docket No. 92S-0251. (d) If an individual is using electronic signatures in a way not in compliance with this paragraph, the electronic signature is not considered to be the equivalent of a traditional handwritten signature. § 11.200 ELECTRONIC SIGNATURE COMPONENTS AND CONTROLS (a) Electronic signatures that are not based upon biometrics shall: (1) Employ at least two distinct identification components such as an identification code and password. (2) Be used only by their genuine owners; and (3) Be administered and executed to ensure that attempted use of an individual's electronic signature by anyone other than its genuine owner requires collaboration of two or more individuals. WHEN BOTH COMPONENTS ARE REQUIRED (NON-BIOMETRIC): - First use in a single work session: Must use BOTH identification components (ID code + password) - Subsequent uses in a continuous session: At least one component must be used (e.g., just re-entering the password is sufficient) - For non-continuous sessions (new login, session timeout/expiry): Must use BOTH components again PRACTICAL IMPLEMENTATION: - Standard login: username + password (both components) - Within-session re-authentication for signing: password only (one component) - After session timeout: username + password again (both components) - Some systems add a third factor (MFA) for enhanced security — this exceeds Part 11 minimum requirements (b) Electronic signatures based upon biometrics shall be designed to ensure that they cannot be used by anyone other than their genuine owners. BIOMETRIC ELECTRONIC SIGNATURES: Biometrics (fingerprint, retinal scan, facial recognition, voice recognition) are inherently individual — you cannot transfer your fingerprint to another person. Therefore, the two-component requirement of (a) does not apply to biometric signatures. Instead, the system design must ensure: - The biometric template cannot be spoofed (anti-spoofing measures) - False acceptance rate (FAR) is sufficiently low for the risk level - Biometric data storage is secure § 11.300 CONTROLS FOR IDENTIFICATION CODES/PASSWORDS Persons who use electronic signatures based upon use of identification codes in combination with passwords shall employ controls to ensure their security and integrity. Such controls shall include: (a) Maintaining the uniqueness of each combined identification code and password, such that no two individuals have the same combination of identification code and password. (b) Ensuring that identification code and password issuances are periodically checked, recalled, or revised (e.g., to cover such events as password aging, with appropriate token revisions as necessary). PASSWORD MANAGEMENT REQUIREMENTS: - Password expiration policy (typical: 90 days maximum) - Password complexity requirements (length, character types) - Prevention of password reuse (password history) - Account lockout after failed attempts (prevent brute force) - These are not explicitly stated in the regulation but are expected as "controls to ensure security and integrity" (c) Following loss management procedures to electronically de-authorize lost, stolen, missing, or otherwise potentially compromised tokens, cards, and other devices that bear or generate identification code or password information, and to issue temporary or permanent replacements using suitable, rigorous controls. LOST/STOLEN CREDENTIAL RESPONSE: - Immediate reporting procedure when credentials are lost or stolen - Immediate account deactivation/disabling upon report - Issuance of new credentials with identity re-verification - Documentation of the incident and response - These procedures must be defined in SOPs and followed consistently (d) Use of transaction safeguards to prevent unauthorized use of passwords and/or identification codes, and to detect and report in an immediate and urgent manner any attempts at their unauthorized use to the system security unit, and, as appropriate, to organizational management. TRANSACTION SAFEGUARDS: - Failed login attempt monitoring and alerting - Account lockout after N failed attempts (N typically 3-5) - Real-time alerts to system security personnel when lockout occurs - Intrusion detection for patterns suggesting unauthorized access attempts - Logging of all authentication attempts (successful and failed) (e) Initial and periodic testing of devices, such as tokens or cards, that bear or generate identification code or password information to ensure that they function properly and have not been altered in a unauthorized manner. TOKEN/DEVICE TESTING: For systems using hardware tokens (RSA SecurID, smart cards, USB security keys), these devices must be: - Tested on initial issuance to verify they work as intended - Periodically tested to verify continued function - Inspected for signs of tampering or unauthorized modification ================================================================================ CROSS-REFERENCE: PART 11 AND OTHER FDA REGULATIONS ================================================================================ PREDICATE RULES — KEY CROSS-REFERENCES: 21 CFR 211.68 (Automatic, Mechanical, and Electronic Equipment): - Requires validation of computerized systems used in drug manufacturing - Establishes that computer printouts of data shall be checked against original data - Part 11 elaborates on what "validation" means for systems creating electronic records 21 CFR 211.186 (Master Production and Control Records): - Requires master batch records; if maintained electronically, Part 11 applies - Electronic master production records must meet §11.10 controls 21 CFR 211.188 (Batch Production and Control Records): - Batch records are the primary CDMO document — eBRs must meet Part 11 - Every entry in an eBR is an electronic record under Part 11 - Every signature in an eBR is an electronic signature 21 CFR 211.194 (Laboratory Records): - LIMS-generated analytical records are electronic records under Part 11 - Instrument data files (HPLC, UV-Vis, GC) are electronic records - Original raw data files must be retained (§11.10c) 21 CFR 211.180 (General Requirements for Records and Reports): - Sets record retention periods - Part 11 §11.10(c) and (e) reference retention periods defined here ================================================================================ COMPUTER SYSTEM VALIDATION (CSV) FRAMEWORK ================================================================================ §11.10(a) requires validation but does not define the validation methodology. Industry has adopted the GAMP 5 (Good Automated Manufacturing Practice) framework published by ISPE: GAMP 5 CATEGORIES OF SOFTWARE: - Category 1: Infrastructure software (OS, databases) — minimal validation - Category 3: Non-configured software (commercial off-the-shelf, no custom configuration) — vendor assessment + testing - Category 4: Configured software (LIMS, ERP, DCS with configured workflows) — full CSV with IQ/OQ/PQ - Category 5: Custom software (bespoke applications) — full development lifecycle validation CSV LIFECYCLE DOCUMENTS FOR PART 11 COMPLIANCE: 1. Computer System Validation Master Plan (CVMP) 2. User Requirements Specification (URS) 3. Functional Requirements Specification (FRS) 4. Design Specification (DS) 5. Vendor Assessment / Supplier Qualification 6. Installation Qualification (IQ) Protocol and Report 7. Operational Qualification (OQ) Protocol and Report 8. Performance Qualification (PQ) Protocol and Report 9. Traceability Matrix 10. Summary Validation Report 11. System Release for Use (sign-off) 12. Periodic Review procedure 13. Change Control procedure CRITICAL VALIDATION REQUIREMENTS FOR PART 11 SYSTEMS: - Audit trail function specifically tested (turned on, immutable, captures all required events with correct user ID, timestamp, old/new values) - Access control tested (verify unauthorized users cannot access restricted functions) - Signature requirements tested (verify printed name, date/time, meaning appear correctly) - Signature linking tested (verify signature cannot be detached from record) - Backup and recovery tested - Data export/reporting tested (verify complete, accurate copies for FDA) ================================================================================ FDA INSPECTION READINESS FOR PART 11 ================================================================================ TYPICAL FDA INSPECTION QUESTIONS FOR PART 11: 1. "Show me your audit trail for this batch record" - Inspector will check: Is it enabled? Does it capture all required events? - Are old values captured? Is the reason for change documented? 2. "Who has administrator access to this system?" - Verifying that administrator access is limited and controlled - Checking that admin actions are also logged 3. "Can you generate a complete copy of this batch record for me?" - Testing §11.10(b) — readability and completeness of exported copies 4. "What is your process when an employee leaves the company?" - Checking timely deprovisioning under §11.10(d) 5. "Show me the validation documentation for this system" - Checking §11.10(a) — full IQ/OQ/PQ package 6. "What is your SOD [Separation of Duties] for this system?" - Checking §11.10(g) — authority checks and role separation 7. "Show me your password policy and password reset procedure" - Checking §11.300 — password management controls COMMON PART 11 FDA 483 OBSERVATIONS (REAL EXAMPLES): 1. "Audit trail was not enabled on [system name]" 2. "The system allows users to modify data without capturing the reason for change and original data" 3. "User accounts are shared between multiple personnel" 4. "The audit trail does not capture deleted records" 5. "Personnel training records for the computerized system are incomplete" 6. "No written policies holding individuals accountable for their electronic signatures" 7. "The electronic signature does not display the printed name of the signer" 8. "System administrator passwords are not periodically changed" 9. "No procedure exists for reporting lost or compromised access credentials" 10. "Backup and recovery procedures have not been tested" ================================================================================ FREQUENTLY CONFUSED CONCEPTS ================================================================================ Q: Does Part 11 require electronic records? A: NO. Part 11 only applies if a company CHOOSES to use electronic records for records that predicate rules require to be maintained. Q: Does Part 11 apply to ALL computer systems? A: NO. Only to systems that CREATE, MODIFY, MAINTAIN, ARCHIVE, RETRIEVE, or TRANSMIT records required by predicate FDA regulations. A general purpose email system used for non-regulated communications is not a Part 11 system (though if used to transmit regulated records, those records and that transmission would be subject to Part 11). Q: What is the difference between an electronic signature and a digital signature? A: Digital signatures use public key cryptography (PKI) and are a subset of electronic signatures. An electronic signature can be as simple as an ID+password combination. A digital signature is a specific cryptographic technique. Part 11 requires electronic signatures; digital signatures are required for open systems (§11.30) when additional security is needed. Q: Can you use biometrics alone (without password) for signing? A: YES. §11.200(b) states that biometric signatures must be designed to ensure only genuine owners can use them — the two-component requirement applies only to non-biometric signatures. Q: How long must audit trails be retained? A: At least as long as the associated electronic record (§11.10e). The retention period is set by the predicate rule for each record type. Q: Must FDA be notified before implementing a Part 11 system? A: Only §11.100(c) requires FDA notification — a one-time written certification that electronic signatures are intended to be legally binding. This is not a per-system notification but a company-level declaration. --- ### Document: FDA 21CFR Part312 Complete (FDA) # 21 CFR Part 312 — Investigational New Drug Applications (IND): FDA Requirements for Investigational New Drug Applications: Sponsor Obligations, CMC Requirements, and CDMO Manufacturing Responsibilities ## Section 0: Overview — IND Purpose, Exemptions & CDMO Relevance (§§ 312.1–312.10) # Section 0: Overview — IND Purpose, Exemptions & CDMO Relevance 21 CFR Part 312 — Investigational New Drug Applications (IND) | FDA | §§ 312.1–312.10 **Statutory Basis:** Section 505(i) of the Federal Food, Drug, and Cosmetic Act (FD&C Act) prohibits the interstate shipment of any drug intended for investigational use in humans unless the sponsor has an effective Investigational New Drug Application on file with FDA. This is the foundational legal hook that makes Part 312 operative. **Purpose of the IND:** The IND exists to give FDA the opportunity to review safety data and study protocols before clinical trials begin. Its twin purposes are: 1. Ensuring adequate preclinical data exists to support the proposed human studies (safety threshold), and 2. Ensuring adequate human subject protections are in place (ethical threshold). **How the IND becomes effective:** An IND is not approved by FDA — it becomes *effective* automatically **30 calendar days** after FDA receives a complete submission, unless FDA places the study on clinical hold within that window. A clinical hold is an order from FDA to delay or suspend a proposed or ongoing clinical investigation. "A sponsor may begin a clinical investigation 30 days after FDA receives the IND, or on earlier notification by FDA that the investigation may begin." — 21 CFR §312.40(b) **Two principal IND types:** - **Commercial IND:** Sponsor is a pharmaceutical or biotechnology company; the ultimate goal is submission of a New Drug Application (NDA) or Biologics License Application (BLA). Full IND with complete CMC, pharmacology, and clinical protocol sections required. - **Research (Investigator) IND:** Sponsor-investigator is typically an academic physician or institution; no commercial intent. FDA applies somewhat reduced expectations, but the IND must still meet Part 312 requirements. ## Section 1: Subpart A — IND Types, Phase Definitions & General Requirements (§§ 312.1–312.22) # Section 1: Subpart A — IND Types, Phase Definitions & General Requirements 21 CFR Part 312 — IND Applications | FDA | §§ 312.1–312.22 ### Topics Covered ## Section 2: §312.23 — IND Content: CMC Section & Manufacturing Requirements (§312.23(a)(7) — CMC section) # Section 2: §312.23 — IND Content: CMC Section & Manufacturing Requirements 21 CFR Part 312 — IND Applications | FDA | §312.23(a)(7) — CMC section ### Topics Covered ## Section 3: Subpart C — Sponsor Responsibilities: Amendments, Annual Reports & Safety Reporting (§§ 312.30–312.33) # Section 3: Subpart C — Sponsor Responsibilities: Amendments, Annual Reports & Safety Reporting 21 CFR Part 312 — IND Applications | FDA | §§ 312.30–312.33 **§ 312.30 Protocol amendments.** A sponsor shall submit a protocol amendment describing any change in a Phase 1 protocol that significantly affects the safety of subjects. A sponsor shall submit a protocol amendment describing any change in a Phase 2 or 3 protocol that significantly affects the safety of subjects, the scope of the investigation, or the scientific quality of the study. Examples of changes requiring a protocol amendment include: - Any increase in drug dosage or duration of exposure of individual research subjects beyond that in the current protocol - Any significant increase in the number of research subjects - The addition of a new test article - The addition of a new clinical investigator or research site - A significant change in the study design (e.g., adding or dropping control groups) **New Protocol Amendments** A sponsor who adds a new protocol after the IND goes into effect shall submit the new protocol to FDA as a protocol amendment. The sponsor may begin the clinical investigation on the date the amendment is submitted to FDA unless the sponsor has received a clinical hold or is conducting a Phase 1 investigation, in which case FDA's 30-day review period applies before enrollment begins. **Three Categories of Protocol Amendments** 1. **New Protocol Amendment:** Adding an entirely new clinical study (e.g., adding Phase 2 study to an existing Phase 1 IND). The new protocol must be submitted before any subjects are enrolled in the new study. 2. **Protocol Change Amendment:** Modifying an existing protocol — changing dose, duration of exposure, patient population, endpoints, or study design elements that affect subject safety or scientific quality. 3. **New Investigator Amendment:** Adding a new investigator or clinical site to the study. Must include a signed Form FDA 1572 (Statement of Investigator) and curriculum vitae. **When FDA Prior Approval (30-Day Wait) is Required:** - Any change that represents a significant increase in risk to subjects - Adding a new indication to the IND - Phase 1 protocols: sponsor must wait 30 days after submitting the protocol amendment before initiating the study, unless FDA notifies that study may proceed earlier **Notify Within 30 Days (Information Amendment):** - Minor changes that do not significantly affect subject safety, scope, or scientific quality - Administrative changes (e.g., sponsor contact information update) - Changes already reflected in other amendments submitted concurrently "A sponsor shall submit a protocol amendment describing any change in a Phase 2 or 3 protocol that significantly affects the safety of subjects, the scope of the investigation, or the scientific quality of the study." *— 21 CFR §312.30(b)* ## Section 4: Subpart D — Investigator Responsibilities, GMP Obligations & CDMO Manufacturing Controls (§§ 312.50–312.70) # Section 4: Subpart D — Investigator Responsibilities, GMP Obligations & CDMO Manufacturing Controls 21 CFR Part 312 — IND Applications | FDA | §§ 312.50–312.70 ## Regulatory Text & Analysis **§312.50 — General Sponsor Responsibilities** Sponsors are responsible for selecting qualified investigators and providing each investigator with the information needed to conduct an investigation properly, for ensuring proper monitoring of the investigation(s), for ensuring that the investigation(s) is conducted in accordance with the general investigational plan and protocols contained in the IND, for maintaining an effective IND with respect to the investigations, and for ensuring that FDA and all participating investigators are promptly informed of significant new adverse effects or risks with respect to the drug. **§312.51 — Transfer of Obligations to a Contract Research Organization (CRO)** A sponsor may transfer responsibility for any or all of the sponsor's obligations under this part to a contract research organization. Any such transfer shall be described in writing. If not all obligations are transferred, the writing is required to describe each obligation being assumed by the CRO. A CRO that assumes any obligation of a sponsor shall comply with the specific regulations applicable to that obligation and shall be subject to the same regulatory action as a sponsor for failure to comply with any obligation assumed under this part. **The sponsor retains ultimate responsibility for all transferred obligations that the CRO fails to fulfill.** **§312.52 — Use of Contract Research Organizations** If a sponsor uses a CRO, the sponsor shall transfer in writing each obligation being assumed by the CRO. The FDA may inspect the CRO to determine whether it is in compliance with the regulations applicable to the obligations assumed and whether it is performing the obligations that were transferred to it. "A contract research organization that assumes any obligation of a sponsor shall comply with the specific regulations applicable to that obligation and shall be subject to the same regulatory action as a sponsor for failure to comply." *— 21 CFR §312.52(b)* **§312.53 — Selecting Investigators and Monitors** Before permitting an investigator to begin participation in an investigation, the sponsor shall obtain the following: - A signed Form FDA 1572 — Statement of Investigator — from each investigator - A curriculum vitae or other statement of qualifications of the investigator showing the education, training, and experience that qualifies the investigator as an expert in the clinical investigation of the drug for the use under investigation - A protocol describing the clinical study to be conducted by the investigator - Financial disclosure information if required under 21 CFR Part 54 The sponsor must also select a monitor who is qualified by training and experience to monitor the progress of the investigation. --- ### Document: FDA 21CFR Part4 Complete (FDA) # 21 CFR Part 4 — Regulation of Combination Products: FDA Jurisdiction Assignment, PMOA Determination, and CGMP Dual Compliance for Combination Products ## Section 0: Overview — What Are Combination Products & Why Part 4 Matters (§4.1 + FDA guidance context) # Section 0: Overview — What Are Combination Products & Why Part 4 Matters 21 CFR Part 4 — Regulation of Combination Products | FDA | eCFR current ## What Are Combination Products? — Statutory definition, four product types, and real-world examples Regulatory Text & Summary (English) ### Statutory Definition Under **FD&C Act §3(g)** (21 U.S.C. §353(g)), the term **"combination product"** includes: - A product comprising any combination of a **drug and a device** - A product comprising a combination of a **biological product and a device** - A product comprising a combination of a **drug and a biological product** - A product comprising a combination of a **drug, device, and a biological product** The product must have two or more regulated article types working together to achieve the product's intended use. The combination may be physical, chemical, or purely functional (cross-labeling). ### Four Types of Combination Products 1. **Single-Entity Combination Product** — Two or more regulated components physically, chemically, or otherwise combined or mixed and produced as a single entity. The components cannot be separated without affecting the product's function. 2. **Co-Packaged Combination Product** — Two or more separate products packaged together in a single container or as a unit, where each component retains its own regulatory identity but is intended to be used together. 3. **Cross-Labeled Combination Product** — Two or more separate products manufactured separately, distributed separately, but labeled for use together. The labeling of one product references the other as required for safe and effective use. 4. **Investigational Combination Product** — Any of the above types when used under an Investigational New Drug (IND) application or Investigational Device Exemption (IDE). Regulatory requirements apply even in the investigational stage. ### Real-World Examples | Product | Drug Constituent | Device Constituent | Type | Lead Center | | --- | --- | --- | --- | --- | | Pre-filled syringe | Drug (liquid) | Syringe + needle | Single-entity | CDER | | Drug-eluting stent | Drug (antiproliferative) | Metal stent (primary) | Single-entity | CDRH | | mAb autoinjector pen | Biologic (mAb) | Autoinjector mechanism | Single-entity | CBER or CDER | | Antibiotic-coated surgical mesh | Antibiotic drug | Mesh (primary) | Single-entity | CDRH | | Photodynamic therapy kit | Photosensitizer drug | Light-delivery device | Co-packaged | CDER | ## Why Part 4 Was Created — Part 4 Historical context, regulatory gaps, and the creation of OCP Regulatory Text & Summary (English) ### The Problem: Three Centers, One Product Before Part 4, FDA had three separate centers with distinct regulatory standards, review timelines, and post-market requirements: - **CDER** (Center for Drug Evaluation and Research) — governed drugs under 21 CFR 210/211 - **CDRH** (Center for Devices and Radiological Health) — governed medical devices under 21 CFR 820 and the Quality System Regulation - **CBER** (Center for Biologics Evaluation and Research) — governed biologics under 21 CFR 600–680 Combination products fell into regulatory gaps where no center had clear jurisdiction, or they faced duplicative review by multiple centers. This created: - Prolonged and unpredictable review timelines - Inconsistent CGMP requirements across similar products - Manufacturer confusion about which submission pathway to use (NDA, BLA, PMA, 510(k)) - Post-market surveillance and adverse event reporting ambiguities ### Legislative Solution The **Safe Medical Devices Act of 1990** created **§3(g) of the FD&C Act**, which required FDA to: - Designate a **lead center** (primary regulatory jurisdiction) for each combination product - Base the designation on the product's **primary mode of action (PMOA)** - Ensure consistency and predictability in the designation process **21 CFR Part 4** operationalizes §3(g) by establishing the regulatory procedures for designation, including the formal **Request for Designation (RFD)** process. ### Office of Combination Products (OCP) The **Medical Device User Fee and Modernization Act (MDUFMA) of 2002** established the **Office of Combination Products (OCP)** within the FDA Commissioner's Office. OCP: - Manages the RFD process and issues binding jurisdictional determinations - Resolves inter-center disputes about jurisdiction - Develops and updates guidance on combination product regulation - Monitors combination product reviews to ensure timely, consistent decisions - Reports annually to Congress on combination product activities "The purpose of Part 4 is to achieve timely and effective premarket review of combination products and to ensure consistent and appropriate post-market regulation of these products." — 21 CFR Part 4, Preamble #### #### #### OCP #### ICA vs. Part 4 0.3 ## Why Part 4 Matters for CDMOs — Part 4 CDMO CGMP overlap, quality agreements, and the mAb autoinjector scenario Regulatory Text & Summary (English) ### Four Critical Questions for CDMO Operations A CDMO manufacturing a sterile injectable drug for a combination product must answer four questions before beginning manufacturing: 1. **Which FDA center leads regulation?** — Determines which submission type applies (NDA vs. PMA vs. BLA), which division within FDA reviews the product, and which reviewers have authority over manufacturing-related questions. 2. **Which CGMP applies — or does dual CGMP apply?** — Under 21 CFR Part 4 Subpart B (the 2013 CGMP rule), manufacturers of combination products may be subject to both 21 CFR Part 211 (drug CGMP) and 21 CFR Part 820 (Quality System Regulation for devices). The CDMO must know which applies to their specific operations. 3. **How do quality agreements allocate compliance responsibility?** — The sponsor (drug/device brand owner) and CDMO must explicitly allocate who is responsible for CGMP compliance for each constituent part. Ambiguity in quality agreements is a direct FDA 483 observation risk. 4. **When do manufacturing changes require prior approval vs. notification?** — A change to the drug formulation may require a Prior Approval Supplement (PAS), while the same change to device labeling may only require an Annual Report. The CDMO must follow the change control requirements of the lead center. ### CDMO Scenario: mAb Autoinjector Sterile Fill-Finish A CDMO performs sterile fill-finish for a monoclonal antibody (mAb) in a prefilled autoinjector pen. The product is a single-entity combination product: biologic drug (mAb) + device (autoinjector mechanism + prefilled syringe). | Question | Analysis | Implication for CDMO | | --- | --- | --- | | Lead center? | mAb is the PMOA CBER or CDER (mAbs transferred to CDER in 2003) | CDER leads; BLA is the likely submission; CMC review under CDER standards | | Which CGMP? | 21 CFR Part 4 Subpart B: both 21 CFR 211 (drug) and 21 CFR 820 (device) may apply to the combination | CDMO must document how its QMS covers both 211 and 820 requirements for the prefilled syringe/autoinjector components | | Device CGMP responsibility? | Autoinjector device constituent parts require Design History File (DHF), Device History Record (DHR) under 21 CFR 820 | Quality agreement must specify whether sponsor or CDMO maintains the DHF/DHR; CDMO must confirm its QMS is 820-compatible | | Change control? | Changes to the prefilled syringe design (e.g., new needle gauge) may require a PAS for the BLA | CDMO change control SOP must route device component changes through sponsor's BLA change management process | #### Common CDMO Trap **Assuming only drug CGMP (21 CFR 211) applies** when manufacturing the drug constituent for a combination product. Under 21 CFR Part 4 Subpart B, if the CDMO also assembles or tests device constituent parts, the quality system must also satisfy relevant provisions of 21 CFR 820. This is frequently flagged in FDA inspections of CDMOs filling combination product presentations. #### CDMO CGMP ## Relationship to Other Regulations — Cross-reference map: Part 4 Part 3 CGMP regulations; what Part 4 does NOT govern Regulatory Text & Summary (English) ### Cross-Reference Map 21 CFR Part 4 does not operate in isolation. It is part of a regulatory framework that must be read in conjunction with several other parts of the CFR: | Regulation | Title / Purpose | Relationship to Part 4 | | --- | --- | --- | **** | 21 CFR Part 3 | Product Jurisdiction — Procedures for designating the lead center | Part 4 references Part 3 for the formal RFD mechanism and jurisdictional order procedures | **** | 21 CFR Part 211 | Current Good Manufacturing Practice for Finished Pharmaceuticals | Applies to drug constituent parts; under Part 4 Subpart B, may apply to full combination product when drug CGMP is applicable | **** | 21 CFR Part 820 | Quality System Regulation (Device CGMP) | Applies to device constituent parts; under Part 4 Subpart B, may apply to combination products where device CGMP is applicable | **** | 21 CFR Parts 600–680 | Biologics Standards and CGMP | Applies to biological product constituent parts; Part 4 determines whether CBER or CDER leads biologics-containing combination products | **** | 21 CFR Part 4 Subpart B | Current Good Manufacturing Practice Requirements for Combination Products (2013) | Specifies how CGMP requirements from 211, 820, and 600s apply to combination products and how manufacturers may comply with streamlined provisions | ### What Part 4 Does NOT Govern Part 4 is frequently misunderstood as covering the entire regulatory lifecycle of combination products. It does not: - **Govern approval pathways** — NDA (21 CFR Part 314), BLA (21 CFR Part 601), PMA (21 CFR Part 814), and 510(k) (21 CFR Part 807) are governed by their respective regulations. Part 4 only determines *which center* manages those pathways. - **Establish submission formats** — The Common Technical Document (CTD) format and electronic submission requirements are set by the lead center, not Part 4. - **Define safety standards** — Biocompatibility (ISO 10993), sterility, container-closure integrity, and other technical standards are governed by USP, ISO, and center-specific guidance, not Part 4. - **Override other CFR requirements** — Part 4 operates alongside existing requirements; it does not supersede 21 CFR 211, 820, or 600. ### 21 CFR Part 4 Subpart B (2013 CGMP Rule) The most operationally significant addition to Part 4 was the 2013 final rule establishing **Subpart B: Current Good Manufacturing Practice Requirements for Combination Products**. Key provisions: - Manufacturers must comply with the CGMP requirements applicable to each constituent part - A manufacturer complying with one set of CGMP requirements (e.g., 21 CFR 820) may demonstrate compliance with certain overlapping requirements from another set (e.g., 21 CFR 211) using its own CGMP system - The rule provides a streamlined compliance pathway to reduce dual-CGMP burden while maintaining safety and quality - Applies to all combination products subject to FDA premarket review #### Part 4 **FD&C Act §3(g)** **21 CFR Part 3** **21 CFR Part 4** **21 CFR 211** **21 CFR 820** **21 CFR 600s** #### Part 4 — #### 2013 Subpart B CGMP #### — ## Section Summary — Key takeaways from Section 0 Key Takeaways (English) ### What You Should Know After This Section #### 1. Definition and Types A combination product under FD&C Act §3(g) is any product combining two or more of the following: drug, device, biological product. There are four operational types: single-entity, co-packaged, cross-labeled, and investigational. #### 2. Why Part 4 Exists Part 4 was created to resolve the pre-1990 problem of combination products falling between FDA's three separate centers (CDER, CDRH, CBER). The 1990 Safe Medical Devices Act mandated lead center designation based on primary mode of action. OCP (est. 2002) enforces this through the RFD process. #### 3. CGMP Complexity for Manufacturers Under Part 4 Subpart B (2013), combination product manufacturers may need to comply with both 21 CFR 211 and 21 CFR 820. The streamlined compliance pathway allows a single QMS to satisfy both if equivalence is documented. CDMOs must never assume only drug CGMP applies. #### 4. What Part 4 Does NOT Do Part 4 designates jurisdiction — it does not set approval pathways (NDA/BLA/PMA), technical standards, or override other CFR requirements. It is a jurisdictional and procedural rule, not a manufacturing or submission standard. #### 5. CDMO Practical Implication Before accepting any combination product contract, a CDMO must confirm: lead center designation, applicable CGMP regulations, quality agreement allocation of responsibilities, and change control routing for device constituent parts. #### 1. #### 2. Part 4 #### 3. CGMP #### 4. Part 4 #### 5. CDMO 21 CFR Part 3 (Product Jurisdiction Order procedures) | 21 CFR Part 4 §4.3 (Subpart A: Designation procedures) | 21 CFR Part 4 §4.4 (Subpart B: CGMP requirements) | 21 CFR Part 211 (Drug CGMP) | 21 CFR Part 820 (Device Quality System Regulation) | 21 CFR Parts 600–680 (Biologics) 21 CFR Part 4 — Regulation of Combination Products | FDA eCFR SterileGMP Knowledge Hub | Educational Use Only — Not Legal Advice Last Updated: 2026-04-14 ## Section 1: §4.1–4.3 — Definitions, Types & Applicable Regulations (§§ 4.1–4.3) # Section 1: §4.1–4.3 — Definitions, Types & Applicable Regulations 21 CFR Part 4 — Regulation of Combination Products | FDA | §§ 4.1–4.3 **§4.1 — Scope.** **(a)** This subpart applies to combination products as defined in §3.2(e) of this chapter. It establishes, for purposes of the Federal Food, Drug, and Cosmetic Act and the Public Health Service Act, which current good manufacturing practice (CGMP) requirements in parts 4, 210, 211, 600 through 680, and 820 of this chapter apply to combination products, and provides for the assignment of combination products to a component of FDA. **(b)** This subpart does not cover biological products that are regulated solely under the Public Health Service Act and that do not have a drug or device constituent part. **(c)** Agreements and decisions made under this part regarding which CGMP requirements apply to a specific combination product are intended to promote the efficient and timely review of applications and the timely compliance of manufacturers with applicable CGMP requirements. "This subpart applies to combination products as defined in §3.2(e) of this chapter." *— 21 CFR §4.1(a)* **Key cross-references:** - §3.2(e) — Definition of "combination product" (the operative definition) - Parts 210, 211 — Drug CGMPs (manufacturing and finished product) - Parts 600–680 — Biological product regulations - Part 820 — Device Quality System Regulation / QMSR - 21 CFR Part 3 — Product Jurisdiction (designation authority) ## Section 2: §4.5–4.9 — RFD Process, PMOA Determination & Center Assignment (§§ 4.5–4.9) # Section 2: §4.5–4.9 — RFD Process, PMOA Determination & Center Assignment 21 CFR Part 4 — Regulation of Combination Products | FDA | §§ 4.5–4.9 (+ 21 CFR Part 3 §§3.7–3.10) **§4.5 — Agreement, Determination, and Designation Procedures.** Under 21 CFR §3.4 and §4.5, a manufacturer or sponsor seeking to determine which FDA center has primary jurisdiction over a combination product has three procedural options: **Option 1 — Informal OCP Consultation (Non-binding)** A sponsor may contact OCP informally to discuss product classification questions. OCP staff will provide informal guidance based on precedent products and existing regulatory determinations. This path is fastest and costs no application time, but the response is not a formal designation and does not bind FDA. **Option 2 — Pre-RFD Meeting** Before filing a formal RFD, a sponsor may request a pre-RFD meeting with OCP to discuss the product's constituent parts, proposed PMOA, and likely center assignment. This meeting clarifies whether a formal RFD is warranted and helps the sponsor prepare a stronger submission. Pre-RFD meetings are especially useful when the PMOA is scientifically ambiguous. **Option 3 — Formal Request for Designation (RFD)** A sponsor files a written RFD with OCP under §3.7. FDA must respond within 60 calendar days. The designation issued is binding on FDA and establishes the lead center for the product's lifecycle. Filing an RFD is strongly recommended before submitting the first marketing application (IND, NDA, BLA, or PMA). **When to file formal RFD vs. proceed directly:** - File formal RFD when: PMOA is unclear; no clear precedent product exists; the product spans two or more center jurisdictions; sponsor needs binding confirmation for regulatory strategy - Proceed directly to lead center when: prior OCP informal guidance is consistent; the product is nearly identical to a previously designated combination product; the primary constituent part classification is unambiguous ## Section 3: §4.10–4.11 — CGMP Dual Compliance, Post-Market Obligations & CDMO Responsibilities (§§ 4.10–4.11) # Section 3: §4.10–4.11 — CGMP Dual Compliance, Post-Market Obligations & CDMO Responsibilities 21 CFR Part 4 — Regulation of Combination Products | FDA | §§ 4.10–4.11 ## Regulatory Framework **§ 4.4 Current good manufacturing practice requirements.** 21 CFR Part 4 Subpart B establishes CGMP requirements for combination products. The 2013 Final Rule (effective December 22, 2013) clarified how manufacturers demonstrate compliance when a combination product includes both drug and device constituents. ### §4.4(a) — Default Dual Compliance Rule The default rule is straightforward: a combination product must comply with the CGMP regulations applicable to *each* constituent part. - If the combination product includes a **drug constituent part** must comply with 21 CFR Parts 210 and 211 (drug CGMP) - If the combination product includes a **device constituent part** must comply with 21 CFR Part 820 (Quality System Regulation / QSR) - If the combination product includes a **biological product constituent part** must also comply with 21 CFR Parts 600–680 - If a combination product includes all three types all three sets of CGMP requirements apply ### §4.4(b) — The Streamlined Approach The streamlined approach is the practical pathway for most manufacturers. Under §4.4(b), a manufacturer may comply with *only one* set of CGMP regulations — either Part 211 or Part 820 as the primary framework — provided the manufacturer demonstrates that the **controls established under the primary CGMP framework satisfy the requirements** of the other applicable CGMP regulation. Key operational requirement: The manufacturer must **document how** each applicable requirement from the non-primary CGMP set is satisfied by the primary system. This documentation is the gap analysis crosswalk — FDA will review it during inspection. ### §4.4(b) — What "Streamlined" Does NOT Mean Critically, "streamlined" does not mean the manufacturer can ignore requirements that exist only in one regulation and not the other. If a requirement is unique to one regulation with no functional equivalent in the other, that unique requirement must still be implemented. The streamlined approach only allows avoiding literal duplication of procedures when the same outcome is already achieved through an existing system. "A person who manufactures or processes a combination product may satisfy the current good manufacturing practice requirements applicable to the combination product by complying with either the drug current good manufacturing practice regulations in parts 210 and 211 of this chapter or the device quality system regulation in part 820 of this chapter, provided the person demonstrates that compliance with that regulation satisfies the requirements of the other applicable regulation(s)." *— 21 CFR §4.4(b), the streamlined compliance option* ### 2013 Final Rule — FDA's Operational Guidance The 2013 Final Rule clarified several key implementation questions: - FDA confirmed that the lead center's CGMP framework should typically serve as the **primary** CGMP system - The crosswalk documentation does not need to be a separate standalone document — it may be embedded in SOPs, quality agreements, or the Quality Manual - FDA's "Guidance for Industry and FDA Staff: Current Good Manufacturing Practice Requirements for Combination Products" (January 2017) provides detailed guidance on implementing the streamlined approach - FDA confirmed that both CDRH and CDER/CBER may conduct inspections of a single site manufacturing combination products --- ### Document: FDA Aseptic Complete (FDA) # FDA Guidance for Industry: Sterile Drug Products by Aseptic Processing — CGMP (2004) --- PAGE 1 --- Guidance for Industry Sterile Drug Products Produced by Aseptic Processing — Current Good Manufacturing Practice U.S. Department of Health and Human Services Food and Drug Administration Center for Drug Evaluation and Research (CDER) Center for Biologics Evaluation and Research (CBER) Office of Regulatory Affairs (ORA) September 2004 Pharmaceutical CGMPs --- PAGE 2 --- Guidance for Industry Sterile Drug Products Produced by Aseptic Processing — Current Good Manufacturing Practice Additional copies are available from: Office of Training and Communication Division of Drug Information, HFD-240 Center for Drug Evaluation and Research Food and Drug Administration 5600 Fishers Lane (Tel) 301-827-4573 http://www.fda.gov/cder/guidance/index.htm or Office of Communication, Training and Manufacturers Assistance, HFM-40 Center for Biologics Evaluation and Research Food and Drug Administration 1401 Rockville Pike, Rockville, MD 20852-1448 http://www.fda.gov/cber/guidelines.htm. (Tel) Voice Information System at 800-835-4709 or 301-827-1800 U.S. Department of Health and Human Services Food and Drug Administration Center for Drug Evaluation and Research (CDER) Center for Biologics Evaluation and Research (CBER) Office of Regulatory affairs (ORA) September 2004 Pharmaceutical CGMPs --- PAGE 3 --- Contains Nonbinding Recommendations TABLE OF CONTENTS I. INTRODUCTION............................................................................................................. 1 II. BACKGROUND ............................................................................................................... 2 A. Regulatory Framework .................................................................................................................2 B. Technical Framework....................................................................................................................2 III. SCOPE ............................................................................................................................... 3 IV. BUILDINGS AND FACILITIES .................................................................................... 4 A. Critical Area – Class 100 (ISO 5) .................................................................................................5 B. Supporting Clean Areas ................................................................................................................7 C. Clean Area Separation ..................................................................................................................7 D. Air Filtration ..................................................................................................................................8 1. Membrane ........................................................................................................................................8 2. High-Efficiency Particulate Air (HEPA) .........................................................................................8 E. Design............................................................................................................................................10 V. PERSONNEL TRAINING, QUALIFICATION, & MONITORING........................ 12 A. Personnel.......................................................................................................................................13 B. Laboratory Personnel..................................................................................................................15 C. Monitoring Program....................................................................................................................15 VI. COMPONENTS AND CONTAINER/CLOSURES.......................................................... 15 A. Components..................................................................................................................................16 B. Containers/Closures.....................................................................................................................17 1. Preparation....................................................................................................................................17 2. Inspection of Container Closure System........................................................................................18 VII. ENDOTOXIN CONTROL................................................................................................. 19 VIII. TIME LIMITATIONS...................................................................................................... 20 IX. VALIDATION OF ASEPTIC PROCESSING AND STERILIZATION.................. 20 A. Process Simulations .....................................................................................................................20 1. Study Design .................................................................................................................................21 2. Frequency and Number of Runs ....................................................................................................22 3. Duration of Runs............................................................................................................................22 4. Size of Runs....................................................................................................................................23 5. Line Speed......................................................................................................................................23 6. Environmental Conditions .............................................................................................................24 7. Media ............................................................................................................................................24 8. Incubation and Examination of Media-Filled Units......................................................................24 9. Interpretation of Test Results.........................................................................................................26 B. Filtration Efficacy........................................................................................................................27 --- PAGE 4 --- Contains Nonbinding Recommendations C. Sterilization of Equipment, Containers, and Closures .............................................................28 1. Qualification and Validation .........................................................................................................29 2. Equipment Controls and Instrument Calibration ..........................................................................30 X. LABORATORY CONTROLS ...................................................................................... 31 A. Environmental Monitoring .........................................................................................................32 1. General Written Program.............................................................................................................32 2. Establishing Levels and a Trending Program ...............................................................................33 3. Disinfection Efficacy......................................................................................................................34 4. Monitoring Methods......................................................................................................................34 B. Microbiological Media and Identification .................................................................................35 C. Prefiltration Bioburden...............................................................................................................36 D. Alternate Microbiological Test Methods ...................................................................................36 E. Particle Monitoring......................................................................................................................36 XI. STERILITY TESTING.................................................................................................. 37 A. Microbiological Laboratory Controls........................................................................................38 B. Sampling and Incubation ............................................................................................................38 C. Investigation of Sterility Positives ..............................................................................................39 XII. BATCH RECORD REVIEW: PROCESS CONTROL DOCUMENTATION ........ 42 APPENDIX 1: ASEPTIC PROCESSING ISOLATORS....................................................... 44 APPENDIX 2: BLOW-FILL- SEAL TECHNOLOGY.......................................................... 49 APPENDIX 3: PROCESSING PRIOR TO FILLING AND SEALING OPERATIONS.... 52 REFERENCES............................................................................................................................ 54 RELEVANT GUIDANCE DOCUMENTS............................................................................... 55 GLOSSARY................................................................................................................................. 56 --- PAGE 5 --- Contains Nonbinding Recommendations Guidance for Industry1 Sterile Drug Products Produced by Aseptic Processing — Current Good Manufacturing Practice This guidance represents the Food and Drug Administration's (FDA's) current thinking on this topic. It does not create or confer any rights for or on any person and does not operate to bind FDA or the public. You can use an alternative approach if the approach satisfies the requirements of the applicable statutes and regulations. If you want to discuss an alternative approach, contact the FDA staff responsible for implementing this guidance. If you cannot identify the appropriate FDA staff, call the appropriate number listed on the title page of this guidance. I. INTRODUCTION This guidance is intended to help manufacturers meet the requirements in the Agency's current good manufacturing practice (CGMP) regulations (2l CFR parts 210 and 211) when manufacturing sterile drug and biological products using aseptic processing. This guidance replaces the 1987 Industry Guideline on Sterile Drug Products Produced by Aseptic Processing (Aseptic Processing Guideline). This revision updates and clarifies the 1987 guidance. For sterile drug products subject to a new or abbreviated drug application (NDA or ANDA) or a biologic license application (BLA), this guidance document should be read in conjunction with the guidance on the content of sterile drug applications entitled Guideline for the Submission of Documentation for Sterilization Process Validation in Applications for Human and Veterinary Drug Products (Submission Guidance). The Submission Guidance describes the types of information and data that should be included in drug applications to demonstrate the efficacy of a manufacturer's sterilization process. This guidance compliments the Submission Guidance by describing procedures and practices that will help enable a sterile drug manufacturing facility to meet CGMP requirements relating, for example, to facility design, equipment suitability, process validation, and quality control. FDA's guidance documents, including this guidance, do not establish legally enforceable responsibilities. Instead, guidances describe the Agency's current thinking on a topic and should be viewed only as recommendations, unless specific regulatory or statutory requirements are cited. The use of the word should in Agency guidances means that something is suggested or recommended, but not required. 1 This guidance was developed by the Office of Compliance in the Center for Drug Evaluation and Research (CDER) in cooperation with the Center for Biologics Evaluation and Research (CBER) and the Office of Regulatory Affairs (ORA). --- PAGE 6 --- Contains Nonbinding Recommendations The text boxes included in this guidance include specific sections of parts 210 and 211 of the Code of Federal Regulations (CFR), which address current good manufacturing practice for drugs. The intent of including these quotes in the text boxes is to aid the reader by providing a portion of an applicable regulation being addressed in the guidance. The quotes included in the text boxes are not intended to be exhaustive. Readers of this document should reference the complete CFR to ensure that they have complied, in full, with all relevant sections of the regulations. II. BACKGROUND This section describes briefly both the regulatory and technical reasons why the Agency is developing this guidance document. A. Regulatory Framework This guidance pertains to current good manufacturing practice (CGMP) regulations (21 CFR parts 210 and 211) when manufacturing sterile drug and biological products using aseptic processing. Although the focus of this guidance is on CGMPs in 21 CFR 210 and 211, supplementary requirements for biological products are in 21 CFR 600-680. For biological products regulated under 21 CFR parts 600 through 680, §§ 210.2(a) and 211.1(b) provide that where it is impossible to comply with the applicable regulations in both parts 600 through 680 and parts 210 and 211, the regulation specifically applicable to the drug product in question shall supercede the more general regulations. B. Technical Framework There are basic differences between the production of sterile drug products using aseptic processing and production using terminal sterilization. Terminal sterilization usually involves filling and sealing product containers under high-quality environmental conditions. Products are filled and sealed in this type of environment to minimize the microbial and particulate content of the in-process product and to help ensure that the subsequent sterilization process is successful. In most cases, the product, container, and closure have low bioburden, but they are not sterile. The product in its final container is then subjected to a sterilization process such as heat or irradiation. In an aseptic process, the drug product, container, and closure are first subjected to sterilization methods separately, as appropriate, and then brought together.2 Because there is no process to sterilize the product in its final container, it is critical that containers be filled and sealed in an extremely high-quality environment. Aseptic processing involves more variables than terminal sterilization. Before aseptic assembly into a final product, the individual parts of the final product 2 Due to their nature, certain products are aseptically processed at an earlier stage in the process, or in their entirety. Cellular therapy products are an example. All components and excipients for these products are rendered sterile, and release of the final product is contingent on determination of sterility. See Appendix III. --- PAGE 7 --- Contains Nonbinding Recommendations are generally subjected to various sterilization processes. For example, glass containers are subjected to dry heat; rubber closures are subjected to moist heat; and liquid dosage forms are subjected to filtration. Each of these manufacturing processes requires validation and control. Each process could introduce an error that ultimately could lead to the distribution of a contaminated product. Any manual or mechanical manipulation of the sterilized drug, components, containers, or closures prior to or during aseptic assembly poses the risk of contamination and thus necessitates careful control. A terminally sterilized drug product, on the other hand, undergoes final sterilization in a sealed container, thus limiting the possibility of error.3 Sterile drug manufacturers should have a keen awareness of the public health implications of distributing a nonsterile product. Poor CGMP conditions at a manufacturing facility can ultimately pose a life-threatening health risk to a patient. III. SCOPE This guidance document discusses selected issues and does not address all aspects of aseptic processing. For example, the guidance addresses primarily finished drug product CGMP issues while only limited information is provided regarding upstream bulk processing steps. This guidance updates the 1987 Aseptic Processing Guideline primarily with respect to personnel qualification, cleanroom design, process design, quality control, environmental monitoring, and review of production records. The use of isolators for aseptic processing is also discussed. Although this guidance document discusses CGMP issues relating to the sterilization of components, containers, and closures, terminal sterilization of drug products is not addressed. It is a well-accepted principle that sterile drugs should be manufactured using aseptic processing only when terminal sterilization is not feasible. However, some final packaging may afford some unique and substantial advantage (e.g., some dual-chamber syringes) that would not be possible if terminal sterilization were employed. In such cases, a manufacturer can explore the option of adding adjunct processing steps to increase the level of sterility assurance. A list of references that may be of value to the reader is included at the conclusion of this document. 3 Nearly all drugs recalled due to nonsterility or lack of sterility assurance in the period spanning 1980-2000 were produced via aseptic processing. --- PAGE 8 --- Contains Nonbinding Recommendations IV. BUILDINGS AND FACILITIES 21 CFR 211.42(b) states, in part, that “The flow of components, drug product containers, closures, labeling, in-process materials, and drug products through the building or buildings shall be designed to prevent contamination.” 21 CFR 211.42(c) states, in part, that “Operations shall be performed within specifically defined areas of adequate size. There shall be separate or defined areas or such other control systems for the firm’s operations as are necessary to prevent contamination or mixups during the course of the following procedures: * * * (10) Aseptic processing, which includes as appropriate: (i) Floors, walls, and ceilings of smooth, hard surfaces that are easily cleanable; (ii) Temperature and humidity controls; (iii) An air supply filtered through high-efficiency particulate air filters under positive pressure, regardless of whether flow is laminar or nonlaminar; (iv) A system for monitoring environmental conditions; (v) A system for cleaning and disinfecting the room and equipment to produce aseptic conditions; (vi) A system for maintaining any equipment used to control the aseptic conditions.” 21 CFR 211.46(b) states that “Equipment for adequate control over air pressure, micro-organisms, dust, humidity, and temperature shall be provided when appropriate for the manufacture, processing, packing, or holding of a drug product.” 21 CFR 211.46(c) states, in part, that “Air filtration systems, including prefilters and particulate matter air filters, shall be used when appropriate on air supplies to production areas * * *.” 21 CFR 211.63 states that “Equipment used in the manufacture, processing, packing, or holding of a drug product shall be of appropriate design, adequate size, and suitably located to facilitate operations for its intended use and for its cleaning and maintenance.” 21 CFR 211.65(a) states that “Equipment shall be constructed so that surfaces that contact components, in- process materials, or drug products shall not be reactive, additive, or absorptive so as to alter the safety, identity, strength, quality, or purity of the drug product beyond the official or other established requirements.” 21 CFR 211.67(a) states that “Equipment and utensils shall be cleaned, maintained, and sanitized at appropriate intervals to prevent malfunctions or contamination that would alter the safety, identity, strength, quality, or purity of the drug product beyond the official or other established requirements.” 21 CFR 211.113(b) states that “Appropriate written procedures, designed to prevent microbiological contamination of drug products purporting to be sterile, shall be established and followed. Such procedures shall include validation of any sterilization process.” As provided for in the regulations, separate or defined areas of operation in an aseptic processing facility should be appropriately controlled to attain different degrees of air quality depending on the nature of the operation. Design of a given area involves satisfying microbiological and particle criteria as defined by the equipment, components, and products exposed, as well as the operational activities conducted in the area. --- PAGE 9 --- Contains Nonbinding Recommendations Clean area control parameters should be supported by microbiological and particle data obtained during qualification studies. Initial cleanroom qualification includes, in part, an assessment of air quality under as-built, static conditions. It is important for area qualification and classification to place most emphasis on data generated under dynamic conditions (i.e., with personnel present, equipment in place, and operations ongoing). An adequate aseptic processing facility monitoring program also will assess conformance with specified clean area classifications under dynamic conditions on a routine basis. The following table summarizes clean area air classifications and recommended action levels of microbiological quality (Ref. 1). TABLE 1- Air Classificationsa Clean Area Classification (0.5 um particles/ft3) ISO Designationb > 0.5 µm particles/m3 Microbiological Active Air Action Levelsc (cfu/m3 ) Microbiological Settling Plates Action Levelsc,d (diam. 90mm; cfu/4 hours) 3,520 1e 1e 1000 35,200 10,000 352,000 100,000 3,520,000 a- All classifications based on data measured in the vicinity of exposed materials/articles during periods of activity. b- ISO 14644-1 designations provide uniform particle concentration values for cleanrooms in multiple industries. An ISO 5 particle concentration is equal to Class 100 and approximately equals EU Grade A. c- Values represent recommended levels of environmental quality. You may find it appropriate to establish alternate microbiological action levels due to the nature of the operation or method of analysis. d- The additional use of settling plates is optional. e- Samples from Class 100 (ISO 5) environments should normally yield no microbiological contaminants. Two clean areas are of particular importance to sterile drug product quality: the critical area and the supporting clean areas associated with it. A. Critical Area – Class 100 (ISO 5) A critical area is one in which the sterilized drug product, containers, and closures are exposed to environmental conditions that must be designed to maintain product sterility (§ 211.42(c)(10)). Activities conducted in such areas include manipulations (e.g., aseptic connections, sterile ingredient additions) of sterile materials prior to and during filling and closing operations. This area is critical because an exposed product is vulnerable to contamination and will not be subsequently sterilized in its immediate container. To maintain product sterility, it is essential that the environment in which aseptic operations (e.g., equipment setup, filling) are conducted be controlled and maintained at an appropriate quality. One aspect of environmental quality is the particle content of the air. Particles are significant because they can enter a product as an extraneous contaminant, and can also contaminate it biologically by acting as a vehicle for microorganisms (Ref. 2). Appropriately designed air handling systems minimize particle content of a critical area. Air in the immediate proximity of exposed sterilized containers/closures and filling/closing operations would be of appropriate particle quality when it has a per-cubic-meter particle count --- PAGE 10 --- Contains Nonbinding Recommendations of no more than 3520 in a size range of 0.5 µm and larger when counted at representative locations normally not more than 1 foot away from the work site, within the airflow, and during filling/closing operations. This level of air cleanliness is also known as Class 100 (ISO 5). We recommend that measurements to confirm air cleanliness in critical areas be taken at sites where there is most potential risk to the exposed sterilized product, containers, and closures. The particle counting probe should be placed in an orientation demonstrated to obtain a meaningful sample. Regular monitoring should be performed during each production shift. We recommend conducting nonviable particle monitoring with a remote counting system. These systems are capable of collecting more comprehensive data and are generally less invasive than portable particle counters. See Section X.E. for additional guidance on particle monitoring. Some operations can generate high levels of product (e.g., powder) particles that, by their nature, do not pose a risk of product contamination. It may not, in these cases, be feasible to measure air quality within the one-foot distance and still differentiate background levels of particles from air contaminants. In these instances, air can be sampled in a manner that, to the extent possible, characterizes the true level of extrinsic particle contamination to which the product is exposed. Initial qualification of the area under dynamic conditions without the actual filling function provides some baseline information on the non-product particle generation of the operation. HEPA-filtered4 air should be supplied in critical areas at a velocity sufficient to sweep particles away from the filling/closing area and maintain unidirectional airflow during operations. The velocity parameters established for each processing line should be justified and appropriate to maintain unidirectional airflow and air quality under dynamic conditions within the critical area (Ref. 3).5 Proper design and control prevents turbulence and stagnant air in the critical area. Once relevant parameters are established, it is crucial that airflow patterns be evaluated for turbulence or eddy currents that can act as a channel or reservoir for air contaminants (e.g., from an adjoining lower classified area). In situ air pattern analysis should be conducted at the critical area to demonstrate unidirectional airflow and sweeping action over and away from the product under dynamic conditions. The studies should be well documented with written conclusions, and include evaluation of the impact of aseptic manipulations (e.g., interventions) and equipment design. Videotape or other recording mechanisms have been found to be useful aides in assessing airflow initially as well as facilitating evaluation of subsequent equipment configuration changes. It is important to note that even successfully qualified systems can be compromised by poor operational, maintenance, or personnel practices. Air monitoring samples of critical areas should normally yield no microbiological contaminants. We recommend affording appropriate investigative attention to contamination occurrences in this environment. 4High Efficiency Particulate Air filter 5 A velocity of 0.45 meters/second (90 feet per minute) has generally been established, with a range of plus or minus 20 percent around the setpoint. Higher velocities may be appropriate in operations generating high levels of particulates. --- PAGE 11 --- Contains Nonbinding Recommendations B. Supporting Clean Areas Supporting clean areas can have various classifications and functions. Many support areas function as zones in which nonsterile components, formulated products, in-process materials, equipment, and container/closures are prepared, held, or transferred. These environments are soundly designed when they minimize the level of particle contaminants in the final product and control the microbiological content (bioburden) of articles and components that are subsequently sterilized. The nature of the activities conducted in a supporting clean area determines its classification. FDA recommends that the area immediately adjacent to the aseptic processing line meet, at a minimum, Class 10,000 (ISO 7) standards (see Table 1) under dynamic conditions. Manufacturers can also classify this area as Class 1,000 (ISO 6) or maintain the entire aseptic filling room at Class 100 (ISO 5). An area classified at a Class 100,000 (ISO 8) air cleanliness level is appropriate for less critical activities (e.g., equipment cleaning). C. Clean Area Separation An essential part of contamination prevention is the adequate separation of areas of operation. To maintain air quality, it is important to achieve a proper airflow from areas of higher cleanliness to adjacent less clean areas. It is vital for rooms of higher air cleanliness to have a substantial positive pressure differential relative to adjacent rooms of lower air cleanliness. For example, a positive pressure differential of at least 10-15 Pascals (Pa)6 should be maintained between adjacent rooms of differing classification (with doors closed). When doors are open, outward airflow should be sufficient to minimize ingress of contamination, and it is critical that the time a door can remain ajar be strictly controlled (Ref. 4). In some cases, the aseptic processing room and adjacent cleanrooms have the same classification. Maintaining a pressure differential (with doors closed) between the aseptic processing room and these adjacent rooms can provide beneficial separation. In any facility designed with an unclassified room adjacent to the aseptic processing room, a substantial overpressure (e.g., at least 12.5 Pa) from the aseptic processing room should be maintained at all times to prevent contamination. If this pressure differential drops below the minimum limit, it is important that the environmental quality of the aseptic processing room be restored and confirmed. The Agency recommends that pressure differentials between cleanrooms be monitored continuously throughout each shift and frequently recorded. All alarms should be documented and deviations from established limits should be investigated. Air change rate is another important cleanroom design parameter. For Class 100,000 (ISO 8) supporting rooms, airflow sufficient to achieve at least 20 air changes per hour is typically acceptable. Significantly higher air change rates are normally needed for Class 10,000 and Class 100 areas. 6 Equal to 0.04-0.06 inches of water gauge. --- PAGE 12 --- Contains Nonbinding Recommendations A suitable facility monitoring system will rapidly detect atypical changes that can compromise the facility’s environment. An effective system facilitates restoration of operating conditions to established, qualified levels before reaching action levels. For example, pressure differential specifications should enable prompt detection (i.e., alarms) of an emerging low pressure problem to preclude ingress of unclassified air into a classified room. D. Air Filtration 1. Membrane A compressed gas should be of appropriate purity (e.g., free from oil) and its microbiological and particle quality after filtration should be equal to or better than that of the air in the environment into which the gas is introduced. Compressed gases such as air, nitrogen, and carbon dioxide are often used in cleanrooms and are frequently employed in purging or overlaying. Membrane filters can be used to filter a compressed gas to meet an appropriate high-quality standard. These filters are often used to produce a sterile compressed gas to conduct operations involving sterile materials, such as components and equipment. For example, we recommend that sterile membrane filters be used for autoclave air lines, lyophilizer vacuum breaks, and tanks containing sterilized materials. Sterilized holding tanks and any contained liquids should be held under positive pressure or appropriately sealed to prevent microbial contamination. Safeguards should be in place to prevent a pressure change that can result in contamination due to back flow of nonsterile air or liquid. Gas filters (including vent filters) should be dry. Condensate on a gas filter can cause blockage during use or allow for the growth of microorganisms. Use of hydrophobic filters, as well as application of heat to these filters where appropriate, prevents problematic moisture residues. We recommend that filters that serve as sterile boundaries or supply sterile gases that can affect product be integrity tested upon installation and periodically thereafter (e.g., end of use). Integrity tests are also recommended after activities that may damage the filter. Integrity test failures should be investigated, and filters should be replaced at appropriate, defined intervals. 2. High-Efficiency Particulate Air (HEPA)7 HEPA filter integrity should be maintained to ensure aseptic conditions. Leak testing should be performed at installation to detect integrity breaches around the sealing gaskets, through the frames, or through various points on the filter media. Thereafter, leak tests should be performed at suitable time intervals for HEPA filters in the aseptic processing facility. For example, such testing should be performed twice a year for the aseptic processing room. Additional testing may be appropriate when air quality is found to be unacceptable, facility renovations might be the cause of disturbances to ceiling or wall structures, or as part of an investigation into a media fill or drug product sterility failure. Among the filters that should be leak tested are those installed in dry heat depyrogenation tunnels and ovens commonly used to depyrogenate glass vials. Where justified, alternate methods can be used to test HEPA filters in the hot zones of these tunnels and ovens. 7 The same broad principles can be applied to ULPA filters. --- PAGE 13 --- Contains Nonbinding Recommendations Any aerosol used for challenging a HEPA filter should meet specifications for critical physicochemical attributes such as viscosity. Dioctylphthalate (DOP) and poly-alpha-olefin (PAO) are examples of appropriate leak testing aerosols. Some aerosols are problematic because they pose the risk of microbial contamination of the environment being tested. Accordingly, the evaluation of any alternative aerosol involves ensuring it does not promote microbial growth. There is a major difference between filter leak testing and efficiency testing. An efficiency test is a general test used to determine the rating of the filter.8 An intact HEPA filter should be capable of retaining at least 99.97 percent of particulates greater than 0.3 µm in diameter. The purpose of performing regularly scheduled leak tests, on the other hand, is to detect leaks from the filter media, filter frame, or seal. The challenge involves use of a polydispersed aerosol usually composed of particles with a light-scattering mean droplet diameter in the submicron size range,9 including a sufficient number of particles at approximately 0.3 µm. Performing a leak test without introducing a sufficient upstream challenge of particles of known size upstream of the filter is ineffective for detecting leaks. It is important to introduce an aerosol upstream of the filter in a concentration that is appropriate for the accuracy of the aerosol photometer. The leak test should be done in place, and the filter face scanned on the downstream side with an appropriate photometer probe, at a sampling rate of at least one cubic foot per minute. The downstream leakage measured by the probe should then be calculated as a percent of the upstream challenge. An appropriate scan should be conducted on the entire filter face and frame, at a position about one to two inches from the face of the filter. This comprehensive scanning of HEPA filters should be fully documented. A single probe reading equivalent to 0.01 percent of the upstream challenge would be considered as indicative of a significant leak and calls for replacement of the HEPA filter or, when appropriate, repair in a limited area. A subsequent confirmatory retest should be performed in the area of any repair. HEPA filter leak testing alone is insufficient to monitor filter performance. It is important to conduct periodic monitoring of filter attributes such as uniformity of velocity across the filter (and relative to adjacent filters). Variations in velocity can cause turbulence that increases the possibility of contamination. Velocities of unidirectional air should be measured 6 inches from the filter face and at a defined distance proximal to the work surface for HEPA filters in the critical area. Velocity monitoring at suitable intervals can provide useful data on the critical area in which aseptic processing is performed. The measurements should correlate to the velocity range established at the time of in situ air pattern analysis studies. HEPA filters should be replaced when nonuniformity of air velocity across an area of the filter is detected or airflow patterns may be adversely affected. 8 The efficiency test uses a monodispersed aerosol of 0.3 micron sized particles and assesses filter media. Downstream readings represent an average over the entire filter surface. Efficiency tests are not intended to test for filter leaks. 9 Although the mean is normally less than one micron, it is greater than 0.3µm. --- PAGE 14 --- Contains Nonbinding Recommendations Although contractors often provide these services, drug manufacturers are responsible for ensuring that equipment specifications, test methods, and acceptance criteria are defined, and that these essential certification activities are conducted satisfactorily. E. Design Note: The design concepts discussed within this section are not intended to be exhaustive. Other appropriate technologies that achieve increased sterility assurance are also encouraged. Aseptic processes are designed to minimize exposure of sterile articles to the potential contamination hazards of the manufacturing operation. Limiting the duration of exposure of sterile product elements, providing the highest possible environmental control, optimizing process flow, and designing equipment to prevent entrainment of lower quality air into the Class 100 (ISO 5) clean area are essential to achieving high assurance of sterility (Ref. 4). Both personnel and material flow should be optimized to prevent unnecessary activities that could increase the potential for introducing contaminants to exposed product, container-closures, or the surrounding environment. The layout of equipment should provide for ergonomics that optimize comfort and movement of operators. The number of personnel in an aseptic processing room should be minimized. The flow of personnel should be designed to limit the frequency with which entries and exits are made to and from an aseptic processing room and, most significant, its critical area. Regarding the latter, the number of transfers into the critical area of a traditional cleanroom, or an isolator, should be minimized. To prevent changes in air currents that introduce lower quality air, movement adjacent to the critical area should be appropriately restricted. Any intervention or stoppage during an aseptic process can increase the risk of contamination. The design of equipment used in aseptic processing should limit the number and complexity of aseptic interventions by personnel. For example, personnel intervention can be reduced by integrating an on-line weight check device, thus eliminating a repeated manual activity within the critical area. Rather than performing an aseptic connection, sterilizing the preassembled connection using sterilize-in-place (SIP) technology also can eliminate a significant aseptic manipulation. Automation of other process steps, including the use of technologies such as robotics, can further reduce risk to the product. Products should be transferred under appropriate cleanroom conditions. For example, lyophilization processes include transfer of aseptically filled product in partially sealed containers. To prevent contamination, a partially closed sterile product should be transferred only in critical areas.10 Facility design should ensure that the area between a filling line and the lyophilizer provide for Class 100 (ISO 5) protection. Transport and loading procedures should afford the same protection. The sterile drug product and its container-closures should be protected by equipment of suitable design. Carefully designed curtains and rigid plastic shields are among the barriers that can be 10 Appropriately designed transfer equipment provides these conditions and can be qualified for this purpose. --- PAGE 15 --- Contains Nonbinding Recommendations used in appropriate locations to achieve segregation of the aseptic processing line. Use of an isolator system further enhances product protection (see Appendix 1). Due to the interdependence of the various rooms that make up an aseptic processing facility, it is essential to carefully define and control the dynamic interactions permitted between cleanrooms. Use of a double-door or integrated sterilizer helps ensure direct product flow, often from a lower to a higher classified area. Airlocks and interlocking doors will facilitate better control of air balance throughout the aseptic processing facility. Airlocks should be installed between the aseptic manufacturing area entrance and the adjoining unclassified area. Other interfaces such as personnel transitions or material staging areas are appropriate locations for air locks. It is critical to adequately control material (e.g., in-process supplies, equipment, utensils) as it transfers from lesser to higher classified clean areas to prevent the influx of contaminants. For example, written procedures should address how materials are to be introduced into the aseptic processing room to ensure that room conditions remain uncompromised. In this regard, materials should be disinfected according to appropriate procedures or, when used in critical areas, rendered sterile by a suitable method. If stoppered vials exit an aseptic processing zone or room prior to capping, appropriate assurances should be in place to safeguard the product, such as local protection until completion of the crimping step. Use of devices for on-line detection of improperly seated stoppers can provide additional assurance. Cleanrooms are normally designed as functional units with specific purposes. The materials of construction of cleanrooms ensure ease of cleaning and sanitizing. Examples of adequate design features include seamless and rounded floor to wall junctions as well as readily accessible corners. Floors, walls, and ceilings should be constructed of smooth, hard surfaces that can be easily cleaned. Ceilings and associated HEPA filter banks should be designed to protect sterile materials from contamination. Cleanrooms also should not contain unnecessary equipment, fixtures, or materials. Processing equipment and systems should be equipped with sanitary fittings and valves. With rare exceptions, drains are considered inappropriate for classified areas of the aseptic processing facility other than Class 100,000 (ISO 8) areas. It is essential that any drain installed in an aseptic processing facility be of suitable design. Equipment should be appropriately designed (§ 211.63) to facilitate ease of sterilization. It is also important to ensure ease of installation to facilitate aseptic setup. The effect of equipment design on the cleanroom environment should be addressed. Horizontal surfaces or ledges that accumulate particles should be avoided. Equipment should not obstruct airflow and, in critical areas, its design should not disturb unidirectional airflow. Deviation or change control systems should address atypical conditions posed by shutdown of air handling systems or other utilities, and the impact of construction activities on facility control. Written procedures should address returning a facility to operating conditions following a shutdown. --- PAGE 16 --- Contains Nonbinding Recommendations V. PERSONNEL TRAINING, QUALIFICATION, & MONITORING 21 CFR 211.22(a) states that “There shall be a quality control unit that shall have the responsibility and authority to approve or reject all components, drug product containers, closures, in-process materials, packaging material, labeling, and drug products, and the authority to review production records to assure that no errors have occurred or, if errors have occurred, that they have been fully investigated. The quality control unit shall be responsible for approving or rejecting drug products manufactured, processed, packed, or held under contract by another company.” 21 CFR 211.22(c) states that “The quality control unit shall have the responsibility for approving or rejecting all procedures or specifications impacting on the identity, strength, quality, and purity of the drug product.” 21 CFR 211.25(a) states that “Each person engaged in the manufacture, processing, packing, or holding of a drug product shall have education, training, and experience, or any combination thereof, to enable that person to perform the assigned functions. Training shall be in the particular operations that the employee performs and in current good manufacturing practice (including the current good manufacturing practice regulations in this chapter and written procedures required by these regulations) as they relate to the employee's functions. Training in current good manufacturing practice shall be conducted by qualified individuals on a continuing basis and with sufficient frequency to assure that employees remain familiar with CGMP requirements applicable to them.” 21 CFR 211.25(b) states that “Each person responsible for supervising the manufacture, processing, packing, or holding of a drug product shall have the education, training, and experience, or any combination thereof, to perform assigned functions in such a manner as to provide assurance that the drug product has the safety, identity, strength, quality, and purity that it purports or is represented to possess.” 21 CFR 211.25(c) states that “There shall be an adequate number of qualified personnel to perform and supervise the manufacture, processing, packing, or holding of each drug product.” 21 CFR 211.28(a) states that “Personnel engaged in the manufacture, processing, packing, or holding of a drug product shall wear clean clothing appropriate for the duties they perform. Protective apparel, such as head, face, hand, and arm coverings, shall be worn as necessary to protect drug products from contamination.” 21 CFR 211.28(b) states that “Personnel shall practice good sanitation and health habits.” 21 CFR 211.28(c) states that “Only personnel authorized by supervisory personnel shall enter those areas of the buildings and facilities designated as limited-access areas.” 21 CFR 211.28(d) states that “Any person shown at any time (either by medical examination or supervisory observation) to have an apparent illness or open lesions that may adversely affect the safety or quality of drug products shall be excluded from direct contact with components, drug product containers, closures, in-process materials, and drug products until the condition is corrected or determined by competent medical personnel not to jeopardize the safety or quality of drug products. All personnel shall be instructed to report to supervisory personnel any health conditions that may have an adverse effect on drug products.” 21 CFR 211.42(c) states, in part, that “Operations shall be performed within specifically defined areas of adequate size. There shall be separate or defined areas or such other control systems for the firm’s operations as are necessary to prevent contamination or mixups during the course of the following procedures: * * * (10) Aseptic processing, which includes as appropriate: * * * (iv) A system for monitoring environmental conditions * * *.” 21 CFR 211.113(b) states that “Appropriate written procedures, designed to prevent microbiological contamination of drug products purporting to be sterile, shall be established and followed. Such procedures shall include validation of any sterilization process.” --- PAGE 17 --- Contains Nonbinding Recommendations A. Personnel A well-designed, maintained, and operated aseptic process minimizes personnel intervention. As operator activities increase in an aseptic processing operation, the risk to finished product sterility also increases. To ensure maintenance of product sterility, it is critical for operators involved in aseptic activities to use aseptic technique at all times. Appropriate training should be conducted before an individual is permitted to enter the aseptic manufacturing area. Fundamental training topics should include aseptic technique, cleanroom behavior, microbiology, hygiene, gowning, patient safety hazards posed by a nonsterile drug product, and the specific written procedures covering aseptic manufacturing area operations. After initial training, personnel should participate regularly in an ongoing training program. Supervisory personnel should routinely evaluate each operator’s conformance to written procedures during actual operations. Similarly, the quality control unit should provide regular oversight of adherence to established, written procedures and aseptic technique during manufacturing operations. Some of the techniques aimed at maintaining sterility of sterile items and surfaces include: • Contact sterile materials only with sterile instruments Sterile instruments should always be used in the handling of sterilized materials. Between uses, sterile instruments should be held under Class 100 (ISO 5) conditions and maintained in a manner that prevents contamination (e.g., placed in sterilized containers). Instruments should be replaced as necessary throughout an operation. After initial gowning, sterile gloves should be regularly sanitized or changed, as appropriate, to minimize the risk of contamination. Personnel should not directly contact sterile products, containers, closures, or critical surfaces with any part of their gown or gloves. • Move slowly and deliberately Rapid movements can create unacceptable turbulence in a critical area. Such movements disrupt the unidirectional airflow, presenting a challenge beyond intended cleanroom design and control parameters. The principle of slow, careful movement should be followed throughout the cleanroom. • Keep the entire body out of the path of unidirectional airflow Unidirectional airflow design is used to protect sterile equipment surfaces, container- closures, and product. Disruption of the path of unidirectional flow air in the critical area can pose a risk to product sterility. • Approach a necessary manipulation in a manner that does not compromise sterility of the product --- PAGE 18 --- Contains Nonbinding Recommendations To maintain sterility of nearby sterile materials, a proper aseptic manipulation should be approached from the side and not above the product (in vertical unidirectional flow operations). Also, operators should refrain from speaking when in direct proximity to the critical area. • Maintain Proper Gown Control Prior to and throughout aseptic operations, an operator should not engage in any activity that poses an unreasonable contamination risk to the gown. Only personnel who are qualified and appropriately gowned should be permitted access to the aseptic manufacturing area. The gown should provide a barrier between the body and exposed sterilized materials and prevent contamination from particles generated by, and microorganisms shed from, the body. The Agency recommends gowns that are sterilized and nonshedding, and cover the skin and hair (face-masks, hoods, beard/moustache covers, protective goggles, and elastic gloves are examples of common elements of gowns). Written procedures should detail the methods used to don each gown component in an aseptic manner. An adequate barrier should be created by the overlapping of gown components (e.g., gloves overlapping sleeves). If an element of a gown is found to be torn or defective, it should be changed immediately. Gloves should be sanitized frequently. There should be an established program to regularly assess or audit conformance of personnel to relevant aseptic manufacturing requirements. An aseptic gowning qualification program should assess the ability of a cleanroom operator to maintain the quality of the gown after performance of gowning procedures. We recommend that this assessment include microbiological surface sampling of several locations on a gown (e.g., glove fingers, facemask, forearm, chest). Sampling sites should be justified. Following an initial assessment of gowning, periodic requalification will provide for the monitoring of various gowning locations over a suitable period to ensure consistent acceptability of aseptic gowning techniques. Annual requalification is normally sufficient for those automated operations where personnel involvement is minimized and monitoring data indicate environmental control. For any aseptic processing operation, if adverse conditions occur, additional or more frequent requalification could be indicated. To protect exposed sterilized product, personnel should to maintain gown quality and strictly adhere to appropriate aseptic techniques. Written procedures should adequately address circumstances under which personnel should be retrained, requalified, or reassigned to other areas. --- PAGE 19 --- Contains Nonbinding Recommendations B. Laboratory Personnel The basic principles of training, aseptic technique, and personnel qualification in aseptic manufacturing also are applicable to those performing aseptic sampling and microbiological laboratory analyses. Processes and systems cannot be considered to be in control and reproducible if the validity of data produced by the laboratory is in question. C. Monitoring Program Personnel can significantly affect the quality of the environment in which the sterile product is processed. A vigilant and responsive personnel monitoring program should be established. Monitoring should be accomplished by obtaining surface samples of each operator's gloves on a daily basis, or in association with each lot. This sampling should be accompanied by an appropriate sampling frequency for other strategically selected locations of the gown (Ref. 5). The quality control unit should establish a more comprehensive monitoring program for operators involved in operations which are especially labor intensive (i.e., those requiring repeated or complex aseptic manipulations). Asepsis is fundamental to an aseptic processing operation. An ongoing goal for manufacturing personnel in the aseptic processing room is to maintain contamination-free gloves and gowns throughout operations. Sanitizing gloves just prior to sampling is inappropriate because it can prevent recovery of microorganisms that were present during an aseptic manipulation. When operators exceed established levels or show an adverse trend, an investigation should be conducted promptly. Follow-up actions can include increased sampling, increased observation, retraining, gowning requalification, and in certain instances, reassignment of the individual to operations outside of the aseptic manufacturing area. Microbiological trending systems, and assessment of the impact of atypical trends, are discussed in more detail under Section X. Laboratory Controls. VI. COMPONENTS AND CONTAINER/CLOSURES 21 CFR 210.3(b)(3) states that “Component means any ingredient intended for use in the manufacture of a drug product, including those that may not appear in such drug product.” 21 CFR 211.80(a) states that “There shall be written procedures describing in sufficient detail the receipt, identification, storage, handling, sampling, testing, and approval or rejection of components and drug product containers and closures; such written procedures shall be followed.” 21 CFR 211.80(b) states that “Components and drug product containers and closures shall at all times be handled and stored in a manner to prevent contamination.” 21 CFR 211.84(d) states, in part, that “Samples shall be examined and tested as follows: * * * (6) Each lot of a component, drug product container, or closure that is liable to microbiological contamination that is objectionable in view of its intended use shall be subjected to microbiological tests before use.” --- PAGE 20 --- Contains Nonbinding Recommendations 21 CFR 211.94(c) states that “Drug product containers and closures shall be clean and, where indicated by the nature of the drug, sterilized and processed to remove pyrogenic properties to assure that they are suitable for their intended use.” 21 CFR 211.94(d) states that “Standards or specifications, methods of testing, and, where indicated, methods of cleaning, sterilizing, and processing to remove pyrogenic properties shall be written and followed for drug product containers and closures.” 21 CFR 211.113(b) states that “Appropriate written procedures, designed to prevent microbiological contamination of drug products purporting to be sterile, shall be established and followed. Such procedures shall include validation of any sterilization process.” A. Components A drug product produced by aseptic processing can become contaminated through the use of one or more components that are contaminated with microorganisms or endotoxins. Examples of components include active ingredients, Water for Injection (WFI), and other excipients. It is important to characterize the microbial content (e.g., bioburden, endotoxin) of each component that could be contaminated and establish appropriate acceptance limits. Endotoxin load data are significant because parenteral products are intended to be nonpyrogenic. There should be written procedures and appropriate specifications for acceptance or rejection of each lot of components that might contain endotoxins. Any components failing to meet defined endotoxin limits should be rejected. In aseptic processing, each component is individually sterilized or several components are combined, with the resulting mixture sterilized.11 Knowledge of bioburden is important in assessing whether a sterilization process is adequate. Several methods can be suitable for sterilizing components (see relevant discussion in Section IX). A widely used method is filtration of a solution formed by dissolving the component(s) in a solvent such as Water For sterilization is used where the component is soluble and is likely to be adversely affected by heat. A variation of this method includes subjecting the filtered solution to aseptic crystallization and precipitation (or lyophilization) of the component as a sterile powder. However, this method involves more handling and manipulation and therefore has a higher potential for contamination during processing. Dry heat sterilization is a suitable method for components that are heat stable and insoluble. However, conducting carefully designed heat penetration and distribution studies is of particular significance for powder sterilization because of the insulating effects of the powder. Irradiation can be used to sterilize some components. Studies should be conducted to demonstrate that the process is appropriate for the component. 11 See Appendix III for discussion of certain biologic components that are aseptically handled from the start of the process. --- PAGE 21 --- Contains Nonbinding Recommendations B. Containers/Closures 1. Preparation Containers and closures should be rendered sterile and, for parenteral drug products, nonpyrogenic. The process used will depend primarily on the nature of the container and/or closure materials. The validation study for such a process should be adequate to demonstrate its ability to render materials sterile and non-pyrogenic. Written procedures should specify the frequency of revalidation of these processes as well as time limits for holding sterile, depyrogenated containers and closures. Pre-sterilization preparation of glass containers usually involves a series of wash and rinse cycles. These cycles serve an important role in removing foreign matter. We recommend use of rinse water of high purity so as not to contaminate containers. For parenteral products, final rinse water should meet the specifications of WFI, USP. The adequacy of the depyrogenation process can be assessed by spiking containers and closures with known quantities of endotoxin, followed by measuring endotoxin content after depyrogenation. The challenge studies can generally be performed by directly applying a reconstituted endotoxin solution onto the surfaces being tested. The endotoxin solution should then be allowed to air dry. Positive controls should be used to measure the percentage of endotoxin recovery by the test method. Validation study data should demonstrate that the process reduces the endotoxin content by at least 99.9 percent (3 logs) (see Section VII).12 Subjecting glass containers to dry heat generally accomplishes both sterilization and depyrogenation. Validation of dry heat sterilization and depyrogenation should include appropriate heat distribution and penetration studies as well as the use of worst-case process cycles, container characteristics (e.g., mass), and specific loading configurations to represent actual production runs. See Section IX.C. Plastic containers used for parenteral products also should be non-pyrogenic. Where applicable, multiple WFI rinses can be effective in removing pyrogens from these containers. Plastic containers can be sterilized with an appropriate gas, irradiation, or other suitable means. For gases such as Ethylene Oxide (EtO), certain issues should receive attention. For example, the parameters and limits of the EtO sterilization cycle (e.g., temperature, pressure, humidity, gas concentration, exposure time, degassing, aeration, and determination of residuals) should be specified and monitored closely. EtO is an effective surface sterilant and is also used to penetrate certain packages with porous overwrapping. Biological indicators are of special importance in demonstrating the effectiveness of EtO and other gas sterilization processes. We recommend that these methods be carefully controlled and validated to evaluate whether consistent penetration of the sterilant can be achieved and to minimize residuals. Residuals from EtO processes typically include ethylene oxide as well as its byproducts, and should be within specified limits. 12 When this level of depyrogenation by dry heat has been successfully validated using endotoxin challenge, a sterilization validation using a biological indicator challenge would not be indicated. --- PAGE 22 --- Contains Nonbinding Recommendations Rubber closures (e.g., stoppers and syringe plungers) can be cleaned by multiple cycles of washing and rinsing prior to final steam or irradiation sterilization. At minimum, the initial rinses for the washing process should employ at least Purified Water, USP, of minimal endotoxin content, followed by final rinse(s) with WFI for parenteral products. Normally, depyrogenation can be achieved by multiple rinses of hot WFI. The time between washing, drying (where appropriate), and sterilizing should be minimized because residual moisture on the stoppers can support microbial growth and the generation of endotoxins. Because rubber is a poor conductor of heat, extra attention is indicated in the validation of processes that use heat with respect to its penetration into the rubber stopper load (See Section IX.C). Validation data from the washing procedure should demonstrate successful endotoxin removal from rubber materials. A potential source of contamination is the siliconization of rubber stoppers. Silicone used in the preparation of rubber stoppers should meet appropriate quality control criteria and not have an adverse effect on the safety, quality, or purity of the drug product. Contract facilities that perform sterilization and/or depyrogenation of containers and closures are subject to the same CGMP requirements as those established for in-house processing. The finished dosage form manufacturer should review and assess the contractor's validation protocol and final validation report. In accord with 211.84(d)(3), a manufacturer who establishes the reliability of the supplier’s test results at appropriate intervals may accept containers or closures based on visual identification and Certificate of Analysis review. 2. Inspection of Container Closure System A container closure system that permits penetration of microorganisms is unsuitable for a sterile product. Any damaged or defective units should be detected, and removed, during inspection of the final sealed product. Safeguards should be implemented to strictly preclude shipment of product that may lack container closure integrity and lead to nonsterility. Equipment suitability problems or incoming container or closure deficiencies can cause loss of container closure system integrity. For example, failure to detect vials fractured by faulty machinery as well as by mishandling of bulk finished stock has led to drug recalls. If damage that is not readily detected leads to loss of container closure integrity, improved procedures should be rapidly implemented to prevent and detect such defects. Functional defects in delivery devices (e.g., syringe device defects, delivery volume) can also result in product quality problems and should be monitored by appropriate in-process testing. Any defects or results outside the specifications established for in-process and final inspection are to be investigated in accord with § 211.192. --- PAGE 23 --- Contains Nonbinding Recommendations VII. ENDOTOXIN CONTROL 21 CFR 211.63 states that “Equipment used in the manufacture, processing, packing, or holding of a drug product shall be of appropriate design, adequate size, and suitably located to facilitate operations for its intended use and for its cleaning and maintenance.” 21 CFR 211.65(a) states that “Equipment shall be constructed so that surfaces that contact components, in-process materials, or drug products shall not be reactive, additive, or absorptive so as to alter the safety, identity, strength, quality, or purity of the drug product beyond the official or other established requirements.” 21 CFR 211.67(a) states that “Equipment and utensils shall be cleaned, maintained, and sanitized at appropriate intervals to prevent malfunctions or contamination that would alter the safety, identify, strength, quality, or purity of the drug product beyond the official or other established requirements.” 21 CFR 211.94(c) states that “Drug product containers and closures shall be clean and, where indicated by the nature of the drug, sterilized and processed to remove pyrogenic properties to assure that they are suitable for their intended use.” 21 CFR 211.167(a) states that “For each batch of drug product purporting to be sterile and/or pyrogen-free, there shall be appropriate laboratory testing to determine conformance to such requirements. The test procedures shall be in writing and shall be followed.” Endotoxin contamination of an injectable product can occur as a result of poor CGMP controls. Certain patient populations (e.g., neonates), those receiving other injections concomitantly, or those administered a parenteral in atypically large volumes or doses can be at greater risk for pyrogenic reaction than anticipated by the established limits based on body weight of a normal healthy adult (Ref. 6, 7). Such clinical concerns reinforce the importance of exercising appropriate CGMP controls to prevent generation of endotoxins. Drug product components, containers, closures, storage time limitations, and manufacturing equipment are among the areas to address in establishing endotoxin control. Adequate cleaning, drying, and storage of equipment will control bioburden and prevent contribution of endotoxin load. Equipment should be designed to be easily assembled and disassembled, cleaned, sanitized, and/or sterilized. If adequate procedures are not employed, endotoxins can be contributed by both upstream and downstream processing equipment. Sterilizing-grade filters and moist heat sterilization have not been shown to be effective in removing endotoxin. Endotoxin on equipment surfaces can be inactivated by high-temperature dry heat, or removed from equipment surfaces by cleaning procedures. Some clean-in-place procedures employ initial rinses with appropriate high purity water and/or a cleaning agent (e.g., acid, base, surfactant), followed by final rinses with heated WFI. Equipment should be dried following cleaning, unless the equipment proceeds immediately to the sterilization step. --- PAGE 24 --- Contains Nonbinding Recommendations VIII. TIME LIMITATIONS 21 CFR 211.111 states that “When appropriate, time limits for the completion of each phase of production shall be established to assure the quality of the drug product. Deviation from established time limits may be acceptable if such deviation does not compromise the quality of the drug product. Such deviation shall be justified and documented.” When appropriate, time limits must be established for each phase of aseptic processing (§ 211.111). Time limits should include, for example, the period between the start of bulk product compounding and its sterilization, filtration processes, product exposure while on the processing line, and storage of sterilized equipment, containers and closures. The time limits established for the various production phases should be supported by data. Bioburden and endotoxin load should be assessed when establishing time limits for stages such as the formulation processing stage. The total time for product filtration should be limited to an established maximum to prevent microorganisms from penetrating the filter. Such a time limit should also prevent a significant increase in upstream bioburden and endotoxin load. Because they can provide a substrate for microbial attachment, maximum use times for those filters used upstream for solution clarification or particle removal should also be established and justified. IX. VALIDATION OF ASEPTIC PROCESSING AND STERILIZATION 21 CFR 211.63, 211.65, and 211.67 address, respectively, “Equipment design, size, and location,” “Equipment construction,” and “Equipment cleaning and maintenance.” 21 CFR 211.84(c) states, in part, that “Samples shall be collected in accordance with the following procedures: * * * (3) Sterile equipment and aseptic sampling techniques shall be used when necessary.” 21 CFR 211.100(a) states, in part, that “There shall be written procedures for production and process control designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess. Such procedures shall include all requirements in this subpart * * *.” 21 CFR 211.113(b) states that “Appropriate written procedures, designed to prevent microbiological contamination of drug products purporting to be sterile, shall be established and followed. Such procedures shall include validation of any sterilization process.” This section primarily discusses routine qualification and validation study recommendations. Change control procedures are addressed only briefly, but are an important part of the quality systems established by a firm. A change in facility, equipment, process, or test method should be evaluated through the written change control program, triggering an evaluation of the need for revalidation or requalification. A. Process Simulations --- PAGE 25 --- Contains Nonbinding Recommendations To ensure the sterility of products purporting to be sterile, sterilization, aseptic filling and closing operations must be adequately validated (§ 211.113). The goal of even the most effective sterilization processes can be defeated if the sterilized elements of a product (the drug formulation, the container, and the closure) are brought together under conditions that contaminate any of those elements. An aseptic processing operation should be validated using a microbiological growth medium in place of the product. This process simulation, also known as a media fill, normally includes exposing the microbiological growth medium to product contact surfaces of equipment, container closure systems, critical environments, and process manipulations to closely simulate the same exposure that the product itself will undergo. The sealed containers filled with the medium are then incubated to detect microbial contamination. Results are then interpreted to assess the potential for a unit of drug product to become contaminated during actual operations (e.g., start-up, sterile ingredient additions, aseptic connections, filling, closing). Environmental monitoring data from the process simulation can also provide useful information for the processing line evaluation. 1. Study Design A media fill program should incorporate the contamination risk factors that occur on a production line, and accurately assesses the state of process control. Media fill studies should closely simulate aseptic manufacturing operations incorporating, as appropriate, worst-case activities and conditions that provide a challenge to aseptic operations. FDA recommends that the media fill program address applicable issues such as: • Factors associated with the longest permitted run on the processing line that can pose contamination risk (e.g., operator fatigue) • Representative number, type, and complexity of normal interventions that occur with each run, as well as nonroutine interventions and events (e.g., maintenance, stoppages, equipment adjustments) • Lyophilization, when applicable • Aseptic assembly of equipment (e.g., at start-up, during processing) • Number of personnel and their activities • Representative number of aseptic additions (e.g., charging containers and closures as well as sterile ingredients) or transfers • Shift changes, breaks, and gown changes (when applicable) • Type of aseptic equipment disconnections/connections • Aseptic sample collections • Line speed and configuration • Weight checks • Container closure systems (e.g., sizes, type, compatibility with equipment) --- PAGE 26 --- Contains Nonbinding Recommendations • Specific provisions in written procedures relating to aseptic processing (e.g., conditions permitted before line clearance is mandated) A written batch record, documenting production conditions and simulated activities, should be prepared for each media fill run. The same vigilance should be observed in both media fill and routine production runs. The firm’s rationale for the conditions and activities simulated during the media fill should be clearly defined. Media fills should not be used to justify practices that pose unnecessary contamination risks. 2. Frequency and Number of Runs When a processing line is initially qualified, individual media fills should be repeated enough times to ensure that results are consistent and meaningful. This approach is important because a single run can be inconclusive, while multiple runs with divergent results signal a process that is not in control. We recommend that at least three consecutive separate successful runs be performed during initial line qualification. Subsequently, routine semi-annual qualification conducted for each processing line will evaluate the state of control of the aseptic process. Activities and interventions representative of each shift, and shift changeover, should be incorporated into the design of the semi-annual qualification program. For example, the evaluation of a production shift should address its unique time-related and operational features.13 All personnel who are authorized to enter the aseptic processing room during manufacturing, including technicians and maintenance personnel, should participate in a media fill at least once a year. Participation should be consistent with the nature of each operator’s duties during routine production. Each change to a product or line change should be evaluated using a written change control system. Any changes or events that have the potential to affect the ability of the aseptic process to exclude contamination from the sterilized product should be assessed through additional media fills. For example, facility and equipment modifications, line configuration changes, significant changes in personnel, anomalies in environmental testing results, container closure system changes, extended shutdowns, or end product sterility testing showing contaminated products may be cause for revalidation of the system. When data from a media fill indicate the process may not be in control, an investigation should be conducted to determine the origin of the contamination and the scope of the problem. Once corrections are instituted, process simulation run(s) should be performed to confirm that deficiencies have been corrected and the process has returned to a state of control. When an investigation fails to reach well-supported, substantive conclusions as to the cause of the media fill failure, three consecutive successful runs in tandem with increased scrutiny of the production process may be warranted. 3. Duration of Runs 13 One example might be the movement of personnel into and out of the aseptic processing and gowning change rooms during a shift change. --- PAGE 27 --- Contains Nonbinding Recommendations The duration of aseptic processing operations is a major consideration in media fill design. Although the most accurate simulation model would be the full batch size and duration because it most closely simulates the actual production operations, other appropriate models can be justified. The duration of the media fill run should be determined by the time it takes to incorporate manipulations and interventions, as well as appropriate consideration of the duration of the actual aseptic processing operation. Interventions that commonly occur should be routinely simulated, while those occurring rarely can be simulated periodically. While conventional manufacturing lines are usually automated, operated at relatively high speeds, and designed to limit operator intervention, some processes still include considerable operator involvement. When aseptic processing employs manual filling or closing, or extensive manual manipulations, the duration of the process simulation should generally be no less than the length of the actual manufacturing process to best simulate contamination risks posed by operators. For lyophilization operations, FDA recommends that unsealed containers be exposed to partial evacuation of the chamber in a manner that simulates the process. Vials should not be frozen, and precautions should be taken that ensure that the medium remains in an aerobic state to avoid potentially inhibiting the growth of microorganisms. 4. Size of Runs The simulation run sizes should be adequate to mimic commercial production conditions and accurately assess the potential for commercial batch contamination. The number of units filled during the process simulation should be based on contamination risk for a given process and sufficient to accurately simulate activities that are representative of the manufacturing process. A generally acceptable starting point for run size is in the range of 5,000 to 10,000 units. For operations with production sizes under 5,000, the number of media filled units should at least equal the maximum batch size made on the processing line (Ref. 8). When the possibility of contamination is higher based on the process design (e.g., manually intensive filling lines), a larger number of units, generally at or approaching the full production batch size, should be used. In contrast, a process conducted in an isolator (see Appendix 1) can have a low risk of contamination because of the lack of direct human intervention and can be simulated with a lower number of units as a proportion of the overall operation. Media fill size is an especially important consideration because some batches are produced over multiple shifts or yield an unusually large number of units. These factors should be carefully evaluated when designing the simulation to adequately encompass conditions and any potential risks associated with the larger operation. 5. Line Speed The media fill program should adequately address the range of line speeds employed during production. Each media fill run should evaluate a single line speed, and the speed chosen should be justified. For example, use of high line speed is often most appropriate in the evaluation of manufacturing processes characterized by frequent interventions or a significant degree of --- PAGE 28 --- Contains Nonbinding Recommendations manual manipulation. Use of slow line speed is generally appropriate for evaluating manufacturing processes with prolonged exposure of the sterile drug product and containers/closures in the aseptic area. 6. Environmental Conditions Media fills should be adequately representative of the conditions under which actual manufacturing operations are conducted. An inaccurate assessment (making the process appear cleaner than it actually is) can result from conducting a media fill under extraordinary air particulate and microbial quality, or under production controls and precautions taken in preparation for the media fill. To the extent standard operating procedures permit stressful conditions (e.g., maximum number of personnel present and elevated activity level), it is important that media fills include analogous challenges to support the validity of these studies. Stressful conditions do not include artificially created environmental extremes, such as reconfiguration of HVAC systems to operate at worst-case limits. 7. Media In general, a microbiological growth medium, such as soybean casein digest medium, should be used. Use of anaerobic growth media (e.g., fluid thioglycollate medium) should be considered in special circumstances. The media selected should be demonstrated to promote growth of gram- positive and gram-negative bacteria, and yeast and mold (e.g., USP indicator organisms). The QC laboratory should determine if USP indicator organisms sufficiently represent production- related isolates. Environmental monitoring and sterility test isolates can be substituted (as appropriate) or added to the growth promotion challenge. Growth promotion units should be inoculated with a <100 CFU challenge. If the growth promotion testing fails, the origin of any contamination found during the simulation should nonetheless be investigated and the media fill promptly repeated.14 The production process should be accurately simulated using media and conditions that optimize detection of any microbiological contamination. Each unit should be filled with an appropriate quantity and type of microbial growth medium to contact the inner container closure surfaces (when the unit is inverted or thoroughly swirled) and permit visual detection of microbial growth. Some drug manufacturers have expressed concern over the possible contamination of the facility and equipment with nutrient media during media fill runs. However, if the medium is handled properly and is promptly followed by the cleaning, sanitizing, and, where necessary, sterilization of equipment, subsequently processed products are not likely to be compromised. 8. Incubation and Examination of Media-Filled Units Media units should be incubated under conditions adequate to detect microorganisms that might otherwise be difficult to culture. Incubation conditions should be established in accord with the following general guidelines: 14 The cause of the growth promotion failure should also be investigated. --- PAGE 29 --- Contains Nonbinding Recommendations • Incubation temperature should be suitable for recovery of bioburden and environmental isolates and should at no time be outside the range of 20-35oC. Incubation temperature should be maintained within +2.5oC of the target temperature. • Incubation time should not be less than 14 days. If two temperatures are used for the incubation of the media filled units, the units should be incubated for at least 7 days at each temperature (starting with the lower temperature). Each media-filled unit should be examined for contamination by personnel with appropriate education, training, and experience in inspecting media fill units for microbiological contamination. If QC personnel do not perform the inspection, there should be QC unit oversight throughout any such examination. All suspect units identified during the examination should be brought to the immediate attention of the QC microbiologist. To allow for visual detection of microbial growth, we recommend substituting clear containers (with otherwise identical physical properties) for amber or other opaque containers. If appropriate, other methods can also be considered to ensure visual detection. When a firm performs a final product inspection of units immediately following the media fill run, all integral units should proceed to incubation. Units found to have defects not related to integrity (e.g., cosmetic defect) should be incubated; units that lack integrity should be rejected. Erroneously rejected units should be returned promptly for incubation with the media fill lot. After incubation is underway, any unit found to be damaged should be included in the data for the media fill run, because the units can be representative of drug product released to the market. Any decision to exclude such incubated units (i.e., non-integral) from the final run tally should be fully justified and the deviation explained in the media fill report. If a correlation emerges between difficult to detect damage and microbial contamination, a thorough investigation should be conducted to determine its cause (see Section VI.B). Written procedures regarding aseptic interventions should be clear and specific (e.g., intervention type; quantity of units removed), providing for consistent production practices and assessment of these practices during media fills. If written procedures and batch documentation are adequate to describe an associated clearance, the intervention units removed during media fills do not need to be incubated.15 Where procedures lack specificity, there would be insufficient justification for exclusion of units removed during an intervention from incubation. For example, if a production procedure requires removal of 10 units after an intervention at the stoppering station infeed, batch records (i.e., for production and media fills) should clearly document conformance with this procedure. In no case should more units be removed during a media fill intervention than would be cleared during a production run. The ability of a media fill run to detect potential contamination from a given simulated activity should not be compromised by a large-scale line clearance. We recommend incorporating 15 To assess contamination risks during initial aseptic setup (before fill), valuable information can be obtained by incubating all such units that may be normally removed. These units are typically incubated separately, and would not necessarily be included in the acceptance criteria for the media fill. --- PAGE 30 --- Contains Nonbinding Recommendations appropriate study provisions to avoid and address a large line clearance that results in the removal of a unit possibly contaminated during an unrelated event or intervention. Appropriate criteria should be established for yield16 and accountability (reconciliation of filled units). Media fill record reconciliation documentation should include a full accounting and description of units rejected from a batch. 9. Interpretation of Test Results The process simulation run should be observed by the QC Unit, and contaminated units should be reconcilable with the approximate time and the activity being simulated during the media fill. Video recording of a media fill may serve as a useful aide in identifying personnel practices that could negatively affect the aseptic process. Any contaminated unit should be considered objectionable and investigated. The microorganisms should be identified to species level. The investigation should survey the possible causes of contamination. In addition, any failure investigation should assess the impact on commercial drugs produced on the line since the last media fill. Whenever contamination exists in a media fill run, it should be considered indicative of a potential sterility assurance problem, regardless of run size. The number of contaminated units should not be expected to increase in a directly proportional manner with the number of vials in the media fill run. Test results should reliably and reproducibly show that the units produced by an aseptic processing operation are sterile. Modern aseptic processing operations in suitably designed facilities have demonstrated a capability of meeting contamination levels approaching zero (Ref. 8, 9) and should normally yield no media fill contamination. Recommended criteria for assessing state of aseptic line control are as follows: • When filling fewer than 5000 units, no contaminated units should be detected. -- One (1) contaminated unit is considered cause for revalidation, following an investigation. • When filling from 5,000 to 10,000 units: -- One (1) contaminated unit should result in an investigation, including consideration of a repeat media fill. -- Two (2) contaminated units are considered cause for revalidation, following investigation. • When filling more than 10,000 units: -- One (1) contaminated unit should result in an investigation. -- Two (2) contaminated units are considered cause for revalidation, following investigation. For any run size, intermittent incidents of microbial contamination in media filled runs can be indicative of a persistent low-level contamination problem that should be investigated. 16Total units incubated/total number of units filled. --- PAGE 31 --- Contains Nonbinding Recommendations Accordingly, recurring incidents of contaminated units in media fills for an individual line, regardless of acceptance criteria, would be a signal of an adverse trend on the aseptic processing line that should lead to problem identification, correction, and revalidation. A firm's use of media fill acceptance criteria allowing infrequent contamination does not mean that a distributed lot of drug product purporting to be sterile may contain a nonsterile unit. The purpose of an aseptic process is to prevent any contamination. A manufacturer is fully liable for the shipment of any nonsterile unit, an act that is prohibited under the FD&C Act (Section 301(a) 21 U.S.C. 331(a)). FDA also recognizes that there might be some scientific and technical limitations on how precisely and accurately process simulations can characterize a system of controls intended to exclude contamination. As with any process validation run, it is important to note that invalidation of a media fill run should be a rare occurrence. A media fill run should be aborted only under circumstances in which written procedures require commercial lots to be equally handled. Supporting documentation and justification should be provided in such cases. B. Filtration Efficacy Filtration is a common method of sterilizing drug product solutions. A sterilizing grade filter should be validated to reproducibly remove viable microorganisms from the process stream, producing a sterile effluent.17 Currently, such filters usually have a rated pore size of 0.2 µm or smaller.18 Use of redundant sterilizing filters should be considered in many cases. Whatever filter or combination of filters is used, validation should include microbiological challenges to simulate worst-case production conditions for the material to be filtered and integrity test results of the filters used for the study. Product bioburden should be evaluated when selecting a suitable challenge microorganism to assess which microorganism represents the worst-case challenge to the filter. The microorganism Brevundimonas diminuta (ATCC 19146) when properly grown, harvested and used, is a common challenge microorganism for 0.2 µm rated filters because of its small size (0.3 µm mean diameter). The manufacturing process controls should be designed to minimize the bioburden of the unfiltered product. Bioburden of unsterilized bulk solutions should be determined to trend the characteristics of potentially contaminating organisms. In certain cases, when justified as equivalent or better than use of B. diminuta, it may be appropriate to conduct bacterial retention studies with a bioburden isolate. The number of microorganisms in the challenge is important because a filter can contain a number of pores larger than the nominal rating, which has the potential to allow passage of microorganisms. The probability of such passage is considered to increase as the number of organisms (bioburden) in the material to be filtered increases. A challenge concentration of at least 107 organisms per cm2 of effective filtration area should generally be used, resulting in no passage of the challenge microorganism. The challenge concentration used for validation is intended to provide a margin of safety well beyond what would be expected in production. 17 This document does not address virus removal. 18 0.22µ and 0.2µ are considered interchangeable nominal pore size ratings. --- PAGE 32 --- Contains Nonbinding Recommendations Direct inoculation into the drug formulation is the preferred method because it provides an assessment of the effect of drug product on the filter matrix and on the challenge organism. However, directly inoculating B. diminuta into products with inherent bactericidal activity against this microbe, or into oil-based formulations, can lead to erroneous conclusions. When sufficiently justified, the effects of the product formulation on the membrane's integrity can be assessed using an appropriate alternate method. For example, a drug product could be filtered in a manner in which the worst-case combination of process specifications and conditions are simulated. This step could be followed by filtration of the challenge organism for a significant period of time, under the same conditions, using an appropriately modified product (e.g., lacking an antimicrobial preservative or other antimicrobial component) as the vehicle. Any divergence from a simulation using the actual product and conditions of processing should be justified. Factors that can affect filter performance generally include (1) viscosity and surface tension of the material to be filtered, (2) pH, (3) compatibility of the material or formulation components with the filter itself, (4) pressures, (5) flow rates, (6) maximum use time, (7) temperature, (8) osmolality, (9) and the effects of hydraulic shock. When designing the validation protocol, it is important to address the effect of the extremes of processing factors on the filter capability to produce sterile effluent. Filter validation should be conducted using the worst-case conditions, such as maximum filter use time and pressure (Ref. 12). Filter validation experiments, including microbial challenges, need not be conducted in the actual manufacturing areas. However, it is essential that laboratory experiments simulate actual production conditions. The specific type of filter membrane used in commercial production should be evaluated in filter validation studies. There are advantages to using production filters in these bacterial retention validation studies. When the more complex filter validation tests go beyond the capabilities of the filter user, tests are often conducted by outside laboratories or by filter manufacturers. However, it is the responsibility of the filter user to review the validation data on the efficacy of the filter in producing a sterile effluent. The data should be applicable to the user's products and conditions of use because filter performance may differ significantly for various conditions and products. After a filtration process is properly validated for a given product, process, and filter, it is important to ensure that identical filters (e.g., of identical polymer construction and pore size rating) are used in production runs. Sterilizing filters should be routinely discarded after processing of a single lot. However, in those instances when repeated use can be justified, the sterile filter validation should incorporate the maximum number of lots to be processed. Integrity testing of the filter(s) can be performed prior to processing, and should be routinely performed post-use. It is important that integrity testing be conducted after filtration to detect any filter leaks or perforations that might have occurred during the filtration. Forward flow and bubble point tests, when appropriately employed, are two integrity tests that can be used. A production filter’s integrity test specification should be consistent with data generated during bacterial retention validation studies. C. Sterilization of Equipment, Containers, and Closures Equipment surfaces that contact sterilized drug product or its sterilized containers or closures must be sterile so as not to alter purity of the drug (211.67 and 211.113). Where reasonable contamination potential exists, surfaces that are in the vicinity of the sterile product should also be rendered free of viable organisms. It is as important in aseptic processing to validate the --- PAGE 33 --- Contains Nonbinding Recommendations processes used to sterilize such critical equipment as it is to validate processes used to sterilize the drug product and its container and closure. Moist heat and dry heat sterilization, the most widely used, are the primary processes discussed in this document. However, many of the heat sterilization principles discussed in this guidance are also applicable to other sterilization methods. Sterility of aseptic processing equipment should normally be maintained by sterilization between each batch.19 Following sterilization, transportation and assembly of equipment, containers, and closures should be performed with strict adherence to aseptic methods in a manner that protects and sustains the product's sterile state. 1. Qualification and Validation Validation studies should be conducted to demonstrate the efficacy of the sterilization cycle. Requalification studies should also be performed on a periodic basis. The specific load configurations, as well as biological indicator and temperature sensor locations, should be documented in validation records. Batch production records should subsequently document adherence to the validated load patterns. It is important to remove air from the autoclave chamber as part of a steam sterilization cycle. The insulating properties of air interfere with the ability of steam to transfer its energy to the load, achieving lower lethality than associated with saturated steam. It also should be noted that the resistance of microorganisms can vary widely depending on the material to be sterilized. For this reason, careful consideration should be given during sterilization validation to the nature or type of material chosen as the carrier of the biological indicator to ensure an appropriately representative study. Potentially difficult to reach locations within the sterilizer load or equipment train (for SIP applications) should be evaluated. For example, filter installations in piping can cause a substantial pressure differential across the filter, resulting in a significant temperature drop on the downstream side. We recommend placing biological indicators at appropriate downstream locations of the filter. Empty chamber studies evaluate numerous locations throughout a sterilizing unit (e.g., steam autoclave, dry heat oven) or equipment train (e.g., large tanks, immobile piping) to confirm uniformity of conditions (e.g., temperature, pressure). These uniformity or mapping studies should be conducted with calibrated measurement devices. Heat penetration studies should be performed using the established sterilizer loads. Validation of the sterilization process with a loaded chamber demonstrates the effects of loading on thermal input to the items being sterilized and may identify difficult to heat or penetrate items where there could be insufficient lethality to attain sterility. The placement of biological indicators at numerous positions in the load, including the most difficult to sterilize places, is a direct means of confirming the efficacy of any sterilization procedure. In general, the biological indicator should be placed adjacent to the temperature sensor so as to assess the correlation between microbial lethality and predicted lethality based on thermal input. When determining which 19 If appropriate, alternate intervals can be defined, justified, and supported by validation studies. --- PAGE 34 --- Contains Nonbinding Recommendations articles are difficult to sterilize, special attention should be given to the sterilization of filters, filling manifolds, and pumps. Some other examples include certain locations of tightly wrapped or densely packed supplies, securely fastened load articles, lengthy tubing, the sterile filter apparatus, hydrophobic filters, and stopper load. Ultimately, cycle specifications for such sterilization methods should be based on the delivery of adequate lethality to the slowest to heat locations. A sterility assurance level of 10-6 or better should be demonstrated for a sterilization process. For more information, please also refer to the FDA guidance entitled Guideline for the Submission of Documentation for Sterilization Process Validation in Applications for Human and Veterinary Drug Products. The sterilizer validation program should continue to focus on the load areas identified as most difficult to penetrate or heat. The suitability of the sterilizer should be established by qualification, maintenance, change control, and periodic verification of the cycle, including biological challenges. Change control procedures should adequately address issues such as a load configuration change or a modification of a sterilizer. 2. Equipment Controls and Instrument Calibration For both validation and routine process control, the reliability of the data generated by sterilization cycle monitoring devices should be considered to be of the utmost importance. Devices that measure cycle parameters should be routinely calibrated. Written procedures should be established to ensure that these devices are maintained in a calibrated state. For example, we recommend that procedures address the following: • Temperature and pressure monitoring devices for heat sterilization should be calibrated at suitable intervals. The sensing devices used for validation studies should be calibrated before and after validation runs. • Devices used to monitor dwell time in the sterilizer should be periodically calibrated. • The microbial count of a biological indicator should be confirmed. Biological indicators should be stored under appropriate conditions. • If the reliability of a vendor’s Certificate of Analysis is established through an appropriate qualification program, the D-value of a biological indicator (e.g., spore strips, glass ampuls) can be accepted in lieu of confirmatory testing of each lot. However, a determination of resistance (D-value) should be performed for any biological indicator inoculated onto a substrate, or used in a way that is other than described by the vendor. D-value determinations can be conducted by an independent laboratory. • Where applicable, instruments used to determine the purity of steam should be calibrated. • For dry heat depyrogenation tunnels, devices (e.g. sensors and transmitters) used to measure belt speed should be routinely calibrated. Bacterial endotoxin challenges should be appropriately prepared and measured by the laboratory. To ensure robust process control, equipment should be properly designed with attention to features such as accessibility to sterilant, piping slope, and proper condensate removal (as applicable). Equipment control should be ensured through placement of measuring devices at --- PAGE 35 --- Contains Nonbinding Recommendations those control points that are most likely to rapidly detect unexpected process variability. Where manual manipulations of valves are required for sterilizer or SIP operations, these steps should be documented in manufacturing procedures and batch records. Sterilizing equipment should be properly maintained to allow for consistent, satisfactory function. Routine evaluation of sterilizer performance-indicating attributes, such as equilibrium (come up) time is important in assuring that the unit continues to operate as per the validated conditions. X. LABORATORY CONTROLS 21 CFR 211.22(b) states that “Adequate laboratory facilities for the testing and approval (or rejection) of components, drug product containers, closures, packaging materials, in-process materials, and drug products shall be available to the quality control unit.” 21 CFR 211.22(c) states that “The quality control unit shall have the responsibility for approving or rejecting all procedures or specifications impacting on the identity, strength, quality, and purity of the drug product.” 21 CFR 211.42(c) states, in part, that “Operations shall be performed within specifically defined areas of adequate size. There shall be separate or defined areas or such other control systems for the firm’s operations as are necessary to prevent contamination or mixups during the course of the following procedures: * * * (10) Aseptic processing, which includes as appropriate: * * * (iv) A system for monitoring environmental conditions; * * *.” 21 CFR 211.56(b) states that “There shall be written procedures assigning responsibility for sanitation and describing in sufficient detail the cleaning schedules, methods, equipment, and materials to be used in cleaning the buildings and facilities; such written procedures shall be followed.” 21 CFR 211.56(c) states, in part, that “There shall be written procedures for use of suitable rodenticides, insecticides, fungicides, fumigating agents, and cleaning and sanitizing agents. Such written procedures shall be designed to prevent the contamination of equipment, components, drug product containers, closures, packaging, labeling materials, or drug products and shall be followed * * *.” 21 CFR 211.110(a) states, in part, that “To assure batch uniformity and integrity of drug products, written procedures shall be established and followed that describe the in-process controls, and tests, or examinations to be conducted on appropriate samples of in-process materials of each batch. Such control procedures shall be established to monitor the output and to validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product * * *.” 21 CFR 211.113(b) states that “Appropriate written procedures, designed to prevent microbiological contamination of drug products purporting to be sterile, shall be established and followed. Such procedures shall include validation of any sterilization process.” 21 CFR 211.160(b) states that “Laboratory controls shall include the establishment of scientifically sound and appropriate specifications, standards, sampling plans, and test procedures designed to assure that components, drug product containers, closures, in-process materials, labeling, and drug products conform to appropriate standards of identity, strength, quality, and purity. Laboratory controls shall include: (1) Determination of conformance to appropriate written specifications for the acceptance of each lot within each shipment of components, drug product containers, closures, and labeling used in the manufacture, processing, packing, or holding of drug products. The specifications shall include a description of the sampling and testing procedures used. Samples shall be representative and adequately identified. Such procedures shall also require appropriate retesting of any component, drug product container, or closure that is subject to deterioration. (2) Determination of conformance to written specifications and a description of sampling and testing procedures for in-process materials. Such samples shall be representative and --- PAGE 36 --- Contains Nonbinding Recommendations properly identified. (3) Determination of conformance to written descriptions of sampling procedures and appropriate specifications for drug products. Such samples shall be representative and properly identified. (4) The calibration of instruments, apparatus, gauges, and recording devices at suitable intervals in accordance with an established written program containing specific directions, schedules, limits for accuracy and precision, and provisions for remedial action in the event accuracy and/or precision limits are not met. Instruments, apparatus, gauges, and recording devices not meeting established specifications shall not be used.” 21 CFR 211.165(e) states that “The accuracy, sensitivity, specificity, and reproducibility of test methods employed by the firm shall be established and documented. Such validation and documentation may be accomplished in accordance with § 211.194(a)(2).” 21 CFR 211.192 states, in part, that “All drug product production and control records, including those for packaging and labeling, shall be reviewed and approved by the quality control unit to determine compliance with all established, approved written procedures before a batch is released or distributed * * *.” A. Environmental Monitoring 1. General Written Program In aseptic processing, one of the most important laboratory controls is the environmental monitoring program. This program provides meaningful information on the quality of the aseptic processing environment (e.g., when a given batch is being manufactured) as well as environmental trends of ancillary clean areas. Environmental monitoring should promptly identify potential routes of contamination, allowing for implementation of corrections before product contamination occurs (211.42 and 211.113). Evaluating the quality of air and surfaces in the cleanroom environment should start with a well- defined written program and scientifically sound methods. The monitoring program should cover all production shifts and include air, floors, walls, and equipment surfaces, including the critical surfaces that come in contact with the product, container, and closures. Written procedures should include a list of locations to be sampled. Sample timing, frequency, and location should be carefully selected based upon their relationship to the operation performed. Samples should be taken throughout the classified areas of the aseptic processing facility (e.g., aseptic corridors, gowning rooms) using scientifically sound sampling procedures. Sample sizes should be sufficient to optimize detection of environmental contaminants at levels that might be expected in a given clean area. It is important that locations posing the most microbiological risk to the product be a key part of the program. It is especially important to monitor the microbiological quality of the critical area to determine whether or not aseptic conditions are maintained during filling and closing activities. Air and surface samples should be taken at the locations where significant activity or product exposure occurs during production. Critical surfaces that come in contact with the sterile product should remain sterile throughout an operation. When identifying critical sites to be sampled, consideration should be given to the points of contamination risk in a process, including factors such as difficulty of setup, length of processing time, and impact of interventions. Critical surface sampling should be performed at the conclusion of the aseptic processing operation to avoid direct contact with sterile surfaces during processing. Detection of microbial contamination on a critical site would not necessarily result in batch rejection. The --- PAGE 37 --- Contains Nonbinding Recommendations contaminated critical site sample should prompt an investigation of operational information and data that includes an awareness of the potential for a low incidence of false positives. Environmental monitoring methods do not always recover microorganisms present in the sampled area. In particular, low-level contamination can be particularly difficult to detect. Because false negatives can occur, consecutive growth results are only one type of adverse trend. Increased incidence of contamination over a given period is an equal or more significant trend to be tracked. In the absence of any adverse trend, a single result above an action level should trigger an evaluation and a determination about whether remedial measures may be appropriate. In all room classes, remedial measures should be taken in response to unfavorable trends. All environmental monitoring locations should be described in SOPs with sufficient detail to allow for reproducible sampling of a given location surveyed. Written SOPs should also address elements such as (1) frequency of sampling, (2) when the samples are taken (i.e., during or at the conclusion of operations), (3) duration of sampling, (4) sample size (e.g., surface area, air volume), (5) specific sampling equipment and techniques, (6) alert and action levels, and (7) appropriate response to deviations from alert or action levels. 2. Establishing Levels and a Trending Program Microbiological monitoring levels should be established based on the relationship of the sampled location to the operation. The levels should be based on the need to maintain adequate microbiological control throughout the entire sterile manufacturing facility. One should also consider environmental monitoring data from historical databases, media fills, cleanroom qualification, and sanitization studies, in developing monitoring levels. Data from similar operations can also be helpful in setting action and alert levels, especially for a new operation. Environmental monitoring data will provide information on the quality of the manufacturing environment. Each individual sample result should be evaluated for its significance by comparison to the alert or action levels. Averaging of results can mask unacceptable localized conditions. A result at the alert level urges attention to the approaching action conditions. A result at the action level should prompt a more thorough investigation. Written procedures should be established, detailing data review frequency and actions to be taken. The quality control unit should provide routine oversight of near-term (e.g., daily, weekly, monthly, quarterly) and long-term trends in environmental and personnel monitoring data. Trend reports should include data generated by location, shift, room, operator, or other parameters. The quality control unit should be responsible for producing specialized data reports (e.g., a search on a particular isolate over a year period) with the goal of investigating results beyond established levels and identifying any appropriate follow-up actions. Significant changes in microbial flora should be considered in the review of the ongoing environmental monitoring data. Written procedures should define the system whereby the most responsible managers are regularly informed and updated on trends and investigations. --- PAGE 38 --- Contains Nonbinding Recommendations 3. Disinfection Efficacy The suitability, efficacy, and limitations of disinfecting agents and procedures should be assessed. The effectiveness of these disinfectants and procedures should be measured by their ability to ensure that potential contaminants are adequately removed from surfaces. To prevent introduction of contamination, disinfectants should be sterile, appropriately handled in suitable (e.g., sterile) containers and used for no longer than the predefined period specified by written procedures. Routinely used disinfectants should be effective against the normal microbial vegetative flora recovered from the facility. Many common disinfectants are ineffective against spores. For example, 70 percent isopropyl alcohol is ineffective against Bacillus spp. spores. Therefore, a sound disinfectant program also includes a sporicidal agent, used according to a written schedule and when environmental data suggest the presence of sporeforming organisms. Disinfection procedures should be described in sufficient detail (e.g., preparation, work sequence, contact time) to enable reproducibility. Once the procedures are established, their adequacy should be evaluated using a routine environmental monitoring program. If indicated, microorganisms associated with adverse trends can be investigated as to their sensitivity to the disinfectants employed in the cleanroom in which the organisms were isolated. 4. Monitoring Methods Acceptable methods for monitoring the microbiological quality of the environment include: a. Surface Monitoring Environmental monitoring involves sampling various surfaces for microbiological quality. For example, product contact surfaces, floors, walls, and equipment should be tested on a regular basis. Touch plates, swabs, and contact plates can be used for such tests. b. Active Air Monitoring Assessing microbial quality of air should involve the use of active devices including but not limited to impaction, centrifugal, and membrane (or gelatin) samplers. Each device has certain advantages and disadvantages, although all allow testing of the number of organisms per volume of air sampled. We recommend that such devices be used during each production shift to evaluate aseptic processing areas at carefully chosen locations. Manufacturers should be aware of a device's air monitoring capabilities, and the air sampler should be evaluated for its suitability for use in an aseptic environment based on collection efficiency, cleanability, ability to be sterilized, and disruption of unidirectional airflow.20 Because devices vary, the user should assess the overall suitability of a monitoring device before it is placed into service. Manufacturers should ensure that such devices are calibrated and used according to appropriate procedures. 20 For example, the volume of air sampled should be sufficient to yield meaningful measurements of air quality in a given environment. --- PAGE 39 --- Contains Nonbinding Recommendations c. Passive Air Monitoring (Settling Plates) Another method is the use of passive air samplers, such as settling plates (petri dishes containing nutrient growth medium exposed to the environment). Because only microorganisms that settle onto the agar surface are detected, settling plates can be used as qualitative, or semi-quantitative, air monitors. Their value in critical areas will be enhanced by ensuring that plates are positioned in locations posing the greatest risk of product contamination. As part of methods validation, the quality control laboratory should evaluate what media exposure conditions optimize recovery of low levels of environmental isolates. Exposure conditions should preclude desiccation (e.g., caused by lengthy sampling periods and/or high airflows), which inhibits recovery of microorganisms. The data generated by passive air sampling can be useful when considered in combination with results from other types of air samples. B. Microbiological Media and Identification Characterization of recovered microorganisms provides vital information for the environmental monitoring program. Environmental isolates often correlate with the contaminants found in a media fill or product sterility testing failure, and the overall environmental picture provides valuable information for an investigation. Monitoring critical and immediately surrounding clean areas as well as personnel should include routine identification of microorganisms to the species (or, where appropriate, genus) level. In some cases, environmental trending data have revealed migration of microorganisms into the aseptic processing room from either uncontrolled or lesser controlled areas. Establishing an adequate program for differentiating microorganisms in the lesser-controlled environments, such as Class 100,000 (ISO 8), can often be instrumental in detecting such trends. At minimum, the program should require species (or, where appropriate, genus) identification of microorganisms in these ancillary environments at frequent intervals to establish a valid, current database of contaminants present in the facility during processing (and to demonstrate that cleaning and sanitization procedures continue to be effective). Genotypic methods have been shown to be more accurate and precise than traditional biochemical and phenotypic techniques. These methods are especially valuable for investigations into failures (e.g., sterility test; media fill contamination). However, appropriate biochemical and phenotypic methods can be used for the routine identification of isolates. The goal of microbiological monitoring is to reproducibly detect microorganisms for purposes of monitoring the state of environmental control. Consistent methods will yield a database that allows for sound data comparisons and interpretations. The microbiological culture media used in environmental monitoring should be validated as capable of detecting fungi (i.e., yeasts and molds) as well as bacteria and incubated at appropriate conditions of time and temperature. Total aerobic bacterial count can be obtained by incubating at 30 to 35oC for 48 to 72 hours. Total combined yeast and mold count can generally be obtained by incubating at 20 to 25oC for 5 to 7 days. --- PAGE 40 --- Contains Nonbinding Recommendations Incoming lots of environmental monitoring media should be tested for their ability to reliably recover microorganisms. Growth promotion testing should be performed on all lots of prepared media. Where appropriate, inactivating agents should be used to prevent inhibition of growth by cleanroom disinfectants or product residuals (e.g., antibiotics). C. Prefiltration Bioburden Manufacturing process controls should be designed to minimize the bioburden in the unfiltered product. In addition to increasing the challenge to the sterilizing filter, bioburden can contribute impurities (e.g., endotoxin) to, and lead to degradation of, the drug product. A prefiltration bioburden limit should be established. D. Alternate Microbiological Test Methods Other suitable microbiological test methods (e.g., rapid test methods) can be considered for environmental monitoring, in-process control testing, and finished product release testing after it is demonstrated that the methods are equivalent or better than traditional methods (e.g.,USP). E. Particle Monitoring Routine particle monitoring is useful in rapidly detecting significant deviations in air cleanliness from qualified processing norms (e.g., clean area classification). A result outside the established classification level at a given location should be investigated as to its cause. The extent of investigation should be consistent with the severity of the excursion and include an evaluation of trending data. Appropriate corrective action should be implemented, as necessary, to prevent future deviations. See Section IV.A for additional guidance on particle monitoring. --- PAGE 41 --- Contains Nonbinding Recommendations XI. STERILITY TESTING 21 CFR 210.3(b)(21) states that “Representative sample means a sample that consists of a number of units that are drawn based on rational criteria such as random sampling and intended to assure that the sample accurately portrays the material being sampled.” 21 CFR 211.110(a) states, in part, that “To assure batch uniformity and integrity of drug products, written procedures shall be established and followed that describe the in-process controls, and tests, or examinations to be conducted on appropriate samples of in-process materials of each batch. Such control procedures shall be established to monitor the output and to validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.” 21 CFR 211.160(b) states that “Laboratory controls shall include the establishment of scientifically sound and appropriate specifications, standards, sampling plans, and test procedures designed to assure that components, drug product containers, closures, in-process materials, labeling, and drug products conform to appropriate standards of identity, strength, quality, and purity. Laboratory controls shall include: (1) Determination of conformance to appropriate written specifications for the acceptance of each lot within each shipment of components, drug product containers, closures, and labeling used in the manufacture, processing, packing, or holding of drug products. The specifications shall include a description of the sampling and testing procedures used. Samples shall be representative and adequately identified. Such procedures shall also require appropriate retesting of any component, drug product container, or closure that is subject to deterioration. (2) Determination of conformance to written specifications and a description of sampling and testing procedures for in-process materials. Such samples shall be representative and properly identified. (3) Determination of conformance to written descriptions of sampling procedures and appropriate specifications for drug products. Such samples shall be representative and properly identified. (4) The calibration of instruments, apparatus, gauges, and recording devices at suitable intervals in accordance with an established written program containing specific directions, schedules, limits for accuracy and precision, and provisions for remedial action in the event accuracy and/or precision limits are not met. Instruments, apparatus, gauges, and recording devices not meeting established specifications shall not be used.” 21 CFR 211.165(a) states, in part, that “For each batch of drug product, there shall be appropriate laboratory determination of satisfactory conformance to final specifications for the drug product, including the identity and strength of each active ingredient, prior to release * * *.” 21 CFR 211.165(e) states that “The accuracy, sensitivity, specificity, and reproducibility of test methods employed by the firm shall be established and documented. Such validation and documentation may be accomplished in accordance with § 211.194(a)(2).” 21 CFR 211.167(a) states that “For each batch of drug product purporting to be sterile and/or pyrogen-free, there shall be appropriate laboratory testing to determine conformance to such requirements. The test procedures shall be in writing and shall be followed.” 21 CFR 211.180(e) states, in part, that “Written records required by this part shall be maintained so that data therein can be used for evaluating, at least annually, the quality standards of each drug product to determine the need for changes in drug product specifications or manufacturing or control procedures * * *.” 21 CFR 211.192 states that “All drug product production and control records, including those for packaging and labeling, shall be reviewed and approved by the quality control unit to determine compliance with all established, approved written procedures before a batch is released or distributed. Any unexplained discrepancy (including a percentage of theoretical yield exceeding the maximum or minimum percentages established in master production and control records) or the failure of a batch or any of its components to meet any of its specifications shall be thoroughly investigated, whether or not the batch has already been distributed. The investigation shall extend to other batches of the same drug product and other drug products that may have been associated with the specific failure or discrepancy. A written record of the investigation shall be made and shall include the conclusions and followup.” --- PAGE 42 --- Contains Nonbinding Recommendations Certain aspects of sterility testing are of particular importance, including control of the testing environment, understanding the test limitations, and investigating manufacturing systems following a positive test. The testing laboratory environment should employ facilities and controls comparable to those used for aseptic filling operations. Poor or deficient sterility test facilities or controls can result in test failure. If production facilities and controls are significantly better than those for sterility testing, the danger exists of mistakenly attributing a positive sterility test result to a faulty laboratory even when the product tested could have, in fact, been nonsterile. Therefore, a manufacturing deficiency may go undetected. The use of isolators for sterility testing minimizes the chance of a false positive test result. A. Microbiological Laboratory Controls Sterility testing methods are required to be accurate and reproducible, in accordance with 211.194 and 211.165. USP <71> “Sterility Tests” is the principal source used for sterility testing methods, including information on test procedures and media.21 As a part of methods validation, appropriate microbiological challenge testing will demonstrate reproducibility of the method to reliably recover representative microorganisms. If growth is inhibited, modifications (e.g., increased dilution, additional membrane filter washes, addition of inactivating agents) to the test method should be implemented to optimize recovery. Ultimately, methods validation studies should demonstrate that the method does not provide an opportunity for false negatives. It is essential that the media used to perform sterility testing be rendered sterile and demonstrated as growth promoting. Personnel performing sterility testing should be qualified and trained for the task. A written program should be in place to maintain updated training of personnel and confirm acceptable sterility testing practices. B. Sampling and Incubation Sterility tests are limited in their ability to detect contamination because of the small sample size typically used. For example, as described by USP, statistical evaluations indicate that the sterility test sampling plan "only enables the detection of contamination in a lot in which 10% of the units are contaminated about nine times out of ten in making the test" (Ref. 13). To further illustrate, if a 10,000-unit lot with a 0.1 percent contamination level was sterility tested using 20 units, there is a 98 percent chance that the batch would pass the test. It is important that the samples represent the entire batch and processing conditions. Samples should be taken: • at the beginning, middle, and end of the aseptic processing operation • in conjunction with processing interventions or excursions . --- PAGE 43 --- Contains Nonbinding Recommendations Because of the limited sensitivity of the test, any positive result is considered a serious CGMP issue that should be thoroughly investigated. C. Investigation of Sterility Positives Care should be taken in the performance of the sterility test to preclude any activity that allows for possible sample contamination. When microbial growth is observed, the lot should be considered nonsterile and an investigation conducted. An initial positive test would be invalid only in an instance in which microbial growth can be unequivocally ascribed to laboratory error. Only if conclusive and documented evidence clearly shows that the contamination occurred as part of testing should a new test be performed. When available evidence is inconclusive, batches should be rejected as not conforming to sterility requirements. After considering all relevant factors concerning the manufacture of the product and testing of the samples, the comprehensive written investigation should include specific conclusions and identify corrective actions. The investigation's persuasive evidence of the origin of the contamination should be based on at least the following: 1. Identification (speciation) of the organism in the sterility test Sterility test isolates should be identified to the species level. Microbiological monitoring data should be reviewed to determine if the organism is also found in laboratory and production environments, personnel, or product bioburden. Advanced identification methods (e.g., nucleic- acid based) are valuable for investigational purposes. When comparing results from environmental monitoring and sterility positives, both identifications should be performed using the same methodology. 2. Record of laboratory tests and deviations Review of laboratory deviation and investigation findings can help to eliminate or implicate the laboratory as the source of contamination. For example, if the organism is seldom found in the laboratory environment, product contamination is more likely than laboratory error. If the organism is found in laboratory and production environments, it can still indicate product contamination. The proper handling of deviations is an essential aspect of laboratory control. When a deviation occurs during sterility testing, it should be documented, investigated, and remedied. If any deviation is considered to have compromised the integrity of the sterility test, the test should be invalidated immediately without incubation. A sterility positive result can be viewed as indicative of production or laboratory problems, and the entire manufacturing process should be comprehensively investigated since such problems often can extend beyond a single batch. To more accurately monitor potential contamination sources, we recommend keeping separate trends by appropriate categories such as product, container type, filling line, sampling, and testing personnel. Where the degree of sterility test --- PAGE 44 --- Contains Nonbinding Recommendations sample manipulation is similar for a terminally sterilized product and an aseptically processed product, a higher rate of initial sterility failures for the latter should be taken as indicative of aseptic processing production problems. Microbial monitoring of the aseptic area of the laboratory and personnel can also reveal trends that are informative. Upward trends in the microbial load in the aseptic area of the laboratory should be promptly investigated as to cause, and corrected. In some instances, such trends can appear to be more indicative of laboratory error as a possible source of a sterility test failure. Where a laboratory has a good track record with respect to errors, this history can lower suspicion of the lab as a source of contamination since chances are higher that the contamination arose from production. However, the converse is not true. Specifically, where a laboratory has a poor track record, firms should not assume that the contamination is automatically more attributable to the laboratory and consequently overlook a genuine production problem. Accordingly, it is essential that all sterility positives be thoroughly investigated. 3. Monitoring of production area environment Trend analysis of microorganisms in the critical and immediately adjacent areas is especially helpful in determining the source of contamination in a sterility failure investigation. Consideration of environmental microbial data should not be limited to results of monitoring the production environment for the lot, day, or shift associated with the suspect lot. For example, results showing little or no recovery of microorganisms can be misleading, especially when preceded or followed by a finding of an adverse trend or atypically high microbial counts. It is therefore important to look at both short- and long-term environmental trend analyses. 4. Monitoring Personnel The review of data and associated trends from daily monitoring of personnel can provide important information indicating a route of contamination. The adequacy of personnel practices and training also merit significant review and consideration. 5. Product Presterilization Bioburden We recommend review of trends in product bioburden and consideration of whether adverse bioburden trends have occurred. 6. Production record review Complete batch and production control records should be reviewed to detect any signs of failures or anomalies that could have a bearing on product sterility. For example, the investigation should include elements such as: • Events that could have impacted on the critical zone • Batch and trending data that indicate whether utility and/or support systems are functioning properly. For instance, records of air quality monitoring for filling lines --- PAGE 45 --- Contains Nonbinding Recommendations could show a time at which there was improper air balance or an unusually high particle count. • Whether construction or maintenance activities could have had an adverse impact 7. Manufacturing history The manufacturing history of a product or similar products should be reviewed as part of the investigation. Past deviations, problems, or changes (e.g., process, components, equipment) are among the factors that can provide an indication of the origin of the problem. --- PAGE 46 --- Contains Nonbinding Recommendations XII. BATCH RECORD REVIEW: PROCESS CONTROL DOCUMENTATION 21 CFR 211.100(a) states that “There shall be written procedures for production and process control designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess. Such procedures shall include all requirements in this subpart. These written procedures, including any changes, shall be drafted, reviewed, and approved by the appropriate organizational units and reviewed and approved by the quality control unit.” 21 CFR 211.100(b) states that “Written production and process control procedures shall be followed in the execution of the various production and process control functions and shall be documented at the time of performance. Any deviation from the written procedures shall be recorded and justified.” 21 CFR 211.186 and 211.188 address, respectively, "Master production and control records" and "Batch production and control records." 21 CFR 211.192 states that “All drug product production and control records, including those for packaging and labeling, shall be reviewed and approved by the quality control unit to determine compliance with all established, approved written procedures before a batch is released or distributed. Any unexplained discrepancy (including a percentage of theoretical yield exceeding the maximum or minimum percentages established in master production and control records) or the failure of a batch or any of its components to meet any of its specifications shall be thoroughly investigated, whether or not the batch has already been distributed. The investigation shall extend to other batches of the same drug product and other drug products that may have been associated with the specific failure or discrepancy. A written record of the investigation shall be made and shall include the conclusions and followup.” Manufacturers should build process and environmental control activities into their aseptic processing operation. It is critical that these activities be maintained and strictly implemented on a daily basis. The requirement for review of all batch records and data for conformance with written procedures, operating parameters, and product specifications prior to arriving at the final release decision for an aseptically processed product calls for an overall review of process and system performance for that given cycle of manufacture. All in-process and laboratory control results must be included with the batch record documentation in accordance with section 211.188. Review of environmental and personnel monitoring data, as well as other data relating to acceptability of output from support systems (e.g., HEPA / HVAC, WFI, steam generator) and proper functioning of equipment (e.g., batch alarms report; integrity of various filters) are considered essential elements of the batch release decision. While interventions and/or stoppages are normally recorded in the batch record, the manner of documenting these occurrences varies. In particular, line stoppages and any unplanned interventions should be sufficiently documented in batch records with the associated time and duration of the event. In addition to lengthened dwell time of sterile product elements in the critical area, an extensive intervention can increase contamination risk. Sterility failures have often been attributed to atypical or extensive interventions that have occurred as a response to an undesirable event during the aseptic process. Written procedures describing the need for line clearances in the event of certain interventions, such as machine adjustments and any repairs, should be established. Such interventions should be documented with more detail than minor events. Interventions that result in substantial activity near exposed product or container closures --- PAGE 47 --- Contains Nonbinding Recommendations or that last beyond a reasonable exposure time should, where appropriate, result in a local or full line clearance. Any disruption in power supply, however momentary, that could affect product quality is a manufacturing deviation and must be included in batch records (211.100, 211.192). --- PAGE 48 --- Contains Nonbinding Recommendations ## APPENDIX 1: ASEPTIC PROCESSING ISOLATORS Aseptic processing using isolation systems separates the external cleanroom environment from the aseptic processing line and minimizes its exposure to personnel. A well-designed positive pressure isolator, supported by adequate procedures for its maintenance, monitoring, and control, offers tangible advantages over traditional aseptic processing, including fewer opportunities for microbial contamination during processing. However, users should remain vigilant to potential sources of operational risk. Manufacturers should also be aware of the need to establish new procedures addressing issues unique to isolators. A. Maintenance 1. General Maintenance of isolator systems differs in some significant respects from the traditional, non- isolated aseptic processing operations. Although no isolator forms an absolute seal, very high integrity can be achieved in a well-designed unit. However, a leak in certain components of the system can constitute a significant breach of integrity. The integrity of gloves, half-suits, and seams should receive daily attention and be addressed by a comprehensive preventative maintenance program. Replacement frequencies should be established in written procedures that ensure parts will be changed before they breakdown or degrade. Transfer systems, gaskets, and seals are among the other parts that should be covered by the maintenance program. 2. Glove Integrity A faulty glove or sleeve (gauntlet) assembly represents a route of contamination and a critical breach of isolator integrity. A preventative maintenance program should be established. The choice of durable glove materials, coupled with a well-justified replacement frequency, are key aspects of good manufacturing practice to be addressed. With every use, gloves should be visually evaluated for any macroscopic physical defect. Physical integrity tests should also be performed routinely. A breach in glove integrity can be of serious consequence. The monitoring and maintenance program should identify and eliminate any glove lacking integrity and minimize the possibility of placing a sterile product at risk. Due to the potential for microbial migration through microscopic holes in gloves and the lack of a highly sensitive glove integrity test, we recommend affording attention to the sanitary quality of the inner surface of the installed glove and to integrating the use of a second pair of thin gloves. B. Design 1. Airflow There are two types of aseptic processing isolators: open and closed. Closed isolators employ connections with auxiliary equipment for material transfer. Open isolators have openings to the --- PAGE 49 --- Contains Nonbinding Recommendations surrounding environment that are carefully engineered to segregate the inner isolator environment from the surrounding room via overpressure. Turbulent flow can be acceptable within closed isolators, which are normally compact in size and do not house processing lines. Other aseptic processing isolators employ unidirectional airflow that sweeps over and away from exposed sterile materials, avoiding any turbulence or stagnant airflow in the area of exposed sterilized materials, product, and container closures. In most sound designs, air showers over the critical area once and then is systematically exhausted from the enclosure. The air handling system should be capable of maintaining the requisite environmental conditions within the isolator. 2. Materials of Construction As in any aseptic processing design, suitable materials should be chosen based on durability, as well as ease of cleaning and decontamination. For example, rigid wall construction incorporating stainless steel and glass materials is widely used. 3. Pressure Differential Isolators that include an open portal should be designed to ensure complete physical separation from the external environment. A positive air pressure differential adequate to achieve this separation should be employed and supported by qualification studies. Positive air pressure differentials from the isolator to the surrounding environment have largely ranged from approximately 17.5 to 50 Pascals.22 The appropriate minimum pressure differential established by a firm will depend on the system’s design and, when applicable, its exit port. Air balance between the isolator and other direct interfaces (e.g., dry heat tunnel) should also be qualified. The positive pressure differential should be coupled with an appropriately designed opening to the external environment to prevent potential ingress of surrounding room air by induction. Induction can result from local turbulent flow causing air swirls or pressure waves that might push extraneous particles into the isolator. Local Class 100 (ISO 5) protection at an opening is an example of a design provision that can provide a further barrier to the external environment. 4. Clean Area Classifications The interior of the isolator should meet Class 100 (ISO 5) standards. The classification of the environment surrounding the isolator should be based on the design of its interfaces (e.g., transfer ports), as well as the number of transfers into and out of the isolator. A Class 100,000 (ISO 8) background is commonly used based on consideration of isolator design and manufacturing situations. An aseptic processing isolator should not be located in an unclassified room. C. Transfer of Materials/Supplies 22 0.07” to 0.20” water gauge --- PAGE 50 --- Contains Nonbinding Recommendations The ability to maintain integrity of a decontaminated isolator can be affected impacted by the design of transfer ports. Various adaptations, of differing capabilities, allow for the transfer of supplies into and out of the isolator. Multiple material transfers are generally made during the processing of a batch. Frequently, transfers are performed via direct interface with manufacturing equipment. Properly maintained and operated rapid transfer ports (RTPs) are an effective transfer mechanism for aseptic transfer of materials into and out of isolators. Some transfer ports might have significant limitations, including marginal decontaminating capability (e.g., ultraviolet) or a design that has the potential to compromise isolation by allowing ingress of air from the surrounding room. In the latter case, localized HEPA-filtered unidirectional airflow cover in the area of such a port should be implemented. Isolators often include a mousehole or other exit port through which product is discharged, opening the isolator to the outside environment. Sufficient overpressure should be supplied and monitored on a continuous basis at this location to ensure that isolation is maintained. D. Decontamination 1. Surface Exposure Decontamination procedures should ensure full exposure of all isolator surfaces to the chemical agent. The capability of a decontaminant to penetrate obstructed or covered surfaces is limited. For example, to facilitate contact with the decontaminant, the glove apparatus should be fully extended with glove fingers separated during the decontamination cycle. It is also important to clean the interior of the isolator per appropriate procedures to allow for a robust decontamination process. 2. Efficacy The decontamination method should render the inner surfaces of the isolator free of viable microorganisms. Multiple available vaporized agents are suitable for achieving decontamination. Process development and validation studies should include a thorough determination of cycle capability. The characteristics of these agents generally preclude the reliable use of statistical methods (e.g., fraction negative) to determine process lethality (Ref. 13). An appropriate, quantified Biological Indicator (BI) challenge should be placed on various materials23 and in many locations throughout the isolator, including difficult to reach areas. Cycles should be developed with an appropriate margin of extra kill to provide confidence in robustness of the decontamination processes. Normally, a four- to six-log reduction can be justified depending on the application. The specific BI spore titer used and the selection of BI placement sites should be justified. For example, demonstration of a four-log reduction should be sufficient for controlled, very low bioburden materials introduced into a transfer isolator, including wrapped sterile supplies that are briefly exposed to the surrounding cleanroom environment. 23 If the various isolator materials are thoroughly evaluated during cycle development, a firm might consider placing more focus on material texture and porosity during validation of the decontamination process. --- PAGE 51 --- Contains Nonbinding Recommendations The uniform distribution of a defined concentration of decontaminating agent should also be evaluated as part of these studies (Ref. 14). Chemical indicators may also be useful as a qualitative tool to show that the decontaminating agent reached a given location. 3. Frequency The design of the interior and content of an isolator should provide for its frequent decontamination. When an isolator is used for multiple days between decontamination cycles, the frequency adopted should be justified. This frequency, established during validation studies, should be reevaluated and increased if production data indicate deterioration of the microbiological quality of the isolator environment. A breach of isolator integrity should normally lead to a decontamination cycle. Integrity can be affected by power failures, valve failure, inadequate overpressure, holes in gloves and seams, or other leaks. Breaches of integrity should be investigated. If it is determined that the environment may have been compromised, any product potentially impacted by the breach should be rejected. E. Filling Line Sterilization To ensure sterility of product contact surfaces from the start of each operation, the entire path of the sterile processing stream should be sterilized. In addition, aseptic processing equipment or ancillary supplies to be used within the isolator should be chosen based on their ability to withstand steam sterilization (or equivalent method). It is expected that materials that permit heat sterilization (e.g., SIP) will be rendered sterile by such methods. Where decontamination methods are used to render certain product contact surfaces free of viable organisms, a minimum of a six-log reduction should be demonstrated using a suitable biological indicator. F. Environmental Monitoring An environmental monitoring program should be established that routinely ensures acceptable microbiological quality of air, surfaces, and gloves (or half-suits) as well as particle levels, within the isolator. Nutrient media should be cleaned off of surfaces following a contact plate sample. Air quality should be monitored periodically during each shift. For example, we recommend monitoring the exit port for particles to detect any unusual results. Media used for environmental monitoring should not be exposed to decontamination cycle residues, as recovery of microorganisms would be inhibited. G. Personnel Although cleanroom apparel considerations are generally reduced in an isolator operation, the contamination risk contributed by manual factors can not be overlooked. Isolation processes generally include periodic or even frequent use of one or more gloves for aseptic manipulations and handling of material transfers into and out of the isolator. One should be aware that locations on gloves, sleeves, or half suits can be among the more difficult to reach places during decontamination, and glove integrity defects might not be promptly detected. Traditional aseptic processing vigilance remains critical, with an understanding that contaminated isolator gloves --- PAGE 52 --- Contains Nonbinding Recommendations can lead to product nonsterility. Accordingly, meticulous aseptic technique standards must be observed (211.113), including appropriate use of sterile tools for manipulations. --- PAGE 53 --- Contains Nonbinding Recommendations ## APPENDIX 2: BLOW-FILL- SEAL TECHNOLOGY Blow-fill-seal (BFS) technology is an automated process by which containers are formed, filled, and sealed in a continuous operation. This manufacturing technology includes economies in container closure processing and reduced human intervention and is often used for filling and packaging ophthalmics, respiratory care products, and, less frequently, injectables. This ## appendix discusses: some of the critical control points of this technology. Except where otherwise noted below, the aseptic processing standards discussed elsewhere in this document should apply to blow-fill-seal technology. A. Equipment Design and Air Quality Most BFS machines operate using the following steps. • Heat a plastic polymer resin • Extrude it to form a parison (a tubular form of the hot resin) • Cut the parison with a high-temperature knife • Move the parison under the blow-fill needle (mandrel) • Inflate it to the shape of the mold walls • Fill the formed container with the liquid product • Remove the mandrel • Seal Throughout this operation, sterile-air is used, for example, to form the parison and inflate it prior to filling. In most operations, the three steps with the greatest potential for exposure to particle contamination and/or surrounding air are those in which (1) the parison is cut, (2) the parison is moved under the blow-fill mandrel, and (3) the mandrel is removed (just prior to sealing). BFS machinery and its surrounding barriers should be designed to prevent the potential for extraneous contamination. As with any aseptic processing operation, it is critical that product contact surfaces be sterile. A validated steam-in-place cycle, or equivalent process, should be used to sterilize the equipment path through which the product is conveyed. In addition, any other surface that represents a potential contamination risk to the sterile product should be sterile. The classified environment surrounding BFS machinery should generally meet Class 100,000 (ISO 8), or better, standards, depending on the design of the BFS machinery and the surrounding room. HEPA-filtered or sterile air provided by membrane filters should be used during the steps when sterile products or materials are exposed (e.g., parison formation, container molding or filling steps). Air in the critical area should meet Class 100 (ISO 5) microbiological standards during operations. A well-designed BFS system should also normally achieve Class 100 (ISO 5) airborne particle levels. Only personnel who have been qualified and appropriately gowned should enter the classified environment surrounding the BFS machinery. Refer to Section V of this document for guidance on personnel training, qualification, and monitoring. BFS equipment design typically calls for use of specialized measures to reduce particle levels that can contaminate the exposed product. In contrast to nonpharmaceutical applications using --- PAGE 54 --- Contains Nonbinding Recommendations BFS machinery, control of air quality (i.e., particles) is critical for sterile drug product manufacture. Particles generated during the plastic extrusion, cutting, and sealing processes should be controlled. Provisions for carefully controlled airflow can protect the product by forcing generated particles outward while preventing any ingress from the adjacent environment. Furthermore, equipment designs that separate the filling zone from the surrounding environment provide additional product protection. Barriers, pressure vacuums, microenvironments, and appropriately directed high velocities of sterile air have been found useful in preventing contamination (Ref. 15). Smoke studies and multi-location particle data can provide valuable information when performing qualification studies to assess whether proper particle control dynamics have been achieved throughout the critical area. In addition to suitable design, it is important to establish an adequate preventative maintenance program. For example, because of its potential to contaminate the sterile drug product, the integrity of the cooling, heating and other utility systems associated with the BFS machine should be maintained and routinely monitored. B. Validation/Qualification Advantages of BFS processing are known to include rapid container closure processing and minimized aseptic interventions. However, only a properly functioning process can realize these advantages. We recommend affording special attention to setup, troubleshooting of equipment, and related aseptic personnel procedures. Equipment sterilization, media fills, polymer extrusion/sterilization, product-plastic compatibility, forming and sealing integrity, and unit weight variation are among the key issues to address in validation and qualification studies. Data gathered during such studies should ensure that BFS containers are sterile and, if used for parenteral drugs, nonpyrogenic. This can generally be achieved by validating that time temperature conditions of the extrusion process are effective against endotoxin or spore challenges in the polymeric material. The choice of appropriate polymer material for a BFS operation includes assessing if a material is pharmaceutical grade, safe, pure, and passes appropriate criteria (Ref. 17) for plastics. Polymer suppliers should be qualified and monitored for raw material quality. C. Batch Monitoring and Control Various in-process control parameters (e.g., container weight variation, fill weight, leakers, air pressure) provide information to monitor and facilitate ongoing process control. It is essential to monitor the microbial air quality. Samples should be taken according to a comprehensive sampling plan that provides data representative of the entire filling operation. Continuous monitoring of particles can provide valuable data relative to the control of a blow-fill-seal operation. Container closure defects can be a major problem in control of a BFS operation. It is critical that the operation be designed and set-up to uniformly manufacture integral units. As a final measure, the inspection of each unit of a batch should include a reliable, sensitive, final product examination that is capable of identifying defective units (e.g., leakers). Significant defects due --- PAGE 55 --- Contains Nonbinding Recommendations to heat or mechanical problems, such as wall thickness, container or closure interface deficiencies, poorly formed closures, or other deviations should be investigated in accordance with §§ 211.100 and 211.192. --- PAGE 56 --- Contains Nonbinding Recommendations ## APPENDIX 3: PROCESSING PRIOR TO FILLING AND SEALING OPERATIONS The purpose of this appendix is to supplement the guidance provided in this document with information on products regulated by CBER or CDER that are subject to aseptic processing at points early in the manufacturing process, or that require aseptic processing through the entire manufacturing process because it is impossible to sterile filter the final drug product. The scope of this appendix includes aseptic processing activities that take place prior to the filling and sealing of the finished drug product. Special considerations include those for: A. Aseptic processing from early manufacturing steps Some products undergo aseptic processing at some or all manufacturing steps preceding the final product closing step. With other products, there is a point in the process after which they can no longer be rendered sterile by filtration. In such cases, the product would be handled aseptically at all steps subsequent to sterile filtration. In other instances, the final drug product cannot be sterile-filtered and, therefore, each component in the formulation would be rendered sterile and mixed aseptically. For example, products containing aluminum adjuvant are formulated aseptically because once they are alum adsorbed, they cannot be sterile-filtered. When a product is processed aseptically from the early stages, the product and all components or other additions are rendered sterile prior to entering the manufacturing process. It is critical that all transfers, transports, and storage stages be carefully controlled at each step of the process to maintain sterility of the product. In some cases, bulk drug substances or products should be tested for sterility.24 Procedures (e.g., aseptic connection) that expose a product or product contact surfaces should be performed under unidirectional airflow in a Class 100 (ISO 5) environment. The environment of the room surrounding the Class 100 (ISO 5) environment should be Class 10,000 (ISO 7) or better. Microbiological and airborne particle monitoring should be performed during operations. Microbial surface monitoring should be performed at the end of operations, but prior to cleaning. Personnel monitoring should be performed in association with operations. Process simulation studies covering the steps preceding filling and sealing should be designed to incorporate all conditions, product manipulations, and interventions that could impact on the sterility of the product. The process simulation, from the early process steps, should demonstrate that process controls are adequate to protect the product during manufacturing. These studies should incorporate all product manipulations, additions, and procedures involving exposure of product contact surfaces to the environment. The studies should include worst-case conditions such as maximum duration of open operations and maximum number of participating operators. However, the process simulations do not need to mimic total manufacturing time if the manipulations that occur during manufacturing are adequately represented. It is also important that process simulations incorporate storage of sterile bulk drug substances or product and transport to other manufacturing areas. For instance, there should be assurance of bulk vessel integrity for specified holding times. The transport of sterile bulk tanks or other containers should be simulated as part of the media fill. Please refer to Section IX.A for more 24 See 21 CFR 610.12 for general biological product standards for sterility. --- PAGE 57 --- Contains Nonbinding Recommendations guidance on media simulation studies. Process simulation studies for the formulation stage should be performed at least twice per year. B. Aseptic processing of cellular therapy products and cell-derived products Cellular therapy and some cell-derived products (e.g., lysates, semi-purified extracts) represent a subset of the products that cannot be filter-sterilized and therefore undergo aseptic manipulations throughout the manufacturing process. Where possible, closed systems should be used during manufacturing. Cellular therapy products often have short processing times at each manufacturing stage, particularly between the harvest, formulation of the final product, and product release. These products are frequently released from the manufacturing facility and administered to patients before final product sterility testing results are available. In situations where results of final sterility testing are not available before the product is administered, additional controls and testing should be considered. For example, additional sterility tests can be performed at intermediate stages of manufacture, such as after the last manipulation of the product prior to harvest. Other tests that may indicate microbial contamination, such as microscopic examination, Gram stain (or other bacterial and fungal stain), and endotoxin testing should be performed and meet acceptance criteria prior to product release. --- PAGE 58 --- Contains Nonbinding Recommendations REFERENCES 1. ISO 14644-1: Cleanrooms and Associated Controlled Environments, Classification of Air Cleanliness. 2. NASA Standard for Cleanroom and Work Stations for Microbially Controlled Environment, Publication NHB 5340.2 (August l967). 3. Technical Order 00-25-203, Contamination Control of Aerospace Facilities, U.S. Air Force, December l, l972. 4. Ljungqvist, B., and Reinmuller, B., Cleanroom Design: Minimizing Contamination Through Proper Design; Interpharm Press, 1997. 5. Lord, A. and J. W. Levchuk, "Personnel Issues in Aseptic Processing," Biopharm, 1989. 6. Morbidity and Mortality Weekly Report, "Clinical Sepsis and Death in a Newborn Nursery Associated with Contaminated Medications" – Brazil, 1996, Centers for Disease Control and Prevention, July, 1998; 47(29);610-2. 7. Grandics, Peter, “Pyrogens in Parenteral Pharmaceuticals,” Pharmaceutical Technology, April 2000. 8. Recommendations of PQRI Aseptic Processing Working Group, Product Quality Research Institute; March, 2003. 9. Technical Report No. 36, “Current Practices in the Validation of Aseptic Processing," Parenteral Drug Association, Inc., 2002. 10. Leahy, T. J. and M. J. Sullivan, “Validation of Bacterial - Retention Capabilities of Membrane Filters," Pharmaceutical Technology, Nov., l978. 11. Pall, D. B. and E. A. Kirnbauer, et al., "Particulate Retention by Bacteria Retentive Membrane Filters," Pall Corporation Colloids and Surfaces, l (l980) 235-256, Elsevier Scientific Publishing Company, Amsterdam. 12. Technical Report No. 26, "Sterilizing Filtration of Liquids," Parenteral Drug Association, Inc., 1998. 13. Sigwarth, V. and A. Stark, “Effect of Carrier Materials on the Resistance of Spores of Bacillus stearothermophilus to Gaseous Hydrogen Peroxide,” PDA Journal of Pharmaceutical Science and Technology, Vol. 57, No. 1, January/February 2003. 14. Isolators used for Aseptic Processing and Sterility Testing, Pharmaceutical Inspection Convention Cooperation Scheme (PIC/S); June, 2002. 15. Price, J., “Blow-Fill-Seal Technology: Part I, A Design for Particulate Control,” Pharmaceutical Technology, February, 1998. 16. United States Pharmacopoeia --- PAGE 59 --- Contains Nonbinding Recommendations RELEVANT GUIDANCE DOCUMENTS Some relevant FDA guidance documents include: Guidance for the Submission of Documentation for Sterilization Process Validation in Applications for Human and Veterinary Drug Products Guideline for Validation of Limulus Amebocyte Lysate Test as an End Product Endotoxin Test for Human and Animal Parenteral Drugs, Biological Products, and Medical Devices Guide to Inspections of Lyophilization of Parenterals Guide to Inspections of High Purity Water Systems Guide To Inspections of Microbiological Pharmaceutical Quality Control Laboratories Guide To Inspections of Sterile Drug Substance Manufacturers Pyrogens: Still a Danger; (Inspection Technical Guide) Bacterial Endotoxins/Pyrogens; (Inspection Technical Guide) Heat Exchangers to Avoid Contamination; (Inspection Technical Guide) Compliance Program Guidance Manual 7356.002 A, Sterile Drug Process Inspections ICH Q5A, Guidance on Viral Safety Evaluation of Biotechnology Products Derived from Cell Lines of Human or Animal Origin See also the draft guidance Container and Closure Integrity Testing in Lieu of Sterility Testing as a Component of the Stability Protocol for Sterile Products, which was issued in 1998. Once final, it will represent the Agency's thinking on this topic. --- PAGE 60 --- Contains Nonbinding Recommendations GLOSSARY Air lock- A small room with interlocked doors, constructed to maintain air pressure control between adjoining rooms (generally with different air cleanliness standards). The intent of an aseptic processing airlock is to preclude ingress of particulate matter and microorganism contamination from a lesser controlled area. Alert Level- An established microbial or airborne particle level giving early warning of potential drift from normal operating conditions and triggers appropriate scrutiny and follow-up to address the potential problem. Alert levels are always lower than action levels. Action Level- An established microbial or airborne particle level that, when exceeded, should trigger appropriate investigation and corrective action based on the investigation. Aseptic Manufacturing Area- The classified part of a facility that includes the aseptic processing room and ancillary cleanrooms. For purposes of this document, this term is synonymous with “aseptic processing facility” as used in the segregated segment context. Aseptic Processing Facility- A building, or segregated segment of it, containing cleanrooms in which air supply, materials, and equipment are regulated to control microbial and particle contamination. Aseptic Processing Room- A room in which one or more aseptic activities or processes is performed. Asepsis- A state of control attained by using an aseptic work area and performing activities in a manner that precludes microbiological contamination of the exposed sterile product. Bioburden- The total number of microorganisms associated with a specific item prior to sterilization. Barrier- A physical partition that affords aseptic processing area (ISO 5) protection by partially separating it from the surrounding area. Biological Indicator (BI)- A population of microorganisms inoculated onto a suitable medium (e.g., solution, container or closure) and placed within appropriate sterilizer load locations to determine the sterilization cycle efficacy of a physical or chemical process. The challenge microorganism is selected based upon its resistance to the given process. Incoming lot D-value and microbiological count define the quality of the BI. Clean Area- An area with defined particle and microbiological cleanliness standards. Cleanroom- A room designed, maintained, and controlled to prevent particle and microbiological contamination of drug products. Such a room is assigned and reproducibly meets an appropriate air cleanliness classification. --- PAGE 61 --- Contains Nonbinding Recommendations Component- Any ingredient intended for use in the manufacture of a drug product, including those that may not appear in the final drug product. Colony Forming Unit (CFU)- A microbiological term that describes the formation of a single macroscopic colony after the introduction of one or more microorganisms to microbiological growth media. One colony forming unit is expressed as 1 CFU. Critical Area - An area designed to maintain sterility of sterile materials. Sterilized product, containers, closures, and equipment may be exposed in critical areas. Clean Zone- See Clean Area. Critical surfaces- Surfaces that may come into contact with or directly affect a sterilized product or its containers or closures. Critical surfaces are rendered sterile prior to the start of the manufacturing operation, and sterility is maintained throughout processing. Decontamination- A process that eliminates viable bioburden via use of sporicidal chemical agents. Disinfection- Process by which surface bioburden is reduced to a safe level or eliminated. Some disinfection agents are effective only against vegetative microbes, while others possess additional capability to effectively kill bacterial and fungal spores. Depyrogenation- A process used to destroy or remove pyrogens (e.g., endotoxin). D value- The time (in minutes) of exposure at a given temperature that causes a one-log or 90 percent reduction in the population of a specific microorganism. Dynamic- Conditions relating to clean area classification under conditions of normal production. Endotoxin- A pyrogenic product (e.g., lipopolysaccharide) present in the bacterial cell wall. Endotoxin can lead to reactions in patients receiving injections ranging from fever to death. Gowning Qualification- A program that establishes, both initially and on a periodic basis, the capability of an individual to don the complete sterile gown in an aseptic manner. HEPA filter- High efficiency particulate air filter with minimum 0.3 µm particle retaining efficiency of 99.97 percent. HVAC- Heating, ventilation, and air conditioning. Intervention- An aseptic manipulation or activity that occurs at the critical area. Isolator- A decontaminated unit, supplied with Class 100 (ISO 5) or higher air quality, that provides uncompromised, continuous isolation of its interior from the external environment (e.g., surrounding cleanroom air and personnel). There are two major types of isolators: --- PAGE 62 --- Contains Nonbinding Recommendations Closed isolator systems exclude external contamination from the isolator’s interior by accomplishing material transfer via aseptic connection to auxiliary equipment, rather than use of openings to the surrounding environment. Closed systems remain sealed throughout operations. Open isolator systems are designed to allow for the continuous or semi-continuous ingress and/or egress of materials during operations through one or more openings. Openings are engineered (e.g., using continuous overpressure) to exclude the entry of external contamination into the isolator. Laminar flow- An airflow moving in a single direction and in parallel layers at constant velocity from the beginning to the end of a straight line vector. Operator- Any individual participating in the aseptic processing operation, including line set-up, filler, maintenance, or other personnel associated with aseptic line activities. Overkill sterilization process- A process that is sufficient to provide at least a 12 log reduction of microorganisms having a minimum D value of 1 minute. Pyrogen- A substance that induces a febrile reaction in a patient. Sterile Product- For purposes of this guidance, sterile product refers to one or more of the elements exposed to aseptic conditions and ultimately making up the sterile finished drug product. These elements include the containers, closures, and components of the finished drug product. Sterilizing grade filter- A filter that, when appropriately validated, will remove all microorganisms from a fluid stream, producing a sterile effluent. Quality Control Unit- An organizational element with authority and responsibility as defined by 211.22. Unidirectional flow- An airflow moving in a single direction, in a robust and uniform manner, and at sufficient speed to reproducibly sweep particles away from the critical processing or testing area. Terminal sterilization- The application of a lethal agent to sealed, finished drug products for the purpose of achieving a predetermined sterility assurance level (SAL) of usually less than 10-6 (i.e., a probability of a nonsterile unit of greater than one in a million). ULPA filter- Ultra-low penetration air filter with minimum 0.3 µm particle retaining efficiency of 99.999 percent. Validation- Establishing documented evidence that provides a high degree of assurance that a specific process will consistently produce a product meeting its predetermined specifications and quality attributes. --- PAGE 63 --- Contains Nonbinding Recommendations Worst case- A set of conditions encompassing upper and lower processing limits and circumstances, including those within standard operating procedures, that pose the greatest chance of process or product failure (when compared to ideal conditions). Such conditions do not necessarily induce product or process failure. --- ### Document: FDA CCIT Complete (FDA) # FDA Guidance for Industry: Container and Closure System Integrity Testing in Lieu of Sterility Testing as a Component of the Stability Protocol for Sterile Products (2008) Guidance for Industry Container and Closure System Integrity Testing in Lieu of Sterility Testing as a Component of the Stability Protocol for Sterile Products For questions on the content of the guidance, contact CBER’s Office of Compliance and Biologics Quality at 301-827-3031; CDER’s Office of Pharmaceutical Science at 301-796-1228; CDRH’s Office of Device Evaluation at 240-276-3747; or CVM’s Office of New Animal Drug Evaluation at 301-827-6963. U. S. Department of Health and Human Services Food and Drug Administration Center for Biologics Evaluation and Research Center for Drug Evaluation and Research Center for Devices and Radiological Health Center for Veterinary Medicine February 2008 Guidance for Industry Container and Closure System Integrity Testing in Lieu of Sterility Testing as a Component of the Stability Protocol for Sterile Products Additional copies of this guidance are available from: Office of Communication, Training and Manufacturers Assistance, HFM-40 Center for Biologics Evaluation and Research Food and Drug Administration 1401 Rockville Pike, Suite 200N, Rockville, MD 20852-1448 Internet: http://www.fda.gov/cber/guidelines.htm Phone: 800-835-4709 or 301-827-1800 or Office of Training and Communication Division of Drug Information, HFD-240 Center for Drug Evaluation and Research Food and Drug Administration 5600 Fishers Lane, Rockville, MD 20857 Phone: 301-827-4573 Internet: http://www.fda.gov/cder/guidance/index.htm or Division of Small Manufacturers, International, and Consumer Assistance (DSMICA), HFZ-220 Center for Devices and Radiological Health Food and Drug Administration 1350 Piccard Drive, Rockville, MD 20850 Phone: 800-638-2041 Internet: http://www.fda.gov/cdrh/guidance.html Email: dsmica@cdrh.fda.gov Fax: 240-276-3151 or Communications Staff, HFV-12 Center for Veterinary Medicine (CVM) Food and Drug Administration 7519 Standish Place Internet at http://www.fda.gov/cvm/guidance/published.htm Contains Nonbinding Recommendations Table of Contents I. PURPOSE AND SCOPE................................................................................................1 II. INTRODUCTION...........................................................................................................2 III. DEFINITIONS................................................................................................................3 IV. BACKGROUND .............................................................................................................3 V. ALTERNATIVES...........................................................................................................4 VI. IMPLEMENTATION ....................................................................................................5 VII. APPLICATION SUBMISSION ....................................................................................5 i Contains Nonbinding Recommendations GUIDANCE FOR INDUSTRY1 Container and Closure System Integrity Testing in Lieu of Sterility Testing as a Component of the Stability Protocol for Sterile Products This guidance represents the Food and Drug Administration’s (FDA’s) current thinking on this topic. It does not create or confer any rights for or on any person and does not operate to bind FDA or the public. You can use an alternative approach if the approach satisfies the requirements of the applicable statutes and regulations. If you want to discuss an alternative approach, contact the appropriate FDA staff. If you cannot identify the appropriate FDA staff, call the appropriate number listed on the title page of this guidance. I. PURPOSE AND SCOPE This guidance document provides recommendations to you, manufacturers, for using methods other than sterility testing to confirm container and closure system integrity as a part of the stability protocol for sterile biological products, human and animal drugs, and medical devices. This guidance document finalizes the draft guidance of the same title dated January 1998 (January 28, 1998, 63 Federal Register (FR) 4272). Manufacturers of drugs and biologics purporting to be sterile must test each batch or lot, as the case may be, to ensure that the product in question conforms to sterility requirements. 21 CFR 211.167(a); 21 CFR 610.12. Such drugs and biologics are also subject to stability testing requirements. 21 CFR 211.166. The stability testing requirements include maintaining a written testing program designed to assess stability characteristics. Manufacturers of medical devices must validate processes, including sterilization for a device purporting to be sterile. 21 CFR 820.75. Stability testing should be part of the design validation of such devices. In vitro diagnostic products for human use are required to be labeled with stability information. 21 CFR 809.10. For products labeled as sterile, we consider sterility to be a stability characteristic. The purpose of stability testing is to provide evidence on how the quality of a substance or product varies with time under the influence of a variety of environmental factors such as temperature, humidity, and light, which enables you to establish or modify recommended storage conditions, retest periods, and shelf life or dating period, as the case may be.2 This guidance document applies only to the replacement of the sterility test with an appropriate container and closure system integrity test in the stability written testing program (referred to in this guidance 1 This guidance document was prepared by an intercenter working group with representatives from the Center for Biologics Evaluation and Research, Center for Devices and Radiological Health, Center for Drug Evaluation and Research, and the Center for Veterinary Medicine. 2 "Dating period" being the term used for biologics, as defined at 21 CFR 600.3(l), and "shelf life" being the term used for other drugs. Contains Nonbinding Recommendations as the "stability protocol"), recommending an alternative to sterility testing for supporting the continued capability of containers to maintain sterility. The guidance document does not apply to sterility testing methods for product sterility testing prior to release, as container and closure system integrity tests cannot demonstrate a product's initial sterility. This guidance document provides information that we recommend you consider when you propose using alternative methods to sterility testing to confirm the integrity of a container and closure system throughout the product's shelf life or dating period. The recommendations in this guidance document apply to both pre- and post-approval stability protocols for sterile biological products, human and animal drugs, including investigational and bulk drugs. For medical devices, the recommendations in this guidance document apply to stability protocols for those devices labeled as sterile. If you currently perform sterility testing as a stability-indicating test as part of a stability protocol, you may continue to do so. If your product is approved for an alternative to sterility testing as a component of your stability protocol, this document is not intended to recommend additional testing requirements. FDA’s guidance documents, including this guidance, do not establish legally enforceable responsibilities. Instead, guidances describe the FDA’s current thinking on a topic and should be viewed only as recommendations, unless specific regulatory or statutory requirements are cited. The use of the word should in FDA’s guidances means that something is suggested or recommended, but not required. II. INTRODUCTION Products labeled as sterile are expected to be free from viable microbial contamination throughout the product's entire shelf life or dating period. For products labeled as sterile, we consider sterility to be a stability characteristic. As a result, the stability protocol should include confirmation of continuing sterility throughout the product's shelf life or dating period. The minimum sterility testing generally performed as a component of the stability protocol for sterile products is at the initial time point (release) and final testing interval (i.e., expiration). Additional testing is often performed at appropriate intervals within this time period (e.g., annually). However, as discussed below sterility tests for the purpose of demonstrating continuing sterility have limitations, with respect to the method's reliability, accuracy, and the conclusions that may be derived from the results. Because of the limitations of sterility tests described below, sterility tests are not recommended as a component of a stability program for confirming the continued sterility throughout a product's shelf life or dating period. Alternative methods may be more reliable in confirming the integrity of the container and closure system as a component of the stability protocol for sterile products. This guidance document does not suggest specific test methods and acceptance criteria (except for references to USP methods), nor does it provide comprehensive lists of tests. You should determine these details based on good scientific principles for each specific container and closure system taking into consideration particular product formulations and, where applicable, routes of administration. Contains Nonbinding Recommendations III. DEFINITIONS The definitions presented here are for the purposes of this guidance only. A container and closure system refers to the entirety of packaging components that together contain and protect the product. A packaging component means any single part of a container and closure system. Typical components are containers (e.g., ampules, vials, bottles), container liners, closures (e.g., screw caps, stoppers), closure liners, stopper overseals, container inner seals, administration ports (e.g., on large-volume parenterals), overwraps, administration accessories, and container labels. IV. BACKGROUND Sterility tests have long been used to verify that products maintain their sterility throughout the product's entire shelf life or dating period. However, sterility testing has scientific and practical limitations, which are well known. Some of these are: 1. Sterility tests will only detect viable microorganisms present at the time of the test; 2. Viable organisms present at the time of the test can only be detected if they are capable of growth in the specified culture media; 3. Sterility tests may be subject to potential interference due to adventitious microbial contamination introduced at the time of testing, resulting in false positive readings; and 4. Sterility tests are always destructive of the samples tested and do not offer the opportunity to reexamine the same samples in the event of either positive or negative findings. Some Centers of FDA have sought to address these shortcomings and communicated the information to you in the guidance document: "Guidance for Industry for the Submission Documentation for Sterilization Process Validation in Applications for Human and Veterinary Drug Products" (December 3, 1993, 58 FR 63996). Section V. A., page 16 of the guidance states: The ability of the container-closure system to maintain the integrity of its microbial barrier, and, hence, the sterility of a drug product throughout its shelf life, should be demonstrated. […] As previously stated, sterility testing at the initial time point is not considered sufficient to demonstrate the microbial integrity of a container-closure system. […]. In the Federal Register of July 10, 1996 (61 FR 36466), we published a notice regarding the final guideline entitled "Quality of Biotechnological Products: Stability Testing of Biotechnological/Biological Products", prepared under the auspices of the International Conference on Harmonization of Technical Requirements for Registration of Pharmaceuticals Contains Nonbinding Recommendations for Human Use (ICH Final Guideline).3 The ICH Final Guideline is intended to provide guidance to applicants regarding the type of stability studies that should be provided in support of marketing applications for biotechnological/biological products. 4 V. ALTERNATIVES Alternatives to sterility testing as part of the stability protocol, such as replacing the sterility test with container and closure system integrity testing, might include any properly validated physical or chemical container and closure system integrity test (e.g., bubble tests, pressure/vacuum decay, trace gas permeation/leak tests, dye penetration tests, seal force or electrical conductivity and capacitance tests, etc.), or microbiological container and closure system integrity tests (e.g., microbial challenge or immersion tests). Such tests may be more useful than sterility testing in demonstrating the potential for product contamination over the product’s shelf life or dating period. The advantages of using such container and closure system integrity tests in lieu of sterility tests in the stability protocol for sterile products include: 1. Such alternate methods may detect a breach of the container and/or closure system prior to product contamination; 2. Some of the alternate methods used to evaluate container and closure integrity can conserve samples that may be used for other stability tests; 3. Alternative test methods may require less time than sterility test methods which require at least seven days incubation; and 4. The potential for false positive results may be reduced with some alternative test methods when compared to sterility tests. 3 For veterinary products, generally, see: VICH GL17, "Stability Testing of New Biotechnological/Biological Veterinary Medicinal Products," 66 FR 19177, April 13, 2001, and VICH GL3(R), "Stability Testing of New Veterinary Drug Substances and Medicinal Products (Revision)," 71 FR 19525, April 14, 2006. 4 The ICH Final Guideline is intended to supplement the tripartite ICH guideline entitled, “Stability Testing of New Drug Substances and Products,” the notice for which is published in the Federal Register of September 22, 1994 (59 FR 48754). This guideline reflects formal scientific principles for stability testing of human drugs, and provides a general indication of the information to be generated on product stability, but leaves sufficient flexibility to encompass the variety of different practical approaches required for specific scientific situations and characteristics of the materials being evaluated. A revision of the September 22, 1994, ICH guideline with the same title (Q1A (R)) (66 FR 56332, November 7, 2001) was issued to add information to certain sections and to provide clarification to other sections. The most important changes were as follows: (1) stress testing of the drug substance was moved from the glossary to the main text; (2) the text on test procedures was made consistent with ICH guidance “Q6A Specifications: Test Procedures and Acceptance Criteria for New Drug Substances and New Drug Products: Chemical Substances” (65 FR 83041, December 29, 2000)), and relevant cross-references to other ICH guidelines were introduced; (3) the text on testing frequency was amended for accelerated testing conditions; (4) storage conditions are described in more detail, and testing at low temperature and testing of aqueous liquids in semipermeable containers are specifically addressed; (5) the postapproval commitment is clearly described; and (6) the guidance was made editorially consistent. A second revision of the guideline, “Guidance for Industry Q1A (R2) Stability Testing of New Drug Substances and Products,” (68 FR 65717, November 21, 2003) was issued to harmonize intermediate storage conditions for zones I and II with long-term storage conditions for zones III and IV. Contains Nonbinding Recommendations Occasionally, applicants have proposed the use of a preservative effectiveness test in lieu of the appropriate sterility test for products containing antimicrobial preservatives. However, these tests only measure the effectiveness of preservatives against a panel of five different test organisms. This method cannot confirm product sterility since it does not confirm the presence or absence of contamination, but rather only demonstrates the microbiological effectiveness of the preservative system against the five test organisms in question. For these reasons, preservative effectiveness tests are not acceptable alternative tests for monitoring container and closure system integrity or for demonstrating maintenance of sterility. However, such tests are appropriate to perform as part of the stability protocol on multi-dose containers at the end of the product's shelf life or dating period, to verify antimicrobial preservative effectiveness and preservative content. VI. IMPLEMENTATION When seeking to implement container and closure system integrity testing as an alternative to sterility testing as a component of the stability protocol for sterile products, we recommend that you consider the following: 1. A container and closure system integrity test may replace sterility testing in a stability program at time points other than the product sterility test prior to release; 2. Container and closure system integrity tests do not replace sterility testing methods for product sterility testing prior to release; 3. Any validated container and closure system integrity test method should be acceptable provided the method uses analytical detection techniques appropriate to the method and is compatible with the specific product being tested. A test method is adequately validated if it has been proven through scientifically accepted studies to be capable of detecting a breach in container and closure system integrity; and 4. An appropriate container and closure system integrity test should be conducted annually and at expiration, or as otherwise required by applicable regulations. VII. APPLICATION SUBMISSION For new marketing applications for sterile products, we recommend that you include container and closure system integrity tests in your stability protocol. Pending new marketing applications may be amended prior to approval. If you wish to incorporate a validated container and closure system integrity test to demonstrate the continued capability of containers to maintain sterility for an approved product,5 you must submit the appropriate application supplement, as follows: 5 As previously mentioned, if you currently perform sterility testing as a stability-indicating test as part of a stability protocol, you may continue to do so. Also, if your product is approved for an alternative to sterility testing as a component of your stability protocol, this document is not intended to impose additional testing requirements. Contains Nonbinding Recommendations Human drugs: Submit methods and data labeled “Special Supplement - Changes Being Effected” for new and abbreviated new drug applications under § 314.70. Animal drugs: Submit methods and data as “Supplement - Changes Being Effected” under § 514.8. Biological products: Submit a supplement with proper validation data in support of the proposed change as a “Supplement - Changes Being Effected” under § 601.12. Medical devices: Submit a PMA supplement with proper validation data in support of the proposed change under § 814.39. You should include in your application supplement a discussion of what the test method evaluates and how it is applicable to microbial integrity. You should select methods that are appropriate to the product in question, and validate all test methods. Validation of particular methods should be specific to the product container and closure system or product type. Several alternative container and closure system integrity test methods exist, as described above. We encourage you to develop innovative methods of testing the integrity of specific container and closure systems. The use of media-filled containers is generally acceptable for initial validation studies. It may be acceptable to use media-filled containers instead of product-filled containers for testing during the product's shelf life or dating period, if the product contains a material, such as a preservative, which would bias the results of the container and closure system integrity test. If you propose to use media-filled containers for some or all of the testing, you should include data in your application supplement to support this request. If you manufacture a number of products that use the same type of container and closure system, you may validate your integrity test method using a bracketing matrix.6 It is not necessary to perform validation studies on each product. The number of samples to be tested should be statistically appropriate. Samples which pass container and closure system integrity testing may be further utilized in the stability testing for that specific test period or interval; however, the test should be non-destructive and the sample unaltered by the container and closure testing method itself. Samples should not, however, be tested for container and closure system integrity at one time interval (e.g., 12 months), and then stored for further stability testing at later time periods (e.g., 24 months). 6 See ICH guidance “Q1D Bracketing and Matrixing Designs for Stability Testing of New Drug Substances and Products” (68 FR 2339, January 16, 2003). --- ### Document: FDA ComboProd CGMP Complete (FDA) # FDA Guidance: Current Good Manufacturing Practice Requirements for Combination Products (Jan 2017): Current Good Manufacturing Practice Requirements for Combination Products On February 2, 2024, FDA published the final rule to amend the Quality System (QS) regulation in 21 CFR part 820 (89 FR 7496, effective February 2, 2026). The revised 21 CFR part 820 is now titled the Quality Management System Regulation (QMSR). The QMSR harmonizes quality management system requirements by incorporating by reference the international standard specific for medical device quality management systems set by the International Organization for Standardization (ISO), ISO 13485:2016. The FDA has determined that the requirements in ISO 13485 are, when taken in totality, substantially similar to the requirements of the QS regulation, providing a similar level of assurance in a firm’s quality management system and ability to consistently manufacture devices that are safe and effective and otherwise in compliance with the Federal Food, Drug, and Cosmetic Act (FD&C Act). This guidance document was issued prior to the effective date of the final rule. FDA encourages manufacturers to review the current QMSR to ensure compliance with the relevant regulatory requirements. The QMSR includes conforming edits to 21 CFR part 4 subpart A, Current Good Manufacturing Practice Requirements for Combination Products, to clarify the device quality management system requirements for combination products. Guidance for Industry and FDA Staff: Current Good Manufacturing Practice Requirements for Combination Products FINAL GUIDANCE The draft of this document was issued in January 2015. Additional copies are available from: Office of Combination Products Food and Drug Administration WO32, Hub/Mail Room #5129 10903 New Hampshire Avenue Silver Spring, MD 20993 (Tel) 301-796-8930 (Fax) 301-847-8619 http://www.fda.gov/oc/combination For questions regarding this document, contact the Office of Combination Products at 301-796- 8930 or combination@fda.gov. U.S. Department of Health and Human Services Food and Drug Administration Office of Combination Products (OCP) in the Office of the Commissioner Center for Biologics Evaluation and Research (CBER) Center for Drug Evaluation and Research (CDER) Center for Devices and Radiological Health (CDRH) Office of Regulatory Affairs (ORA) January 2017 TABLE OF CONTENTS I. Introduction ............................................................................................................................ 3 II. Background ............................................................................................................................ 4 A. Definition of a combination product ............................................................................................ 4 B. Quality and Current Good Manufacturing Practices................................................................. 5 C. Overview of the final rule .............................................................................................................. 5 D. The role of the lead center and other agency components ......................................................... 9 III. General Considerations for CGMP Compliance .............................................................. 9 A. Demonstrating compliance .......................................................................................................... 10 B. Investigational products .............................................................................................................. 11 C. Definitions and terminology. ....................................................................................................... 12 D. What CGMP requirements apply to a product or facility? ..................................................... 15 E. Control of changes to a combination product ........................................................................... 18 IV. What do I need to know about the CGMP requirements specified in 21 CFR 4.4(b)? . 19 A. Provisions from the device QS regulation specified in 21 CFR 4.4(b)(1) ................................ 19 B. Provisions from the drug CGMPs specified in 21 CFR 4.4(b)(2) ............................................ 28 C. Combination products that include biological products and HCT/Ps .................................... 38 V. Application of CGMP requirements to specific types of combination products ................ 40 A. Prefilled syringe ........................................................................................................................... 41 B. Drug-coated mesh ........................................................................................................................ 46 C. Drug Eluting Stent (DES) ............................................................................................................ 49 VI. Contact Us ........................................................................................................................ 53 VII. Glossary ............................................................................................................................ 54 VIII. References .................................................................................................................... 56 Contains Nonbinding Recommendations Guidance for Industry and FDA Staff: Current Good Manufacturing Practice Requirements for Combination Products1 This guidance represents the current thinking of the Food and Drug Administration (FDA or Agency) on this topic. It does not establish any rights for any person and is not binding on FDA or the public. You can use an alternative approach if the approach satisfies the requirements of the applicable statutes and regulations. To discuss an alternative approach, contact the FDA office responsible for this guidance as listed on the title page of this guidance. I. Introduction This guidance describes and explains the final rule on current good manufacturing practice (CGMP) requirements for combination products that FDA issued on January 22, 2013 (final rule).2 (21 Code of Federal Regulations (CFR) part 4). Prior to issuance of the final rule, although CGMP regulations were in place to establish requirements for drugs, devices, biological products, and Human Cells, Tissues, and Cellular and Tissue-Based Products (HCT/Ps), there were no regulations to clarify and explain the application of these CGMP requirements to combination products. The final rule did not establish any new requirements; it was intended to clarify which CGMP requirements apply when drugs, devices, and biological products are combined to create combination products, and to set forth a transparent and streamlined regulatory framework for firms to use when demonstrating compliance with applicable CGMP requirements.3 Section II of this document provides the definition of “combination product,” an overview of the final rule, and describes the role of the lead center and other Agency components4 with respect to combination product CGMP issues. Section III addresses certain general considerations for CGMP compliance for combination products. Section IV presents the purpose and content of specific CGMP requirements addressed in the final rule. Finally, Section V analyzes hypothetical scenarios that illustrate how to comply with certain CGMP requirements 1 This guidance was prepared by the Office of Combination Products in the Office of the Commissioner in conjunction with the Center for Biologics Evaluation and Research, Center for Drug Evaluation and Research, Center for Devices and Radiological Health, and the Office of Regulatory Affairs. 2 See the Current Good Manufacturing Practice Requirements for Combination Products, 78 FR 4307 (January 22, 2013). 3 As stated in the preamble to the final rule, combination products were subject to CGMP requirements that apply to each constituent part of their combination product prior to promulgation of 21 CFR part 4. Although products developed prior to promulgation of part 4 are frequently termed “legacy” combination products, FDA deliberately does not use this terminology in this guidance because it could be inappropriately interpreted to indicate that products developed prior to promulgation of part 4 are therefore subject to fewer CGMP obligations than products developed after promulgation of part 4. 4 “Agency component” is defined at 21 CFR 3.2(b) as “the Center for Biologics Evaluation and Research, the Center for Devices and Radiological Health, the Center for Drug Evaluation and Research, or alternative organizational component of the agency.” Contains Nonbinding Recommendations for specific types of combination products. Throughout this guidance, the Agency also refers to existing guidance and additional resources that address CGMP requirements for drugs, devices, biological products, and HCT/Ps, to further inform combination product manufacturers on how to comply with CGMP requirements. FDA’s guidance documents, including this guidance, do not establish legally enforceable responsibilities. Instead, this guidance describes the Agency’s current thinking on a topic that should be viewed only as recommendations, unless specific regulatory or statutory requirements are cited. The use of the word should in Agency guidance means that something is suggested or recommended, but not required. II. Background A. Definition of a combination product As set forth in part 3 (21 CFR part 3), a combination product is a product composed of two or more different types of medical products (i.e., a combination of a drug, device, and/or biological product with one another).5 The drugs, devices, and biological products included in combination products are referred to as “constituent parts” of the combination product. Under 21 CFR 3.2(e), a combination product includes: • A product comprised of two or more regulated components, i.e., drug/device, biologic/device, drug/biologic, or drug/device/biologic, that are physically, chemically, or otherwise combined or mixed and produced as a single entity (a “single entity” combination product, such as a prefilled syringe or drug-eluting stent); • Two or more separate products packaged together in a single package or as a unit and comprised of drug and device products, device and biological products, or biological and drug products (a “co-packaged” combination product, such as a surgical or first-aid kit); • A drug, device, or biological product packaged separately that according to its investigational plan or proposed labeling is intended for use only with an approved, individually specified drug, device, or biological product where both are required to achieve the intended use, indication, or effect and where upon approval of the proposed product the labeling of the approved product would need to be changed (e.g., to reflect a change in intended use, dosage form, strength, 5 Any reference in this guidance to CGMP requirements as applicable to a combination product that includes a drug constituent part should be understood to refer as well to any combination product that includes a biological product constituent part that is also subject to regulation under the Federal Food, Drug, and Cosmetic Act (FD&C Act) as a drug, and any reference to CGMP requirements as applicable to a combination product that includes a device constituent part should be understood to refer as well to combination products that include a biological product constituent part that is also subject to regulation as a device under the FD&C Act. Contains Nonbinding Recommendations route of administration, or significant change in dose) (a “cross-labeled” combination product, as might be the case for a light-emitting device and a light- activated drug); or • Any investigational drug, device, or biological product packaged separately that according to its proposed labeling is for use only with another individually specified investigational drug, device, or biological product where both are required to achieve the intended use, indication, or effect (another type of cross- labeled combination product). B. Quality and Current Good Manufacturing Practice One of FDA’s goals is to assure the availability of quality drugs, biologics, devices, and combination products that consistently meet applicable requirements and specifications. The drug CGMP and device QS regulations, as well as the CGMPs for biologics and current good tissue practices for HCT/Ps, provide a framework of minimum requirements to help assure product quality. The core requirements embedded in these regulations provide for systems that assure proper design, monitoring, and control of manufacturing processes and facilities. This includes establishing a strong quality management system, using appropriate quality raw materials, establishing robust manufacturing and control procedures based on sound design principles, and detecting and investigating product quality deviations. In addition, these regulations call for ongoing assessment of systems and the implementation of corrective actions where appropriate. C. Overview of the final rule 1. Summary of the Final Rule The constituent parts of a combination product retain their regulatory status (as a drug or device, for example) after they are combined. The final rule clarifies that the CGMP requirements that apply to each of the constituent parts apply to the combination product they constitute. This guidance refers to a “CGMP operating system” to mean the operating system within an establishment that is designed and implemented to address and meet the current good manufacturing practice requirements applicable to the manufacture of a combination product. The final rule on CGMP requirements for combination products applies to all combination products. The CGMP requirements for constituent parts of cross-labeled combination products that are entirely manufactured at separate facilities are the same as those that would apply if these constituent parts were not part of a combination product (e.g., for a drug/device combination product, only parts 210 and 211 (21 CFR parts 210 and 211) would apply to the manufacture of the drug constituent part(s) of the cross-labeled combination product, and only part 820 (21 CFR part 820) would apply to the device constituent part(s)). With regard to cross-labeled combination products, part 4 was intended to clarify only that the CGMP obligations applicable to the drugs, devices, or biological products also apply to these types of articles when they are constituent parts of cross-labeled combination products. Contains Nonbinding Recommendations Because constituent parts of cross-labeled combination products need only comply with the requirements otherwise applicable to that type of product (e.g, part 211 for a drug constituent part or part 820 for a device constituent part), the “streamlined approach” (discussed below) is generally not relevant or applicable to them. However, to the extent that the constituent parts of a cross-labeled combination product are manufactured at the same facility, the manufacturing process would be akin to when the manufacture of the constituent parts of a co-packaged combination product occurs at the same facility. Accordingly, for cross-labeled combination products when manufactured at the same facility, the Agency does not intend to object to the use of a streamlined CGMP operating system for the manufacture of the combination product rather than distinct systems for the manufacture of each constituent part that is occurring at that facility. We believe this approach is consistent with the principles of part 4. For single-entity combination products and co-packaged combination products, part 4 identifies two ways to demonstrate compliance with CGMP requirements. Under the first option, manufacturers demonstrate compliance with all CGMP regulations applicable to each of the constituent parts included in the combination product.6 Under the second option, manufacturers implement a streamlined approach for combination products that include both a drug and a device by demonstrating compliance with either the drug CGMPs (21 CFR parts 210 and 211) or the device Quality System (QS) regulation (21 CFR part 820) and also demonstrating compliance with specified provisions from the other of these two sets of CGMP requirements.7, 8 In addition, for a combination product that includes a biological product, the manufacturer must demonstrate compliance with the CGMP requirements specific to biological products in parts 600 through 680 (21 CFR parts 600 through 680). For a combination product that includes any HCT/P, the manufacturer must demonstrate compliance with the regulations in part 1271 (21 CFR part 1271)—including the current good tissue practice (CGTP) requirements and donor eligibility requirements.9, 10, 11 Specifically, the streamlined approach under 21 CFR 4.4(b) provides that combination product manufacturers may meet the requirements of both the drug CGMPs and device QS regulation by designing and implementing a CGMP operating system that demonstrates compliance with either of the following: 6 See 21 CFR 4.4(a) 7 See 21 CFR 4.4(b). 8 While 21 CFR 211 requirements apply to all combination products because combination products always contain a drug and/or a biological product, 21 CFR 820 requirements apply only to combination products which include a device constituent part. 9 See 21 CFR 4.4(a) and (b). 10 As discussed later in section IV.C, an HCT/P may be a “constituent part” of a combination product when the HCT/P is not regulated solely under section 361 of the PHS Act because it fails to meet one or more of the criteria in 21 CFR 1271.10, and is, therefore, regulated as a drug, device, and/or biological product. See also 21 CFR 1271.20. 11 For the purposes of part 4, FDA uses the term ‘‘CGMP requirements’’ to include all such requirements found in the standards in parts 600 through 680 that may apply to biological products. We note that biological products and combination products that include biological product constituent parts must comply with all applicable requirements in parts 600 through 680. Because many of the requirements in parts 600 through 680 are not considered CGMP requirements, such requirements are not addressed in part 4 and are not a focus of this guidance. Contains Nonbinding Recommendations • The drug CGMPs and the following provisions from the device QS regulation in accordance with 21 CFR 4.4(b)(1) (drug CGMP-based streamlined approach): (i) 21 CFR 820.20 (ii) 21 CFR 820.30 (iii) 21 CFR 820.50 (iv) 21 CFR 820.100 (v) 21 CFR 820.170 (vi) 21 CFR 820.200 Management responsibility Design controls Purchasing controls Corrective and preventive action Installation Servicing OR • The device QS regulation and the following provisions from the drug CGMPs in accordance with 21 CFR 4.4(b)(2) (device QS regulation-based streamlined approach): (i) 21 CFR 211.84 (ii) 21 CFR 211.103 (iii) 21 CFR 211.132 (iv) 21 CFR 211.137 (v) 21 CFR 211.165 (vi) 21 CFR 211.166 (vii) 21 CFR 211.167 (viii) 21 CFR 211.170 Testing and approval or rejection of components, drug product containers, and closures Calculation of yield Tamper-evident packaging requirements for over-the- counter (OTC) human drug products Expiration dating Testing and release for distribution Stability testing Special testing requirements Reserve samples A manufacturer may prefer one approach over the other based, for example, on the details of the manufacturing process used at the facility or in light of other manufacturing activities undertaken at the facility. The manufacturer is not required to choose a streamlined approach based on the CGMP regulations for the constituent part that provides the primary mode of action (PMOA) of the combination product (see II.D below). For example, if the drug constituent part of a drug-device combination product provides the product’s PMOA, the manufacturer of that combination product may choose to adopt either the device QS regulation-based or drug CGMP- based streamlined approach, or choose to develop a CGMP operating system that wholly complies with the specifics of applicable provisions of both the drug CGMPs and the device QS regulation. 21 CFR 4.4(c) provides that if a facility manufactures only one type of constituent part (e.g., a drug or device constituent part) of a co-packaged or single-entity combination product, that facility is subject only to the CGMP regulations applicable to that constituent part (i.e., part 211 for a drug or part 820 for a device, as well as those under parts 600 through 680 for a biological product and part 1271 for an HCT/P). 21 CFR 4.4(d) provides that when two or more types of constituent parts to be included in a single-entity or co-packaged combination product have arrived at the same facility, or the manufacture of these constituent parts is occurring at the same facility, that facility must comply with all CGMP requirements described in part 4 Contains Nonbinding Recommendations applicable to the manufacturing activities at that facility, and a streamlined approach under 21 CFR 4.4(b) may be used to demonstrate compliance with these requirements. Similarly, if a facility manufactures a drug or device that is not a constituent part of a combination product and also manufactures a combination product, the CGMP requirements for the independently marketed drug or device do not change (compliance with parts 210/211 or part 820, respectively). Accordingly, if a facility manufactures an independently marketed device that is subject to part 820 and a combination product, it cannot manufacture the device under a drug CGMP-based streamlined operating system, even if it is used for the combination product, because this operating system only includes limited, specified provisions from the QS regulation. However, both the device and the combination product may be manufactured under a device QS regulation-based streamlined operating system, with the device that is not part of a combination product then being subject only to part 820. 2. Documentation of CGMP Approach Combination product manufacturers should be able to identify all documentation needed to demonstrate compliance with part 4, and make it readily accessible for an FDA inspection. The facility’s quality system documentation should identify the CGMP operating system for the combination product(s) manufactured at that facility, and the manufacturer should share this information with investigators at the initiation of an inspection. For combination product manufacturers implementing a streamlined approach (See Section II.B.1 above), inspection of the base CGMP operating system (i.e., 21 CFR part 210/211 or 21 CFR part 820) will typically be consistent with existing compliance programs and policies associated with it. For specified provisions from the non-base system, FDA intends to utilize the compliance program and policy elements specific to these provisions.12 Prior to the promulgation of part 4, manufacturers of combination products already had to demonstrate compliance with the applicable CGMP requirements for each constituent part of their combination product. Manufacturers should ensure that their CGMP procedures and processes are compliant with the regulatory framework provided in part 4. If the operating system requires changes to come into compliance, manufacturers should document the steps they take to ensure ongoing product safety and effectiveness. Manufacturers should be prepared to discuss their approach during inspections. Combination product manufacturers who are required to address CGMP issues as part of premarket review should identify in premarket submissions whether they are operating under a streamlined approach, and if so, whether it is a drug CGMP-based or device QS regulation-based streamlined approach.13 In premarket submissions, the CGMP approach should be identified for each relevant facility. For NDAs, BLAs and ANDAs, the CGMP approach should be described 12 For a listing of existing Compliance Program Guidance Manuals (CPGMs) for drugs, devices, and biologics, see http://www.fda.gov/ICECI/ComplianceManuals/ComplianceProgramManual/ucm2005382.htm. 13 Submission of CGMP information is not routinely required prior to clearance of 510(k)’s. As discussed, manufacturers of 510(k) combination products should identify their CGMP operating system in the quality system documentation at their facilities. Contains Nonbinding Recommendations in the Common Technical Document. For additional details on placement within the CTD, see eCTD Technical Conformance Guide, Section 3.3.2.14 For PMAs, the CGMP approach should be documented in the manufacturing section of the PMA (the manufacturing module for a modular PMA). D. The role of the lead center and other Agency components A combination product is assigned to an Agency center that will have primary jurisdiction (i.e., the lead) for that combination product’s premarket review and regulation. Under section 503(g)(1) of the Federal Food, Drug, and Cosmetic Act (FD&C Act) (21 U.S.C. 351(g)), assignment of a combination product to a lead center is based on a determination of which constituent part provides the PMOA of the combination product.15 If the PMOA of a device-biological product combination product is attributable to the biological product, for example, the center responsible for premarket review of such a biological product would have primary jurisdiction for the regulation of the combination product. The lead center for premarket review of the combination product also has the lead for ensuring compliance with CGMP regulatory requirements. Regardless of the PMOA, Agency components will coordinate as appropriate to enable efficient, effective CGMP regulatory oversight, including appropriate CGMP inspections. The lead center is a manufacturer’s primary point of contact. Manufacturers may also contact the Office of Combination Products (OCP) for assistance, as needed, in identifying appropriate contact points (including those in the lead center), resolving substantive issues, or otherwise facilitating interactions with the Agency and collaboration among Agency components, including centers and the Office of Regulatory Affairs (ORA). III. General Considerations for CGMP Compliance This section addresses some general considerations for CGMP compliance for combination products. Note that this guidance addresses only CGMP requirements. Additional requirements may apply including the need for premarket submissions as a result of changes to product design, intended use, or manufacture. 14 Available at http://www.fda.gov/downloads/Drugs/DevelopmentApprovalProcess/FormsSubmissionRequirements/ElectronicSub missions/UCM465411.pdf. 15 The “primary mode of action” of a combination product is the single mode of action (drug, device, or biological product) that provides the most important therapeutic action of the combination product. The most important therapeutic action is the mode of action expected to make the greatest contribution to the overall intended therapeutic effects of the combination product. See 21 CFR 3.2(k) (which defines “mode of action” and “therapeutic”) and (m) (which defines primary mode of action). For more information on product classification, assignment, and PMOA, see the guidance for industry How to Write a Request for Designation (RFD)(April 2011). Contains Nonbinding Recommendations A. Demonstrating compliance The final rule identifies two ways for co-packaged and single-entity combination product manufacturers to demonstrate compliance with applicable CGMP requirements. The Agency intends for the term “demonstrate” to apply for part 4 as it would be for purposes of fulfilling the underlying CGMP regulations listed in 21 CFR 4.3. Manufacturers must demonstrate compliance with each applicable CGMP requirement for constituent parts and combination products.16 If a streamlined approach is used, the manufacturer must demonstrate compliance with all of the relevant provisions of either the drug CGMPs or device QS regulation, and the provisions specified in 21 CFR 4.4(b) for the other set(s) of CGMP requirements applicable to the product. Further guidance on how to demonstrate compliance with the regulations specified in 21 CFR 4.4(b) is provided in section IV of this guidance. A manufacturer who implements a streamlined approach is not expected to demonstrate compliance with the specific provisions of the non-base set of requirements other than those specified in 21 CFR 4.4(b) (e.g., for a drug CGMP-based streamlined approach, the manufacturer must demonstrate compliance with applicable drug CGMPs plus the six specified provisions from part 820, as applicable, but the manufacturer does not need to demonstrate compliance with the other specific provisions in part 820). As provided in 21 CFR 4.4(e), in the event of a conflict between regulations applicable under part 4, the regulations most specifically applicable to the constituent part in question supersede the more general. The intent of this provision is to address any potential conflicts between regulations. This provision does not provide a basis for the Agency to require manufacturers to demonstrate compliance with provisions not otherwise identified in part 4 as applicable to them. Some of the provisions specified in part 4 from the drug CGMPs and device QS regulation cross-reference other provisions of parts 211 and 820, respectively. This raises the question of whether manufacturers must specifically demonstrate compliance with these cross- referenced provisions. FDA believes that manufacturers can adequately address the expectations of these cross-referenced provisions through implementation of either a drug CGMP-based or device QS regulation-based CGMP streamlined approach. For example, 21 CFR 211.170 (Reserve samples) references 21 CFR 211.192 (Production record review). However, 21 CFR 211.192 is not a specified provision in 21 CFR 4.4(b)(2) because part 820 encompasses the requirements of that section. In particular, under the CAPA requirements in 21 CFR 820.100, a manufacturer operating under a device QS-based streamlined approach should have the systems in place that would satisfy the requirements of 21 CFR 211.192. Similarly, 21 CFR 211.103 (Calculation of yield) references 21 CFR 211.68 (Automatic, mechanical, and electronic equipment) in relation to using automated equipment for yield calculations and maintaining appropriate controls over such equipment. Corresponding provisions in 21 CFR 820.70(i), applicable under a QS-regulation based streamlined approach, 16 21 CFR part 4. Contains Nonbinding Recommendations require that automated data processing systems be validated for their intended uses. To take another example, the definition of design output in 21 CFR 820.3 makes reference to “device master record.” Both part 211 and part 820 have requirements for “master records” (21 CFR 211.186, Master Production and Control Records and 21 CFR 820.181, Device Master Record). FDA believes the substantive expectations of these master record provisions are aligned and needed to control product development and manufacture. This guidance does not focus on how to demonstrate compliance with provisions of the drug CGMPs and device QS regulation other than those specified in 21 CFR 4.4(b). Other provisions of these regulations address a variety of manufacturing considerations regarding, for example, in-process materials, facility and equipment, record-keeping, labeling, personnel, inputs, testing, and distribution. B. Investigational products Part 4 does not alter the scope of the underlying CGMP regulations for drugs, devices, biological products, and HCT/Ps. In particular, part 4 does not alter the applicability of these CGMP regulations to investigational products. An investigational drug for use in a phase 1 study is subject to the statutory requirements set forth in 21 U.S.C. 351(a)(2)(B). The production of such a drug is generally exempt from compliance with the regulations in parts 210 and 21117 and, therefore, so is an investigational combination product that includes a drug constituent part for use in a phase 1 study. This exemption does not apply to an investigational combination product or drug constituent part, however, once it has been made available for use by or for the sponsor in phase 2 or phase 3 studies, nor does the exemption apply to a drug product that has been lawfully marketed. For additional information on study phases, see 21 CFR 312.21. Under 21 CFR 812.1, investigational devices are exempt from part 820 except for design control requirements under 21 CFR 820.30. This exemption also applies to the manufacturing of investigational combination products that include device constituent parts. Investigational combination products that include a device constituent part are subject to design controls (except when the device constituent part is exempt from design controls, see III.C.3 below), but not to the other provisions of part 820. Design controls should start as early as possible, once a company has determined that a product appears to have clinical utility and management has committed to further development (see also IV.A.2 below).18 The Agency considers these exemptions from requirements under parts 211 and 820 applicable to combination products and constituent parts of combination products whether they 17 See 21 CFR 210.2(c). 18 The preamble to the device QS regulation (61 FR 52602) provides additional detail on when design controls apply for products early in the design life-cycle: “The design control requirements are not intended to apply to the development of concepts and feasibility studies. However, once it is decided that a design will be developed, a plan must be established to determine the adequacy of the design requirements and to ensure that the design that will eventually be released to production meets the approved requirements.” (61 FR 52616, Comment 62) Contains Nonbinding Recommendations are being studied under an investigational device exemption (IDE) or an investigational new drug application (IND). Even when these exemptions apply, however, methods, facilities, and manufacturing controls that are appropriate for the investigational products should be used. When developing and applying appropriate manufacturing practices, the Agency recommends that the hazards and associated risks from the manufacturing environment that might adversely affect an investigational combination product be considered. For further information on the CGMP requirements for investigational products, see 21 CFR 210.2(c), 21 CFR 820.1, 61 Federal Register (FR) 52,616-52,617, and the Guidance for Industry on CGMP for Phase 1 Investigational Drugs (July 2008). Manufacturers who have questions about IDE or IND requirements for their combination product should contact the lead center or OCP, if needed, for assistance. C. Definitions and terminology Unless 21 CFR part 4 expressly states otherwise, terms used have the same meaning as when used in the underlying, referenced regulations. This section addresses the meaning and significance for combination products of the terms “manufacture” and “manufacturer,” “constituent part” and “component,” “device,” and drug “container” and “closure.” It also addresses the meaning of “convenience kit” as a type of co-packaged combination product. Other relevant definitions can be found in part 4 and the underlying CGMP regulations (see, e.g., 21 CFR 210.3, 21 CFR 211.3, 21 CFR 600.3, 21 CFR 606.3, 21 CFR 820.3, and 21 CFR 1271.3) 1. “Manufacture” and “manufacturer” The definition of the term “manufacture” in part 4 is intended to include all of the activities considered within the scope of manufacturing for drugs, devices, biological products, and HCT/Ps. Accordingly, the definition of “manufacture” in 21 CFR 4.2 includes, but is not limited to, designing, fabricating, assembling, filling, processing, testing, labeling, packaging, repackaging, holding, and storage. For example, if a company designs a drug-device combination product, that activity constitutes manufacture of that product, and the facility at which the design work occurs is a manufacturing facility. That company is a manufacturer subject to part 4 for the design activities it performs, even if all other aspects of the combination product’s manufacture (e.g., fabricating, labeling, or packaging) are performed by another entity. Similarly, a facility responsible for the holding and storage of a combination product would be subject to related CGMP requirements such as 21 CFR 211.142 (Warehousing procedures) and/or 21 CFR 820.150 (Storage), depending upon whether the facility applies a streamlined approach and if so, which approach it applies. 2. “Constituent part” versus “component” The term “constituent part” is used by the Agency as a succinct way to identify a drug, device, or biological product included in a combination product. Under the drug CGMPs, “component” is defined as “any ingredient intended for use in the manufacture of a drug product, Contains Nonbinding Recommendations including those that may not appear in such drug product.”19 Under the device QS regulation, the term “component” is defined as “any raw material, substance, piece, part, software, firmware, labeling, or assembly which is intended to be included as part of the finished, packaged, and labeled device.”20 Components can include sub-assemblies that are further processed to make a finished device. In contrast, a finished device is “suitable for use or capable of functioning, whether or not it is packaged, labeled, or sterilized,”21 as would be the case for a device constituent part as incorporated into a combination product.22 A facility that manufactures only device components, including device components used in a combination product, is not made subject to the device QS regulation by part 4.23 Similarly, a facility that manufactures solely active pharmaceutical ingredients (APIs) is not subject to part 211, though it is subject to statutory CGMP requirements under Section 501 of the FD&C Act (21 U.S.C. 351). Part 4 does not make such a drug component manufacturing facility subject to part 211 if those components are for use in a combination product. However, a facility that manufacturers a drug-device combination product formed from components is subject to parts 211 and 820, and must comply with these two sets of regulations as provided in part 4.24 In short, the terms “constituent part” in part 4 and “component” in the CGMP regulations serve different regulatory purposes. The use of the term “constituent part” in part 4 refers to drugs, devices, and biological products included in combination products and does not alter the meaning of the term “component” or alter whether the regulations listed in 21 CFR 4.3 apply to component manufacturers. 3. Drug containers and closures versus delivery devices The Agency draws a distinction between mere drug containers and closures and containers and closures that are also devices. The essential difference is generally whether the article is designed to deliver the drug it contains or merely to hold it. If the article merely holds the drug, it is only subject to drug CGMPs as a container or closure. An article that holds or contains a drug, but also delivers it, may also be a device subject to the device QS regulation in addition to the requirements relating to drug containers and closures. A container closure system is the sum of packaging components that together contain and protect the drug product. This includes primary and secondary packaging components if the latter are intended to provide additional protection to the drug product.25 Elements of container closure systems that are device constituent parts include piston syringes, metered dose inhalers (MDIs), and containers for intravenously-administered (IV) fluids (such as IV bags containing 19 21 CFR 210.3. 20 21 CFR 820.3(c). 21 21 CFR 820.3(l). 22 21 CFR 4.2. 23 See 21 CFR 820.1(a). 24 See 78 FR 4313-4314, Comment 15. 25 See the Guidance for Industry on Container Closure Systems for Packaging Human Drugs and Biologics: Chemistry, Manufacturing, and Controls Documentation (May 1999). Contains Nonbinding Recommendations saline or anti-coagulants), which both hold and deliver the drugs or biological products they contain.26 In the case of an IV container, the drug is delivered to the patient via the IV line. The Agency has exempted some devices from all or certain provisions of the device QS regulations. For example, 21 CFR 880.6430 exempts liquid medication dispensers (cups, droppers, etc.) from all provisions of the device QS regulation with the exception of 820.180 and 820.198. Such exemptions may extend to device constituent parts of combination products and to the combination products of which they are a part. If the exemptions for a device constituent part of a drug-device combination product cover all of the part 820 provisions included in 21 CFR 4.4(b)(1), then the Agency will consider the combination product manufacturer CGMP compliant so long as the CGMP operating system is compliant with part 211 (no demonstration of compliance with part 820 will be necessary). However, if a device that would ordinarily be exempt from all or certain provisions in part 820 is incorporated into a container closure system, for example if a dropper is incorporated into the cap of a bottle of a drug, this may be a new use of the device such that the exemptions from part 820 may not be applicable.27 In any event, when incorporated into a container closure system, the device must be addressed as part of the container closure system for purposes of part 211 (e.g., requirements under 21 CFR 211.84, 211.165, and 211.166, discussed in section IV.B). Manufacturers should document their evaluation if they believe a container closure system that has delivery attributes is not a device, or if they believe a device constituent part is exempt from any or all provisions under the device QS regulation. Manufacturers who have questions about whether their container closure system, or an element thereof, is regulated as a device, or whether exemptions from part 820 apply, are encouraged to discuss the issue with the lead center or OCP, as needed. 4. Convenience kits A kit that includes two or more different types of medical products (e.g., a device and a drug) is a co-packaged combination product and, therefore, part 4 applies to the manufacture of the kit. The CGMP requirements applicable to a kit manufacturer depend on what products are included in the kit. If the kit includes only products that are 1) legally marketed independently and 2) packaged in the kit as they are when independently marketed (including any labeling used for 26 The Agency notes that other Agency guidance addresses syringes and other devices that contain a drug as “container closures” for the drug, and focuses on considerations related to their use as container closures, while addressing only in a summary manner other requirements applicable because these container closures are also regulated as devices. See, e.g., Guidance for Industry Container Closure Systems for Packaging Human Drugs and Biologics[1999]. As reflected in this section and elsewhere in this guidance, such devices are subject to container closure requirements because they hold a drug. However, because they are also devices, they and the combination product of which they are a part are subject to additional requirements, including under part 820. 27 Although outside the scope of this guidance, we note that changes to the intended use of constituent parts of a combination product may require premarket review by FDA. Contains Nonbinding Recommendations independent marketing), it is a “convenience kit,”28 and the only manufacturing steps for the combination product would be the assembly, packaging, labeling, any sterilization, and further processing of the kit itself. Accordingly, the kit manufacturer would only have to demonstrate compliance with CGMP requirements with respect to those manufacturing activities. Kit manufacturers should carefully analyze what CGMP requirements apply to a kit. 27 If a kit includes any products that are repackaged, relabeled, or otherwise modified from the independently marketed product, then the kit is not a convenience kit. Likewise, if the kit manufacturer includes labeling for the kit that modifies the intended use for a constituent part, then the kit is not a convenience kit. In these cases, the manufacturer would have to demonstrate compliance with CGMP requirements for the constituent parts and the overall product. Also, if a device constituent part would be considered exempt from the device QS regulation if marketed outside the kit, the kit manufacturer may not be able to claim this exemption from part 820 if the intended use of the device constituent part in the kit is new. Co-packaged combination product manufacturers, including manufacturers of convenience kits, should carefully consider the impact of any sterilization process on the items in the co-package.29 For example, a constituent part may be sensitive to further processing, as may be the case for surgical sutures. Similarly, some sterilization methods suitable for devices, such as irradiation, are not suitable for many drugs. Also, additional verification to confirm no degradation in safety and effectiveness after any re-sterilization may be necessary. For example, manufacturers should consider whether re-sterilization affects stability, material properties, and expiration dating/shelf-life of any of the products within the kit. Additional issues may need to be considered, including validation of the sterilization process to ensure sterility for each constituent part within the kit, as appropriate.30 Manufacturers should document their evaluation if they believe a kit qualifies as a convenience kit or that a device constituent part (and, therefore, a kit) should not be subject to requirements under part 820. Kit manufacturers who have questions about whether their kit is a convenience kit, or about the applicability of part 820 requirements, are encouraged to contact the lead center or OCP, as needed. D. What CGMP requirements apply to a product or facility? While combination product manufacturers must demonstrate compliance with all of the CGMP regulations applicable to their combination product under 21 CFR 4.3, they may, as discussed above, demonstrate compliance with the drug CGMPs and device QS regulation requirements through one of the streamlined approaches under 21 CFR 4.4(b). Further, not all 28 The term “convenience kit” as used in this guidance embraces solely the definition presented in this section, initially provided in the preamble to the part 4 regulation (see 78 FR 4310). The term “convenience kit” is used in other FDA regulations for different purposes. See, for example, 21 CFR 801.3. 29 See, e.g., 21 CFR 211.166. 30 See, for example, the Guidance for Industry on Sterilized Convenience Kits for Clinical and Surgical Use (January 2002). Contains Nonbinding Recommendations the provisions of the CGMP regulations listed in 21 CFR 4.3 may be applicable to a specific combination product or constituent part. 1. Applicability of CGMP requirements to a product The preamble to the proposed rule addressed which CGMP requirements apply to which combination products (see 74 FR at 48426), noting, for example, that only an over-the-counter (OTC) combination product must comply with the tamper-evident packaging requirements in the drug CGMPs and only combination products that include a type of device constituent part that is installed or serviced must comply with installation and servicing requirements in the device QS regulation. The preamble to the final rule addressed similar considerations for combination products that include a biological product constituent part, explaining that many of the requirements for biological products are applicable only to certain types of biological products. For example, blood and blood components are subject to the CGMP requirements for such products under part 606 (21 CFR part 606). In addition, a vaccine manufactured using a spore- forming microorganism would be subject to 21 CFR 600.11(e)(3). Similarly, not all CGMP requirements may apply at a facility that performs only certain aspects of the manufacture of a combination product. As 21 CFR 210.2(b) and 820.1(a)(1) describe, an entity that engages in only some operations subject to the regulations in parts 210, 211, 600 through 680, 820, and 1271, need only comply with the regulations applicable to those operations. For example, a facility that manufactures a co-packaged combination product that includes a finished, already-packaged drug manufactured under the drug CGMPs and received from another facility need not calculate yield for that drug constituent part. 2. What is the meaning of “where appropriate” in the CGMP, QS, and CGTP regulations? Firms must demonstrate compliance with all regulations applicable to their product and facility under part 4. However, the drug CGMPs, device QS regulation, and CGTPs for HCT/Ps use language such as “where appropriate” or “as necessary” to acknowledge that certain measures may not be necessary or applicable under certain circumstances and that manufacturers must pursue such measures if they are needed. Such language indicates that firms have the opportunity to document justifications for determining that such a measure or approach is not appropriate or necessary for a particular product or the specific manufacturing activity they are undertaking.31 Such justifications should generally be maintained within the quality system documentation and may warrant Agency review prior to implementation depending on the product type and relevant premarket submission obligations. 31 Under both 21 CFR 820.1(a)(3) and 1271.150(e), a requirement that is qualified by “where appropriate,” is “appropriate” if, for example, non-implementation of the requirement could reasonably be expected to result in the product not meeting its specified requirements. In the case of an HCT/P, these may be requirements related to preventing introduction, transmission, or spread of communicable diseases, or a manufacturer’s inability to carry out any necessary corrective action. Under both provisions, a requirement is deemed to be appropriate unless the manufacturer can document justification that it is not. Contains Nonbinding Recommendations For example, 21 CFR 820.30(i) stipulates that each manufacturer establish32 and maintain procedures for “the identification, documentation, validation or where appropriate verification, review, and approval of design changes before their implementation” (emphasis added). Changes to the design, such as changes to properties of the material or dimensional specifications, may not need to be validated if they can be verified through appropriate measurement and test methods. However, changes that could impact user needs, such as changes to the user interface, may require validation. Similarly, part 211 requires compliance with certain duties “as appropriate” (e.g., 21 CFR 211.84(a) addressing the sampling, testing, or examining of components, containers, and closures prior to release by the quality control unit). Containers may not need to be tested, for example, if visual examination is sufficient to evaluate critical attributes. 3. What CGMP responsibilities apply to specific manufacturers and facilities, and how should CGMP compliance be coordinated across facilities? A facility that manufacturers a constituent part of a combination product or a complete combination product must be compliant with the CGMP requirements applicable to each manufacturing process that occurs at that specific facility. In addition, the combination product owner (the holder of the marketing authorization for the product) retains overall responsibility for the product, even if the owner is not directly engaged in its manufacture. As outlined below, quality agreements and audits can be helpful in assuring compliance with applicable CGMP requirements. A facility that manufactures only a finished device intended to be a constituent part of a combination product (i.e., does not engage in any other manufacturing of the combination product) must comply only with the device QS regulation. Similarly, a facility that manufactures only a drug intended to be a constituent part of a combination product (i.e., does not engage in any other manufacturing of the combination product), must comply only with the drug CGMPs. Even if a facility is manufacturing only one type of constituent part for a combination product, the CGMP operating system should take into account considerations for the combination product as a whole as appropriate. Before changes are made to the manufacturing process of a constituent part, the CGMP operating system should ensure consideration of whether such changes could affect performance and/or interaction with the other constituent part(s) and, if so, whether the safety and effectiveness of the combination product could be impacted. Quality agreements with constituent part manufacturer(s) are one way to ensure that changes to a constituent part are transparent to a combination product manufacturer or owner. Some CGMP requirements concern the product as a whole, such as design controls, and some concern overarching considerations for the manufacturing process as a whole, such as CAPA requirements. Take, for example, a manufacturing facility collecting nonconformance data that are trended as an input to the CAPA system for a combination product. If a problem is detected that requires a product or process design change, the change may require modification of manufacturing activities at another facility or the expertise to develop and implement the change may reside at a different facility. Similarly, a facility that only handles customer calls 32 21 CFR 820.3(k) states that “Establish means define, document (in writing or electronically), and implement.” Contains Nonbinding Recommendations may provide relevant complaint data to another facility responsible for trending all quality data and managing the CAPA system. A CAPA system that is shared between facilities, or facility- specific CAPA systems with established links between them, may facilitate handling of issues requiring multi-facility collaboration. Regardless of the approach, the CAPA system(s) should allow for adequate flow of information between facilities and manufacturers for the combination product and appropriate investigation and resolution of identified CAPA issues. Manufacturing activities that occur at multiple facilities and associated CGMP operating systems should be coordinated appropriately. Each manufacturing facility for a combination product should have documentation specifying its respective responsibilities, and the manufacturer of the finished combination product should have access to this documentation. For example, if the manufacturer of the finished combination product uses a specification developer to design the finished product, that manufacturer should have the design control records or have access to them if they are held by the specification developer. In addition, the manufacturer should have assurances that the specification developer maintained an adequate design control system. To give another example, if product testing occurs at a contract testing facility, the manufacturer of the finished combination product should have documentation of the testing conducted and controls applied at the contract facility or have access to the documentation if held at the contract facility. Accordingly, manufacturers should address access to such records among other issues as part of supplier evaluation and oversight. Measures that might be taken to ensure CGMP compliance at all manufacturing facilities for the combination product include auditing and other oversight activities. For example, when multiple facilities participate in the manufacturing process, the owner may facilitate CGMP compliance by coordinating interactions among the facilities, including by entering into comprehensive quality agreements with the various facilities and suppliers . These quality agreements may, for instance, specify expectations as to which facility will perform what activities and develop and maintain what documentation needed to demonstrate compliance with particular CGMP requirements (based, for example, on which aspects of manufacture each facility conducts). These agreements may also detail what measures a facility will take to ensure compliance with CGMP requirements and any other relevant duties established by the owner for that facility. For example, an owner may contract for the manufacture of the final combination product with a contract manufacturing facility, and detail in the supplier agreements the CGMP responsibilities and approaches for that facility. E. Control of changes to a combination product While not an issue unique to combination products, coordination of changes among manufacturers participating in the manufacture of a combination product is an important CGMP issue. Appropriate consideration should be given to any implications for the safety or effectiveness of the combination product that might arise from changes to the combination product or its constituent parts. Single-entity and co-packaged combination product manufacturers must establish arrangements with their suppliers, contractors, and consultants to receive notice of changes in the product or service, where possible, in accordance with 21 CFR 820.50. This notice should Contains Nonbinding Recommendations address changes the supplier makes to its process or product—including to an API, other drug components, or a container-closure system—that it manufactures, if the change might affect the downstream manufacturing process or the quality of the combination product itself. These combination product manufacturers should also establish procedures for acceptance of components, containers/closures, and constituent parts to ensure both detection and evaluation of any changes that are critical to the safety or effectiveness of the combination product prior to incorporating them into the finished combination product.33 Similarly, if one entity manufactures one constituent part of a cross-labeled combination product and another entity manufactures the other constituent part, both should have procedures in place to inform one another of changes that may affect the safety or effectiveness of the combination product, and to confirm that the specifications for the respective constituent parts remain appropriate or are updated as needed to ensure that the combination product remains safe and effective. For example, a change to the drug constituent part of a cross-labeled combination product might require a design change to the device constituent part for the combination product to remain safe and effective. Accordingly, awareness and assessment of drug changes to determine whether they require a change to the device constituent part(s) of such a combination product may be important to compliance with design control requirements for the device under 21 CFR 820.30. Similarly, a change to a device constituent part of a cross-labeled combination product may necessitate a change to a drug constituent part, which may require a change in its chemistry, manufacturing, and controls (CMC).34, 35 IV. What do I need to know about the CGMP requirements specified in 21 CFR 4.4(b)? A. Provisions from the device QS regulation specified in 21 CFR 4.4(b)(1) This section provides summary descriptions of the provisions from the device QS regulation with which manufacturers of single-entity and co-packaged combination products that include a device constituent part must demonstrate compliance when using the drug CGMP- based streamlined approach established under 21 CFR 4.4(b)(1), including considerations specific to applying these device QS regulation requirements to combination products. This discussion is not meant to provide a comprehensive analysis, but rather to help manufacturers— particularly drug and biological product manufacturers who may be less familiar with the device QS regulation—understand the purpose and basic elements of the device QS regulation 33 21 CFR 211.84 details how a manufacturer must sample, test, examine, and accept or reject drug product components, containers, and closures. 34 For additional information on guidance related to CMC topics, see FDA’s webpage: http://www.fda.gov/Drugs/GuidanceComplianceRegulatoryInformation/Guidances/ucm064979.htm. 35 While beyond the scope of this guidance, it bears noting that product owners may be obligated to notify the Agency of changes or seek Agency approval prior to making them, depending upon the nature of the change. See, for example, 21 CFR 314.70, 601.12, 807.81(a)(3) and 814.39. Accordingly, controlling changes to combination products and the processes and facilities used for their manufacture can be important to ensure compliance with other regulatory requirements (in addition to CGMP requirements). Contains Nonbinding Recommendations provisions specified in 21 CFR 4.4(b)(1). This section also includes references to additional guidance documents that may be helpful.36 Section V presents hypothetical examples offering additional guidance on how to address these provisions for a combination product. 1. Management responsibility (21 CFR 820.20) Requirements under 21 CFR 820.20 ensure that management with executive responsibility (i.e., senior employees of a manufacturer who have the authority to establish or make changes to the quality policy and quality system)37 are actively engaged in oversight of the quality system, and reflect the expectation that management with executive responsibility demonstrate an active, ongoing commitment to quality system development and implementation.38 Statutory CGMP provisions and regulations for drugs establish requirements related to management responsibility, and the Agency has also issued guidance on this topic.39 However, there are specific requirements in 21 CFR 820.20 that are not explicitly addressed in drug CGMP requirements, and a manufacturer of a combination product that includes a device constituent part must ensure that the elements required under 21 CFR 820.20 are satisfied. A combination product manufacturer must establish and maintain an adequate organizational structure to ensure that the product is designed and produced in accordance with CGMP requirements. This structure must: establish the appropriate responsibility, authority, and interrelation of all personnel who manage, perform, and assess work affecting quality; provide adequate resources for management, performance of work, and assessment activities; and include 36 This section does not address 21 CFR 4.4(b)(1)(v) and (vi), which require manufacturers to demonstrate compliance with installation and servicing requirements under 21 CFR 820.170 and 820.200, respectively. These requirements are included in 21 CFR 4.4(b)(1) to ensure manufacturers comply with them when applicable to a single-entity or co-packaged combination product. However, the Agency anticipates that installed and serviced devices will rarely be constituent parts of such combination products. If they are constituent parts of a combination product, they are more likely to be separately manufactured and marketed as constituent parts of cross-labeled combination products. In such cases, as discussed in Section II.C.1 II.B, each constituent part manufacturer would be subject to the CGMP requirements associated with the constituent part it manufactures. Accordingly, the device constituent part of such a cross-labeled combination product would be subject to installation and servicing requirements. 37 21 CFR 820.3(n). As stated in the preamble to the device QS regulation, “Management with executive responsibility is that level of management that has the authority to establish and make changes to the company quality policy. The establishment of quality objectives, the translation of such objectives into actual methods and procedures, and the implementation of the quality system may be delegated. The regulation does not prohibit the delegation. However, it is the responsibility of the highest level of management to establish the quality policy and to ensure that it is followed … It is without question management’s responsibility to undertake appropriate actions to ensure that employees understand management’s policies and objectives. Understanding is a learning process achieved through training and reinforcement. Management reinforces understanding of policies and objectives by demonstrating a commitment to the quality system visibly and actively on a continuous basis. Such commitment can be demonstrated by providing adequate resources and training to support quality system development and implementation.” (61 FR 52602-52612) 39 See Section 501 of the FD&C Act [21 USC 351], which requires oversight and controls to ensure product quality, including to manage risks and establish the safety of raw materials, in-process materials, and the finished drug product (establishing that “current good manufacturing practice” includes management oversight of manufacturing and controls to ensure quality and lifecycle risk management). See also 21 CFR 211.22, 211.25, and 211.180; and the Guidance for Industry Q10 Pharmaceutical Quality System (April 2009). Contains Nonbinding Recommendations an appointed management member who is responsible for ensuring that quality system requirements are effectively established and maintained, and for reporting on the performance of the quality system to management with executive responsibility.40 Management with executive responsibility must establish the policy and objectives for and commitment to quality.41 These policies and objectives are reflected in the quality plan and quality system procedures.42 The quality plan must define the quality practices, resources, and activities relevant to the combination product that is being designed and manufactured and must establish how the quality requirements will be met.43 The plan can either be an independent document, or it can reference elements of the manufacturer’s quality system. The quality system procedures (21 CFR 820.20(e)) ensure compliance with each aspect of the CGMPs applicable to the combination product.44 The number, complexity, and structure of a combination product manufacturer’s procedures and instructions may vary depending on factors such as the manufacturer’s organizational structure and the complexity of the combination product being manufactured. Drug manufacturers may already have some such procedures in place as part of the requirements for a quality control unit under 21 CFR 211.22 and can reference these procedures and augment them as needed to meet the requirements of 21 CFR 820.20. Management with executive responsibility must periodically review the suitability and effectiveness of the quality system, including to ensure that the quality system satisfies the established quality policy and objectives.45 These reviews must be conducted at defined intervals and with sufficient frequency. Management review procedures should ensure that management has adequate access to relevant information from facilities contracted to perform manufacturing activities for the combination product. 2. Design controls (21 CFR 820.30) The preamble to the rule discusses design control requirements for combination products at some length.46 This section discusses the design controls that apply to single-entity or co- packaged combination products that include a device constituent part that is subject to them.47 Design control activities confirm that there are no negative interactions between constituent parts, and ensure that their combined use results in a combination product that is safe and effective and performs as expected. 40 21 CFR 820.20(b). 41 21 CFR 820.20(a). 42 See 21 CFR 820.20(d) and (e). 43 21 CFR 820.20(d). 44 21 CFR 820.20(e) 45 21 CFR 820.20(c). 46 See 78 FR 4314-4315. 47 If a manufacturer claims that the device constituent part or combination product is exempt from 21 CFR 820.30, the manufacturer should document its evaluation to support this determination. See sections III.C.3 and C.4 of this guidance; see also 21 CFR 820.30(a)(1). Contains Nonbinding Recommendations The following is a description of design control requirements and the documentation that must be maintained for co-packaged and single-entity combination products.48 While pharmaceutical development focuses on drug considerations, if broadened to take into account the other constituent parts of combination products and how they interrelate, many pharmaceutical development practices (for example, Quality by Design principles49) can be leveraged and built upon when demonstrating compliance with design controls for a combination product. The Agency recognizes that the terminology used in 21 CFR 820.30 can differ from that used for pharmaceutical development. Manufacturers should be able to communicate to the Agency how the terminology they use relates to design control principles and requirements. Design control requirements apply to activities during product development as well as to postmarket changes to the design or manufacturing process. Accordingly, the activities described below may be conducted as part of premarket development and reflected in documentation submitted as part of the marketing authorization process. Regardless of when the activity occurs or where related records may reside, the CGMP operating system should include or reference appropriate documentation to ensure readily available access to this documentation for FDA inspection.50 The extent and complexity of the design controls process and associated documentation will vary based on the product. For example, consider a drug product that is already legally marketed independently that will have the same formulation, route of administration and intended use when marketed as part of a combination product that also incorporates a delivery device. Design controls would begin when the delivery device configuration is judged to be feasible and appropriate to develop. The drug properties would be inputs for design control activities that would focus on ensuring that the device appropriately delivers the drug and that the drug quality is not adversely affected by its contact with the device. Conversely, for a novel combination product with novel drug and device constituent parts, design controls ensure coordinated development of the drug and device resulting in a final combination product that meets user needs and achieves intended uses. The extensiveness of design control activities and related documentation for products should also be commensurate with the phase of product development. As part of the design controls, a design and development plan must be established to describe or reference the design and development activities and define responsibility for implementation. The plans must identify and describe the interfaces with different groups or activities that provide, or result in, input to the design and development process.51 48 While outside the scope of 21 CFR 4.4(b)(1), it bears noting that the design control process and design history file for the device constituent parts of cross-labeled combination products should address the suitability of the device for use as part of the combination product, including the interactions and interrelationships between it and other constituent parts of the combination product. 49 See the Guidance for Industry on Q8(R2) Pharmaceutical Development (November 2009), http://www.fda.gov/downloads/Drugs/.../Guidances/ucm073507.pdf. 50 See 21 CFR 820.30(j), 820.180, and 211.180. 51 21 CFR 820.30(b). Contains Nonbinding Recommendations Design input requirements for the combination product should include considerations such as performance characteristics, safety and reliability requirements, and expected needs of product users and patients.52 Design inputs should be considered early in product development to ensure that development efforts are consistent with the product’s intended use, including the needs of users, including patients. Once the design inputs have been established, the design outputs (e.g., specifications and engineering drawings) must be developed based on those inputs.53 Once design outputs have been established for all design inputs, design verification and validation activities must be performed to ensure that the combination product design output meets design input requirements, including user needs and intended uses. Design review is also required to ensure that formal and documented reviews of the design are planned and conducted at appropriate stages of the product’s design development,54 and all of these activities must be documented in the design history file.55 Design inputs ensure that design requirements are appropriate to address the intended use of the product, and design outputs include documentation of the product specifications that can be evaluated against the design inputs as development progresses. Similarly, Quality Target Product Profile (QTPP) in pharmaceutical development involves prospective consideration of the quality characteristics of a drug product to ensure desired quality taking into account safety and efficacy of the drug product. A manufacturer may identify potential Critical Quality Attributes (CQAs) or properties of a drug product that should be within appropriate limits, ranges, or distributions to ensure product quality and refine these CQAs as product development continues. QTPP and CQA principles may be applied for combination products in a manner consistent with design input and output requirements. In addition, when developing a combination product, the QTPP and CQA for the drug constituent part may be helpful in establishing design inputs and design outputs for the combination product. Verification means confirmation by examination and provision of objective evidence that specified requirements have been fulfilled.56 Design verification confirms that the product developed is consistent with the assumptions made by the design team when developing design inputs, but does not necessarily confirm that the product is safe and effective for its intended use. Design verification activities may include, for example, performance tests, safety tests, or visual inspections. Design validation means establishing by objective evidence that product specifications conform to user needs and intended use(s).57 Design validation ensures that the product is designed correctly to achieve its intended purpose(s), and includes testing of production units or their equivalents (with appropriate justification58) under actual or simulated use conditions. 52 See 21 CFR 820.30(c). 53 See 21 CFR 820.30(d). 54 See 21 CFR 820.30(e). 55 See 21 CFR 820.30(j). 56 See 21 CFR 820.30(f) and 21 CFR 820.3(aa). 57 See 21 CFR 820.30(g) and 21 CFR 820.3(z)(2). 58 The preamble to the device QS regulation (61 FR 52619) provides additional detail on use of equivalents: “When equivalent devices are used in the final design validation, the manufacturer must document in detail how the device was manufactured and how the manufacturing is similar to and possibly different from initial production. Where Contains Nonbinding Recommendations Design validation activities, for example, may include simulated use testing or clinical/nonclinical evaluation, including human factors59 and software validation. Some design verification (e.g., bench and/or pre-clinical testing) and validation (e.g., human factors testing, when appropriate) will typically be completed prior to the initiation of clinical studies of safety and efficacy for the combination product, which are also part of design validation. Clinical studies conducted to support safety and/or efficacy of the constituent parts of a combination product may be appropriate to be leveraged as part of the cumulative design validation efforts for the overall combination product. In addition, manufacturers must perform risk analysis where appropriate,60 which should begin early in the design process and continue throughout the lifecycle for the product. Risk analysis should enable identification of unacceptable risks so that they can be mitigated. It influences other aspects of design control and additional activities including purchasing controls (see section IV.A.3). Although existing risk analysis for products used as constituent parts of the combination products may be relevant, risk analysis should include considerations for the combination product as a whole to identify risks associated with its design, manufacturing processes, and intended uses. Some risks may be identifiable during initial design development and addressed in design inputs, while others may become apparent later in product development, during premarket review, or based on postmarket experience (including adverse event reporting) and used to determine whether any aspect of the design should be modified. Standards and guidance addressing conduct of risk management activities such as risk assessment, risk control, risk reporting, and risk review for devices and drugs are appropriate references to inform these activities for a combination product.61 Also, risk assessment and management activities performed for a drug constituent part under pharmaceutical development practices may become elements of the overall risk analysis for a combination product. Manufacturers must establish and maintain design transfer procedures to ensure effective translation of design specifications into production methods and procedures.62 Design transfer is the bridge between the design of the product and the manufacturing process to make the commercial product. there are differences, the manufacturer must justify why design validation results are valid for the production units, lots, or batches.” For a combination product, this documentation and justification must account for considerations arising from inclusion of a drug or biological product, including equivalence of the manufacturing process for the drug/biologic constituent part or the combination product as a whole. The rationale for equivalence should be documented and may require bridging studies, completion of comparability protocols, or other test data to support that products used for design validation are representative of the combination product that the manufacturer intends to market. 59 For more information on human factors for combination products, see Draft Guidance for Industry an FDA Staff Human Factors Studies and Related Clinical Study Considerations in Combination Product Design and Development (February 2016). When finalized, this document will represent the Agency’s current thinking on this topic. 60 21 CFR 820.30(g). 61 For more information on risk analysis and risk management see, e.g., ISO 14971 Risk Management – Medical Devices and FDA Guidance for Industry Q9 Quality Risk Management (June 2006). 62 21 CFR 820.30(h). Contains Nonbinding Recommendations Manufacturers are required to have procedures to ensure that any changes to design requirements are identified, documented, validated or verified where appropriate, reviewed, and approved prior to implementation.63 Change controls apply once initial design inputs have been approved by the manufacturer.64 A change control process is essential to manage design changes both during the original design process for the combination product and after the design has been transferred to manufacturing. 65 The records of these changes must be maintained as part of the design history file (21 CFR 820.30(j)). They create a history of the evolution of the design, which can be important when investigating failures or evaluating the appropriateness of proposed, additional changes to the product. A manufacturer may choose to use different processes for premarket (as opposed to postmarket) changes to accommodate the rapid, iterative design process that is often present during investigational stages, so long as the design change and transfer process is compliant with 21 CFR 820.30. The Design History File (DHF) for a combination product captures all design issues relating to the combined use of the constituent parts. The DHF may not need to document design and development planning for established characteristics of the individual constituent parts, for example the safety and effectiveness of a drug constituent part of a co-packaged combination product, if that drug constituent part was previously approved for the same indication. If a finished device, drug, or biological product is purchased, the combination product manufacturer is not required to retrospectively “design” that constituent part with respect to such previously reviewed characteristics. Rather, the combination product manufacturer should understand the constituent part’s existing design specifications thoroughly in order to perform design controls properly for its use in the combination product.66 If a separately developed drug, device, or biological product constituent part needs to be modified to be used in the combination product, the manufacturer must assess what design control activities must be performed to ensure safety and effectiveness of the combination product (e.g., new formulation of a drug or new features of a device).67 It is appropriate for a DHF for a combination product to leverage and cross-reference developmental data and data systems. Manufacturers transitioning from drug development to combination product development should evaluate existing development documentation and systems and assess what, if any, changes may be needed to demonstrate compliance with 21 CFR 820.30. Manufacturers should be able to explain to FDA in premarket submissions and in inspections how their practices and terminology align with the requirements in 21 CFR 820.30, 63 21 CFR 820.30(i). 64 61 FR 52621, Comment 87. 65 21 CFR 820.30(h). 66 Similarly, if a combination product manufacturer is purchasing device components for inclusion in a combination product, and the device component supplier is manufacturing a finished device from the same or similar components and is therefore subject to the device QS regulation, the combination product manufacturer may be able to leverage elements of that supplier’s design controls in developing the overall design controls for the combination product. The information leveraged should typically be covered by a formal agreement between the combination product manufacturer and supplier defining maintenance and sharing of design information. If the component supplier does not itself comply with the device QS regulation, the combination product manufacturer’s design control activities for the device constituent part will likely need to be more extensive. 67 21 CFR 820.30(c). Contains Nonbinding Recommendations and be able to identify and readily access for FDA inspection all documentation needed to demonstrate compliance with design control requirements. If a manufacturer is evaluating the adequacy of their design controls and documentation for a currently marketed combination product, it may be helpful to review premarket submissions, the product risk profile, and postmarket experience for the combination product. The results of this review can inform decisions on whether additional testing and documentation is required. FDA encourages combination product manufacturers to direct specific questions on the adequacy of their design control measures and documentation to the lead center for their products, and OCP as needed, for assistance. For further information on design controls, see the preamble to the final device QS regulation.68 3. Purchasing controls (21 CFR 820.50) Manufacturers of single-entity and co-packaged combination products that include a device constituent part must control purchased products69 and services as described in 21 CFR 820.50. They must establish such purchasing controls for products received at their facility for use in the manufacture of the combination product, for all suppliers of these products, and for suppliers of services obtained (such as terminal sterilization conducted by an outside entity) (21 CFR 820.50(a)). Facilities that have previously manufactured only drugs, rather than devices or combination products, will likely have relevant procedures in place in accordance with part 211, subpart E. However, if these procedures do not demonstrate compliance with the specific requirements of 21 CFR 820.50, they must be augmented to do so. Manufacturers must evaluate potential suppliers and define the type and extent of control to be exercised over them based on the evaluation results.70 Manufacturers may design and conduct such evaluations based on factors such as the risks associated with the supplied product or service and complexity of the specifications for it. Manufacturers must establish and maintain records of acceptable suppliers for purchased products and services,71 and establish and maintain data that clearly describe or reference the specified requirements for products and services received (e.g., contracts with relevant terms).72 One way to facilitate purchasing control is the careful structuring of purchasing agreements with suppliers. Where possible, such agreements are used to ensure that the combination product manufacturer is notified of changes to the products, the manufacturing process, or the services being provided.73 Such notice of changes facilitates compliance not only with purchasing control duties, but also, potentially, with other regulatory requirements, including design control obligations to complete additional design verification testing to address 68 See Medical Devices; Current Good Manufacturing Practice (CGMP) Final Rule; Quality System Regulation, 61 FR 52602-52662 (October 7, 1996). 69 Under 21 CFR 820.3(r), the term “product” includes components and manufacturing materials, in addition to in- process and finished articles. 70 See 21 CFR 820.50(a)(2). 71 See 21 CFR 820.50(a)(3). 72 See 21 CFR 820.50(b). 73 See 21 CFR 820.50(b). Contains Nonbinding Recommendations the change (e.g., to ensure that the purity and stability of a drug constituent part is maintained when the materials change in a device constituent part that is also a container closure). If it is not possible to obtain such notice, the combination product manufacturer should implement additional controls to ensure that changes are identified and appropriate measures are taken. The combination product manufacturer should ensure agreements are appropriately structured, whether through direct agreements with suppliers and contract manufacturers or through confirmation that such parties have adequate agreements between themselves. For example, a combination product manufacturer may choose to maintain a change agreement with a material supplier who provides material directly to a contract manufacturing facility. Note that regardless of the nature of purchasing controls, combination product manufacturers must comply with the testing requirements under 21 CFR 211.84 with respect to drug components, and product containers and closures (see IV.B.1 below). 4. Corrective and Preventive Actions (21 CFR 820.100) Manufacturers of co-packaged or single-entity combination products that have a device constituent part must establish and maintain procedures for implementing CAPA in accordance with 21 CFR 820.100. Relevant requirements in the drug CGMPs include 21 CFR 211.192 and 21 CFR 211.180(e).74 Manufacturers of the combination product must undertake CAPA measures, when required, for issues arising at their facilities. All relevant manufacturers should participate in cross-facility efforts, as appropriate, to determine the root-cause of problems and the appropriate measures to correct such problems and prevent recurrence. Manufacturers of combination products should document these activities.75 The CAPA process for combination products also should consider implications of corrective and preventive actions for all constituent parts and for the combination product as a whole. While combination product manufacturers have flexibility in coordinating CAPA systems across facilities, they maintain responsibility for ensuring that the 21 CFR 820.100 requirements are met. Manufacturers should ensure that an appropriately comprehensive review of activities is undertaken at relevant facilities to determine the cause of existing or potential problems, which could include manufacturing problems, deviations, or nonconformities for a constituent part or the combination product as a whole. The manufacturer should have appropriate mechanisms in place to ensure that issues are identified, action(s) needed to correct and prevent recurrence are taken, and necessary changes are implemented. The manufacturer should take appropriate measures, which may include CAPAs, with regard to all relevant manufacturing steps at all relevant facilities to correct problems and to prevent or mitigate them going forward. 74 See also FDA Guidance for Industry, Investigating Out-of-Specification (OOS) Test Results for Pharmaceutical Production (October 2006), which discusses appropriate identification, assessment, and investigation of OOS results for drug products, including results obtained under 21 CFR 211.165 (a provision specified in 21 CFR part 4). Quality data from OOS investigations and any related corrective actions should be addressed through the combination product manufacturer’s quality system. Also, FDA guidance for industry, ICH Q10 Pharmaceutical Quality System (April 2009), includes additional recommendations for preventive actions and, when failures or other issues occur, corrective actions. 75 For further guidance, see the preamble to the device QS regulation at 61 Fed. Reg. at 52633-52635, Comments 158-166. Contains Nonbinding Recommendations B. Provisions from the drug CGMPs specified in 21 CFR 4.4(b)(2) This section provides a brief description of the provisions from the drug CGMPs with which single-entity and co-packaged combination product manufacturers must demonstrate compliance when using the device QS regulation-based streamlined approach established under 21 CFR 4.4(b)(2), including considerations specific to applying these requirements to combination products. This discussion is not meant to be a comprehensive analysis, but rather to help manufacturers—particularly device manufacturers, who may be less familiar with drug CGMPs—understand the purpose and basic elements of the provisions of the drug CGMPs specified in 21 CFR 4.4(b)(2), as well as to direct such manufacturers to additional guidance. The specified provisions of the drug CGMPs include requirements for testing and other verification procedures for batches or lots, whether of drug components, drug containers and closures, drug constituent parts, or the whole combination product. Combination product manufacturers should establish procedures defining a “batch” or “lot” in all phases of production and describe all batch and lot numbering systems used for incoming material, in-process material, and finished products. These procedures allow manufacturers to connect specific batches or lots of constituent parts, components, and in-process material to the specific batches or lots of the combination product for which they are used. These procedures enable traceability of sampling and testing, packaging, and labeling activities, and can be important when assessing and responding to issues including complaints and adverse events. Master production and control records should be designed to enable this traceability. An explanation of batch and lot definitions, controls, and tracking should be available for review on inspection. 1. Testing and approval or rejection of drug product components, containers, and closures (21 CFR 211.84) Drug product components, containers, and closures must be tested in accordance with 21 CFR 211.84. A drug component is any ingredient intended for use in the manufacture of a drug product, including those that may not appear in the drug product.76 A container closure system is the sum of packaging components that together contain and protect the drug product. This includes primary packaging components and also secondary packaging components if the latter are intended to provide additional protection to the drug product.77 Examples of packaging components are ampules, vials, screw caps, stoppers, and stopper overseals. As discussed in section III.C.3, container closure systems and elements of container closure systems may also be regulated as devices. Combination product manufacturers do not need to demonstrate compliance with this provision for device constituent parts or materials used in the manufacture of a device constituent part, unless the device constituent part is also the drug container or closure or a part thereof. For example, for a CGMP operating system established in accordance with 21 CFR 4.4(b)(2) (device 76 See 21 CFR 210.3(b)(3). 77 See the Guidance for Industry on Container Closure Systems for Packaging Human Drugs and Biologics: Chemistry, Manufacturing, and Controls Documentation (May 1999). Contains Nonbinding Recommendations QS regulation-based streamlined approach), if materials are used solely for manufacture of a device constituent part that is not part of the drug container or closure (e.g., a co-packaged device), the manufacturer need only demonstrate compliance with applicable provisions of part 820 to show appropriate control of such materials for that device constituent part (including 21 CFR 820.30, 820.50, 820.80, and 820.86). 21 CFR 211.84 details how to sample, test, examine, and accept or reject drug product components, containers, and closures. In lieu of such testing, 21 CFR 211.84 allows for some reliance on a supplier’s report of analysis, provided that certain identity testing is conducted and that the reliability of the supplier’s analysis is established by the manufacturer through appropriate validation of the testing results at appropriate intervals. These duties augment and elaborate upon acceptance activity requirements expressly established under 21 CFR 820.80. Accordingly, if a facility already has 21 CFR 820.80-based acceptance procedures, it would be appropriate to provide for compliance with 21 CFR 211.84 requirements by augmenting these existing procedures as needed to incorporate 21 CFR 211.84 compliant measures. Each lot of drug components, containers, and closures must be withheld from use until it has been sampled, tested, or examined, as appropriate, and released for use by the quality control unit.78, The samples collected for each lot must be representative of the entire lot.79 These representative samples must be collected and tested or examined in accordance with the procedures specified in 21 CFR 211.84. These procedures require, among other things, appropriate sampling technique to prevent contamination of the sampled component or of other materials.80 In addition, the number of containers to sample and the amount of material to be taken from each container must be based on appropriate criteria (e.g., component variability, confidence levels, degree of precision desired, past quality history of the supplier, and the quantity needed for analysis).81, 82 2. Calculation of Yield (21 CFR 211.103) Actual yields and percentages of theoretical yield for the drug constituent part(s) of a combination product must be determined as described in 21 CFR 211.103. Excess or low yields may suggest problems in the production process, including equipment failure, that may affect product quality and that may not be discovered, or not be discovered as quickly, using sample- based release testing alone. Actual yield discrepancies outside of established and documented allowable variation from theoretical yield should be investigated. 78 See 21 CFR 211.84(a). 79 See 21 CFR 211.84(b). 80 See 21 CFR 211.84(c). 81 See 21 CFR 211.84(b). 82 Some references that may be useful for sampling by variables and sampling by attributes include “American Standards for Testing and Materials (ASTM) Standard E2709, Standard Practice for Demonstrating Capability to Comply with an Acceptance Procedure” and “ASTM Standard E2334, Standard Practice for Setting an Upper Confidence Bound For a Fraction or Number of Non-conforming Items, or a Rate of Occurrence for Non- conformities, Using Attribute Data, When there is a Zero Response in the Sample,” respectively. Contains Nonbinding Recommendations Yield calculation requirements under 21 CFR 211.103 apply to the drug constituent parts of combination products. Data on the number of device constituent parts and components used and lost during the manufacture of a combination product may be necessary to ensure appropriate control of the manufacturing process in accordance with 21 CFR 211.100 or 21 CFR 820.70, but yield calculation in accordance with 21 CFR 211.103 is not required for device constituent parts. However, problems with the device constituent part during combination product manufacturing may affect drug yield and result in further investigation. For example, prefilled syringes that are rejected due to nonconformity of the syringe needle may result in corresponding loss of drug from the batch/lot. Any loss would be captured as part of the yield calculations for the drug constituent part, and investigation of the cause of that loss should identify the manufacturing problem that is leading to these device nonconformities. Yield determinations must be made at the conclusion of each appropriate phase of manufacturing, processing, packaging, and holding for the drug constituent part(s) and for the combination product as a whole.83 Accordingly, calculation of yield should be determined at each phase at which component, in-process material, or product loss may occur, including during the formulation of the drug prior to incorporation into the combination product, during incorporation into the combination product (e.g., filling or coating), and, possibly, during the packaging process. These calculations must be performed by one person and independently verified by a second person, unless the yield is calculated by automated equipment in accordance with section 21 CFR 211.68, in which case it must be independently verified by one person.84 For each appropriate phase of the manufacturing process performed, the formula used and the data generated for the yield calculation for the phase should be documented. For manufacturers operating under a device QS regulation-based system, documentation of yield calculations may be incorporated into existing part 820 documentation (for example, as part of the device history record, 21 CFR 820.184). These records should include actual yields, percentages of theoretical yields, and the maximum and minimum percentages of theoretical yield beyond which investigation is required for the drug constituent part, including as it is processed and combined with the other constituent part(s) of the combination product. If a third party is manufacturing the drug for the combination product, that manufacturer is responsible for complying with the calculation of yield requirement at the appropriate phases of the drug manufacturing process it performs, but the combination product manufacturer is responsible for ensuring that the supplier satisfies these requirements, as a part of the combination product manufacturer’s purchasing controls for its product in accordance with 21 CFR 820.50. 3. Tamper-evident packaging requirements for over-the-counter human drug products (21 CFR 211.132) Manufacturers of OTC combination products must comply with the requirements of 21 CFR 211.132. The required controls include tamper-evident packaging and labeling alerting 83 See 21 CFR 211.103. 84 See 21 CFR 211.103. Contains Nonbinding Recommendations customers to these protective features of the product’s packaging. These controls are important to help improve the security of OTC combination product packaging and help ensure the safety and effectiveness of OTC combination products. For single-entity combination products, tamper-evident packaging requirements apply to the packaging for the combination product as a whole. For co-packaged combination products, these requirements can be met through appropriate packaging of the drug constituent part(s) within the larger co-package so long as such an approach is otherwise permissible under the packaging and labeling requirements applicable to that combination product. Certain combination products may be exempt from OTC tamper-evident packaging requirements85 (e.g., toothpaste co-packaged with a toothbrush) or from bearing a statement of tamper-evident features on the package86 (e.g., aerosol saline nasal spray). An exemption from tamper-evident packaging and labeling requirements for an OTC combination product may be requested in accordance with 21 CFR 211.132(d). If the manufacturer makes changes to packaging and labeling of an approved OTC product to comply with the requirements of 21 CFR 211.132, it must notify the lead center for the combination product before distributing it.87 4. Expiration dating (21 CFR 211.137) 21 CFR 211.137 helps ensure that drug products (drug constituent parts in the case of combination products) meet applicable standards of identity, strength, quality, and purity at the time of use, by requiring that the product labeling bear an expiration date. This date must take into account any storage conditions stated in the labeling and be based on appropriate stability testing as described in 21 CFR 211.166 (See section IV.B.6).88 The expiration dating also should take into account any other applicable shelf-life considerations (e.g., for a product that is to be provided sterile, the length of time that its packaging material can be ensured to retain its integrity and, thereby, maintain a sterile barrier). In some cases, the drug constituent part might not have an expiration date because current regulations exempt it from this requirement.89 Similarly, some device constituent parts may not have expiration dates. When expiration dating is required, the constituent parts of combination products may have individual expiration dates or an expiration date for the entire combination product may be appropriate. Generally, when constituent parts of a co-packaged combination product can be used independently, expiration dating should be addressed separately for each constituent part. If a single expiration date is listed for a co-packaged combination product, this date should be the earliest expiration date/shortest shelf-life for any constituent part. The expiration date for a combination product may be shorter than the expiration date or shelf life for its constituent 85 See 21 CFR 211.132(b)(1). 86 See 21 CFR 211.132(c)(1). 87 See 21 CFR 211.132(e). 88 See 21 CFR 211.137(b). 89 See 21 CFR 211.137. Contains Nonbinding Recommendations part(s) if marketed independently. Reasons for a shorter expiration period could include interactions between the constituent parts when combined, the effects of additional manufacturing steps, or other differences arising from the combination of the constituent parts. 5. Testing and release for distribution (21 CFR 211.165) Testing and release for distribution are critical in drug product manufacture and quality control. 21 CFR 211.165 requires that an appropriate laboratory determination of satisfactory conformance to final specifications (including the identity and strength of each active ingredient) is made for each batch of drug product prior to release. 21 CFR 211.165 also requires appropriate laboratory testing, as necessary, of each batch of a drug product required to be free of objectionable microorganisms. In addition, sampling and testing plans must be described by written procedures.90 Accordingly, manufacturers must test each batch of their combination product to determine satisfactory conformance to final written specifications for the drug constituent part.91 For single-entity combination products, laboratory testing must be performed on every batch of the combination product; for co-packaged combination products, laboratory testing must be performed on every batch of the drug constituent part(s). 92 This testing ensures that all batches meet appropriate specifications for their approval and release.93 A detailed listing of all the tests performed and the acceptance criteria used should be maintained and be available for inspection.94 In some cases, for single-entity combination products, in lieu of using actual units from a finished combination product batch for testing to determine whether the drug constituent part meets final specifications, manufacturers may wish to use samples that are not finished combination products (but that are representative of the finished combination product with respect to the characteristics and attributes being tested). The Agency does not intend to object to such an approach where the manufacturer can establish, including where appropriate through bridging studies and other quantitative means, that any differences in the manufacturing process for the samples and the finished combination product do not affect the drug constituent part. Such approaches should be supported by appropriate justification and data and discussed with the lead Center, and OCP as needed. 90 See 21 CFR 211.165(c). 91 See 21 CFR 211.165(a). 92 See 21 CFR 211.165(a). 93 See 21 CFR 211.165(a), (b). 94 21 CFR 211.165 addresses testing and release for “drug products”; appropriate controls for intermediate stages (e.g., in-process materials) in the manufacture of combination products are addressed under separate provisions of the drug CGMPs and device QS regulation that are not specified in part 4. If a manufacturer operates under a streamlined approach under 21 CFR 4.4(b), it should take into consideration the materials and manufacturing steps for the combination product as a whole in determining how to demonstrate compliance with obligations for in- process materials, and may find it helpful to refer to the corresponding requirements under the other regulation (that it did not choose as the base for its CGMP operating system). For example, if the facility operates under a device QS regulation-based streamlined approach, in determining how to comply with duties under 21 CFR 820.70, 820.80, and 820.86 for the combination product as a whole, reference to 21 CFR 211.110 and guidance relating to in-process materials for drug products may facilitate appropriate consideration of the controls for drug constituent parts. Contains Nonbinding Recommendations If one facility is manufacturing a drug product as a constituent part to be supplied to another facility or manufacturer for inclusion in a co-packaged combination product, appropriate and adequate laboratory testing should be conducted by the drug product manufacturing facility prior to release of the drug constituent part(s) for distribution in accordance with 21 CFR 211.165. For combination products that include a device constituent part, the combination product manufacturer is responsible for ensuring through purchasing controls in accordance with 21 CFR 820.50 that the drug constituent part conforms to specified requirements, including laboratory testing requirements. Appropriate testing or examination (such as visual inspection) should also be conducted throughout the remaining manufacture of the finished co-packaged combination product to ensure that the drug constituent part(s) continues to conform to its final specifications. 6. Stability testing (21 CFR 211.166) 21 CFR 211.166 requires a testing program designed to assess the stability characteristics of drug products. Furthermore, 21 CFR 211.166 sets forth required elements of the testing program, including elements concerning sample size, storage conditions for samples retained for testing, and other elements related to testing methodology and frequency.95 Stability testing is performed to determine appropriate storage conditions and expiration dates (see section IV.B.4). Among other considerations, this testing must enable evaluation of any effects on the stability of the drug due to storage in its marketed container closure system, which may be a device constituent part (or component of a device constituent part).96 For a single-entity combination product, testing must be performed on the drug constituent part as incorporated into the finished combination product.97 The Agency does not intend to object to the use of bracketing and matrix approaches for stability studies where the approach has been adequately justified and, where applicable, reviewed by FDA.98 The Agency also does not intend to object to leveraging stability data for an already marketed combination product during new product development, with adequate justification and, where applicable, review by FDA. In particular, for purposes of establishing an expiration date for a new combination product, such leveraging may be acceptable if the new product represents a modification to the existing marketed combination product that would not impact the stability of the drug constituent part (for example, a change to the catheter length for a 95 For further information on stability testing considerations, see, for example, the Guidance for Industry on Q1A(R2) Stability Testing of New Drug Substances and Products (November 2003). 96 See 21 CFR 211.166(a)(4). 97 See 21 CFR 4.3, 4.4, and 211.166. In addition, while stability testing requirements under 21 CFR 211.166 do not apply to device constituent parts of a co-packaged combination product, under design control requirements, testing must be performed to demonstrate that device functionality (i.e., mechanical performance of the device constituent part) is maintained until the specified expiration date for the combination product. See 21 CFR 820.30. 98 For further information on bracketing and matrixing considerations, see, for example, the Guidance for Industry on Q1D Bracketing and Matrixing Designs for Stability Testing of New Drug Substances and Products (January 2003). Contains Nonbinding Recommendations drug-coated balloon, where the balloon component remains unchanged) and is not otherwise material to the expiration date.99 If a new product has minor differences that present a low risk of affecting the stability of the drug (for example, a different size of a drug-coated balloon that is bracketed within the balloon size matrix previously used to establish the expiration date, and without other changes relevant to stability, for example, in the coating application process),100 the Agency does not intend to object, in appropriate cases, to: i) the use of previously generated stability data for the existing product (or family of products) to support reduced stability data requirements for the new product (for example, generation of only short-term accelerated data) or ii) to incorporating the product into the ongoing stability program for the existing marketed product(s), provided that stability data trends and stability history for the existing product or product family are sufficiently robust for this purpose. Applicants should contact the lead center for their product, or OCP as needed, regarding such approaches.101 The need for new stability studies should be evaluated when there are changes to any constituent part of a combination product. For example, changes to the manufacturing process, including changes based on the size or shape of the device constituent part that holds the drug or that is coated with the drug, or changes in material of construction of such a device constituent part, may impact drug stability. Manufacturers are responsible for establishing and managing the stability program. If a combination product manufacturer purchases a drug product from another manufacturer for inclusion in its co-packaged combination product, the combination product manufacturer is responsible for ensuring the stability of the drug product as marketed in the co-packaged product through appropriate mechanisms, such as by implementing purchasing controls to ensure the adequacy of the drug product manufacturer's stability testing or by conducting additional stability testing (see 21 CFR 820.50). Documentation of such oversight should be included in the CGMP records. If a drug constituent part of a co-packaged combination product has an expiration date, the combination product manufacturer may be able to rely on that labeled expiration date in lieu of conducting new stability studies, if it can be documented that any additional manufacturing operations conducted on the co-packaged product would not be expected to impact the constituent part, including its container-closure system. 99 Note that shelf life testing to evaluate the impact of the modification to the device constituent part may still be appropriate. 100 This might also be the case for a family of products that vary in shape from one another, provided, again, that these variations pose a low risk. 101 Note that shelf life testing to evaluate the impact of a modification on the device constituent part may still be appropriate. Contains Nonbinding Recommendations 7. Special testing requirements (21 CFR 211.167) 21 CFR 211.167 establishes requirements for batch testing applicable to drug products having particular characteristics. Specifically, 21 CFR 211.167(a) requires appropriate laboratory testing of drug products purporting to be sterile and/or pyrogen-free to determine conformance with such requirements; 21 CFR 211.167(b) requires appropriate testing of ophthalmic ointments to determine conformance to specifications regarding the presence of foreign particles and harsh or abrasive substances; and 21 CFR 211.167(c) requires appropriate laboratory testing of controlled-release dosage forms to determine conformance to the specifications for the rate of release of each active ingredient. A special testing requirement specified in 21 CFR 211.167 applies to a combination product only if the combination product or a drug constituent part of it falls into one or more of the three categories described above. Special testing may be required for the drug constituent part, or the combination product as a whole, depending on the product. With respect to 21 CFR 211.167(a), batch testing requirements would apply both to the drug constituent part and to the finished combination product for a single-entity combination product (such as a prefilled syringe) to ensure the combination product is sterile and pyrogen- free when distributed. In contrast, if a vial of a vaccine were co-packaged with an empty syringe, the requirements in 21 CFR 211.167(a) would apply only to the vial of vaccine.102 A similar analysis would apply for compliance with 21 CFR 211.167(b) for a single-entity versus a co-packaged combination product that includes an ophthalmic ointment. For purposes of conducting pyrogen and endotoxin testing, it may be permissible in some circumstances to define a “batch” based on the finished drug product rather than the finished combination product. For example, it may be acceptable to define a batch as a subcomponent of the combination product that incorporates the drug constituent part. However, the viability of such an approach would depend on many factors including: appropriate upstream controls to reduce/limit pyrogens and endotoxins; the chemical or materials-mediated pyrogenicity of the constituent parts, and the risks of pyrogen and endotoxin introduction to the combination product by manufacturing operations that occur after the step at which the batch is defined. For instance, for some products, it may be possible to test material for endotoxin during an in-process manufacturing step and there may be no need to test for endotoxins in the single entity combination product. 21 CFR 211.167(c) would apply both to a controlled-release drug constituent part of a co- packaged combination product and also to a controlled release single-entity combination product, to confirm rate of release of the active ingredient. For example, a transdermal drug patch or drug- 102 The requirements related to sterility and non-pyrogenicity of the empty syringe would be addressed through compliance with other provisions (for example, process controls requirements under 21 CFR 211 or 21 CFR 820, design controls requirements under 21 CFR 820.30, and purchasing controls requirements under 21 CFR 820.50). For additional information on pyrogen and endotoxin testing, see the Guidance for Industry on Pyrogen and Endotoxins Testing: Questions and Answers (June 2012)). Contains Nonbinding Recommendations eluting disc or stent would be subject to 21 CFR 211.167(c). As with drugs and devices, parametric release may be acceptable for some combination products when supported by appropriate data. Such approaches should be discussed with the lead Center, or OCP as needed, prior to implementation and included in premarket submissions.103 8. Reserve samples (21 CFR 211.170) Reserve samples are needed to help ensure the safety and effectiveness of combination products in distribution, as they are for drugs and biological products. They are used, for example, to address certain product complaints, evaluate stability concerns, and assess the causes of adverse events. The reserve sampling requirements of 21 CFR 211.170 must be met for the drug constituent parts of combination products. Under 21 CFR 211.170, reserve samples must be kept that are representative of both: • • each lot of the active ingredient (21 CFR 211.170(a)), and each lot or batch of the drug product (21 CFR 211.170(b)). All reserve samples must consist of at least twice the quantity necessary to perform all required tests, except those for sterility and pyrogenicity.104 Furthermore, reserve samples of drug products must be retained and stored under conditions consistent with product labeling and stored in the same immediate container-closure system in which the drug product is marketed or in one that has essentially the same characteristics.105 Accordingly, single-entity and co-packaged combination product manufacturers alike must keep reserve samples of each lot of the active ingredient, if any, that they receive, in whatever form it arrives at their facility (e.g., as bulk active pharmaceutical ingredient or incorporated into an in-process material). For co-packaged combination products, the requirement to keep reserve samples of drug products can be met by maintaining samples of the drug constituent part in its immediate container-closure system, without the need to retain any samples of the device or portions of it.106 For single-entity combination products, the drug product reserve samples should be of the drug constituent part in or upon the device constituent part or components thereof that come into contact with the drug product as packaged for distribution. 103 See, for example, Guidance for Industry Submission of Documentation in Applications for Parametric Release of Human and Veterinary Drug Products Terminally Sterilized by Moist Heat Processes (February 2010) . 104 21 CFR 211.170. Stability is not required to be assessed on every drug batch. See 21 CFR 211.166(b). Drug product reserve samples must be visually examined at least once a year while in storage as an ongoing check on the quality of the material in distribution, unless a visual examination would affect the integrity of the reserve sample. 21 CFR 211.170(b). 105 21 CFR 211.170(b). 106 See 21 CFR 211.170(b). Contains Nonbinding Recommendations Manufacturers must examine drug product samples for deterioration, investigate evidence of deterioration, and record and maintain the results of such examination.107 Drug product reserve samples generally must be maintained for 1 year after the expiration date for the drug product; different time periods apply to certain radioactive and OTC products.108 Active ingredient samples generally must be kept for 1 year after the expiration date for the last lot of the combination product containing the active ingredient.109 Accordingly, manufacturers should retain samples from each lot of bulk drug substance for 1 year after the expiration date of the last lot of the combination product that uses that lot of the active ingredient. Combination product manufacturers may choose to have their reserve samples of the API, drug/biologic constituent part, or finished combination product at a location other than the combination product manufacturing facility. In these cases, the combination product manufacturer should have appropriate controls in place to ensure that requirements under 21 CFR 211.170 continue to be met. Such controls could include agreements with the facilities holding the reserve samples to ensure appropriate storage conditions, access to the samples by the combination product manufacturer, ability to analyze the reserve samples, if needed, and maintenance of adequate numbers of samples for each lot. For combination products, it is generally sufficient to maintain the appropriate number of reserve samples from each lot of the active ingredient and from each lot or batch of the drug constituent part in the immediate container/closure in which it is marketed. For single-entity combination products, the device constituent part may be the drug’s container/closure or a part of it, or the container/closure may be distinct from the device constituent part. For a drug-eluting stent or disc, or a prefilled syringe, for example, reserve samples should generally be kept of the entire combination product. In contrast, if, for example, the combination product consists of an injector system (device constituent part) into which the user inserts a prefilled cartridge containing the drug, reserve samples of the prefilled cartridge alone would generally suffice to comply with the drug product sample retention requirements. An injector may need to be available, however, to enable testing of reserve samples. Manufacturers that want to retain and store reserve samples that are representative of, but not identical to, a finished drug constituent part or combination product, as appropriate, should include adequate justification and data to support that: • Any differences in the manufacturing process for the reserve sample and the finished combination product do not affect the drug constituent part (see discussion in IV.B.5 above); • The immediate container/closure has essentially the same characteristics as the immediate container/closure for the drug as packaged in the combination product for distribution (if the actual immediate container closure is not being used), and • The proposed representative samples are suitable for all required testing of the drug constituent part for which those reserve samples are being kept. 107 See 21 CFR 211.170(b). 108 See 21 CFR 211.170(b). 109 See 21 CFR 211.170(a). Contains Nonbinding Recommendations It may be possible to keep properly defined and validated surrogates for some testing while retaining complete samples of the combination product for other tests as an alternative to retaining complete samples for all testing. Bracketing and matrixing approaches also may be acceptable, as may use of samples from representative lots of a larger batch (for example, representative samples of each size from within a broadly defined batch that includes multiple sizes from the same family of coated combination products).110 Manufacturers considering use of novel approaches to comply with reserve sampling requirements are advised to discuss them with the lead center for their combination product, or OCP, as needed. C. Combination products that include biological products and HCT/Ps In addition to complying with drug CGMP and device QS regulation requirements as applicable in accordance with part 4, a manufacturer of a combination product that contains a biological product or an HCT/P must comply with the requirements that would apply to the biological product or HCT/P if it were not part of a combination product. 1. Complying with CGMP requirements for biological products It is important to remember that a biological product regulated under section 351 of the PHS Act is also, by definition, a drug or a device. Accordingly, in addition to the requirements in parts 600 through 680, a biological product is always either subject to the drug CGMPs or subject to the device QS regulation, regardless of whether the biological product is a constituent part of a combination product. The CGMP requirements for biological products in parts 600 through 680 augment the drug CGMPs and device QS regulation to ensure adequate consideration of issues for biological products. The CGMP requirements for biological products in parts 600 through 680 address the particular challenges biological products pose, including challenges arising from their relative complexity. For biological products, consistency of manufacturing procedures can, in fact, be a primary means by which to ensure the safety, purity, and potency of the product. The CGMP requirements for biological products in parts 600 through 680 must be satisfied if a combination product includes a biological product constituent part. However, many requirements in parts 600 through 680 are applicable only to certain types of biological products. For example, while part 600 facially addresses biological products in general, only products manufactured using a spore-forming microorganism would be subject to 21 CFR 600.11(e)(3) (work with spore-forming microorganisms). Similarly, only blood and blood components are subject to the CGMP requirements for such products under part 606. In addition, the CGMP requirements for biological products applicable to a given product can vary based on considerations specific to the particular biological product. 110 FDA notes that approaches that depend upon retaining samples against more broadly defined batches may increase the number of distributed products implicated when corrective actions are necessary to address postmarket issues. Contains Nonbinding Recommendations In short, the specific requirements in parts 600 through 680 that must be met to comply with 21 CFR 4.3 and 4.4(c) for a particular combination product that includes a biological product constituent part will depend on the type of biological product it includes. The Agency welcomes the opportunity to discuss these requirements with manufacturers to ensure sound, effective CGMP operating systems. If manufacturers have questions regarding these requirements, they may contact the lead center for the combination product or OCP, as needed, for assistance. 2. Complying with CGMPs for HCT/Ps An HCT/P that is not regulated solely under section 361 of the PHS Act and Part 1271 is also regulated as a drug, device, or biological product. 111 The drug CGMPs, device QS regulation, and the requirements in parts 600 through 680 may apply to an HCT/P depending on whether the product is regulated as a drug, device, or biological product.112 CGMPs and the CGTPs for HCT/Ps supplement one another and do not supersede each other unless the regulation specifically provides otherwise. In the event that a regulation in part 1271 is in conflict with a requirement in parts 210, 211, 600 through 680, or 820, the regulations more specifically applicable to the product in question will supersede the more general.113 The CGTPs, including donor eligibility requirements for the manufacture of HCT/Ps under part 1271, are designed to prevent the introduction, transmission, and spread of communicable diseases, and thereby are essential to protecting the public health. Accordingly, the current CGTPs apply to combination products that include an HCT/P. However, requirements under some sections of part 1271 overlap with the requirements under the drug CGMPs and the device QS regulation. These overlaps are addressed in part 1271 and in the Guidance for Industry on Current Good Tissue Practice (CGTP) and Additional Requirements for Manufacturers of Human Cells, Tissues, and Cellular and Tissue-Based Products (HCT/Ps) (CGTP Guidance). 111 The HCT/P regulations at part 1271 distinguish between HCT/Ps regulated solely under section 361 of the PHS Act (42 U.S.C. 264) and part 1271 and those that are also regulated as drugs, devices, and/or biological products. Section 1271.10 provides that an HCT/P is regulated solely under section 361 of the PHS Act if it meets all of the following criteria: (1) it is minimally manipulated; (2) it is in intended for homologous use only, as reflected by the labeling, advertising, or other indications of the manufacturer's objective intent; (3) manufacturer of the HCT/P does not involve the combination of the cells or tissues with another article (other than water, crystalloids, or a sterilizing, preserving, or storage agent) provided that the addition of water, crystalloids, or the sterilizing, preserving, or storage agent does not raise new clinical safety concerns with respect to the HCT/P; and (4) Either: (i) The HCT/P does not have a systemic effect and is not dependent upon the metabolic activity of living cells for its primary function; or (ii) The HCT/P has a systemic effect or is dependent upon the metabolic activity of living cells for its primary function, and is for autologous use, is for allogeneic use in a first-degree or second-degree blood relative; or is for reproductive use. Refer to 21 CFR 3.2(e), 1271.10, 1271.15, and 1271.20, to determine whether an HCT/P is regulated as a drug, device, or biological product constituent part of a combination product. 112 See 78 FR 4317. 113 See 21 CFR 1271.150(d). Also see the Guidance for Industry on Current Good Tissue Practice (CGTP) and Additional Requirements for Manufacturers of Human Cells, Tissues, and Cellular and Tissue-Based Products (HCT/Ps) (December 2011). Contains Nonbinding Recommendations 21 CFR 1271.150(d) explains that for HCT/Ps regulated as biological products, drugs or devices, the procedures contained in subpart D and in subpart C of part 1271 and the procedures contained in parts 210, 211, and 820, supplement one another. As a consequence, compliance with certain provisions of part 211 or 820 may also constitute partial or complete compliance with certain provisions of part 1271. However, for certain issues, the CGTP requirements would require additional manufacturing practices. The adjustments that might need to be made to an existing CGMP operating system to be fully compliant with the part 1271 CGTP requirements for a combination product that includes an HCT/P may differ if the system being augmented is a drug manufacturing system under 21 CFR 211, a device manufacturing system under part 820, or a combination product manufacturing system that demonstrates compliance with 21 CFR 211 and 21 CFR part 820 in accordance with 21 CFR 4.4(a)(1), 4.4(b)(1), or 4.4(b)(2). For further information, see the CGTP Guidance. FDA understands the complexity of manufacturing considerations and duties for combination products that contain an HCT/P. Accordingly, the Agency encourage manufacturers to contact the lead center for their product or OCP, as needed, with questions about how to comply with CGMP requirements for their particular product. V. Application of CGMP requirements to specific types of combination products The hypothetical scenarios addressed in this section focus on three types of combination products. While each of these types of combination products is subject both to the drug CGMPs and to the device QS regulation, each example is used to focus on particular CGMP considerations relating to CGMP provisions specified in 21 CFR 4.4(b). Specifically: • Section A, a prefilled syringe example, focuses on how to comply with the device QS regulation provisions specified in 21 CFR 4.4(b)(1) if a manufacturer adopts a drug CGMP-based streamlined approach for its CGMP operating system. • Section B, a drug-coated mesh example, focuses on considerations for complying with certain device QS regulations after a drug constituent part is combined with a device. • Section C, a drug-eluting stent (DES) example, focuses on how to comply with the drug CGMP provisions specified in 21 CFR 4.4(b)(2) if a manufacturer adopts a device QS regulation-based streamlined approach for its CGMP operating system. This discussion is intended to highlight only certain issues that a combination product might raise relating to the CGMP provisions specified in 21 CFR 4.4(b), and considerations for addressing these issues. The discussion may be helpful to inform understanding of the CGMP provisions that are addressed here not only in regard to the types of combination products in the scenarios, but for other types of combination products as well. However, this discussion is not intended to reflect a complete analysis of the CGMP issues that need to be addressed for the types of products discussed in the scenarios or other types of combination products. In addition, specific products may raise distinct issues that are not taken into account in the hypothetical scenarios presented below. If manufacturers have specific questions relating to their particular Contains Nonbinding Recommendations products, the Agency recommends that they contact the lead center for the product or OCP, as needed, for assistance. A. Prefilled syringe 1. Scenario Description A drug manufacturer (Manufacturer A) plans to sell a drug in a prefilled syringe presentation.114 Manufacturer A already has marketing approval for the drug product and intends to apply for marketing approval for the prefilled syringe presentation. No changes to the drug formulation will be made. Manufacturer A will buy off-the-shelf syringe components from a supplier (Manufacturer B) who also manufactures finished syringes using the same components. Manufacturer A will assemble the syringe components, prefill the syringe at a facility it operates, and then package, label, and distribute the prefilled syringe from this facility. Manufacturer A’s facility has an existing drug CGMP operating system. As the prefilled syringe is a single-entity combination product under 21 CFR 3.2(e)(1), Manufacturer A must demonstrate compliance with both the drug CGMPs and device QS regulation.115 To do so, Manufacturer A opts to establish a CGMP operating system using the drug CGMP-based streamlined approach in accordance with 21 CFR 4.4(b)(1). While Manufacturer A must ensure that its operating system fully complies with the drug CGMPs for this product, taking into account all of the issues raised by inclusion of the device constituent part, this example focuses on considerations for demonstrating compliance with the provisions from the device QS regulation specified in 21 CFR 4.4(b)(1). 2. Compliance with device QS regulation requirements Having chosen to use the drug CGMP-based streamlined approach under 21 CFR 4.4(b)(1), in addition to demonstrating compliance with the drug CGMPs, Manufacturer A must comply with the provisions of the device Quality System (QS) regulation specified in 21 CFR 4.4(b)(1). For each such provision, this discussion offers exemplary considerations and activities for the combination product manufacturer seeking to meet the device QS regulation requirements. a) 21 CFR 820.20, Management Responsibility While section 501 of the FD&C Act (21 U.S.C. 351) and 21 CFR 211.22, 211.25, and 211.180 establish requirements relevant to management responsibility, Manufacturer A must ensure that its CGMP operating system demonstrates compliance with the specific requirements in 21 CFR 820.20 (discussed in greater detail in section IV.A.1). 116 114 The design control considerations for a prefilled syringe with a biological product are largely similar to those covered in the example, although some additional issues may be more common such as the interaction of the biological product with the syringe materials and the effect of product viscosity on delivery. 115 See 21 CFR part 4. 116 See 21 CFR 4.4(b)(1). Contains Nonbinding Recommendations Manufacturer A should, for example, review its existing CGMP operating system to assess whether changes are needed to comply with this provision. As part of this review, management with executive responsibility for Manufacturer A should review the facility’s quality policy and develop and implement appropriate oversight procedures, if such procedures are not already in place, to ensure that both the policy and oversight are adequate. The oversight procedures should include clear delineation of the personnel to whom management with executive responsibility is delegating responsibility for implementing the quality policy (including translation into methods and procedures) and the CGMP operating system for this product at the facility. b) 21 CFR 820.30, Design Controls Manufacturer A is responsible for establishing and maintaining procedures for design control activities for the combination product. In this scenario, Manufacturer A is the owner and is manufacturing the prefilled syringe. Accordingly, Manufacturer A is responsible for the design control activities for the syringe as part of the combination product, as well as having overall responsibility for the combination product. However, Manufacturer A is buying the syringe components from Manufacturer B, another manufacturer, which uses the same components to manufacture finished syringes. As a result, Manufacturer A may be able to leverage syringe-specific design control documentation from the design controls Manufacturer B uses for its finished syringes.117 Because no changes are to be made to the drug other than being put into the syringe, the drug comes into the design control process as an input to the design of the syringe to ensure that the syringe’s design reflects adequate consideration of the drug’s characteristics, as indicated below. An appropriate first step for Manufacturer A would be to review Manufacturer B’s design control data to determine what new questions are raised by the use of the syringe with the drug, and to assess what additional design control activities may be needed as a consequence. It may be the case, for example, that Manufacturer A can demonstrate that the only new design questions that are raised concern the performance of the syringe as a container/closure to store the drug and the extent to which the contact between the syringe and the drug may affect its performance as a delivery system. Regardless, Manufacturer A must ensure that all design considerations for the combination product are addressed in accordance with 21 CFR 820.30. 117 If the supplier of the device components did not have design control information, Manufacturer A would likely need to undertake more extensive design control activities for the syringe. For example, Manufacturer A would need to perform device-specific verification testing to confirm that the syringe meets necessary specifications for plunger force or other parameters if the syringe component supplier has not conducted such testing suitable to enable leveraging. Contains Nonbinding Recommendations i. Design inputs and outputs The table below includes illustrative examples of design inputs and user needs and related design outputs for this prefilled syringe. Design Input/User Needs Required minimum/maximum dose delivery for drug Drug viscosity and desired/required delivery rate Expected use condition (e.g., expected user experience/education level) Maximum and minimum allowable temperature for prefilled syringe No degradation of drug or syringe over the expected shelf-life as a result of contact with one another Expected shipping method and appropriate storage conditions Drug delivery method (e.g., needle or needleless delivery) Design Output Drawing/specification for syringe dimensions, markings, etc. Drawing/specification for needle bore, glide force, etc. Content and reading level for the prefilled syringe’s labeling Packaging/labeling specifications for the prefilled syringe Specifications for drug-contacting syringe materials Design drawings/specifications for primary and secondary packaging, labeling for acceptable storage conditions Drawing/specification for needle and/or other associated syringe components ii. Design verification and validation Once Manufacturer A has established design outputs for all design inputs, it must perform design verification and validation activities to ensure that the combination product meets design input requirements, including user needs and intended uses.118 Examples of appropriate testing of the prefilled syringe include: bench testing of the delivery of the drug from the syringe to ensure repeatable and accurate drug delivery; shock and vibration testing of the packaged prefilled syringe to ensure no damage or loss of integrity in shipping; validation that expected users can adequately follow the instructions for use; other human factors studies; biocompatibility testing; 119 drug and syringe compatibility studies; leachables and extractables testing; and verification that the prefilled syringe works with all expected delivery methods (i.e., needle, needleless). These activities would be documented in the DHF pursuant to 21 CFR 820.30(j) and would be subject to design change and review requirements pursuant to 21 CFR 820.30(e) and (i). 118 See 21 CFR 820.30(f) and (g). 119 For additional information on biocompatibility, see Guidance for Industry and FDA Staff: Use of International Standard ISO 10993-1, "Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process" (June 2016). See also, USP Chapter <87> Biological Reactivity, In Vitro and USP <88> Biological Reactivity Tests, In Vivo. Contains Nonbinding Recommendations iii. Risk Analysis Manufacturer A should identify risks associated with the prefilled syringe design, its manufacturing processes, and intended uses, and also reduce or mitigate any unacceptable risk(s).120 The table below lists some potential risks associated with prefilled syringes and potential mitigations for these risks. Risk Syringe filled with incorrect drug dose Loss of sterility Drug contamination from materials of syringe construction Syringe failure during use Mitigation In-process acceptance testing, process validation Container-closure integrity testing, packaging validation/testing Purchasing controls (including receiving acceptance activities for components received from syringe component manufacturer), in-process and finished product testing to ensure no introduction of contaminants during manufacture and over the product shelf-life Design verification testing on syringe, purchasing controls over syringe component manufacturer(s) iv. Design changes Manufacturer A must also have procedures in place to ensure that any changes to design requirements are identified, documented, validated and/or verified, reviewed, and approved prior to implementation.121 Activities should include review of the original risk analysis, review and approval of the revised design inputs and outputs, and review and approval of the design change. For example, before changing a material used in the syringe that comes into contact with the drug, Manufacturer A should conduct verification activities to ensure that no degradation of performance characteristics will occur before the expiration date for the combination product as a result of the change of materials.122 Likewise, any change to the formulation of the drug should include design control activities such as verification to confirm that the new formulation does not degrade performance of the syringe. All of this information would need to become a part of the DHF.123 v. Design history file The DHF may include references or point to information residing elsewhere so long as the reference or pointer is precise enough to allow the necessary information to be readily 120 See 21 CFR 820.30(g). 121 See 21 CFR 820.30(i). 122 Changes to materials that contact the drug may raise drug CGMP considerations, for example, under stability testing and expiration dating requirements (21 CFR 211.137 and 21 CFR 211.167). When possible, manufacturers may leverage data collected in meeting these 21 CFR 211 requirements when determining what verification activities are required under 21 CFR 820.30. 123 See 21 CFR 820.30(j). Contains Nonbinding Recommendations accessed as needed, including for inspections. For example, elements of the syringe component manufacturer’s design documentation may be relied upon to support the combination product DHF. Such information on the syringe may reside at Manufacturer B’s (syringe component manufacturer) facility, so long as the necessary documentation can be accessed in a reasonable time during inspection of Manufacturer A. Manufacturer A should ensure access to such documentation through supplier agreements with Manufacturer B under its purchasing controls (21 CFR 820.50). Documentation of development of the drug product that preceded the design effort to incorporate the drug product into a prefilled syringe may be referenced in the DHF and become an input to the combination product design effort (though such drug-only development is not itself subject to design controls). c) 21 CFR 820.50, Purchasing Controls Manufacturer A is required to control its purchasing activities, including for the syringe components, in accordance with 21 CFR 820.50.124 For example, if the syringe barrel and plunger material is critical to ensuring that there is no adverse reaction with the drug, Manufacturer A should structure purchasing agreements with Manufacturer B to ensure that Manufacturer A is notified of any changes to this material prior to implementation of the change. Similarly, if Manufacturer A uses an outside facility for terminal sterilization of the prefilled syringe, Manufacturer A must also have appropriate controls over that sterilization service provider.125 d) 21 CFR 820.100, Corrective and Preventive Actions Manufacturer A is required to establish and maintain CAPA procedures for the combination product. Following are two examples of issues that might arise and exemplary steps for addressing them: Example 1: Manufacturer A has implemented in-process manufacturing verification procedures to confirm that the syringe is being filled with the correct amount of the drug, and the data from this verification are analyzed for potential nonconformities. Manufacturer A notes an increase in nonconformities relating to the volume of drug being put in the syringe and in turn opens a CAPA to investigate the problem. Upon investigation of the cause of the improper fill volume, Manufacturer A determines that maintenance procedures on the filling equipment are the cause of the incorrect fill volume. Manufacturer A updates the maintenance procedures and performs verification/validation testing to confirm that the changes correct the problem and do not cause new ones. Example 2: Manufacturer A begins receiving an increased number of customer complaints related to holes or other damage to the syringe’s sterile package and opens a CAPA to investigate the issue. The CAPA reveals that Manufacturer B has made changes to a syringe component such that there are sharp edges that can damage the sterile pouch during shipping. 124 In addition, because the device constituent part (syringe) is also a container/closure for the drug, Manufacturer A must perform acceptance testing of the syringe components in accordance with 21 CFR 211.84. 125 See 21 CFR 820.50. Contains Nonbinding Recommendations Manufacturer A works with Manufacturer B to eliminate the sharp edge or finds a new supplier. Manufacturer A also augments purchasing specifications and acceptance test steps to perform visual inspection of the syringe components. Manufacturer A repeats related design verification testing to ensure that the new syringe meets all design requirements and does not result in pouch damage during shipping. e) 21 CFR 820.170, Installation and 820.200, Servicing Installation and servicing requirements would not apply to the prefilled syringe because the product does not require installation or servicing activities. B. Drug-coated mesh 1. Scenario Description Manufacturer A plans to sell a synthetic surgical mesh coated with a drug. Manufacturer A has a marketing authorization to sell the uncoated mesh. Manufacturer A wants to coat the mesh with a drug to treat infection at the site of the product’s implantation. Manufacturer B has an approval to market a drug for local administration to treat infection at the site of implantation of this class of device, but not in a formulation suitable for coating onto the mesh. Manufacturer A has established a business relationship with Manufacturer B to use the drug and develop the data needed to support Manufacturer A’s marketing authorization for the coated mesh. Manufacturer B will manufacture the drug formulation for spraying onto the mesh, and Manufacturer A will manufacture the finished drug-coated mesh combination product. 2. Compliance with QS regulation requirements The coated mesh product is a single-entity combination product under 21 CFR 3.2(e)(1). Therefore, Manufacturer A is subject both to the drug CGMPs and the device QS regulation for this combination product. Accordingly, Manufacturer A must ensure that its CGMP operating system complies with both the device QS regulation and drug CGMPs, in accordance with one of the approaches permitted under 21 CFR 4.4. Because Manufacturer A is already marketing the uncoated mesh, it has an existing device QS regulation-based operating system, and chooses to operate under a device QS regulation-based streamlined approach for the combination product. This discussion focuses on design control and purchasing control considerations arising from inclusion of the drug constituent part in the combination product. a) 21 CFR 820.30, Design Controls A focus of the design control process for the drug constituent part of the combination product is to ensure that the drug-coated mesh will be safe and effective for treating infection at the site of implantation. Accordingly, if the necessary dose of the drug for effective treatment of infection, for example, is already known, it would be an input (if the precise dose is not yet known, then an input would be that the product elute a safe and effective dose); design outputs Contains Nonbinding Recommendations and validation and verification would need to be established to ensure that the required dose is provided when the drug elutes from the mesh.126 In addition, risk analysis must be conducted to identify any risks associated with the design, manufacturing, and use of the mesh.127 Mitigation measures should then be identified and performed to address any identified risks. Design reviews should cover these and other related design considerations for the product, and personnel with expertise in both the drug- and device-specific issues (as well as an individual independent from the design stage being reviewed) should be included in these reviews. The transfer of the product design into production specifications should address all important aspects of the drug constituent part for use in the combination product.128 i. Design inputs and outputs The table below includes illustrative examples of design inputs, including user needs, and corresponding design outputs relating to the inclusion of the drug constituent part. Design Input/User Needs Required delivery dose and delivery rate for the drug Expected use condition (e.g., anatomical location of use, surgical technique) Maximum allowable temperature during transportation, handling, and storage for the combination product No unacceptable degradation of the drug over the expected shelf-life No degradation of the surgical mesh over the expected shelf-life Design Output Drug formulation and concentration, coating thickness, uniformity of coating, manufacturing process requirements, allowable storage conditions Labeling (instructions for use), material/drug composition to ensure no damage to mesh or coating during surgical placement Packaging/labeling specifications for the combination product Specifications for the drug formulation drug- contacting materials and packaging, shelf-life labeling Specifications for mesh material, drug formulation and packaging, shelf-life labeling ii. Design verification and validation Several examples of design verification and validation activities are described below: - One intended use is that the drug-coated mesh will treat infections. Manufacturer A must develop adequate clinical data (design validation) to ensure that the drug, when combined with the mesh, is effective in treating infection and does not raise safety concerns.129 Design outputs from this study would include the drug concentration in the coating formulation (to be specified in purchasing controls over Manufacturer B) 126 See 21 CFR 820.30(d), (f), and (g). 127 See 21 CFR 820.30(g). 128 See 21 CFR 820.30(h). 129 See 21 CFR 820.30(g). Contains Nonbinding Recommendations and the coating thickness (specified in process controls over the application of the coating by Manufacturer A). − A user need is that a physician be able to use the mesh product as labeled without damaging the drug coating or the mesh material. Manufacturer A would have to verify that the mechanical properties of the coated mesh are such that the product can withstand the stresses anticipated during the surgical procedure and still perform as intended.130 The results would be used to define and develop design outputs for the combination product, including in-process acceptance testing criteria during manufacturing, appropriate product specifications for the drug coated mesh, and instructions for use. − Another input to the design process is that the product have a shelf-life consistent with the stability of the drug formulation and the mesh. Manufacturer A would perform design verification testing such as bench testing after aging to confirm that the critical performance properties of the mesh material are not degraded during storage or as a result of contact with the drug coating, as well as stability studies131 to ensure that the properties of the drug are not degraded over the expected shelf life. The design outputs arising from this process would include the labeled expiration date and storage conditions for the combination product and packaging design specifications. iii. Risk analysis and mitigation The table below lists some potential risks associated with a surgical mesh coated with a drug, and potential mitigations for these risks. Risk Drug concentration in coating not sufficient to treat infection (e.g., due to insufficient drug coating per surface area of the mesh or non-uniformity of coating), inappropriate delivery rate Mesh erodes or drug degrades during use or storage Mitigation Clinical testing of the combination product, in- process acceptance testing, manufacturing process validation Design verification testing (bench), clinical testing, labeling (instructions for use, expiration dating), purchasing controls over drug supplier, specifications and other process controls iv. Design history file All of the design control activities required by 21 CFR 820.30 (summarized in IV.A.2 above) must be addressed in the DHF for the drug-coated mesh. The information developed as a 130 See 21 CFR 820.30(f). 131 See the Guidance for Industry on Q1A(R2) Stability Testing of New Drug Substances and Products (November 2003). Contains Nonbinding Recommendations result of design control activities will be assessed as part of premarket review of this combination product (e.g., the suitability of the drug formulation and the compatibility of the mesh with the drug). Accordingly, much of the information included in the DHF would be submitted as part of the premarket review process. Manufacturer A may opt to incorporate such information into the DHF by cross-reference to such premarket documentation. Whatever approach Manufacturer A selects must ensure that all required design history information is readily available to FDA for review. The DHF for the surgical mesh must include design input, output, verification and validation data, and the results of design reviews for the combination product. In developing the design controls related to the drug constituent part, Manufacturer A may rely on the safety, efficacy, quality and in situ dose data for the drug as independently marketed. These existing data that supported approval of the drug would be available as a reference for the combination product DHF to enable development of design inputs for the drug constituent part and the combination product as a whole, and thus facilitate its development process. b) 21 CFR 820.50, Purchasing Controls Manufacturer A already has established procedures for controlling purchasing/supplier activities pursuant to 21 CFR 820.50. Under this provision, Manufacturer A must ensure that appropriate purchasing controls for Manufacturer B are established and maintained. In particular, based on risk associated with the drug and supplier, Manufacturer A must evaluate Manufacturer B as a potential supplier of the drug and establish the type and extent of control to be exercised over Manufacturer B as a selected supplier.132 Purchasing controls (and acceptance activities under 21 CFR 211.84) with respect to the drug constituent part should focus on ensuring that Manufacturer B can supply the drug that meets the specifications that Manufacturer A has established during the design control process. Manufacturer A should establish purchasing agreements with Manufacturer B to ensure that Manufacturer A is notified of any changes that may affect the performance of the combination product prior to Manufacturer B’s implementation of the changes. The notifications should address issues including changes in the drug specification, its components, composition of drug coating materials, or the drug manufacturing process or facility. Such proposed changes may require that Manufacturer A complete additional design verification and/or validation. For example, verification testing may be necessary to confirm that the purity and stability of the drug is maintained, pursuant to the requirements of 21 CFR 820.30(i). C. Drug Eluting Stent (DES) 1. Scenario Description In this scenario, Manufacturer A is the owner for a drug-eluting stent (DES) composed of a stent coated with a drug. Manufacturer B manufactures the active pharmaceutical ingredient 132 See 21 CFR 820.50(a)(2). Contains Nonbinding Recommendations (API or bulk drug substance), Manufacturer C manufactures a polymer with which the bulk drug substance will be combined for coating onto the stent, and Manufacturer D manufactures the materials used for the product’s primary packaging. Manufacturer A purchases the bulk drug substance from Manufacturer B and the polymer from Manufacturer C, then formulates the drug coating solution and uses it to coat the stent in its own facility. At the same facility, Manufacturer A packages the DES using the primary packaging materials it purchases from Manufacturer D. 2. Compliance with drug CGMP requirements The DES is a single-entity combination product as defined in 21 CFR 3.2(e)(1) and, therefore, is subject to both the drug CGMPs and device QS regulation. As a device manufacturer, Manufacturer A already has a CGMP operating system designed to comply with the device QS regulation and has elected to establish a device QS regulation-based streamlined approach for the DES in accordance with 21 CFR 4.4(b)(2). While Manufacturer A must ensure that this operating system complies with the device QS regulation, taking into account all of the issues raised by inclusion of the drug constituent part, this example focuses on considerations for complying with the drug CGMP provisions specified in 21 CFR 4.4(b)(2). a) 21 CFR 211.84, Testing and approval or rejection of drug components, product containers, and closures Manufacturer A has controls in place to evaluate suppliers, contractors, and consultants based on their ability to meet quality and other specified requirements and to control incoming materials in accordance with 21 CFR 820.50 and 21 CFR 820.80. Under 21 CFR 4.4(b)(2), Manufacturer A must augment its existing CGMP operating system as needed to satisfy the requirements of 21 CFR 211.84 for the DES. Manufacturer A’s purchasing controls for the DES must include evaluation of Manufacturer B as the supplier of the bulk drug substance, Manufacturer C as the supplier of the polymer for the coating, and Manufacturer D as the supplier of the primary packaging materials, in conformance with 21 CFR 820.50(a)(1). In addition, under its CGMP operating system for the facility, Manufacturer A has controls to identify the acceptance status of manufactured products. Manufacturer A’s responsibilities under 21 CFR 211.84 relate to these various obligations and controls arising from the device QS regulation. In accordance with 21 CFR 211.84, the bulk drug substance, polymer, and primary packaging materials supplied by manufacturers B, C, and D must be sampled, tested, or examined, as appropriate, by Manufacturer A to determine whether they should be approved or rejected for use. The primary packaging materials should be visually inspected to ensure that the correct, specified materials are received from Manufacturer D. Each lot of bulk drug substance and polymer must be tested to verify conformity with written specifications for purity, quality, and strength.133 Due to the nature and intended use of sterile drug eluting stents, testing must include microbiological testing of the bulk drug substance and polymer. 133 See 21 CFR 211.84(d)(2). Contains Nonbinding Recommendations Under certain circumstances, Manufacturer A may rely on a report of analysis from a supplier in lieu of conducting some of its own testing. If, for example, Manufacturer B performs conformity testing for the bulk drug substance (testing to ensure that the material meets appropriate purity, strength, and quality specifications) just prior to the shipment of material to Manufacturer A, then a report of analysis may be accepted by Manufacturer A in lieu of testing for these characteristics by Manufacturer A, if the following conditions are met.134 Manufacturer A is still responsible for the performance of at least one specific identity test upon receipt of each lot of the bulk drug substance, even when a report of analysis accompanies the lot.135 Reliance on reports of analyses is also contingent on Manufacturer A establishing the reliability of the supplier’s analyses through appropriate validation of the test results at appropriate intervals.136 The supplier can be evaluated through initial purchasing controls and subsequently at suitable intervals. A similar analysis would apply if Manufacturer C were to conduct conformity testing for the polymer it supplies to Manufacturer A. Incoming examination or testing by Manufacturer A and receipt of any reports of analysis must occur prior to use of the material in the manufacture of the DES. b) 21 CFR 211.103, Calculation of yield Calculation of yield should be conducted during all appropriate steps in the manufacturing process prior to and after application of the coating to the stent, including the formulation of the coating.137 Manufacturer A is responsible for the calculation of yield at appropriate phases of manufacture at its facility, including application of the coating to the DES, and the packaging of the DES. The formula used and the data generated for the calculation should be maintained in Manufacturer A’s batch production and control record. c) 21 CFR 211.132, Tamper-evident packaging requirements for over-the-counter (OTC) human drug products This regulatory requirement is not applicable to drug-eluting stents, as they are not OTC products. d) 21 CFR 211.137, Expiration dating As the manufacturer of the combination product, Manufacturer A is responsible for establishing the expiration date on the labeling of the finished combination product. The expiration date must be established based on the data from the stability studies for the finished packaged DES and should also take into account other shelf-life considerations as required under 134 See 21 CFR 211.84(d)(2). 135 21 CFR 211.84(d)(2). 136 See 21 CFR 211.84(d)(2). 137 Drug-coated stents that are rejected due only to defects in the device constituent part (stent) will result in corresponding loss of drug constituent part from the batch/lot. This loss should be captured as part of the yield calculations for the drug constituent part and investigation of the cause of that loss should identify the manufacturing problem that is leading to these device constituent part nonconformities. Contains Nonbinding Recommendations design control. These considerations include the functionality of the stent and polymer and the integrity of the coating and the packaging.138 e) 21 CFR 211.165, Testing and release for distribution Manufacturer A must test each batch of the finished combination product to determine conformance with the final written specifications for the product.139 A detailed listing of all the tests performed on the DES and the acceptance criteria should be incorporated into the documentation for the manufacturing, production, and laboratory systems. A description of each analytical test should be prepared and documented in standard operating procedures. A general list of tests for drug-eluting stents is provided below: Identification Impurities and Degradation Products • Appearance • • Assay • • Content Uniformity • Drug Release Rate (immediate and/or extended release rates) • Package Integrity and Sterility Assurance • Endotoxins • Particulate Matter • Additional Testing, when applicable (including testing for polymer molecular weight, residual monomers, catalysts, and other additives) f) 21 CFR 211.166, Stability testing Stability testing for the final DES product should address the following considerations: appearance, assay/drug content, impurities/degradation products, rate of drug release, particulate matter, sterility, and package integrity. Methods used for batch release under 21 CFR 211.165 may also be suitable for stability testing. Analytical procedures for stability testing should be fully validated as suitable to demonstrate stability.140 g) 21 CFR 211.167, Special testing requirements Manufacturer A must conduct or contract to conduct testing of the DES in accordance with 21 CFR 211.167(a) because this class of product is purported to be sterile and non- pyrogenic. In addition, testing in accordance with 21 CFR 211.167(c) must be conducted because the DES constitutes a controlled-release dosage form. 138 See 21 CFR 211.137(a) and (b). 139 See 21 CFR 211.165(a). 140 If Manufacturer A decides to develop a family of drug-eluting stents over time, differing from one another in the size of the stent, the Agency does not intend to object to the manufacturer’s leveraging previously generated stability data for the existing versions to establish expiration dating for later versions, or newer products being incorporated into the ongoing stability program for the existing marketed drug-eluting stents, so long as the manufacturer can provide adequate justification and such approaches have been reviewed by FDA, where applicable. Contains Nonbinding Recommendations h) 21 CFR 211.170, Reserve samples Manufacturer A must maintain reserve samples representative of each lot of the active ingredient used in the combination product and of each lot or batch of the finished, packaged DES.141 Reserve samples must consist of at least twice the quantity necessary to perform all tests required for the active ingredient and the finished DES, excluding sterility and pyrogen testing.142 The reserve samples must be kept for the time periods required by 21 CFR 211.170. The samples of the active ingredient must be kept for 1 year past the expiration date of the last lot of finished drug-eluting stents to use that lot of the active ingredient.143 The samples for each lot or batch of the finished DES must be kept for 1 year after the expiration date for the combination product.144 If Manufacturer A maintains reserve samples in a third-party storage facility, Manufacturer A should ensure, via purchasing controls (21 CFR 820.50), that the facility can meet applicable CGMP requirements.145 VI. Contact Us If you have questions regarding compliance with CGMP requirements for combination products after reviewing this guidance and the materials cited in this document, we encourage you to contact us. We recommend you contact the lead center for your product in the first instance. However, you may also contact OCP for assistance. Below are contact points for each center and OCP. You may follow existing processes for your lead center when requesting feedback on combination product issues (e.g., meeting requests to CBER/CDER,146 pre- submissions to CDRH147). 1. CBER Mail: Phone: Email: Office of Communication, Outreach and Development (OCOD) 10903 New Hampshire Avenue Building 71, Room 3128 Silver Spring, MD 20993 1-800-835-4709 or 240-402-8010 ocod@fda.hhs.gov 141 See 21 CFR 211.170(a) and (b). 142 See 21 CFR 211.170(a) and (b). 143 See 21 CFR 211.170(a)(1). 144 See 21 CFR 211.170(b)(1). 145 Additional information on drug-eluting stents is provided in the draft Guidance for Industry on Coronary Drug- Eluting Stents–Nonclinical and Clinical Studies –(March 2008). When finalized, this guidance will represent FDA’s current thinking on this topic. 146 See Guidance for Industry: Formal Meetings Between the FDA and Sponsors or Applicants (May 2009). 147 See Guidance for Industry and FDA Staff: Requests for Feedback on Medical Device Submissions: The Pre-Submission Program and Meetings with Food and Drug Administration Staff (February 2014). 2. CDER Mail: Phone: Email: 3. CDRH Mail: Contains Nonbinding Recommendations Division of Drug Information (DDI) Hillandale Building 10001 New Hampshire Avenue Silver Spring, MD 20993 1-855-543-3784 or 301-796-3400 druginfo@fda.hhs.gov Division of Industry and Consumer Education (DICE) 10903 New Hampshire Avenue Building 66, Room 4621 Silver Spring, MD 20993 Phone: 1-800-638-2041 or 301-796-7100 Email: DICE@fda.hhs.gov 4. OCP Mail: Office of Combination Products Food and Drug Administration 10903 New Hampshire Avenue Building 32, Hub/Mail Room #5129 Silver Spring, MD 20993 301-796-8930 301-847-8619 combination@fda.gov Phone: Fax: Email: VII. Glossary Note: this glossary is for use exclusively with this guidance document. Definitions that have been taken from federal regulations include the relevant citation. Constituent part: A drug, device, or biological product that is part of a combination product. (21 CFR 4.2) Co-packaged combination product: Two or more separate products packaged together in a single package or as a unit and comprised of drug and device products, device and biological products, or biological and drug products. (21 CFR 3.2(e)(2)) Cross-labeled combination product: (i) A drug, device, or biological product packaged separately that according to its investigational plan or proposed labeling is intended for use only with an approved individually specified drug, device, or biological product where both are required to achieve the intended use, indication, or effect and where upon approval of the proposed product the labeling of the approved product would need to be changed, e.g., to reflect Contains Nonbinding Recommendations a change in intended use, dosage form, strength, route of administration, or significant change in dose; or (ii) any investigational drug, device, or biological product packaged separately that according to its proposed labeling is for use only with another individually specified investigational drug, device, or biological product where both are required to achieve the intended use, indication, or effect. (21 CFR 3.2(e)(3) and 21 CFR 3.2(e)(4)) Device QS regulation-based streamlined approach: A CGMP operating system that is intended to demonstrate compliance with all of the provisions of the device QS regulation and the following provisions from the drug CGMPs in accordance with 21 CFR 4.4(b)(2): (i) 21 CFR 211.84 (ii) 21 CFR 211.103 (iii) 21 CFR 211.132 (iv) 21 CFR 211.137 (v) 21 CFR 211.165 (vi) 21 CFR 211.166 (vii) 21 CFR 211.167 (viii) 21 CFR 211.170 Testing and approval or rejection of components, drug product containers, and closures Calculation of yield Tamper-evident packaging requirements for over-the- counter (OTC) human drug products Expiration dating Testing and release for distribution Stability testing Special testing requirements Reserve samples Drug CGMPs: The current good manufacturing practice regulations set forth in 21 CFR 210 and 21 CFR part 211. (21 CFR 4.2) Drug CGMP-based streamlined approach: A CGMP operating system that is intended to demonstrate compliance with all of the provisions from the drug CGMPs and the following provisions from the device QS regulation in accordance with 21 CFR 4.4(b)(1): (i) 21 CFR 820.20 (ii) 21 CFR 820.30 (iii) 21 CFR 820.50 (iv) 21 CFR 820.100 (v) 21 CFR 820.170 (vi) 21 CFR 820.200 Management responsibility Design controls Purchasing controls Corrective and preventive action Installation Servicing Lead center: The FDA center (CBER, CDER, or CDRH) that has primary jurisdiction for premarket review and regulation of a combination product. Manufacture: Includes, but is not limited to, designing, fabricating, assembling, filling, processing, testing, labeling, packaging, repackaging, holding, and storage. (21 CFR 4.2) CGMP operating system: The operating system within an establishment that is designed and implemented to address and meet the current good manufacturing practice requirements for a combination product. (21 CFR 4.2) Contains Nonbinding Recommendations Owner: For purposes of this guidance, the entity that holds the marketing authorization for a combination product (regardless of whether that entity is directly engaged in the manufacture of the product). Device QS regulation: The quality system regulation in 21 CFR part 820. (21 CFR 4.2) Single-entity combination product: A product comprised of two or more regulated components, i.e., drug/device, biologic/device, drug/biologic, or drug/device/biologic, that are physically, chemically, or otherwise combined or mixed and produced as a single entity. (21 CFR 3.2(e)(1)) Streamlined approach: Either of the two approaches permitted under 21 CFR part 4, which allows combination product manufacturers to demonstrate compliance with both the drug CGMPs and device QS regulation by designing and implementing a CGMP operating system that demonstrates compliance with part 211 or part 820 in its entirety plus specified provisions of the other set of regulations. VIII. References Device 1. Applying Human Factors and Usability Engineering to Medical Devices (http://www.fda.gov/downloads/MedicalDevices/.../UCM259760.pdf) (February 2016) 2. Design Control Guidance for Medical Device Manufacturers, Guidance for Industry (March 1997) (http://www.fda.gov/downloads/MedicalDevices/DeviceRegulationandGuidance/Guidanc eDocuments/ucm070642.pdf) 3. Glass Syringes for Delivering Drug and Biological Products: Technical Information to Supplement International Organization for Standardization (ISO) Standard 11040-4 - Draft Guidance for Industry and FDA Staff (April 2013) (http://www.fda.gov/downloads/RegulatoryInformation/Guidances/UCM346181.pdf) 4. Quality System Information for Certain Premarket Application Reviews, Guidance for Industry and FDA Staff (Feb. 3, 2003) (http://www.fda.gov/downloads/MedicalDevices/DeviceRegulationandGuidance/Guidanc eDocuments/ucm070899.pdf) 5. Requests for Feedback on Medical Device Submissions: The Pre-Submission Program and Meetings with Food and Drug Administration Staff, Guidance for Industry (February 2014) (http://www.fda.gov/downloads/medicaldevices/deviceregulationandguidance/guidanced ocuments/ucm311176.pdf) 6. Sterilized Convenience Kits for Clinical and Surgical Use, Guidance for Industry (Jan. 2002) Contains Nonbinding Recommendations (http://www.fda.gov/downloads/MedicalDevices/DeviceRegulationandGuidance/Guidanc eDocuments/ucm071029.pdf) 7. Use of International Standard ISO- 1 10993, "Biological Evaluation of 2 Medical Devices Part 1: Evaluation 3 and Testing", DRAFT Guidance for Industry (http://www.fda.gov/downloads/medicaldevices/deviceregulationandguidance/guidanced ocuments/ucm348890.pdf) Drugs 8. CGMP for Phase 1 Investigational Drugs, Guidance for Industry (July 2008) (http://www.fda.gov/downloads/Drugs/GuidanceComplianceRegulatoryInformation/Guid ances/UCM070273.pdf) 9. Container Closure Systems for Packaging Human Drugs and Biologics: Chemistry, Manufacturing, and Controls Documentation, Guidance for Industry, (May 1999) (http://www.fda.gov/downloads/Drugs/GuidanceComplianceRegulatoryInformation/Guid ances/UCM070551.pdf) 10. Contract Manufacturing Arrangement for Drugs: Quality Agreements, Guidance for Industry (November 2016) (http://www.fda.gov/downloads/drugs/guidancecomplianceregulatoryinformation/guidan ces/ucm353925.pdf) 11. Formal Meetings Between the FDA and Sponsor or Applicants, Guidance for Industry (March 2015) (http://www.fda.gov/downloads/drugs/guidancecomplianceregulatoryinformation/guidan ces/ucm437431.pdf) 12. Investigating Out-of-Specification (OOS) Test Results for Pharmaceutical Production, Guidance for Industry (Oct. 2006) (http://www.fda.gov/downloads/Drugs/GuidanceComplianceRegulatoryInformation/Guid ances/UCM070287.pdf) 13. Process Validation: General Principles and Practices, Guidance for Industry (Jan. 2011) (http://www.fda.gov/downloads/Drugs/GuidanceComplianceRegulatoryInformation/Guid ances/UCM070336.pdf) 14. Q1A(R2) Stability Testing of New Drug Substances and Products, Guidance for Industry (Nov. 2003) (http://www.fda.gov/downloads/Drugs/GuidanceComplianceRegulatoryInformation/Guid ances/UCM073369.pdf) 15. Q1B Photostability Testing of Drug Substances and Products, Guidance for Industry (November 1996) Contains Nonbinding Recommendations (http://www.fda.gov/downloads/drugs/guidancecomplianceregulatoryinformation/guidan ces/ucm073373.pdf) 16. Q1C Stability Testing for New Dosage Forms, Guidance for Industry (November 1996) (http://www.fda.gov/downloads/drugs/guidancecomplianceregulatoryinformation/guidan ces/ucm073374.pdf) 17. Q1D Bracketing and Matrixing Designs for Stability Testing of New Drug Substances and Products, Guidance for Industry (January 2003) (http://www.fda.gov/downloads/Drugs/.../Guidances/ucm073379.pdf) 18. Q1E Evaluation of Stability Data, Guidance for Industry (June 2004) (http://www.fda.gov/downloads/drugs/guidancecomplianceregulatoryinformation/guidan ces/ucm073380.pdf) 19. Q7A Good Manufacturing Practice Guidance for Active Pharmaceutical Ingredients, Guidance for Industry (Aug 2001) (http://www.fda.gov/ICECI/ComplianceManuals/CompliancePolicyGuidanceManual/uc m200364.htm) 20. Q8(R2) Pharmaceutical Development, Guidance for Industry (November 2009) (http://www.fda.gov/downloads/Drugs/.../Guidances/ucm073507.pdf) 21. Q9 Quality Risk Management, Guidance for Industry (June 2006) (http://www.fda.gov/downloads/Drugs/.../Guidances/ucm073511.pdf) 22. Q10 Pharmaceutical Quality System, Guidance for Industry (April 2009) (http://www.fda.gov/downloads/Drugs/GuidanceComplianceRegulatoryInformation/Guid ances/UCM073517.pdf) 23. Sterile Drug Products Produced by Aseptic Processing — Current Good Manufacturing Practice, Guidance for Industry (Sept. 2004) (http://www.fda.gov/downloads/Drugs/GuidanceComplianceRegulatoryInformation/Guid ances/UCM070342.pdf) 24. Submission of Documentation in Applications for Parametric Release of Human and Veterinary Drug Products Terminally Sterilized by Moist Heat Process, Guidance for Industry (February 2010) (http://www.fda.gov/downloads/drugs/guidancecomplianceregulatoryinformation/guidan ces/ucm437431.pdf) Biological Products 25. Cooperative Manufacturing Arrangements for Licensed Biologics, Guidance for Industry (Nov. 2008) (http://www.fda.gov/downloads/BiologicsBloodVaccines/GuidanceComplianceRegulator Contains Nonbinding Recommendations yInformation/Guidances/General/UCM069908.pdf) HCT/Ps 26. Current Good Tissue Practice (CGTP) and Additional Requirements for Manufacturers of Human Cells, Tissues, and Cellular and Tissue-Based Products (HCT/Ps), Guidance for Industry (Dec 2011) (http://www.fda.gov/downloads/BiologicsBloodVaccines/GuidanceComplianceRegulator yInformation/Guidances/Tissue/UCM285223.pdf) Combination Products 27. Coronary Drug-Eluting Stents – Nonclinical and Clinical Studies, Draft Guidance for Industry (March 2008) (http://www.fda.gov/downloads/Drugs/GuidanceComplianceRegulatoryInformation/Guid ances/UCM228704.pdf) 28. How to Write a Request for Designation (RFD), Guidance for Industry (April 2011) (http://www.fda.gov/RegulatoryInformation/Guidances/ucm126053.htm) 29. Human Factors Studies and Related Clinical Study Considerations in Combination Product Design and Development, Draft Guidance for Industry and FDA Staff (February 2016) (http://www.fda.gov/ucm/groups/fdagov-public/@fdagov- afdagen/documents/document/ucm484345.pdf) 30. Technical Considerations for Pen, Jet, and Related Injectors Intended for Use with Drugs and Biological Products, Guidance for Industry and FDA Staff (June 2013) (http://www.fda.gov/downloads/RegulatoryInformation/Guidances/UCM147095.pdf) General 31. Pyrogen and Endotoxins Testing: Questions and Answers, Guidance for Industry (June 2012) (http://www.fda.gov/downloads/Drugs/GuidanceComplianceRegulatoryInformation/Guid ances/UCM310098.pdf) --- ### Document: FDA ComboProd HF Complete (FDA) # FDA Draft Guidance: Human Factors Studies in Combination Product Design and Development (Feb 2016): Human Factors Studies and Related Clinical Study Considerations in Combination Product Design and Development Human Factors Studies and Related Clinical Study Considerations in Combination Product Design and Development Draft Guidance for Industry and FDA Staff This guidance document is for comment purposes only. Submit one set of either electronic or written comments on this draft guidance by the date provided in the Federal Register notice announcing the availability of the draft guidance. Submit electronic comments to http://www.regulations.gov. Submit written comments to the Division of Dockets Management (HFA-305), Food and Drug Administration, 5630 Fishers Lane, Rm. 1061, Rockville, MD 20852. You should identify all comments with the docket number listed in the notice of availability that publishes in the Federal Register. Additional copies of this guidance are available from the Office of Combination Products website at http://www.fda.gov/CombinationProducts/default.htm. For questions on the content of this guidance, contact the Office of Combination Products at combination@fda.gov or patricia.love@fda.hhs.gov. U.S. Department of Health and Human Services Food and Drug Administration Center for Devices and Radiological Health, Center for Drug Evaluation Research, Center for Biologics Evaluation and Research, and Office of Combination Products in the Office of the Commissioner February 2016 Contains Nonbinding Recommendations Table of Contents I. II. INTRODUCTION............................................................................................................. 2 BACKGROUND ............................................................................................................... 3 III. HUMAN FACTORS ......................................................................................................... 5 A. B. 1. 2. 3. C. D. E. 1. 2. Glossary and Concepts ......................................................................................... 5 Evaluation of Use-Related Risk ........................................................................... 6 Critical Tasks ........................................................................................................ 7 Intended Users and Use Environment ................................................................ 8 Training ................................................................................................................. 8 Human Factors-Formative Studies ..................................................................... 9 Human Factors Knowledge Task Studies ......................................................... 12 Human Factors Validation Studies ................................................................... 10 Human Factors-Simulated Use Validation Studies ......................................... 10 Human Factors-Actual Use Validation Studies ............................................... 10 IV. PROCESS CONSIDERATIONS ................................................................................... 12 A. B. C. Considerations on Whether to Submit Combination Product Human Factors Study Data ........................................................................................................... 12 Considerations for Design Changes After HF-Validation .............................. 14 Human Factors Information to Submit in a Combination Product Investigational Application ................................................................................ 14 D. Marketing Application Review of HF Studies and Certain Labeling ............ 15 V. RELATIONSHIP OF HUMAN FACTORS AND MAJOR CLINICAL STUDIES OF THE COMBINATION PRODUCT ........................................................................ 16 VI. HOW TO OBTAIN ADDITIONAL INFORMATION ............................................... 17 APPENDIX A: USER TASK FAILURE EXAMPLES ........................................................ 18 i Contains Nonbinding Recommendations Human Factors Studies and Related Clinical Study Considerations in Combination Product Design and Development1 Draft Guidance for Industry and FDA Staff This draft guidance, when finalized, will represent the current thinking of the Food and Drug Administration (FDA or Agency) on this topic. It does not establish any rights for any person and is not binding on FDA or the public. You can use an alternative approach if it satisfies the requirements of the applicable statutes and regulations. To discuss an alternative approach, contact the FDA staff responsible for this guidance as listed on the title page. I. INTRODUCTION AND SCOPE This document provides guidance to industry and FDA Staff on the underlying principles of human factors (HF) studies during the development of combination products as defined under 21 CFR Part 3. This guidance describes Agency recommendations regarding HF information in a combination product investigational or marketing application and clarifies the different types of HF studies; the recommended timing and sequencing of HF studies; and how HF studies are part of the process to maximize the likelihood that the combination product user interface is safe and effective for use by the intended users, uses, and environments. In addition, the guidance describes how HF studies relate to other clinical studies. The guidance also provides process considerations for HF information in investigational or marketing applications to promote development and timely review of safe and effective combination products. This guidance focuses on HF issues related to combination products that are comprised of a drug or biological product and a device (also referred to in this guidance as medical device) for review in an investigational or marketing application submitted to the Center for Biologics Evaluation and Research (CBER), the Center for Devices and Radiological Health (CDRH), or the Center for Drug Evaluation and Research (CDER). The application types include an investigational device exemption application (IDE), an investigational new drug application (IND), biologics license application (BLA), new drug application (NDA), or premarket approval application (PMA). However, the principles and recommendations may be applicable to combination products reviewed under other types of applications (e.g., premarket notification (510(k)) or abbreviated new drug application (ANDA)) as appropriate.2 1 This guidance has been prepared by the Office of Combination Products in the Office of Special Medical Programs in the Office of the Commissioner in association with the Center for Biologics Evaluation and Research, the Center for Drug Evaluation and Research, and the Center for Devices and Radiologic Health. 2 The applicability of HF studies for certain combination product design changes under the 510(k) or ANDA program are beyond the scope of this document. Applicants who are considering whether the combination product design change would change the center assignment should contact the Office of Combination Products (combination@fda.gov) for questions on the center assignment. For information on the application types within a center, contact the respective center jurisdiction officers at CDERproductjurisdiction@fda.hhs.gov , CDRHproductjurisction@fda.hhs.gov, or cberombusmana@fda.hhs.gov. Applicants preparing to submit a combination product for review under an ANDA that may include HF studies should contact the CDER Office of Contains Nonbinding Recommendations Related information is available in the Agency Guidance Applying Human Factors and Usability Engineering to Optimize Medical Device Design3 and the Agency Draft Guidance Safety Considerations for Product Design to Minimize Medication Errors.4 Additionally, this guidance supplements other existing guidance documents developed by CBER, CDRH, CDER, and the Office of Combination Products (OCP) that describe other aspects of product development. (See Section VI for a list of some additional guidance documents.) FDA’s guidance documents, including this guidance, do not establish legally enforceable responsibilities. Instead, guidances describe the FDA’s current thinking on a topic and should be viewed only as recommendations, unless specific regulatory or statutory requirements are cited. The use of the word should in FDA’s guidances means that something is suggested or recommended, but not required. II. BACKGROUND Combination products, as described in 21 CFR Part 3, are comprised of any combination of a drug and a device; a device and a biological product; a biological product and a drug; or a drug, a device, and a biological product.5 The constituent parts of a combination product retain their regulatory status (as a drug, device, or biological product) after they are combined. Accordingly, a combination product remains subject to the regulatory requirements associated with its constituent parts. receives requests to clarify how HF concepts apply to the development of a combination product when one of the constituent parts is a device. Inquiries include: • What types of HF studies might need to be conducted for the combination product? • When is the appropriate time to perform HF Validation studies? • What is the role of HF studies as compared to other types of clinical studies? • Are additional HF studies necessary when the design of the combination product changes? Other general inquiries relate to regulatory considerations for combination products such as when a HF study is subject to review and approval by an institutional review board (IRB),6 and how HF studies are considered in User Fee determinations.7 Generic Drugs at GenericDrugs@fda.hhs.gov regarding controlled correspondence subject to the Generic Drug User Fee Act (GDUFA) performance goals to discuss considerations related to HF studies. 3 Guidance for Industry and FDA Staff, Applying Human Factors and Usability Engineering to Optimize Medical Device Design, accessible at http://www.fda.gov/downloads/MedicalDevices/DeviceRegulationandGuidance/GuidanceDocuments/UCM259760. pdf. 4 Draft Guidance Safety Considerations for Product Design to Minimize Medication Errors, accessible at http://www.fda.gov/downloads/Drugs/GuidanceComplianceRegulatoryInformation/Guidances/UCM331810.pdf. FDA’s draft guidance documents represent FDA’s proposed approach on the topics. 5 For purposes of this document the term “drug” also refers to biological products unless otherwise indicated. 6 Clinical studies regulated under 21 CFR Part 312 (IND requirements) or Part 812 (IDE requirements) and clinical studies intended to support an investigational or marketing application are subject to applicable requirements under 21 CFR Parts 50 and 56. See 21 CFR 50.1(a), 50.20, 56.101(a), and 56.103. As used in this document, clinical Contains Nonbinding Recommendations For medical devices, the use of human factors and usability engineering (e.g., applying the knowledge of human behavior, abilities, and limitations to the design of a medical device) plays a key role in maximizing the likelihood that the device will be safe and effective for use by the intended users, for the intended uses, and for the intended use environments. Under the medical device design control requirements described in 21 CFR 820.30, design validation must include a risk analysis where appropriate. As part of the risk analysis, device manufacturers should identify and analyze potential use-related hazards, including lessons learned from reported errors with similar products, and as appropriate, incorporate and validate design features that mitigate or eliminate these hazards. This assessment informs the device design development to eliminate or minimize use errors that could cause harm or compromise medical treatment. For a drug product, goals for reducing use-related hazards are reflected in the process and data that support selection of the drug formulation, assurance of product quality,8 drug risk management activities,9 and in pharmaceutical quality system principles.10 Drug development should take into account the user interface and factors that can reduce the risk for medication errors; i.e., features to enhance patient safety. Such features include product appearance, identification markings (such as imprint codes on solid oral dosage forms), container closure, packaging configurations, labeling (including labels on containers and cartons), and nomenclature.11 The Prescription Drug User Fee Act IV (PDUFA IV)12 provides that one of the development goals is to ensure drug safety by prospectively designing a drug that minimizes the risk for errors made by intended end users.13 study has the same meaning as investigation or clinical investigation as defined in Parts 50, 56, 312, and 812, as applicable. 7 For information on user fee assessment under the Prescription Drug User Fee Act (PDUFA) for applications containing clinical studies, see FDA Guidance Submitting Separate Marketing Applications and Clinical Data for Purposes of Assessing User Fees accessible at http://www.fda.gov/downloads/Drugs/GuidanceComplianceRegulatoryInformation/Guidances/UCM079320.pdf. As described in that document the term “clinical data, for purposes of assessing user fees, encompasses a broad range of studies that are purported to be adequate and well-controlled investigations submitted in support of approval. This includes [1] study reports or literature of what are explicitly or implicitly represented by the applicant to be adequate and well-controlled trials for safety or effectiveness; or [2] reports of comparative activity (other than bioequivalence and bioavailability studies), immunogenicity, or efficacy, where those reports are necessary to support a claim of comparable clinical effect. As applicable, FDA will determine whether a HF study would meet these criteria. 8 See Guidance for Industry Q8(R2) Pharmaceutical Development accessible at http://www.fda.gov/downloads/drugs/guidancecomplianceregulatoryinformation/guidances/ucm073507.pdf 9See Guidance for Industry Q9 Quality Risk Management accessible at http://www.fda.gov/downloads/Drugs/GuidanceComplianceRegulatoryInformation/Guidances/UCM073511.pdf . 10 See Guidance for industry Q10 Pharmaceutical Quality System accessible at http://www.fda.gov/downloads/Drugs/GuidanceComplianceRegulatoryInformation/Guidances/UCM073517.pdf. 11 As defined in FD&C Act section 201(m), “labeling” means “all labels and other written, printed, or graphic matters (1) upon any article or any of its containers or wrappers, or (2) accompanying such article.” As defined in FD&C Act section 201(k), “label” means “a display of written, printed, or graphic matter upon the immediate container of any article.” 12 See information under Item-IX accessible at http://www.fda.gov/ForIndustry/UserFees/PrescriptionDrugUserFee/ucm119243.htm. 13 Measures for designing such a drug could address, among other things, concerns regarding: look-alike and sound- alike proprietary names; unclear label abbreviations, acronyms, and dose designations; and other label and packaging design that may lead to user error. Contains Nonbinding Recommendations For a combination product that includes drug and device constituent parts, both the device design control requirements and drug development expectations apply to the entire combination product.14 Therefore, when evaluating a combination product, the design of the product user interface should be assessed in HF studies if needed to ensure that use-related hazards associated with the product are eliminated or mitigated to reduce patient adverse events and medication errors attributable to use-related errors. This document focuses on human factors considerations for combination products to promote consistency in their design, development and review. III. HUMAN FACTORS A. Glossary and Concepts For purposes of this document, the following definitions and concepts apply to HF studies, the final finished combination product, and the major clinical study. For additional information on these terms see the sections that follow the glossary. For related definitions see Agency guidance Applying Human Factors and Usability Engineering to Optimize Medical Device Design.3 1. Human Factors Study (or HF Study): A study conducted with representative users to assess the adequacy of the combination product user interface design to eliminate or mitigate potential use-related hazards. Typically, HF studies are part of an iterative design process that is driven by the complexity of the combination product and the nature of the safety considerations. The HF study evaluates: (i) the ability of the user to perform critical tasks, and (ii) the ability of the user to understand the information in the packaging and labeling, such as product labels or instructions for use, that inform the user’s actions and that are critical to the safe and effective use of the combination product (e.g., product preparation, administration, maintenance and disposal, or what actions to take if an adverse reaction occurs). Both types of evaluations may be part of the HF Formative and HF Validation studies described below. a. HF Formative Study: A study conducted on a combination product prototype user interface at one or more stages during the iterative product development process to assess user interaction with the product and identify potential use errors. HF Formative studies are iterative and inform the need for user interface changes (e.g., product design or labeling changes) and inform the content of the HF Validation study. For additional information on HF Formative studies see Section III.C. HF Validation Study: A study conducted to demonstrate that the final finished combination product user interface can be used by intended users without serious use errors or problems, for the product’s intended uses and under the expected use conditions. The study should demonstrate that use-related hazards for the final finished combination product (see glossary item A.2 below) have been eliminated or that the mitigation for residual risks is acceptable; i.e., the benefit of product use 14 For combination products that include a device constituent part, design controls must be applied to the combination product. See 21 CFR 4.4; 78 FR 4307 (Jan. 27, 2013). Current Good Manufacturing Practice Requirements for Combination Products is accessible at https://www.federalregister.gov/articles/2013/01/22/2013- 01068/current-good-manufacturing-practice-requirements-for-combination-products. Contains Nonbinding Recommendations outweigh the residual risk of the product. The study participants are representative of the intended users and the study conditions are representative of expected use conditions. 2. Final Finished Combination Product: The final finished combination product is the product intended for market and submitted in the marketing application. This term applies to the combined final device, drug, and/or biological product configuration including all product user interfaces (e.g., proposed packaging, labels and labeling, including training programs). 3. Major Clinical Study (or Major Clinical Trial): As opposed to a HF study, a major clinical study is a larger scale clinical study that occurs during a later phase of combination product development. Major clinical studies provide the primary support for the safety and effectiveness of a product for a proposed indication (e.g., adequate and well-controlled studies15).16 In addition to adequate and well-controlled studies, other types of later phase larger scale clinical studies may also be considered major clinical studies; e.g., a long-term extension study. . B. Evaluation of Use-Related Risk Consistent with a risk-based design and development paradigm, the foundation for HF study designs, testing and evaluation should be a use-related risk analysis of a combination product. A use-related risk analysis is a crucial step to help identify use-related hazards associated with the combination product, as well as to characterize high-risk hazards so they can be mitigated or eliminated through improved product interface design. The use-related risk analysis will help identify critical tasks that should be evaluated in a HF study, inform the priority of testing the tasks in a HF study, and determine if there are specific use scenarios to include in testing. A variety of methods can be used to develop and analyze use-related hazards. Two methods frequently used are Failure Mode and Effects Analysis (FMEA) and Fault Tree Analysis (FTA).17 The use-related risk analysis should take into account: all the intended uses, users, and use environments; therapeutic or diagnostic procedures associated with the use of the combination product; similar products used within the environments; and any associated medical factors that may affect the safe use of the combination product. In addition, if previous models of the same or similar combination products exist, the risk analysis should incorporate information on known use-related problems with those products. This information can be obtained from the applicant’s own experience as well as from public sources such as literature, adverse event reports, and product safety communications. 15 See CFR 314.126. 16 The term Major Clinical Study is consistent with other terms such as “phase-3 clinical study,” “key clinical study,” and “pivotal studies or trials.” 17 For more information on FMEA, FTA and other risk analysis methods, see Guidance for Industry and FDA Staff, Applying Human Factors and Usability Engineering to Optimize Medical Device Design, accessible at http://www.fda.gov/downloads/MedicalDevices/DeviceRegulationsandGuidance/Guidancedocuments/UCM259760. pdf. Contains Nonbinding Recommendations 1. Critical Tasks The use-related risk analysis should identify critical tasks.18 Critical tasks are user tasks that, if performed incorrectly or not performed at all, would or could cause harm to the patient or user, where harm is defined to include compromised medical care. Thus, categorizing a task as critical is dependent on the unique considerations for each combination product. The Agency expects the risk analysis for the combination product to include an identification of all the critical tasks required for using the combination product, the consequences for failing to perform each critical task correctly, and the strategies that have been applied in the design of the user interface to eliminate or reduce risks to acceptable levels. Such an assessment should include considerations of the indication, the users, the environment and other conditions that might influence the importance of a particular task. Some examples of critical tasks to illustrate this concept include: • The patient being able to successfully self-administer a drug at the prescribed dose identified in the labeling. Failure to successfully perform this task could harm the patient due to mis-dosing, under-dosing, overdosing, or inability to deliver a dose. • The user being able to safely dispose of a used syringe. Failure to successfully perform this task could result in needle sticks. • The patient being able to appropriately navigate the user interface for a patient-controlled analgesia (PCA) delivery system. Failure to successfully perform this task could result in missed doses, inappropriate repeat doses, or overdoses. • The user being able to understand instructions for inserting a capsule into an inhaler to release the drug, and being able to insert the capsule. Failure to successfully perform this task could result in the patient swallowing the capsule instead of inhaling the contents, lack of treatment effect, or medication related adverse events. • The user being able to distinguish a product from others of similar appearance. Failure to successfully perform this task could result in delivery of the wrong drug. • The user being able to complete a series of several critical tasks required to prepare and administer a reconstituted drug from a combination product kit containing a prefilled diluent syringe, drug vial, empty syringe, needle, transfer device and infusion pump. These tasks could include preparing the drug under sterile conditions, connecting the system, and introducing the reconstituted drug solution into an infusion pump. Failure to successfully complete any of these tasks could result in medication errors and/or use- related infection. ## Appendix A: identifies task failures that may occur with general categories of combination products such as injectors and inhalers. The information can be used to guide the applicant when conducting a risk analysis, which is recommended for any combination product being developed. Additionally, these task failure examples may apply to other types of combination products, and can be used as a reference to help identify and evaluate hazards for other combination products. 18 For additional information on critical tasks, see Sections 7.3 and 7.4 of Applying Human Factors and Usability Engineering to Optimize Medical Device Design at http://www.fda.gov/RegulatoryInformation/Guidances/ucm259748.htm. Contains Nonbinding Recommendations 2. Intended Users and Use Environments Prior to performing a risk analysis, it is important to identify all intended users and use environments for the combination product. Intended users may be categorized into distinct user groups by their different characteristics (e.g., use responsibilities, tasks performed, age ranges, skills, or experience levels). For combination products, distinct user groups generally are health care professionals (HCPs) and lay users (non-health care professionals). Within these two groups there are likely further subgroups based on different tasks, roles, abilities and education. Subgroups of the HCP user population can include those with significantly different roles (e.g., nurses, pharmacists, physicians, emergency medical technicians, home health care providers). Also, within the HCP user population there may be individuals that have experience with the use of similar products and individuals that do not (e.g., injector-experienced vs nave) or that do or do not have experience with similar appearing products with different instructions for use or different hazards. In addition, both the professional role and experience of HCPs can influence interactions with a product. These various differences may justify treating HCPs as distinct user groups that should be evaluated in the HF study as such. Lay users (non-health care professionals) are those who use the product for self-administration (the patient) or those who administer the product to others as a caregiver (e.g., a family member, sports coach). Within this population, experience of individual users with similar products or products under development may vary widely. For example, when considering a drug- autoinjector combination product, some lay users may be nave to the use of any autoinjector or may be nave to the use of certain types of autoinjectors; e.g., those for single dose disposable versus single patient reusable products. Also, lay users may have experience with a different product that might influence their interaction. As a result of these differences, there may be distinct subgroups that should be considered in the use-related risk analysis. As applicable, the HF study should incorporate separate subgroups of lay users. Environments of use can have diverse characteristics that affect the users’ interactions with the product. Thus, the intended environment of use is another important consideration in designing a HF study. Combination products may be used in various professional health care / clinical settings that include emergency departments, intensive care units, inpatient bedsides, procedure suites, outpatient clinics, mobile units, and stocking and storage locations. Likewise, they can also be used in non-clinical settings including homes, schools, offices, and various modes of transportation (e.g., ambulances, airplanes). These environments may vary with respect to temperature, lighting and noise levels, ambient activity levels, number of people in the vicinity, and the availability of associated/accessory medication or devices. Also, a combination product that is intended for home use may be confused with other family member or pet medications stored in the same location. Such environmental conditions may lead to use errors. These environmental factors should be considered in the use-related risk analysis, and included within the design of the HF study as appropriate when they present a use hazard. 3. Training Training is often proposed as a way to mitigate or control risks. However, before determining if training is appropriate for the combination product, first it is important to eliminate risks that are inherent to the product design. If there are residual risks, the next step is to determine if training Contains Nonbinding Recommendations is needed. For example, for a new product that is developed as similar to or an alternative to a currently marketed product with use techniques that are well understood by the users, then training may not be necessary. Such an example might be a prefilled syringe with a staked needle for use by a health care professional. On the other hand, if there are residual risks for which training may be appropriate, the next step is to consider whether there is an opportunity for training, and if so, whether there is an expectation that training will routinely and consistently occur, before the first use of the combination product. In cases where training would be appropriate but is not expected to routinely or consistently occur, the HF study should evaluate the user interface in the absence of training.19 For combination products when training is expected or needed to control or mitigate residual use-related hazards, it is important to determine what the training is likely to encompass and how it will be performed, who is responsible for conducting the training, and how to ensure consistency in the training method. Consider, for example, a combination product being developed for a hospital-based surgical procedure. A risk analysis might determine that HCP training is required prior to the first use of the product to minimize the risk of errors related to assembling all the combination product constituent parts, preparing the treatment area and the surgical device constituent part before beginning the procedure, administering the drug constituent part(s), monitoring patient responses after using the product, and/or managing interactions across multiple users during the procedure. Due to the nature of the product and its use environment, all users would be expected to receive training before using the product. The HF study would evaluate the adequacy of the training in minimizing these potential risks. In this case, it is likely that FDA would not expect the HF study to evaluate the absence of training. In addition, when considering training to mitigate residual risks associated with the user interface, it is important to consider how frequently the training will occur, as well as the length of time between the training session(s) and product use. For some combination products, training and first product use is separated by days, weeks, or months. As such, a significant amount of time may elapse between the training session and product use. Retention of information from the first, and possibly the only, training a user receives can decrease over time (i.e., training decay). For example, for a combination product designed for once a week self- injection, post-training information retention one week later can be anticipated to be lower than it would one hour later. If the risk analysis shows that training decay is a source of use-related error, then the HF study design should evaluate the effect of training decay. The HF Validation study should simulate the effect training decay may have on the users; e.g., simulate the training decay by separating the training and simulated use testing by several hours or days. The protocol should justify the interval to simulate the training decay. C. Human Factors Formative Studies HF Formative studies are designed to evaluate early combination product prototypes, taking into consideration the identified use-related hazards. HF Formative study results guide prototype design changes to eliminate or mitigate use-related hazards identified during the product development process. The use of iterative HF Formative studies optimizes the design of the 19 As appropriate, if user training is necessary, applicants should discuss what methods are appropriate to ensure the provision of training. Contains Nonbinding Recommendations combination product user interface for safety, and minimizes the risk of first discovering use problems during late stages of development (e.g., during an HF Validation study, during a major clinical study, or after finalizing commercial plans.). Iterative HF Formative studies and related design modifications are performed until the user interface design appears to be sufficiently optimized for safety and ready for HF Validation testing. Iterative modifications to the user interface may include changes to the physical design attributes, changes to the packaging and labeling (including instructions for use) and changes to a training program. The results of HF Formative studies should inform the design of the final finished combination product. None of the individual subjects in the HF Formative studies should participate in the HF Validation studies to avoid the potential for bias. For information on HF Knowledge Task studies, see Section III.E; for information on HF Validation studies, see Section III.D below. D. Human Factors Validation Studies HF Validation studies demonstrate that the final finished combination product user interface would maximize the likelihood that the product will be safely and effectively used by intended users, for the intended uses in the intended use environments. There are two types of HF Validation studies: HF Simulated-Use and HF Actual-Use Validation. For most combination products, FDA expects that a HF Simulated-Use Validation study will be sufficient to assess the adequacy of the user interface. 1. Human Factors Simulated-Use Validation Studies The HF Simulated-Use Validation study focuses on confirming that the design of the final finished combination product (i.e., after iterative prototype design changes) user interface adequately mitigates or eliminates the identified use-related risks. Simulation methods for these studies vary and may include the use of a manikin, injection pads, placebo, and other elements intended to simulate the patient, the procedure, or the environment of use. The conditions of the HF Simulated-Use Validation study should be sufficiently realistic so that the results HF-Simulated-Use Validation represent relevant aspects of actual use of the product once introduced into the market. Tasks to be performed in the HF Simulated-Use Validation study should include those critical tasks identified in a use- related risk analysis that may be associated with user interface problems. The study design should provide for the identification of any unanticipated hazards or unexpected use behaviors that were not previously identified. 2. Human Factors Actual-Use Validation Studies As noted above, FDA expects that for most combination products, a HF Simulated-Use Validation study will be sufficient to assess the adequacy of the user interface design. However, there are rare circumstances when it is difficult to simulate the conditions of use, physical characteristics of the product, or environment of use. Thus, a HF Actual- Use Validation study may be needed to confirm the adequacy of the user interface design. Contains Nonbinding Recommendations HF Actual-Use Validation studies either (1) use the final finished combination product (including the drug, not a placebo) in a simulated use setting or (2) use the final finished combination product in a real (not simulated) environment of use. • A HF Actual-Use Validation study of the combination product that includes the actual drug in a simulated use setting may be necessary when the drug can affect the user’s ability to perform a critical task. For example, for a drug that causes coughing on inhalation which could result in incomplete dosing, inhaler designs to minimize the risk of not completing an inhalation could not be evaluated without use of the actual drug. This type of assessment using the drug-device combination product would otherwise occur in a simulated-use setting. • The other type of HF Actual-Use Validation study in a real environment of use. For example, based on the hazard analysis and results of an HF Simulated-Use Validation, it may be appropriate to evaluate in a real environment of use use- related risks associated with a complex combination product intended for use in crisis/emergency settings or with a combination product that has a complex operating procedure. In these instances, the user’s tasks could be influenced by the presence of noise, rapidly changing circumstances, distractions, etc. Therefore, the need for a HF Actual-Use Validation study is determined on a case-by-case basis. FDA recommends that applicants for combination products discuss with FDA the availability of simulation techniques and whether HF Simulated-Use Validation and HF Actual-Use Validation studies are needed to evaluate the user interface.20 Regardless of the type of HF Validation study, if use errors or problems (e.g., failures, “close calls,” use difficulties, and/or new findings) are identified in an HF Validation study, these should be evaluated to (1) identify the root cause(s), (2) determine the potential for harm (including the clinical significance of such errors or problems and the potential for compromised medical treatment), and (3) determine whether additional measures to eliminate or mitigate hazards are necessary. Regardless of the type of HF Validation study, if the HF Validation study shows that additional measures are necessary to address the risk of failures that are deemed clinically significant, then the HF Validation study will be considered failed. Changes to the user interface may be needed to eliminate or mitigate hazards and a new HF Validation study should be performed to evaluate the changes, with the goal of demonstrating that the modifications minimize the risk to acceptable levels without creating additional hazards. Also, if the product design changes or the user population changes, then the completed HF Validation study may or may not be applicable to the design change. A use-related risk analysis should be completed and, dependent upon the findings of the risk analysis, a new HF Validation study may be advisable to support that the modifications continue to minimize the risk without 20 The term “HF Actual-Use Validation study” has a different meaning than similar terms such as “user study” or “actual use study”. The term “HF Actual-Use Validation study” applies to only the evaluation of the user interface and associated critical tasks. In contrast, the terms “actual use” or “user study” (without the “HF” qualifier) often refer to clinical studies such as a major clinical study to evaluate safety and effectiveness of prolonged home use or to an open label safety study. Those studies have different purposes or mixed purposes and are outside the scope of this document. FDA recommends against referring to these different or mixed purpose studies as HF studies. Contains Nonbinding Recommendations creating additional hazards. If the product design remains unchanged but the applicant seeks to add a new user population, then as applicable, a new use-related risk analysis and new HF Validation study should be performed. See Section V for the relationship of the HF Validation study to the major clinical study. E. Human Factors Knowledge Task Studies In situations when the understanding of the information provided in a combination product’s labels or labeling is a critical task to using a product safely and effectively, a study to assess the user’s understanding of such information (Knowledge Task study) is appropriate. Knowledge Task studies may occur as part of the HF formative, or HF validation process. However, in comparison to other types of HF studies in which critical task performance is assessed by observing user interaction with the product, Knowledge Task studies focus on the understanding and interpretation of important information in the user interface that will be applied to make use- related decisions. The users’ understanding of the labeling is evaluated by questioning test participants and assessing whether the information has been understood. Knowledge Task studies may focus on particular aspects of labeling. For example, a Knowledge Task study could evaluate: • HCP’s understanding of their roles and responsibilities when introducing a combination product as part of a new procedure, or associated with complex medical/surgical procedures that involve many different HCPs; • The user’s ability to select the appropriate task from a lengthy set of instructions that include different options; • The user’s understanding of how to identify defective or expired product; • The user’s awareness and understanding of the combination product’s pertinent safety information provided in the instructions for use; • The user’s ability to recognize clinical signs, identified in the instructions for use, that would prompt medical attention; e.g., shortness of breath, allergic reaction, weakness, signs of disease progression; or • The user’s understanding of the diagrams provided in the labeling. Certain types of Knowledge Task studies are also used in the development of non-prescription products.21 Generally, these are quantitative studies that evaluate whether results are statistically significant. IV. PROCESS CONSIDERATIONS A. Considerations for Submission of Combination Product Human Factors Study Data For the following two groups of combination products, generally human factors data should be submitted: (1) products for use outside the health care environment or by laypersons (e.g., 21 For further information about such studies for non-prescription drug products, see Guidance to Industry Label Comprehension Studies for Nonprescription Drug Products, accessible at http://www.fda.gov/downloads/drugs/guidancecomplianceregulatoryinformation/guidances/ucm143834.pdf. Contains Nonbinding Recommendations home-use products, products for self-administration by patients or lay-caregivers) and (2) combination products having a device constituent part for which human factors data should be submitted. For combination products that do not fall within these two categories, a risk analysis for the combination product should be completed and the use-related risks reviewed to assess the need for HF studies (see section III.B). If the use-related risk analysis identifies the need for HF studies, then a HF Validation study should be conducted and the results submitted for review. For example, a syringe is not on the list of high priority devices for human factors review, and the following illustrates certain considerations for when a HF Validation study may be needed for a prefilled syringe. • A prefilled syringe with a staked needle and needle guard for use by HCPs in an acute care setting: o o If the syringe, needle and needle guard design is commonly used and well understood (absent other use-related risk concerns for the combination product as a whole), FDA would not expect a HF Validation study for such products. During the investigational phase when the applicant determines that a HF Validation study may not be needed, the applicant should submit its risk analysis and justification to support the basis of the applicant’s conclusion, and seek Agency comment on the assessment. If the syringe, needle and needle guard are of a unique/novel design, there are use experience concerns with similar products, or there are other factors that increase the use-related hazard, then an HF Validation study should be conducted. • The same prefilled syringe with needle guard for use by patients with neuromuscular disorder or visual impairment: o Because the user characteristics and associated medical symptoms present unique user profiles that may affect safe use of the product, an HF Validation study should be conducted to demonstrate that the product design adequately mitigates the risks for its intended use in these patients, and use environments. • The same prefilled syringe with needle guard and a unique application of color to distinguish it from different drugs in similar prefilled syringes to help prevent medication errors: o Even if factors such as indications for use, intended users, and use environment remain unchanged, based on the use-related risk analysis, an HF Validation study may be necessary to ensure that HCPs can readily distinguish the new syringe from similar prefilled syringes containing different drugs. As appropriate, such a study might focus on knowledge-based tasks. • The same prefilled syringe with needle guard that is used with various tubing, connectors, pumps and other device components in a high risk procedural setting: o A HF Validation study is likely necessary to assess the entire system. As applicable, the HF Validation study may include detailed assessments of the instructions, diagrams, training or other aspects that might become part of a postmarket safety program. Contains Nonbinding Recommendations Other scenarios and alternative approaches are possible. As with all product development, FDA encourages applicants to contact the Agency to discuss the specific product proposals. B. Considerations for Design Changes After HF Validation FDA recognizes that combination product design changes may occur premarket or postmarket after HF Validation studies have been completed. For example, during premarket development the results of a clinical trial may reveal design flaws that were not detected in HF Formative or HF Validation studies. Similarly, during postmarket development an applicant may plan a design change to the marketed combination product, for example, to respond to use-related safety reports, complaints/problems, to address a manufacturer-initiated postmarket corrective and preventative action plan, or to meet the needs of an expanded indication or user population. Some modifications to a product’s internal design or to some of its external features may not need validation in a HF study (e.g., a change in a material that does not affect user interface). However, design changes made after HF Validation that relate to identified critical tasks or may result in new use-related errors or hazards that could lead to harm should have new HF Validation study assessments. When making design changes, the applicant should conduct an updated use-related risk assessment of the new design. FDA encourages applicants to follow the HF principles outlined in this document. Conceptually, this analysis should consider such things as: • Does the design change alter the user interface in any way (e.g., audible, tactile, color recognition, user instructions, etc.)? • Does the design change alter an existing critical task or add a new critical task? • Does the design change alter the expected users or their knowledge base? To facilitate discussion with FDA, the applicant should provide a proposal about what, if any, additional HF testing is needed. The proposal should include a detailed description of why the change is being made, a description of what specifically is changing, a use-related risk analysis of the new design, and where appropriate a proposal for evaluating potential risk mitigations of the new design and the effects of the change. When making a design change to a combination product, FDA encourages applicants to expeditiously identify the change plans and to discuss with the Agency the types of HF and other clinical or non-clinical studies that may be applicable before the applicant’s approval of the design change.22 (Also, see Section IV.A for further information that may be useful in considering the HF implications of a design change.) C. Review of Human Factors Information in Combination Product Investigational Applications The combination product’s specific use-related risk analysis generally informs the Agency’s expectations for whether HF information on a combination product should be submitted in an 22 The use of other types (i.e., non-HF) of studies (e.g., clinical, pharmacokinetic, or non-clinical studies) to evaluate combination product design changes is beyond the scope of this document. Contains Nonbinding Recommendations investigational application. The risk analysis itself should be submitted in the investigational application for the combination product. If the applicant determines from the risk analysis that a HF study is not needed, the applicant should provide the use-related risk analysis along with the justification for this conclusion. If the use-related risk analysis indicates that a HF study is necessary, FDA encourages applicants to submit the following HF information for feedback before commencing the HF Validation study: • Use-related risk analysis and any updated risk analysis of design changes; • A summary of HF Formative study results and analysis; • A summary of changes made to the product user interface after the HF Formative studies, including how the results from the HF Formative studies were used to update the user interface and use-related risk analysis; • The draft HF Validation study protocol; and • Intend-to-market labels and labeling (including instructions for use if any are proposed) that will be tested in the HF Validation study. When this information is submitted to the investigational application, FDA will review the information, including the use-related risk analysis and the draft HF Validation study protocol, and intends to provide comments or recommendations to increase the likelihood of an acceptable HF study design that will adequately test for potential use failures. Also, during Agency review of draft HF Validation study protocols that include product labeling (e.g., instructions for use), FDA intends to provide preliminary comments on the user interface labels and labeling being However, final labeling is determined after review of the entire marketing application that includes information beyond that in the HF Validation study. D. Review of HF Studies and Certain Labeling in Marketing Applications As applicable, FDA will review HF Validation study results submitted in the marketing application to assess whether the data confirm validation of the user interface and certain aspects of the proposed labels and labeling (e.g., instructions for use). FDA cautions applicants leveraging a master file for HF data, that in some instances the master file data may suffice for one constituent part alone, but not for the combination product as a whole (e.g., device with a specific drug/biological product). The applicant should determine whether sufficient information would be available in the master file or whether the applicant should conduct and submit additional HF studies for the combination product as a whole. During FDA review of labeling23 in a marketing application, FDA may determine that the final user interface labeling should differ from the HF Validated labeling. This may occur, for example, based on the results of the major clinical trial, other safety data or medication error data, new nomenclature considerations, and labeling content and format requirements. The labeling assessment also considers current postmarket experience with the same or similar products, which might indicate that modification of the instructions for use is appropriate to mitigate a risk. After review of the marketing application, depending on the potential impact of resulting labeling differences on performance of critical tasks, an additional HF Validation study 23 Labeling review includes consideration of labeling claims that might be provided by a HF study (e.g., user preference or ease of use) and whether the data support those claims. Contains Nonbinding Recommendations may be needed to ensure that the changes minimize the use-related risks without creating additional hazards. V. RELATIONSHIP OF HUMAN FACTORS AND MAJOR CLINICAL STUDIES OF THE COMBINATION PRODUCT As explained in preceding sections of this document, HF studies of a combination product are conducted as part of the product design controls process. An appropriate HF development program will maximize the likelihood that the combination product user interface is safe and effective for use by the intended users, uses and use environments. However, the HF Validation study is not sufficient to establish the safety and effectiveness of the combination product for the proposed indication. Specifically, data from the major clinical study(ies) establish the combination product’s safety and effectiveness for the proposed indication and the complete labeling summarizes the essential scientific information needed for the safe and effective use of the product.24 Therefore, ideally, before conducting the major clinical study(ies), the HF Validation study should be conducted on the final finished combination product, including the user interface (e.g., instructions for use, training materials, and any other user labeling, if applicable). The HF Validated product would then be ready for further evaluation in the major clinical study(ies) that will be submitted in the marketing application. Noting that in some cases it may be appropriate to conduct your human factors studies in parallel to your major clinical studies or after your clinical studies to address modifications to your product. FDA recognizes that in some circumstances the data to support safety and efficacy of the combination product may adequate without the inclusion of the final finished combination in a major clinical trial. For certain products, the sequencing of the HF study prior to the clinical study may be less critical to inform our understanding of the product’s safety and efficacy, allowing for greater flexibility in the timing of the human factors validation study relative to a major clinical studies. In other cases, a sponsor may encounter a need to change the combination product design in the course of the development program, even after clinical studies have been completed. The type and extent of data to support such changes depend on the nature of change, development stage, and other contextual factors, and FDA would consider the totality of the data provided to support the approvability of the combination product in any such circumstances. However, for certain combination products, we might expect or encourage you to use the final finished combination product in your major clinical studies. In such cases, we recommend that you conduct the HF-Validation study on the final finished combination product prior to the major clinical studies. And, in all cases, we encourage you to discuss your combination product development plans with the Agency as appropriate and consider such discussion as a component of your development meeting, including the pre-IND, IDE and EOP2 meetings 24 See 21CFR 201.56(a)(1). Contains Nonbinding Recommendations VI. HOW TO OBTAIN ADDITIONAL INFORMATION FDA encourages applicants to request early discussions with FDA regarding their HF program and the type of HF studies that might be appropriate or necessary in the planned submission. Additionally, if applicants anticipate design changes during product development before launch, FDA strongly encourages meetings during the early planning stages. Discussion topics might include how to add a new configuration to the development plan and/or how to bridge to existing data. Such discussions should provide clarity on the applicant’s development plan and provide transparency on FDA recommendations and expectations on HF studies and sequence of the development program. Where appropriate, the applicant may request focused meetings for more detailed discussions. For a combination product, applicants should submit meeting requests to the lead center using the process and procedures of the lead center. The meeting request should indicate that the discussion is for a combination product and request participation of all relevant centers and Office of Combination Products as appropriate. Additional information on requesting meetings is provided in the last two guidance documents listed below. The following FDA documents may be useful: • Guidance for Industry and FDA Staff – Applying Human Factors and Usability Engineering to Optimize Medical Device Design; http://www.fda.gov/MedicalDevices/DeviceRegulationandGuidance/GuidanceDocument s/ucm259748.htm • Draft Guidance for Industry – Safety Considerations for Product Design to Minimize Medication Errors; http://www.fda.gov/downloads/Drugs/GuidanceComplianceRegulatoryInformation/Guid ances/UCM331810.pdf • Draft Guidance for Industry – Safety Considerations for Container Labels and Carton Labeling Design to Minimize Medication Errors; http://www.fda.gov/downloads/drugs/guidancecomplianceregulatoryinformation/guidanc es/ucm349009.pdf • Guidance for Industry – Label Comprehension Studies for Nonprescription Drug Products; http://www.fda.gov/downloads/drugs/guidancecomplianceregulatoryinformation/guidanc es/ucm143834.pdf • Draft Guidance for Industry – Format and Content of Proposed Risk Evaluation and Mitigation Strategies (REMS), REMS Assessments, and Proposed REMS Modifications; http://www.fda.gov/downloads/drugs/guidancecomplianceregulatoryinformation/guidanc es/ucm184128.pdf • Guidance for Industry – Formal Meetings Between FDA and Sponsors or Applicants; http://www.fda.gov/downloads/drugs/guidancecomplianceregulatoryinformation/guidanc es/ucm153222.pdf • Guidance for Industry and FDA Staff – Requests for Feedback on Medical Device Submissions: The Pre-Submission Program and Meetings with Food and Drug Administration Staff; http://www.fda.gov/downloads/medicaldevices/deviceregulationandguidance/guidancedo cuments/ucm311176.pdf Contains Nonbinding Recommendations ## APPENDIX A: USER TASK FAILURE EXAMPLES Table 1 and Table 2 below provide examples of some user task failures that typically apply to injection and inhalation combination products. Table 1 applies to combination products with injectors (e.g., pen injectors, autoinjectors, prefilled syringes), and Table 2 applies to combination products with certain inhalation systems (e.g., nebulizers and inhalers). In addition to the examples in these tables, there may be knowledge tasks that require user understanding of information that is not typically or easily evaluated through observation of simulated use. Knowledge tasks are derived from the product labeling (including user manual, Medication Guide, labels on the device itself) and training package. The tables do not present comprehensive all-inclusive lists. If the combination product requires users to perform tasks not contained in the tables that could result in harm if not performed correctly, then those tasks should be included in the HF Validation study. Also, depending upon the product design, only certain tasks may be applicable to a specific combination product. The critical tasks may change depending on the indications, use environments, user populations that have unique or novel risks, and other characteristics and features of the combination product. Therefore, a use-related risk analysis should be performed before identifying tasks for evaluation in a HF Validation study. Once identified, those tasks should be used to construct the HF Validation study. (Intentionally blank) Contains Nonbinding Recommendations Table 1: Examples of Critical Tasks for Combination Products that Deliver Dose by Injection User Task Possible Task Failures and Use Errors Understand how to dose the product • Misunderstanding dosing instructions • Not aware of dosing instructions Understand how to administer the product • Improper technique while interacting with the product during dosing • Cannot complete injection Product differentiation Open packaging Evaluate device and drug prior to dosing Prepare injection site Prepare/mix the dose for injection • Select incorrect product • Damage to device • Loss of instructions or components • Inability to open package • Failure to check injector window for drug condition • Expired or adulterated drug used • Use device that is not functional for dose delivery • Use damaged needle • Not cleaning/disinfecting injection site • Mix or Measure the product incorrectly • Wrong drug amount drawn into the syringe Prime injector/syringe for injection. Select injection site • Not priming at all or priming incorrectly Identify incorrect injection site • Remove syringe needle cover Attach needle • Do not remove needle cover or injector cap • Do not attach needle Remove injector cap • Do not remove injector cap Hold injector/syringe in correct orientation • Hold injector/syringe incorrectly • Inject upside down Depress syringe plunger/ activate autoinjector (press injection button) Hold syringe or injector at injection site • Unable to depress the plunger • Unable to activate injector fully • Unable to determine if dose delivered • Premature removal of syringe/injector • Wet injection (drug solution on surface Verify dose delivery • Not verifying complete dose delivery of injection site) Dispose/clean/store syringe/injector • Improper disposal/storage • Inject degraded product • Do not clean reusable device Possible Hazard / Harm Resulting from Failures/Use Errors • Overdosing • Under dosing • Missed dose • Overdosing • Under dosing • Missed dose • Needlestick injury • Accidental exposure to others • Wrong drug delivered • Delay of therapy • Missed dose • Over or under dosing • User injury • Painful injection • Reduced drug efficacy • Delay of therapy • Missed dose • Infection Infection Inaccurate dosing • • Reduced drug efficacy • Under dosing • Overdosing • • Under dosing • Painful injection • Lack of drug efficacy • Local or systemic adverse events • Missed dose • Delay of therapy • Missed dose • Delay of therapy • Missed dose • Delay of therapy • Needle stick injuries • Delay of therapy • Reduced drug efficacy • No dose • Under dosing • Under dosing • Missed dose • Under dosing • Missed dose • Needle stick injuries • Contamination /transmission of disease (infection) • Reduced drug efficacy • Delay of therapy • Drug diversion • Exposure of non-users Contains Nonbinding Recommendations Table 2: Examples of Critical Tasks for Combination Products that Deliver Dose by Inhalation User Task Possible Task Failures and Use Errors Understand how to administer the product Understand how the product to dose Open packaging Assemble product Evaluate device and drug prior to dosing Set up dose; prime product Use device to deliver dose Waiting a specific amount of time between doses for multiple breath dosing Disassemble, maintain, store, and clean reusable device components Dispose of device as per instructions. • • • • • • • • • • • • • • • • Improper technique while using the product during dosing Cannot complete inhalation Misunderstanding dosing instructions Not aware of dosing instructions Damage to device Loss of instructions or components Inability to open package Assembled incorrectly Unable to assemble Expired or adulterated drug used Use device that is not functional for dose delivery Use damaged product Not preparing dose for inhalation Not priming at all or priming incorrectly Improper inhalation technique Improper seal of mouth on mouthpiece • Not waiting long enough between doses Possible Hazard / Harm Resulting from Failures/Use Errors • • • • • • • • • • • • • • • • • Overdosing Under dose Missed dose Accidental exposure to others Overdosing Under dosing Missed dose Delay of therapy Missed dose Wrong dose User injury Choking on device components Delay of therapy Missed dose or dosing error Reduced drug efficacy Delay of therapy Missed dose or dosing error • • • • • • • • Under dosing or overdosing Choking on dose capsule (if present) Missed dose Under dosing or over-dosing Missed dose or dosing error Coughing Under dose Lack of efficacy • Failing to clean or maintain. • Storing at wrong temperature or under other incorrect conditions • Failing to properly dispose of device • Delay of therapy • Under dosing or overdosing • • • • Infection Reduced drug efficacy Diversion of drug Exposure to non-users --- ### Document: FDA ContainerClosure Complete (FDA) # FDA Guidance for Industry: Container Closure Systems for Packaging Human Drugs and Biologics — CMC Documentation (1999) Guidance for Industry Container Closure Systems for Packaging Human Drugs and Biologics CHEMISTRY, MANUFACTURING, AND CONTROLS DOCUMENTATION U.S. Department of Health and Human Services Food and Drug Administration Center for Drug Evaluation and Research (CDER) Center for Biologics Evaluation and Research (CBER) May 1999 Guidance for Industry Container Closure Systems for Packaging Human Drugs and Biologics CHEMISTRY, MANUFACTURING, AND CONTROLS DOCUMENTATION Additional copies are available from: Office of Training and Communications Division of Communications Management Drug Information Branch, HFD-210 Center for Drug Evaluation and Research (CDER) 5600 Fishers Lane Rockville, Maryland 20857 (Tel) 301-827-4573 (Internet) http://www.fda.gov/cder/guidance/index.htm or Office of Communications Training and Manufacturers Assistance, HFM-40 Center for Biologics Evaluation and Research (CBER) 1401 Rockville Pike Rockville, Maryland 20852-1448 (Fax) 888-CBERFAX or 301-827-3844 (Voice Information) 800-835-4709 or 301-827-1800 (Internet) http://www.fda.gov/cber/guidelines.htm U.S. Department of Health and Human Services Food and Drug Administration Center for Drug Evaluation and Research (CDER) Center for Biologics Evaluation and Research (CBER) May 1999 Table of Contents I. INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 II. BACKGROUND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 A. Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 B. CGMP, CPSC and USP Requirements on Containers and Closures . . . . . . . . . . . 3 C. Additional Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 III. QUALIFICATION AND QUALITY CONTROL OF PACKAGING COMPONENTS . 5 A. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 B. General Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 C. Information That Should Be Submitted in Support of an Original Application for Any Drug Product . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 D. Inhalation Drug Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 E. Drug Products for Injection and Ophthalmic Drug Products . . . . . . . . . . . . . . . 23 F. Liquid-Based Oral and Topical Drug Products and Topical Delivery Systems . . 27 G. Solid Oral Dosage Forms and Powders for Reconstitution . . . . . . . . . . . . . . . . 33 H. Other Dosage Forms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 IV. POSTAPPROVAL PACKAGING CHANGES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 V. TYPE III DRUG MASTER FILES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 A. General Comments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 B. Information in a Type III DMF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 VI. BULK CONTAINERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 A. Containers for Bulk Drug Substances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 B. Containers for Bulk Drug Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 ATTACHMENT A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1 REGULATORY REQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1 ATTACHMENT B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-1 COMPLIANCE POLICY GUIDES THAT CONCERN PACKAGING . . . . . . . . . . B-1 ATTACHMENT C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-1 EXTRACTION STUDIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-1 ATTACHMENT D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-1 ABBREVIATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-1 ATTACHMENT E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-1 REFERENCES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-1 This guidance has been prepared by the Packaging Technical Committee of the Chemistry, Manufacturing, and Controls Coordinating Committee (CMC CC) in the Center for Drug Evaluation and Research (CDER) and in conjunction with the Center for Biologics Evaluation and Research (CBER) at the Food and Drug Administration. This guidance document represents the Agency's current thinking on container closure systems for the packaging of human drugs and biological products. It does not create or confer any rights for or on any person and does not operate to bind FDA or the public. An alternative approach may be used if such approach satisfies the requirements of the applicable statute, regulations, or both. In general, this guidance does not suggest specific test methods and acceptance criteria (except for references to The United States Pharmacopia methods), nor does it suggest comprehensive lists of tests. These details should be determined based on good scientific principles for each specific container closure system for particular drug product formulations, dosage forms, and routes of administration. Acceptance criteria should be based on actual data for particular packaging components and container closure systems, and they should be set to ensure batch-to-batch uniformity of packaging components. As used in this guidance, the terms drug and drug product include biologics unless otherwise noted. The policy statement is a document titled Container/Closure Information Which Should Be Provided In An ANDA/AADA which was written by the Office of Generic Drugs/Packaging Advisory Group. GUIDANCE FOR INDUSTRY1 CONTAINER CLOSURE SYSTEMS FOR PACKAGING HUMAN DRUGS AND BIOLOGICS CHEMISTRY, MANUFACTURING, AND CONTROLS DOCUMENTATION I. INTRODUCTION This document is intended to provide guidance on general principles for submitting information on packaging materials used for human drugs and biologics. This guidance supersedes the FDA Guideline for Submitting Documentation for Packaging for Human Drugs and Biologics, issued in February 1987 and the packaging policy statement issued in a letter to industry dated June 30, 1995 from the Office of Generic Drugs. This guidance is not intended to describe the information that should be provided about packaging operations associated with drug product manufacture. Approaches which differ from those described in this guidance may be followed, but the applicant is encouraged to discuss significant variations in advance with the appropriate CDER chemistry review staff or CBER review staff. This is to prevent applicants or sponsors from spending unnecessary time and effort in preparing a submission that the FDA may later determine to be unacceptable. These definitions are intended to clarify the use of certain terms in this guidance only and are not intended to supersede the definitions of container and package as provided for in 21 CFR 600.3. This term is used in a general sense for the basic material, which should be defined in the application in terms of its specific chemical composition for a given drug application (e.g., the specific polymer and any additives used to make the material). II. BACKGROUND The Federal Food, Drug, and Cosmetic Act (the Act) mandates the need for adequate information related to packaging materials. Section 501(a)(3) of the Act states that a drug is deemed to be adulterated "if its container is composed, in whole or in part, of any poisonous or deleterious substance which may render the contents injurious to health...." In addition, section 502 of the Act states that a drug is considered misbranded if there are packaging omissions. Also, section 505 of the Act requires a full description of the methods used in, and the facilities and controls used for, the packaging of drugs (see Attachment A). Section 505(b)(1)(D) of the Act states that an application shall include a full description of the methods used in, the manufacturing, processing and packing of such drug. This includes facilities and controls used in the packaging a drug product. A. Definitions5 Materials of construction refer to the substances (e.g., glass, high density polyethylene (HDPE) resin, metal) used to manufacture a packaging component. A packaging component means any single part of a container closure system. Typical components are containers (e.g., ampules, vials, bottles), container liners (e.g., tube liners), closures (e.g., screw caps, stoppers), closure liners, stopper overseals, container inner seals, administration ports (e.g., on large-volume parenterals (LVPs)), overwraps, administration accessories, and container labels. A primary packaging component means a packaging component that is or may be in direct contact with the dosage form. A secondary packaging component means a packaging component that is not and will not be in direct contact with the dosage form. A container closure system refers to the sum of packaging components that together contain and protect the dosage form. This includes primary packaging components and secondary packaging components, if the latter are intended to provide additional protection to the drug product. A packaging system is equivalent to a container closure system. The materials of construction used in the labeling are a concern from a packaging perspective if they affect the protection and/or safety of the drug product. A package or market package refers to the container closure system and labeling, associated components (e.g., dosing cups, droppers, spoons), and external packaging (e.g., cartons or shrink wrap). A market package is the article provided to a pharmacist or retail customer upon purchase and does not include packaging used solely for the purpose of shipping such articles. Quality refers to the physical, chemical, microbiological, biological, bioavailability, and stability attributes that a drug product should maintain if it is to be deemed suitable for therapeutic or diagnostic use. In this guidance, the term is also understood to convey the properties of safety, identity, strength, quality, and purity (see 21 CFR 211.94(a)). An extraction profile refers to the analysis (usually by chromatographic means) of extracts obtained from a packaging component. A quantitative extraction profile is one in which the amount of each detected substance is determined. B. CGMP, CPSC and USP Requirements on Containers and Closures Current good manufacturing practice (CGMP) requirements for the control of drug product containers and closures are included in 21 CFR Parts 210 and 211. A listing of the relevant sections is provided in Attachment A. In addition, a listing of Compliance Policy Guides that deal with packaging issues is provided in Attachment B. References in this guidance to CGMP regulations are provided for completeness. For additional information, refer to the FDA Compliance Program Guidance Manual for Pre-Approval Inspections/Investigations (7346.832) which describes specific responsibilities for CDER scientists and for field investigators. The FDA requirement for tamper-resistant closures is included in 21 CFR 211.132 and the Consumer Product Safety Commission (CPSC) requirements for child-resistant closures are included in 16 CFR 1700. An outline of these and other applicable regulatory requirements is provided in Attachment A. The United States Pharmacopeial Convention has established requirements for containers which are described in many of the drug product monographs in The United States Pharmacopeia/National Formulary (USP/NF). For capsules and tablets, these requirements generally relate to the design characteristics of the container (e.g., tight, well-closed or light-resistant). For injectable products, materials of construction are also addressed (e.g., "Preserve in single-dose or in multiple-dose containers, preferably of Type I glass, protected from light"). These requirements are defined in the "General Notices and Requirements" (Preservation, Packaging, Storage, and Labeling) section of the USP. The requirements for materials of construction are defined in the "General Chapters" of the USP (see Attachment A). C. Additional Considerations 1. Submissions of INDs The packaging information in the chemistry, manufacturing, and controls section of an IND usually includes a brief description of the components, the assembled packaging system and any precautions needed to ensure the protection and preservation of the drug substance and drug product during their use in the clinical trials. For general guidance regarding the container closure system information to be submitted for phase 1 studies, refer to the FDA guidance for industry Content and Format of investigational New Drug Applications(INDs) for Phase 1 Studies of Drugs, Including Well-Characterized, Therapeutic, Biotechnology-derived Products (November 1995). General guidance regarding the container closure system information to be submitted for phase 2 or phase 3 studies will be provided in the FDA guidance for industry INDs for Phase 2 and 3 Studies of Drugs, Including Specified Therapeutic Biotechnology-Derived Products, Chemistry, Manufacturing, and Controls Content and Format, when finalized (draft guidance published April 21, 1999). 2. Submissions on Packaging of a Drug Product by Another Firm a. Contract Packager A contract packager is a firm retained by the applicant to package a drug product. The applicant remains responsible for the quality of the drug product during shipping, storage, and packaging. The information regarding the container closure system used by a contract packager that should be submitted in the CMC section of an application (NDA, ANDA, or BLA), or in a DMF which is referenced in the application, is no different from that which would be submitted if the applicant performed its own packaging operations. If the information is provided in a DMF, then a copy of the letter of authorization (LOA) for the DMF should be provided in the application (see section V.A). This discussion does not apply to the repackaging of drug products for dispensing under the practice of pharmacy. FDA Compliance Policy Guides, “Expiration Dating of Unit Repackaged Drugs,” 480.200, February 1, 1984, rev. March 1995 (CPG 7132b.11). FDA Compliance Policy Guides, "Regulatory Action Regarding Approved New Drugs and Antibiotic Drug Products Subjected to Additional Processing or Other Manipulation," 446.100, January 18, 1991 (CPG 7132c.06). b. Repackager8 A repackager is a firm that buys drug product from the drug product manufacturer or distributor and repackages it for sale under a label different from that of the manufacturer. The repackager is responsible for ensuring the quality and stability of the repackaged drug prpoduct. The repackaging operation is required to e in compliance with CGMPs (21 CFR Part 211), and there are limits to the expiration period that may be used with the repackaged product unless the repackager conducts stability studies. Packaging qualification information is not required if the repackager uses the same container closure system approved in the original application. All significant phases of the manufacturing and processing of a drug product (including packaging) should be described as part of the CMC section of an application (NDA, ANDA or BLA), or in a DMF referenced in the application. The only exception is the repackaging of solid oral drug products for which an approved application already exists. For biologics, repackaging is considered a step in the manufacturing process for which licensing is required (21 CFR 600.3(u) and 601). III. QUALIFICATION AND QUALITY CONTROL OF PACKAGING COMPONENTS A. Introduction CDER and CBER approve a container closure system to be used in the packaging of a human drug or biologic as part of the application (NDA, ANDA or BLA) for the drug or biologic. A packaging system found acceptable for one drug product is not automatically assumed to be appropriate for another. Each application should contain enough information to show that each proposed container closure system and its components are suitable for its intended use. The type and extent of information that should be provided in an application will depend on the dosage form and the route of administration. For example, the kind of information that should be provided about a packaging system for an injectable dosage form or a drug product for inhalation is often more detailed than that which should be provided about a packaging system for a solid oral dosage form. More detailed information usually should be provided for a liquid-based dosage form than for a powder or a solid, since a liquid- based dosage form is more likely to interact with the packaging components. Table 1 illustrates the correlation between the degree of concern regarding the route of administration with the likelihood of packaging component-dosage form interactions for different classes of drug products. Table 1 Examples of Packaging Concerns for Common Classes of Drug Products Degree of Concern Likelihood of Packaging Component-Dosage Form Interaction Associated with the Route of Administration High Medium Low Highest Inhalation Aerosols Sterile Powders and and Solutions; Powders for Injections and Injection; Inhalation Injectable Powders Suspensionsa High Ophthalmic Solutions and Suspensions; Transdermal Ointments and Patches; Nasal Aerosols and Sprays Low Topical Solutions and Topical Powders; Oral Tablets and Oral Suspensions; Topical Oral powders (Hard and Soft and Lingual Aerosols; Gelatin) Capsules Oral Solutions and Suspensions For the purposes of this table, the term suspension is used to mean a mixture of two a immiscible phases (e.g., solid in liquid or liquid in liquid). As such, it encompasses a wide variety of dosage forms such as creams, ointments, gels, and emulsions, as well as suspensions in the pharmaceutical sense. For the purpose of this guidance, container closure systems for the most common types of dosage forms will be discussed in terms of five general categories: Inhalation Drug Products (section III.D); Drug Products for Injection and Ophthalmic Drug Products (Section III.E); Liquid-based Oral and Topical Drug Products and Topical Delivery Systems (section III.F); Solid Oral Dosage Forms and Powders for Reconstitution (section III.G); and Other Dosage Forms (section III.H). B. General Considerations Suitability refers to the tests and studies used and accepted for the initial qualification of a component or a container closure system for its intended use. Quality control (QC) refers to the tests typically used and accepted to establish that, after the application is approved, the components and the container closure system continue to possess the characteristics established in the suitability studies. The subsections on associated components and secondary components describe the tests and studies for establishing suitability and quality control for these types of components. However, the ultimate proof of the suitability of the container closure system and the packaging process is established by full shelf life stability studies. 1. Suitability for the Intended Use Every proposed packaging system should be shown to be suitable for its intended use: it should adequately protect the dosage form; it should be compatible with the dosage form; and it should be composed of materials that are considered safe for use with the dosage form and the route of administration. If the packaging system has a performance feature in addition to containing the product, the assembled container closure system should be shown to function properly. Information intended to establish suitability may be generated by the applicant, by the supplier of the material of construction or the component, or by a laboratory under contract to either the applicant or the firm. An adequately detailed description of the tests, methods, acceptance criteria, reference standards, and validation information for the studies should be provided. The information may be submitted directly in the application or indirectly by reference to a DMF. If a DMF is used, a letter authorizing reference (i.e., letter of authorization (LOA)) to the DMF must be included in the application (see section V.A). General issues concerning protection, compatibility, safety and performance of packaging components and/or systems are discussed below. In this guidance, component functionality and drug delivery will also be addressed in connection with specific dosage forms and routes of administration (see sections III.D, III.E, III.F, III.G, and III.H). a. Protection A container closure system should provide the dosage form with adequate protection from factors (e.g., temperature, light) that can cause a degradation in the quality of that dosage form over its shelf life. Common causes of such degradation are: exposure to light, loss of solvent, exposure For further information regarding photostability studies, see the FDA Guideline for the Photostability Testing of New Drug Substances and Products (May 1997). to reactive gases (e.g., oxygen), absorption of water vapor, and microbial contamination. A drug product can also suffer an unacceptable loss in quality if it is contaminated by filth. Not every drug product is susceptible to degradation by all of these factors. Not all drug products are light sensitive. Not all tablets are subject to loss of quality due to absorption of moisture. Sensitivity to oxygen is most commonly found with liquid-based dosage forms. Laboratory studies can be used to determine which of these factors actually have an influence on a particular drug product. Light protection is typically provided by an opaque or amber-colored container or by an opaque secondary packaging component (e.g., cartons or overwrap). The USP test for light transmission (USP <661>) is an accepted standard for evaluating the light transmission properties of a container. Situations exist in which solid and liquid-based oral drug products have been exposed to light during storage because the opaque secondary packaging component was removed, contrary to the approved labeling and the USP monograph recommendation. A firm, therefore, may want to consider using additional or alternate measures to provide light protection to these drug products when necessary. Loss of solvent can occur through a permeable barrier (e.g., a polyethylene container wall), through an inadequate seal, or through leakage. Leaks can develop through rough handling or from inadequate contact between the container and the closure (e.g., due to the buildup of pressure during storage). Leaks can also occur in tubes due to a failure of the crimp seal. Water vapor or reactive gases (e.g., oxygen) may penetrate a container closure system either by passing through a permeable container surface (e.g., the wall of a low density polyethylene (LDPE) bottle) or by diffusing past a seal. Plastic containers are susceptible to both routes. Although glass containers would seem to offer better protection, because glass is relatively impermeable, glass containers are more effective only if there is a good seal between the container and the closure. Protection from microbial contamination is provided by maintaining adequate container integrity after the packaging system has been sealed. An adequate and validated procedure should be used for drug product manufacture and packaging. b. Compatibility Packaging components that are compatible with a dosage form will not interact sufficiently to cause unacceptable changes in the quality of either the dosage form or the packaging component. Examples of interactions include loss of potency due to absorption or adsorption of the active drug substance, or degradation of the active drug substance induced by a chemical entity leached from a packaging component; reduction in the concentration of an excipient due to absorption, adsorption or leachable-induced degradation; precipitation; changes in drug product pH; discoloration of either the dosage form or the packaging component; or increase in brittleness of the packaging component. Some interactions between a packaging component and dosage form will be detected during qualification studies on the container closure system and its components. Others may not show up except in the stability studies. Therefore, any change noted during a stability study that may be attributable to interaction between the dosage form and a packaging component should be investigated and appropriate action taken, regardless of whether the stability study is being conducted for an original application, a supplemental application, or as fulfillment of a commitment to conduct postapproval stability studies. c. Safety Packaging components should be constructed of materials that will not leach harmful or undesirable amounts of substances to which a patient will be exposed when being treated with the drug product. This consideration is especially important for those packaging components which may be in direct contact with the dosage form, but it is also applicable to any component from which substances may migrate into the dosage form (e.g., an ink or adhesive). Making the determination that a material of construction used in the manufacture of a packaging component is safe for its intended use is not a simple process, and a standardized approach has not been established. There is, however, a body of experience which supports the use of certain approaches that depend on the route of administration and the likelihood of interactions between the component and the dosage form (see Table 1). For a drug product such as an injection, inhalation, ophthalmic, or transdermal, a comprehensive study is appropriate. This involves two See Attachment C for discussion of extraction studies. FDA/CFSAN, Recommendations for Chemistry Data for Indirect Food Additive Petitions, Version 1.2, Chemistry Review Branch, Office of Pre-Market Approval, June 1995. parts: first, an extraction study on the packaging component to determine which chemical species may migrate into the dosage form (and at what concentration); and, second, a toxicological evaluation of those substances which are extracted to determine the safe level of exposure via the label specified route of administration. This technique is used by the Center for Food Safety and Applied Nutrition (CFSAN) to evaluate the safety of substances that are proposed as indirect food additives (e.g., polymers or additives that may be used in for packaging foods).13 The approach for toxicological evaluation of the safety of extractables should be based on good scientific principles and take into account the specific container closure system, drug product formulation, dosage form, route of administration, and dose regimen (chronic or short-term dosing). For many injectable and ophthalmic drug products (see sections III.E and III.F), data from the USP Biological Reactivity Tests and USP Elastomeric Closures for Injections tests will typically be considered sufficient evidence of material safety. For many solid and liquid oral drug products, an appropriate reference to the indirect food additive regulations (21 CFR 174-186) promulgated by CFSAN for the materials of construction used in the packaging component will typically be considered sufficient. Although these regulations do not specifically apply to materials for packaging drug products, they include purity criteria and limitations pertaining to the use of specific materials for packaging foods that may be acceptable for the evaluation of drug product packaging components. Applicants are cautioned that this approach may not be acceptable for liquid oral dosage forms intended for chronic use (see section III.F.1). For drug products that undergo clinical trials, the absence of adverse reactions traceable to the packaging components is considered supporting evidence of material safety. Safety assessments for specific dosage forms are discussed further in section III of this guidance. d. Performance Performance of the container closure system refers to its ability to function in the manner for which it was designed. A container closure system is often called upon to do more than simply contain the dosage form. When evaluating performance, two major considerations are container closure system functionality and drug delivery. i. Container Closure System Functionality The container closure system may be designed to improve patient compliance (e.g., a cap that contains a counter), minimize waste (e.g., a two-chamber vial or IV bag), improve ease of use (e.g., a prefilled syringe), or have other functions. ii. Drug Delivery Drug delivery refers to the ability of the packaging system to deliver the dosage form in the amount or at the rate described in the package insert. Some examples of a packaging system for which drug delivery aspects are relevant are a prefilled syringe, a transdermal patch, a metered tube, a dropper or spray bottle, a dry powder inhaler, and a metered dose inhaler. Container closure system functionality and/or drug delivery are compromised when the packaging system fails to operate as designed. Failure can result from misuse, faulty design, manufacturing defect, improper assembly, or wear and tear during use. Tests and acceptance criteria regarding dosage form delivery and container closure system functionality should be appropriate to the particular dosage form, route of administration, and design features. e. Summary Table 2 summarizes typical packaging suitability considerations for common classes of drug products. Table 2 Typical Suitability Considerations for Common Classes of Drug Products (This table is a general guide, and is not comprehensive. See sections III.C through III.H for a more detailed discussion.) Route of Administration/ Dosage Form SUITABILITYa Protection Compatibility Safety Drug Performance/ Delivery Inhalation Aerosols and Solutions, Nasal Sprays L, S, M, W, G Case 1c Case 1s Case 1d Inhalation Powders L, W, M Case 3c Case 5s Case 1d Injections, Injectable Suspensionsb L, S, M, G Case 1c Case 2s Case 2d Sterile Powders and Powders for Injection L, M, W Case 2c Case 2s Case 2d Ophthalmic Solutions and Suspensions L, S, M, G Case 1c Case 2s Case 2d Topical Delivery Systems L, S Case 1c Case 3s Case 1d Topical Solutions and Suspensions, and Topical and Lingual Aerosols L, S, M Case 1c Case 3s Case 2d Topical Powders L, M, W Case 3c Case 4s Case 3d Oral Solutions and Suspensions L, S, M Case 1c Case 3s Case 2d Oral Powders L, W Case 2c Case 3s Case 3d Oral Tablets and Oral (Hard and Soft Gelatin) L, W Case 3c Case 4s Case 3d Capsules If there is a special performance function built into the drug product (e.g., counter cap), it a is of importance for any dosage form/route of administration to show that the container closure system performs that function properly. For definition of the term suspension, see footnote a to Table 1. b Explanation of Codes in Table 2: Protection: L (protects from light, if appropriate) S (protects from solvent loss/leakage) M (protects sterile products or those with microbial limits from microbial contamination) W (protects from water vapor, if appropriate) G (protects from reactive gases, if appropriate) Compatibility: Case 1c: Liquid-based dosage form that conceivably could interact with its container closure system components (see examples described in section III.B.1). Case 2c: Solid dosage form until reconstituted; greatest chance for interacting with its container closure system components occurs after it is reconstituted. Case 3c: Solid dosage form with low likelihood of interacting with its container closure system components. Safety: Case 1s: Typically provided are USP Biological Reactivity Test data, extraction/toxicological evaluation, limits on extractables, and batch-to-batch monitoring of extractables. Case 2s: Typically provided are USP Biological Reactivity Test data and possibly extraction/toxicological evaluation. Case 3s: Typically, an appropriate reference to the indirect food additive regulations is sufficient for drug products with aqueous- based solvents. Drug products with non-aqueous based solvent systems or aqueous based systems containing co-solvents generally require additional suitability information (see section III.F). Case 4s: Typically, an appropriate reference to the indirect food additive regulations is sufficient. Case 5s: Typically, an appropriate reference to the indirect food additive regulations for all components except the mouthpiece for which USP Biological Reactivity Test data is provided. Performance: Case 1d: Frequently a consideration. Case 2d: May be a consideration. Case 3d: Rarely a consideration. 2. Quality Control of Packaging Components In addition to providing data to show that a proposed container closure system is suitable for its intended use, an application should also describe the quality control measures that will be used to ensure consistency in the packaging components (see section III.C.3). These controls are intended to limit unintended postapproval These are substances not previously determined to be safe by extraction/toxicological evaluation studies (e.g., the USP Biological Reactivity Tests or another appropriate method conducted on the packaging component as part of the qualifying process). variations in the manufacturing procedures or materials of construction for a packaging component and to prevent adverse affects on the quality of a dosage form. Principal consideration is usually given to consistency in physical characteristics and chemical composition. a. Physical Characteristics The physical characteristics of interest include dimensional criteria (e.g., shape, neck finish, wall thickness, design tolerances), physical parameters critical to the consistent manufacture of a packaging component (e.g., unit weight), and performance characteristics (e.g., metering valve delivery volume, or the ease of movement of syringe plungers). Unintended variations in dimensional parameters, if undetected, may affect package permeability, drug delivery performance, or the adequacy of the seal between the container and the closure. Variation in any physical parameter is considered important if it can affect the quality of a dosage form. b. Chemical Composition The chemical composition of the materials of construction may affect the safety of a packaging component. New materials may result in new substances being extracted into the dosage form or a change in the amount of known extractables. Chemical composition may also affect the compatibility, functional characteristics or protective properties of packaging components by changing rheological or other physical properties (e.g., elasticity, resistance to solvents, or gas permeability). A composition change may occur as a result of a change in formulation or in a processing aid (e.g., using a different mold release agent) or through the use of a new supplier of a raw material. A change in the supplier of a polymeric material or a substance of biological origin is more likely to bring with it an unexpected composition change than a change in the supplier of a pure chemical compound, because polymeric and natural materials are often complex mixtures. A composition change may also occur with a change in the manufacturing process, such as the use of different operating conditions (e.g., a significantly different curing temperature), different equipment, or both. A change in formulation is considered a change in the specifications for the packaging component. This change in the formulation of a packaging component by its manufacturer should be reported to the firm that purchases that component and to any appropriate DMF. The firm that purchases the component should, in turn, report the change to its application as required under 21 CFR 314.70(a) or 601.12. Manufacturers who supply a raw material or an intermediate packaging component should inform their customers of any intended changes to formulations or manufacturing procedures and update the DMF in advance of implementing such a change. Changes which seem innocuous may have unintended consequences on the dosage form marketed in the affected packaging system. The use of stability studies for monitoring the consistency of a container closure system in terms of compatibility with the dosage form and the degree of protection provided to the dosage form is accepted. Currently there is no general policy concerning the monitoring of a packaging system and components with regard to safety. One exception involves inhalation drug products for which batch-to-batch monitoring of the extraction profile for the polymeric and elastomeric components is routine. 3. Associated Components Associated components are packaging components that are typically intended to deliver the dosage form to the patient but are not stored in contact with the dosage form for its entire shelf life. These components are packaged separately in the market package and are either attached to the container upon opening or used only when a dose is to be administered. Measuring spoons, dosing cups, measuring syringes, and vaginal delivery tubes are examples of associated components that typically contact the dosage form only during administration. A hand pump or dropper combined into a closure are examples of an associated component that would contact the dosage form from the time the packaging system is opened until the dosing regimen is completed. The complete and assembled component and its parts should meet suitability criteria appropriate for the drug product and the actual use of the component (see sections III.B.1 and III.B.2). Safety and functionality are the most common factors to be established for suitability. The length of time that the associated component and the dosage form are in direct contact should also be taken into consideration when assessing the suitability of an associated component. 4. Secondary Packaging Components Unlike primary and associated packaging components, secondary packaging components are not intended to make contact with the dosage form. Examples are cartons, which are generally constructed of paper or plastic, and overwraps, which may be fabricated from a single layer of plastic or from a laminate made of metal foil, plastic, and/or paper. A secondary packaging component generally serves one or more of the following additional functions: a. Provides protection from excessive transmission of moisture or solvents into or out of the packaging system b. Provides protection from excessive transmission of reactive gases (atmospheric oxygen, inert headspace filler gas, or other organic vapors) into or out of the packaging system c. Provides light protection for the packaging system d. Provides protection for a packaging system that is flexible or needs extra protection from rough handling e. Provides an additional measure of microbiological protection (i.e., by maintaining sterility or by protecting the packaging system from microbial intrusion) When information on a container closure system is submitted in an application, the emphasis would normally be on the primary packaging components. For a secondary packaging component, a brief description will usually suffice unless the component is intended to provide some additional measure of protection to the drug product. In this case, more complete information should be provided, along with data showing that the secondary packaging component actually provides the additional protection (see sections III.B.1 and III.B.2). Because secondary packaging components are not intended to make contact with the dosage form, there is usually less concern regarding the materials from which they are constructed. However, if the packaging system is relatively permeable, the possibility increases that the dosage form could be contaminated by the migration of an ink or adhesive component, or from a volatile substance present in the secondary packaging component. (For example, a solution packaged in a LDPE container was found to be contaminated by a volatile constituent of the secondary packaging components that enclosed it.). In such a case, the secondary packaging component should be considered a potential source of contamination and the safety of its materials of construction should be taken into consideration. See Table 3 for additional information. This section applies to primary packaging components and to those associated and secondary packaging components that provide protection to the drug product or for which there may be a safety concern (see section III.B). Where possible, this information should be included in the application. Alternatively, it may be provided in a drug master file (see section V) and a letter of authorization (LOA) to the DMF submitted in the application. The LOA permits the Agency to review the information in support of a particular application. For further information see the FDA guidance for industry Submission of Documentation for the Sterilization Process Validation in Applications of Human and Veterinary Drug Products (November 1994). C. Information That Should Be Submitted in Support of an Original Application for Any Drug Product15 Additional discussion and information regarding the CMC information to be provided in an application (NDA, ANDA, or BLA) can be found in the guidances and guidelines listed in Attachment E. 1. Description A general description of the entire container closure system should be provided in the CMC section of the application. In addition, the following information should be provided by the applicant for each individual component of the packaging system: a. Identification by product name, product code (if available), the name and address of the manufacturer, and a physical description of the packaging component (e.g., type, size, shape, and color) b. Identification of the materials of construction (i.e., plastics, paper, metal, glass, elastomers, coatings, adhesives, and other such materials) should be identified by a specific product designation (code name and/or code number) and the source (name of the manufacturer). Alternate materials of construction should also be indicated. Postconsumer recycled plastic should not be used in the manufacture of a primary packaging component. If used for a secondary or associated component, then the safety and compatibility of the material for its intended use should be addressed appropriately. c. Description of any operations or preparations that are performed on a packaging component by the applicant (such as washing, coating, sterilization, or depyrogenation)17 2. Information About Suitability a. To establish safety and to ensure consistency, the complete chemical composition should be provided for every material used in the manufacture of a packaging component. b. Test results from appropriate qualification and characterization tests should be provided. Adequate information regarding the tests, methods, acceptance criteria, reference standards, and validation information should be provided. To address protection, use of USP tests (see Attachment A) for light transmission, moisture permeation, microbial limits, and sterility are generally considered sufficient. Testing for properties other than those described in USP (e.g., gas transmission, solvent leakage container integrity) may also be necessary. To address safety and compatibility, the results of extraction/toxicological evaluation studies should be provided for drug products that are likely to interact with the packaging components and introduce extracted substances into the patient (see Table 1). For drug products less likely to interact, other tests (e.g., USP Biological Reactivity Test) or information (e.g., appropriate reference to the indirect food additive regulations at 21 CFR 174-186) could be used to address the issue of safety and compatibility (see Table 2). For example, an appropriate reference to an indirect food additive regulation is generally sufficient for a solid oral dosage form product. To address performance, the results of USP and non-USP functionality tests are considered sufficient if the test and acceptance criteria are appropriate for the intended purpose. Tests described in the USP are typically considered sufficient standards for establishing specified properties and characteristics of specified materials of construction or packaging components. For non-USP tests, an applicant should provide justification for the use of the test, a complete and detailed description of how the test was performed, and an explanation of what the test is intended to establish. If a related USP test is available, comparative data should be provided using both methods. Supporting data should include a demonstration of the suitability of the test for its intended use and its validation. Testing on an assembled container closure system is usually performed by the applicant (or a testing laboratory commissioned by the applicant) and the test results provided in the application. Such tests may include vacuum leak testing, moisture permeation, and weight loss or media fill. Testing on an individual packaging component is typically performed by the manufacturer of the component and reported via a DMF (see section V). 3. Information About Quality Control The fabricator/manufacturer of a packaging component and the drug product manufacturer who uses this firm share the responsibility for ensuring the quality of packaging components. These firms should have a quality control program in place so that consistent components are produced. The drug product manufacturer must have an inspection program for incoming packaging components and materials (21 CFR 211.22, 211.84 and 211.122). For most drug products, a drug product manufacturer may accept a packaging component lot based on receiving a Certificate of Analysis (COA) or Certificate of Certification (COC) from the component supplier and the performance of an appropriate identification test, provided the supplier’s test data are periodically validated (21 CFR 211.84(d)(3)). Acceptance of a packaging component lot based on a supplier's COA or COC may not be appropriate in all cases (e.g., some packaging components for certain inhalation drug products). a. Applicants The tests and methods used by the applicant for acceptance of each batch of a packaging component that they receive should be described. If a batch is to be accepted based on a supplier's COA or COC, then the procedure for supplier validation should be described. The data from the supplier’s COA or COC should clearly indicate that the lot meets the applicant’s acceptance criteria. Acceptance criteria for extractables should also be included, if appropriate. Dimensional and performance criteria should be provided. Dimensional information is frequently provided via a detailed schematic drawing complete with target dimensions and tolerances and may be provided via the packaging component manufacturer's DMF. A separate drawing may not be necessary if the packaging component is part of a larger unit for which a drawing is provided or if the component is uncomplicated in design (e.g., a cap liner). b. Manufacturers of Packaging Components Sold to Drug Product Statistical process control is defined as "[t]he application of statistical techniques for measuring and analyzing the variation in processes." Juran, J.M., ed., 1988, Quality Control Handbook, 4th ed., McGraw-Hill, p. 24.2. Manufacturers Each manufacturer of a packaging component sold to a drug product manufacturer should provide a description of the quality control measures used to maintain consistency in the physical and chemical characteristics of the component. These generally include release criteria (and test methods, if appropriate) and a description of the manufacturing procedure. If the release of the packaging component is based on statistical process control, a complete description of the process (including control criteria) and its validation should be provided. The description of the manufacturing process is generally brief and should include any operations performed on the packaging component after manufacture but prior to shipping (e.g., washing, coating, and/or sterilization). In some cases it may be desirable for the description to be more detailed and to include in-process controls. This information may be provided via a DMF (see section V). c. Manufacturers of Materials of Construction or of Packaging Components Used to Make Other Packaging Components The quality control procedures of the manufacturer of a packaging component may sometimes rely in whole or in part on the quality control procedures of a manufacturer who makes an intermediate packaging component that is used to create the component. If so, each contributor to the final packaging system should provide a description of the quality control measures used to maintain consistency in the physical and chemical characteristics of the separate components and of the assembled packaging system that they provide. The manufacturer of each material of construction should be prepared to describe the quality control measures used to maintain consistency in the chemical characteristics of their product. This information may be provided via a DMF (see section V). 4. Stability Data (Packaging Concerns) Stability testing of the drug product should be conducted using the container closure systems proposed in the application. The packaging system used in each stability study should be clearly identified. The container closure system should be monitored for signs of instability. When appropriate, an evaluation of the packaging system should be included in the stability protocol. Even when a formal test for quality of the packaging system is not performed, the applicant should investigate any observed change in the packaging system used in the stability studies. The observations, results of the investigation, and corrective actions should be included in the stability report. If the corrective action requires a change in an approved container closure system, a supplemental application should be submitted. For general guidance on conducting stability studies, refer to the FDA Guideline for Submitting Documentation for the Stability of Human Drugs and Biologics (February 1987). The stability guideline is undergoing revision and will be superseded by the FDA’s draft guidance for industry Stability Testing of Drug Substance and Drug Products (June 1998), once it is issued in final form. Table 3 Information That Should Be Submitted in an Original Application for Any Drug Product Description Overall general description of the container closure system, plus: For Each Packaging Component: C Name, product code, manufacturer, physical description C Materials of construction (for each: name, manufacturer, product code) C Description of any additional treatments or preparations Suitability Protection: (By each component and/or the container closure system, as appropriate) C Light exposure C Reactive gases (e.g., oxygen) C Moisture permeation C Solvent loss or leakage C Microbial contamination(sterility/container integrity, increased bioburden, microbial limits) C Filth C Other Safety: (for each material of construction, as appropriate) C Chemical composition of all plastics, elastomers, adhesives, etc.a C Extractables, as appropriate for the materialb Extraction/toxicological evaluation studies, as appropriate Appropriate USP testing Appropriate reference to the indirect food additive regulations (21 CFR 174-186) C Other studies as appropriate Compatibility: (for each component and/or the packaging system, as appropriate) C Component/dosage form interaction, USP methods are typically accepted C May also be addressed in post-approval stability studies Performance: (for the assembled packaging system) C Functionality and/or drug delivery, as appropriate Quality Control For Each Packaging Component Received by the Applicant: C Applicant's tests and acceptance criteriac C Dimensional (drawing) and performance criteria C Method to monitor consistency in composition, as appropriate For Each Packaging Component Provided by the Supplier: C Manufacturer's acceptance criteria for release, as appropriate C Brief description of the manufacturing process Stability C See section III.C.4 Including any additives used in the manufacture of a packaging component a See Attachment C for further discussion of extraction studies. Testing of plastics should be performed on the b packaging component, not on the unformed resin. For a blow/fill/seal product, extractables should be evaluated on the formed drug product container itself. This also applies to a container closure system which is manufactured as part of the drug product manufacturing process. Note that an applicant's acceptance tests may include, among others, test parameters indicated under the description, c suitability, and quality control sections of this table. The terms SVP and LVP as used in this guidance correspond to the definitions of small-volume injection and large- volume injection, respectively, in USP 23, page 1650. D. Inhalation Drug Products Inhalation drug products include inhalation aerosols (metered dose inhalers); inhalation solutions, suspensions, and sprays (administered via nebulizers); inhalation powders (dry powder inhalers); and nasal sprays. The CMC and preclinical considerations for inhalation drug products are unique in that these drug products are intended for respiratory-tract compromised patients. This is reflected in the level of concern given to the nature of the packaging components that may come in contact with the dosage form or the patient (see Table 1). Guidance regarding the container closure system information to support the approval of applications for inhalation drug products will be provided in two guidance documents when finalized: the guidance for industry Metered Dose Inhaler (MDI) and Dry Powder Inhaler (DPI) Drug Products; Chemistry, Manufacturing and Controls Documentation (a draft was issued in October 1998) and the guidance for industry Nasal Spray and Inhalation Solution, Suspension, and Spray Drug Products; Chemistry, Manufacturing and Controls Documentation, which is currently under development. E. Drug Products for Injection and Ophthalmic Drug Products These dosage forms share the common attributes that they are generally solutions, emulsions, or suspensions, and are all required to be sterile. Injectable dosage forms represent one of the highest risk drug products (see Table 1). Any contaminants present (as a result of contact with a packaging component or due to the packaging system’s failure to provide adequate protection) can be rapidly and completely introduced into the patient's general circulation. Although the risk factors associated with ophthalmics are generally considered to be lower than for injectables, any potential for causing harm to the eyes demands caution. 1. Injectable Drug Products Injectable drug products may be liquids in the form of solutions, emulsions, suspensions, or dry solids that are to be combined with an appropriate vehicle to yield a solution or suspension. Injections are classified as small-volume parenterals (SVPs), if they have a solution volume of 100 mL or less, or as large-volume parenterals (LVPs), if the solution volume exceeds 100 mL. For solids that must be dissolved or dispersed in an appropriate diluent before being injected, the diluent may be in the same container closure system (e.g., a two-part vial) or be part of the same market package (e.g., a kit containing a vial of diluent). An SVP may be packaged in a disposable cartridge, a disposable syringe, a vial, an ampule or a flexible bag. An LVP may be packaged in a vial, a flexible bag, a glass bottle or, in some cases, as a disposable syringe. Cartridges, syringes, vials, and ampules are usually composed of Type I or II glass, or polypropylene. Flexible bags are typically constructed with multilayered plastic. Stoppers and septa in cartridges, syringes, and vials are typically composed of elastomeric materials. The input (medication) and output (administration) ports for flexible bags may be plastic and/or elastomeric materials. An overwrap may be used with flexible bags to retard solvent loss and to protect the flexible packaging system from rough handling. The potential effects of packaging component/dosage form interactions are numerous. Hemolytic effects may result from a decrease in tonicity and pyrogenic effects may result from the presence of impurities. The potency of the drug product or concentration of the antimicrobial preservatives may decrease due to adsorption or absorption. A cosolvent system essential to the solubilization of a poorly soluble drug can also serve as a potent extractant of plastic additives. A disposable syringe may be made of plastic, glass, rubber, and metal components, and such multicomponent construction provides a potential for interaction that is greater than when a container consists of a single material. Injectable drug products require protection from microbial contamination (loss of sterility or added bioburden) and may also need to be protected from light or exposure to gases (e.g., oxygen). Liquid-based injectables may need to be protected from solvent loss, while sterile powders or powders for injection may need to be protected from exposure to water vapor. For elastomeric components, data showing that a component meets the requirements of USP Elastomeric Closures for Injections will typically be considered sufficient evidence of safety. For plastic components, data from USP Biological Reactivity Tests will typically be considered sufficient evidence of safety. Whenever possible, the extraction studies should be performed using the drug product. If the extraction properties of the drug product vehicle may reasonably be expected to differ from that of water (e.g., due to high or low pH or due to a solubilizing accipient), then drug product should be used as the extracting medium. If the drug substance significantly affects extraction characteristics, it may be necessary to perform the extractions using the drug product vehicle. If the total of extracts significantly exceeds the amount obtained from water extraction, then an extraction profile should be obtained. It may be advisable to obtain a quantitative extraction profile of an elastomeric or plastic packaging component and to compare this periodically to the profile from a new batch of the packaging component. Extractables should be identified whenever possible. For a glass packaging component, data from USP Containers: Chemical Resistance — Glass Containers will typically be considered sufficient evidence of safety and compatibility. In some cases (e.g., for some chelating agents), a glass packaging component may need to meet additional criteria to ensure the absence of significant interactions between the packaging component and the dosage form. Performance of a syringe is usually addressed by establishing the force to initiate and maintain plunger movement down the barrel, and the capability of the syringe to deliver the labeled amount of the drug product. 2. Ophthalmic Drug Products These drug products are usually solutions marketed in a LDPE bottle with a dropper built into the neck (sometimes referred to as droptainer), or ointments marketed in a metal tube with an ophthalmic tip (see section III.F.2 for a more detailed discussion of tubes). A few solution products use a glass container due to stability concerns regarding plastic packaging components. Ophthalmic ointments that are reactive toward metal may be packaged in a tube lined with an epoxy or vinyl plastic coating. A large volume intraocular solution (for irrigation) may be packaged in a glass or polyolefin (polyethylene and/or polypropylene) container. The American Academy of Ophthalmology (AAO) recommended to the Agency that a uniform color coding system be established for the caps and labels of all topical ocular medications. An applicant should either follow this system or provide an adequate justification for any deviations from the system. The AAO color codes, as revised and approved by the AAO Board of Trustees in June 1996, are shown in Table 5. Although ophthalmic drug products can be considered topical products (section III.F.2), they have been grouped here with injectables because they are required to be sterile (21 CFR 200.50(a)(2)) and the descriptive, suitability, and quality control information is typically the same as that for an injectable drug product. Since ophthalmic drug products are applied to the eye, compatibility and safety should also address the container closure system's potential to form substances which irritate the eye or introduce particulate matter into the product (see USP <771> Ophthalmic Ointments). See Table 4 for additional information. Table 4 Information That Typically Should Be Submitted for Injectable or Ophthalmic Drug Products Description Overall general description of container closure system, plus: For Each Packaging Component: C Name, product code, manufacturer, physical description C Materials of construction (for each: name, manufacturer and product code) C Description of any additional treatments (e.g., procedures for sterilizing and depyrogenating packaging components) Suitability Protection: (By each component and/or the container closure system, as appropriate) C Light exposure, when appropriate C Reactive gases (e.g., oxygen) C Moisture permeation (powders) C Solvent loss (liquid-based dosage forms) C Sterility (container integrity) or increased bioburden C Seal integrity or leak testing of tubes (ophthalmics) Safety: (for each material of construction, as appropriate) C Chemical composition of all plastics, elastomers, adhesives, etc.a C For elastomeric closures: USP Elastomeric Closures for Injections testing C For glass components: USP Containers: Chemical Resistance — Glass Containers C For plastic components and coatings for metal tubes: USP Biological Reactivity Tests C If the extraction properties of the drug product vehicle may reasonably be expected to differ from that of water (e.g., due to high or low pH or due to a solubilizing excipient), then drug product should be used as the extracting medium. C If the total weight of extracts significantly exceeds the amount obtained from water extraction, then an extraction profile should be obtained. C For plastic or elastomeric components undergoing heat sterilization, it is current practice to request that the extraction profile be obtained at 121EC/1 hour using an appropriate solvent. Compatibility: (for each component and/or the packaging system, as appropriate) C For coatings on metal tubes: Coating integrity testing C For elastomeric components: Evaluation of swelling effects C For plastic components (including tube coatings): USP Containers: Physicochemical Tests - Plastics testing C For ophthalmics: Particulate matter and eye irritants C Stability studies also support compatibility Performance: (For the assembled packaging system) C Functionality and/or drug delivery Quality Control For Each Packaging System Received by the Applicant: C Applicant’s tests and acceptance criteriac C Dimensional (drawing) and performance criteria C Method to monitor consistency in composition of most plastic and elastomeric components (e.g., periodic comparison to the original extraction profile is recommended) For Each Packaging Component Provided by the Supplier: C Manufacturer’s acceptance criteria for release, as appropriate C Description of the manufacturing process, as appropriate (e.g., procedure/validation for sterilization and depyrogenation) Stability C See section III.C.4 Including any additives used in the manufacture of a packaging component a. Testing for plastics should be performed on the packaging component, not on the unformed resin. b. Note that applicant's acceptance tests may include, among others, test parameters indicated under the c. description, suitability, and quality control sections of this table. Refer to the Guidance for Industry for the Submission of Documentation for Sterilization Process Validation d in Applications for Human and Veterinary Drug (November 1994). Table 5 AAO Recommended Color Coding of Caps and Labels for Topical Ophthalmic Medications Class Color Pantone® Number Anti-Infectives Tan Anti-Inflammatories/Steroids Pink 197, 212 Mydriatics and Cycloplegics Red 485C Nonsteroidal Anti-Inflammatories Gray 4C Miotics Green 374, 362, 348 Beta-Blockers Yellow or Blue 290, 281 a Yellow C Adrenergic Agonists (e.g., Propine) Purple 2583 Carbonic Anhydrase Inhibitors Orange 1585 Prostaglandin Analogues Turquoise 326C The AAO notes that as new classes of drugs are developed this coding system may be modified in the future by a reassigning the blue color to a new class of drugs while keeping yellow for beta-blockers. F. Liquid-Based Oral and Topical Drug Products and Topical Delivery Systems A wide variety of drug products fall into this category. The presence of a liquid phase implies a significant potential for the transfer of materials from a packaging component into the dosage form. The higher viscosity of semisolid dosage forms and transdermal systems may cause the rate of migration of leachable substances into these dosage forms See Attachment A for a listing of the FDA regulations for indirect food additives. to be slower than for aqueous solutions. Due to extended contact, the amount of leachables in these drug products may depend more on a leachable material’s affinity for the liquid/semisolid phase than on the rate of migration. 1. Liquid-Based Oral Drug Products Typical liquid-based oral dosage forms are elixirs, emulsions, extracts, fluid extracts, solutions, gels, syrups, spirits, tinctures, aromatic waters, and suspensions. These products are usually nonsterile but may be monitored for changes in bioburden or for the presence of specific microbes. These dosage forms are generally marketed in multiple-unit bottles or in unit-dose or single-use pouches or cups. The dosage form may be used as is or admixed first with a compatible diluent or dispersant. A bottle is usually glass or plastic, often with a screw cap with a liner, and possibly with a tamper-resistant seal or an overcap that is welded to the bottle. The same cap liners and inner seals are sometimes used with solid oral dosage forms. A pouch may be a single-layer plastic or a laminated material. Both bottles and pouches may use an overwrap, which is usually a laminated material. A single-dose cup may be metal or plastic with a heat-sealed lid made of a laminated material. A liquid-based oral drug product typically needs to be protected from solvent loss, microbial contamination, and sometimes from exposure to light or reactive gases (e.g., oxygen). For glass components, data showing that a component meets the requirements of USP Containers: Glass Containers are accepted as sufficient evidence of safety and compatibility. For LDPE components, data from USP Containers tests are typically considered sufficient evidence of compatibility. The USP General Chapters do not specifically address safety for polyethylene (HDPE or LDPE), polypropylene (PP), or laminate components. A patient's exposure to substances extracted from a plastic packaging component (e.g., HDPE, LDPE, PP, laminated components) into a liquid-based oral dosage form is expected to be comparable to a patient's exposure to the same substances through the use of the same material when used to package food. Based on this assumption, an appropriate reference to the indirect food additive regulations (21 CFR 174-186) is typically considered sufficient to establish safety of the material of construction, provided any limitations specified in the regulations are taken into consideration. This assumption is considered valid for liquid-based oral dosage forms which the patient will take only for a relatively short time (acute dosing regimen). See Attachment C for a discussion of extraction studies. For liquid-based oral drug products which the patient will continue to take for an extended period (i.e., months or years (chronic drug regimen)), a material of construction that meets the requirements for indirect food additives will be considered safe — on that basis alone — only if the patient's exposure to extractables can be expected to be no greater than the exposure through foods, or the length of exposure is supported by toxicological information. For example, if the dosage form is aqueous-based and contains little or no cosolvent (or other substance, including the active drug substance, liable to cause greater extraction of substances from plastic packaging components than would be extracted by water), meeting the requirements of the indirect food additive regulations will usually satisfy the issue of safety. If the dosage form contains cosolvents (or if, for any reason, it may be expected to extract greater amounts of substances from plastic packaging components than water), then additional extractable information may be needed to address safety issues. Performance is typically not a factor for liquid-based oral drug products. See Table 6 for additional information. 2. Topical Drug Products Topical dosage forms include aerosols, creams, emulsions, gels, lotions, ointments, pastes, powders, solutions, and suspensions. These dosage forms are generally intended for local (not systemic) effect and are generally applied to the skin or oral mucosal surfaces. Topical products also include some nasal and otic preparations as well as some ophthalmic drug products. Ophthalmic drug products are discussed in section III.E.2. Vaginal and rectal drug products may be considered to be topical if they are intended to have a local effect. Some topical drug products are sterile or may be subject to microbial limits. In these cases, additional evaluation may be necessary when determining the appropriate packaging. A liquid-based topical product typically has a fluid or semi-solid consistency and is marketed in a single- or multiple-unit container (e.g., a rigid bottle or jar, a collapsible tube, or a flexible pouch). A powder product may be marketed in a sifter-top container. An antibacterial product may be marketed as part of a sterile dressing. There are also a number of products marketed as a pressurized aerosol or a hand-pumped spray. A rigid bottle or jar is usually made of glass or polypropylene with a screw cap. The same cap liners and inner seals are sometimes used as with solid oral dosage forms. A collapsible tube is usually constructed from metal or is metal-lined, from LDPE or from a laminated material. Tubes are identified as either blind-end or open-end. In the former, there is no product contact with the cap on storage. Usually, the size of the tube is controlled by trimming it to an appropriate length for the target fill volume. Fill volume is commonly determined as an in-process measurement using bulk density. Usually there is no cap liner, although the tube may have a liner. Aluminum tubes usually include a liner. A tube liner is frequently a lacquer or shellac whose composition should be stated. A tube is closed by folding or crimping the open end. The type of fold (roll or saddle) should be described, as well as the type and composition of any sealant. If the tube material is self-sealing through the application of heat alone, this should be stated. If the market package includes a separate applicator device, this should be described. Product contact is possible if the applicator is part of the closure, and therefore an applicator's compatibility with the drug product should be established, as appropriate. Dressings consist of dosage form on a bandage material (e.g., Absorbent Gauze USP or Gauze Bandage USP) within a flexible pouch. The pouch should maintain the sterility and physical stability of the dressing. Unlike inhalation aerosols, topical aerosols are not intended to be inhaled. The droplet size of the spray does not need to be carefully controlled, nor is the dose usually metered. The spray may be used to apply dosage form to the skin (topical aerosol) or mouth (lingual aerosol) and functionality of the sprayer should be addressed. A topical aerosol may be sterile or may conform to acceptance criteria for microbial limits. The packaging system for a liquid-based topical product should deter solvent loss and should provide protection from light when appropriate. Because these dosage forms may be placed in contact with mucosal membranes or with skin that has been broken or otherwise compromised, the safety of the materials of construction for the packaging components should be evaluated. For liquid and semisolid dosage forms, the same information as described in section III.F.1 is accepted for establishing safety and compatibility. For solid dosage forms, an appropriate reference to the indirect food additive regulations is typically considered sufficient to establish safety. See Table 6 for additional information. 3. Topical Delivery Systems Topical delivery systems are self-contained, discrete dosage forms that are designed to deliver drug via intact skin or body surface. USP Pharmaceutical Dosage Forms defines three types of topical delivery systems: transdermal, ocular, and intrauterine. Transdermal systems are usually applied to the skin with an adhesive and may be in place for an extended period. Ocular systems are inserted under the lower eyelid, typically for seven days. Intrauterine systems are held in place without adhesive and may stay in place for a year. A transdermal system is usually comprised of an outer barrier, a drug reservoir (with or without a rate-controlling membrane), a contact adhesive, and a protective liner. An ocular system usually consists of the drug formulation contained in a rate-controlling membrane. An intrauterine system may be constructed of a plastic material impregnated with active ingredients or a coated metal. It is shaped to remain in place after being inserted in the uterus. Each of these systems is generally marketed in a single-unit soft blister pack or a preformed tray with a preformed cover or overwrap. Compatibility and safety for topical delivery systems are addressed in the same manner as for topical drug products. Performance and quality control should be addressed for the rate-controlling membrane. Appropriate microbial limits should be established and justified for each delivery system. Microbiological standards are under development; therefore the review division for a specific application should be consulted. See Table 6 for additional information. Table 6 Information That Typically Should Be Submitted for Liquid-Based Oral and Topical Drug Products and for Topical Drug Delivery Systems Description Overall general description of container closure system, plus: For Each Packaging Component: C Name, product code, manufacturer, physical description C Materials of construction (for each: name, manufacturer and product code) C Description of any additional treatments (e.g., procedure for washing components) Suitability Protection: (by each component and/or the container closure system, as appropriate) C Light exposure C Reactive gases (e.g., oxygen) C Solvent loss C Moisture permeation (liquid-based oral products would typically meet USP requirements for a tight or class A container) C Microbial contamination (container integrity, increased bioburden, microbial limits, as appropriate) C Seal integrity or leak testing of tubes (topical drug products) and unit dose containers (liquid-based oral drug products) Safety: (for each material of composition, as appropriate) C Chemical composition of all plastics, elastomers, adhesives, etc.a C For most liquid-based oral drug products: appropriate reference to the indirect food additive regulations C For liquid-based oral drug products with chronic dosing regimens that contain alcohol or a cosolvent: information to establish that exposure to extractables will be no greater than that expected to result from the use of similar packaging components when used with foods, or that the exposure is acceptable based on b toxicological data. C For topical drug products (plastic coatings for metal tubes), and plastic drug delivery system components: USP Containers testing C For topical delivery systems: appropriate reference to indirect food additive regulations Compatibility: (for each component of the packaging system, as appropriate) C For LDPE and glass components, USP Containers testingc C For coatings for metal tubes: coating integrity testing Performance: (for the assembled packaging system) C Functionality and/or drug delivery should be addressed, as appropriate. Quality Control For Each Packaging Component Received by the Applicant: C Applicant's tests and acceptance criteriad C Dimensional (drawing) and performance criteria C Method to monitor consistency in composition, as appropriate For Each Packaging Component Provided by the Supplier: C Manufacturer's acceptance criteria for release, as appropriate C Description of the manufacturing process, as appropriate Stability C See section III.C.4 Including any additives used in the manufacture of a packaging component a The materials of construction should be acceptable for contact with foods that have extraction characteristics similar b to those of the drug product (e.g., aqueous, acidic, alcoholic, or fatty). Plastics testing should be performed on the packaging component, not on the unformed resin. c Note that applicant's acceptance tests may include, among others, test parameters indicated under the description, d suitability, and quality control sections of this table. G. Solid Oral Dosage Forms and Powders for Reconstitution The most common solid oral dosage forms are capsules and tablets. For the purpose of this guidance, oral powders and granules for reconstitution are also included in this group. The risk of interaction between packaging components and a solid oral dosage form is generally recognized to be small. Powders that are reconstituted in their market container, however, have an additional possibility of an interaction between the packaging components and the reconstituting fluid. Although the contact time will be relatively short when compared to the component/dosage form contact time for liquid-based oral dosage forms, it should still be taken into consideration when the compatibility and safety of the container closure system is being evaluated. A typical container closure system is a plastic (usually HDPE) bottle with a screw-on or snap-off closure and a flexible packaging system, such as a pouch or a blister package. A typical closure consists of a cap, often with a liner, and frequently with an inner seal. If used, fillers, desiccants, and other absorbent materials are considered primary packaging components. The most common forms of flexible packaging are the blister package and the pouch. A blister package usually consists of a lidding material and a forming film. The lidding material is usually a laminate which includes a barrier layer (e.g., aluminum foil) with a print primer on one side and a sealing agent (e.g., a heat-sealing lacquer) on the other side. The sealing agent contacts the dosage form and the forming film. The forming film may be a single film, a coated film, or a laminate. A pouch typically consists of film or laminate which is sealed at the edges by heat or adhesive. Leak testing is usually performed on flexible packages as part of the in-process controls. Solid oral dosage forms generally need to be protected from the potential adverse affects of water vapor. Protection from light and reactive gases may also be needed. For example the presence of moisture may affect the decomposition rate of the active drug substance or the dissolution rate of the dosage form. The container should have an intrinsically low rate of water vapor permeation, and the container closure system should establish a seal to protect the drug product. Three standard tests for water vapor permeation have been established by the USP for use with solid oral dosage forms. Hartauer, K.J. et al., "The Effects of Rayon Coiler on the Dissolution Stability of Hard Shelled Gelatin Capsules," Pharmaceutical Technology, 17:76-83 (1993). 1. Polyethylene Containers (USP <661>): This test is conducted on containers heat-sealed with foil laminate; therefore only the properties of the container are evaluated. The level of protection from water vapor permeation provided by a packaging system marketed with a heat-sealed foil laminate inner seal (up to the time the inner seal is removed) is expected to be approximately the same as that determined by this test. The acceptance criteria are those established in USP <671>. 2. Single-Unit Containers and Unit-Dose Containers for Capsules and Tablets (USP <671>): This test measures the water vapor permeation of a single- unit or unit-dose container closure system and establishes acceptance criteria for five standards (Class A-E containers). 3. Multiple-Unit Containers for Capsules and Tablets (USP <671>): This test is intended for drugs being dispensed on prescription, but has also been applied to the drug product manufacturer’s container closure system. If the container closure system has an inner seal, it should be removed prior to testing. The results from this study reflect the contributions to water vapor permeation through the container, and through the seal between the container and the closure. Acceptance criteria have been established for two standards (tight and well-closed containers). For solid oral dosage forms, a reference to the appropriate indirect food additive regulation for each material of construction is typically considered sufficient evidence of safety. However, for a powder for reconstitution dosage form, reference only to the indirect food additive regulations as evidence of safety for the materials of construction is not recommended. Compatibility for solid oral dosage forms and for powders for reconstitution is typically addressed for plastics and glass by meeting the requirements of the USP Containers test. The USP monographs for Purified Cotton and Purified Rayon will typically be considered sufficient standards to establish the safety of these materials as fillers in the packaging of tablets or capsules, with the following caveats: cotton need not meet the monograph requirements for sterility, fiber length, or absorbency; and rayon need not meet the monograph requirements for fiber length or absorbency. Appropriate tests and acceptance criteria for identification and for moisture content should be provided for both cotton and rayon filler. Rayon has been found to be a potential source of dissolution problems for gelatin capsules and gelatin-coated tablets and this characteristic should be considered when choosing a filler. The use of other fillers may be considered with appropriate tests and acceptance criteria. If a desiccant or other absorbent material is used, the composition should be provided (or an appropriate DMF referenced). The component should differ in shape and/or size from the tablets or capsules with which it is packaged. This will help distinguish between the component and the dosage form. Because these are considered primary packaging components, appropriate tests and acceptance criteria to establish suitability should be provided (see Table 7 for additional information). Table 7 Information That Typically Should Be Submitted for Solid Oral Drug Products and Powders Description Overall general description of container closure system, plus: For Each Packaging Component: C Name, product code, manufacturer C Materials of construction C Description of any additional treatments Suitability Protection: (by each component and/or the container closure system, as appropriate) C Light exposure C Moisture permeation C Seal integrity or leak tests for unit-dose packaging Safety: (for each material of construction, as appropriate) C Chemical composition of all plastics, elastomers, adhesives, etc.a C For tablets, capsules, and powders, appropriate reference to the indirect food additive regulation may be submitted, but may not be appropriate for Powders for Reconstitution. C For rayon and cotton fillers, data from USP monographs. For non-USP materials, data and acceptance criteria should be provided. C For dessicants and other absorbent materials: the size and shape should differ from that of the dosage form. Compatibility: (on each component or the packaging system) C For glass and plastic containers, data from USP Containers testing. b Performance: (on each component or the packaging system, as appropriate) C Functionality and/or drug delivery, as appropriate Quality Control For Each Packaging Component Received by the Applicant: C Applicant's tests and acceptance criteriac C Dimensional (drawing) and performance criteria C Method to monitor consistency in composition, as appropriate For Each Packaging Component Provided by the Supplier: C Manufacturer's acceptance criteria for release, as appropriate C Description of manufacturing process, as appropriate Stability C See section III.C.4 Including any additives used in the manufacture of a packaging component a Testing of plastics should be performed on the packaging component, not on the unformed resin. b Note that applicant's acceptance tests may include, among others, test parameters indicated under the description, c suitability, and quality control sections of this table. H. Other Dosage Forms The CGMP requirements for container closure systems for compressed medical gases are described in 21 CFR 210 and 211. The containers are regulated by the U.S. Department of Transportation. For more detailed information refer to the CDER Compressed Medical Gas Guideline (February 1989). When submitting information for a drug product or dosage form not specifically covered by the sections above, a firm should take into consideration: (1) the compatibility and safety concerns raised by the route of administration of the drug product and the nature of the dosage form (e.g., solid or liquid-based); (2) the kinds of protection the container closure system should provide to the dosage form; and (3) the potential effect of any treatment or handling that may be unique to the drug product in the packaging system. Quality control procedures for each packaging component should ensure the maintenance of the safety and quality of future production batches of the drug product. IV. POSTAPPROVAL PACKAGING CHANGES For an approved application (NDA, ANDA or BLA), a change to a container closure system, to a component of the container closure system, to a material of construction for a component, or to a process involving one of the above must be reported to the application. The filing requirements are specified under 21 CFR 314.70 (supplements and other changes to an approved application) for an NDA or ANDA, and under 21 CFR 601.12 (changes to an approved application) for a BLA. The submission should address the items described and discussed in sections III.B and III.C of this guidance. The Agency intends to provide additional guidance on postapproval changes in container closure systems in the future. V. TYPE III DRUG MASTER FILES A. General Comments The responsibility for providing information about packaging components rests foremost with the applicant of an NDA, ANDA or BLA, or the sponsor of an IND. This information may be provided to the applicant by the manufacturer of a packaging component or material of construction and may be included directly in the application. Any information that a manufacturer does not wish to share with the applicant or sponsor (i.e., because it is considered proprietary) may be placed in a Type III DMF and incorporated into the application by a letter from the manufacturer to the applicant which authorizes reference to the DMF. The letter of authorization should specify the firm to whom authorization is granted, the component or material of construction being described, and where the information and/or data is located in the file by page number and/or date of submission. This last item is especially important for files that contain information on multiple components or have several volumes. Information in a Type III DMF is not restricted to data of a proprietary nature. DMF holders may include in their files as much or as little information as they choose. In addition, a manufacturer of a packaging component is not required to maintain a Type III DMF. Without a DMF there is no procedure for the Agency to review proprietary information except by submission to the application. The Agency ordinarily reviews a DMF only in connection with an application (IND, NDA, ANDA, or BLA). If the combined information from the application and the DMF is not adequate to support approval of the application or safety for the IND, then the Agency may request additional information from the applicant and/or the DMF holder, as appropriate. In the event of a change in the DMF, the holder of a DMF must notify the holder of each application supported by the DMF (21 CFR 314.420(c)). Notice should be provided well before the change is implemented to allow the applicant or sponsor enough time to file a supplement or an amendment to the affected application. General information on format and content of a DMF and a LOA may be found in the CDER Guideline for Drug Master Files (September 1989). B. Information in a Type III DMF Section III of this guidance describes the kind of descriptive, suitability, and quality control information which the Agency usually reviews concerning packaging components and materials of construction for drug products. The following are examples of the items that have been submitted via a Type III DMF. 1. Descriptive Information: a. General description of the component and the address of the manufacturing site b. Description of the manufacturing process for a packaging component and operations performed after manufacture, but prior to shipment (washing, coating, sterilization or depyrogenation) c. Description of the acceptance, in-process, and release controls for materials of construction, the manufacturing process, and the finished product (component part or assembled component) d. Characterization of the key properties 2. Information About Suitability a. Protection provided by the component b. Safety information on the materials of construction or the finished component c. Compatibility of the materials of construction or the finished component with the specific dosage form, the specific drug product, or equivalent materials 3. Information About Quality Control: a. Dimensional (an engineering drawing) and performance criteria for the component b. A description of the quality control measures used to maintain consistency in the physical and chemical characteristics of packaging components c. A summary of the quality assurance/quality control criteria when release of the component is based on statistical process control VI. BULK CONTAINERS A. Containers for Bulk Drug Substances Drug substances are generally solids, but some are liquids or gases. The container closure system for storage or shipment of a bulk solid drug substance is typically a drum with double LDPE liners that are usually heat sealed or closed with a twist tie. A desiccant may be placed between the bags. The drum provides protection from light and mechanical strength to protect the liner during shipment and handling. The majority of the protection from air and moisture is provided by the liner. Because LDPE is not a particularly good moisture barrier, a drug substance that is moisture sensitive may need additional protection. An alternative to a LDPE bag is a heat-sealable laminate bag with a comparatively low rate of water vapor transmission. Qualification of the packaging system is usually based on establishing compatibility and safety of the liner but may also include characterization for solvent or gas transmission (see section III.B). The container closure system for the storage or shipment of a bulk liquid drug substance is typically plastic, stainless steel, a glass-lined metal container, or an epoxy-lined metal The 1987 stability guidance will be superseded by the FDA guidance for industry Stability Testing of Drug Substances and Drug Products, issued in draft for comment in June 1998, once it is issued in final form. container with a rugged, tamper-resistant closure. Qualification of the container closure system may include characterization for solvent and gas permeation, light transmittance, closure integrity, ruggedness in shipment, protection against microbial contamination through the closure, and compatibility and safety of the packaging components as appropriate (see section III.B). The application (or Type II DMF) should include a detailed description of the complete container closure system for the bulk drug substance as well as a description of the specific container, closure, all liners, inner seal, and desiccant (if any), and the composition of each component. A reference to the appropriate indirect food additive regulation is typically considered sufficient to establish the safety of the materials of construction (also note the discussion on this subject in section III). The tests, methods, and criteria for the acceptance and release of each packaging component should be provided. Stability studies to establish a retest period for bulk drug substance in the proposed container closure system should be conducted with fillers or desiccant packs in place (if used). Smaller versions which simulate the actual container closure system may be used. Stability recommendations for container closure systems of different types are described in the Guideline for Submitting Documentation for the Stability of Human Drugs and Biologics (February 1987).23 Container closure systems for compressed medical gases are discussed in section III.H. B. Containers for Bulk Drug Products A container closure system for bulk drug products may be used for storage prior to packaging or for shipment to repackagers or contract packagers. In all cases, the container closure system should adequately protect the dosage form and should be constructed of materials that are compatible and safe. Container closure systems for on-site storage have generally been considered a CGMP issue under 21 CFR 211.65. However, if a firm plans to hold bulk drug products in storage, then the container closure system and the maximum storage time should be described and justified in the application. In addition, stability data should be provided to demonstrate that extended storage in the described containers does not adversely affect the dosage form. Even when the storage time before packaging will be short, a firm should use a container closure system that provides adequate protection and that is manufactured from materials that are compatible and safe for the intended use (see section III.B). FDA Compliance Policy Guides, "Regulatory Action Regarding Approved New Drugs and Antibiotic Drug Products Subjected to Additional Processing or other Manipulation," Section 446.100, January 18, 1991 (CPG 7132c.06). A container closure system for the transportation of bulk drug products to contract packagers (section II.C.3) should be described in the application. The container closure system should be adequate to protect the dosage form, be constructed with materials that are compatible with product being stored, and be safe for the intended use. The protective properties of the shipping container are verified by the practice of including annual batches of the packaged product in postapproval stability studies. A container closure system specifically intended for the transportation of a large volume of drug product to a repackager (section II.C.3), whether for a solid or liquid dosage form, is considered a market package. The package should meet the same requirements for protection, compatibility, and safety as a smaller market package; should be included in the stability studies for application approval and in the long term stability protocol; and should be fully described in the application. The length of time that the dosage form will spend in the bulk container may be a factor in determining the level of detail of the supporting information. Two examples of a large-volume shipping package are a 10,000- tablet HDPE pail with tamper-evident closure, and a 10-liter polyethylene terephthalate (PET) container with a screw cap closure with dispenser attachment for a liquid drug product. Both are intended for sale to a mass distribution pharmacy. A special case is the pharmacy bulk package which is described in USP <1>. Applicants should check the appropriate sources directly for the most up-to-date information. A-1 ATTACHMENT A25 REGULATORY REQUIREMENTS 1. The Federal Food, Drug, and Cosmetic Act a. Section 501 A drug or device shall be deemed to be adulterated “if its container is composed, in whole or in part, of any poisonous or deleterious substance which may render the contents injurious to health” (section 501(a)(3)); or “if it is a drug and the methods used in, or the facilities or controls used for, its manufacture, processing, packing, or holding do not conform to or are not operated or administered in conformity with current good manufacturing practice to assure that such drug meets the requirements of this Act as to safety and has the identity and strength, and meets the quality and purity characteristics, which it purports or is represented to possess (section 501(a)(2)(B)). b. Section 502 A drug or device shall be deemed to be misbranded: C “[i]f it purports to be a drug the name of which is recognized in an official compendium, unless it is packaged and labeled as prescribed therein” (section 502(g)) C “[i]f it is a drug and its container is so made, formed, or filled as to be misleading” (section 502(i)(1)) C “[i]f it is a drug and its packaging or labeling is in violation of an applicable regulation issued pursuant to section 3 or 4 of the Poison Prevention Packaging Act of 1970" (section 502(p)) c. Section 505 “No person shall introduce or deliver for introduction into interstate commerce any new drug, unless an approval of an application filed pursuant to subsection (b) or (j) is effective with respect to such drug” (section 505(a)). Section 505(b)(1)(D) requires "a full description of the methods used in, and the A-2 facilities and controls used for, the manufacture, processing, and packing of such drug." 2. The Code of Federal Regulations a. 21 CFR 211 - Current Good Manufacturing Practice for Finished Pharmaceuticals i. Subpart E, Control of Components and Drug Product Containers and Closures (21 CFR 211.80 - 211.94) In particular, 21 CFR 211.94 outlines the requirements for drug product containers and closures: (a) Drug product containers and closures shall not be reactive, additive, or absorptive so as to alter the safety, identity, strength, quality, or purity of the drug beyond the official or established requirements. (b) Container closure systems shall provide adequate protection against foreseeable external factors in storage and use that can cause deterioration or contamination of the drug product. (c) Drug product containers and closures shall be clean and, where indicated by the nature of the drug, sterilized and processed to remove pyrogenic properties to ensure that they are suitable for their intended use. (d) Standards or acceptance criteria, test methods, and, where indicated, methods of cleaning, sterilizing, and processing to remove pyrogenic properties shall be written and followed for drug product containers and closures. ii. Subpart F, Production and Process Controls (21 CFR 211.100 - 211.115) iii. Subpart G, Packaging and Labeling Control (21 CFR 211.122 - 211.137) In particular, 21 CFR 211.132 describes the tamper-resistant packaging requirements for over-the-counter (OTC) human drug products. Most OTC drug products must be packaged in tamper-resistant containers. b. 16 CFR 1700-1702 - Special Packaging The U.S. Consumer Product Safety Commission (CPSC) is responsible for enforcing the Poison Prevention Packaging Act of 1970 (PPPA). The PPPA requires special packaging of hazardous household substances to protect children Federal Register, Volume 49, March 5, 1984, page 8008 (49 FR 8008), “Prescribed Drugs Distributed to Prescribing Practitioners; Withdrawal of Proposed Statement of Policy and Interpretation.” A-3 from serious personal injury or serious illness from handling, using, or ingesting the substances. Drug products containing controlled substances, most human oral prescription drug products (including oral investigational drugs used in outpatient trials), and OTC drug preparations containing aspirin, acetaminophen, diphenhydramine, liquid methyl salicylate, ibuprofen, loperamide, lidocaine, dibucaine, naproxen, iron, or ketoprofen, require special packaging (16 CFR 1700.14). Special packaging is defined under 15 U.S.C. 1471(2)(4), 16 CFR 1700.1(b)(4), and 21 CFR 310.3(l). Regulations issued under the PPPA establish performance standards and test methods that determine if a packaging system is child-resistant and adult-use-effective (16 CFR 1700.15 and 16 CFR 1700.20, respectively). Except as noted below, all PPPA-regulated substances must be in packaging systems that comply with these special packaging standards. The standards apply to both reclosable and nonreclosable packaging systems (unit-dose packaging). There are several situations where child-resistant packaging for drug products is not required. Manufacturers and packagers of bulk-packaged prescription drug products do not have to use special packaging if the drug is intended to be repackaged by the pharmacist. However, the manufacturer or packager is responsible for child-resistant packaging if the drug product is intended to be dispensed to the consumer as packaged without repackaging by the pharmacist (16 CFR 1701.1). Prescribed drugs that are dispensed for use within institutions such as hospitals and nursing homes do not require child-resistant packaging. However, any prescriptions dispensed to patients upon their release for their use at home would be subject to the PPPA packaging requirements. In addition, drug product manufacturers are not required to provide child-resistant packaging for prescription drug samples that are distributed to physicians and other prescribing practitioners (i.e., physician samples).26 For OTC preparations, manufacturers or packagers are allowed to market one size in non-child-resistant packaging as long as child-resistant packages are also supplied. The non-child-resistant package requires special labeling (16 CFR 1700.5). 16 CFR 1702 establishes the procedures for petitioning the CPSC for an exemption from the PPPA requirements. Several prescription drugs (e.g., oral contraceptives in mnemonic packages, powdered colestipol, and medroxyprogesterone acetate) have been exempted from the special packaging requirements (16 CFR 1700.14(10)(I)-(xix)). The CPSC is permitted to grant an A-4 exemption if it finds that packaging is not required to protect children from serious injury, or that special packaging is not technically feasible, practicable, or appropriate for that product. For additional information regarding these packaging requirements and the protocol test methods, please contact the CPSC. Their website is located at www.cpsc.gov and their hotline is 1-800-638-2772. c. 21 CFR 174-186 - Indirect Food Additive Regulations Regulations that are applicable to packaging components are: i. Part 174 - Indirect Food Additives: General ii. Part 175 - Indirect Food Additives: Adhesives and Components of Coatings e.g., ### 175.105 Adhesives ### 175.300 Resinous and polymeric coatings iii. Part 176 - Indirect Food Additives: Paper and Paperboard Components e.g., ### 176.170 Components of paper and paperboard in contact with aqueous and fatty foods ### 176.180 Components of paper and paperboard in contact with dry food iv. Part 177 - Indirect Food Additives: Polymers e.g., ### 177.1380 Fluorocarbon resins ### 177.1520 Olefin polymers ### 177.1630 Polyethylene phthalate polymers v. Part 178 - Indirect Food Additives: Adjuvants, Production Aids, and Sanitizers vi. Part 180 - Food Additives Permitted in Food or in Contact with Food on an Interim Basis Pending Additional Studies e.g., ### 180.22 Acrylonitrile copolymers vii. Part 182 - Substances Generally Recognized as Safe e.g., ### 182.70 Substances migrating from cotton and cotton fabrics A-5 used in dry food packaging ### 182.90 Substances migrating to food from paper and paperboard products viii. Part 186 - Indirect Food Substances Affirmed as Generally Recognized as Safe (GRAS) e.g., ### 186.1673 Pulp d. Biologics Provisions, 21 CFR 600, Subpart B, Establishment Standards i. 21 CFR 600.11(h) - Containers and Closures ii. 21 CFR 601.2 - Applications for Licenses; Procedures for Filing e. Other Sections i. 21 CFR 201 - Labeling ii. 21 CFR 310.509 - Parenteral drug products in plastic containers iii. 21 CFR 200.50(a)(3) - Containers of ophthalmic preparations 3. U.S. Pharmacopeia/National Formulary The following sections are applicable to packaging components: a. General Notices - PRESERVATION, PACKAGING, STORAGE, AND LABELING b. General Tests and Assays <1> Injections <51> Antimicrobial Preservatives - Effectiveness <61> Microbial Limit Tests <71> Sterility Tests <87> Biological Reactivity Tests, in vitro <88> Biological Reactivity Tests, in vivo <161> Transfusion and Infusion Assemblies <381> Elastomeric Closures for Injections C Biological Test Procedures C Physicochemical Test Procedures <601> Aerosols <661> Containers A-6 C Light Transmission C Chemical Resistance - Glass Containers C Biological Tests - Plastics and Other Polymers C Physicochemical Tests - Plastics C Containers for Ophthalmics - Plastics C Polyethylene Containers C Polyethylene Terephthalate Bottles and Polyethylene Terephthalate G Bottles C Single-Unit Containers and Unit-Dose Containers for Nonsterile Solid and Liquid Dosage Forms C Customized Patient Medication Packages <671> Containers - Permeation C Multiple-Unit Containers for Capsules and Tablets C Single-Unit Containers and Unit-Dose Containers for Capsules and Tablets <691> Cotton (or the monograph for Purified Rayon USP) <771> Ophthalmic Ointments <1041> Biologics <1151> Pharmaceutical Dosage Forms B-1 ATTACHMENT B COMPLIANCE POLICY GUIDES THAT CONCERN PACKAGING (August 1996) Compliance Policy Guides are issued by the Division of Compliance Policy (in the Office of Enforcement/Office of Regulatory Affairs). The following is a list of Compliance Policy Guides that concern packaging. Any questions or concerns about the content of any Compliance Policy Guide should be addressed to the Office of Enforcement/Office of Regulatory Affairs/Division of Compliance Policy at 301-827-0420 (telephone), 301-827-0482 (FAX) or www.fda.gov/ora/compliance_ref/cpg/default.html (Internet). Sub Chapter 410 BULK DRUGS Sec. 410.100 Finished Dosage Form Drug Products in Bulk Containers - Applications of Current Good Manufacturing Practice Regulations (CPG 7132a.06) Sub Chapter 430 LABELING and REPACKAGING Sec. 430.100 Unit Dose Labeling for Solid and Liquid Oral Dosage Forms (CPG 7132b.10) Sec. 430.200 Repacking of Drug Products - Testing/Examination Under CGMPs (CPG 7132.13) Sub Chapter 440-448 NEW DRUGS Sec. 446.100 Regulatory Action Regarding Approved New Drugs and Antibiotic Drug Products Subjected to Additional Processing or Other Manipulations (CPG 7132c.06) Sub Chapter 450-457 OTC Sec. 450.500 Tamper-Resistant Packaging Requirements for Certain Over-the- Counter (OTC) Human Drug Products (CPG 7132a.17) Sec. 450.550 Control and Accountability of Labeling Associated with Tamper- Resistant Packaging of Over-the-Counter Drug Products (CPG 7132.14 ) Sub Chapter 480 STABILITY/EXPIRATION B-2 Sec. 480.100 Requirements for Expiration Dating and Stability Testing (CPG 7132a.04) Sec. 480.200 Expiration Dating of Unit Dose Repackaged Drugs (CPG 7132b.11) Sec. 480.300 Lack of Expiration Date of Stability Data (CPG 7132a.10) C-1 ATTACHMENT C EXTRACTION STUDIES An extraction study of a packaging component typically involves exposing a sample of the component, often subdivided into small pieces to increase surface area, to an appropriate solvent system at elevated temperatures, followed by chemical analysis. The purpose of elevated temperature is to increase the rate of extraction, so that a short experimental time may simulate a longer exposure time at room temperature, or to maximize the amount of extractables obtained from a sample. The methods employed to analyze the resulting extracts vary, depending on the purpose of the extraction study and the nature of the packaging component. The extraction solvent may be evaporated to concentrate the extracts or to determine the total weight of nonvolatile extractables. Appropriate methods, such as HPLC or gas chromatography, may be used to obtain qualitative or quantitative extraction profiles of volatile or nonvolatile extractables. Extraction studies may be conducted during the qualification of packaging components for any of the following purposes: C To perform USP characterization tests on plastics (USP <661>) or elastomers (USP <381>) C To perform USP Biological Reactivity Tests (USP <87> and <88>) on plastics or elastomers C To obtain qualitative extraction profiles of plastics or elastomers C To obtain quantitative extraction profiles of plastics or elastomers C To evaluate whether the FDA indirect food additive regulations provide an adequate indicator of safety Extraction studies may also be conducted on a routine basis as a quality control measure to monitor the chemical compositions of elastomeric or other packaging components. The solvent that should be used in an extraction study depends on the purpose of the study. The ideal situation is for the extracting solvent to have the same propensity to extract substances as the dosage form, thus obtaining the same quantitative extraction profile. For this study, the preferred solvent would be the drug product or placebo vehicle. When feasible, the dosage form itself would be used. A stronger extracting solvent than the drug product would be used to obtain a qualitative extraction profile that would be used to establish quality control criteria. D-1 ATTACHMENT D ABBREVIATIONS AAO American Academy of Ophthalmology ANDA Abbreviated New Drug Application BLA Biologics License Application CBER Center for Biologics Evaluation and Research CDER Center for Drug Evaluation and Research CFR Code of Federal Regulations CFSAN Center for Food Safety and Applied Nutrition CGMP Current Good Manufacturing Practice CMC Chemistry, Manufacturing, and Control COA Certificate of Analysis CPSC Consumer Product Safety Commission DMF Drug Master File DPI Dry Powder Inhaler FDA U.S. Food and Drug Administration (the Agency) HDPE High Density Polyethylene IND Investigational New Drug Application LDPE Low Density Polyethylene LOA Letter of Authorization LVP Large-Volume Parenteral MDI Metered Dose Inhaler NDA New Drug Application PET Polyethylene Terephthalate PETG Polyethylene Terephthalate G PP Polypropylene PVC Polyvinyl Chloride QA Quality Assurance QC Quality Control SVP Small-Volume Parenteral USP/NF U.S. Pharmacopeia/National Formulary A list of CDER and CBER guidances and guidelines is provided on the Internet at www.fda.gov/cder/guidances.index.htm and www.fda.gov/cber/guidelines.htm, respectively. E-1 ATTACHMENT E REFERENCES27 Center for Drug Evaluation and Research (CDER) Compressed Medical Gases Guideline (February 1989) FDA Guideline for Drug Master Files (September 1989) FDA Guidance for Industry on the Submission of Documentation for the Sterilization Process Validation in Applications for Human and Veterinary Drug Products (November 1994) FDA Guidance for Industry on the Content and Format on Investigational New Drug Applications (INDs) for Phase 1 Studies of Drugs, Including Well Characterized, Therapeutic, Biotechnology-Derived Products (November 1995) FDA Guidance for Industry on the Submission of Chemistry, Manufacturing, and Controls Information for a Therapeutic Recombinant DNA-Derived Product or a Monoclonal Antibody Product for In Vivo Use (August 1996) FDA Guidance for Industry on the Submission of Chemistry, Manufacturing, and Controls Information and Establishment Description for Autologous Somatic Cell Therapy Products (January 1997) FDA Guidance for the Photostability Testing of New Drug Substance and Products (May 1997) FDA Guidance for Industry on the Submission of Chemistry, Manufacturing, and Controls Information for Synthetic Peptide Substances (January 1998) FDA Guidance for Industry on the Content and Format of Chemistry, Manufacturing, and Controls and Establishment Description Information for a Vaccine or Related Product (January 1999) FDA Guidance for Industry for the Submission of Chemistry, Manufacturing, and Controls and Establishment Description Information for Human Plasma-Derived Biological Product or Animal Plasma or Serum-Derived Products (February 1999) FDA Guidance for Industry on the Content and Format of Chemistry, Manufacturing, and E-2 Controls and Establishment Description Information for a Biological In Vitro Diagnostic Product (March 1999) FDA Guidance for Industry on the Content and Format of Chemistry, Manufacturing, and Controls and Establishment Description Information for Allergenic Extract or Allergen Patch Test (April 1999) FDA Guidance for Industry for the Submission of Chemistry, Manufacturing, and Controls and Establishment Description Information for Human Blood and Blood Components Intended for Transfusion or for Further Manufacture and for the Completion of the FDA Form 356h, Application to Market a New Drug, Biologic, or an Antibiotic Drug for Human Use (May 1999) --- ### Document: FDA GlassVial Complete (FDA) # FDA Guidance for Industry: Container Closure System and Component Changes: Glass Vials and Stoppers (2024) Container Closure System and Component Changes: Glass Vials and Stoppers Guidance for Industry U.S. Department of Health and Human Services Food and Drug Administration Center for Drug Evaluation and Research (CDER) Center for Biologics Evaluation and Research (CBER) July 2024 Pharmaceutical Quality/Manufacturing Standards Container Closure System and Component Changes: Glass Vials and Stoppers Guidance for Industry Additional copies are available from: Office of Communications, Division of Drug Information Center for Drug Evaluation and Research Food and Drug Administration 10001 New Hampshire Ave., Hillandale Bldg., 4th Floor Silver Spring, MD 20993-0002 Phone: 855-543-3784 or 301-796-3400; Fax: 301-431-6353 Email: druginfo@fda.hhs.gov https://www.fda.gov/drugs/guidance-compliance-regulatory-information/guidances-drugs and/or Office of Communication, Outreach and Development Center for Biologics Evaluation and Research Food and Drug Administration 10903 New Hampshire Ave., Bldg. 71, Room 3128 Silver Spring, MD 20993-0002 Phone: 800-835-4709 or 240-402-8010 Email: ocod@fda.hhs.gov https://www.fda.gov/vaccines-blood-biologics/guidance-compliance-regulatory-information-biologics/biologics-guidances U.S. Department of Health and Human Services Food and Drug Administration Center for Drug Evaluation and Research (CDER) Center for Biologics Evaluation and Research (CBER) July 2024 Pharmaceutical Quality/Manufacturing Standards Contains Nonbinding Recommendations i TABLE OF CONTENTS I. INTRODUCTION............................................................................................................. 1 II. REGULATORY APPROACHES TO CMC CHANGES ............................................. 2 III. COMMON CHANGES RELATED TO GLASS VIALS AND STOPPERS .............. 4 IV. TOOLS TO FACILITATE CHANGES TO CCS COMPONENTS ............................ 5 A. Risk-Based Considerations for Supplement Reporting Categories ........................................... 5 B. Comparability Protocols ............................................................................................................... 6 REFERENCES .............................................................................................................................. 7 APPENDIX: TABLES DESCRIBING CCS CHANGES FOR PRODUCTS WITH APPROVED ANDAS, NDAS, OR BLAS ................................................................................. 10 Contains Nonbinding Recommendations Container Closure System and Component Changes: Glass Vials and Stoppers Guidance for Industry1 This guidance represents the current thinking of the Food and Drug Administration (FDA or Agency) on this topic. It does not establish any rights for any person and is not binding on FDA or the public. You can use an alternative approach if it satisfies the requirements of the applicable statutes and regulations. To discuss an alternative approach, contact the FDA office responsible for this guidance as listed on the title page. I. INTRODUCTION FDA is issuing this guidance to collate recommendations for appropriate reporting categories and the content of postapproval change submissions across numerous FDA guidance documents.2 This guidance conveys recommendations to holders of approved new drug applications (NDAs), biologics license applications (BLAs), and abbreviated new drug applications (ANDAs) regarding the reporting and implementation of some common changes to container closure system (CCS) components consisting of glass vials and stoppers for approved3 sterile drug products, including biological products, administered parenterally. This guidance also discusses pathways available to application holders to obtain Agency feedback. Additionally, this guidance discusses risk-based tools available to facilitate the implementation of changes to CCSs consisting of glass vials and stoppers. This guidance does not apply to CCS types other than glass vials and stoppers. 1 This guidance has been prepared by the Office of Pharmaceutical Quality in the Center for Drug Evaluation and Research in cooperation with the Center for Biologics Evaluation and Research at the Food and Drug Administration. You may submit comments on this guidance at any time. Submit comments to Docket No. FDA- 2017-D-6821 (available at https://www.regulations.gov/docket?D=FDA-2017-D-6821). See the instructions in that docket for submitting comments on this and other Level 2 guidances. 2 In March 2021, FDA published the guidance for industry COVID-19 Container Closure System and Component Changes: Glass Vials and Stoppers, which provided recommendations regarding the reporting and implementation of some common changes to container closure system (CCS) components consisting of glass vials and stoppers for approved sterile drugs. That guidance was intended to remain in effect only for the duration of the public health emergency related to COVID-19 declared by the Secretary of Health and Human Services under section 319 of the Public Health Service Act (section 319 public health emergency), which has now expired. FDA is issuing this final guidance because many of the recommendations set forth in the 2021 guidance are applicable outside the context of the section 319 public health emergency. 3 Although this guidance does not principally address data recommendations for original applications pending approval, the risk-based regulatory approaches discussed in this guidance, other guidance documents referenced in References, and the data recommendations provided in the tables in Appendix may be useful during product development and for original application submission. Should an applicant need to change CCS components before product approval, the applicant should proactively seek feedback from the appropriate FDA review division to mitigate the effect of the change on the review timeline of the pending application. Contains Nonbinding Recommendations In general, FDA’s guidance documents do not establish legally enforceable responsibilities. Instead, guidances describe the Agency’s current thinking on a topic and should be viewed only as recommendations, unless specific regulatory or statutory requirements are cited. The use of the word should in Agency guidances means that something is suggested or recommended, but not required. II. REGULATORY APPROACHES TO CMC CHANGES As described in section 506A of the Federal Food, Drug, and Cosmetic Act (21 U.S.C. 356a), 21 CFR 314.70, 21 CFR 314.97, and 21 CFR 601.12, an applicant must notify FDA about changes in each condition (e.g., the product, production process, quality controls, equipment, facilities, or labeling) established in an approved application beyond the variations already provided for in the application. The reporting category for such changes depends on the potential to have an adverse effect on the identity, strength, quality, purity, or potency of the product as these factors may relate to the safety or effectiveness of the product. Therefore, changes can range from those that require approval before implementation (prior approval supplement (PAS)), those that require notification 30 days before (changes being effected in 30 days (CBE-30)), or upon implementation (changes being effected), and those where notification can be provided after implementation (annual report). Some of these identified changes, depending on the circumstances, may be more appropriately submitted as an original application instead of as supplements.4 FDA has conveyed additional clarification regarding reporting of CMC changes to an NDA, BLA, and ANDA in guidance documents specific to various application types and product dosage forms (see References). The content in section IV. Common Changes Related to Glass Vials and Stoppers related to changes to glass vials and stoppers for finished drug and biological products includes content derived from the referenced guidance documents. FDA applies a risk-based approach to the evaluation of proposed CMC changes to a CCS (e.g., changes in components, composition, container type, suppliers, and manufacturers), taking into consideration the characteristics of the specific product. The suitability and compatibility of a CCS depends not only on the properties of a container, but also on the properties of other CCS components and their interactions with the drug product formulation over its intended shelf life. Applicants must validate the effects of the change prior to distribution of the drug,5 and, as appropriate, conduct additional qualification tests or submit information to address product- specific risks as part of that assessment. For example, this additional information to be submitted to FDA could include studies to assess: the effect of formulation attributes such as high pH; the effect of factors that increase the potential for glass delamination, particulate matter, leachables, or interactions of labile molecules with leachables (such as susceptibility of some proteins to interact with metal ions); or the effect of the lyophilization process on product quality. Finally, 4 Applicants can consult the appropriate Center for Drug Evaluation and Research or Center for Biologics Evaluation and Research review division for questions regarding circumstances where an original application or supplement should be submitted. 5 See section 506A(b) of the FD&C Act and pertinent regulations at 21 CFR 314.70(a)(2), 21 CFR 314.97(a) (incorporating 21 CFR 314.70 by reference), and 21 CFR 601.12(a)(2). Contains Nonbinding Recommendations applicable tests and studies as outlined in United States Pharmacopeia (USP) chapters6 should be conducted to demonstrate the suitability of the glass vial following a change; such tests must be conducted where needed to ensure continued compliance with compendial standards for strength, quality, or purity of the drug.7 FDA encourages applicants to submit the appropriate postapproval supplement type as recommended by the existing guidance documents for proposed changes to the CCS. FDA may consider available risk evaluations and product quality risk mitigation strategies to support a lower reporting category for specific changes. FDA recommends applicants use the risk management principles described in the ICH guidance for industry Q9(R1) Quality Risk Management (May 2023), and tools described in ICH guidance for industry Q12 Technical and Regulatory Considerations for Pharmaceutical Product Lifecycle Management (May 2021), where appropriate. Whether or not a change is required to be reported to FDA, in accordance with applicable regulations,8 FDA expects all changes to be appropriately managed by an establishment’s/facility’s pharmaceutical quality system under the applicable current good manufacturing practice regulations in 21 CFR parts 210, 211, and 600. Applicants should also refer to the recommendations in the ICH guidance for industry Q10 Pharmaceutical Quality System (April 2009). A supplement for a CCS-related change should include information to support the proposed change and can incorporate certain information by reference to a drug master file (DMF), where appropriate. However, when incorporating information by reference to a DMF, the supplement should also include sufficient product-specific information to support the change. Applicants are ultimately responsible for assessing the effects of the proposed change(s) on product quality, and ensuring that information to support the change is provided for a complete submission of a supplement or annual report.9 DMF holders must notify affected authorized parties of any DMF changes, additions, or deletions.10 DMF holders also should provide application holders with sufficient information to determine the appropriate reporting category for their applications based on the potential to have an adverse effect on the identity, strength, quality, purity, or potency of the product as these factors may relate to the safety or effectiveness of the product. This notification should occur well before making any changes to permit authorized parties to submit application changes within an appropriate time frame. For additional information on DMF submission guidelines, refer to 21 CFR 314.420, 21 CFR 601.51(a), and the draft guidance for industry Drug Master Files (October 2019).11 6 See USP General Chapters <381> Elastomeric Closure for Injections, <660> Glass Containers Used in Pharmaceutical Packaging/Delivery Systems, <1207> Package Integrity Evaluation — Sterile Products, <1660> Evaluation of the Inner Surface Durability of Glass Containers. 7 See section 501(b) of the FD&C Act. 8 21 CFR 314.70, 21 CFR 314.97, and 21 CFR 601.12. 9 21 CFR 314.70, 21 CFR 314.97, and 21 CFR 601.12. 10 21 CFR 314.420(c). 11 In June 2014, FDA issued the guidance for industry Drug Master Files: Guidelines. In October 2019, FDA issued the revised draft guidance for industry Drug Master Files. When final, this guidance will represent FDA’s current thinking on this topic. We update guidances periodically. For the most recent version of a guidance, check the FDA guidance web page at https://www.fda.gov/regulatory-information/search-fda-guidance-documents. Contains Nonbinding Recommendations This guidance is not intended to alter existing submission processes; applicants should follow the recommendations in current guidance documents for reporting CMC changes to an approved application (see References). III. COMMON CHANGES RELATED TO GLASS VIALS AND STOPPERS The tables in the Appendix of this guidance include information derived from existing FDA guidance documents that contain recommendations for reporting category and submission content related to common CMC changes to CCS components (glass vials and stoppers) for finished drug and biological products. The tables include the type of data recommended to support a specific change (as discussed in the guidance for industry Container Closure Systems for Packaging Human Drugs and Biologics; Chemistry, Manufacturing, and Controls Documentation (May 1999)), as well as the recommended reporting category. Some recommendations regarding data submission and reporting categories may differ based on the nature of the product and the potential risk to product quality as it may relate to safety and effectiveness of the product. The quantity of data that should be included in the submission depends on the application type and available body of knowledge.12 Changes should be supported with confirmatory13 batch data. To assess the change, FDA may request that the applicant provide additional information in the supplement or referenced DMF. An applicant seeking to make more than one related change concurrently should submit a supplement with data appropriate to address the potential risk from the cumulative effect of multiple changes. Where the recommended reporting categories for the individual changes differ, the submission category selected should be the one associated with the highest risk change (e.g., PAS) of the categories recommended for the individual changes. When the CCS changes described in the Appendix tables necessitate a corresponding change in finished product specifications,14 the applicant should provide all studies and data appropriate to support the affected specification change(s). The reporting category depends on the potential to have an adverse effect on the identity, strength, quality, purity, or potency of the product as these factors may relate to the safety or effectiveness of the product. For example, tightening the acceptance criteria for a quality attribute may warrant a lower reporting category than widening the acceptance criteria. 12 The quantity of data recommended in the Appendix tables for NDAs, ANDAs, and BLAs is derived from related guidance documents. For example, the number of batches is derived from principles outlined in scale-up and postapproval changes guidance documents (e.g., 1 to 3 batches for ANDAs and NDAs depending on the body of knowledge). Where guidance documents do not provide specific information on the quantity of data expected to support the change, the applicant may contact FDA to obtain feedback. 13 For the purposes of this guidance, confirmatory data means comparative product batch data (on product manufactured prior to and after the proposed change) that is sufficient to demonstrate no adverse effect on product quality due to the proposed CCS change. 14 The ICH guidances for industry Q6A Specifications: Test Procedures and Acceptance Criteria for New Drug Substances and New Drug Products: Chemical Substances (December 2000) and Q6B Specifications: Test Procedures and Acceptance Criteria for Biotechnological/Biological Products (August 1999) define specifications as “a list of tests, references to analytical procedures, and appropriate acceptance criteria that are numerical limits, ranges, or other criteria for the tests described.” Contains Nonbinding Recommendations Before introducing a new CCS component that differs from the specified CCS component type/grade in product labeling (e.g., “packaged in type 1 glass”), a supplement to change product labeling may be appropriate. When the CCS new component differs from that specified in the applicable USP monograph, appropriate engagement with USP regarding an update to the product monograph15 may be necessary to ensure continued compliance with the monograph.16 IV. TOOLS TO FACILITATE CHANGES TO CCS COMPONENTS For CCS and component changes that are the subject of this guidance, FDA intends to consider risk-based approaches using existing tools and capabilities to facilitate providing timely feedback, guidance, and assessment of proposed changes as discussed below. FDA may expedite the assessment of a supplement or determine that a different reporting category is appropriate, taking into account public health priorities17 and the applicant’s rationale and associated risk assessment and mitigation strategy for the proposed change. Should a different reporting category be determined to be appropriate, FDA will notify the applicant and convey its rationale for the determination.18 A. Risk-Based Considerations for Supplement Reporting Categories Consistent with applicable regulations and existing guidance documents related to postapproval CMC changes for NDAs, ANDAs, and BLAs, FDA may consider available information and approaches to mitigate the risk to product quality when determining whether a lower reporting category for supplements is appropriate. Applicants should consider using tools in ICH Q12 (e.g., established conditions, postapproval change management protocols (PACMPs)) to support proposals for reduced reporting categories based on an increased understanding of the risk to product quality when making a change related to the glass vial or stopper. Before submitting a supplement with a lower reporting category than what is required in existing regulations and recommended in existing guidance, applicants should contact FDA for feedback and concurrence. For Center for Drug Evaluation and Research (CDER)-regulated products, applicants should contact the regulatory project management staff (regulatory project manager or 15 For additional information, see the draft guidance for industry Harmonizing Compendial Standards With Drug Application Approval Using the USP Pending Monograph Process (July 2019). When final, this guidance will represent FDA’s current thinking on this topic. 16 See section 501(b) of the FD&C Act. 17 For additional information, see 21 CFR 314.70(b)(4). For FDA policies describing expedited review requests related to prior approval supplements to NDAs and BLAs, see MAPP 5310.3 Rev 1 Requests for Expedited Review of New Drug Application and Biologics License Application Prior Approval Supplements Submitted for Chemistry, Manufacturing, and Controls Changes; for FDA policies describing prioritization of the review related to original ANDAs, amendments, and supplements thereof, see MAPP 5240.3 Rev. 5 Prioritization of the Review of Original ANDAs, Amendments, and Supplements; for FDA policies on drug shortage management, see MAPP 4190.1 Rev. 3 Drug Shortage Management. MAPPs are available at https://www.fda.gov/about-fda/center-drug-evaluation-and- research-cder/cder-manual-policies-procedures-mapp. 18 Depending on the regulatory jurisdiction of the product, the applicant can contact the responsible review division within CDER or CBER (as applicable) to gain additional feedback on specific changes, the information needed to support the change, and the filing approach, as needed. Contains Nonbinding Recommendations regulatory business process manager) within the appropriate CDER review office responsible for the subject product application. For Center for Biologics Evaluation and Research (CBER)- regulated products, applicants should contact the appropriate CBER review office. Additionally, if the CDER- or CBER-regulated product could enter, or is currently in, drug shortage, then the respective applicant should include drugshortages@fda.hhs.gov for products regulated by CDER and cbershortage@fda.hhs.gov for products regulated by CBER on those communications. B. Comparability Protocols As explained in the guidance for industry Comparability Protocols for Postapproval Changes to the Chemistry, Manufacturing, and Controls Information in an NDA, ANDA, or BLA (October 2022), a comparability protocol (CP) is a comprehensive, prospectively written plan for assessing the effect of a proposed CMC postapproval change(s) on the identity, strength, quality, purity, and potency of a drug product or a biological product. It is a tool for applicants to obtain feedback from FDA on prospective scientific approaches, submitted as a part of an original application or PAS, to facilitate expeditious implementation of postapproval changes. CPs allow FDA to review a description of one or more proposed CMC postapproval changes, supporting information (including any analysis and risk assessment activities), the plan for implementing the change(s), and, if appropriate, the proposed reduced reporting category for the change(s). By delineating the specific approach to be used to evaluate one or more future changes and the rationale for that approach, the applicant can gain the Agency’s approval of the plan well in advance of the need to implement the change(s). This process can facilitate a more efficient submission process for the applicant and review process for FDA. If the original application or PAS containing the CP is approved, the change usually can be implemented under a lower reporting category than would normally be expected based on recommendations in guidance (e.g., changes otherwise requiring a prior approval supplement could be implemented under a CBE-30). A CP can then be used for a one-time change(s) or be used repeatedly for a specified type of change over the life cycle of a product. A CP can also be submitted to cover an identical change(s) that affects multiple applications (grouped supplements, trans-BLA submissions).19 A CP is a well-suited tool for making changes to glass vials and stoppers, because a change to one component can be implemented to many products sharing that container or closure, and the protocol could be used multiple times as the need arises for additional changes to accommodate the dynamic supply chain evolution. 19 See the guidance for industry Chemistry, Manufacturing, and Controls Changes to an Approved Application: Certain Biological Products (June 2021). Contains Nonbinding Recommendations REFERENCES20 Draft and Final Guidances21 • Changes to an Approved Application for Specified Biotechnology and Specified Synthetic Biological Products (July 1997) • Changes to an Approved NDA or ANDA (April 2004) • Changes to an Approved NDA or ANDA; Questions and Answers (January 2001) • Chemistry, Manufacturing, and Controls Changes to an Approved Application: Certain Biological Products (June 2021) • Comparability Protocols for Postapproval Changes to the Chemistry, Manufacturing, and Controls Information in an NDA, ANDA, or BLA (October 2022) • Container Closure Systems for Packaging Human Drugs and Biologics (May 1999) • CMC Postapproval Manufacturing Changes To Be Documented in Annual Reports (March 2014) • CMC Postapproval Manufacturing Changes for Specified Biological Products To Be Documented in Annual Reports (December 2021) • Drug Master Files (October 2019)22 • Harmonizing Compendial Standards With Drug Application Approval Using the USP Pending Monograph Process (July 2019)23 • ICH Q12 Implementation Considerations for FDA-Regulated Products (May 2021)24 • Manufacturing Changes and Comparability for Human Cellular and Gene Therapy Products (July 2023)25 • PAC-ATLS: Postapproval Changes — Analytical Testing Laboratory Sites (April 1998) 20 MAPPs can be found on the CDER Manual of Policies & Procedures web page at https://www.fda.gov/about- fda/center-drug-evaluation-and-research/cder-manual-policies-procedures-mapp, and SOPPs can be found on the Biologics Procedures (SOPPs) web page at https://www.fda.gov/vaccines-blood-biologics/guidance-compliance- regulatory-information-biologics/biologics-procedures-sopps. 21 We update guidances periodically. For the most recent version of a guidance, check the FDA guidance web page at https://www.fda.gov/regulatory-information/search-fda-guidance-documents. 22 When final, this guidance will represent the FDA’s current thinking on this topic. 23 Ibid. 24 Ibid. 25 Ibid. Contains Nonbinding Recommendations • Submission Documentation for Sterilization Process Validation in Applications for Human and Veterinary Drug Products (November 1994) Scale-Up and Postapproval Changes Guidances • SUPAC: Manufacturing Equipment Addendum (December 2014)26 • SUPAC-IR: Questions and Answers about SUPAC-IR Guidance (February 1997) • SUPAC-MR: Modified Release Solid Oral Dosage Forms; Scale-Up and Postapproval Changes: Chemistry, Manufacturing, and Controls; In Vitro Dissolution Testing and In Vivo Bioequivalence Documentation (September 1997) • SUPAC-IR: Immediate Release Solid Oral Dosage Forms; Scale-Up and Postapproval Changes: Chemistry, Manufacturing, and Controls, In Vitro Dissolution Testing, and In Vivo Bioequivalence Documentation (November 1995) • SUPAC-SS: Nonsterile Semisolid Dosage Forms; Scale-Up and Postapproval Changes: Chemistry, Manufacturing, and Controls; In Vitro Release Testing and In Vivo Bioequivalence Documentation (May 1997) ICH Guidances • Q6A Specifications: Test Procedures and Acceptance Criteria for New Drug Substances and New Drug Products: Chemical Substances (December 2000) • Q6B Specifications: Test Procedures and Acceptance Criteria for Biotechnological/Biological Products (August 1999) • Q9(R1) Quality Risk Management (May 2023) • Q10 Pharmaceutical Quality System (April 2009) • Q12 Technical and Regulatory Considerations for Pharmaceutical Product Lifecycle Management (May 2021) Manual of Policies and Procedures27 • MAPP 4190.1 Rev. 3 Drug Shortage Management 26 When final, this guidance will represent the FDA’s current thinking on this topic. 27 MAPPs can be found on the CDER Manual of Policies & Procedures web page at https://www.fda.gov/about- fda/center-drug-evaluation-and-research/cder-manual-policies-procedures-mapp. Contains Nonbinding Recommendations • MAPP 5240.3 Rev. 6 Prioritization of the Review of Original ANDAs, Amendments, and Supplements • MAPP 5310.3 Rev. 2 Requests for Expedited Review of New Drug Application and Biologics License Application Prior Approval Supplements Submitted for Chemistry, Manufacturing, and Controls Changes Standard Operating Procedures and Policies28 • SOPP 8506 Management of Shortages of CBER-Regulated Products 28 SOPPs can be found on the CBER Biologics Procedures (SOPPs) web page at https://www.fda.gov/vaccines- blood-biologics/guidance-compliance-regulatory-information-biologics/biologics-procedures-sopps. Contains Nonbinding Recommendations APPENDIX: TABLES DESCRIBING CCS CHANGES FOR PRODUCTS WITH APPROVED ANDAS, NDAS, OR BLAS The following tables include information derived from existing FDA guidance documents containing FDA recommendations for reporting categories and submission content for common chemistry, manufacturing, and controls changes to glass vials and stoppers, the container closure system (CCS) components of finished pharmaceuticals and biological products. These tables provide baseline recommendations for the information to be submitted and the reporting category for specific changes, and do not consider the cumulative effect of concurrent changes. As stated in sections III and IV of the guidance, FDA may request more information to support the change, and determine that a different reporting category is appropriate based on risk assessment information related to the specific change proposed. These tables do not include all possible CCS changes that would necessitate a submission as described in applicable regulations.1 Application holders should consult existing guidance documents for further information on CCS change recommendations. Depending on regulatory jurisdiction of the product application, the applicant can contact the responsible review division within the Center for Drug Evaluation and Research (CDER)2 or the Center for Biologics Evaluation and Research (CBER) (as applicable) to gain additional feedback on specific changes, the information needed to support the change, and the filing approach, as needed. For the following tables, the term confirmatory data means comparative data that demonstrate no adverse impact on product quality due to the proposed CCS change. 1 21 CFR 314.70, 21 CFR 314.97, and 21 CFR 601.12. 2 When the submission is an abbreviated new drug application (ANDA), submit questions through the pre-ANDA meeting or controlled correspondence processes. See the guidances for industry Formal Meetings Between FDA and ANDA Applicants of Complex Products Under GDUFA (November 2020) and Controlled Correspondence Related to Generic Drug Development (December 2020). Contains Nonbinding Recommendations Table A: Changes to the Properties of Glass Vials and Stoppers: New Drug Applications/Abbreviated New Drug Applications* continued Proposed Change Recommended Information to Support the Change Recommended Reporting Category Reference to Current Guidance1 Specific Considerations for Reporting Category Change from glass to a new material (e.g., plastic) Confirmatory batch data, including release and stability data (accelerated and real time•), and data to support sterility assurance Extractables and leachables risk assessment and supporting data PAS Section IX.B.4. of Changes to an Approved NDA or ANDA (April 2004) Change to different composition or type of glass2 Confirmatory batch data, including release and stability data (accelerated and real time), and data to support sterility assurance PAS Sections IX.B.4. and IX.C.1.a. of Changes to an Approved NDA or ANDA FDA may consider a lower reporting category based on the circumstances of the specific change2 Contains Nonbinding Recommendations Table A, continued continued Proposed Change Recommended Information to Support the Change Recommended Reporting Category Reference to Current Guidance1 Specific Considerations for Reporting Category Change between molded and tubing glass Description, composition, drawing, and specification of vial CCS suitability tests and determinations as recommended in USP General Chapter <660> and principles of USP General Chapter <1660> (required for compendial products)3 Confirmatory batch data, including release and stability data (accelerated and real time), and data to support sterility assurance CCIT data Lyophilization cycle verification or validation if process is modified (refer to Specific Considerations for Reporting Category) CBE-30 PAS for lyophilized products (refer to Specific Considerations for Reporting Category) Section IX.C.1.a. of Changes to an Approved NDA or ANDA Changes in vial properties that affect manufacturing processes (e.g., thicker glass affecting lyophilization processes) pose a higher risk to quality and therefore may trigger a higher reporting category with additional data needed to assess the effects of the change Contains Nonbinding Recommendations Table A, continued continued Proposed Change Recommended Information to Support the Change Recommended Reporting Category Reference to Current Guidance1 Specific Considerations for Reporting Category Change in vial dimensions CCIT data Representative media fill/bracketing data Confirmatory batch data, including release and stability data (accelerated and real time), and data to support sterility assurance PAS Section IX.B.4. of Changes to an Approved NDA or ANDA For vials with the same nominal fill volume but slight changes to dimensions, a CBE-30 may be appropriate Switch from amber glass to clear glass (with or without additional photoprotective measures) Confirmatory batch data, including release and stability data (accelerated and real time), and data to support sterility assurance Additional tests based on results of comparative photostability study Labeling change accounting for different storage conditions (e.g., protect from light) PAS Section IX.B.6. of Changes to an Approved NDA or ANDA Contains Nonbinding Recommendations Table A, continued continued Proposed Change Recommended Information to Support the Change Recommended Reporting Category Reference to Current Guidance1 Specific Considerations for Reporting Category Change in primary CCS type (e.g., switching from vial to ampule)4 Description of the container properties and composition Container suitability5 Manufacturing and controls CCIT data Sterilization validation Confirmatory batch data, including release and stability data (accelerated and real time), and data to support sterility assurance PAS Section IX.B.4. of Changes to an Approved NDA or ANDA Contains Nonbinding Recommendations Table A, continued continued Proposed Change Recommended Information to Support the Change Recommended Reporting Category Reference to Current Guidance1 Specific Considerations for Reporting Category Change in stopper rubber/elastomer material6 Description of new stopper Composition Manufacturing and controls Closure suitability7 CCIT data Confirmatory batch data, including release and stability data (accelerated and real time), including vial orientations where formulation is in contact with stopper, and data to support sterility assurance PAS Section IX.B.4. of Changes to an Approved NDA or ANDA Change in stopper dimensions CCIT data Confirmatory batch data, including release and stability data (accelerated and real time), and data to support sterility assurance CBE-30 Section IX.C.1.a. of Changes to an Approved NDA or ANDA Contains Nonbinding Recommendations Table A, continued * PAS = prior approval supplement; CCIT = Container Closure Integrity Test; CBE-30 = changes being effected in 30 days; RTS = ready to sterilize; RTU = ready to use; COA = certificate of analysis; BET = bacterial endotoxins testing • Accelerated and real time refers to batch stability data from accelerated and long-term studies, respectively. 1 We update guidances periodically. For the most recent version of a guidance, check the FDA guidance web page at https://www.fda.gov/regulatory- information/search-fda-guidance-documents. 2 A change in glass supplier without a change in glass type or coating and without a change in container/closure dimensions can be filed as an annual report as described in section 5.4 of Appendix in the guidance for industry CMC Postapproval Manufacturing Changes To Be Documented in Annual Reports (March 2014). 3 United States Pharmacopeia (USP) General Chapter <660> Glass Containers Used in Pharmaceutical Packaging/Delivery Systems, and USP General Chapter <1660> Evaluation of the Inner Surface Durability of Glass Containers. 4 Some of these identified changes, depending on the circumstances, may be more appropriately submitted as an original application instead of as supplements. This type of change may also warrant a labeling change supplement to account for a new presentation. Application holders should follow existing FDA guidance. Applicants can consult the appropriate review division within CDER or CBER if there are questions. 5 Information about the suitability of proposed glass with respect to protection (e.g., container integrity for sterility), safety (e.g., extractables and leachables) and performance. Application holders should refer to USP General Chapter <660> and USP General Chapter <1660> for further information. 6 When alternate suppliers of stoppers are proposed, and if there are differences in stopper properties or manufacturing processes changes between the currently approved and proposed supplier, because of the increased risk to quality, a higher reporting category — PAS — is warranted. However, if the differences in stopper properties and manufacturing processes are minimal then a lower reporting category may be considered. 7 Information about the suitability of proposed stopper with respect to protection (e.g., container integrity for sterility), safety (e.g., extractables and leachables) and performance. Application holders should refer to USP General Chapter <381> Elastomeric Closure for Injections, for additional information. Proposed Change Recommended Information to Support the Change Recommended Reporting Category Reference to Current Guidance1 Specific Considerations for Reporting Category Changes in how the stopper is supplied (e.g., unprocessed, RTS, and RTU) Sterilization and depyrogenation validation Representative COA, which would include sterility and BET data if stoppers are supplied RTU and BET data if stoppers are supplied RTS CBE-30 Section IX.C.1.a. of Changes to an Approved NDA or ANDA Contains Nonbinding Recommendations Table B: Changes to the Properties for Glass Vials and Stoppers: Biologics License Applications* Proposed Change Recommended Information to Support the Change Recommended Reporting Category Reference to Current Guidance1 Specific Considerations for Reporting Category Change from glass to a new material (e.g., plastic) Extractables and leachables risk assessment and supporting data Confirmatory batch data, including release and stability data (accelerated and real time•), and data to support sterility assurance PAS Changes to an Approved Application for Specified Biotechnology and Specified Synthetic Biological Products (July 1997) Section 3.2.P.7. of the Appendix in Chemistry, Manufacturing, and Controls Changes to an Approved Application: Certain Biological Products (June 2021) continued Contains Nonbinding Recommendations Table B, continued Proposed Change Recommended Information to Support the Change Recommended Reporting Category Reference to Current Guidance1 Specific Considerations for Reporting Category Change to different composition or type of glass2 Confirmatory batch data, including release and stability data (accelerated and real time), and data to support sterility assurance PAS BLA: Changes to an Approved Application for Specified Biotechnology and Specified Synthetic Biological Products Section 3.2.P.7. of the Appendix in Chemistry, Manufacturing, and Controls Changes to an Approved Application: Certain Biological Products FDA may consider a lower reporting category based on the circumstances of the specific change (e.g., if the new vial type or composition was previously used in a licensed product) continued Contains Nonbinding Recommendations Table B, continued Proposed Change Recommended Information to Support the Change Recommended Reporting Category Reference to Current Guidance1 Specific Considerations for Reporting Category Change between molded and tubing glass Description, composition, drawing, and specification of vial CCS suitability tests and determinations as recommended in USP General Chapter <660> and principles of USP General Chapter <1660> (required for compendial products)3 CCIT data Confirmatory batch data, including release and stability data (accelerated and real time), and data to support sterility assurance Lyophilization cycle verification or validation if process is modified (refer to Specific Considerations for Reporting Category) AR PAS for lyophilized products with molded vials (refer to Specific Considerations for Reporting Category) Section 3.2.P.7., due to expected change in properties, of the Appendix in Chemistry, Manufacturing, and Controls Changes to an Approved Application: Certain Biological Products Section 5.2 of the ## Appendix in: CMC Postapproval Manufacturing Changes for Specified Biological Products To Be Documented in Annual Reports (December 2021) Changes to an Approved Application for Specified Biotechnology and Specified Synthetic Biological Products Changes in vial properties that affect manufacturing processes (e.g., thicker glass affecting lyophilization processes) pose a higher risk to quality and therefore may trigger a higher reporting category with need for additional data to assess the effects of the change continued Contains Nonbinding Recommendations Table B, continued Proposed Change Recommended Information to Support the Change Recommended Reporting Category Reference to Current Guidance1 Specific Considerations for Reporting Category Change in vial dimensions CCIT data Representative media fill Confirmatory batch data, including release and stability data (accelerated and real time), and data to support sterility assurance Additional accelerated and real time stability data as needed (e.g., concurrent stopper change) PAS BLA: Changes to an Approved Application for Specified Biotechnology and Specified Synthetic Biological Products Section 3.2.P.7. of the Appendix in Chemistry, Manufacturing, and Controls Changes to an Approved Application: Certain Biological Products For vials with the same nominal fill volume but slight changes to dimensions, a CBE-30 may be considered Switch from amber glass to clear glass (with or without additional photoprotective measures) Confirmatory batch data, including release and stability data (accelerated and real time), and data to support sterility assurance Additional tests based on results of comparative photostability study Labeling change accounting for different storage conditions (e.g., protect from light) PAS Same as above continued Contains Nonbinding Recommendations Table B, continued Proposed Change Recommended Information to Support the Change Recommended Reporting Category Reference to Current Guidance1 Specific Considerations for Reporting Category Change in primary CCS type (e.g., switching from vial to ampule)4 Description of the container properties and composition Container suitability5 Manufacturing and controls Sterilization validation CCIT data Confirmatory batch data, including release and stability data (accelerated and real time), and data to support sterility assurance PAS BLA: Changes to an Approved Application for Specified Biotechnology and Specified Synthetic Biological Products Section 3.2.P.7. of the Appendix in Chemistry, Manufacturing, and Controls Changes to an Approved Application: Certain Biological Products continued Contains Nonbinding Recommendations Table B, continued Proposed Change Recommended Information to Support the Change Recommended Reporting Category Reference to Current Guidance1 Specific Considerations for Reporting Category Change in stopper rubber/elastomer material6 Description of new stopper Composition Closure suitability7 Manufacturing and controls CCIT data Confirmatory batch data, including release and stability data (accelerated and real time), and data to support sterility assurance PAS BLA: Changes to an Approved Application for Specified Biotechnology and Specified Synthetic Biological Products Section 3.2.P.7. of the Appendix in Chemistry, Manufacturing, and Controls Changes to an Approved Application: Certain Biological Products Change in stopper dimensions Confirmatory batch data, including release and stability data (accelerated and real time), and data to support sterility assurance CCIT data CBE-30 Same as above continued Contains Nonbinding Recommendations Table B, continued Proposed Change Recommended Information to Support the Change Recommended Reporting Category Reference to Current Guidance1 Specific Considerations for Reporting Category Changes in how the stopper is supplied (e.g., unprocessed, RTS, and RTU) Sterilization and depyrogenation validation Confirmatory batch data, including data to support sterility assurance CBE-30 Section 3.2.P.7. of the Appendix in Chemistry, Manufacturing, and Controls Changes to an Approved Application: Certain Biological Products Changes to an Approved Application for Specified Biotechnology and Specified Synthetic Biological Products For certain biological products, FDA may consider AR depending on the circumstances of the change (e.g., change is occurring at a vendor that provides pre- processed stoppers) * PAS = prior approval supplement; BLA = biologics license application; CCIT = Container Closure Integrity Test; AR = annual report; CBE-30 = changes being effected in 30 days; RTS = ready to sterilize; RTU = ready to use • Accelerated and real time refers to batch stability data from accelerated and long-term studies, respectively. 1 We update guidances periodically. For the most recent version of a guidance, check the FDA guidance web page at https://www.fda.gov/regulatory- information/search-fda-guidance-documents. 2 This change can be reported in an annual report if there is no change in the product-contact material or dimensions (size and shape) per 3.2.P.7 of the Appendix in the guidance for industry Chemistry, Manufacturing, and Controls Changes to an Approved Application: Certain Biological Products. 3 United States Pharmacopeia (USP) General Chapter <660> Glass Containers Used in Pharmaceutical Packaging/Delivery Systems, and USP General Chapter <1660> Evaluation of the Inner Surface Durability of Glass Containers. 4 Some of these identified changes, depending on the circumstances, may be more appropriately submitted as an original application instead of as supplements. This type of change may also warrant a labeling change supplement to account for a new presentation. Application holders should follow existing FDA guidance. Applicants can consult the appropriate review division within CDER or CBER if there are questions. 5 Information about the suitability of proposed glass with respect to protection (e.g., container integrity for sterility), safety (e.g., extractables and leachables) and performance. Application holders should refer to USP General Chapter <660> and USP General Chapter <1660> for further information. Contains Nonbinding Recommendations 6 When alternate suppliers of stoppers are proposed, and if there are differences in stopper properties or manufacturing processes changes between the currently approved and proposed supplier, because of the increased risk to quality, a higher reporting category — PAS — is warranted. However, if the differences in stopper properties and manufacturing processes are minimal then a lower reporting category may be considered. 7 Information about the suitability of proposed stopper with respect to protection (e.g., container integrity for sterility), safety (e.g., extractables and leachables) and performance. Application holders should refer to USP General Chapter <381> Elastomeric Closure for Injections, for additional information. Contains Nonbinding Recommendations Table C: Changes to the Source or Site of Manufacture for Glass Vials and Stoppers: New Drug Applications/Abbreviated New Drug Applications* Proposed Change Recommended Information to Support the Change Recommended Reporting Category Reference to Current Guidance1 Specific Considerations for Reporting Category Site of vial or stopper manufacture or processing (no change in supplier) Name and address of the new site Comparative information on the CCS between the old and the new source Commitment to place batches on stability AR Section VI.A. of Changes to an Approved NDA or ANDA (April 2004) Site of vial or stopper sterilization Name and address of the new site Validation data to support the vial/stopper sterilization AR (when the process is not materially different from that provided for in the approved application) Section VI.D.4. of Changes to an Approved NDA or ANDA Site of vial or stopper testing Name and address of the new site Full description of the testing to be performed by the new facility CBE-30 Section VI.C.1.d. of Changes to an Approved NDA or ANDA PAC-ATLS: Postapproval Changes — Analytical Testing Laboratory Sites (April 1998) * AR = annual report; CBE-30 = changes being effected in 30 days 1 We update guidances periodically. For the most recent version of a guidance, check the FDA guidance web page at https://www.fda.gov/regulatory- information/search-fda-guidance-documents. Contains Nonbinding Recommendations Table D: Changes to the Source or Site of Manufacture for Glass Vials and Stoppers: Biologics License Applications* Proposed Change Recommended Information to Support the Change Recommended Reporting Category Reference to Current Guidance1 Specific Considerations for Reporting Category Site of vial or stopper manufacture or processing (no change in supplier) Name and address of the new site Comparative information on the CCS between the old and the new source Commitment to place batches on stability AR Section 3.2.P.7. of the ## Appendix in: Chemistry, Manufacturing, and Controls Changes to an Approved Application: Certain Biological Products (June 2021) Changes to an Approved Application for Specified Biotechnology and Specified Synthetic Biological Products (July 1997) For certain biological products, a higher reporting category may be appropriate if vial or stopper manufacturing or processing will be done by the drug product manufacturer continued Contains Nonbinding Recommendations Table D, continued Proposed Change Recommended Information to Support the Change Recommended Reporting Category Reference to Current Guidance1 Specific Considerations for Reporting Category Site of vial or stopper sterilization Name and address of the new site Validation data to support the vial/stopper sterilization CBE-30 Section 3.2.P.7. of the ## Appendix in: Chemistry, Manufacturing, and Controls Changes to an Approved Application: Certain Biological Products Section 5.2 of the Appendix in CMC Postapproval Manufacturing Changes for Specified Biological Products To Be Documented in Annual Reports (December 2021) Changes to an Approved Application for Specified Biotechnology and Specified Synthetic Biological Products For certain biological products, FDA may consider AR depending on the circumstances of the change (e.g., vendor provides pre- sterilized stoppers and is changing site of sterilization). Site of vial or stopper testing Name and address of the new site Full description of the testing to be performed by the new facility AR CMC Postapproval Manufacturing Changes for Specified Biological Products To Be Documented in Annual Reports * AR = annual report; CBE-30 = changes being effected in 30 days 1 We update guidances periodically. For the most recent version of a guidance, check the FDA guidance web page at https://www.fda.gov/regulatory-information/search-fda- guidance-documents. Contains Nonbinding Recommendations Table E: Changes to the Manufacturing or Processing of Glass Vials and Stoppers: New Drug Applications/Abbreviated New Drug Applications* Proposed Change Recommended Information to Support the Change Recommended Reporting Category Reference to Current Guidance1 Specific Considerations for Reporting Category Changes in vial sterilization or depyrogenation method (e.g., changing from moist to dry heat) Validation data to support the sterilization or depyrogenation method change Extractables and leachables data Accelerated and real time• stability data PAS Section VII.B.2. of Changes to an Approved NDA or ANDA (April 2004) Changes in vial sterilization or depyrogenation process parameters Validation data to support the sterilization/depyrogenation process change CBE-30 Section VII.C.1.d. of Changes to an Approved NDA or ANDA Stopper washing process Validation data to support the depyrogenation process change CBE-30 Section VII.C.1.a. of Changes to an Approved NDA or ANDA Stopper siliconization process CCIT data if a new coating is used Extractables and leachables data Accelerated and real time stability data PAS Section IX.B.4. of Changes to an Approved NDA or ANDA continued Contains Nonbinding Recommendations Table E, continued Proposed Change Recommended Information to Support the Change Recommended Reporting Category Reference to Current Guidance1 Specific Considerations for Reporting Category Changing the method of stopper sterilization (e.g., from moist heat to irradiation) Validation data to support the sterilization/depyrogenation process change Extractables and leachables data Accelerated and real time stability data PAS Section VII.B.2. of Changes to an Approved NDA or ANDA Stopper sterilization process parameters Validation data to support the sterilization/depyrogenation process change CBE-30 Section VII.C.1.a. of Changes to an Approved NDA or ANDA * PAS = prior approval supplement; CBE-30 = changes being effected in 30 days; CCIT = Container Closure Integrity Test • Accelerated and real time refers to batch stability data from accelerated and long-term studies, respectively. 1 We update guidances periodically. For the most recent version of a guidance, check the FDA guidance web page at https://www.fda.gov/regulatory- information/search-fda-guidance-documents. Contains Nonbinding Recommendations Table F: Changes to the Manufacturing or Processing of Glass Vials and Stoppers: Biologics License Applications* Proposed Change Recommended Information to Support the Change Recommended Reporting Category Reference to Current Guidance1 Specific Considerations for Reporting Category Changes in vial sterilization or depyrogenation method (e.g., changing from moist to dry heat) Validation data to support the sterilization or depyrogenation method change Extractables and leachables data Accelerated and real time• stability data PAS Changes to an Approved Application for Specified Biotechnology and Specified Synthetic Biological Products (July 1997)2 Changes in vial sterilization or depyrogenation process parameters Validation data to support the sterilization or depyrogenation process change CBE-30 Section 3.2.P.7. of the ## Appendix in: Chemistry, Manufacturing, and Controls Changes to an Approved Application: Certain Biological Products (June 2021) Changes to an Approved Application for Specified Biotechnology and Specified Synthetic Biological Products For certain biological products, FDA may consider AR depending on the circumstances of the change (e.g., vial vendor is changing the sterilization or depyrogenation process parameters) continued Contains Nonbinding Recommendations Table F, continued Proposed Change Recommended Information to Support the Change Recommended Reporting Category Reference to Current Guidance1 Specific Considerations for Reporting Category Stopper washing process Depyrogenation validation data to support the stopper washing process change CBE-30 Section 5.2 of the Appendix in CMC Postapproval Manufacturing Changes for Specified Biological Products To Be Documented in Annual Reports (December 2021) Section 3.2.P.7. of the ## Appendix in: Chemistry, Manufacturing, and Controls Changes to an Approved Application: Certain Biological Products Changes to an Approved Application for Specified Biotechnology and Specified Synthetic Biological Products For certain biological products, FDA may consider AR depending on the circumstances of the change (e.g., vendor provides pre- washed stoppers and is changing the washing process) continued Contains Nonbinding Recommendations Table F, continued Proposed Change Recommended Information to Support the Change Recommended Reporting Category Reference to Current Guidance1 Specific Considerations for Reporting Category Stopper siliconization process CCIT data if a new coating is used Extractables and leachables data Accelerated and real time stability data CBE-30 Section 3.2.P.7. of the ## Appendix in: Chemistry, Manufacturing, and Controls Changes to an Approved Application: Certain Biological Products Changes to an Approved Application for Specified Biotechnology and Specified Synthetic Biological Products For certain biological products, FDA may consider AR depending on the circumstances of the change (e.g., vendor provides pre- siliconized stoppers and is changing the siliconization process) Changing the method of stopper sterilization (e.g., from moist heat to irradiation) Validation data to support the stopper sterilization method change Extractables and leachables data Accelerated and real time stability data PAS Changes to an Approved Application for Specified Biotechnology and Specified Synthetic Biological Products3 For certain biological products, FDA may consider AR depending on the circumstances of the change (e.g., vendor is changing the sterilization method) continued Contains Nonbinding Recommendations Table F, continued Proposed Change Recommended Information to Support the Change Recommended Reporting Category Reference to Current Guidance1 Specific Considerations for Reporting Category Stopper sterilization process parameters Validation data to support the stopper sterilization process change CBE-30 Section 3.2.P.7. of the ## Appendix in: Chemistry, Manufacturing, and Controls Changes to an Approved Application: Certain Biological Products Changes to an Approved Application for Specified Biotechnology and Specified Synthetic Biological Products For certain biological products, FDA may consider AR depending on the circumstances of the change (e.g., vendor provides pre- sterilized stoppers and is changing the sterilization process) * PAS = prior approval supplement; CBE-30 = changes being effected in 30 days; AR = annual report; CCIT = Container Closure Integrity Test • Accelerated and real time refers to batch stability data from accelerated and long-term studies, respectively. 1 We update guidances periodically. For the most recent version of a guidance, check the FDA guidance web page at https://www.fda.gov/regulatory- information/search-fda-guidance-documents. 2 See also 21 CFR 601.12(b)(2)(vi). 3 Ibid. --- ### Document: FDA ParametricRelease Complete (FDA) # FDA Guidance for Industry: Submission of Documentation for Parametric Release of Drug Products Terminally Sterilized by Moist Heat (2010) Guidance for Industry Submission of Documentation in Applications for Parametric Release of Human and Veterinary Drug Products Terminally Sterilized by Moist Heat Processes U.S. Department of Health and Human Services Food and Drug Administration Center for Drug Evaluation and Research (CDER) Center for Veterinary Medicine (CVM) Center for Biologics Evaluation and Research (CBER) February 2010 CMC Guidance for Industry Submission of Documentation in Applications for Parametric Release of Human and Veterinary Drug Products Terminally Sterilized by Moist Heat Processes Additional copies are available from: Office of Communications Division of Drug Information Center for Drug Evaluation and Research Food and Drug Administration 10903 New Hampshire Avenue Bldg. 51, rm. 2201 Silver Spring, MD 20993-0002 (Tel) 301-796-3400 http://www.fda.gov/Drugs/GuidanceComplianceRegulatoryInformation/Guidances/default.htm and/or Communications Staff, HFV-12 Center for Veterinary Medicine Food and Drug Administration 7519 Standish Place, Rockville, MD 20855 (Tel) 240-276-9300 http://www.fda.gov/AnimalVeterinary/GuidanceComplianceEnforcement/GuidanceforIndustry/default.htm and/or Office of Communication, Outreach, and Center for Biologics Evaluation and Research Food and Drug Administration 1401 Rockville Pike, Suite 200N, Rockville, MD 20852-1448 (Tel) 800-835-4709 or 301-827-1800 ocod@fda.hhs.gov http://www.fda.gov/BiologicsBloodVaccines/GuidanceComplianceRegulatoryInformation/Guidances/default.htm U.S. Department of Health and Human Services Food and Drug Administration Center for Drug Evaluation and Research (CDER) Center for Veterinary Medicine (CVM) Center for Biologics Evaluation and Research (CBER) February 2010 CMC Contains Nonbinding Recommendations TABLE OF CONTENTS I. INTRODUCTION............................................................................................................. 1 II. BACKGROUND ............................................................................................................... 2 III. CONTENT OF SUBMISSIONS FOR PARAMETRIC RELEASE ............................ 3 A. Control Strategy for the Terminal Sterilization Program .........................................................4 B. Risk Assessment, Process Understanding, and Prior Knowledge .............................................5 C. Documentation for Parametric Release Process .........................................................................5 IV. FILING REQUIREMENTS ............................................................................................ 6 V. REFERENCES.................................................................................................................. 7 Contains Nonbinding Recommendations Guidance for Industry1 Submission of Documentation in Applications for Parametric Release of Human and Veterinary Drug Products Terminally Sterilized by Moist Heat Processes This guidance represents the Food and Drug Administration's (FDA's) current thinking on this topic. It does not create or confer any rights for or on any person and does not operate to bind FDA or the public. You can use an alternative approach if the approach satisfies the requirements of the applicable statutes and regulations. If you want to discuss an alternative approach, contact the FDA staff responsible for implementing this guidance. If you cannot identify the appropriate FDA staff, call the appropriate number listed on the title page of this guidance. I. INTRODUCTION This guidance provides recommendations to applicants on information to include in support of parametric release for sterile products2 terminally sterilized by moist heat when submitting a new drug application (NDA), abbreviated new drug application (ANDA), new animal drug application (NADA), abbreviated new animal drug application (ANADA), biologics license application (BLA), or supplement or other postmarketing report. the market.3, 4 In many cases, the requirements for batch release are fulfilled by conducting a sterility test on finished units drawn from the batch. Parametric release is defined as a sterility assurance release program where demonstrated control of the sterilization process enables a firm to use defined critical process controls, in lieu of the sterility test, to fulfill the intent of 21 CFR 211.165(a), and 211.167(a).5 Under this strategy, market release of terminally sterilized products can be based upon meeting the defined sterilization parameters and not on performing an approved sterility test. Meeting the requirements of the parametric release process can provide greater assurance that a batch meets the sterility requirement than can be achieved with a sterility test of finished units drawn from the batch. 1 This guidance has been prepared by the Office of Pharmaceutical Science in the Center for Drug Evaluation and Research (CDER) in cooperation with CDER’s Office of Compliance, the Center for Veterinary Medicine (CVM), and the Center for Biologics Evaluation and Research (CBER) at the Food and Drug Administration. 2 The term product includes final products that are regulated by CDER, CVM, and CBER. 3 See 21 CFR 314.50(d)(1)(ii)(a) or 21 CFR 514.1(b)(5)(vii)(b). 4 See 21 CFR 211.167(a) for drug products or 21 CFR 610.12 for biologic products. In addition, refer to United States Pharmacopeia (USP) General Chapters: <1> (Injections), <71> (Sterility), and <1041> (Biologics). Short- lived radiopharmaceuticals, including positron emission tomography (PET) drugs, are subject to sterility testing; however, they may be released prior to completion of this test (21 CFR 211.165(a)). 5 For information on how current good manufacturing practices will be applied for products subject to parametric release that are within the scope of this guidance, see the FDA Compliance Policy Guide (CPG) 460.800. Contains Nonbinding Recommendations This guidance does not provide information on procedures, studies, or data concerning efficacy and qualification/validation of moist heat sterilization processes. This guidance also does not provide information on sterility assurance validation programs. However, you may find information relating to such topics in the Agency’s guidance for industry on Submission of Documentation for Sterilization Process Validation in Applications for Human and Veterinary Drug Products.6, 7 Current Good Manufacturing Practices (CGMP) requirements for process validation are found at 21 CFR 211.100 and, for sterile products in particular, at 21 CFR 211.113(b). Adherence to CGMPs is required for all marketed products. The principles in the guidance may also be applicable to products sterilized by other terminal sterilization processes, such as radiation sterilization, which may be suitable for parametric release. For these types of applications, we recommend the applicant discuss with the review division whether applying the guidance would be appropriate. FDA's guidance documents, including this guidance, do not establish legally enforceable responsibilities. Instead, guidances describe the Agency's current thinking on a topic and should be viewed only as recommendations, unless specific regulatory or statutory requirements are cited. The use of the word should in Agency guidances means that something is suggested or recommended, but not required. II. BACKGROUND Sterility testing by cultivation of finished units drawn from the batch is limited in its ability to detect contamination because of the following: (1) the small number of samples required for testing, which restricts the ability to capture those microorganisms dispersed in a large volume, and (2) the limited ability of the prescribed culture media to stimulate growth of all potential microorganisms. Typically, these tests will detect only major errors in the manufacturing process that result in contamination of a large number of product units. However, data derived from in-process controls of a validated terminal sterilization process can provide more accurate information regarding product sterility because the probability of product bioburden surviving the sterilization process in any single unit of a product can be calculated to be less than one in a million. Parametric release allows manufacturers to replace sterility testing of samples drawn from the finished product as a release criterion with acceptance criteria for the control of identified process parameters. These parameters, called critical parameters, are critical to a successful sterilization process and are based on an in-depth knowledge of the process, the product, the 6 This guidance outlines the submission documentation for microbiological product quality of sterile products. 7 CDER guidance documents can be found on the Internet at http://www.fda.gov/Drugs/GuidanceComplianceRegulatoryInformation/Guidances/default.htm. We update guidances periodically. To make sure you have the most recent version of a guidance, check the CDER guidance Web site. CVM guidance documents can be found at http://www.fda.gov/AnimalVeterinary/GuidanceComplianceEnforcement/GuidanceforIndustry/default.htm, and CBER guidance documents can be found at http://www.fda.gov/BiologicsBloodVaccines/GuidanceComplianceRegulatoryInformation/Guidances/default.htm. Contains Nonbinding Recommendations effects of the sterilization process on the product itself, and any microorganisms that become associated with the product during the manufacturing process. Parametric release of the batch is then based on documented evidence of the control of critical parameters, removing the need to test samples drawn from the finished product. A sterilization load monitor,8 either in the form of a physical, chemical (ANSI 2008), or biological indicator, is included with each load to satisfy the requirement for a laboratory test.9 In addition, the sterilization load monitor is always considered a critical process parameter. A successful load monitor result, the meeting of the acceptance criteria of the critical parameters, and having a well validated sterility assurance program demonstrate that there is a state of control of the manufacturing process for the product. The load monitor(s) should be placed in appropriate positions to indicate that the load was exposed to a sterilization process which was measured and recorded for conformance with defined criteria for parametric release. This position(s) is determined based on the evaluation of development and qualification data. The location and number of monitors should be described and justified in the application. Alternative procedures for demonstrating that a load or part of a load was exposed to a sterilization process should be discussed with the review division(s) prior to submitting a plan for parametric release. FDA conducts scientific evaluation of the parametric release program as part of a cooperative effort among our review staff, compliance staff, and field investigators. FDA has accepted the practice of parametric release for drug products terminally sterilized by moist heat since 1985. Parametric release, described in the International Conference on Harmonisation (ICH) Q6A (ICH 2000),10 is endorsed by regulatory and/or pharmaceutical manufacturing groups in the US (PDA 1999, USP 2009), EU (PIC/S 2007, EMEA 2001), and Japan (Sasaki 2002). III. CONTENT OF SUBMISSIONS FOR PARAMETRIC RELEASE Section IV describes what submissions are required to obtain approval for parametric release.11 The approval of parametric release practices is based on an assessment of the applicant’s proposed critical process parameters and how they are controlled. Demonstrated reliability of the production terminal sterilization cycle, microbiological control, and monitoring and control of production cycle parameters within established validated limits are part of this assessment. The terminal sterilization process for the product proposed for parametric release should be validated according to the Agency’s guidance for industry on Submission of Documentation for Sterilization Process Validation in Applications for Human and Veterinary Drug Products.12 8 See section III. C., bullet 5. 9 See 21 CFR 211.167(a). 10 See footnote 7. 11 See 21 CFR 314.50(d)(1)(ii)(a) and 21 CFR 314.70(b)(2)(iii) for human drug products; 21 CFR 514.1(b)(5)(vii)(b) and 21 CFR 514.8(b)(2)(ii)(C) for veterinary drug products; or 21 CFR 601.2(a) for biologic products. 12 See footnotes 6 and 7. Contains Nonbinding Recommendations FDA approval of the parametric release program will be based on how well the firm has addressed the risks to product sterility. A risk assessment statement consistent with the principles of ICH Q9 (ICH 2006) should be provided that describes the following: • Current strategies for control of the terminal sterilization program; • Risk that these strategies might fail to ensure sterility; and • How prior manufacturing experience and knowledge were incorporated into the risk assessment.13 A. Control Strategy for the Terminal Sterilization Program A control strategy is used to ensure that the acceptance criteria of the parametric release process and terminal sterilization cycle are met in order to ensure product sterility. The control strategy should include the following: • The rationale for the methods implemented to monitor and control the terminal sterilization process used for the product release (the critical process parameters); • The rationale for the selection of critical process parameter(s); • A description of the acceptance criteria for parametric release; • A description of the drug product and container closure system (including secondary packaging, as applicable) that will be part of the parametric release program; • A description of the proposed production loading patterns and verification that they are within the validated limits for the terminal sterilization cycle, or a statement that they have not changed since last approved and validated (as applicable); and • A description of the microbiological monitoring plan for the product and components prior to terminal sterilization or a statement that the plan has not changed since last validated. Spore detection and heat resistance studies should be emphasized for bioburden based sterilization cycles. If you are referencing information previously submitted to meet these recommendations, it should include the application number and submission date, and any other relevant citations to the Agency’s records where the information can be found.14 13 Knowledge management and quality risk management can be used to continually improve manufacturing capabilities throughout the life cycle for a terminal sterilization program. 14 See 21 CFR 314.50(g)(1) or 21 CFR 601.2. Contains Nonbinding Recommendations B. Risk Assessment, Process Understanding, and Prior Knowledge Successful parametric release systems are based on the reliability of the control strategy of the sterility assurance program. We recommend that your risk assessment focus on the risk of failure to achieve the minimum required probability of a non-sterile unit for each unit of every batch. The risk assessment should include the following: • Consistency of performance of the terminal sterilization cycle within the validated limits. • A discussion of risk to the sterility of the product relative to the following: (1) the production terminal sterilization cycle, (2) the production loading patterns, (3) the container closure system (including secondary packaging), and (4) any potential contamination risks from the environment (as appropriate). For an approved application, you should indicate any changes to the above items and provide an assessment of the risk to the sterility of the product associated with those changes. For example, although the established minimum sterilization time cannot be lowered, the maximum sterilization time can be increased if the appropriate stability data are provided to support the increase. • Experience with the proposed or similar product (and container closure system) and proposed or similar sterilization process, the overall risks to sterility, and the steps you have taken to assess and control these risks. For new products, prior knowledge from developmental and registration/exhibit batches may suffice. • A discussion of your overall prior knowledge and production and testing experience relevant to the drug product that will be subject to parametric release. C. Documentation for Parametric Release Process The following information specific to the proposed parametric release process should also be included in your submission: • A citation to a complete and detailed description of the current relevant terminal sterilization cycle. • Identification of the critical process parameters (process/cycle parameters and appropriate load monitors essential for product release) for the product(s) proposed for parametric release, including the minimum and maximum limits for these critical parameters. The critical process parameters should be within the limits that have been validated and approved for sterility assurance of the subject product(s). • Acknowledgement that adherence to the critical parameters of the parametric release program will substitute for the performance of a sterility test as the primary release criterion for the product and that sterility test results from the finished product will not be used to overrule any failure to meet the acceptance criteria of the parametric release Contains Nonbinding Recommendations program. In the event of failure, the specific sterilizer load will be rejected by the quality control unit and will not be released unless there is a provision for reprocessing. • Acknowledgement that regardless of the batch release technique used, any specimen tested according to the reference test method for sterility (e.g., compendium or FDA regulations) will meet the criteria for sterility (such as during testing for stability or postmarketing investigations). • A description of the sterilization load monitor that indicates the following: (1) the type of monitor being proposed, (2) how the load monitor will be used and analyzed, (3) what functions are being measured by the monitor, and (4) the rationale for the location of the monitor. Additionally, for indirect monitors, we recommend that you include a statement justifying the classification of the indirect indicator that you are using as defined by the American National Standard Institute (ANSI 2008). In certain circumstances a Class 3 indicator may be appropriate; however, a Class 5 indicator is recommended for most situations. • Documentation of the control system to verify exposure of the load to the sterilization process. • Revision of the certificates of analysis or batch release records for each product subject to parametric release to indicate that parametric release is now the method used to provide assurance of the requirement of sterility. We recommend that you provide a reference to show the link between batch release criteria and the commitments in the application. IV. FILING REQUIREMENTS To request parametric release in an original application submission, the request should include information specific to parametric release along with sterilization validation information and product release criteria. For changes to an approved application, the request for parametric release should be submitted in a prior approval supplement under 21 CFR 314.70, 21 CFR 601.12 or 21 CFR 514.8(b)(2). The change to parametric release requires FDA approval before its implementation. If the applicant has current experience using parametric release with a comparable sterilization cycle at the same manufacturing site, and the proposed product's manufacturing process fits into the same validation protocol for parametric release (e.g., container closure system, load patterns, cycle process parameters, and cycle acceptance criteria), then the applicant should meet the filing requirements with a special report for a human drug product,15 or an annual report for a veterinary drug product16 or a biologic product.17 If your product fits into one of these filing categories, contact the review division for your product to verify submission requirements. 15 21 CFR 314.81(b)(3)(ii) 16 21 CFR 514.8 (b)(4) 17 21 CFR 601.12(d) Contains Nonbinding Recommendations V. REFERENCES American National Standard Institute (ANSI), Association for the Advancement of Medical Instrumentation (AAMI), International Organization for Standardization (ISO) 15882, 2008, Sterilization of Health Care Products-Chemical Indicators-Guidance for Selection, Use and Interpretation of Results. The European Agency for the Evaluation of Medicinal Product (EMEA), 2001; Committee for Proprietary Medicinal Products: Note for Guidance on Parametric Release, March 2001, CPMP/QWP/3015/99. Food and Drug Administration, 1987, Parametric Release - Terminally Heat Sterilized Drug Products, Compliance Policy Guide (CPG) 460.800 (CPG 7132a.14), October 2, 1987. International Conference Harmonisation (ICH), 2000, Guidance on Q6A Specifications: Test Procedures and Acceptance Criteria for New Drug Substances and New Drug Products: Chemical Substances, Guidance for Industry, Federal Register, Vol. 65, No. 251, December 29, 2000. ICH, 2006, Q9 Quality Risk Management, Guidance for Industry, Federal Register, Vol. 71, No. 106, June 2006. ICH, 2009, Q10 Pharmaceutical Quality System, Guidance for Industry, Federal Register, Vol. 74, No. 66, April 2009. PDA Journal of Pharmaceutical Science and Technology, Technical Report No. 30: Parametric Release of Pharmaceuticals Terminally Sterilized by Moist Heat, Supplement, Volume 53, Number 4, July-August 1999 Pharmaceutical Inspection Convention/Pharmaceutical Inspection Co-operation Scheme (PIC/S): Guidance on Parametric Release, 2007, PI 005-3, September 25, 2007. Sasaki, T., 2002, Parametric Release for Moist Heated Pharmaceutical Products in Japan, PDA Journal of GMP and Validation in Japan, Volume 4, Number 1. United States Pharmacopeia (USP) 32-NF, General Chapter <1222> Terminally Sterilized Pharmaceutical Products-Parametric Release, 2009. --- ### Document: FDA ProcessInspection Complete (FDA) # FDA Compliance Program Guidance Manual 7356.002A: Sterile Drug Process Inspections (2015): Sterile Drug Process Inspections — FDA CPGM 7356.002A ===== PAGE 1 ===== Page 1 of 38 FOOD AND DRUG ADMINISTRATION COMPLIANCE PROGRAM GUIDANCE MANUAL PROGRAM 7356.002A CHAPTER 56 – DRUG QUALITY ASSURANCE SUBJECT: STERILE DRUG PROCESS INSPECTIONS Revision Note: Program revised 09/11/2015 to update implementation date, completion date, organizational/procedural changes and program contacts. IMPLEMENTATION DATE September 11, 2015 COMPLETION DATE September 11, 2016 DATA REPORTING PRODUCT CODES PRODUCT/ASSIGNMENT CODES Industry codes 54, 56 and 60-66 inclusive Domestic / Foreign Inspections: 56002A (Full Inspection) 56002I (Abbreviated Inspection) Related PACs 56002 56002C 56002M FIELD REPORTING REQUIREMENTS: Establishment Inspection Reports (EIRs) are to be created and filed electronically using the specific module in TurboEIR or replacement system that is accessible to both ORA and CDER. For inspections of routine commercial manufacturing classified as Official Action Indicated (OAI) due to failure to comply with 21 CFR Part 210 and 211 Current Good Manufacturing Practice (CGMP) as they apply to sterile drug process inspections, submit advisory, administrative, or judicial action recommendations via MARCS-CMS in accordance with the Regulatory Procedures Manual (RPM). Districts should immediately report significant issues according to current FACTS, Panorama and CMS procedures. This includes promptly filing and changing OAI notifications. During an inspection, if you obtain information pertaining to inadequate adverse drug experience (ADE) reporting, unapproved drug issues, or post-approval reporting violations (application supplements, Field Alert Reports (FARs), etc.), report in accordance with directions provided in the applicable compliance programs and under separate captions in the EIR. Data system information about these inspectional activities should be reported under separate Program Assignment Codes (PACs). Expansion of coverage under these programs into a CGMP inspection should be reported under this compliance program. ===== PAGE 2 ===== PROGRAM 7356.002A PAGE 2 of 38 The Districts are requested to use this compliance program for all sterile drug process inspections. NOTE: Districts should assure that each operation performed by direction of this program circular is entered against the correct Product Code and Program/Assignment Code (P/AC). ===== PAGE 3 ===== PROGRAM 7356.002A PAGE 3 of 38 TABLE OF CONTENTS PART I BACKGROUND ................................................................................................... 4 PART II IMPLEMENTATION ............................................................................................. 5 2.1 Objective....................................................................................................... 5 2.2 Program Management Instructions .............................................................. 5 A. Strategy ............................................................................................... 5 B. Inspection Planning............................................................................. 6 C. Profile Reporting ................................................................................. 6 PART III INSPECTIONAL ................................................................................................... 7 3.1 Types of Sterilization .................................................................................... 7 A. Terminal sterilization ........................................................................... 7 B. Aseptic processing .............................................................................. 7 3.2 Reporting ...................................................................................................... 8 3.3 Inspection Approaches................................................................................. 9 3.4 System Inspection Coverage ..................................................................... 11 3.5 Quality System ........................................................................................... 11 3.6 Facilities and Equipment System ............................................................... 13 A. Facilities ............................................................................................ 13 B. Equipment ......................................................................................... 14 3.7 Materials System ........................................................................................ 19 3.8 Production System ..................................................................................... 21 3.9 Packaging and Labeling System ................................................................ 27 3.10 Laboratory Control System......................................................................... 27 3.11 Sampling..................................................................................................... 29 PART IV ANALYTICAL..................................................................................................... 30 PART V REGULATORY/ADMINISTRATIVE STRATEGY .............................................. 31 PART VI REFERENCES, ATTACHMENTS AND PROGRAM CONTACTS ................... 33 6.1 References ................................................................................................. 33 6.2 Attachments................................................................................................ 34 6.2 Contacts ..................................................................................................... 34 PART VII CENTER RESPONSIBILITIES .......................................................................... 36 ATTACHMENT A .................................................................................................................A [end Cover Page] ===== PAGE 4 ===== PROGRAM 7356.002A PAGE 4 of 38 PART I - BACKGROUND This program covers the manufacture and testing of all sterile drug products, including drugs that are sterilized by filtration or other means and aseptically processed, and drug products that are terminally sterilized. The type of products covered by this program include sterile bulk drugs, ophthalmic drugs, otic dosage forms, small volume parenteral (SVS) products for small molecule and licensed biological therapeutic drug products, large volume parenteral (LVP) products, and any other drug products required to be sterile or labeled as sterile. Center for Biologics Evaluation and Research (CBER) regulated products and veterinary drug products are excluded from coverage under this program. The guidance information in this program is tailored to sterile manufacturing operations and should be used in conjunction with the Compliance Program for Drug Manufacturing Inspections (CP 7356.002). In 2004, Food and Drug Administration (FDA) published the Guidance for Industry Sterile Drug Products Produced by Aseptic Processing-- Current Good Manufacturing Practice, which is referred to throughout this Compliance Program as FDA’s “2004 Aseptic Processing Guidance.” The document represents FDA’s current thinking on Current Good Manufacturing Practices (CGMPs) for aseptically processed drugs. The Guidance for Industry does not establish mandatory requirements and should not be referred to as the justification for an inspectional observation. Justification for inspectional observations originates from the CGMP regulations, 21 CFR Parts 210 and 211. Manufacturers who follow the 2004 Aseptic Processing Guidance are generally considered compliant with CGMP regulations. However, alternate approaches may be used if such approaches satisfy the requirements of 21 CFR Parts 210 and 211. For technical questions and unusual circumstances encountered during an inspection, investigators are encouraged to contact their District, ORA Office of Medical Products and Tobacco Operations/Division of Medical Products and Tobacco Program Operations and/or CDER for consultation. For questions concerning microbiological analysis, sterility and related sampling concerns, contact ORA Office of Regulatory Science/Medical Products and Tobacco Scientific Staff. [end Part I] ===== PAGE 5 ===== PROGRAM 7356.002A PAGE 5 of 38 PART II - IMPLEMENTATION ### 2.1 OBJECTIVES The primary objective of this program is to provide guidance for conducting inspections of manufacturers of sterile bulk1 and sterile finished dosage drug products to determine compliance with the Food, Drug, and Cosmetic Act and the Current Good Manufacturing Practice Regulations (CGMPs), Title 21, CFR Parts 210 and 211. Other objectives include: • Obtain information on operations impacting on sterility, to identify areas for improvement and correction. • Evaluate current good manufacturing practices in the sterile drug industry. • Initiate appropriate action against manufacturers observed to be out of compliance. ### 2.2 PROGRAM MANAGEMENT INSTRUCTIONS A. STRATEGY (1) Inspection of Systems Inspections of drug manufacturers should be made and reported using the system definitions and organization in this compliance program. Focusing on systems will increase inspection efficiency because the systems are often applicable to multiple profile classes. The selection of the system(s) for coverage will be made by the District Office based on the firm’s specific operation, previous coverage, compliance history, or other priorities determined by the District Office. The inspection should normally result in a determination of acceptability or non-acceptability for all profile classes. Coverage of a system should be sufficiently detailed, i.e., select an example of each profile class, so that the conclusion about the system’s state-of-control applies to all the profiles classes. However, the determination that a system is adequately controlled for one profile class can be extended to another profile class(es) even if that other profile class(es) was not specifically reviewed. The lead Investigator must consider the uniqueness of the various manufacturing situations at the plant and use their best judgment when selecting profile classes to review. Selecting specific areas unique functions within a system will be at the discretion of the lead Investigator. The options for system coverage are described in CPGM 56002. Any given inspection need not cover every system. See Part III - Inspectional. Complete inspection of one system may necessitate further follow up of some items within the activities of another system(s) to fully document the findings. Such follow up does not constitute full coverage of the other system (and cannot be reported as such in FACTS); nor does that follow up obligate the investigator to perform full coverage of the other system. 1 “Sterile bulk” refers to sterile active pharmaceutical ingredients (APIs). ===== PAGE 6 ===== PROGRAM 7356.002A PAGE 6 of 38 (2) Inspectional Scope Inspections of sterile product drug manufacturers are performed as either Full Inspections or Abbreviated Inspections using the systems strategy outlined in Part II –Implementation, of Compliance Program 7356.002, Drug Manufacturing Inspections. See Part III – Inspectional, of this program for a complete discussion of the coverage requested under these inspection options. B. INSPECTION PLANNING Implement this program when sterile drug manufacturers are inspected as part of a regular statutory inspection. CDER will identify firms for inspection based on the risk-based prioritization model on annual performance goals, as part of the initiative to ensure risk-based prioritization of inspection coverage. Consider using a team approach for conducting inspections when appropriate. Utilize investigators familiar with sterile drug manufacturing and aseptic processing and consider the participation of a microbiologist with expertise in microbial controls. Specifically, • All team members should be very familiar with FDA’s Guidance for Industry Sterile Drug Products Produced by Aseptic Processing – Current Good Manufacturing Practice (September 2004). • Investigators or team members should be well qualified in sterile product manufacturing, and have completed formal training courses in parenteral drug manufacture, aseptic technique, sterilization methods, and related procedures and equipment. Microbiologists involved should have experience in sterility, endotoxin testing, and evaluation of microbial controls in manufacturing. C. PROFILE REPORTING Update all applicable profile classes in the profile screen of the FACTS coversheet based on inspection findings. The following is a list of sterile product profile classes effective at the time this program was implemented. Use the codes corresponding to the product and process type covered. PROFILE CLASS FULL DESCRIPTION LVP Large Volume Parenterals are sterile injectable drugs packaged in containers labeled as containing more than 100 mL. Most are terminally sterilized, but some can be sterilized by filtration and aseptically processed. SVT Small Volume Parenterals are sterile injectable drugs packaged in containers labeled as containing less than 100 mL that are terminally sterilized. SVS Small Volume Parenterals are sterilized by filtration and aseptically processed. SVL Small Volume Parenteral are sterilized by filtration, aseptically filled and lyophilized. SLQ Sterile liquid (other than suspensions and emulsions) SON Sterile ointment SPW Sterile powder CSS Sterile bulk drugs that are made by chemical synthesis. CFS Sterile crude drugs made by fermentation. CRX API sterile or API intermediate/NEC inorganic/mineral [end Part II] ===== PAGE 7 ===== PROGRAM 7356.002A PAGE 7 of 38 PART III - INSPECTIONAL ### 3.1 TYPES OF STERILIZATION There are two broad methods to produce a sterile drug product: • Terminal Sterilization • Aseptic Processing of sterilized unit components There are basic differences between the production of sterile drug products using aseptic processing and production using terminal sterilization. Terminal sterilization should be utilized when the product and container/closure system are able to withstand the terminal sterilization process. A. TERMINAL STERILZATION - The terminal sterilization process usually involves filling and sealing product containers under high quality environmental conditions designed to minimize microbial and particulate contamination of the product. This minimization of upstream bioburden reduces the challenge to the subsequent sterilization process. In most cases, the product, container, and closure have low bioburden, but are not sterile at the time of filling. The product is then subjected to a sterilization process in its final container. There are various methods of terminal sterilization including: • Moist Heat Sterilization • Irradiation • Ethylene Oxide (typically for assembled components/kits) Types of sterilization cycles include: 1. Overkill method: o Generally used for heat stable materials. o Designed to provide a significant level of sterility assurance regardless of the number and resistance of the actual bioburden organisms in the load. o Results in greater heat/exposure input to the product or items being sterilized. 2. Bioburden Based cycle: o Requires studies to determine the number and resistance of the microorganisms found in the product and the bioburden load of the incoming components and containers/closures. o Cycle development to destroy the microbial load, but not degrade the product. o Routine bioburden monitoring of batches and ongoing knowledge of the heat/exposure resistance of organisms found in product bioburden, container/closure bioburden and environmental monitoring samples. Reference to terminal sterilization: PDA Technical Report No. 1 (Revised 2007) Validation of Moist Heat Sterilization Processes: Cycle Design, Development, Qualification and Ongoing Control. B. ASEPTIC PROCESSING - Aseptic processing presents a higher risk of microbial contamination of the product than terminal sterilization. In an aseptic filling process, the drug product, containers and ===== PAGE 8 ===== PROGRAM 7356.002A PAGE 8 of 38 closures are sterilized separately and then brought together under an extremely high quality environmental condition designed to reduce the possibility of a non-sterile unit. Aseptic processing involves more variables than terminal sterilization. Any manual or mechanical manipulation of the sterilized drug, containers, or closures prior to or during aseptic filling and assembly poses the risk of microbial contamination. Some types of aseptic processing involve manual manipulations of sterile components, containers, and closures in addition to routine operator interventions in the critical area. Humans are a significant source of contamination in traditional aseptic processing, especially in production lines that require operators to routinely enter critical areas (Class 100, ISO 5, or Grade A) of the filling line. Aseptic processing systems based on more advanced control-based technologies, such as Restricted Access Barrier Systems (RABS) and Blow-Fill-Seal systems, are designed to reduce human interventions in the critical areas of the fill line while an isolator system completely separates the aseptic filling line from the external environment and minimizes employee interaction with the critical area. Note: More information about Isolator Technology and Blow-Fill-Seal systems is found in FDA’s 2004 Aseptic Processing Guidance. When conducting inspections of sterile drug manufacturers, it is important to cover systems and areas within systems that present the greatest risk of product contamination and/or require strict control of processing parameters. For example, if a firm has several aseptic processing lines, cover the line(s) that require the most manual manipulations in the Class 100 (ISO 5) areas. If the firm terminally sterilizes a number of products, review one that is sensitive to heat and requires a product specific (bioburden based) sterilization cycle. Note: For terminal sterilized products that are aseptically filled prior to terminal sterilization, less rigorous aseptic controls can be considered. Because of the time limitations often associated with foreign inspections, careful inspection planning is particularly important. Prioritize areas for coverage based upon their potential impact on product quality. ### 3.2 REPORTING Follow instructions in the current editions of the IOM (Investigations Operations Manual) and Guide to International Inspection and Travel in preparing the inspection report. Use Turbo EIR for all reports, both domestic and international, even if a FDA-483 was not issued or was issued outside of Turbo EIR. The “Manufacturing / Design Operations” section of the report should be organized by the systems described in this program that were covered during the inspection. Briefly summarize your review of each covered system in accordance with the key elements outlined in this Compliance Program. Add more details and supporting evidence for the systems found to be deficient. ===== PAGE 9 ===== PROGRAM 7356.002A PAGE 9 of 38 ### 3.3 INSPECTION APPROACHES If the sterile drug products to be inspected are radioactive drugs, then Compliance Program 7356.002C, Radioactive Drugs, should be followed as supplementary guidance. This program should not be used for the inspection of Positron Emission Tomography (PET) Drug. Compliance Program 7356.002P is specific for PET drugs. This program (CP 7356.002A) should also be used in conjunction with Compliance Program 7356.002M, Inspection of Licensed Biological Therapeutic Drug Products for the inspection of sterile licensed biological products. The CGMP Compliance Program 7356.002 provides general information on the system based approach to conducting inspections of drug manufacturers. It describes the six systems (Quality, Facilities and Equipment, Materials, Production, Packaging and Labeling, and Laboratory) and the two inspection options (Full Inspection and Abbreviated Inspection). It also provides guidance on when each option should be selected and discusses what “state of control” means in relation to the systems inspected. Inspections of sterile drug manufacturers are performed as either Full or Abbreviated inspections using the systems strategy outlined below. Full Inspections include surveillance or compliance inspections and provide a comprehensive evaluation of the firm’s compliance with CGMP. A Full Inspection will normally include an inspection of at least four systems, one of which must be the Quality System. Under this program, a Full Inspection should include the Facilities & Equipment, and Production Systems due to the critical role these systems play in the sterility assurance of finished product. Full Inspections (PAC 56002A) are conducted • when initial inspection of the drug firm is to be conducted; • when it is the first inspection conducted as a follow-up to a Warning Letter, regulatory action, or significant FDA 483 findings; • when information obtained during the Abbreviated Inspection reveals significant deficiencies with the firm’s practices and procedures in one or more system areas; • when there have been significant changes in the firm’s operations since the last inspection; or • for surveillance purposes at the District’s discretion because the firm has a history of recurring violations, fluctuating in and out of compliance, or when other information (samples, complaints, Field Alerts, recalls, etc.) calls into question the firm’s ability to produce quality products. Abbreviated Inspections (PAC 56002I) may be appropriate if the following two conditions are satisfied: 1. the firm has implemented a formal risk management program that assures effective design and control (including maintenance). This includes a risk mitigating design of their processing lines that incorporates a modern separation and automation approach (e.g., isolators, closed RABS), and upstream bioburden controls. The responsiveness of the firm’s quality system to potential hazards is also part of the evaluation, including whether the firm’s program provides robust ===== PAGE 10 ===== PROGRAM 7356.002A PAGE 10 of 38 daily assurance and effective consumer protection through a formal lifecycle quality risk management program that proactively uncovers and corrects issues in accord with ICH Q9. 2. the firm has a record of sustained acceptable compliance history and a strong risk management program. o the firm produces finished drug products that are terminally sterilized using robust sterilization methods. (Note: Terminal sterilization provides a much more robust process to ensure sterility); or, o the firm has implemented robust risk management that provides daily assurance through their overall design and control program; o at the start of the inspection, conduct an extensive review of sterility assurance data since the last Full Inspection. The review of media fills, sterility testing data, recalls, defect/adverse event complaints, and reports reveals no findings of sterility failure of a distributed batch, and o the firm has a record of satisfactory CGMP compliance (e.g., two consecutive NAI or no more than one VAI inspection), with no Class 1 recalls. Microbial controls and sterility assurance should be the main focus of an abbreviated sterile drug inspection. The following critical elements of each system (other than the Quality System) should be covered in an Abbreviated Inspection under this program: • Facilities and Equipment: o cleaning and disinfection o facility/equipment layout and air handling system for preventing viable and non-viable contamination o material flow o quality control of classified areas, including air pressure balance and HEPA filtration o trending data supporting the adequacy of clean room quality o documented investigation into discrepancy • Materials: o microbial and bacterial endotoxin control of incoming materials and components o quality of water supply, maintenance, qualification o operation of the systems that provide the requisite water and process gases o documented investigations into OOS, deviations, and discrepancies • Production: o observation of adequacy of operator behavior and aseptic techniques during manufacturing o production line operations and interventions o personnel training in aseptic techniques o major production line repair or maintenance issues o risk assessment on microbial and bacterial endotoxin controls, including hold times of critical steps ===== PAGE 11 ===== PROGRAM 7356.002A PAGE 11 of 38 o validation of sterilization of equipment, container-closures and supplies o media fills design and results o documented investigations into, deviations, discrepancies, and OOS results • Laboratory: o investigations into OOS, deviations, and discrepancies o test methods and controls, including adherence to validated methods o training and qualifications of laboratory personnel o trending of water system test results o systems used for recovery, identification and trending of environmental monitoring isolates ### 3.4 SYSTEM INSPECTION COVERAGE Compliance Program 7356.002, Drug Manufacturing Inspections, lists the areas that should be covered when inspecting each of the six systems. This program provides additional guidance, by system, for areas of specific concern for sterile drug products. Attachment A is a list of questions intended to be an aid in conducting inspections and obtaining information needed to assess a firm’s operations. The answers do not have to be reported in the EIR unless they are relevant. The list of questions covers: moist heat sterilization; dry heat sterilization/depyrogenation; aseptic filling; lyophilization; isolators; environmental monitoring; and biological indicators. ### 3.5 QUALITY SYSTEM As noted in Compliance Program 7356.002, the inspection of the quality system is two-phased. The first phase is to evaluate whether the Quality Unit has fulfilled their responsibility regarding the review and approval of procedures and assured their suitability for use. The second phase is to assess the data collected by the firm to identify potential quality problems. For sterile manufacturing operations, this latter objective involves large amounts of data that link to the other inspectional systems. The comprehensive review of such data by the firm is an essential element in assuring that products are produced with a high degree of sterility assurance. It is therefore important to review the firm’s system for using the data to assess the state of control of their manufacturing operations and facility. The data summaries and trend reports maintained by the Quality Unit should be reviewed during every inspection. During a routine CGMP inspection, this review can help determine which option (Full or Abbreviated) to select. The inspection of the Quality System should include the areas listed in CP7356.002. For this program, the inspection should include a review of all data and reports that may indicate product contamination and sterility assurance issues. Records pertaining to quality consist of the following: 1. Periodic product evaluations, complaints, adverse events, investigations, Field Alert Reports, product retain evaluations, complaints, rejected lots, stability, and returned goods that indicate ===== PAGE 12 ===== PROGRAM 7356.002A PAGE 12 of 38 possible product contamination or risks to patients (for example, hazy or cloudy product, foreign matter/particulates in injectable products, cracked, and leaky containers). 2. Discrepancy and failure investigations, such as: o All initial positive sterility tests and endotoxin and media fill failures regardless of final disposition. o Unexpected results or trends. o All failures that occurred during validation or revalidation of sterilization / depyrogenation processes. o All investigations involving media fills / process simulations. o Environmental (microbial/viable and particle/non-viable counts) and personnel monitoring results that exceed alert or action levels. o Process deviations or equipment malfunctions that involve critical equipment, such as sterilizers and lyophilizers. o Out of Specification (OOS) results for assay, impurities, particulate matter, or reconstitution time, if applicable. o Product rejects (rejects determined during manufacturing and Quality Control test) 3. Trends reports/ summaries of quality indicators: o For aseptic processing, summary of all media fills performed since last inspection. o Environmental monitoring trend data (microbial and particle counts). o Personnel monitoring trend data. o Summary of water system test results. 4. Summary of change controls for critical utilities and equipment implemented since the last inspection, for example: o Sterilizers, lyophilizers, depyrogenation equipment o Aseptic processing line o Clean steam generator, process gas system o WFI and / or Purified Water system o Air handling systems o Automated building management system Every inspection of a sterile drug manufacturer should include a review of the type of information listed above and observation of the manufacturing operations occurring in the critical areas. The information can be used to select other system(s) to be covered during the inspection. In addition, the review of summary data and observation of operations can focus the inspection on potential problem areas and provides an overview of the effectiveness of the Quality System. The inspection of the Quality System may necessitate follow-up within another system. However, this coverage does not constitute or require complete coverage of these systems. ===== PAGE 13 ===== PROGRAM 7356.002A PAGE 13 of 38 ### 3.6 FACILITIES AND EQUIPMENT SYSTEM Compliance Program 7356.002 lists the general areas to cover when inspecting the Facilities and Equipment System. The areas are applicable to sterile drug products and should be covered if this system is selected. The principle objective of an effective sterile drug manufacturing operation from a facility and equipment standpoint is to provide suitable protection of product. The inspectional evaluation of this objective is again two-part: • Review and evaluate the firm’s rationale for, and adequacy of, the facility and equipment design (Reference: Section IV of FDA’s 2004 Aseptic Processing Guidance). • Evaluate the data that provide information relevant to the state of control of the facility and equipment. In addition to the review of design elements and data, investigators should look for visible deficiencies in the facility and equipment, such as cleanliness, equipment deterioration (e.g., warping, corrosion), inaccessible and/or difficult to clean surfaces, and changes to critical equipment or systems that have not been qualified which may impact product quality. Investigator should look for aberrant events due to facility deterioration, a pattern of recurring and uncorrected maintenance issues, and increase or changes in production output that exceed the capacity of the facility and equipment. A. FACILITIES Evaluate the design and layout of the facility (e.g., personnel/material flow, cleanroom design). Specifications for clean room areas (layout, air filtration, appropriate air classification, pressure differentials between rooms and areas, temperature, and humidity) should be appropriate, and based on the risk of product contamination with particulate matter and microorganisms. Review the certification and qualification of the clean room areas to verify the areas meet design criteria and specifications. Certification and qualification typically includes data in support of the following: air flow pattern studies, HEPA (High Efficiency Particulate Air) filter integrity testing, air velocity measurement, non- viable particle, and verification of appropriate pressure differentials, temperature and humidity setpoints. Evaluate the airflow pattern (smoke studies) conducted under dynamic conditions to verify the unidirectional airflow and air turbulence within the critical area where sterilized drug product, containers, and closures are exposed to environmental conditions. • Reference: Section IV of FDA’s 2004 Aseptic Processing Guidance. • Routine monitoring and maintenance to assure air handling systems continue to operate within established parameters (microbiological monitoring is discussed under the Laboratory Control System). o Afford special attention to facilities that are performing construction in the clean areas, or at the vicinity of cleanroom. Because microbes (e.g., fungal spores) can be liberated from the movement of walls and other construction activities, determine if the facility is returned to acceptable environmental control through proper measures (environmental monitoring, media fills) before production can resume. o Verify that environmental monitoring of non-viable particle is occurring during operations including sites where there is the most risk to exposed product, container and closures. ===== PAGE 14 ===== PROGRAM 7356.002A PAGE 14 of 38 o Check if pressure differentials, temperature, and humidity are continuously monitored during routine production. o Determine if continuous monitoring systems are alarmed to alert operators of excursions. o Check if excursions from acceptable ranges are investigated to determine impact on product and that needed corrective actions are taken. o Evaluate the program for periodic testing / recertification of the HEPA filters in critical areas to maintain appropriate air flow. The tests typically include integrity testing of the HEPA filters and air velocity checks. • Sanitization / disinfection of clean room areas, processing lines, and non autoclavable equipment, materials, and components should be reviewed. Focus on the areas where the sterile product is exposed up to and including sealing operations. These critical areas represent the highest risk to the product. The suitability, efficacy, and limitations of disinfecting agents and adequacy of procedures should be reviewed, including the data that establishes the expiry of the disinfection solution. (Reference: Section X.A.3 of FDA’s 2004 Aseptic Processing Guidance) • For multi-use facilities and non-dedicated equipment, evaluate the adequacy of the changeover procedures and cleaning to prevent cross-contamination between products. B. EQUIPMENT Equipment used in the manufacture of sterile drug products may include the following: • Production Equipment • Container/closure processing equipment (e.g. stopper washer, glassware depyrogenation equipment) • Support system/material system related equipment (e.g. WFI system and related equipment, process gas related equipment) Specific considerations include: (1) Production Equipment (a) Aseptic Processing Equipment. Determine that all equipment that comes in direct contact with product (e.g., filters, transfer lines, holding tanks, stopper bowls, filling line equipment) and sterile components (e.g., stoppers) are sterilized and protected from contamination prior to and during use. Equipment logs or other related information may provide insight into significant maintenance or other problems that may increase exposure of batches to contamination risk. (b) Stopper washer. Inspectional considerations include the qualification of the equipment, cycle validation and supporting data, equipment preventative maintenance (maintenance requirements and frequency), quality of water used for washing, and associated water sampling/qualification data. The appropriateness of the air supply used in any drying operations should also be verified. (c) Capping Equipment (vials). The vial cap provides the final closure element of a sealed vial. The capping machine folds and crimps the cap (aluminum) over the neck of the stoppered vial. The cap on the vial protects the stopper from external damage, while firmly holding the stopper ===== PAGE 15 ===== PROGRAM 7356.002A PAGE 15 of 38 in the fully seated, sealed position. Evaluate the established processing settings (crimp angles, pressures), and preventative maintenance schedules of the capping machine. Air supply quality to the capping units should also be evaluated. (d) Post fill Visual Inspection/Automated Inspection Equipment. The 100% inspection of the final filled and sealed product may occur via a manual, automated, or semi-automated inspection process. Manual and semi-automated inspection processes involve specified viewing fields and calibrated light sources. Semi-automated processes may use conveyor belts and rotational units that present the filled product to an operator for visual inspection. All conveyor and rotational speed set points should be verified against established parameters. Automated inspection systems may inspect for one or all types of defects in a given filled product. Defect categories with relevant action levels should be defined. The qualification of the equipment and the challenges performed to verify equipment functionality prior to routine use should be evaluated as well as the training program for operators performing manual visual inspections. (e) Sterilizers. The inspection should cover the Installation and Operation Qualification of equipment and the Performance Qualification of the process (IQ, OQ and PQ), and operation, calibration and preventative maintenance of representative types of equipment used to sterilize finished dosage forms, filling equipment, containers, closures, etc. Such equipment includes autoclaves, dry heat ovens, dry heat tunnels, steam-in-place (SIP) equipment and chemical sterilization systems (i.e., hydrogen peroxide, peracetic acid). Inspection of sterilizers should include physical examination of the equipment. Review the engineering specifications which may be described in the equipment’s DQ (Design Qualification). DQ is performed prior to the IQ (Installation Qualification) and OQ (Operational Qualification), and verify that the sterilizer is maintained, calibrated and drained properly and that it has appropriate measuring devices (temperature sensors, pressure gauges, etc.). Records of unplanned maintenance, as well as preventative maintenance, should be reviewed to assure all significant changes have been evaluated and qualified as appropriate. Equipment logs should also be reviewed. For example, repeat sterilization of loads because of cycle failures can indicate a serious problem with a sterilizer. Impact of re-sterilization to product quality should be evaluated. (Performance qualification is covered under the Production System). The equipment can be computer controlled or operated in a manual mode. For computer controlled system, programmable logic controller (PLC) or a more complex Supervisory Controlled and Data Acquisition Management System (SCADA), may require an assessment to determine if the computer control and/or monitoring system are Part 11 compliant. Reference: o PDA Technical Report No. 1 Revised 2007 Validation of Moist Heat Sterilization Processes: Cycle Design, Development, Qualification and Ongoing Control; o ISO 17665 Moist Heat Sterilization. (f) Lyophilizer. Because partially sealed vials are used in the lyophilization process, sterile product is exposed to the environment from the time of filling until the vials are fully stoppered in the lyophilization chamber at the end of the cycle. The inspection should verify that partially ===== PAGE 16 ===== PROGRAM 7356.002A PAGE 16 of 38 sealed vials are transported and loaded into the lyophilizers under Class 100 (ISO 5) protection. Investigators should observe the transport of vials and loading of lyophilizers. Other key equipment areas to cover include: validation of the sterilization of the lyophilization chamber between uses, current sterilization controls, leak testing of the chamber, integrity testing of air/gas filters, and calibration of temperature and pressure controllers. Reference: FDA’s Guide to Inspections of Lyophilization of Parenterals. (g) Isolators. Evaluate the design and control elements that maintain the separation or isolation of the product. Pressure differential, glove integrity, and protection of the transfer (i.e., entry, exit) ports are key elements for the isolators. The transfer of containers, closures and supplies (including environmental monitoring supplies) into an isolator should be carefully controlled. Another critical element for these systems is the effectiveness of the chamber decontamination program. Current methods (e.g., vaporized hydrogen peroxide, steam hydrogen peroxide, peracetic acid) used to decontaminate isolator barriers are capable of surface sterilization but lack the penetrating capabilities of steam sterilization. Investigators should be mindful of the limitations of these surface sterilants, including their inefficiency in penetrating obstructed or protected surfaces. Validation of the decontamination of the interior (surfaces) of an isolator should demonstrate a 6-log reduction of the biological indicator (BI). Quantitative measuring devices (e.g., near infrared) or chemical indicators (qualitative test) can be used to determine the worst case location for decontamination validation using BI. Factors to be considered in decontamination validation include the location of the BI and the type of surfaces where the BIs are inoculated. Utensils and equipment surfaces inside the isolator that have direct contact with sterile product and components should be sterilized to render them free of microorganisms. The sterilization validation should achieve a minimum of a 6-log reduction of the BI Reference: o Appendix 1 of FDA’s 2004 Aseptic Processing Guidance; o PDA Technical Report 51 (2010) Biological Indicators for Gas and Vapor Phase Decontamination Processes: Specifications, Manufacture, Control and Use provides general principles to be considered in decontamination by BI. (h) Restricted Access Barrier System (RABS). In general, a RABS is a fill-finish line in a rigid wall enclosure that provides full physical separation of the filling line from operators. It is important to note that the inside surfaces of the RABS are disinfected with a sporicidal agent2 , but this is not accomplished using the automated decontamination cycles employed for isolators. This requires firms to carefully supervise disinfection procedures and assure ongoing effectiveness of the disinfection program. Operators use glove ports, half suits or automation to access areas within the enclosure during filling. There are 2 types of RABS, “open” and “closed” RABS. The doors to a “closed” RABS are never opened during an operation. While an “open” RABS is designed to operate with doors closed at all times, on rare pre-defined circumstances 2 Robust disinfection of all non-product contact surfaces within the RABS should be performed with a suitable sporicidal agent before batch manufacture. Product contact equipment should be subject to sterilization. ===== PAGE 17 ===== PROGRAM 7356.002A PAGE 17 of 38 the doors of the enclosure can be opened to perform certain interventions. If doors are routinely opened during a filling operation, the system is not considered a RABS because it no longer restricts access to the critical areas. Typically, the cleanroom surrounding the RABS is controlled as a Class 10,000 (ISO 7) area and operators are fully gowned. Reference: Restricted Access Barrier Systems (RABS) for Aseptic Processing; ISPE; August 16 2005. When inspecting a RABS: o Determine that the gloves and gauntlets attached to the glove ports are sterile when installed. After installation, the gloves should be disinfected or changed at appropriate intervals to minimize the risk of contamination. o Verify there is a well defined written procedure that describes what is done when an open- door intervention is performed. All open-door interventions should be documented and described in batch records, and followed by disinfection. o RABS entry is often accompanied by an appropriate line clearance, which should be clearly documented in batch records. o Determine that all fluid pathways and product contact parts such as stopper bowl, feed and placement systems are sterilized prior to the filling of each batch. o Observe how sterile components and supplies are transferred to the RABS. Verify that the transfer system prevents exposure of sterile surfaces to less clean environments. o Verify that non-product contact surfaces within the RABS undergo thorough disinfection with a sporicidal agent before each batch. The effectiveness of the overall disinfection program should be validated and routinely evaluated by the environmental monitoring program. (i) Blow-fill-seal (BFS) Technology. BFS is an automated aseptic filling process in which containers are formed, filled and sealed in a continuous operation. BFS systems can reduce the risk of product contamination by reducing operator interventions. The systems are typically used for filling sterile ophthalmic and respiratory care products. See Appendix 2 of FDA’s 2004 Aseptic Processing Guidance for information about BFS systems. It should be noted that the inner surfaces of the containers can be exposed to the surrounding environment during the formation and molding steps prior to filling. The sterile product can also be exposed to the environment during the filling and sealing steps of the BFS process. Therefore, the air quality should meet the microbiological level established for Class 100 (ISO 5) should be supplied to where the sterile product or its containers are exposed during the BFS process. Some of the more advanced BFS equipments that provide enhanced protection for the sterile product operation can be located in a Class 100,000 (ISO 8) area. Otherwise, a Class 10,000 (ISO 7) area is appropriate. Research has demonstrated a direct relationship between the number of contaminated units and the level of microbial contamination in the air surrounding the machine (see Reference #20). Typically, the product supply line and sterilizing product filters are steam sterilized-in-place (SIP). When inspecting BFS: ===== PAGE 18 ===== PROGRAM 7356.002A PAGE 18 of 38 o Verify that HEPA-filtered or sterile air is used during steps where sterile product or materials are exposed (e.g., parison formation, container molding, and filling steps). o Evaluate the monitoring and preventative maintenance programs to determine the integrity of the utilities (cooling water, heating, etc.) associated with the BFS machine is routinely checked. Leaks in the molds or utility connections at the molds can contaminate the sterile product or containers. o Review the SIP system used to sterilize the product line. Determine the sterilization cycle has been validated and the condensate properly drains from the line. The line should also be protected between sterilization and use. o Verify that personnel who enter the classified environment surrounding the BFS machine are properly gowned and trained. o If possible, observe equipment setup and any difficulties that can lead to contamination risks. Other control procedures (media fills, environmental monitoring, disinfection of surfaces, etc.) are the same as discussed for conventional aseptic processing line. (j) Reactor, Centrifuge, Dryer, Mill. This type of equipment can be used to aseptically manufacture sterile bulk Active Pharmaceutical Ingredients (APIs). The equipment and all transfer piping must be sterilized prior to processing. This is typically done with sterilize-in- place (SIP) systems which use clean steam or a chemical sterilant. Review the validation, cycle controls and the routine monitoring of the SIP system. The equipment and all transfer piping must remain integral (no fluid or air leaks) and sterile throughout the entire manufacturing process. Determine how the firm verifies the integrity of the equipment train throughout the process. If a piece of equipment is opened in the process (e.g. adding seed crystals), verify the area surrounding the open operation is robustly protected from contamination risks with a Class 100 (ISO 5) air system as well as implementing a carefully designed aseptic operation. Reference: FDA’s Guide to Inspections of Sterile Drug Substance Manufacturers. (2) Container/Closure Processing Equipment Depyrogenation equipment may include a dry heat oven and/or depyrogenation tunnel. Depyrogenation of stoppers can also be accomplished by dilution via a washing process. The final rinse of the washing process uses Water for Injection (WFI). For more information, see FDA’s Aseptic Processing Guidance, Section VI.B, Containers/Closures. (3) Support Utilities (a) Water System. Specifically, review WFI generation equipment and distribution loop(s), including tanks, water lines, isometric diagrams, vent filters, and preventive maintenance schedules (See also Materials System). Monitoring equipment associated with the Water System should also be evaluated. (b)HVAC. Refer to Section IV of FDA’s 2004 Aseptic Processing Guidance on qualification and maintenance of the HVAC system. ===== PAGE 19 ===== PROGRAM 7356.002A PAGE 19 of 38 (c) Process Gases. Gases that are in contact with the drug product or components in drug manufacturing operations are referred to as process gases. Gases used in aseptic operations, or downstream of sterilization, must be filtered through a sterilizing grade filter to maintain asepsis. The integrity testing of these filters (typically hydrophobic) should be evaluated. The system used in the generation of the process gas(es) should also be evaluated including preventive maintenance (PM) schedules, monitoring (including temperature, pressure, and humidity), and sampling. See also under Materials System. ### 3.7 MATERIALS SYSTEM Compliance Program 7356.002 lists the areas to cover when inspecting the Materials System. The areas are applicable to sterile drug products and should be covered if this system is selected. In sterile operations, the quality attributes of each of the materials (ingredients, WFI, containers, closures) have a bearing on the critical attributes of the finished product. Review the firm’s procedures for receipt, handling, sampling, testing, approval and storage of manufacturing materials to verify their fitness for use. Emphasis should be placed on incoming materials that are represented to be sterile and / or pyrogen free. Areas of special concern for sterile drug products include: (1) Water Systems. Water for Injection (WFI) is an ingredient in many sterile drugs, including injectable products and sterile ophthalmic products. It is also used in depyrogenation (or endotoxin removal) of equipment and stoppers and in cleaning operations. The quality of the water, and its endotoxin levels and controls, used in the upstream process should also be evaluated in order to ensure the removal of bacterial endotoxin to the appropriate level downstream. Purified water can be used for some sterile non-injectable solutions. • Observe and understand elements of the generation and distribution systems. • Evaluate the water system “As Built” diagrams” and inspect for leaks, pipe slopes (via the isometric diagrams and verification of the degree of the slopes), so called “dead legs”, and non-sanitary fittings in the distribution system. • Evaluate how microbial alert and action levels are established. • Evaluate sampling sites, procedures, frequencies and tests performed. • Review procedures for preventative maintenance and calibration of critical instruments, including scheduling and equipment update procedures. • Review raw data to verify that all of the above is completed per established procedure. • Review and observe routine monitoring (in-line TOC and conductivity) of water system. • Review trend data for chemistry, microbiological and endotoxin tests. • Review investigation of results that are at or over alert and action levels. Reference: FDA’s Guide to Inspections of High Purity Water Systems. (2) Process Gas. Process gas and related equipment controls may be covered in conjunction with the Facilities and Equipment System. Specific considerations include controls over final filtration of the ===== PAGE 20 ===== PROGRAM 7356.002A PAGE 20 of 38 processed gas and filter integrity testing. Gas used as a component in a finished product may include the Nitrogen gas overlay for Oxygen sensitive products. (3) Pre-washed / Ready to Sterilize Closures. The CGMP regulation (21 CFR 211.94(c)) states that, where indicated, containers and closures must be processed to remove pyrogenic substances. Many manufacturers of small volume parenterals purchase stoppers that are ready-to-sterilize, (i.e., they are pyrogen-free). No washing or depyrogenation is done by the dosage form manufacturers but these firms are still responsible for assuring the stoppers are of acceptable quality for use in manufacturing. The pyrogen requirements should be included in specifications for the stoppers and, if the manufacturer does not conduct testing of each incoming lots for pyrogen/endotoxin, they should establish the reliability of the supplier’s test results by qualification of the vendor, followed by periodic testing. (4) Microbiological and Endotoxin Testing of Component, Container and Closure. 21 CFR 211.84(d) specifies that each lot of component, container or closure that is liable to microbial contamination which is objectionable in view of its intended use shall be subjected to microbiological tests before use. Evaluate the firm’s system for determining if microbiological or endotoxin testing is required and the rationale for setting acceptance criteria. Review test data to verify that the materials meet test criteria and, if not, verify that investigations were conducted to determine the cause and corrective actions were implemented. (5) Verification of Container and Closures. The physical and chemical characteristics of containers and closures can be critical to the sterility and stability of the finished product. Many containers and closures look alike (color and dimensions), but are made of different materials or have a different surface treatment such as silicone on stoppers and ammonium sulfate on Type I glass. Evaluate the firm’s procedures for assuring containers and closure consistently meet appropriate specifications. Determine what tests and examinations are done to verify the containers and closures are made of the correct materials with the correct dimensions (critical to ensuring continuing container-closure integrity) and are free of critical defects. (6) Container / Closure Integrity. The integrity of the container / closure system is critical to assuring that all units of drug products remain sterile through shipment, storage and use. Leaking containers or closures lead to product contamination. Reference: FDA’s 1994 Guidance for Industry for the Submission of Sterilization Process Validation in Applications for Human and Veterinary Drug Products. Evaluate the tests and studies performed to demonstrate the integrity of container / closure systems for all sterile drugs, including: • Verify that all incoming container-closure components meet specifications, including all appropriate dimensions. • Determine studies adequately simulate the stress conditions of the sterilization process, handling and storage. • Verify that the units tested in validation are appropriate (e.g., for terminally sterilized drug product, the units selected should be exposed to the maximum sterilization cycles using the production process). ===== PAGE 21 ===== PROGRAM 7356.002A PAGE 21 of 38 • Sensitivity of the test is specified. • Container-closure integrity is demonstrated during validation and as part of the stability program (in lieu of sterility testing), over the shelf life of the product. ===== PAGE 22 ===== PROGRAM 7356.002A PAGE 22 of 38 ### 3.8 PRODUCTION SYSTEM Compliance Program 7356.002 lists areas to cover when inspecting the Production System. The listed areas are applicable to sterile drug products and should be covered during inspections. Production practices and conditions can have a direct and significant adverse impact on drug sterility assurance. The Production System, as well as the Quality System, should be included in all Full Inspections. Coverage of critical elements, which are typically defined by the firm of the Production System, should be part of all inspections (full and abbreviated) of aseptically processed sterile drug manufacturers. The risk of contamination posed by an operation depends greatly on the design of the overall manufacturing operation. Observation of manufacturing is a critical part of evaluating the adequacy of an aseptic processing operation. The following should be carefully observed. • adequacy of aseptic technique [See section V of FDA aseptic processing guidance] • personnel behavior and practices in the cleanroom [See section V of FDA aseptic processing guidance] • movement of people and materials before and during the aseptic operation • robustness of production process design (e.g., process performance, validation, impact of equipment configuration on ergonomics of aseptic manipulations) [See section IV of FDA aseptic processing guidance] • disinfection practices [See section X.A.3 of FDA aseptic processing guidance] More specifically, the inspection must include real time observation of the higher risk operations including but not limited to (these are examples and not an all inclusive list): • Set-up of filling lines, especially difficult to assemble lines (e.g. powder filling lines), and lines that require multiple aseptic assemblies or do not employ SIP of the product pathway. • Cleaning and disinfection of the line and room to ensure all difficult to access surfaces are consistently and properly cleaned and disinfected. • Protection of critical contact surfaces to ensure their sterility throughout operations and post sterilizations. • Aseptic technique and cleanroom behavior during operations, including handling of equipment jams and stoppages. • Personnel flow in relation to microbial control of the environment. • Material flow (e.g., whether materials are moved from a lesser controlled area to a cleaner area without disinfection), including number of staff and their activities in the aseptic filling room. • Filling operations, especially personnel gowning technique, gown integrity, strict adherence to SOPs), the nature and frequency of interventions (interventions are also performed during the media fill simulations), and overall condition of the critical filling area. • Atypical interventions associated with unplanned events (e.g., operator attempts to change the filling pump during operations). ===== PAGE 23 ===== PROGRAM 7356.002A PAGE 23 of 38 • Extra manipulations during filling operations for assembly of sterile filtration apparatus that is not SIP sterilized. • Handling (transfer, storage, loading) of partially stoppered vials in lyophilization processes. Note that for lyophilized products, vials of sterile products are stoppered but not fully sealed until the lyophilization process is completed. The sterile product is exposed to the environment during filling, half-stoppering, transport, loading of the lyophilizer, and the lyophilization cycle. Complete seating of stoppers typically occurs in the chamber after the cycle is completed. All of these manipulations must be performed under Class 100 conditions. • Preparation of equipment for sterilization (cleaning, the type of wrapping to ensure protection while still allowing for penetration as part of the validated sterilization cycle with defined loading patterns). • Environmental monitoring (while the monitoring program is considered a Laboratory System, inspection should include observation of the actual monitoring operations and rationale for sample site locations). • Proper placement and sealing of stoppers on vials as applicable, and the capping (aluminum crimp) is performed in a protected area under unidirectional flow. • Production of sterile suspensions and sterile bulk powders (e.g., antibiotics) where sterile filtration of the final bulk is not feasible. These are typically formulated and manufactured under aseptic conditions. This requires the sterilization of large pieces of production equipment (e.g., tanks, reactors, dryers and associated lines) and assurance that these pieces of equipment retain their integrity and remain sterile. Critical operations that should be covered during an inspection of the Production System include: (1) Media fills or process simulations. Media fills are used to validate aseptic processing operations, including those employing newer technologies, such as isolators, BFS or RABS systems. Media fills representing manually intensive aseptic operations should equal or approach the size and duration of a commercial production lot. In contrast, a process conducted in an isolator is designed to have a lower risk of microbial contamination because of the lack of direct human intervention and can be simulated with a lower number of units as a proportion of the overall operation. All media fills should closely simulate manufacturing operations, incorporating, as appropriate, worst-case activities and conditions as well as operator interventions. FDA’s current expectations for media fills are discussed in Section IX.A of the 2004 Aseptic Processing Guidance. • Verify Media Fills represent actual manufacturing operations by comparing observed operations to those documented in Media Fill batch records. • Determine if media fills are conducted semi-annually for each processing line. The activities and interventions representative of each shift should be included in the semi-annual media fill program. This may require more than one media fill per line every 6 months, if aseptic processing is performed during more than one shift. With the exception of isolator operations, at least one semi-annual media fill is performed per line per shift. Determine if the aseptic filling of all types of containers are supported by the media fills performed. If a matrix approach is used, evaluate the firm’s justification for selecting the worst case container / closure configurations for each line. • Determine accountability of all filled units (units filled vs. units incubated). ===== PAGE 24 ===== PROGRAM 7356.002A PAGE 24 of 38 • Verify that all units that were discarded during and after filling have a reasonable and assignable cause for rejection (e.g., rubber stopper missing, aluminum cap missing). • Determine that cracked and leaking units found after incubation are investigated, counted and all rejected units properly justified (e.g., is there an assignable cause that is reasonable for the rejection?). • Determine how and who examines units after incubation. If the examination is not performed by a microbiologist, determine if it is overseen by the quality unit and if the operators doing the exam are properly trained by a microbiologist. Reference: • FDA’s 2004 Aseptic Processing Guidance, Section IX A. • PDA Technical Report No. 28, revised 2006, Process Simulation Testing for Sterile Bulk Pharmaceutical Chemicals. • PDA Technical Report No. 22, revised 2011, Process Simulation for Aseptically Filled Products. (2) Sterile filtration (aseptic processing). • Verify filters used in production are identical to those used in validation studies (i.e., those submitted in drug applications) • Verify that actual operating parameters and allowable extremes are covered in the validation studies. • Determine that validation of filter sterilization has been performed for all products. Pay special attention to legacy products. These include older products and those for which applications have not been submitted. • Observe filter integrity testing to verify procedures are followed. • Review investigations of any integrity test failures. Reference: • FDA’s 2004 Aseptic Processing Guidance, Section IX.B; and • PDA Technical Report #26, 2008, Sterilizing Filtration of Liquids. (3) Sterilization and depyrogenation of containers, closures and processing equipment. • Review the validation or revalidation of sterilization and depyrogenation processes used for containers, closures and, in the case of aseptic processing, equipment that comes in contact with the sterile product or sterile components. • Check if firm verifies that validated parameters (loading patterns, cycle parameters) are met for each load. • Rubber stoppers that are not purchased pre-sterilized or pre-siliconized may require depyrogenation and siliconization prior to use. As previously noted, depyrogenation may be achieved via a washing dilution process with the use of repeated WFI washing steps. The validation should demonstrate a successful 3-log reduction of bacterial endotoxin. When the firm performs its own siliconization of stoppers, silicon level after wash should be validated to meet the predetermined acceptance criteria. ===== PAGE 25 ===== PROGRAM 7356.002A PAGE 25 of 38 • Stoppers are sterilized by steam sterilization. Verify that the clean steam used to provide the sterilization is acceptable and has been assayed for endotoxin. • Review the practices and procedures to determine if a firm needs to revalidate the sterilization and depyrogenation process. • Review change control procedures. • Determine if reprocessing is performed. • Evaluate bioburden level: Evaluate the firm’s understanding of process bioburden (e.g., from incoming components/container/closure) and determine if the firm has adequately validated hold time for critical steps. It is important to note that increased bioburden can lead to the degradation of the drug product as well as contributing impurities (including endotoxin) to the drug product. Sampling points (location in process flow) and methods should be evaluated based on product quality risks. (4) Lyophilization. • Review the validation of lyophilization cycles established for selected products. • Verify the firm confirms all critical cycle parameters are met for each lot. • Determine environmental monitoring is routinely performed in the areas of loading and unloading of the product from the lyophilizer. In addition, ensure personnel monitoring is conducted on those operators who perform the loading and unloading operations. • Observe the transport of the partially stoppered vials and the loading of the lyophilization chambers to verify it is done under proper environmental conditions (Class 100) and to verify that proper aseptic techniques are used. Reference: FDA’s Guide to Inspections of Lyophilization of Parenterals. (5) Sealing of vials. • A vial is not sealed until the aluminum overseal is placed over the rubber stopper and crimped in place. • If stoppered vials exit the aseptic processing zone prior to capping, verify proper safeguards are in place, such as HEPA filtered air protection and qualified in-line detectors that reject vials with improperly seated stoppers. (6) Terminal sterilization. • Determine what type of sterilization cycles are used (bioburden based or overkill). • Review validation / revalidation / or periodic evaluation of terminal sterilization cycles for representative types of products. • For selected products, verify that the parameters and loading patterns used in production are the same as those used in validation studies. • Determine the minimum acceptable cycle allowed in the SOP (as opposed to the nominal or routine cycle) and compare that to the validated cycle (using BI) to verify it has been properly qualified. • Determine how sterilization cycles are documented, monitored and reviewed. ===== PAGE 26 ===== PROGRAM 7356.002A PAGE 26 of 38 • Review deviations or atypical data from sterilization operations that indicate inconsistencies in process performance. (7) Parametric release of terminally sterilized drug product. This is defined as a sterility assurance release based on demonstrated control of the sterilization process. It enables a firm to use defined critical process control data, in lieu of the sterility test to fulfill the intent of 21 CFR 211.167(a). It is allowed only for products that are terminally sterilized by heat and it must be identified in the appropriate regulatory filing as the release method. Parametrically released product must have an approved application. • If encountered during an inspection, verify the parametric release method has been submitted and approved in the appropriate drug application. If the drug is not the subject of an approved application, collect pertinent information and validation data for evaluation by the Center. • Verify that the conditions described in FDA’s Compliance Policy Guide Section 490.200, Parametric Release – Drug Products Terminally Sterilized by Heat, are met. (8) 100% inspection of injectable products including: cracks, visible particles and other significant defects. • Verify the firm has written procedures that define the defects to be removed from the lot and actions to take if the number of critical defects exceeds a pre-determined level. • Significant defect categories should be identified. Results of inspection of each batch should be compared to established action levels. • Evaluate the appropriateness of and the rationale or justification for pre-determined action levels. • Evaluate the firm’s investigation into the cause of rejects, including units rejected for cracks and visible particulates (e.g., foreign matter). • Observe the inspection process. • Challenge visual/manual inspection rates through observation. • Evaluate the adequacy of written procedures for visual inspection. • Evaluate personnel qualification and requalification and equipment qualifications according to established procedures. Evaluate personnel qualification including the use of reference samples for qualification. o If a manual system is used, determine if employees are trained and qualified to verify they can recognize and remove defects under actual or simulated production conditions. o If an automated or semi-automated system is used, determine the equipment is qualified and the software program or equipment settings have been validated for all types of products being inspected (e.g., clear vials, amber vials, colored solution, suspensions). If the equipment is an automatically controlled computer based system, an assessment of the system and validation is warranted. • Evaluate the firm’s program for sampling and examination of inspected vials and evaluate the effectiveness of inspection and action taken if the reject level is reached. ===== PAGE 27 ===== PROGRAM 7356.002A PAGE 27 of 38 • Evaluate the firm’s assessment of units rejected during filling operations (any separate inspection prior to the 100% inspection stage), established alert/action limits, and investigations where appropriate. (9) Personnel (gowning, training, aseptic techniques). The type of gowns and personal protective equipment (PPE) worn by employees should be appropriate for the areas in which they work. There should be detailed written procedures that describe the gowning requirements for each processing area. Evaluate the following: • For aseptic processing, determine the gowns (which typically include face masks, hoods, protective goggles, gloves, and boots) are sterilized and made of non-particle shedding material. Ensure that the gowns cover all skin, hair and facial hair. • Review how the incoming sterile gowns/garb are accepted or rejected for use. • Evaluate the firm’s program for training, testing and qualifying and re-qualifying employees who work in the controlled areas, especially those who set-up and operate aseptic processing lines. • Evaluate the aseptic techniques of employees by observing aseptic processing operations. • For selected employees, verify the training, testing, qualifying, and re-qualifying were done as specified in procedures. • Verify the training is done on a continuing basis. Reference: FDA’s 2004 Aseptic Processing Guidance, Section V. (10) Batch records. • Review of environmental and personnel monitoring data, as well as other data relating to acceptability of support systems (e.g., HEPA / HVAC, WFI, steam generator) and manufacturing equipment. This review is considered essential to batch release decisions. The batch record should include documentation that assures this type of holistic review is done before the release of a lot for distribution. • For aseptic processing, verify interventions into critical areas (Class 100/ ISO 5) are documented so they can be reviewed and evaluated by the Quality Unit. • Review batch records to verify they include complete information for all sterilization processes. Reference: FDA Aseptic Processing Guidance, Section XII. (11) Environmental and personnel monitoring. • See section below under “Laboratory Control System”. ===== PAGE 28 ===== PROGRAM 7356.002A PAGE 28 of 38 ### 3.9 PACKAGING AND LABELING SYSTEM Compliance Program 7356.002 lists the areas to cover when inspecting the Packaging and Labeling Control System. All of the areas that are applicable to sterile drug products and should be covered if this system is selected for coverage. Areas of special concern for sterile products include: • Determine that packaging and labeling operations do not introduce risk to product integrity (for example, damage to the container or closure that could affect the integrity of the unit). • Determine that the container, closure and packaging systems provide adequate protection against foreseeable external factors in storage, shipment, and use that can cause contamination or deterioration (e.g. cracked vials during shipment if not properly protected; pinhole leaks in bags, frozen drug products, tears or holes in overwraps of sterile bulk antibiotics and large volume parenterals; and unseating of stoppers in aluminum cans containing sterile bulk APIs due to pressure changes during shipment by air). • It is not unusual for filled containers of sterile products to be stored unlabeled for a period of time. The firm must have adequate controls to assure proper identification of the unlabeled product at all times. • Tracking of refrigerated or temperature controlled units for room temperature exposure times (e.g. warm up of refrigerated units prior to label application). • Tracking and investigation (as specified and appropriate) of rejected units culled during packaging and labeling operations. ### 3.10 LABORATORY CONTROL SYSTEM Compliance Program 7356.002 lists general areas to cover when inspecting laboratories. Inspections of sterile drug manufacturers should also cover microbiology laboratories. Quality control tests (sterility and Limulus Amebocyte Lysate or LAL test) and the collection of environmental and personnel monitoring samples should be observed to verify that acceptable techniques are used and written procedures are followed. The inspection of microbiology laboratory should evaluate the following: • Sterility testing, including the collection of samples that are representative of the entire lot and processing conditions; adequate control and monitoring of the testing environment; validation of the method for specific products; growth promotion testing of the media; and incubation times and temperature. It is important to note that increasing the number of samples or the number of tests does not greatly increase the probability of detecting contamination if it is present at a very low level in a lot. Reference: FDA’s Guide to Inspections of Microbiology Pharmaceutical Quality Control Laboratories and FDA’s 2004 Aseptic Processing Guidance, Section XI. • LAL testing, including product specific validation; collection of representative samples of raw materials, components/containers, in-process, and finished product, where appropriate; and adequate laboratory facilities for conducting the tests. Verify the rationale of sample size of endotoxin test relative to the production batch. Reference: Bacterial endotoxins – Test methodologies, routine monitoring, and alternatives to batch testing. ANSI/AAMI ST 72:2002/ (R) 2010, Association for the Advancement of Medical Instrumentation. • Environmental monitoring, which includes: a well defined written program that covers all production shifts and includes air, floors, walls, equipment surfaces, and, in aseptic process ===== PAGE 29 ===== PROGRAM 7356.002A PAGE 29 of 38 operations, critical surfaces that come in contact with sterile product, containers and closures; establishment of appropriate alert and action levels, use of sampling (contact plates, swabs, active air samplers) and testing methods (media, plate exposure times, incubation times and temperatures) that are designed to detect environmental isolates. Evaluation of the validity of the sampling locations and sampling methods. Reference: FDA 2004 Aseptic Processing Guidance, Section X. Note: environmental monitoring is performed during the processing of all types of sterile drug products, including an appropriate program for terminally sterilized products. • Personnel monitoring which includes: a routine program for daily/shift monitoring of operators gloves and an appropriate schedule for monitoring gowns; establishment of limits that are based on the contamination risk to the product; and investigations of results that exceed the established levels or demonstrate an adverse trend. Personnel monitoring is important in all sterile product operations, but it is especially critical in aseptic processing, and inspectional emphasis should be risk based, focusing on those operations that require employees to enter the critical areas of the processing line. Reference: FDA’s 2004 Aseptic Processing Guidance, Section V.C. • Efficacy of disinfectants, including assessment of the suitability, efficacy and limitations of the disinfecting agents used in the controlled area, production equipment and laboratories. The firm’s assessment typically includes laboratory studies that test the effectiveness of agents on different surface materials. Material coupons are usually used with surfaces types as found in production. The studies should be done with the same disinfecting agents, contact times (which should be clearly defined in written procedures). It is also important to understand that disinfectants have limitations and most are not effective against every type of microorganism. For this reason, firms should normally use more than one type of disinfectant. Reference: FDA’s 2004 Aseptic Processing Guidance, Section X.A.3. • Identification of microorganisms, including procedures that require identification of organisms found in positive sterility tests, media fills, and environmental monitoring (environmental and personnel) samples as specified by the firm. The program should assure routine identification of microorganisms found in samples are taken in critical areas, surrounding areas and from personnel in the production area. Review the procedures, equipment and controls used in identification activities of the contaminants. • Microbiological media, including the preparation, sterilization and growth promotion testing of the media used in performing tests (sterility tests, raw material testing, pre-filtration bioburden, environmental monitoring, media fills, etc.). Where appropriate, inactivating agents for disinfectants or product residuals should be added to allow detection of contaminants. • BIs and biological cultures used in sterilization validation studies should be used and stored under appropriate conditions. Typically, the conditions are described in the literature received with the BI, if supplied by a vendor. The microbial population should be confirmed by testing each lot. Spore counts should be verified prior to use in validation studies. The D-value should be determined for each lot of a BI if it is used in a way not described by the vendor. If used specifically as directed, the D-value supplied by the vendor can be accepted if the reliability of the Certificate of Analysis has been established, but D-value of incoming batches should be periodically verified. Reference: 2004 FDA Aseptic Guidance. ===== PAGE 30 ===== PROGRAM 7356.002A PAGE 30 of 38 • Microorganisms (e.g., ATCC) are used for growth promotion tests of media. Organisms isolated from environmental monitoring samples can also be used to perform growth promotion test. • Monitoring, calibration and maintenance programs for microbiology laboratory equipment, such as incubators. • Training of microbiologists and evaluation of microbiologists or technicians that perform sterility, LAL and environmental monitoring tests. • Documented investigations into out-of-specification results. Evaluate positive sterility tests and media fill and LAL failures investigations. Also review environmental / personnel monitoring results at alert and action levels to identify and determine the firm’s response to the significant incidents or trends. Because of the limited sensitivity of the sterility tests to detect batch contamination, any positive is a serious issue and should be thoroughly investigated by the firm with quality unit oversight and approval. The investigation and followed should be reviewed during inspections to assess the decision making process. An initial positive can be found invalid only if there is clear documented evidence that the microbial growth was unequivocally a laboratory error. Reference: Section XI.C of FDA’s 2004 Aseptic Processing Guidance. 21 CFR 211.180(e) requires that records be maintained in such a manner that the data can be used to evaluate adherence to quality standards. The evaluation of data generated by the microbiology lab plays an integral role in establishing the sterility assurance of the finished product. The inspection should determine if the firm generates and reviews testing data and product quality related data (e.g., trend reports) to make timely, informed and science-based decisions to assure an ongoing state of control. ### 3.11 SAMPLING Samples of sterile drug products should be collected to document suspected contamination, adulteration or misbranding encountered during an inspection. The samples can be physical or documentary. In the event of a for-cause assignment where in-process samples are being requested, collect the samples aseptically at points where such contamination might occur. These samples should be collected by the firm under the observation of the investigator. Great care shall be taken to prevent the possibility of contamination and/or compromising the integrity of the sample for all physical samples of raw materials, in-process samples or finished drug products. Consult the district management and/or Center as well as the servicing laboratory for guidance on sample size and sampling techniques. A production lot with an initial sterility failure result that was invalidated by the firm may be considered a good candidate for sampling. Physical sample analysis is not necessary to document CGMP deficiencies. Documentary samples may be submitted when the documentation illustrates the deficiencies and to obtain evidence of interstate shipment. Please be aware to collect the appropriate number of sample units in order to accommodate the 702(b) section of the Act. For finished products requiring sterility testing, collect 48 units of product. For finished products requiring endotoxin testing, collect 20 units of product. For additional sampling guidance, refer to Investigations Operations Manual (IOM) Chapter 4. ===== PAGE 31 ===== PROGRAM 7356.002A PAGE 31 of 38 [end Part III] ===== PAGE 32 ===== PROGRAM 7356.002A PAGE 32 of 38 PART IV - ANALYTICAL In general, samples will be submitted to your District's designated servicing laboratory, except as requested in a special assignment or your supervisor. 4.1 . ANALYZING LABORATORIES For Sterility and Bacterial Endotoxin testing: Region Examining Laboratory NER NRL SER SRL CER NRL PAR SAN-DO SWR DEN-DO For particulate matter in injectables analysis, contact the ORA/Office of Regulatory Science/Medical Products and Tobacco Staff to determine the most appropriate laboratory for this test. ### 4.2 ANALYSIS Sterility testing methods should be based on current editions of USP <71> Sterility Tests and the Sterility Analytical Manual (SAM). The SAM provides supplemental information to the USP. The SAM has the goal of standardizing the performance of testing for pharmaceutical microbiology in FDA laboratories. Bacterial endotoxin testing methods should be based on current editions of USP <85> Bacterial Endotoxin Test and the Sterility Analytical Manual (SAM). Particulate matter testing methods should be based on current editions of USP <78>. Other microbiological examinations should be based on appropriate sections of USP and the SAM. [end Part IV] ===== PAGE 33 ===== PROGRAM 7356.002A PAGE 33 of 38 PART V - REGULATORY/ADMINISTRATIVE STRATEGY A recommendation for regulatory action should be submitted by the District Office when a judgment is made that the firm is not operating in a state of control and management of the firm is unwilling or unable to make adequate corrective actions in an appropriate time frame. The therapeutic use of the drug product and the potential adverse effect of the CGMP deviations on the finished product must be considered in determining the appropriate action needed. When deciding the type of action to recommend, the initial decision should be based on the seriousness of the problem and the most effective way to protect the consumer (i.e., when non-sterile parenterals are found, injunction/seizure, recall would be the action(s) of choice). Instructions in the Regulatory Procedures Manual (RPM) should be followed. If the nature of the CGMP deviations is determined to pose minimal risks when considered in relation to the intended use of the drug, the primary action should normally be voluntary corrections by the firm. The District should require that all commitments for achieving voluntary compliance by firm management be submitted in writing and contain a time schedule for completion. The District should determine if the schedule is a reasonable time frame and should monitor the progress. When voluntary action is not accomplished or when the deviations observed pose a serious risk to the consumer, regulatory and / or administrative action should be recommended. NOTE: Regulatory action is independent of the collection of a violative physical sample. The lack of a violative physical sample is not a barrier to pursuing regulatory and/or administrative action providing the CGMP deficiencies have been well documented. Physical samples found to be in compliance likewise are not a barrier to pursuing action under CGMP charges. The following list of deficiencies represents examples of practices that CDER believes could warrant regulatory and/or administrative action (please note the following is not intended to be an inclusive list): 1. Contamination with filth, objectionable microorganisms, toxic chemicals or other drug chemicals; or a reasonable potential for product contamination, with demonstrated avenues of contamination such as poor aseptic methods, contact with unclean equipment, or airborne contamination. 2. Failure to assure that each batch conforms to label claims or established specifications, such as NDA, ANDA, USP monographs, and the firm’s finished product specifications. 3. Distribution of product which does not conform to established specifications. 4. Lack of adequate validation of critical steps in sterilization processes, including sterilization by filtration; sterilization cycles used for drug products; and, for aseptically processed products, sterilization processes used to sterilize components (formulation and/or its ingredients, as well as containers and closures), or to sterilize equipment surfaces that contact sterile product or any elements of the product. 5. Lack of adequate validation of aseptic processing operations (media fills). ===== PAGE 34 ===== PROGRAM 7356.002A PAGE 34 of 38 6. Failure to appropriately conduct and document investigations of discrepancies and failures of drug products or any of their components to meet specifications, especially inadequate investigations of sterility test failures, media fill failures and repeated or significant environmental or personnel monitoring results that meet or exceed action levels. 7. Facilities and equipment which do not provide adequate protection for aseptically processed product while the sterile product or sterile components are exposed to the environment. This includes both lack of robustness due to poor design, as well as failure to maintain equipment as sterile (e.g., by providing proper barriers as well as assuring adequate sterilization frequency). 8. Failure to assure a robust cleanroom disinfection program. This may include the failure to assure sufficiently detailed cleaning procedures to assure repeatability in cleaning, or failure to demonstrate the suitability and efficacy of the disinfecting agents used for the critical controlled areas and production equipment. 9. Failure of a WFI system to deliver water that consistently meets chemical, microbiological and endotoxin specifications. 10. For aseptic processing, poor employee practices that increase the risk of product contamination. 11. Failure to provide adequate training to employees who work in critical operations, such as operators on aseptic processing lines, operators responsible for initiating and checking sterilization cycles and those who perform the 100% inspection of filled injectable products. 12. Failure to perform adequate 100% inspections of injectable products for particulate matter and other defects. 13. Failure of batch records to include complete information related to the production and control of each batch, including documentation that assures environmental and personnel monitoring data and data related to the support systems, and assure quality unit review of these records prior to approval of a lot for distribution and release. For aseptically processed product, batch documentation includes records of purposeful operator interventions into critical (Class 100 / ISO 5) areas of the line. Operator intervention should be minimized as much as possible to preclude and control contamination. 14. Use of test methodology (sterility test, endotoxin test) that is not adequate or validated. 15. Lack of an adequate environmental monitoring program, that is, one that does not include dynamic monitoring during all production shifts or has not established appropriate alert and action levels and, in the case of aseptic processing, does not include representative critical surfaces that come in contact with sterile product, containers and closures. 16. Lack of an adequate personnel monitoring program for aseptic processing operations. For example, the program does not include daily monitoring of operators’ gloves and periodic monitoring of gowns; has not established appropriate limits or does not require investigations and corrective actions when limits are exceeded. [end Part V] ===== PAGE 35 ===== PROGRAM 7356.002A PAGE 35 of 38 PART VI - REFERENCES, ATTACHMENTS, AND PROGRAM CONTACTS ### 6.1 REFERENCES All of the references listed below, with the exception of number 17 through 26, are available on FDA’s internet website. 1. Code of Federal Regulations, Title 210 and 211 as revised, including the preamble. 2. Guidance for Industry Sterile Drug Products Produced by Aseptic Processing – Current Good Manufacturing Practice; FDA; September 2004. 3. Guidance for Industry for the Submission Documentation for Sterilization Process Validation in Applications for Human and Veterinary Drug Products; FDA; November 1994. 4. Guidance for Industry Process Validation: General Principles and Practices of Process; FDA; January 2011. 5. Guide to Inspections of Lyophilization of Parenterals; FDA; July 1993. 6. Guide to Inspections of Microbiology Pharmaceutical Quality Control Laboratories: FDA; July 1993. 7. Guide to Inspections of High Purity Water Systems, FDA; July 1993. 8. Guide to Inspections of Sterile Drug Substance Manufacturers; FDA; July 1994. 9. Guide to Inspection of Dosage Form Drug Manufacturers; FDA; Oct. 1993. 10. Compliance Policy Guide 7132a.13, Parametric Release – Drug Products Terminally Sterilized by Heat; FDA. 11. Compliance Program 7356.002, Drug Manufacturing Inspections. 12. Compliance Program 7356.002C, Radioactive Drugs. 13. Compliance Program 7356.002M, Inspection of Licensed Biological Therapeutic Drug Products. 14. Investigations Operations Manual 15. Guide to the International Inspections and Travel 16. Regulatory Procedures Manual 17. Restricted Access Barrier Systems (RABS) for Aseptic Processing ISPE Definition; ISPE; August 16 2005.; 18. ISO 17665 Moist Heat Sterilization. 19. ISO 14644 Cleanrooms and Associated Controlled Environments. 20. ISO 14698 Cleanrooms and Associated Controlled Environments- Biocontamination Control. 21. PDA Technical Report No. 1 (Revised 2007) Validation of Moist Heat Sterilization Processes: Cycle Design, Development, Qualification and Ongoing Control. ===== PAGE 36 ===== PROGRAM 7356.002A PAGE 36 of 38 22. PDA Journal of Pharmaceutical Science & Technology; Vol. 49, No. 6; November – December 1995 Performance of Blow/Fill/Seal Equipment under Controlled Airborne Microbial Challenge. 23. PDA Technical Report 51 (2010) Biological Indicators for Gas and Vapor-Phase Decontamination Processes: Specifications, Manufacture, Control and Use. 24. PDA Technical Report No. 22, revised 2011, Process Simulation for Aseptically Filled Products. 25. PDA Technical Report No. 28, revised 2006, Process Simulation Testing for Sterile Bulk Pharmaceutical Chemicals. 26. PDA Technical Report #26, 2008, Sterilizing Filtration of Liquids. 27. Bacterial endotoxins – Test Methodologies, Routine Monitoring, and Alternatives to Batch Testing. ANSI/AAMI ST 72:2002/ (R) 2010, Association for the Advancement of Medical Instrumentation. 28. CGMP Q&As. FDA website. 29. Sterility Analytical Manual (SAM); FDA May 2012. ### 6.2 ATTACHMENTS A “Inspections: Points to Consider” This attachment includes a list of questions intended to be an aid in conducting inspections and obtaining information needed to assess a firm’s operations. This list of questions and/or considerations is not intended to be an all inclusive or an exhaustive list of concerns. They are intended to assist focusing of the inspection and include areas worthy of consideration and evaluation during an inspection. The answers do not have to be reported in the EIR unless they are relevant. The list of questions covers: Moist Heat Sterilization; Dry Heat Sterilization / Depyrogenation; Aseptic Filling; Lyophilization; Isolators; Environmental Monitoring; and Biological Indicators. CDER welcomes feedback and any additional questions to this list. ### 6.3 CONTACTS Office of Regulatory Affairs (ORA) For technical questions concerning inspections contact: Office of Regulatory Affairs (ORA) Office of Medical Products and Tobacco Operations (OMPTO) Division of Medical Products and Tobacco Program Operations (DMPTPO) Telephone number: 301-796-0358 Email: ORAHQDrugInspectionPOC@fda.hhs.gov For questions concerning particulate matter in injectables analysis and appropriate testing laboratory contact: Office of Regulatory Affairs (ORA) Office of Regulatory Science (ORS) Medical Products and Tobacco Scientific Staff (MPTSS) ===== PAGE 37 ===== PROGRAM 7356.002A PAGE 37 of 38 Bruce Harris Telephone number: 301-796-3030 E-mail: Bruce.Harris@fda.hhs.gov For questions concerning microbiological analysis, sterility issues and related sampling concerns contact: Office of Regulatory Affairs (ORA) Office of Regulatory Science (ORS) Medical Products and Tobacco Scientific Staff (MPTSS) Angele Smith Telephone number: 301-796- 4200 E-mail: Angele.smith@fda.hhs.gov Center for Drug Evaluation and Research (CDER) CGMP or any Quality-Related Policy Questions For CGMP or any quality-related policy question, technical or scientific questions or information needs, including questions about this program, please send an email to the following address and it will be handled as a top priority: CDER-OPQ-Inquiries@fda.hhs.gov Enforcement-Related Guidance or Policy For enforcement-related guidance or policy, including evidence need and sufficiency, citations, and case evaluation/recommendation advice, please send an email to the following address and it will be handled as a top priority: CDER OMQ Compliance Policy: CDEROMQCompliance@fda.hhs.gov Labeling Requirements and Policies Office of Unapproved Drugs and Labeling Compliance, see intranet home page for contacts [CDER | Office of Compliance | Office of Unapproved Drugs and Labeling Compliance] Registration and Drug Listing Requirements CDER Office of Compliance, see “CDER: Who’s the Lead” intranet page for contacts [CDER | Office of Communications | CDER: Who’s the Lead] [end Part VI] ===== PAGE 38 ===== PROGRAM 7356.002A PAGE 38 of 38 PART VII - CENTER RESPONSIBILITIES A. COMPLIANCE The CDER Office of Product Quality (OPQ), Office of Surveillance (OS) will evaluate the operations under this Compliance Program. Reports of these evaluations will be shared with the ORA Headquarters offices, field offices and CDER headquarters offices. The Center reviews enforcement recommendations and provides the agency’s technical decisions in coordination with District Offices and Office of Chief Counsel B. DRUG SHORTAGES If a violative conditions are identified that may result in a shortage, field staff should notify CDER drug shortage staff at DrugShortages@CDER.fda.gov and ensure the company also contacts this staff. This notification should occur as soon as the District becomes aware of a possible shortage or through communication with the firm. CGMPs are a preventive system intended to preclude to the occurrence of critical product defects and loss of assurance of quality. A warning letter is an advisory action meant to notify a manufacturer that significant violative conditions compromising the assurance of quality, safety, and/or efficacy were observed and must be promptly corrected by an appropriate and timely action plan. In situations where the firm’s corrective actions may reduce the supply of medically necessary products, the agency will work closely with the firm to assure the medically necessary drugs remain available and the CGMP deficiencies are corrected in a timely manner. [end Part VII] ===== PAGE 39 ===== PROGRAM 7356.002A ATTACHMENT A 2012–CPGM-CDER-001 ATT. A PAGE 1 of 16 TRANSMITTAL # FORM FDA 2438g (electronic-02/2003) Inspections: Points to Consider Below is an extensive list of questions provided as an aid in conducting inspections and obtaining information needed to assess a firm’s operations. o This list of questions and/or considerations is not intended to be an all inclusive or an exhaustive list of concerns. They are intended to assist focusing of the inspection and include areas worthy of consideration and evaluation during an inspection. o The answers do not have to be reported in the EIR unless they are relevant. TOPICS: Moist Heat Sterilization Dry Heat Sterilization / Depyrogenation Aseptic Filling Lyophilization Isolator Barrier Technology Environmental Monitoring (Non-viable) Environmental and Personnel Monitoring – Microbiology Biological Indicators. CDER welcomes feedback and any additional questions to this list. MOIST HEAT STERILIZATION Reference: PDA Technical Report No. 1 Revised 2007 Validation of Moist Heat Sterilization Processes: Cycle Design, Development, Qualification and Ongoing Control; and General. 1. Who is the manufacturer of the steam sterilizer (autoclave)? 2. What is the model number, age, and internal volume of the autoclave? 3. What is the sterilizing agent? (e.g., steam, air over pressure, superheated water, gamma irradiation)? 4. If jacketed, what pressure/temperature is maintained in the jacket as opposed to the chamber? 5. What types of vent filters are used and how often are they integrity tested? 6. Are vent filters hydrophobic? Are the vent filter housings heated to prevent condensation? 7. Are cycles controlled manually or automatically? 8. What type of monitoring and controlling sensors are used (e.g., mercury-in-glass thermometer, thermocouple, RTD, pressure gauge)? 9. How are these sensors calibrated? Are the standards NIST traceable (or traceable to a National standards for foreign firms), where appropriate? 10. Is the autoclave equipped with a steam spreader (more than one steam entry line would be considered in this category)? 11. If more than one autoclave is used by the firm, what is the system's capacity for steam production in relation to all autoclaves being in operation at the same time? ===== PAGE 40 ===== PROGRAM 7356.002A ATTACHMENT A 2012–CPGM-CDER-001 ATT. A PAGE 2 of 16 TRANSMITTAL # FORM FDA 2438g (electronic-02/2003) 12. What are the sterilization cycle parameters? (Compare Master Process Record / SOP specifications against processing records completed for selected drug products) 13. What are the firm's specifications and observed parameters for: • Time • Temperature • Pressure (psi, in. Hg) 14. Where is the cycle controller sensor located? 15. How are each of the sterilization (#13) parameters monitored? Are the come-up times for chamber temperature during sterilization reproducible when compared to the come-up time achieved in validation studies? 16. Is the slowest to heat spot ("cold spot") in each load monitored during each autoclave cycle? 17. Have any changes in the steam sterilization system occurred since the last EI? Have these changes been evaluated for the need for re-validation? 18. Is clean steam being used (control of bacterial endotoxin)? Validation. 19. Does the firm have written procedures for validation that include • Design Objectives • Installation qualification (IQ) of equipment • Operational qualification (OQ) of equipment • Performance qualification (PQ) with product (maximum and minimum load submitted in the application, and any changes after) • Description of circumstances requiring revalidation of the system • Procedures for revalidation 20. Does validation documentation include the following? A. Empty chamber / loaded chamber heat distribution studies: o Number of runs? o Was cold spot determined? o Allowable variation? o Actual variation found? o What is the worst-case load? B. Heat penetration studies o For each type of loading pattern/for each container size utilized? ===== PAGE 41 ===== PROGRAM 7356.002A ATTACHMENT A 2012–CPGM-CDER-001 ATT. A PAGE 3 of 16 TRANSMITTAL # FORM FDA 2438g (electronic-02/2003) o Number of runs per pattern? o Was the "cold spot" determined for each pattern? o Is the established load configuration submitted in the application followed and/or reportable changes submitted as appropriate? 21. What type of temperature measurement system was used? Does it provide a separate printed reading for each thermocouple? 22. What type of temperature sensors were used, and were they calibrated before and after each run? 23. If biological indicators were used during validation runs: • Type of indicator (spore strip, inoculated product, ampule) • Source of indicator • Microorganism used, including concentration and D value • Were BIs used in an "end point" or "count reductions" mode? If any positive BIs were found (when not expected), what was the firm's response? 23. In the event a heat distribution or penetration variance was disclosed during the studies, how did the firm correct or allow for it? 24. Has the firm determined lag times for all container sizes/mass, product viscosities, etc. and adjusted their cycles accordingly? DRY HEAT STERILIZATION / DEPYROGENATION Dry heat sterilizers are used, primarily, to sterilize and depyrogenate glass containers for injectable drug products. Both dry heat ovens and dry heat tunnels are used. An oven is a batch process and, at the end of the cycle, the sterile vials are manually removed from the oven, transported and then manually loaded onto the filling line. A dry heat tunnel uses a continuous, integrated process. In a tunnel, the vials move on a belt from the wash processing through a heating zone where the vials are sterilized and depyrogenated to a cooling zone and then directly into the Class 100 area of a filling line. Typically, firms validate the depyrogenation of the glassware rather than the sterilization cycle. This is based on the fact that it is generally more difficult to remove or denature pyrogenic substances than microorganisms. Components that have undergone heat depyrogenation are rendered sterile. General. 25. Determine what types of dry heat sterilizers are used (ovens, tunnels)? 26. Determine the location of the heat source. The heating element/device that generates the depyrogenation temperature can affect the HEPA filters and their ability to provide the desired filtration for non-viable particles. For example, the high temperatures create expansion and contraction of the HEPA filters and filter housing, which can compromise the integrity and functionality of the HEPA filters. 27. How is the heat distributed in the oven or tunnel (fan or convection)? ===== PAGE 42 ===== PROGRAM 7356.002A ATTACHMENT A 2012–CPGM-CDER-001 ATT. A PAGE 4 of 16 TRANSMITTAL # FORM FDA 2438g (electronic-02/2003) 28. Where are the HEPA filters located in the oven or tunnel? What zones in a tunnel are supplied with HEPA filtered air (supply, heating, cooling zones)? Does the cool down section of the tunnel provide a Class 100 conditions to ensure the sterility of the containers are maintained? What zones are controlled as Class 100 areas? 29. Due to thermal dynamics (high temperature of >360 degree C leads to the expansion and contraction of the filter housing), the HEPA filter normally undergoes integrity testing every 6 months. However, depending on the amount of usage of the depyrogenation tunnel and data obtained from particle monitoring in the vicinity outside the heat tunnel, integrity testings may need to be conducted on a more frequent basis. How does the firm assure integrity of the HEPA filters? How often are HEPA filters changed? 30. Are non-viable particle counts taken in hot air tunnel? Non-viable particle measurement for the Class 100/ ISO-5 zone of the depyrogenation tunnel are not done during routine operation because of high temperature. However, periodic measurement of non-viable in ISO 5 area should be verified and they are normally measured prior to and subsequent to the manufacture of a batch/campaign and at ambient temperature. 31. Are the sterilization / depyrogenation cycles controlled manual or automatically? 32. What type of monitoring and controlling sensors are used (e.g., thermocouple, RTD, pressure gauge, belt speed indicators)? How often are they calibrated? Parameters. 33. What are the sterilization / depyrogenation cycle parameters or equipment settings? Compare master production record / SOP specifications and processing records for specific representative products. 34. What are the firm's specifications for time, temperature, belt speed, and pressures if applicable? 35. What are the critical parameters? How were they established? How does the firm assure the critical parameters are met for each lot or cycle? 36. Where are the sensors for the cycle controllers located? 37. How are each of the above parameters monitored? Are any of the parameters not monitored? Are the critical parameters alarmed in continuous systems, such as those used in tunnels? What is done when there is an alarm? 38. How does the firm assure that all critical parameters are met for each cycle in an oven or for the continuous run of the tunnel? 39. Do dry heat tunnels have alarms to alert operators if critical parameters (heat, belt speed, pressure) are not met? Are the alarms documented? Did the conditions that caused the alarm require the implementation of change controls and did they impact the validated process? ===== PAGE 43 ===== PROGRAM 7356.002A ATTACHMENT A 2012–CPGM-CDER-001 ATT. A PAGE 5 of 16 TRANSMITTAL # FORM FDA 2438g (electronic-02/2003) 40. Have any changes in the dry heat sterilization / depyrogenation system occurred since the last inspection? Have these changes been evaluated for the need for revalidation? Validation. 41. Does the firm have written procedures for qualifying the dry heat sterilizers that include: • Design Objectives • Installation qualification of equipment • Operational qualification of equipment • Performance qualification with product • Description of circumstances requiring re-validation and procedures 42. Does validation documentation include heat distribution / penetration studies? • What is the firm's allowable temperature variation and the actual variation found in production? • What type of temperature measurement system was used? • Was calibration performed before and after the validation? • If dry heat sterilizer is an oven, was the slowest to heat area determined? 43. How was the depyrogenation cycle validated? • Was a known amount of endotoxin added to vials? • Was the endotoxin allowed to dry on the vials? • Was validation conducted with recovery tests to assure the spiked endotoxin can be recovered? Were the vials challenged with enough endotoxin to allow calculation of a 3-log reduction? • What cycle or equipment settings were used in the validation runs? • Was a 3 log reduction of endotoxin achieved? 44. Are the depyrogenation cycles for all vials validated or does the firm use a matrix approach? If a matrix approach (vial sizes/mass) is used, what criteria are used to select the worst case challenges to the system? Are all vials types and sizes bracketed? 45. Have the dry heat sterilizer cycles or equipment settings changed since the validation studies were completed? Compare validation studies, current SOPs and processing records for recent batches. ASEPTIC FILLING 46. When observing personnel during production, do operators practice proper cleanroom behaviors as specified in established cleanroom SOPs? 47. Can you observe the aseptic filling processes without going into the clean room (i.e., through window or TV monitor)? ===== PAGE 44 ===== PROGRAM 7356.002A ATTACHMENT A 2012–CPGM-CDER-001 ATT. A PAGE 6 of 16 TRANSMITTAL # FORM FDA 2438g (electronic-02/2003) A. If yes, watch / observe the aseptic filling processes from preparation of bulk liquid product to filling and sealing of final dosage form, including the environmental monitoring performed in critical areas during actual production. B. If not, consider observing the aseptic filling inside the clean room, for example, via a Class 10,000 (ISO-7) area. Prior to entry, consult the District. o Do personnel enter and perform interventions at the critical Class 100 (ISO 5) areas of the filling lines? If so, how are such entries recorded? o How is this done (full body entry, hands only)? o Why? o Is this done routinely or infrequently? o Are proper aseptic techniques used? [Reference: FDA 2004 Aseptic Processing Guidance, Section V.A.] o Do hands or arms go over open vials for sterile components? If yes, are the vials discarded? 48. Does the firm have written procedures describing aseptic filling of drug products? Does it include discussions of proper aseptic techniques and acceptable techniques for performing interventions into the Class 100 areas? 49. Review trend reports of the non-viable, viable and personnel monitoring data. • Have any trends been identified by the firm? If yes, what is done? • Are investigations done of out of limit results? Aseptic Filling Validation. Reference: FDA’s 2004 Aseptic Processing Guidance, Section IX 50. How does the process used for media fill compare to the aseptic filling of commercial drug products? Does the firm accurately evaluate the production operation on a routine basis (changes over time) against the media fill design? Does the firm have detailed procedures that describe the media fill process, including frequency, challenge conditions, personnel participation, container / closures, interventions, duration of fill, reconciliation of vials, acceptance criteria, incubation, examination after incubation, actions to take if positive growth is found, etc? 51. Request a summary of all media fills conducted since last inspection, including lot identification, fill dates, production lines, number of units filled, number of units incubated, number of vials with no growth, number of vials with positive growth, microbial identification for any containers with growth, disposition of media fill units, etc. • Have media fills been done at the frequency described in the procedure? • Have any media fills showed positive growth? • Have any media fills failed to meet acceptance criteria? ===== PAGE 45 ===== PROGRAM 7356.002A ATTACHMENT A 2012–CPGM-CDER-001 ATT. A PAGE 7 of 16 TRANSMITTAL # FORM FDA 2438g (electronic-02/2003) 52. Are procedures followed when positive growth is found in media filled vials? Are investigations conducted of all positive growth found in media filled vials? What is done when a media fill fails to meet acceptance criteria? Review investigations of any positive growth. 53. Are media fills performed on all shifts (e.g., representative of shift operations in a campaign)? Do media fills include shift changes and breaks that occur during routine production? 54. When can media fills be aborted or units not incubated? Would production lots be rejected if the same conditions existed during filling? 55. Are all personnel included in the media fill program? Does this include set up personnel and mechanics who work on the aseptic filling lines? What system does the firm have for assuring all personnel are included? 56. If end-line filters are used in actual manufacture, are they also used during media fills? 57. What size vials or ampules are used for media fills? Evaluate justification for selecting worst case challenge if firm does not perform media fills using all the container / closure configurations filled on the line. 58. Are vials inverted before incubation to assure media touches all inner surfaces? 59. How does the firm conduct media fills for products that are filled into amber or opaque containers? 60. How does the firm assure that all integral vials are incubated? How does the firm handle filled vials removed during the run because of interventions? 61. Do media fills include interventions that occur during routine production? Are there written procedures specifying removal of media fill units (type of intervention and number of units removed) corresponding to the practice of a routine production run? Did you observe any interventions during the filling of routine production lots that are not included in media fills? 62. Does the duration of a media fill approximate the duration of a routine production lot? If not, evaluate firm’s justification for running shorter media fills? 63. What is the microbial growth medium? 64. Are growth promotion studies performed on each type of medium used? 65. Are growth promotion studies conducted every time a media fill is done? 66. When are the growth promotion studies performed (before/after filling; after incubation; etc.)? 67. What organisms are used to perform the growth promotion tests? Are any environmental organisms used? 68. What temperatures and incubation times are used to incubate media filled vials? ===== PAGE 46 ===== PROGRAM 7356.002A ATTACHMENT A 2012–CPGM-CDER-001 ATT. A PAGE 8 of 16 TRANSMITTAL # FORM FDA 2438g (electronic-02/2003) 69. Are microorganisms from positive vials identified to genus and species? Are such microorganisms correlated to those found during environmental monitoring? 70. Is an investigation done when cracked vials are found after incubation begins? 71. When and where are the media filled vials examined? 72. Who performs the examination of media filled vials? If production employees perform the examination, have they been trained to recognize all types of microbial growth. Is a microbiologist present when the examination is done? 73. What incubators are used to incubate media filled vials? How is the temperature controlled and monitored? Have tests been done to determine if the temperature is uniform throughout the incubator? LYOPHILIZATION (FREEZE-DRYING) Reference: Guide to Inspections of Lyophilization of Parenterals; FDA; July 1993 General. 74. Who is the manufacturer of the lyophilizer? 75. Describe the heating and cooling systems used in the lyophilizer; the vacuum system; gas that is used to break the vacuum and whether it is sterile; and the temperature controlling system. 76. How are the vials transported from the filling line to the lyophilizer? How are Class 100 (ISO 5) conditions maintained during transport, loading, and unloading of the lyophilizer? 77. Are the loading and unloading of the vials automated or manual? 78. How is the sealing of vials (final seating of stoppers) performed? 79. If the stoppering is performed automatically in the chamber at the end of the cycle, is it under vacuum? If not under vacuum, what gas is used and how is it sterilized? 80. If the vials are stoppered outside of the chamber, how is the lyophilized product protected from contamination during transport to the stoppering station and during the stoppering operation? 81. Describe the chamber clean-up procedures between batches of the same product and between different products (including sterilant / cleaning agents used, monitoring for sterilant residue where appropriate, and exposure cycle). 82. Past history has shown that the lyophilizer condenser can be a source of contamination and an assessment of the lyophilization process should include an inspection of the condenser. How is lyophilization cycle monitored/ documented and reviewed? ===== PAGE 47 ===== PROGRAM 7356.002A ATTACHMENT A 2012–CPGM-CDER-001 ATT. A PAGE 9 of 16 TRANSMITTAL # FORM FDA 2438g (electronic-02/2003) Lyophilization Validation – Sterilization of Chamber. 81. How is the lyophilization chamber sterilized? How are all surfaces, such as all surfaces of moving shelves, exposed to steam? 82. When is the lyophilization chamber sterilized? What is explanation / justification if it is not done between each batch? 83. How are sterilization cycles controlled (manual, programmed)? How are cycles monitored during production? 84. Has the sterilization of the lyophilization chamber been validated? Have the slowest to heat surfaces in the chamber been determined and challenged in the validation runs? 85. Review current procedures and sterilization records for production lots. Are the cycle parameters the same as those used during validation? Do production cycles meet the validated cycle parameters? Lyophilization Validation – Aseptic Handling. 86. Is the aseptic handling of lyophilized products validated by media fills? 87. In the aseptic process, is lyophilization simulation performed during media fill? 88. Is the maximum amount of time the vials are held prior to lyophilization simulated during media fills? If vials are not sealed in lyophilization chamber, is the maximum hold time prior to stoppering simulated in media fills? 89. During validation, what level of vacuum is pulled on the lyophilization chamber? 90. How long do media fill vials remain in the lyophilization chamber under vacuum? How does this compare to commercial lots? 91. Does the process simulation result in freezing of the media? Note that this process simulation should not include freezing of the media. 92. Is environmental monitoring performed during loading of the lyophilizer both during production and as well as during validation? 93. Does the firm have data on growth promotion of the media? Are growth promotion tests done on vials after incubation is completed? 94. Is environmental monitoring performed during unloading of the chamber during production as well as during media fill validation? 95. What is used to break the vacuum during media fills (nitrogen, air, other gas)? ===== PAGE 48 ===== PROGRAM 7356.002A ATTACHMENT A 2012–CPGM-CDER-001 ATT. A PAGE 10 of 16 TRANSMITTAL # FORM FDA 2438g (electronic-02/2003) Lyophilization Validation – Process. 98. Has the firm validated the lyophilization cycle (e.g., time, rate of heat input, temperatures, eutectic melting point) for each product? Review validation records for selected drug products with different physical and chemical characteristics. 99. Review lyophilization production records for the same products. Are the cycle parameters and observed results within the validated cycles? 100. What are the firm’s criteria for acceptable vs. unacceptable runs, including general appearance, cake appearance, meltback, reconstitution time, moisture, etc.? 101. Has the firm performed equipment qualification, preventative maintenance, critical instrument calibration, and cleaning validation? Lyophilization of sterile API: The aseptic process may include either a manual or automated transferring process, or a combination of both, to transfer the lyophilized API out of the lyophilizer and into an SIP holding vessel or transfer tank. It is equally important to observe and assess the manual operations of the aseptic lyophilization process and assure that similar operations are performed during the media fill processing steps for the API. ISOLATOR BARRIER TECHNOLOGY Reference: Appendix 1 of FDA’s 2004 Aseptic Processing Guidance NOTE: Methods (e.g., hydrogen peroxide, peracetic acid) used to decontaminate isolator barriers are capable of rendering surfaces free of viable organisms, but lack the capabilities of steam sterilization. While these agents do not effectively penetrate obstructed or protected surfaces, validated systems are highly effective at assuring contamination-free internal isolator surfaces. 102. Determine: • Model of isolator or barrier, and materials of construction • Type of isolator (open or closed)? • Airflow (turbulent, unidirectional)? • Classification of surrounding room environment • Number and location of gloves or half-suits • Attire worn by operators (e.g., are sterile gloves worn under isolator gloves?) • Operating parameters (pressures, air velocities, temperature, humidity) 103. Is a written maintenance program in place which requires routine documented checks or tests of gloves, half-suits, door seals, etc. for integrity? What type of tests/checks are done and how frequently? ===== PAGE 49 ===== PROGRAM 7356.002A ATTACHMENT A 2012–CPGM-CDER-001 ATT. A PAGE 11 of 16 TRANSMITTAL # FORM FDA 2438g (electronic-02/2003) 104. Do written procedures specify glove replacement frequency? If so, what is the frequency and is the SOP followed? 105. Does the isolator maintain continuous positive pressure and at sufficient levels? 106. How are materials transferred into and out of the isolator? How robust are the transfer mechanisms? 107. Are the equipment and surfaces that have direct contact with sterile products and components sterilized by heat. Does it achieve a minimum of a six-log reduction of the BI spores? 108. What method is used to decontaminate the inner surface of the isolator barrier (e.g., vapor hydrogen peroxide, steam hydrogen peroxide, chlorine dioxide, etc.)? Determine decontamination parameters. 109. Did the surface decontamination validation study sufficiently address the ability of the sterilant to disperse throughout the chamber and reach all surfaces? Did the decontamination process include the use of Chemical Indicators (CI) to determine the presence or absence of the VHP on the work surfaces and/or the worst case locations to decontaminate? The CI can assists in the evaluation process by providing useful qualitative data. Were replicate BIs placed throughout the isolator, including the most difficult to reach locations (e.g., underneath any items remaining in isolator during sterilization). Are the most difficult to sterilize materials evaluated? 110. What is the isolator decontamination frequency and is it justified by validation data? 111. Is a decontamination cycle performed after a power failure or pressure reversal or other unanticipated breach of system integrity? 112. How often is the isolator decontamination cycle revalidated? 113. Does the written environmental monitoring program include routine tests for nonviable particles, as well as an appropriate number of microbial tests (e.g., active air and surface samples; gloves samples) during each campaign? Evaluate the tests performed and the testing frequencies. Testing Isolators (Sterility test). 114. Have any false positives been identified in the laboratory isolator barrier (this should be an exceedingly rare occurrence)? Were the false positive investigated to determine and correct the cause. ENVIRONMENTAL MONITORING – Non-viable Reference: FDA’s 2004 Aseptic Processing Guidance, Section IV. 115. Is the air supplied to critical areas (exposed product / filling areas) filtered through HEPA filters under positive pressure? ===== PAGE 50 ===== PROGRAM 7356.002A ATTACHMENT A 2012–CPGM-CDER-001 ATT. A PAGE 12 of 16 TRANSMITTAL # FORM FDA 2438g (electronic-02/2003) 116. Is the air flow in critical areas unidirectional when delivered to the point of use? At what velocity? Is velocity determined at the critical work height and at the filter face? Air flow pattern evaluations (smoke studies) under dynamic conditions are performed to visualize and demonstrate unidirectional air flow within a designated area/room [e.g., Class 100 & 10,000 (ISO5 & ISO7)]. The smoke studies may also reveal air turbulences and air eddies that could be a vector assisting the dissemination of microbial and/or non-viable contamination within critical manufacturing areas. 117. How is the air filtered that is supplied to critical areas (where unsterilized product, in-process materials, and container/closures are prepared)? 118. What are the firm's air quality classifications for the following areas: • Compounding • Equipment preparation • Any area where product or sterilized components are exposed • Areas where aseptic connections are made • Filling lines • Room surrounding filling lines • Capping (crimping) area 119. How often are HEPA filters integrity tested? What test method is used? What is done if leaks are found? If done by an outside firm, are results reviewed by on-site personnel including the quality unit? 120. How often are air flow velocities checked for each HEPA filter? What are the air velocity specifications? What is done if velocity readings are out of specification? 121. Does the firm have a written monitoring program for classified areas that includes scientifically sound sampling schedules; descriptions of sampling locations and frequency of sampling? How were the locations selected? 122. What type of instrument is used to check non-viable particle counts in the classified areas? Is the air sampled continuously? If continuous, is there an alarm when counts exceed pre-set limits or detects cleanroom doors open for an extended time? What is done in response to the alarms? Is there an alarm log? Are permanently installed sensors used or portable units that are taken into and out of the critical areas? What is done if counts meet or exceed alert and action limits? 123. What are the pressure differential requirements in the sterile core area? Does this assure an air cascade from most clean area to least clean air (by air classification)? 124. How are pressure differentials monitored? Is a continuous monitoring system used? If yes, does it include alarms so operators are aware of excursions? Are alarm conditions documented (alarm log)? What is done in response to an alarm? How long must a condition exist before an alarm sounded? ===== PAGE 51 ===== PROGRAM 7356.002A ATTACHMENT A 2012–CPGM-CDER-001 ATT. A PAGE 13 of 16 TRANSMITTAL # FORM FDA 2438g (electronic-02/2003) 125. How are temperature and humidity monitored? What is the acceptable range? What is done if the reading is outside of the range? 126. How are environmental excursions (readings that meet or exceed alert and action levels) handled? Are the excursions investigated to determine impact on product, root cause and needed corrective actions? ENVIRONMENTAL AND PERSONNEL MONITORING – Microbiology Reference: FDA’s 2004 Aseptic Processing Guidance, Sections V and X.A Air. 127. Does the firm have an effective Environmental Monitoring (EM) Program in place? What is the purpose and scope of the EM Program? Are EM sampling locations strategic, based on product contamination risk of the process and operation? Are the microbial alert and action levels based on the historical EM data derived from the manufacturing operations, support utilities and personnel practices performed at the manufacturing site? What is the frequency of microbiological sampling of air using "active" samplers (systems that sample a known volume of air) in various locations, such as: • Areas where product or sterile components are exposed to the environment • Filling areas • Loading areas for lypohilizers • Surrounding areas 128. What are the established microbial alert and action levels or limits for quantitative air samples? What is the length of the sampling period? Is sampling done during production or at rest? 129. What type of active air sampling equipment is used (centrifugal, impaction, membrane)? Is the sampling equipment calibrated? What is the efficiency of the active air sampler? 130. Does the firm have data on the ability of these samplers to recover organisms without deleterious effect on survivability such as through impact or desiccation of the media? 131. What is the actual volume of air sampled per location? 132. Are settling plates used? What is the length of exposure period? Sampling frequency? Locations (including proximity to critical operations)? Microbial limits? Surfaces. 133. Are there written procedures that describe the monitoring of surfaces in the clean rooms? Does it describe locations, frequency and sampling techniques? 134. What surfaces are sampled in the critical (Class 100 / ISO 5) areas? Are critical surfaces included (those that touch the sterile product or sterile components)? ===== PAGE 52 ===== PROGRAM 7356.002A ATTACHMENT A 2012–CPGM-CDER-001 ATT. A PAGE 14 of 16 TRANSMITTAL # FORM FDA 2438g (electronic-02/2003) 135. When are surface samples taken? Are critical surfaces only sampled at the end of the operation? 136. What is the frequency of sampling surfaces? 137. What types of samples are collected at each location (RODAC plate, swab samples)? 138. What are the alert and action levels / limits for the microbial sampling of critical surfaces, surfaces in Class 100 areas and surfaces in other classified areas? How were the levels / limits established? What is done when the samples meet or exceed alert and action levels? Personnel. 139. Are there specific programs for training personnel who work in classified and aseptic processing areas? Does the program include microbiological testing or qualifying employees before they are allowed to work in these areas? Does the program include prequalification requirements? 140. How often is monitoring performed on filling room personnel? Is it done at least upon existing the cleanroom (e.g., per shift)? How often are gloves (hands) sampled? How often are gowns sampled? Is any sampling done after interventions are performed? 141. Who performs the sampling of personnel? Is it self-sampling? Is the sampling performed by another production employee, a microbiologist, technician or other quality control employee? 142. What are the firm's alert and action levels / limits for personnel monitoring? How were the levels / limits established? What is done if the sample results reach or exceed the alert and action limits? 143. Do employees spray their hands with sanitizer or disinfectant before the sample is taken? General. 144. What are the microbiological growth media used for environmental and personnel monitoring samples? 145. Are the media used in the viable monitoring program shown to be capable of detecting molds and yeasts as well as bacteria by means of growth promotion tests? 146. Is anaerobic monitoring ever performed? When? 147. Are inactivators used for antibiotics or other bactericidal / bacteriostatic substances? Has the firm shown that these are effective? Are records available? 148. When are recovered microorganisms identified? To what level (genus, species)? 149. What are the incubation times and temperatures? 150. How are environmental and personnel monitoring data trended? How often are trend reports prepared? How often are they reviewed? Who reviews the trend reports? What type of action is taken based on review of trend reports? ===== PAGE 53 ===== PROGRAM 7356.002A ATTACHMENT A 2012–CPGM-CDER-001 ATT. A PAGE 15 of 16 TRANSMITTAL # FORM FDA 2438g (electronic-02/2003) 151. Are environmental and personnel monitoring samples that exceed action levels investigated to determine product impact, cause and needed corrective actions? What is done when an alert level is exceeded? Review and assess the EM trending data, which will provide a good indication if the viable and non- viable particles are maintained within the established levels or drifting out of control. What are the causes of the aberrant events? Were corrective actions and preventive measures taken to preclude the reoccurrence of the viable and non-viable particle anomalies? BIOLOGICAL INDICATORS (BIs) In sterile drug manufacturing, BIs are typically used to validate the cycles used for terminal sterilization, sterilization of equipment and components. BIs are also used to validate SIP systems used to sterilize lyophilizers, processing tanks, sterilizing filters, and product lines and systems used to decontaminate surfaces in isolators. 152. What type of indicator is used (e.g., inoculated carrier, inoculated product, inoculated simulated product, etc.)? Are BIs inoculated into the components (i.e., stoppers) used whenever possible? What are their corresponding D values? Is the sterilization cycle adequate corresponding to the D value of the BI? 153. If the source of the indicator is commercial, what is the brand name and manufacturer? What labeling is received with the BI? If the BI is prepared in-house, determine the supplier of the organism, how the BI is propagated and stored, and the method of preparation? 154. What organism is used (Genus, species)? Is it the appropriate microorganism used for sterilization? 155. What is the challenge level of the biological indicator prior to exposure to sterilant? 156. Does the firm verify viable spore count on each lot of BIs before use in validation? 157. Does the firm or the BI labeling claim to meet USP performance criteria for steam or ETO biological indicators? 158. Does the firm perform USP testing on each lot of BIs received? 159. What is the approximate D-value of the biological indicator? Is this verified prior to validation? 160. How many BIs are used per sterilizer load? 161. What procedure is used to assay the indicators after exposure? What growth media is used? What are the optimal and actual incubation time and temperature for the BI (compare to COA received with the BI)? 162. How are the BIs prepared for sterilization? ===== PAGE 54 ===== PROGRAM 7356.002A ATTACHMENT A 2012–CPGM-CDER-001 ATT. A PAGE 16 of 16 TRANSMITTAL # FORM FDA 2438g (electronic-02/2003) 163. Are biological indicators located in the most difficult to sterilize product sites (explain)? How are these locations determined? 164. Is there a diagram of the distribution of biological indicators in the loading pattern(s) used? 165. What is the elapsed time (hrs.) between removing indicators from the sterilizer and testing? Are there time limits established for this period? What happens if they are exceeded? 166. What is done if positive BIs are found after sterilization? 167. Describe biological indicator storage conditions: A. Type of room, cabinet, etc. (if stored in freezer or refrigerator, state if frost-free) B. Temperature C. Relative humidity (if known) D. Compare to literature received with BI or written procedures 168. Does the firm use chemical process monitor(s) to indicate cycle exposure or to measure one or more cycle parameters? --- ### Document: FDA ProcessVal Complete (FDA) # FDA Guidance for Industry: Process Validation: General Principles and Practices (January 2011) [PAGE 4] Guidance for Industry1 Process Validation: General Principles and Practices This guidance represents the Food and Drug Administration’s (FDA’s) current thinking on this topic. It does not create or confer any rights for or on any person and does not operate to bind FDA or the public. You can use an alternative approach if the approach satisfies the requirements of the applicable statutes and regulations. If you want to discuss an alternative approach, contact the FDA staff responsible for implementing this guidance. If you cannot identify the appropriate FDA staff, call the appropriate number listed on the title page of this guidance. I. INTRODUCTION This guidance outlines the general principles and approaches that FDA considers appropriate elements of process validation for the manufacture of human and animal drug and biological products, including active pharmaceutical ingredients (APIs or drug substances), collectively referred to in this guidance as drugs or products. This guidance incorporates principles and approaches that all manufacturers can use to validate manufacturing processes. This guidance aligns process validation activities with a product lifecycle concept and with existing FDA guidance, including the FDA/International Conference on Harmonisation (ICH) guidances for industry, Q8(R2) Pharmaceutical Development, Q9 Quality Risk Management, and Q10 Pharmaceutical Quality System.2 Although this guidance does not repeat the concepts and principles explained in those guidances, FDA encourages the use of modern pharmaceutical development concepts, quality risk management, and quality systems at all stages of the manufacturing process lifecycle. 1 This guidance has been prepared by the Division of Manufacturing and Product Quality, Center for Drug Evaluation and Research (CDER), in cooperation with CDER’s Office of Pharmaceutical Sciences, the Center for Biologics Evaluation and Research (CBER), the Office of Regulatory Affairs (ORA) and the Center for Veterinary Medicine (CVM) at the Food and Drug Administration. 2 To make sure you have the most recent version of a guidance, check the CDER guidance page at http://www.fda.gov/Drugs/GuidanceComplianceRegulatoryInformation/Guidances/default.htm, the CBER guidance page at http://www.fda.gov/BiologicsBloodVaccines/GuidanceComplianceRegulatoryInformation/Guidances/default.htm, or the CVM guidance page at http://www.fda.gov/AnimalVeterinary/GuidanceComplianceEnforcement/GuidanceforIndustry/default.htm . [PAGE 5] Contains Nonbinding Recommendations The lifecycle concept links product and process development, qualification of the commercial manufacturing process,3 and maintenance of the process in a state of control during routine commercial production. This guidance supports process improvement and innovation through sound science. This guidance covers the following categories of drugs: • Human drugs • Veterinary drugs • Biological and biotechnology products • Finished products and active pharmaceutical ingredients (APIs or drug substances)4 • The drug constituent of a combination (drug and medical device) product This guidance does not cover the following types of products: • Type A medicated articles and medicated feed • Medical devices5 • Dietary supplements • Human tissues intended for transplantation regulated under section 361 of the Public Health Service Act6 This guidance does not specify what information should be included as part of a regulatory submission. Interested persons can refer to the appropriate guidance or contact the appropriate Center in determining the type of information to include in a submission. This guidance also does not specifically discuss the validation of automated process control systems (i.e., computer hardware and software interfaces), which are commonly integrated into modern drug manufacturing equipment. This guidance is relevant, however, to the validation of processes that include automated equipment in processing. 3 In this guidance, the term commercial manufacturing process refers to the manufacturing process resulting in commercial product (i.e., drug that is marketed, distributed, and sold or intended to be sold). For the purposes of this guidance, the term commercial manufacturing process does not include clinical trial or treatment IND material. 4 Separate current good manufacturing practice (CGMP) regulations for drug components such as APIs (drug substances) and intermediates have not published as of the date of this guidance, but these components are subject to the statutory CGMP requirements of section 501(a)(2)(B) of the Federal Food, Drug, and Cosmetic Act (the Act) (21 U.S.C. 351(a)(2)(B)). Process validation for APIs is discussed in the FDA/ICH guidance for industry, Q7 Good Manufacturing Practice Guidance for Active Pharmaceutical Ingredients (ICH Q7), available on the Internet at http://www.fda.gov/Drugs/GuidanceComplianceRegulatoryInformation/Guidances/default.htm. Section XII of ICH Q7 describes in detail the principles for validating API processes. 5 Guidance on process validation for medical devices is provided in a separate document, Quality Management Systems – Process Validation, edition 2, See infra note 6. 6 See the FDA guidance for industry, Validation of Procedures for Processing of Human Tissues Intended for Transplantation, available on the Internet at http://www.fda.gov/BiologicsBloodVaccines/GuidanceComplianceRegulatoryInformation/Guidances/default.htm. [PAGE 6] Contains Nonbinding Recommendations FDA’s guidance documents, including this guidance, do not establish legally enforceable responsibilities. Instead, guidances describe the Agency’s current thinking on a topic and should be viewed only as recommendations, unless specific regulatory or statutory requirements are cited. The use of the word should in Agency guidances means that something is suggested or recommended, but not required. II. BACKGROUND In the Federal Register of May 11, 1987 (52 FR 17638), FDA issued a notice announcing the availability of a guidance entitled Guideline on General Principles of Process Validation (the 1987 guidance).7 Since then, we have obtained additional experience through our regulatory oversight that allows us to update our recommendations to industry on this topic. This revised guidance conveys FDA’s current thinking on process validation and is consistent with basic principles first introduced in the 1987 guidance. The revised guidance also provides recommendations that reflect some of the goals of FDA’s initiative entitled “Pharmaceutical CGMPs for the 21st Century ― A Risk-Based Approach,” particularly with regard to the use of technological advances in pharmaceutical manufacturing, as well as implementation of modern risk management and quality system tools and concepts.8 This revised guidance replaces the 1987 guidance. FDA has the authority and responsibility to inspect and evaluate process validation performed by manufacturers. The CGMP regulations for validating pharmaceutical (drug) manufacturing require that drug products be produced with a high degree of assurance of meeting all the attributes they are intended to possess (21 CFR 211.100(a) and 211.110(a)). A. Process Validation and Drug Quality Effective process validation contributes significantly to assuring drug quality. The basic principle of quality assurance is that a drug should be produced that is fit for its intended use. This principle incorporates the understanding that the following conditions exist: • Quality, safety, and efficacy are designed or built into the product. • Quality cannot be adequately assured merely by in-process and finished-product inspection or testing. 7 The 1987 guidance was prepared by a working group that included representation from the Center for Devices and Radiological Health (CDRH). Since that time, CDRH elected to reference a process validation guidance prepared in cooperation with the Global Harmonization Task Force (GHTF). The principles and recommendations in that document, Quality Management Systems – Process Validation, edition 2 (available on the Internet at http://www.ghtf.org/sg3/sg3-final.html) are also useful to consider for drug manufacturing processes. 8 See “Pharmaceutical cGMPS for the 21st Century — A Risk-Based Approach: Second Progress Report and Implementation Plan,” available at http://www.fda.gov/Drugs/DevelopmentApprovalProcess/Manufacturing/QuestionsandAnswersonCurrentGoodMan ufacturingPracticescGMPforDrugs/ucm071836.htm. [PAGE 7] Contains Nonbinding Recommendations • Each step of a manufacturing process is controlled to assure that the finished product meets all quality attributes including specifications. B. Approach to Process Validation For purposes of this guidance, process validation is defined as the collection and evaluation of data, from the process design stage through commercial production, which establishes scientific evidence that a process is capable of consistently delivering quality product. Process validation involves a series of activities taking place over the lifecycle of the product and process. This guidance describes process validation activities in three stages. • Stage 1 – Process Design: The commercial manufacturing process is defined during this stage based on knowledge gained through development and scale-up activities. • Stage 2 – Process Qualification: During this stage, the process design is evaluated to determine if the process is capable of reproducible commercial manufacturing. • Stage 3 – Continued Process Verification: Ongoing assurance is gained during routine production that the process remains in a state of control. This guidance describes activities typical of each stage, but in practice, some activities might occur in multiple stages. Before any batch from the process is commercially distributed for use by consumers, a manufacturer should have gained a high degree of assurance in the performance of the manufacturing process such that it will consistently produce APIs and drug products meeting those attributes relating to identity, strength, quality, purity, and potency. The assurance should be obtained from objective information and data from laboratory-, pilot-, and/or commercial- scale studies. Information and data should demonstrate that the commercial manufacturing process is capable of consistently producing acceptable quality products within commercial manufacturing conditions. A successful validation program depends upon information and knowledge from product and process development. This knowledge and understanding is the basis for establishing an approach to control of the manufacturing process that results in products with the desired quality attributes. Manufacturers should: • Understand the sources of variation • Detect the presence and degree of variation • Understand the impact of variation on the process and ultimately on product attributes • Control the variation in a manner commensurate with the risk it represents to the process and product Each manufacturer should judge whether it has gained sufficient understanding to provide a high degree of assurance in its manufacturing process to justify commercial distribution of the [PAGE 8] Contains Nonbinding Recommendations product. Focusing exclusively on qualification efforts without also understanding the manufacturing process and associated variations may not lead to adequate assurance of quality. After establishing and confirming the process, manufacturers must maintain the process in a state of control over the life of the process, even as materials, equipment, production environment, personnel, and manufacturing procedures change.9 Manufacturers should use ongoing programs to collect and analyze product and process data to evaluate the state of control of the process. These programs may identify process or product problems or opportunities for process improvements that can be evaluated and implemented through some of the activities described in Stages 1 and 2. Manufacturers of legacy products can take advantage of the knowledge gained from the original process development and qualification work as well as manufacturing experience to continually improve their processes. Implementation of the recommendations in this guidance for legacy products and processes would likely begin with the activities described in Stage 3. III. STATUTORY AND REGULATORY REQUIREMENTS FOR PROCESS VALIDATION Process validation for drugs (finished pharmaceuticals and components) is a legally enforceable requirement under section 501(a)(2)(B) of the Act (21 U.S.C. 351(a)(2)(B)), which states the following: A drug . . . shall be deemed to be adulterated . . . if . . . the methods used in, or the facilities or controls used for, its manufacture, processing, packing, or holding do not conform to or are not operated or administered in conformity with current good manufacturing practice to assure that such drug meets the requirements of this Act as to safety and has the identity and strength, and meets the quality and purity characteristics, which it purports or is represented to possess. FDA regulations describing current good manufacturing practice (CGMP) for finished pharmaceuticals are provided in 21 CFR parts 210 and 211. The CGMP regulations require that manufacturing processes be designed and controlled to assure that in-process materials and the finished product meet predetermined quality requirements and do so consistently and reliably. Process validation is required, in both general and specific terms, by the CGMP regulations in parts 210 and 211. The foundation for process validation is provided in § 211.100(a), which states that “[t]here shall be written procedures for production and process control designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess...” (emphasis added). This regulation requires manufacturers to design a process, including operations and controls, which results in a product meeting these attributes. 9 The statute and regulations described in section III of this guidance explain the requirement that the methods and facilities used for the manufacturing of drugs be operated and administered under control sufficient to assure that the identity, strength, purity, and quality of a drug are as they purport or are represented to possess. [PAGE 9] Contains Nonbinding Recommendations Other CGMP regulations define the various aspects of validation. For example, § 211.110(a), Sampling and testing of in-process materials and drug products, requires that control procedures “. . . be established to monitor the output and to validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product” (emphasis added). Under this regulation, even well-designed processes must include in-process control procedures to assure final product quality. In addition, the CGMP regulations regarding sampling set forth a number of requirements for validation: samples must represent the batch under analysis (§ 211.160(b)(3)); the sampling plan must result in statistical confidence (§ 211.165(c) and (d)); and the batch must meet its predetermined specifications (§ 211.165(a)). In addition to sampling requirements, the CGMP regulations also provide norms for establishing in-process specifications as an aspect of process validation. Section 211.110(b) establishes two principles to follow when establishing in-process specifications. The first principle is that “. . . in-process specifications for such characteristics [of in-process material and the drug product] shall be consistent with drug product final specifications . . . .” Accordingly, in-process material should be controlled to assure that the final drug product will meet its quality requirements. The second principle in this regulation further requires that in-process specifications “. . . shall be derived from previous acceptable process average and process variability estimates where possible and determined by the application of suitable statistical procedures where appropriate.” This requirement, in part, establishes the need for manufacturers to analyze process performance and control batch-to-batch variability.10 The CGMP regulations also describe and define activities connected with process design, development, and maintenance. Section 211.180(e) requires that information and data about product quality and manufacturing experience be periodically reviewed to determine whether any changes to the established process are warranted. Ongoing feedback about product quality and process performance is an essential feature of process maintenance. In addition, the CGMP regulations require that facilities in which drugs are manufactured be of suitable size, construction, and location to facilitate proper operations (§ 211.42). Equipment must be of appropriate design, adequate size, and suitably located to facilitate operations for its intended use (§ 211.63). Automated, mechanical, and electronic equipment must be calibrated, inspected, or checked according to a written program designed to assure proper performance (§ 211.68). In summary, the CGMP regulations require that manufacturing processes be designed and controlled to assure that in-process materials and the finished product meet predetermined quality requirements and do so consistently and reliably. 10 The Agency further explains this principle in the preamble to the final rule on “Current Good Manufacturing Practice in Manufacture, Processing, Packing, or Holding” (43 FR 45013 at 45052, September 29, 1978) (available on the Internet at http://www.fda.gov/cder/dmpq/preamble.txt). [PAGE 10] Contains Nonbinding Recommendations IV. RECOMMENDATIONS In the following sections, we describe general considerations for process validation, the recommended stages of process validation, and specific activities for each stage in the product lifecycle. A. General Considerations for Process Validation In all stages of the product lifecycle, good project management and good archiving that capture scientific knowledge will make the process validation program more effective and efficient. The following practices should ensure uniform collection and assessment of information about the process and enhance the accessibility of such information later in the product lifecycle. • We recommend an integrated team approach11 to process validation that includes expertise from a variety of disciplines (e.g., process engineering, industrial pharmacy, analytical chemistry, microbiology, statistics, manufacturing, and quality assurance). Project plans, along with the full support of senior management, are essential elements for success. • Throughout the product lifecycle, various studies can be initiated to discover, observe, correlate, or confirm information about the product and process. All studies should be planned and conducted according to sound scientific principles, appropriately documented, and approved in accordance with the established procedure appropriate for the stage of the lifecycle. • The terms attribute(s) (e.g., quality, product, component) and parameter(s) (e.g., process, operating, and equipment) are not categorized with respect to criticality in this guidance. With a lifecycle approach to process validation that employs risk based decision making throughout that lifecycle, the perception of criticality as a continuum rather than a binary state is more useful. All attributes and parameters should be evaluated in terms of their roles in the process and impact on the product or in-process material, and reevaluated as new information becomes available. The degree of control over those attributes or parameters should be commensurate with their risk to the process and process output. In other words, a higher degree of control is appropriate for attributes or parameters that pose a higher risk. The Agency recognizes that terminology usage can vary and expects that each manufacturer will communicate the meaning and intent of its terminology and categorization to the Agency. • Many products are single-source or involve complicated manufacturing processes. Homogeneity within a batch and consistency between batches are goals of process validation activities. Validation offers assurance that a process is reasonably protected against sources of variability that could affect production output, cause supply problems, and negatively affect public health. 11 This concept is discussed in more detail in FDA’s guidance for industry, Quality Systems Approach to Pharmaceutical Current Good Manufacturing Practice Regulations, available at http://www.fda.gov/Drugs/GuidanceComplianceRegulatoryInformation/Guidances/default.htm. [PAGE 11] Contains Nonbinding Recommendations B. Stage 1 ― Process Design Process design is the activity of defining the commercial manufacturing process that will be reflected in planned master production and control records. The goal of this stage is to design a process suitable for routine commercial manufacturing that can consistently deliver a product that meets its quality attributes. 1. Building and Capturing Process Knowledge and Understanding Generally, early process design experiments do not need to be performed under the CGMP conditions required for drugs intended for commercial distribution that are manufactured during Stage 2 (process qualification) and Stage 3 (continued process verification). They should, however, be conducted in accordance with sound scientific methods and principles, including good documentation practices. This recommendation is consistent with ICH Q10 Pharmaceutical Quality System.12 Decisions and justification of the controls should be sufficiently documented and internally reviewed to verify and preserve their value for use or adaptation later in the lifecycle of the process and product. Although often performed at small-scale laboratories, most viral inactivation and impurity clearance studies cannot be considered early process design experiments. Viral and impurity clearance studies intended to evaluate and estimate product quality at commercial scale should have a level of quality unit oversight that will ensure that the studies follow sound scientific methods and principles and the conclusions are supported by the data. Product development activities provide key inputs to the process design stage, such as the intended dosage form, the quality attributes, and a general manufacturing pathway. Process information available from product development activities can be leveraged in the process design stage. The functionality and limitations of commercial manufacturing equipment should be considered in the process design, as well as predicted contributions to variability posed by different component lots, production operators, environmental conditions, and measurement systems in the production setting. However, the full spectrum of input variability typical of commercial production is not generally known at this stage. Laboratory or pilot-scale models designed to be representative of the commercial process can be used to estimate variability. Designing an efficient process with an effective process control approach is dependent on the process knowledge and understanding obtained. Design of Experiment (DOE) studies can help develop process knowledge by revealing relationships, including multivariate interactions, between the variable inputs (e.g., component characteristics 13 or process parameters) and the resulting outputs (e.g., in-process material, intermediates, or the final product). Risk analysis tools can be used to screen potential variables for DOE studies to minimize the total number of experiments conducted while maximizing knowledge gained. The results of DOE studies can provide justification for establishing ranges of incoming component quality, equipment 12 Available at http://www.fda.gov/Drugs/GuidanceComplianceRegulatoryInformation/Guidances/default.htm. 13 “Component means any ingredient [raw material] intended for use in the manufacture of a drug product, including those that may not appear in such drug product” (§ 210.3(b)(3)). [PAGE 12] Contains Nonbinding Recommendations parameters, and in-process material quality attributes. FDA does not generally expect manufacturers to develop and test the process until it fails. Other activities, such as experiments or demonstrations at laboratory or pilot scale, also assist in evaluation of certain conditions and prediction of performance of the commercial process. These activities also provide information that can be used to model or simulate the commercial process. Computer-based or virtual simulations of certain unit operations or dynamics can provide process understanding and help avoid problems at commercial scale. It is important to understand the degree to which models represent the commercial process, including any differences that might exist, as this may have an impact on the relevance of information derived from the models. It is essential that activities and studies resulting in process understanding be documented. Documentation should reflect the basis for decisions made about the process. For example, manufacturers should document the variables studied for a unit operation and the rationale for those variables identified as significant. This information is useful during the process qualification and continued process verification stages, including when the design is revised or the strategy for control is refined or changed. 2. Establishing a Strategy for Process Control Process knowledge and understanding is the basis for establishing an approach to process control for each unit operation and the process overall. Strategies for process control can be designed to reduce input variation, adjust for input variation during manufacturing (and so reduce its impact on the output), or combine both approaches. Process controls address variability to assure quality of the product. Controls can consist of material analysis and equipment monitoring at significant processing points (§ 211.110(c)). Decisions regarding the type and extent of process controls can be aided by earlier risk assessments, then enhanced and improved as process experience is gained. FDA expects controls to include both examination of material quality and equipment monitoring. Special attention to control the process through operational limits and in-process monitoring is essential in two possible scenarios: 1. When the product attribute is not readily measurable due to limitations of sampling or detectability (e.g., viral clearance or microbial contamination) or 2. When intermediates and products cannot be highly characterized and well-defined quality attributes cannot be identified. These controls are established in the master production and control records (see § 211.186(a) and (b)(9)). More advanced strategies, which may involve the use of process analytical technology (PAT), can include timely analysis and control loops to adjust the processing conditions so that the output remains constant. Manufacturing systems of this type can provide a higher degree of [PAGE 13] Contains Nonbinding Recommendations process control than non-PAT systems. In the case of a strategy using PAT, the approach to process qualification will differ from that used in other process designs. Further information on PAT processes can be found in FDA’s guidance for industry on PAT ― A Framework for Innovative Pharmaceutical Development, Manufacturing, and Quality Assurance.14 The planned commercial production and control records, which contain the operational limits and overall strategy for process control, should be carried forward to the next stage for confirmation. C. Stage 2 ― Process Qualification During the process qualification (PQ) stage of process validation, the process design is evaluated to determine if it is capable of reproducible commercial manufacture. This stage has two elements: (1) design of the facility and qualification of the equipment and utilities and (2) process performance qualification (PPQ). During Stage 2, CGMP-compliant procedures must be followed. Successful completion of Stage 2 is necessary before commercial distribution.15 Products manufactured during this stage, if acceptable, can be released for distribution. 1. Design of a Facility and Qualification of Utilities and Equipment Proper design of a manufacturing facility is required under part 211, subpart C, of the CGMP regulations on Buildings and Facilities. It is essential that activities performed to assure proper facility design and commissioning precede PPQ. Here, the term qualification refers to activities undertaken to demonstrate that utilities and equipment are suitable for their intended use and perform properly. These activities necessarily precede manufacturing products at the commercial scale. Qualification of utilities and equipment generally includes the following activities: • Selecting utilities and equipment construction materials, operating principles, and performance characteristics based on whether they are appropriate for their specific uses. • Verifying that utility systems and equipment are built and installed in compliance with the design specifications (e.g., built as designed with proper materials, capacity, and functions, and properly connected and calibrated). • Verifying that utility systems and equipment operate in accordance with the process requirements in all anticipated operating ranges. This should include challenging the equipment or system functions while under load comparable to that expected during 14 Available at http://www.fda.gov/Drugs/GuidanceComplianceRegulatoryInformation/Guidances/default.htm. Other references that may be useful include ASTM E2474-06 “Standard Practice for Pharmaceutical Process Design Utilizing Process Analytical Technology” and ASTM E2476-09 “Standard Guide for Risk Assessment and Risk Control as it Impacts the Design, Development, and Operation of PAT Processes for Pharmaceutical Manufacture.” 15 As discussed in section III of this guidance, process validation (including process qualification) is legally enforceable under section 501(a)(2)(B) of the Act. FDA regulations require that process validation procedures be established and followed (§ 211.100) before a batch can be distributed (§§ 211.22 and 211.165). [PAGE 14] Contains Nonbinding Recommendations routine production. It should also include the performance of interventions, stoppage, and start-up as is expected during routine production. Operating ranges should be shown capable of being held as long as would be necessary during routine production. Qualification of utilities and equipment can be covered under individual plans or as part of an overall project plan. The plan should consider the requirements of use and can incorporate risk management to prioritize certain activities and to identify a level of effort in both the performance and documentation of qualification activities. The plan should identify the following items: 1. the studies or tests to use, 2. the criteria appropriate to assess outcomes, 3. the timing of qualification activities, 4. the responsibilities of relevant departments and the quality unit, and 5. the procedures for documenting and approving the qualification. The project plan should also include the firm’s requirements for the evaluation of changes. Qualification activities should be documented and summarized in a report with conclusions that address criteria in the plan. The quality control unit must review and approve the qualification plan and report (§ 211.22). 2. Process Performance Qualification The process performance qualification (PPQ) is the second element of Stage 2, process qualification. The PPQ combines the actual facility, utilities, equipment (each now qualified), and the trained personnel with the commercial manufacturing process, control procedures, and components to produce commercial batches. A successful PPQ will confirm the process design and demonstrate that the commercial manufacturing process performs as expected. Success at this stage signals an important milestone in the product lifecycle. A manufacturer must successfully complete PPQ before commencing commercial distribution of the drug product.16 The decision to begin commercial distribution should be supported by data from commercial-scale batches. Data from laboratory and pilot studies can provide additional assurance that the commercial manufacturing process performs as expected. The approach to PPQ should be based on sound science and the manufacturer’s overall level of product and process understanding and demonstrable control. The cumulative data from all relevant studies (e.g., designed experiments; laboratory, pilot, and commercial batches) should be used to establish the manufacturing conditions in the PPQ. To understand the commercial process sufficiently, the manufacturer will need to consider the effects of scale. However, it is not typically necessary to explore the entire operating range at commercial scale if assurance can be provided by process design data. Previous credible experience with sufficiently similar products and processes can also be helpful. In addition, we strongly recommend firms employ 16 See section III of this guidance, Statutory and Regulatory Requirements for Process Validation. [PAGE 15] Contains Nonbinding Recommendations objective measures (e.g., statistical metrics) wherever feasible and meaningful to achieve adequate assurance. In most cases, PPQ will have a higher level of sampling, additional testing, and greater scrutiny of process performance than would be typical of routine commercial production. The level of monitoring and testing should be sufficient to confirm uniform product quality throughout the batch. The increased level of scrutiny, testing, and sampling should continue through the process verification stage as appropriate, to establish levels and frequency of routine sampling and monitoring for the particular product and process. Considerations for the duration of the heightened sampling and monitoring period could include, but are not limited to, volume of production, process complexity, level of process understanding, and experience with similar products and processes. The extent to which some materials, such as column resins or molecular filtration media, can be re-used without adversely affecting product quality can be assessed in relevant laboratory studies. The usable lifetimes of such materials should be confirmed by an ongoing PPQ protocol during commercial manufacture. A manufacturing process that uses PAT may warrant a different PPQ approach. PAT processes are designed to measure in real time the attributes of an in-process material and then adjust the process in a timely control loop so the process maintains the desired quality of the output material. The process design stage and the process qualification stage should focus on the measurement system and control loop for the measured attribute. Regardless, the goal of validating any manufacturing process is the same: to establish scientific evidence that the process is reproducible and will consistently deliver quality products. 3. PPQ Protocol A written protocol that specifies the manufacturing conditions, controls, testing, and expected outcomes is essential for this stage of process validation. We recommend that the protocol discuss the following elements: • The manufacturing conditions, including operating parameters, processing limits, and component (raw material) inputs. • The data to be collected and when and how it will be evaluated. • Tests to be performed (in-process, release, characterization) and acceptance criteria for each significant processing step. • The sampling plan, including sampling points, number of samples, and the frequency of sampling for each unit operation and attribute. The number of samples should be adequate to provide sufficient statistical confidence of quality both within a batch and between batches. The confidence level selected can be based on risk analysis as it relates to the particular attribute under examination. Sampling during this stage should be more extensive than is typical during routine production. [PAGE 16] Contains Nonbinding Recommendations • Criteria and process performance indicators that allow for a science- and risk-based decision about the ability of the process to consistently produce quality products. The criteria should include: — A description of the statistical methods to be used in analyzing all collected data (e.g., statistical metrics defining both intra-batch and inter-batch variability). — Provision for addressing deviations from expected conditions and handling of nonconforming data. Data should not be excluded from further consideration in terms of PPQ without a documented, science-based justification.17 • Design of facilities and the qualification of utilities and equipment, personnel training and qualification, and verification of material sources (components and container/closures), if not previously accomplished. • Status of the validation of analytical methods used in measuring the process, in- process materials, and the product. • Review and approval of the protocol by appropriate departments and the quality unit. 4. PPQ Protocol Execution and Report Execution of the PPQ protocol should not begin until the protocol has been reviewed and approved by all appropriate departments, including the quality unit. Any departures from the protocol must be made according to established procedure or provisions in the protocol. Such departures must be justified and approved by all appropriate departments and the quality unit before implementation (§ 211.100). The commercial manufacturing process and routine procedures must be followed during PPQ protocol execution (§§ 211.100(b) and 211.110(a)). The PPQ lots should be manufactured under normal conditions by the personnel routinely expected to perform each step of each unit operation in the process. Normal operating conditions should include the utility systems (e.g., air handling and water purification), material, personnel, environment, and manufacturing procedures. A report documenting and assessing adherence to the written PPQ protocol should be prepared in a timely manner after the completion of the protocol. This report should: • Discuss and cross-reference all aspects of the protocol. • Summarize data collected and analyze the data, as specified by the protocol. 17 For additional guidance regarding out-of-specification results, see FDA’s Guidance for Industry, Investigating Out-of-Specification (OOS)Test Results for Pharmaceutical Production, available at http://www.fda.gov/downloads/Drugs/GuidanceComplianceRegulatoryInformation/Guidances/ucm070287.pdf. [PAGE 17] Contains Nonbinding Recommendations • Evaluate any unexpected observations and additional data not specified in the protocol. • Summarize and discuss all manufacturing nonconformances such as deviations, aberrant test results, or other information that has bearing on the validity of the process. • Describe in sufficient detail any corrective actions or changes that should be made to existing procedures and controls. • State a clear conclusion as to whether the data indicates the process met the conditions established in the protocol and whether the process is considered to be in a state of control. If not, the report should state what should be accomplished before such a conclusion can be reached. This conclusion should be based on a documented justification for the approval of the process, and release of lots produced by it to the market in consideration of the entire compilation of knowledge and information gained from the design stage through the process qualification stage. • Include all appropriate department and quality unit review and approvals. D. Stage 3 ― Continued Process Verification The goal of the third validation stage is continual assurance that the process remains in a state of control (the validated state) during commercial manufacture. A system or systems for detecting unplanned departures from the process as designed is essential to accomplish this goal. Adherence to the CGMP requirements, specifically, the collection and evaluation of information and data about the performance of the process, will allow detection of undesired process variability. Evaluating the performance of the process identifies problems and determines whether action must be taken to correct, anticipate, and prevent problems so that the process remains in control (§ 211.180(e)). An ongoing program to collect and analyze product and process data that relate to product quality must be established (§ 211.180(e)). The data collected should include relevant process trends and quality of incoming materials or components, in-process material, and finished products. The data should be statistically trended and reviewed by trained personnel. The information collected should verify that the quality attributes are being appropriately controlled throughout the process. We recommend that a statistician or person with adequate training in statistical process control techniques develop the data collection plan and statistical methods and procedures used in measuring and evaluating process stability and process capability.18 Procedures should describe 18 Some references that may be useful include the following: ASTM E2281-03 “Standard Practice for Process and Measurement Capability Indices,” ASTM E2500-07 “Standard Guide for Specification, Design, and Verification of Pharmaceutical and Biopharmaceutical Manufacturing Systems and Equipment,” and ASTM E2709-09 “Standard Practice for Demonstrating Capability to Comply with a Lot Acceptance Procedure.” This is not a complete list of all useful references on this topic. Many industry standards, books, and guides on these topics are available. [PAGE 18] Contains Nonbinding Recommendations how trending and calculations are to be performed and should guard against overreaction to individual events as well as against failure to detect unintended process variability. Production data should be collected to evaluate process stability and capability. The quality unit should review this information. If properly carried out, these efforts can identify variability in the process and/or signal potential process improvements. Good process design and development should anticipate significant sources of variability and establish appropriate detection, control, and/or mitigation strategies, as well as appropriate alert and action limits. However, a process is likely to encounter sources of variation that were not previously detected or to which the process was not previously exposed. Many tools and techniques, some statistical and others more qualitative, can be used to detect variation, characterize it, and determine the root cause. We recommend that the manufacturer use quantitative, statistical methods whenever appropriate and feasible. Scrutiny of intra-batch as well as inter-batch variation is part of a comprehensive continued process verification program under § 211.180(e). We recommend continued monitoring and sampling of process parameters and quality attributes at the level established during the process qualification stage until sufficient data are available to generate significant variability estimates. These estimates can provide the basis for establishing levels and frequency of routine sampling and monitoring for the particular product and process. Monitoring can then be adjusted to a statistically appropriate and representative level. Process variability should be periodically assessed and monitoring adjusted accordingly. Variation can also be detected by the timely assessment of defect complaints, out-of- specification findings, process deviation reports, process yield variations, batch records, incoming raw material records, and adverse event reports. Production line operators and quality unit staff should be encouraged to provide feedback on process performance. We recommend that the quality unit meet periodically with production staff to evaluate data, discuss possible trends or undesirable process variation, and coordinate any correction or follow-up actions by production. Data gathered during this stage might suggest ways to improve and/or optimize the process by altering some aspect of the process or product, such as the operating conditions (ranges and set- points), process controls, component, or in-process material characteristics. A description of the planned change, a well-justified rationale for the change, an implementation plan, and quality unit approval before implementation must be documented (§ 211.100). Depending on how the proposed change might affect product quality, additional process design and process qualification activities could be warranted.19 Maintenance of the facility, utilities, and equipment is another important aspect of ensuring that a process remains in control. Once established, qualification status must be maintained through routine monitoring, maintenance, and calibration procedures and schedules (21 CFR part 211, 19 Certain manufacturing changes may call for formal notification to the Agency before implementation, as directed by existing regulations (see, e.g., 21 CFR 314.70 and 601.12). [PAGE 19] Contains Nonbinding Recommendations subparts C and D). The equipment and facility qualification data should be assessed periodically to determine whether re-qualification should be performed and the extent of that re-qualification. Maintenance and calibration frequency should be adjusted based on feedback from these activities. V. CONCURRENT RELEASE OF PPQ BATCHES In most cases, the PPQ study needs to be completed successfully and a high degree of assurance in the process achieved before commercial distribution of a product. In special situations, the PPQ protocol can be designed to release a PPQ batch for distribution before complete execution of the protocol steps and activities, i.e., concurrent release. FDA expects that concurrent release will be used rarely. Concurrent release might be appropriate for processes used infrequently for various reasons, such as to manufacture drugs for which there is limited demand (e.g., orphan drugs, minor use and minor species veterinary drugs) or which have short half lives (e.g., radiopharmaceuticals, including positron emission tomography drugs). Concurrent release might also be appropriate for drugs that are medically necessary and are being manufactured in coordination with the Agency to alleviate a short supply. Conclusions about a commercial manufacturing process can only be made after the PPQ protocol is fully executed and the data are fully evaluated. If Stage 2 qualification is not successful (i.e., does not demonstrate that the process as designed is capable of reproducible performance at commercial scale), then additional design studies and qualification may be necessary. The new product and process understanding obtained from the unsuccessful qualification study(ies) can have negative implications if any lot was already distributed. Full execution of Stages 1 and 2 of process validation is intended to preclude or minimize that outcome. Circumstances and rationale for concurrent release should be fully described in the PPQ protocol. Even when process performance assessment based on the PPQ protocol is still outstanding, any lot released concurrently must comply with all CGMPs, regulatory approval requirements, and PPQ protocol lot release criteria. Lot release under a PPQ protocol is based upon meeting confidence levels appropriate for each quality attribute of the drug. When warranted and used, concurrent release should be accompanied by a system for careful oversight of the distributed batch to facilitate rapid customer feedback. For example, customer complaints and defect reports should be rapidly assessed to determine root cause and whether the process should be improved or changed. Concurrently released lots must also be assessed in light of any negative PPQ study finding or conclusions and appropriate corrective action must be taken (§§ 211.100(a), 211.180(e), and 211.192). We recommend that each batch in a concurrent release program be evaluated for inclusion in the stability program. It is important that stability test data be promptly evaluated to ensure rapid detection and correction of any problems. [PAGE 20] Contains Nonbinding Recommendations VI. DOCUMENTATION Documentation at each stage of the process validation lifecycle is essential for effective communication in complex, lengthy, and multidisciplinary projects. Documentation is important so that knowledge gained about a product and process is accessible and comprehensible to others involved in each stage of the lifecycle. Information transparency and accessibility are fundamental tenets of the scientific method. They are also essential to enabling organizational units responsible and accountable for the process to make informed, science-based decisions that ultimately support the release of a product to commerce. The degree and type of documentation required by CGMP vary during the validation lifecycle. Documentation requirements are greatest during Stage 2, process qualification, and Stage 3, continued process verification. Studies during these stages must conform to CGMPs and must be approved by the quality unit in accordance with the regulations (see §§ 211.22 and 211.100). Viral and impurity clearance studies, even when performed at small scale, also require quality unit oversight. CGMP documents for commercial manufacturing (i.e., the initial commercial master batch production and control record (§ 211.186) and supporting procedures) are key outputs of Stage 1, process design. We recommend that firms diagram the process flow for the full-scale process. Process flow diagrams should describe each unit operation, its placement in the overall process, monitoring and control points, and the component, as well as other processing material inputs (e.g., processing aids) and expected outputs (i.e., in-process materials and finished product). It is also useful to generate and preserve process flow diagrams of the various scales as the process design progresses to facilitate comparison and decision making about their comparability. VII. ANALYTICAL METHODOLOGY Process knowledge depends on accurate and precise measuring techniques used to test and examine the quality of drug components, in-process materials, and finished products. Validated analytical methods are not necessarily required during product- and process-development activities or when used in characterization studies. Nevertheless, analytical methods should be scientifically sound (e.g., specific, sensitive, and accurate) and provide results that are reliable. There should be assurance of proper equipment function for laboratory experiments. Procedures for analytical method and equipment maintenance, documentation practices, and calibration practices supporting process-development efforts should be documented or described. New analytical technology and modifications to existing technology are continually being developed and can be used to characterize the process or the product. Use of these methods is particularly appropriate when they reduce risk by providing greater understanding or control of product quality. However, analytical methods supporting commercial batch release must follow CGMPs in parts 210 and 211. Clinical supply production should follow the CGMPs appropriate for the particular phase of clinical studies. [PAGE 21] Contains Nonbinding Recommendations GLOSSARY Capability of a process: Ability of a process to produce a product that will fulfill the requirements of that product. The concept of process capability can also be defined in statistical terms. (ISO 9000:2005) Commercial manufacturing process: The manufacturing process resulting in commercial product (i.e., drug that is marketed, distributed, and sold or intended to be sold). For the purposes of this guidance, the term commercial manufacturing process does not include clinical trial or treatment IND material. Concurrent release: Releasing for distribution a lot of finished product, manufactured following a qualification protocol, that meets the lot release criteria established in the protocol, but before the entire study protocol has been executed. Continued process verification: Assuring that during routine production the process remains in a state of control. Performance indicators: Measurable values used to quantify quality objectives to reflect the performance of an organization, process or system, also known as performance metrics in some regions. (ICH Q10) Process design: Defining the commercial manufacturing process based on knowledge gained through development and scale-up activities. Process qualification: Confirming that the manufacturing process as designed is capable of reproducible commercial manufacturing. Process validation: The collection and evaluation of data, from the process design stage through commercial production, which establishes scientific evidence that a process is capable of consistently delivering quality products. Quality: The degree to which a set of inherent properties of a product, system, or process fulfils requirements. (ICH Q9) State of control: A condition in which the set of controls consistently provides assurance of continued process performance and product quality. (ICH Q10) [PAGE 22] Contains Nonbinding Recommendations REFERENCES FDA, (CBER), Validation of Procedures for Processing of Human Tissues Intended for Transplantation, guidance for industry, May 2002. FDA, (CDER), Investigating Out-of-Specification (OOS) Test Results for Pharmaceutical Production, guidance for industry, October 2006. FDA, (CDER, CVM, and ORA), PAT — A Framework for Innovative Pharmaceutical Development, Manufacturing, and Quality Assurance, guidance for industry, September 2004. FDA, (CDER, CBER, CVM, and ORA), Quality Systems Approach to Pharmaceutical Current Good Manufacturing Practice Regulations, guidance for industry, September 2006. FDA/Global Harmonization Task Force (GHTF; medical devices), Quality Management Systems – Process Validation, edition 2, guidance, January 2004. FDA/ICH, (CDER and CBER), Q7 Good Manufacturing Practice for Active Pharmaceutical Ingredients, guidance for industry, August 2001. FDA/ICH, (CDER and CBER), Q8(R2) Pharmaceutical Development, guidance for industry, November 2009. FDA/ICH, (CDER and CBER), Q9 Quality Risk Management, guidance for industry, June 2006. FDA/ICH (CDER and CBER) Q10 Pharmaceutical Quality System, guidance for industry, April 2009. ASTM E2474-06 Standard Practice for Pharmaceutical Process Design Utilizing Process Analytical Technology. ASTM E2476-09 Standard Guide for Risk Assessment and Risk Control as it Impacts the Design, Development, and Operation of PAT Processes for Pharmaceutical Manufacture. ASTM E2281-03 Standard Practice for Process and Measurement Capability Indices. ASTM E2500-07 Standard Guide for Specification, Design, and Verification of Pharmaceutical and Biopharmaceutical Manufacturing Systems and Equipment. ASTM E2709-10 Standard Practice for Demonstrating Capability to Comply with a Lot Acceptance Procedure. --- ### Document: ICH Q10 Complete (ICH) # ICH Q10 Pharmaceutical Quality System: Guideline for Pharmaceutical Quality System === PAGE 1 === INTERNATIONAL CONFERENCE ON HARMONISATION OF TECHNICAL REQUIREMENTS FOR REGISTRATION OF PHARMACEUTICALS FOR HUMAN USE ICH HARMONISED TRIPARTITE GUIDELINE PHARMACEUTICAL QUALITY SYSTEM Q10 Current Step 4 version dated 4 June 2008 This Guideline has been developed by the appropriate ICH Expert Working Group and has been subject to consultation by the regulatory parties, in accordance with the ICH Process. At Step 4 of the Process the final draft is recommended for adoption to the regulatory bodies of the European Union, Japan and USA. === PAGE 2 === Pharmaceutical Quality System Q10 Document History Code History Date Q10 Approval by the Steering Committee under Step 2 and release for public consultation. 9 May 2007 Current Step 4 version Q10 Approval by the Steering Committee under Step 4 and recommendation for adoption to the three ICH regulatory bodies. 4 June 2008 === PAGE 3 === i PHARMACEUTICAL QUALITY SYSTEM ICH Harmonised Tripartite Guideline Having reached Step 4 of the ICH Process at the ICH Steering Committee meeting on 4 June 2008, this guideline is recommended for adoption to the three regulatory parties to ICH TABLE OF CONTENTS 1. PHARMACEUTICAL QUALITY SYSTEM ........................................................ 1 1.1 Introduction ............................................................................................................. 1 1.2 Scope ........................................................................................................................ 1 ### 1.3 Relationship of ICH Q10 to Regional GMP Requirements, ISO Standards and ICH Q7 ..................................................................................................................... 2 1.4 Relationship of ICH Q10 to Regulatory Approaches .............................................. 2 1.5 ICH Q10 Objectives ................................................................................................. 2 1.5.1 Achieve Product Realisation ........................................................................ 2 1.5.2 Establish and Maintain a State of Control ................................................. 3 1.5.3 Facilitate Continual Improvement ............................................................... 3 1.6 Enablers: Knowledge Management and Quality Risk Management ..................... 3 1.6.1 Knowledge Management .............................................................................. 3 1.6.2 Quality Risk Management ........................................................................... 3 1.7 Design and Content Considerations ....................................................................... 3 1.8 Quality Manual ....................................................................................................... 4 2. MANAGEMENT RESPONSIBILITY .................................................................. 4 2.1 Management Commitment...................................................................................... 4 2.2 Quality Policy .......................................................................................................... 5 2.3 Quality Planning ..................................................................................................... 5 2.4 Resource Management ............................................................................................ 5 2.5 Internal Communication ......................................................................................... 6 2.6 Management Review ............................................................................................... 6 2.7 Management of Outsourced Activities and Purchased Materials .......................... 6 2.8 Management of Change in Product Ownership ...................................................... 6 === PAGE 4 === Pharmaceutical Quality System ii 3. CONTINUAL IMPROVEMENT OF PROCESS PERFORMANCE AND PRODUCT QUALITY ........................................................................................... 7 3.1 Lifecycle Stage Goals ............................................................................................... 7 3.1.1 Pharmaceutical Development....................................................................... 7 3.1.2 Technology Transfer ..................................................................................... 7 3.1.3 Commercial Manufacturing ......................................................................... 7 3.1.4 Product Discontinuation .............................................................................. 7 3.2 Pharmaceutical Quality System Elements ............................................................. 7 3.2.1 Process Performance and Product Quality Monitoring System .................. 8 3.2.2 Corrective Action and Preventive Action (CAPA) System ............................ 9 3.2.3 Change Management System ..................................................................... 10 3.2.4 Management Review of Process Performance and Product Quality ......... 11 4. CONTINUAL IMPROVEMENT OF THE PHARMACEUTICAL QUALITY SYSTEM ................................................................................................................ 11 4.1 Management Review of the Pharmaceutical Quality System .............................. 11 ### 4.2 Monitoring of Internal and External Factors Impacting the Pharmaceutical Quality System ...................................................................................................... 12 4.3 Outcomes of Management Review and Monitoring .............................................. 12 5. GLOSSARY .......................................................................................................... 13 Annex 1:Potential Opportunities to Enhance Science and Risk Based Regulatory Approaches ........................................................................................................... 16 Annex 2:Diagram of the ICH Q10 Pharmaceutical Quality System Model ...................... 17 === PAGE 5 === PHARMACEUTICAL QUALITY SYSTEM 1. PHARMACEUTICAL QUALITY SYSTEM ### 1.1 Introduction This document establishes a new ICH tripartite guideline describing a model for an effective quality management system for the pharmaceutical industry, referred to as the Pharmaceutical Quality System. Throughout this guideline, the term “pharmaceutical quality system” refers to the ICH Q10 model. ICH Q10 describes one comprehensive model for an effective pharmaceutical quality system that is based on International Standards Organisation (ISO) quality concepts, includes applicable Good Manufacturing Practice (GMP) regulations and complements ICH Q8 “Pharmaceutical Development” and ICH Q9 “Quality Risk Management”. ICH Q10 is a model for a pharmaceutical quality system that can be implemented throughout the different stages of a product lifecycle. Much of the content of ICH Q10 applicable to manufacturing sites is currently specified by regional GMP requirements. ICH Q10 is not intended to create any new expectations beyond current regulatory requirements. Consequently, the content of ICH Q10 that is additional to current regional GMP requirements is optional. ICH Q10 demonstrates industry and regulatory authorities’ support of an effective pharmaceutical quality system to enhance the quality and availability of medicines around the world in the interest of public health. Implementation of ICH Q10 throughout the product lifecycle should facilitate innovation and continual improvement and strengthen the link between pharmaceutical development and manufacturing activities. ### 1.2 Scope This guideline applies to the systems supporting the development and manufacture of pharmaceutical drug substances (i.e., API) and drug products, including biotechnology and biological products, throughout the product lifecycle. The elements of ICH Q10 should be applied in a manner that is appropriate and proportionate to each of the product lifecycle stages, recognising the differences among, and the different goals of each stage (see Section 3). For the purposes of this guideline, the product lifecycle includes the following technical activities for new and existing products: • Pharmaceutical Development: o Drug substance development; o Formulation development (including container/closure system); o Manufacture of investigational products; o Delivery system development (where relevant); o Manufacturing process development and scale-up; o Analytical method development. • Technology Transfer: o New product transfers during Development through Manufacturing; o Transfers within or between manufacturing and testing sites for marketed products. === PAGE 6 === Pharmaceutical Quality System • Commercial Manufacturing: o Acquisition and control of materials; o Provision of facilities, utilities, and equipment; o Production (including packaging and labelling); o Quality control and assurance; o Release; o Storage; o Distribution (excluding wholesaler activities). • Product Discontinuation: o Retention of documentation; o Sample retention; o Continued product assessment and reporting. ### 1.3 Relationship of ICH Q10 to Regional GMP Requirements, ISO Standards and ICH Q7 Regional GMP requirements, the ICH Q7 Guideline, “Good Manufacturing Practice Guide for Active Pharmaceutical Ingredients”, and ISO quality management system guidelines form the foundation for ICH Q10. To meet the objectives described below, ICH Q10 augments GMPs by describing specific quality system elements and management responsibilities. ICH Q10 provides a harmonised model for a pharmaceutical quality system throughout the lifecycle of a product and is intended to be used together with regional GMP requirements. The regional GMPs do not explicitly address all stages of the product lifecycle (e.g., Development). The quality system elements and management responsibilities described in this guideline are intended to encourage the use of science and risk based approaches at each lifecycle stage, thereby promoting continual improvement across the entire product lifecycle. ### 1.4 Relationship of ICH Q10 to Regulatory Approaches Regulatory approaches for a specific product or manufacturing facility should be commensurate with the level of product and process understanding, the results of quality risk management, and the effectiveness of the pharmaceutical quality system. When implemented, the effectiveness of the pharmaceutical quality system can normally be evaluated during a regulatory inspection at the manufacturing site. Potential opportunities to enhance science and risk based regulatory approaches are identified in Annex 1. Regulatory processes will be determined by region. ### 1.5 ICH Q10 Objectives Implementation of the Q10 model should result in achievement of three main objectives which complement or enhance regional GMP requirements. #### 1.5.1 Achieve Product Realisation To establish, implement and maintain a system that allows the delivery of products with the quality attributes appropriate to meet the needs of patients, health care professionals, regulatory authorities (including compliance with approved regulatory filings) and other internal and external customers. === PAGE 7 === Pharmaceutical Quality System #### 1.5.2 Establish and Maintain a State of Control To develop and use effective monitoring and control systems for process performance and product quality, thereby providing assurance of continued suitability and capability of processes. Quality risk management can be useful in identifying the monitoring and control systems. #### 1.5.3 Facilitate Continual Improvement To identify and implement appropriate product quality improvements, process improvements, variability reduction, innovations and pharmaceutical quality system enhancements, thereby increasing the ability to fulfil quality needs consistently. Quality risk management can be useful for identifying and prioritising areas for continual improvement. ### 1.6 Enablers: Knowledge Management and Quality Risk Management Use of knowledge management and quality risk management will enable a company to implement ICH Q10 effectively and successfully. These enablers will facilitate achievement of the objectives described in Section 1.5 above by providing the means for science and risk based decisions related to product quality. #### 1.6.1 Knowledge Management Product and process knowledge should be managed from development through the commercial life of the product up to and including product discontinuation. For example, development activities using scientific approaches provide knowledge for product and process understanding. Knowledge management is a systematic approach to acquiring, analysing, storing and disseminating information related to products, manufacturing processes and components. Sources of knowledge include, but are not limited to prior knowledge (public domain or internally documented); pharmaceutical development studies; technology transfer activities; process validation studies over the product lifecycle; manufacturing experience; innovation; continual improvement; and change management activities. #### 1.6.2 Quality Risk Management Quality risk management is integral to an effective pharmaceutical quality system. It can provide a proactive approach to identifying, scientifically evaluating and controlling potential risks to quality. It facilitates continual improvement of process performance and product quality throughout the product lifecycle. ICH Q9 provides principles and examples of tools for quality risk management that can be applied to different aspects of pharmaceutical quality. ### 1.7 Design and Content Considerations (a) The design, organisation and documentation of the pharmaceutical quality system should be well structured and clear to facilitate common understanding and consistent application. (b) The elements of ICH Q10 should be applied in a manner that is appropriate and proportionate to each of the product lifecycle stages, recognising the different goals and knowledge available for each stage. (c) The size and complexity of the company’s activities should be taken into consideration when developing a new pharmaceutical quality system or === PAGE 8 === Pharmaceutical Quality System modifying an existing one. The design of the pharmaceutical quality system should incorporate appropriate risk management principles. While some aspects of the pharmaceutical quality system can be company-wide and others site-specific, the effectiveness of the pharmaceutical quality system is normally demonstrated at the site level. (d) The pharmaceutical quality system should include appropriate processes, resources and responsibilities to provide assurance of the quality of outsourced activities and purchased materials as described in Section 2.7. (e) Management responsibilities, as described in Section 2, should be identified within the pharmaceutical quality system. (f) The pharmaceutical quality system should include the following elements, as described in Section 3: process performance and product quality monitoring, corrective and preventive action, change management and management review. (g) Performance indicators, as described in Section 4, should be identified and used to monitor the effectiveness of processes within the pharmaceutical quality system. ### 1.8 Quality Manual A Quality Manual or equivalent documentation approach should be established and should contain the description of the pharmaceutical quality system. The description should include: (a) The quality policy (see Section 2); (b) The scope of the pharmaceutical quality system; (c) Identification of the pharmaceutical quality system processes, as well as their sequences, linkages and interdependencies. Process maps and flow charts can be useful tools to facilitate depicting pharmaceutical quality system processes in a visual manner; (d) Management responsibilities within the pharmaceutical quality system (see Section 2). 2. MANAGEMENT RESPONSIBILITY Leadership is essential to establish and maintain a company-wide commitment to quality and for the performance of the pharmaceutical quality system. ### 2.1 Management Commitment (a) Senior management has the ultimate responsibility to ensure an effective pharmaceutical quality system is in place to achieve the quality objectives, and that roles, responsibilities, and authorities are defined, communicated and implemented throughout the company. (b) Management should: (1) Participate in the design, implementation, monitoring and maintenance of an effective pharmaceutical quality system; (2) Demonstrate strong and visible support for the pharmaceutical quality === PAGE 9 === Pharmaceutical Quality System system and ensure its implementation throughout their organisation; (3) Ensure a timely and effective communication and escalation process exists to raise quality issues to the appropriate levels of management; (4) Define individual and collective roles, responsibilities, authorities and inter-relationships of all organisational units related to the pharmaceutical quality system. Ensure these interactions are communicated and understood at all levels of the organisation. An independent quality unit/structure with authority to fulfil certain pharmaceutical quality system responsibilities is required by regional regulations; (5) Conduct management reviews of process performance and product quality and of the pharmaceutical quality system; (6) Advocate continual improvement; (7) Commit appropriate resources. ### 2.2 Quality Policy (a) Senior management should establish a quality policy that describes the overall intentions and direction of the company related to quality. (b) The quality policy should include an expectation to comply with applicable regulatory requirements and should facilitate continual improvement of the pharmaceutical quality system. (c) The quality policy should be communicated to and understood by personnel at all levels in the company. (d) The quality policy should be reviewed periodically for continuing effectiveness. ### 2.3 Quality Planning (a) Senior management should ensure the quality objectives needed to implement the quality policy are defined and communicated. (b) Quality objectives should be supported by all relevant levels of the company. (c) Quality objectives should align with the company’s strategies and be consistent with the quality policy. (d) Management should provide the appropriate resources and training to achieve the quality objectives. (e) Performance indicators that measure progress against quality objectives should be established, monitored, communicated regularly and acted upon as appropriate as described in Section 4.1 of this document. ### 2.4 Resource Management (a) Management should determine and provide adequate and appropriate resources (human, financial, materials, facilities and equipment) to implement and maintain the pharmaceutical quality system and continually improve its effectiveness. (b) Management should ensure that resources are appropriately applied to a === PAGE 10 === Pharmaceutical Quality System specific product, process or site. ### 2.5 Internal Communication (a) Management should ensure appropriate communication processes are established and implemented within the organisation. (b) Communications processes should ensure the flow of appropriate information between all levels of the company. (c) Communication processes should ensure the appropriate and timely escalation of certain product quality and pharmaceutical quality system issues. ### 2.6 Management Review (a) Senior management should be responsible for pharmaceutical quality system governance through management review to ensure its continuing suitability and effectiveness. (b) Management should assess the conclusions of periodic reviews of process performance and product quality and of the pharmaceutical quality system, as described in Sections 3 and 4. ### 2.7 Management of Outsourced Activities and Purchased Materials The pharmaceutical quality system, including the management responsibilities described in this section, extends to the control and review of any outsourced activities and quality of purchased materials. The pharmaceutical company is ultimately responsible to ensure processes are in place to assure the control of outsourced activities and quality of purchased materials. These processes should incorporate quality risk management and include: (a) Assessing prior to outsourcing operations or selecting material suppliers, the suitability and competence of the other party to carry out the activity or provide the material using a defined supply chain (e.g., audits, material evaluations, qualification); (b) Defining the responsibilities and communication processes for quality-related activities of the involved parties. For outsourced activities, this should be included in a written agreement between the contract giver and contract acceptor; (c) Monitoring and review of the performance of the contract acceptor or the quality of the material from the provider, and the identification and implementation of any needed improvements; (d) Monitoring incoming ingredients and materials to ensure they are from approved sources using the agreed supply chain. ### 2.8 Management of Change in Product Ownership When product ownership changes, (e.g., through acquisitions) management should consider the complexity of this and ensure: (a) The ongoing responsibilities are defined for each company involved; === PAGE 11 === Pharmaceutical Quality System (b) The necessary information is transferred. 3. CONTINUAL IMPROVEMENT OF PROCESS PERFORMANCE AND PRODUCT QUALITY This section describes the lifecycle stage goals and the four specific pharmaceutical quality system elements that augment regional requirements to achieve the ICH Q10 objectives, as defined in Section 1.5. It does not restate all regional GMP requirements. ### 3.1 Lifecycle Stage Goals The goals of each product lifecycle stage are described below. #### 3.1.1 Pharmaceutical Development The goal of pharmaceutical development activities is to design a product and its manufacturing process to consistently deliver the intended performance and meet the needs of patients and healthcare professionals, and regulatory authorities and internal customers’ requirements. Approaches to pharmaceutical development are described in ICH Q8. The results of exploratory and clinical development studies, while outside the scope of this guidance, are inputs to pharmaceutical development. #### 3.1.2 Technology Transfer The goal of technology transfer activities is to transfer product and process knowledge between development and manufacturing, and within or between manufacturing sites to achieve product realisation. This knowledge forms the basis for the manufacturing process, control strategy, process validation approach and ongoing continual improvement. #### 3.1.3 Commercial Manufacturing The goals of manufacturing activities include achieving product realisation, establishing and maintaining a state of control and facilitating continual improvement. The pharmaceutical quality system should assure that the desired product quality is routinely met, suitable process performance is achieved, the set of controls are appropriate, improvement opportunities are identified and evaluated, and the body of knowledge is continually expanded. #### 3.1.4 Product Discontinuation The goal of product discontinuation activities is to manage the terminal stage of the product lifecycle effectively. For product discontinuation, a pre-defined approach should be used to manage activities such as retention of documentation and samples and continued product assessment (e.g., complaint handling and stability) and reporting in accordance with regulatory requirements. ### 3.2 Pharmaceutical Quality System Elements The elements described below might be, required in part under regional GMP regulations. However, the Q10 model’s intent is to enhance these elements in order to promote the lifecycle approach to product quality. These four elements are: • Process performance and product quality monitoring system; • Corrective action and preventive action (CAPA) system; • Change management system; === PAGE 12 === Pharmaceutical Quality System • Management review of process performance and product quality. These elements should be applied in a manner that is appropriate and proportionate to each of the product lifecycle stages, recognising the differences among, and the different goals of, each stage. Throughout the product lifecycle, companies are encouraged to evaluate opportunities for innovative approaches to improve product quality. Each element is followed by a table of example applications of the element to the stages of the pharmaceutical lifecycle. #### 3.2.1 Process Performance and Product Quality Monitoring System Pharmaceutical companies should plan and execute a system for the monitoring of process performance and product quality to ensure a state of control is maintained. An effective monitoring system provides assurance of the continued capability of processes and controls to produce a product of desired quality and to identify areas for continual improvement. The process performance and product quality monitoring system should: (a) Use quality risk management to establish the control strategy. This can include parameters and attributes related to drug substance and drug product materials and components, facility and equipment operating conditions, in- process controls, finished product specifications, and the associated methods and frequency of monitoring and control. The control strategy should facilitate timely feedback / feedforward and appropriate corrective action and preventive action; (b) Provide the tools for measurement and analysis of parameters and attributes identified in the control strategy (e.g., data management and statistical tools); (c) Analyse parameters and attributes identified in the control strategy to verify continued operation within a state of control; (d) Identify sources of variation affecting process performance and product quality for potential continual improvement activities to reduce or control variation; (e) Include feedback on product quality from both internal and external sources, e.g., complaints, product rejections, non-conformances, recalls, deviations, audits and regulatory inspections and findings; (f) Provide knowledge to enhance process understanding, enrich the design space (where established), and enable innovative approaches to process validation. === PAGE 13 === Pharmaceutical Quality System Table I: Application of Process Performance and Product Quality Monitoring System throughout the Product Lifecycle Pharmaceutical Development Technology Transfer Commercial Manufacturing Product Discontinuation Process and product knowledge generated and process and product monitoring conducted throughout development can be used to establish a control strategy for manufacturing. Monitoring during scale-up activities can provide a preliminary indication of process performance and the successful integration into manufacturing. Knowledge obtained during transfer and scale up activities can be useful in further developing the control strategy. A well-defined system for process performance and product quality monitoring should be applied to assure performance within a state of control and to identify improvement areas. Once manufacturing ceases, monitoring such as stability testing should continue to completion of the studies. Appropriate action on marketed product should continue to be executed according to regional regulations. #### 3.2.2 Corrective Action and Preventive Action (CAPA) System The pharmaceutical company should have a system for implementing corrective actions and preventive actions resulting from the investigation of complaints, product rejections, non-conformances, recalls, deviations, audits, regulatory inspections and findings, and trends from process performance and product quality monitoring. A structured approach to the investigation process should be used with the objective of determining the root cause. The level of effort, formality, and documentation of the investigation should be commensurate with the level of risk, in line with ICH Q9. CAPA methodology should result in product and process improvements and enhanced product and process understanding. Table II: Application of Corrective Action and Preventive Action System throughout the Product Lifecycle Pharmaceutical Development Technology Transfer Commercial Manufacturing Product Discontinuation Product or process variability is explored. CAPA methodology is useful where corrective actions and preventive actions are incorporated into the iterative design and development process. CAPA can be used as an effective system for feedback, feedforward and continual improvement. CAPA should be used and the effectiveness of the actions should be evaluated. CAPA should continue after the product is discontinued. The impact on product remaining on the market should be considered as well as other products which might be impacted. === PAGE 14 === Pharmaceutical Quality System #### 3.2.3 Change Management System Innovation, continual improvement, the outputs of process performance and product quality monitoring and CAPA drive change. In order to evaluate, approve and implement these changes properly, a company should have an effective change management system. There is generally a difference in formality of change management processes prior to the initial regulatory submission and after submission, where changes to the regulatory filing might be required under regional requirements. The change management system ensures continual improvement is undertaken in a timely and effective manner. It should provide a high degree of assurance there are no unintended consequences of the change. The change management system should include the following, as appropriate for the stage of the lifecycle: (a) Quality risk management should be utilised to evaluate proposed changes. The level of effort and formality of the evaluation should be commensurate with the level of risk; (b) Proposed changes should be evaluated relative to the marketing authorisation, including design space, where established, and/or current product and process understanding. There should be an assessment to determine whether a change to the regulatory filing is required under regional requirements. As stated in ICH Q8, working within the design space is not considered a change (from a regulatory filing perspective). However, from a pharmaceutical quality system standpoint, all changes should be evaluated by a company’s change management system; (c) Proposed changes should be evaluated by expert teams contributing the appropriate expertise and knowledge from relevant areas (e.g., Pharmaceutical Development, Manufacturing, Quality, Regulatory Affairs and Medical), to ensure the change is technically justified. Prospective evaluation criteria for a proposed change should be set; (d) After implementation, an evaluation of the change should be undertaken to confirm the change objectives were achieved and that there was no deleterious impact on product quality. Table III: Application of Change Management System throughout the Product Lifecycle Pharmaceutical Development Technology Transfer Commercial Manufacturing Product Discontinuation Change is an inherent part of the development process and should be documented; the formality of the change management process should be consistent with the stage of pharmaceutical development. The change management system should provide management and documentation of adjustments made to the process during technology transfer activities. A formal change management system should be in place for commercial manufacturing. Oversight by the quality unit should provide assurance of appropriate science and risk based assessments. Any changes after product discontinuation should go through an appropriate change management system. === PAGE 15 === Pharmaceutical Quality System #### 3.2.4 Management Review of Process Performance and Product Quality Management review should provide assurance that process performance and product quality are managed over the lifecycle. Depending on the size and complexity of the company, management review can be a series of reviews at various levels of management and should include a timely and effective communication and escalation process to raise appropriate quality issues to senior levels of management for review. (a) The management review system should include: (1) The results of regulatory inspections and findings, audits and other assessments, and commitments made to regulatory authorities; (2) Periodic quality reviews, that can include: (i) Measures of customer satisfaction such as product quality complaints and recalls; (ii) Conclusions of process performance and product quality monitoring; (iii)The effectiveness of process and product changes including those arising from corrective action and preventive actions. (3) Any follow-up actions from previous management reviews. (b) The management review system should identify appropriate actions, such as: (1) Improvements to manufacturing processes and products; (2) Provision, training and/or realignment of resources; (3) Capture and dissemination of knowledge. Table IV: Application of Management Review of Process Performance and Product Quality throughout the Product Lifecycle Pharmaceutical Development Technology Transfer Commercial Manufacturing Product Discontinuation Aspects of management review can be performed to ensure adequacy of the product and process design. Aspects of management review should be performed to ensure the developed product and process can be manufactured at commercial scale. Management review should be a structured system, as described above, and should support continual improvement. Management review should include such items as product stability and product quality complaints. 4. CONTINUAL IMPROVEMENT OF THE PHARMACEUTICAL QUALITY SYSTEM This section describes activities that should be conducted to manage and continually improve the pharmaceutical quality system. ### 4.1 Management Review of the Pharmaceutical Quality System Management should have a formal process for reviewing the pharmaceutical quality system on a periodic basis. The review should include: (a) Measurement of achievement of pharmaceutical quality system objectives; (b) Assessment of performance indicators that can be used to monitor the === PAGE 16 === Pharmaceutical Quality System effectiveness of processes within the pharmaceutical quality system, such as: (1) Complaint, deviation, CAPA and change management processes; (2) Feedback on outsourced activities; (3) Self-assessment processes including risk assessments, trending, and audits; (4) External assessments such as regulatory inspections and findings and customer audits. ### 4.2 Monitoring of Internal and External Factors Impacting the Pharmaceutical Quality System Factors monitored by management can include: (a) Emerging regulations, guidance and quality issues that can impact the Pharmaceutical Quality System; (b) Innovations that might enhance the pharmaceutical quality system; (c) Changes in business environment and objectives; (d) Changes in product ownership. ### 4.3 Outcomes of Management Review and Monitoring The outcome of management review of the pharmaceutical quality system and monitoring of internal and external factors can include: (e) Improvements to the pharmaceutical quality system and related processes; (f) Allocation or reallocation of resources and/or personnel training; (g) Revisions to quality policy and quality objectives; (h) Documentation and timely and effective communication of the results of the management review and actions, including escalation of appropriate issues to senior management. === PAGE 17 === Pharmaceutical Quality System 5. GLOSSARY ICH and ISO definitions are used in ICH Q10 where they exist. For the purpose of ICH Q10, where the words “requirement”, “requirements” or “necessary” appear in an ISO definition, they do not necessarily reflect a regulatory requirement. The source of the definition is identified in parentheses after the definition. Where no appropriate ICH or ISO definition was available, an ICH Q10 definition was developed. Capability of a Process: Ability of a process to realise a product that will fulfil the requirements of that product. The concept of process capability can also be defined in statistical terms. (ISO 9000:2005) Change Management: A systematic approach to proposing, evaluating, approving, implementing and reviewing changes. (ICH Q10) Continual Improvement: Recurring activity to increase the ability to fulfil requirements. (ISO 9000:2005) Control Strategy: A planned set of controls, derived from current product and process understanding, that assures process performance and product quality. The controls can include parameters and attributes related to drug substance and drug product materials and components, facility and equipment operating conditions, in-process controls, finished product specifications, and the associated methods and frequency of monitoring and control. (ICH Q10) Corrective Action: Action to eliminate the cause of a detected non-conformity or other undesirable situation. NOTE: Corrective action is taken to prevent recurrence whereas preventive action is taken to prevent occurrence. (ISO 9000:2005) Design Space: The multidimensional combination and interaction of input variables (e.g., material attributes) and process parameters that have been demonstrated to provide assurance of quality. (ICH Q8) Enabler: A tool or process which provides the means to achieve an objective. (ICH Q10) Feedback / Feedforward: Feedback: The modification or control of a process or system by its results or effects. Feedforward: The modification or control of a process using its anticipated results or effects. (Oxford Dictionary of English. Oxford University Press; 2003) Feedback/ feedforward can be applied technically in process control strategies and conceptually in quality management. (ICH Q10) Innovation: The introduction of new technologies or methodologies. (ICH Q10) === PAGE 18 === Pharmaceutical Quality System Knowledge Management: Systematic approach to acquiring, analysing, storing, and disseminating information related to products, manufacturing processes and components. (ICH Q10) Outsourced Activities: Activities conducted by a contract acceptor under a written agreement with a contract giver. (ICH Q10) Performance Indicators: Measurable values used to quantify quality objectives to reflect the performance of an organisation, process or system, also known as “performance metrics” in some regions. (ICH Q10) Pharmaceutical Quality System (PQS): Management system to direct and control a pharmaceutical company with regard to quality. (ICH Q10 based upon ISO 9000:2005) Preventive Action: Action to eliminate the cause of a potential non-conformity or other undesirable potential situation. NOTE: Preventive action is taken to prevent occurrence whereas corrective action is taken to prevent recurrence. (ISO 9000:2005) Product Realisation: Achievement of a product with the quality attributes appropriate to meet the needs of patients, health care professionals, and regulatory authorities (including compliance with marketing authorisation) and internal customers requirements. (ICH Q10) Quality: The degree to which a set of inherent properties of a product, system or process fulfils requirements. (ICH Q9) Quality Manual: Document specifying the quality management system of an organisation. (ISO 9000:2005) Quality Objectives: A means to translate the quality policy and strategies into measurable activities. (ICH Q10) Quality Planning: Part of quality management focused on setting quality objectives and specifying necessary operational processes and related resources to fulfil the quality objectives. (ISO 9000:2005) Quality Policy: Overall intentions and direction of an organisation related to quality as formally expressed by senior management. (ISO 9000:2005) Quality Risk Management: A systematic process for the assessment, control, communication and review of risks to the quality of the drug (medicinal) product across the product lifecycle. (ICH Q9) === PAGE 19 === Pharmaceutical Quality System Senior Management: Person(s) who direct and control a company or site at the highest levels with the authority and responsibility to mobilise resources within the company or site. (ICH Q10 based in part on ISO 9000:2005) State of Control: A condition in which the set of controls consistently provides assurance of continued process performance and product quality. (ICH Q10) === PAGE 20 === Pharmaceutical Quality System Annex 1 Potential Opportunities to Enhance Science and Risk Based Regulatory Approaches * *Note: This annex reflects potential opportunities to enhance regulatory approaches. The actual regulatory process will be determined by region. Scenario Potential Opportunity 1. Comply with GMPs Compliance – status quo 2. Demonstrate effective pharmaceutical quality system, including effective use of quality risk management principles (e.g., ICH Q9 and ICH Q10). Opportunity to: • increase use of risk based approaches for regulatory inspections. 3. Demonstrate product and process understanding, including effective use of quality risk management principles (e.g., ICH Q8 and ICH Q9). Opportunity to: • facilitate science based pharmaceutical quality assessment; • enable innovative approaches to process validation; • establish real-time release mechanisms. 4. Demonstrate effective pharmaceutical quality system and product and process understanding, including the use of quality risk management principles (e.g., ICH Q8, ICH Q9 and ICH Q10). Opportunity to: • increase use of risk based approaches for regulatory inspections; • facilitate science based pharmaceutical quality assessment; • optimise science and risk based post-approval change processes to maximise benefits from innovation and continual improvement; • enable innovative approaches to process validation; • establish real-time release mechanisms. === PAGE 21 === Pharmaceutical Quality System Annex 2 Diagram of the ICH Q10 Pharmaceutical Quality System Model This diagram illustrates the major features of the ICH Q10 Pharmaceutical Quality System (PQS) model. The PQS covers the entire lifecycle of a product including pharmaceutical development, technology transfer, commercial manufacturing, and product discontinuation as illustrated by the upper portion of the diagram. The PQS augments regional GMPs as illustrated in the diagram. The diagram also illustrates that regional GMPs apply to the manufacture of investigational products. The next horizontal bar illustrates the importance of management responsibilities explained in Section 2 to all stages of the product lifecycle. The following horizontal bar lists the PQS elements which serve as the major pillars under the PQS model. These elements should be applied appropriately and proportionally to each lifecycle stage recognising opportunities to identify areas for continual improvement. The bottom set of horizontal bars illustrates the enablers: knowledge management and quality risk management, which are applicable throughout the lifecycle stages. These enablers support the PQS goals of achieving product realisation, establishing and maintaining a state of control, and facilitating continual improvement. --- ### Document: ICH Q12 Complete (ICH) # ICH Harmonised Guideline Q12 (2019): Technical and Regulatory Considerations for Pharmaceutical Product Lifecycle Management ## 1.0 INTERNATIONAL COUNCIL FOR HARMONISATION OF TECHNICAL REQUIREMENTS FOR PHARMACEUTICALS FOR HUMAN USE ICH HARMONISED GUIDELINE TECHNICAL AND REGULATORY CONSIDERATIONS FOR PHARMACEUTICAL PRODUCT LIFECYCLE MANAGEMENT Q12 Final version Adopted on 20 November 2019 This Guideline has been developed by the appropriate ICH Expert Working Group and has been subject to consultation by the regulatory parties, in accordance with the ICH Process. At Step 4 of the Process the final draft is recommended for adoption to the regulatory bodies of ICH regions. ICH Q12 Guideline Q12 Document History Code History Date Q12 Adopted by the Regulatory Members of the ICH Assembly under Step 4 (document dated 19 November 2019). 20 November 2019 Q12 Endorsement by the ICH Assembly under Step 2 and release for public consultation. 16 November 2017 Legal notice: This document is protected by copyright and may, with the exception of the ICH logo, be used, reproduced, incorporated into other works, adapted, modified, translated or distributed under a public license provided that ICH's copyright in the document is acknowledged at all times. In case of any adaption, modification or translation of the document, reasonable steps must be taken to clearly label, demarcate or otherwise identify that changes were made to or based on the original document. Any impression that the adaption, modification or translation of the original document is endorsed or sponsored by the ICH must be avoided. The document is provided "as is" without warranty of any kind. In no event shall the ICH or the authors of the original document be liable for any claim, damages or other liability arising from the use of the document. The above-mentioned permissions do not apply to content supplied by third parties. Therefore, for documents where the copyright vests in a third party, permission for reproduction must be obtained from this copyright holder. ICH Q12 Guideline ICH Q12 Guideline ICH HARMONISED GUIDELINE TECHNICAL AND REGULATORY CONSIDERATIONS FOR PHARMACEUTICAL PRODUCT LIFECYCLE MANAGEMENT Q12 ICH Consensus Guideline TABLE OF CONTENTS INTRODUCTION ............................................................................................................ 6 1.1 Objectives ............................................................................................................ 6 1.2 Scope ................................................................................................................... 7 1.3 ICH Q12 Regulatory Tools and Enablers ............................................................ 7 CATEGORISATION OF POST-APPROVAL CMC CHANGES .................................. 9 ESTABLISHED CONDITIONS (ECS) ......................................................................... 10 3.1 Introduction ....................................................................................................... 10 3.2 ECs in the Regulatory Submission .................................................................... 10 3.2.1 ECs Definition .................................................................................. 10 3.2.2 ECs in a Regulatory Dossier ............................................................. 10 3.2.3 Identification of ECs ......................................................................... 11 ##### 3.2.3.1 Identification of ECs for the Manufacturing Processes 11 3.2.3.2 Identification of ECs for Analytical Procedures ........... 13 3.2.4 Revision of ECs ................................................................................ 14 3.3 Roles and Responsibilities ................................................................................. 14 POST-APPROVAL CHANGE MANAGEMENT PROTOCOL (PACMP) ................. 15 4.1 Definition of a PACMP ..................................................................................... 15 4.2 Application of a PACMP ................................................................................... 15 4.3 Elements of a PACMP ....................................................................................... 16 4.4 Modification to an Approved PACMP .............................................................. 17 4.5 Types of PACMPs ............................................................................................. 17 PRODUCT LIFECYCLE MANAGEMENT (PLCM) DOCUMENT ........................... 18 5.1 PLCM Document: Scope .................................................................................. 18 5.2 Submitting the PLCM Document ...................................................................... 18 5.3 Maintenance of the PLCM Document ............................................................... 18 5.4 Format and Location of PLCM Document ........................................................ 18 PHARMACEUTICAL QUALITY SYSTEM (PQS) AND CHANGE MANAGEMENT ........................................................................................................... 19 6.1 PQS General Considerations ............................................................................. 19 6.2 Change Management Across the Supply Chain and Product Lifecycle ............ 20 RELATIONSHIP BETWEEN REGULATORY ASSESSMENT AND INSPECTION 20 STRUCTURED APPROACHES FOR FREQUENT CMC POST-APPROVAL CHANGES ..................................................................................................................... 21 ICH Q12 Guideline STABILITY DATA APPROACHES TO SUPPORT THE EVALUATION OF CMC CHANGES ..................................................................................................................... 21 10 GLOSSARY ................................................................................................................... 22 11 REFERENCES ............................................................................................................... 23 APPENDIX 1: CTD SECTIONS THAT CONTAIN ECS ................................................... 24 APPENDIX 2: PRINCIPLES OF CHANGE MANAGEMENT .......................................... 30 ICH Q12 Guideline INTRODUCTION ### 1.1 Objectives This guideline provides a framework to facilitate the management of post-approval CMC changes in a more predictable and efficient manner. A harmonised approach regarding technical and regulatory considerations for lifecycle management will benefit patients, industry, and regulatory authorities by promoting innovation and continual improvement in the pharmaceutical sector, strengthening quality assurance and improving supply of medicinal products. The concepts outlined in prior ICH Quality Guidelines (ICH Q8(R2), Q9, Q10 and Q11) provide opportunities for science- and risk-based approaches for use in drug development and regulatory decisions. These guidelines are valuable in the assessment of Chemistry, Manufacturing and Controls (CMC) changes across the product lifecycle. ICH Q8(R2) and Q11 guidelines focus mostly on early stage aspects of the product lifecycle (i.e., product development, registration and launch). This guideline addresses the commercial phase of the product lifecycle (as described in ICH Q10); and it both complements and adds to the flexible regulatory approaches to post-approval CMC changes described in ICH Q8(R2) and Q10 Annex 1. This guideline is also intended to demonstrate how increased product and process knowledge can contribute to a more precise and accurate understanding of which post- approval changes require a regulatory submission as well as the definition of the level of reporting categories for such changes (i.e., a better understanding of risk to product quality). Increased knowledge and effective implementation of the tools and enablers described in this guideline should enhance industry’s ability to manage many CMC changes effectively under the company’s Pharmaceutical Quality System (PQS) with less need for extensive regulatory oversight prior to implementation. This approach can incentivize continual improvement by providing an opportunity for greater flexibility in making post-approval changes. It could also result in fewer associated post-approval submissions to the Marketing Authorisation Application (MAA), and less associated regulatory burden. The extent of this operational and regulatory flexibility and its adequate implementation is subject to the regulatory framework in place, as well as product and process understanding (ICH Q8(R2) and Q11), application of quality risk management principles (ICH Q9), and an effective pharmaceutical quality system (ICH Q10). Regulatory Members of ICH are encouraged to provide publicly available information, preferably on their website, about the implementation of ICH Q12 in their region, especially with regard to regulatory considerations. ICH Q12 Guideline ### 1.2 Scope This guideline applies to pharmaceutical drug substances1 and products (both chemical and biological) that require a marketing authorization; and to drug-device combination products that meet the definition of a pharmaceutical or biological product. Changes needed to comply with new or revised pharmacopoeial monographs are not within the scope of this guideline. ### 1.3 ICH Q12 Regulatory Tools and Enablers Use of the following harmonised regulatory tools and enablers with associated guiding principles, as described in this guideline, will enhance the management of post-approval changes, and transparency between industry and regulatory authorities, supporting innovation and continual improvement. • Categorisation of Post-Approval CMC Changes (Chapter 2) Categorisation of Post-Approval CMC Changes describes a framework that encompasses a risk-based categorisation for the type of communication expected of the Marketing Authorisation Holder (MAH) with the regulatory authority regarding CMC changes. • Established Conditions (ECs) (Chapter 3) The concept of ECs provides a clear understanding between the MAH and regulatory authorities regarding the elements to assure product quality and that involve a regulatory communication, if changed. This guideline describes how ECs are identified as well as what information can be designated as supportive information that would not involve a regulatory communication, if changed. In addition, guidance is included for managing revisions of the ECs. • Post-Approval Change Management Protocol (PACMP) (Chapter 4) The PACMP is a regulatory tool that provides predictability regarding the information required to support a CMC change and the type of regulatory submission based on prior agreement between the MAH and regulatory authority. Such a mechanism enables planning and implementation of future changes to ECs in an efficient and predictable manner. • Product Lifecycle Management (PLCM) Document (Chapter 5) The PLCM document serves as a central repository for the ECs and the associated reporting category for changes made to ECs. The document also captures how a product will be managed during the commercial phase of the lifecycle including relevant post-approval CMC commitments and PACMPs. 1 For drug substance information incorporated by reference (e.g., a Master File) in an MAA, the holder of the referenced information may use Q12 tools where applicable. Use of Q12 tools is not intended to change the responsibilities for the holder of the referenced information, the MAH or the regulatory authority. For example, the holder of the referenced information has a responsibility to report relevant drug substance changes to the MAH referencing their submission, so that the MAH can assess the impact of the change and report any related changes to the approved MAA, as necessary and per regional requirements. ICH Q12 Guideline • Pharmaceutical Quality System (PQS) and Change Management (Chapter 6) An effective PQS as described in ICH Q10 and compliance with regional GMPs are necessary to gain full benefit from this guideline. In particular, management of manufacturing changes across the supply chain is an essential part of an effective change management system. This guideline provides recommendations for robust change management across single or multiple entities involved in the manufacture of a pharmaceutical product. • Relationship Between Regulatory Assessment and Inspection (Chapter 7) This guideline outlines the complementary roles of regulatory assessment and inspection in the oversight of post-approval changes; and how communication between assessors and inspectors facilitates the use of the tools included herein. • Structured Approaches for Frequent CMC Post-Approval Changes (Chapter 8) In addition to the other tools described above, this guideline describes a strategy for a structured approach applicable to frequent CMC changes, and a discussion of data expectations, to enable the use of immediate or other post- implementation notification. • Stability Data Approaches to Support the Evaluation of CMC Changes (Chapter 9) This guideline provides additional science- and risk-based approaches that are relevant to strategies for confirmatory stability studies to enable more timely implementation of CMC changes. Tools and enablers described above are complementary and are intended to link different phases of the product lifecycle. Pharmaceutical development activities result in an appropriate control strategy, elements of which are considered to be Established Conditions. All CMC changes to an approved product are managed through a company’s Pharmaceutical Quality System; changes to ECs must also be reported to the regulatory authority. Where the regulatory system provides for Categorisation of Post-approval CMC Changes for reporting according to risk, the MAH may propose reporting categories for changes to ECs based on risk and knowledge gained through enhanced pharmaceutical development. A system with risk-based reporting categories also facilitates the use of Post-Approval Change Management Protocols, which provide predictability regarding planning for future changes to ECs. The Product Lifecycle Management Document is a summary that transparently conveys to the regulatory authority how the MAH plans to manage post-approval CMC changes. The tools and enablers in this guideline do not change the Relationship Between Regulatory Assessment and Inspection; however, collaboration and communication between assessors and inspectors are necessary for the implementation of this guideline by regulators. This guideline provides Structured Approaches for Frequent CMC Post-Approval Changes to enable the implementation of certain CMC changes for authorised products without the need for prior regulatory review and approval. Finally, this guideline provides Stability Data Approaches to Support the Evaluation of CMC Changes; i.e., where the stability study is undertaken to confirm previously approved storage conditions and shelf-life. ICH Q12 Guideline CATEGORISATION OF POST-APPROVAL CMC CHANGES Regulatory mechanisms that allow the timely and efficient introduction of CMC changes are important for drug quality, safety, and availability. There is a range of potential CMC changes for which communication between a company and the regulatory authority is required. CMC changes vary from low to high potential risk with respect to product quality, safety, and efficacy. A well-characterised, risk-based categorisation of regulatory communication requirements is important to the efficient use of industry and regulatory resources. In such a regulatory system, the types of CMC changes that occur during the commercial phase of the pharmaceutical product lifecycle that invoke communication with regulatory authorities are classified with regard to the potential to have an adverse effect on product quality of the drug product. The regulatory communication category, supporting information/documentation requirements, and associated time frame for evaluation are commensurate with that potential risk. Based on potential risk, an inspection may be needed. Regulatory authorities are encouraged to utilise a system that incorporates risk-based regulatory processes for (a) requesting prior approval from the regulatory authority, (b) notifying the regulatory authority, or (c) simply recording CMC changes, with associated information requirements and, where applicable, timeframes for decision. Such a system would include the following categories for regulatory communications with one or more levels in each case: • Prior approval: Certain changes are considered to have sufficient risk to require regulatory authority review and approval prior to implementation and are requested by the MAH in a suitably detailed regulatory submission. • Notification: Certain moderate- to low-risk changes are judged to not require prior approval and generally require less information to support the change. These changes are communicated to the regulatory authority as a formal notification that takes place within a defined period of time before or after implementation, according to regional requirements. A mechanism for immediate notification is useful when prior approval is not required, but timely awareness of the change by the regulator is considered necessary. In addition, the changes that are not required to be reported to regulators are only managed and documented within the PQS, but may be verified during routine or other inspection. Harmonisation or convergence toward a system of risk-based categorisation of post- approval changes is encouraged as an important step toward achieving the objectives of this guideline. Such a system provides inherent, valuable flexibility in regulatory approach and a framework that can support additional regulatory opportunities such as: - Facilitating the use of tools and enablers described in this guideline by providing a range of request and notification categories available as a target for a lowering of regulatory submission requirements. - The use of a lower category for request/notification if certain criteria/conditions are met and the relevant supporting documentation is provided as described in ICH Q12 Guideline regional regulatory guidance; the need for regulatory inspection associated with the change may preclude the ability to use a lower category. - Providing options for converging to the same or similar reporting category as that in other jurisdictions. A risk-based categorisation system may be accomplished by having the principles captured in regulations with further details in guidance, which can provide additional flexibility to modify expectations as science and technology evolve. For examples of risk-based categorisation systems, refer to existing regulations and guidance of ICH members, and WHO guidelines and guidance on changes to authorised products. ESTABLISHED CONDITIONS (ECS) ### 3.1 Introduction This guideline establishes a harmonised approach to defining which elements in an application are considered necessary to assure product quality and therefore would require a regulatory submission if changed post-approval. These elements are being defined in this guideline as “Established Conditions for Manufacturing and Control” (referred to as ECs throughout this guideline). ### 3.2 ECs in the Regulatory Submission #### 3.2.1 ECs Definition ECs are legally binding information considered necessary to assure product quality. As a consequence, any change to ECs necessitates a submission to the regulatory authority. #### 3.2.2 ECs in a Regulatory Dossier This chapter describes scientific risk-based approaches which can be used when defining ECs and their reporting categories. Regional legal frameworks, supplemented through regulation and guidance, may define ECs with their reporting categories and/or may allow the scientific risk-based approaches described in this chapter to be considered. All regulatory dossiers contain a combination of ECs and supportive information. Supportive information is not considered to be ECs but is provided to share with regulators the development and manufacturing information at an appropriate level of detail. Knowledge gained throughout the product lifecycle (including pharmaceutical development and characterisation of chemical and biological drug substance and drug product) is the basis for identifying the elements of CMC that are ECs and those elements which are supportive information. An MAH should clearly identify the elements of CMC which they consider to be an EC and those which they consider to be supportive information. The rationales for the ECs are provided in the appropriate CTD modules. Similarly, the rationales for the associated reporting categories for changes to the ECs should be provided in the appropriate CTD modules. The regulator assesses the ECs with respect to established scientific guidelines. Where appropriate, regulators approve the EC and associated reporting category in line with the principles outlined in Chapter 2. ICH Q12 Guideline See Appendix 1 for more information regarding sections of the dossier that contain ECs and supportive information. Unless otherwise specified by regulatory requirement identifying ECs for a given product is not mandatory. ECs should not be confused with CMC regulatory commitments (e.g., stability, post- approval CMC commitment and other commitments) made by a MAH to provide data or information to the regulatory agency in a MAA. Such information, in the context of this guideline, is considered supportive information. Changes to CMC regulatory commitments are managed according to existing regional regulations and guidance. #### 3.2.3 Identification of ECs This chapter outlines approaches to define ECs for manufacturing processes and analytical procedures. A similar approach can be used to define other types of ECs (e.g., performance of the container closure system, device elements of drug-device combination products) and should be justified by the applicant and approved by the regulatory agency. The extent of ECs may vary based on the company’s development approach, product and process understanding, and the potential risk to product quality. Appropriate justification should be provided in support of the identification of ECs, the proposed reporting categories for ECs, and those aspects that are not ECs. ##### 3.2.3.1 Identification of ECs for the Manufacturing Processes A control strategy is designed to ensure that a product of required quality will be produced consistently (ICH Q8(R2)). It is a planned set of controls, derived from current product and process understanding, that assures process performance and product quality. The controls can include parameters and attributes related to drug substance and drug product materials and components, facility and equipment operating conditions, in-process controls, finished product specifications, and the associated methods and frequency of monitoring and control (ICH Q10). The ECs for a manufacturing process should be defined, based on product and process understanding, taking into account all the relevant elements of the control strategy. In addition to the unit operation and the sequence of steps, and in considering the overall control strategy, ECs proposed and justified in a manufacturing process description should be those inputs (e.g., process parameters, material attributes) and outputs (that may include in-process controls) that are necessary to assure product quality. Process parameters that need to be controlled to ensure that a product of required quality will be produced should be considered ECs. These ECs are identified through an initial risk assessment and application of knowledge gained from executed studies, prior knowledge, and a criticality assessment that determines the level of impact that a process parameter could have on product quality. The criticality assessment should account for severity of harm and whether the ranges studied sufficiently account for the expected variability in the EC. CPPs and other process parameters where an impact on product quality cannot be reasonably excluded should be identified as ECs. Once ECs are identified, an updated assessment of the potential risk to product quality associated with changing the EC, taking into account the overall control strategy informs the reporting category for the EC. The assessment of potential risk is derived from risk management activities as described in ICH Q9. The output of the risk assessment can include changes to manufacturing process ECs that range from high to ICH Q12 Guideline low risk to product quality. The reporting category should be defined based on level of risk. A justification of the potential risk for changing ECs and corresponding reporting categories should be provided. A decision tree which illustrates the above step-wise approach to identifying ECs and reporting categories for process parameters is shown in Figure 1. The principles in the decision tree can be applied to identify ECs for other parts of the manufacturing process and control strategy (e.g., relevant elements of input material attributes, equipment, and in-process controls) and associated reporting categories. *[Figure 1: Decision Tree for Identification of ECs and Associated Reporting Categories]* for Manufacturing Process Parameters The details of ECs and the associated reporting category will depend on the extent to which the company can apply knowledge from product and process understanding (i.e., development and experience accumulated throughout the product lifecycle) to manage the risks to product quality. Different approaches can be used alone, or in combination, to identify ECs for manufacturing processes; these include, but are not limited to the following: • Parameter-based approaches, including: o A minimal2 approach, with a limited understanding of the relationship between inputs and resulting quality attributes, will include a large number of inputs (e.g., process parameters and material attributes) along with outputs (including in-process tests). 2 Also referred to as “traditional” in ICH Q11. ICH Q12 Guideline o An enhanced approach with increased understanding of interaction between inputs and product quality attributes together with a corresponding control strategy can lead to identification of ECs that are focused on the most important input parameters along with outputs, as appropriate. • In a performance-based approach, ECs could be primarily focused on control of process outputs (e.g., attributes, measurements, responses) rather than process inputs (e.g., process parameters and material attributes). This is enabled by knowledge gained from an enhanced approach, a data-rich environment, and an enhanced control strategy (e.g., models, Process Analytical Technology (PAT)). For example, a performance-based approach could be considered for manufacturing process steps with in-line monitoring of relevant attributes or with feedback controls or optimisation algorithms to achieve the relevant targets for that process step. When considering this approach, it is important to ensure that all relevant parameters and material attributes that have a potential to impact product quality are monitored and equipment used remains qualified in order to assure a stable process It should be noted that not all elements of the decision tree in Figure 1 apply because the enhanced control strategy used may remove the need for certain process parameters to be ECs. Use of this guideline should not lead to providing a less detailed manufacturing process description in the MAA. A suitably detailed description of the manufacturing process in Module 3 is expected to provide a clear understanding regardless of the approach used to identify ECs for manufacturing process parameters. Manufacturing process descriptions include supportive information as well as identified ECs. Information regarding product-specific post-approval change activities, such as post-change monitoring, may be provided as supporting information to aid in the determination of ECs and associated reporting categories. Criticality and risk should be periodically reviewed (as expected by ICH Q10) during the lifecycle of the product and the ECs and reporting categories should be updated based on acquired knowledge. When implementing the change, and consistent with Appendix 2, an MAH should consider the impact of the planned change, whether concurrent changes are planned, and if the originally proposed reporting category should be revised. This guidance does not impose additional regulatory filing expectations for process ECs due to non-conformance during routine operations. Non-conformance to process- related ECs should be handled in accordance with GMP regulations (i.e., deviation/non- conformance handling process). ##### 3.2.3.2 Identification of ECs for Analytical Procedures Similar to the principles described for manufacturing process, ECs related to analytical procedures should include elements which assure performance of the procedure. The extent of ECs and their reporting categories could vary based on the degree of the understanding of the relationship between method parameters and method performance, the method complexity, and control strategy. A justification to support the identification of ECs and corresponding reporting categories for changes to ECs based on risk management should be provided. Different approaches can be used to identify ECs for analytical procedures, for example as analytical technology and development approaches advance; these approaches include, but are not limited to the following: ICH Q12 Guideline • When more limited development studies have been conducted this may result in a narrow operating window to ensure method performance. In such cases ECs may be more extensive with fixed and/or tight conditions. • Enhanced understanding can lead to a wider operating window that ensures method performance, where ECs can be reduced and focused on method performance (e.g., method parameters acceptable ranges rather than set points, performance criteria). Use of this guideline should not lead to providing a less detailed description of analytical procedures in the MAA. A suitably detailed description of the analytical procedures in Module 3 is expected to provide a clear understanding regardless of the approach used to identify ECs for analytical procedures. Description of analytical procedures includes supportive information as well as identified ECs. #### 3.2.4 Revision of ECs It may be necessary to change approved ECs as a result of knowledge gained during the product lifecycle (e.g., manufacturing experience, introduction of new technologies or changes in the control strategy). Options available for the MAH to change approved ECs, and to revise the associated reporting category for approved ECs include: • Submission of an appropriate post-approval regulatory submission describing and justifying the proposed revision to the approved ECs. Justification may include information such as validation data and batch analyses. • Submission of a PACMP, in the original MAA or as part of a post-approval submission, describing a revision to ECs or reporting categories, and how the change will be justified and reported. • Use of an approved post-approval regulatory commitment, as appropriate. ### 3.3 Roles and Responsibilities The management of all changes to, and maintenance of, the approved marketing authorisation is the responsibility of the MAH. There is a joint responsibility to share and utilise information between the MAH and any manufacturing organisations to assure the marketing authorisation is maintained, reflects current operations, and that changes are implemented appropriately across relevant sites. Maintenance of the marketing authorisation should follow regional expectations. See Chapter 6 for information related to interactions between an MAH and any manufacturing organisations. For any referenced submission (e.g., Type II Drug Master File, Active Substance Master File) in an MAA, the holder of the referenced submission has a responsibility to communicate changes to their ECs to the MAH referencing their submission, so that the MAH can assess the impact of the change and report any related change to the ECs found in the approved MAA, as necessary and per regional requirements. The approval of ECs and subsequent changes to ECs is the responsibility of the regulatory authorities. ICH Q12 Guideline POST-APPROVAL CHANGE MANAGEMENT PROTOCOL (PACMP) ### 4.1 Definition of a PACMP A PACMP is a regulatory tool that provides predictability and transparency in terms of the requirements and studies needed to implement a change as the approved protocol provides an agreement between the MAH and the regulatory authority. A protocol describes the CMC change an MAH intends to implement during the commercial phase of a product lifecycle, how the change would be prepared and verified, including assessment of the impact of the proposed change, and the suggested reporting category in line with regional regulations and guidance, i.e., a lower reporting category and/or shortened review period as compared to similar change procedure without an approved PACMP. The PACMP also identifies specific conditions and acceptance criteria to be met. A PACMP can address one or more changes for a single product, or may address one or more changes to be applied to multiple products (see section 4.5). The PACMP may be submitted with the original MAA or subsequently as a standalone submission and can be proposed independent of any prior identification of ECs. The PACMP requires approval by the regulatory authority, and the conditions and acceptance criteria outlined in the protocol must be met and results communicated to the regulatory authority in the manner previously agreed, in order to implement the change(s). A PACMP should describe changes with a level of detail commensurate with the complexity of the change. Once approved, there is an expectation that the validity of the proposed approach and control strategy is confirmed prior to implementation of the change(s). For example, if new information becomes available following approval of the protocol, the risk assessment provided in the initial PACMP submission should be reviewed by the MAH before implementing the change(s), to ensure that the outcomes of that risk assessment as they pertain to the planned change(s) are still valid. If the review of the initial risk assessment indicates an increased level of risk associated with execution of the change, the previously approved reporting category should no longer be considered appropriate; instead, existing regional regulation or guidance should be followed or the relevant regulatory authority consulted. The MAH is responsible for ensuring that whenever a CMC change is to be introduced under a PACMP, the facility meets the regulatory requirements of the regulatory jurisdiction where the PACMP was approved with respect to GMP compliance, and inspection or licensing status. ### 4.2 Application of a PACMP The application of a PACMP process typically involves the following two steps: Step 1: Submission of a written protocol that describes the proposed change(s), its rationale(s), risk management activities, proposed studies and acceptance criteria to assess the impact of the change(s), other conditions to be met (e.g., confirmation that there is no change to the approved specification), the proposed reporting category for the change(s), and any other supportive information (see also below). The PACMP document can be located in CTD Module 3.2.R.3 This protocol is reviewed and approved by the regulatory authority in advance of execution of the protocol. 3 In some regions, the PACMP may be included in other modules. ICH Q12 Guideline Step 2: The tests and studies outlined in the protocol are performed. If the results/data generated meet the acceptance criteria in the protocol and any other conditions are met, the MAH submits this information to the regulatory authority according to the categorisation (classification) in the approved protocol for review by the regulatory authority as appropriate. Depending on the reporting category, approval by the regulatory authority may or may not be required prior to implementation of the change. If the acceptance criteria and/or other conditions in the protocol (see step 1) are not met, the change cannot be implemented using this approach and should instead follow existing regulation or guidance and associated reporting category. Significant changes to the manufacturing process or controls that were not anticipated in the PACMP step 1 (e.g., change of order of unit operations) cannot be implemented as part of step 2 and should be the subject of a regulatory submission as governed by regional regulation or guidance. However, minor unanticipated modifications of the process or controls related to the intended change and not affecting the technical principles of the protocol are normally considered within scope, if appropriately justified. No change outlined in a PACMP should introduce any additional risks to patient safety, product quality or efficacy. A CMC change that would require supportive efficacy, safety (clinical or non-clinical), or human PK/PD data to evaluate the effect of the change (e.g., certain formulation changes, clinical or non-clinical studies to evaluate new impurities, assessment of immunogenicity/antigenicity) is not suitable for inclusion in a PACMP. ### 4.3 Elements of a PACMP The development of the PACMP is informed by the application of process and product understanding gained from product development and/or manufacturing experience. A PACMP would typically include the following, e.g.: • A detailed description of the proposed change(s), including a rationale. The differences before and after the proposed change(s) should be clearly highlighted (e.g., in a tabular format). • Based on an initial risk assessment, a list of specific tests and studies to be performed to evaluate the potential impact of the proposed change(s), such as: characterisation, batch release, stability (as appropriate, see Chapter 9), in- process controls. The PACMP should include an appropriate description of the analytical procedures and proposed acceptance criteria for each test or study. • Discussion regarding the suitability of the approved control strategy or any changes needed to the control strategy associated with the planned change(s). • Any other conditions to be met, such as confirmation that certain process qualification steps will be completed before implementation. • Where applicable, supportive data from previous experience with the same or similar products related to: development, manufacturing, characterisation, batch release, and stability to allow for risk mitigation. • Proposed reporting category for step 2 of the PACMP. ICH Q12 Guideline • Confirmation, as appropriate, that ongoing verification will be performed under the PQS to continue to evaluate and ensure that there is no adverse effect of the change(s) on product quality. In cases where monitoring of the impact on product quality following implementation of the change(s) is required, a summary of the quality risk management activities should be provided to support the proposed PACMP. If multiple changes are to be implemented, these activities should address the potential risk from the cumulative effect of multiple changes and how they are linked. The MAH should demonstrate in the PACMP suitable scientific knowledge and understanding of aspects impacted by the proposed change in order to conduct an appropriate risk assessment of the proposed change(s). Typically, more complex changes would require enhanced product/process understanding. ### 4.4 Modification to an Approved PACMP A modification to an already approved PACMP, such as replacement or revision of a test, study or acceptance criterion, should provide the same or greater capability to assess the effect of the proposed change on the product quality and would normally involve a notification type of communication with the regulatory authority. A modification that more significantly alters the content of the protocol may require either prior approval of a protocol amendment or submission of a new protocol, as agreed upon with the regulatory authority. ### 4.5 Types of PACMPs There are different types of PACMPs: • One or more change(s) associated with a single product – see above and Annexes ID and 1E, for content and implementation. A PACMP can also be designed to be used repeatedly to make a specified type of CMC change over the lifecycle of a product, applying the same principles. If the protocol describes several changes for a particular product, a justification should be added showing how the changes are related and that inclusion in a single protocol is appropriate. • Broader protocols – the general principles outlined above apply. The risk of the proposed change(s) should be similar across products; additional considerations should be taken into account depending on the approach, for example: a. One or more changes to be implemented across multiple products (e.g., change in stopper across multiple products that use the same container closure system): the same risk mitigation strategy should be applicable across all impacted products; b. One or more changes to be implemented across multiple products and at multiple sites (e.g., change in analytical method across multiple sites, change in manufacturing site(s) across multiple products): the same risk mitigation strategy should be applicable across all impacted products and/or sites (see Annex IE). ICH Q12 Guideline PRODUCT LIFECYCLE MANAGEMENT (PLCM) DOCUMENT The PLCM document outlines the specific plan for product lifecycle management that includes the ECs, reporting categories for changes to ECs, PACMPs (if used) and any post-approval CMC commitments. Its purpose is to encourage prospective lifecycle management planning by the MAH and to facilitate regulatory assessment and inspection. The PLCM document should be updated throughout the product lifecycle as needed. ### 5.1 PLCM Document: Scope The PLCM document serves as a central repository in the MAA for ECs and reporting categories for making changes to ECs. It includes the key elements described below and references to the related information located elsewhere in the MAA (see Annex IF). Submission of the PLCM document is critical when the MAH proposes ECs in line with the risk-based approaches in Chapter 3. The elements of the PLCM document are summarised below: • ECs (refer to Chapter 3): The ECs for the product should be listed in the PLCM document. The identification and justification of ECs are located in the relevant sections of the CTD. • Reporting category for making changes to approved ECs (refer to Chapter 3): The reporting categories when making a change to an EC should be listed in the PLCM document. The detailed justification of the reporting categories is located in the relevant sections of the CTD. • PACMPs (refer to Chapter 4): PACMPs that are submitted to prospectively manage and implement one or more post-approval changes should be listed. • Post-approval CMC commitments: specified CMC development activities, agreed between the MAH and regulatory authority at the time of approval (e.g., specific process monitoring, additional testing) that will be performed during the commercial phase should be listed in the PLCM document. ### 5.2 Submitting the PLCM Document The PLCM document is submitted in the original MAA or in a supplement/variation for marketed products when defining ECs (Chapter 3). ### 5.3 Maintenance of the PLCM Document An updated PLCM document should be included in post-approval submissions for CMC changes. The updated PLCM document will capture the change in ECs and other associated elements (reporting category, commitments, PACMP). The MAH should follow regional expectations for maintaining a revision history for the PLCM document. ### 5.4 Format and Location of PLCM Document A tabular format is recommended to capture certain elements of PLCM described in section 5.1, but other appropriate formats can be used. See Annex IF for an example PLCM table. ICH Q12 Guideline The PLCM document can be located in CTD Module 3.2.R.4 PHARMACEUTICAL QUALITY SYSTEM (PQS) AND CHANGE MANAGEMENT ### 6.1 PQS General Considerations An effective PQS as described in ICH Q10 and in compliance with regional GMP requirements where the application is filed, is necessary across the entire supply chain and product lifecycle to support use of the tools described in this guideline. It includes appropriate change management, enabled by knowledge management, and management review. The principles are further elaborated in Appendix 2. The relationship between knowledge management, change management, and the regulatory process for ECs are illustrated in Figure 2. *[Figure 2: Connection Between Knowledge Management and Change]* Management Process Maintaining an effective PQS is the responsibility of a company (manufacturing sites and MAH where relevant). It is not the intent of this guideline to require a specific inspection assessing the state of the PQS before the company can use the principles in this guideline. The conduct of inspections in connection with submitted MAAs and surveillance will nevertheless continue as foreseen by regional regulatory requirements. It is understood that a manufacturing site can be considered to be in general GMP compliance while resolving deficiencies that do not require regulatory action. In the event that such deficiencies have an impact on the effectiveness of change management 4 In some regions, the PLCM may be included in Module 1. ICH Q12 Guideline in the PQS, it may result in restrictions on the ability to utilise flexibility in this guideline. ### 6.2 Change Management Across the Supply Chain and Product Lifecycle Supply chains involve multiple stakeholders (e.g., MAHs, R&D organisations, manufacturers, Contract Manufacturing Organisations, suppliers). It is important that these stakeholders interact to effectively utilise knowledge and manage changes during the product lifecycle. A company has to manage communication of information and interactions of PQSs across multiple entities (internal and external). Therefore, the implementation of robust change management across multiple sites (outsourced or not) is necessary. In conjunction with change control principles in Appendix 2, the following change management activities should be considered to support the approaches defined in this guideline: • Changes to ECs should be communicated in a timely fashion between the MAH and the regulators, and between the MAH and the manufacturing chain (and vice versa). • The timeliness of communication is driven by the impact of any change related to ECs and should be targeted to those entities in the chain that need to be aware of or to implement the change over the lifecycle of the product. • Process knowledge and continual improvement are drivers for change. For example, a CMO may be in a position to propose process improvements which significantly improve control and product consistency. These data can be utilised to revise the ECs and associated PLCM document. The organisation responsible for batch release should be aware of all relevant changes and where applicable, be involved in the decision making. • The communication mechanisms regarding MAA changes and GMP issues should be defined in relevant documentation, including contracts with CMOs. • A critical failure in a PQS anywhere in the supply chain may impact the ability to use the tools in this guideline; therefore, the company should communicate such failures to affected regulatory authorities. RELATIONSHIP BETWEEN REGULATORY ASSESSMENT AND INSPECTION Regulatory assessment and inspection are complementary activities and their fundamental roles remain unchanged by this guideline. Nevertheless, effective communication between assessors and inspectors can facilitate regulatory oversight of product lifecycle management. Appropriate mechanisms to share knowledge and information obtained through inspection or assessment activities can facilitate access to necessary information and mitigate increased submission burden on the MAH. For example, the conclusions from inspections should be available to assessors to support ongoing oversight of product lifecycle management and the most recent PLCM document, when applicable, should be available to inspectors so they are aware of the currently approved status of the PLCM elements. ICH Q12 Guideline Communication is encouraged between regulators across regions, in accordance with appropriate bilateral/multilateral arrangements; for example, to communicate about critical failures in aspects of a company’s PQS that may impact the use of tools described in this guideline. STRUCTURED APPROACHES FOR FREQUENT CMC POST-APPROVAL CHANGES In addition to the other tools described in this guideline, a simplified approach to accomplish certain CMC changes is needed for products whose marketing authorization did not involve identification of ECs with associated reporting categories. This chapter describes a strategy for a structured approach for frequent CMC changes and includes a discussion of the data requirements for CMC changes (e.g., stability). The strategy described for structured approaches to frequent CMC changes is exemplified with a description of an approach for analytical procedure changes in Annex II. Similar structured approaches could be developed and applied for other frequent CMC changes such as scale, packaging, etc. These approaches may be applied when the following conditions exist: • The company’s PQS change management process is effective and in compliance as described in Chapter 6 and incorporates an appropriate risk management system. • A structured approach can be found in Annex II and describes the scope and the steps to be followed, including, where appropriate, data to be generated and criteria to be met. Compliance with the requirements of relevant internationally-agreed Standards and/or regulatory guidelines may be specified as part of the structured approach. If the approach is followed and all criteria are met, the change can be made with immediate or other post-implementation notification, as appropriate, to the relevant regulatory authorities. The flexibility provided in Annex II may not be available in all regions and in all situations; some specific changes may require prior approval as defined in regional guidance. STABILITY DATA APPROACHES TO SUPPORT THE EVALUATION OF CMC CHANGES The data needed for submission to the regulatory authority in support of a post-approval change is established by regional regulations and guidance. This guideline provides additional science- and risk-based approaches that can be used to develop strategies for confirmatory stability studies supporting post-approval changes to enable more timely filing, approval, and implementation of the changes. Such approaches could be included in a PACMP (see Annexes ID and IE). Unlike the formal stability studies recommended in ICH Q1A(R2), whose objective is to establish a useful shelf-life and storage conditions for a new, yet-to-be-marketed drug substance/drug product, the purpose of stability studies, if needed, to support a post- approval CMC change is to confirm the previously approved shelf-life and storage conditions. The scope and design of such stability studies are informed by the knowledge and experience of the drug product and drug substance acquired since authorisation. Approaches to the design of such studies should be appropriately justified and may include: ICH Q12 Guideline • Identifying the stability-related quality attributes and shelf-life-limiting attributes relative to the intended CMC changes, based on risk assessments and previously generated data • Use of appropriate tools to evaluate the impact of the intended change. These may include: o Drug substance and/or drug product accelerated and/or stress studies on representative material (which may be pilot or laboratory scale rather than full scale) o Pre-and post-change comparability studies on representative material o Statistical evaluation of relevant data including existing stability studies o Predictive degradation and other empirical or first-principles kinetic models o Utilisation of prior knowledge including relevant company knowledge and the scientific literature • Use of confirmatory stability studies post-change instead of submission of data as part of a regulatory change submission Where applicable, a commitment to initiate or complete ongoing, long-term stability testing on post-change batches can assure that the approved shelf life and storage conditions continue to be applicable after implementing the CMC change. 10 GLOSSARY Term Definition CAPA Corrective Action and Preventive Action – System that focuses on investigating, understanding, and correcting discrepancies while attempting to prevent their occurrence CMO Contract Manufacturing Organisation CPP Critical Process Parameter – process parameter whose variability has an impact on a critical quality attribute and therefore should be monitored or controlled to assure the process produces the desired product quality. (Q8(R2)) CQA Critical Quality Attribute – a physical, chemical, biological or microbiological property or characteristic that should be within an appropriate limit, range, or distribution to assure the desired product quality. (Q8(R2)) CTD Common Technical Document Company Manufacturing sites and MAH where relevant EC Established Condition MAA Marketing Authorisation Application ICH Q12 Guideline Term Definition MAH Marketing Authorisation Holder Notification A change to an approved established condition that does not require approval prior to implementation. PACMP Post-Approval Change Management Protocol PLCM Product Lifecycle Management Post-approval CMC commitment Commitment by the MAH to undertake specific CMC activities to be implemented during the commercial phase. Prior approval Change to an approved established condition that requires regulatory review and approval prior to implementation PQR Product Quality Review – regular periodic review of API or drug products with the objective to verify process consistency, to highlight any trends and to identify product and process improvements PQS Pharmaceutical Quality System QRM Quality Risk Management Submission Communication to a regulatory authority regarding a change to an established condition that could be prior approval or notification. 11 REFERENCES ICH M4: The CTD -- Quality ICH Q1A(R2) Stability Testing of New Drug Substances and Products ICH Q2(R1) Validation of Analytical Procedures: Text and Methodology ICH Q5E Comparability of Biotechnological/Biological Products Subject to Changes in Their Manufacturing Process ICH Q8(R2) Pharmaceutical Development ICH Q9 Quality Risk Management ICH Q10 Pharmaceutical Quality System ICH Q11 Development and Manufacture of Drug Substances ICH Q8, Q9, and Q10 Questions and Answers ICH Q8, Q9, & Q10 Questions and Answers -- Appendix: Q&As from Training Sessions (Q8, Q9, & Q10 Points to Consider) ## APPENDIX 1: CTD SECTIONS THAT CONTAIN ECS Notes: • This table does not contain a complete list of ECs for a product. The intention of the table is to provide general guidance about the elements of manufacture and control that constitute ECs and their location within the CTD structure. • White rows indicate CTD sections where ECs are generally located. Grey rows indicate CTD sections where supportive information is generally located. • CTD sections containing ECs may also contain elements of supportive information. • For information related to the drug delivery system for a drug-device combination product, the location or the relevant content within the CTD structure may vary depending on the design of the particular product and region. CTD SECTION SECTION TITLE ESTABLISHED CONDITIONS – General List with notes 3.2.S DRUG SUBSTANCE 3.2.S.1 General Information 3.2.S.1.1 Nomenclature Drug Substance Name, Structure. 3.2.S.1.2 Structure 3.2.S.1.3 General properties Supportive information 3.2.S.2 Manufacture 3.2.S.2.1 Manufacturer(s) Drug Substance Manufacturing Site(s) (including testing) 3.2.S.2.2 Description of manufacturing process and process controls Individual unit operations and their sequence in the manufacturing process For levels/details of ECs for inputs (process parameters and material attributes) and outputs of individual unit operations, reference is made to Chapter 3, section 3.2.3.1 – Identification of ECs for the Manufacturing Processes 3.2.S.2.3 Control of Materials Starting material specifications (test, elements of analytical procedure and acceptance criteria) Raw material/reagent/solvent critical controls ICH Q12 Guideline CTD SECTION SECTION TITLE ESTABLISHED CONDITIONS – General List with notes Source of materials (e.g., cell and seed source, raw materials) and control of critical materials of biological origin Generation and control of Master - Working Cell Bank / Master - Working Seed Lot, etc. (Applicable to biotechnological/biological products) 3.2.S.2.4 Control of critical steps and intermediates Specifications (e.g., test, elements of analytical procedure and acceptance criteria) for critical steps and intermediates which may include storage conditions of critical intermediates 3.2.S.2.5 Process validation and/or evaluation Supportive information 3.2.S.2.6 Manufacturing process development Supportive information 3.2.S.3 Characterisation Supportive information 3.2.S.3.1 3.2.S.3.2 Elucidation of structure and other characteristics Impurities Supportive information 3.2.S.4 Control of Drug Substance 3.2.S.4.1 Specification Drug Substance Specification For each Quality Attribute on the specification • Test Method • Acceptance Criteria 3.2.S.4.2 Analytical Procedures Reference is made to Chapter 3, section 3.2.3.2 Identification of ECs for Analytical Procedures 3.2.S.4.3 Validation of analytical procedure Supportive information 3.2.S.4.4 Batch analyses Supportive information ICH Q12 Guideline CTD SECTION SECTION TITLE ESTABLISHED CONDITIONS – General List with notes 3.2.S.4.5 Justification of specification Supportive information 3.2.S.5 Reference Material Reference Material specification (e.g., test, elements of analytical procedure, where appropriate, and acceptance criteria) 3.2.S.6 Container Closure Material of construction and specification 3.2.S.7 Stability 3.2.S.7.1 Stability Summary and Conclusions Drug Substance storage conditions and shelf-life (or Retest period for chemicals) 3.2.S.7.2 Post-approval stability protocol and stability commitments Supportive information (also see Chapter 3, section 3.2.2) 3.2.S.7.3 Stability data Supportive information 3.2.P DRUG PRODUCT 3.2.P.1 Description and Composition of Drug Product Drug Product qualitative and quantitative composition 3.2.P.2 Pharmaceutical development 3.2.P.2.1 Components of the drug product Supportive information 3.2.P.2.2 Drug product 3.2.P.2.3 Manufacturing process development 3.2.P.2.4 Container closure system 3.2.P.2.5 Microbiological attributes 3.3.P.2.6 Compatibility 3.2.P.3 Manufacture ICH Q12 Guideline CTD SECTION SECTION TITLE ESTABLISHED CONDITIONS – General List with notes 3.2.P.3.1 Manufacturer(s) Drug Product Manufacturing sites (including those for testing, primary and secondary packaging, device assembly for drug product-device combination products 3.2.P.3.2 Batch Formula Drug Product Batch Formula (Qualitative and Quantitative) 3.2.P.3.3 Description of manufacturing process and process controls Individual unit operations and their sequence in the manufacturing process For levels/details of ECs for inputs (process parameters and material attributes) and outputs of individual unit operations, reference is made to Chapter 3, section 3.2.3.1 3.2.P.3.4 Controls of Critical Steps and Intermediates Specifications (e.g., test, elements of analytical procedure and acceptance criteria) for critical steps and intermediates which may include storage conditions of critical intermediates. 3.2.P.3.5 Process validation and/or evaluation Supportive information 3.2.P.4 Control of Excipients 3.2.P.4.1 Specifications Excipient Specification For each Quality Attribute on the specification • Test Method • Acceptance Criteria Or, if applicable, Reference to pharmacopoeial monograph 3.2.P.4.2 Analytical Procedures Reference to pharmacopoeial monograph and if none exists, refer to Chapter 3, section 3.2.3.2 3.2.P.4.3 Validation of analytical procedures Supportive information 3.2.P.4.4 Justification of specifications Supportive information 3.2.P.4.5 Excipients of Human or Animal Origin Excipient source and controls ICH Q12 Guideline CTD SECTION SECTION TITLE ESTABLISHED CONDITIONS – General List with notes 3.2.P.4.6 Novel excipients (If Novel Excipient Specification is not described in 3.2.P.4.1) Novel Excipient Specification For each Quality Attribute on the specification • Test Method • Acceptance Criteria 3.2.P.5 Control of Drug Product 3.2.P.5.1 Specification(s) Drug Product Specification For each Quality Attribute on the specification • Test Method • Acceptance Criteria 3.2.P.5.2 Analytical Procedures Reference is made to Chapter 3, section 3.2.3.2 3.2.P.5.3 Validation of analytical procedures Supportive information 3.3.P.5.4 Batch analyses Supportive information 3.2.P.5.5 Characterisation of impurities 3.2.P.5.6 Justification of specification(s) 3.2.P.6 Reference Materials Reference material specification (e.g., test, elements of analytical procedure, where appropriate, and acceptance criteria) 3.2.P.7 Container Closure System Material of construction and specification Where applicable, supplier/manufacturer of primary container closure system 3.2.P.8 Stability ICH Q12 Guideline CTD SECTION SECTION TITLE ESTABLISHED CONDITIONS – General List with notes 3.2.P.8.1 Stability Summary and Conclusion Drug product storage conditions and shelf-life Where applicable, in-use storage conditions and shelf-life 3.2.P.8.2 Post-approval stability protocol and stability commitment Supportive information (also see Chapter 3, section 3.2.2) 3.3 P.8.3 Stability data Supportive information 3.2.A APPENDICES 3.2.A.1 Facilities and equipment Regional regulation and guidance apply 3.2.A.2 Adventitious agents safety evaluation Supportive information (Applicable to biotechnological/biological products) 3.2.A.3 Excipients Supportive information 3.2.R REGIONAL INFORMATION Not Applicable Regional regulation and guidance apply. ## APPENDIX 2: PRINCIPLES OF CHANGE MANAGEMENT Consistent with the basic requirements of ICH Q10, an effective change management system supports the principles of this guideline and is described below: 1. Captures stimuli for change, including those that can improve product performance or process robustness; 2. Ensures full understanding of the scope of the change and its implications for all aspects of the process and control strategy including the impact on ECs and aspects that are not ECs in affected marketing authorisations; 3. Leverages existing process performance and product quality knowledge; 4. Requires science-based risk management and risk categorisation of the intended change; considers the potential impact if the intended change is not implemented; 5. Determines data (existing and/or to be newly generated) needed to support the change and accordingly develops study protocols describing the methods, prospective acceptance criteria as well as additional post-implementation process performance and/or product quality monitoring as necessary; 6. Ensures that an appropriate regulatory submission is filed when required; 7. Uses a defined change control process to approve or reject the intended change and involve appropriate stakeholders, including but not restricted to Manufacturing, Quality, and Regulatory Affairs personnel; 8. Ensures implementation of the change is based on: a. Review that the change as implemented remains aligned with the relevant study protocols, PLCM document, or PACMP; b. Assessment of data generated to demonstrate that the change objective and acceptance criteria were met; 9. Ensures that risk-mitigating steps are developed in the case of deviations from acceptance criteria, or identification of unanticipated risks; 10. Verifies, post-implementation, that relevant changes have been effective in achieving the desired outcome with no unintended consequences for product quality; If deviations associated with post-approval changes are detected, ensures that the issue is managed via the company’s deviation management process and appropriate corrective and/or preventive actions are identified and undertaken via the company’s corrective and preventive action (CAPA) system; 11. Post-implementation: a. Captures new product/process knowledge gained during implementation of the change; ICH Q12 Guideline b. Where applicable, ensures that regulatory filings are updated, and an assessment is made as to whether updates to the PLCM document are needed; c. Where applicable, ensures that the change is included and assessed as part of the Product Quality Review (PQR); 12. The change management system should be available for review during audit/inspection. Use of Knowledge in Change Management An effective change management system includes active knowledge management, in which information from multiple sources is integrated to identify stimuli for changes needed to improve product and/or process robustness. The connection between knowledge management and change management is illustrated in Figure 2. These sources can include, but are not limited to, developmental studies, process understanding documents, product or process trending, and product-specific CAPA outcomes. Provisions should be made for sharing knowledge (e.g., in quality agreements and/or contracts) that relates to product and process robustness or otherwise informs changes between the MAH and relevant manufacturing stakeholders (research and development organisations, manufacturers, CMOs, suppliers, etc.). In addition to individual sources of information, there should be a mechanism to provide a holistic view of quality performance for a specific product or product family on a regular basis, as captured in the product quality review (PQR) and shown in Figure 2. This should include steps taken to identify and manage sources of variability, which allows for the identification of further need for change not apparent when the data are viewed in isolation. As described in ICH Quality Implementation Working Group on Q8, Q9, and Q10 Questions & Answers, there is no added regulatory requirement for a formal knowledge management system. Management Review In addition to the guidance provided in ICH Q10 regarding an effective change management system, the following should be considered in the Management Review: • Monitoring the timeliness of the change management system to assure that changes are implemented in a timely manner commensurate with the criticality/urgency identified for the change. When implementation is delayed, an assessment and mitigation of any risks associated with the delay should be made; • Monitoring the performance of the change management system, such as assessing the frequency of intended changes that are not approved for implementation by the quality unit; • Ensuring that post-implementation verification occurs and reviewing the results of that verification as a measure of change management effectiveness (e.g., to identify improvements to the change management system). --- ### Document: ICH Q13 Complete (ICH) # ICH Harmonised Guideline Q13 (2022): Continuous Manufacturing of Drug Substances and Drug Products INTERNATIONAL COUNCIL FOR HARMONISATION OF TECHNICAL REQUIREMENTS FOR PHARMACEUTICALS FOR HUMAN USE ICH HARMONISED GUIDELINE CONTINUOUS MANUFACTURING OF DRUG SUBSTANCES AND DRUG PRODUCTS Q13 Final version Adopted on 16 November 2022 This Guideline has been developed by the appropriate ICH Expert Working Group and has been subject to consultation by the regulatory parties, in accordance with the ICH Process. At Step 4 of the Process the final draft is recommended for adoption to the regulatory bodies of ICH regions Q13 Document History Code History Date Q13 Endorsement by the Members of the ICH Assembly under Step 2 and release for public consultation. 27 July 2021 Q13 Adoption by the Regulatory Members of the ICH Assembly under Step 4. 16 November 2022 Legal notice: This document is protected by copyright and may, with the exception of the ICH logo, be used, reproduced, incorporated into other works, adapted, modified, translated or distributed under a public license provided that ICH's copyright in the document is acknowledged at all times. In case of any adaption, modification or translation of the document, reasonable steps must be taken to clearly label, demarcate or otherwise identify that changes were made to or based on the original document. Any impression that the adaption, modification or translation of the original document is endorsed or sponsored by the ICH must be avoided. The document is provided "as is" without warranty of any kind. In no event shall the ICH or the authors of the original document be liable for any claim, damages or other liability arising from the use of the document. The above-mentioned permissions do not apply to content supplied by third parties. Therefore, for documents where the copyright vests in a third party, permission for reproduction must be obtained from this copyright holder. i ICH HARMONISED GUIDELINE CONTINUOUS MANUFACTURING OF DRUG SUBSTANCES AND DRUG PRODUCTS Q13 ICH Consensus Guideline TABLE OF CONTENTS PART I: CONTINUOUS MANUFACTURING OF DRUG SUBSTANCES AND DRUG PRODUCTS................................................................................................................................... 1 1. INTRODUCTION ................................................................................................................. 1 1.1. Objective .................................................................................................................................. 1 1.2. Scope ........................................................................................................................................ 1 2. CM CONCEPTS .................................................................................................................... 1 2.1. Different Modes of CM ........................................................................................................... 1 2.2. Batch definition........................................................................................................................ 2 3. SCIENTIFIC APPROACHES ............................................................................................. 2 3.1. Control Strategy ....................................................................................................................... 2 3.2. Changes in Production Output ................................................................................................. 6 3.3. Continuous Process Verification ............................................................................................. 7 4. REGULATORY CONSIDERATIONS ............................................................................... 7 4.1. Description of Manufacturing Process and Process Controls .................................................. 8 4.2. Control Strategy ....................................................................................................................... 8 4.3. Batch Description and Batch Size ......................................................................................... 10 4.4. Process Models ...................................................................................................................... 10 4.5. Drug Substance and Drug Product Stability .......................................................................... 10 4.6. Conversion of a Batch Process to CM ................................................................................... 11 4.7. Process Validation ................................................................................................................. 11 4.8. Pharmaceutical Quality System ............................................................................................. 12 4.9. Lifecycle Management .......................................................................................................... 12 4.10. Submission of CM-Specific Information in the CTD .......................................................... 12 ii 5. GLOSSARY ......................................................................................................................... 15 6. REFERENCES .................................................................................................................... 16 PART II: ANNEXES .................................................................................................................. 18 ANNEX I: CONTINUOUS MANUFACTURING OF DRUG SUBSTANCES (CHEMICAL ENTITIES) .................................................................................................................................. 18 1. INTRODUCTION AND EXAMPLE SYSTEM OVERVIEW ....................................... 18 2. CONTROL STRATEGY AND OTHER TECHNICAL CONSIDERATIONS ............ 19 2.1. Equipment Design and Integration ........................................................................................ 19 2.2. Process Control and Monitoring ............................................................................................ 19 2.3. Consideration of Other Controls ............................................................................................ 21 2.4. Process Validation ................................................................................................................. 21 3. REGULATORY CONSIDERATIONS ............................................................................. 22 ANNEX II: CONTINUOUS MANUFACTURING OF DRUG PRODUCTS (CHEMICAL ENTITIES) .................................................................................................................................. 23 1. INTRODUCTION AND EXAMPLE SYSTEM OVERVIEW ....................................... 23 2. CONTROL STRATEGY AND OTHER TECHNICAL CONSIDERATIONS ............ 23 2.1. Material Characterisation and Control ................................................................................... 23 2.2. Equipment Design and Integration ........................................................................................ 24 2.3. Process Controls and Monitoring .......................................................................................... 25 2.4. Process Validation ................................................................................................................. 25 3. REGULATORY CONSIDERATIONS ............................................................................. 26 ANNEX III: CONTINUOUS MANUFACTURING OF DRUG SUBSTANCES (THERAPEUTIC PROTEINS) ................................................................................................. 27 1. INTRODUCTION AND EXAMPLE SYSTEM OVERVIEW ....................................... 27 2. CONTROL STRATEGY .................................................................................................... 28 2.1. Adventitious Agent Control ................................................................................................... 28 2.2. Equipment Design and System Integration ........................................................................... 28 2.3. Process Monitoring and Real-Time Release Testing ............................................................. 29 3. PROCESS VALIDATION .................................................................................................. 29 3.1. Approaches to Process Validation ......................................................................................... 29 3.2. Run Time Considerations ...................................................................................................... 30 3.3. Viral Clearance Validation .................................................................................................... 30 iii ANNEX IV: INTEGRATED DRUG SUBSTANCE AND DRUG PRODUCT CONTINUOUS MANUFACTURING ...................................................................................... 31 1. INTRODUCTION ............................................................................................................... 31 2. INTEGRATED SMALL MOLECULE DRUG SUBSTANCE/DRUG PRODUCT PROCESSES ............................................................................................................................... 31 2.1. Characteristics of Drug Substance and Drug Product Process Steps..................................... 31 2.2. Example of an Integrated Process .......................................................................................... 31 2.3. Process Design, Monitoring and Control ............................................................................... 33 2.4. Start-up and Shutdown........................................................................................................... 33 2.5. RTD Characterisation for System Dynamics and Material Traceability ............................... 33 3. SPECIFICATION AND BATCH DATA .......................................................................... 33 3.1. Drug Substance Specification ................................................................................................ 33 3.2. Drug Product Specification .................................................................................................... 34 3.3. Example of a Drug Substance and Drug Product Specification ............................................ 34 3.4. Batch Data.............................................................................................................................. 35 4. STABILITY REQUIREMENTS........................................................................................ 35 4.1. Drug Substance Stability ....................................................................................................... 35 4.2. Drug Product Stability ........................................................................................................... 36 5. LOCATION OF DRUG SUBSTANCE AND DRUG PRODUCT INFORMATION IN THE CTD ..................................................................................................................................... 36 ANNEX V: PERSPECTIVES ON MANAGING DISTURBANCES .................................... 37 1. INTRODUCTION ............................................................................................................... 37 2. BACKGROUND .................................................................................................................. 37 3. MANAGEMENT OF DISTURBANCES .......................................................................... 38 3.1. Disturbance Example 1 .......................................................................................................... 38 3.2. Disturbance Example 2 .......................................................................................................... 39 3.3. Disturbance Example 3 .......................................................................................................... 40 ICH Q13 Guideline PART I: CONTINUOUS MANUFACTURING OF DRUG SUBSTANCES AND DRUG PRODUCTS 1. INTRODUCTION 1.1. Objective This guideline describes scientific and regulatory considerations for the development, implementation, operation, and lifecycle management of continuous manufacturing (CM). Building on existing ICH Quality guidelines, this guideline provides clarification on CM concepts and describes scientific approaches and regulatory considerations specific to CM of drug substances and drug products. 1.2. Scope This guideline applies to CM of drug substances and drug products for chemical entities and therapeutic proteins. It is applicable to CM for new products (e.g., new drugs, generic drugs, biosimilars) and the conversion of batch manufacturing to CM for existing products. The principles described in this guideline may also apply to other biological/biotechnological entities. CM involves the continuous feeding of input materials into, the transformation of in-process materials within, and the concomitant removal of output materials from a manufacturing process. While this description may apply to an individual unit operation (e.g., process chromatography, tableting, perfusion cell culture), this guideline focuses on the integrated aspects of a CM system in which two or more unit operations are directly connected. In this context, any changes made in a unit operation of a CM system may have impact on downstream and upstream unit operations (e.g., back pressure resulting in forward mixing) and output material quality. Fundamental aspects of CM that are generally not specific to technology, dosage form, or molecule type are described within the main body of this guideline. Annexes are provided to augment the main guideline by providing illustrative examples and considerations specific to certain modalities (e.g., chemical entities, therapeutic proteins), technologies, and production methods (e.g., integration of drug substance and drug product manufacturing). The examples and approaches described in these annexes are illustrative, and alternative approaches can be used. Topics that are broadly applicable to both CM and batch manufacturing are not in the scope of this guideline, and other existing ICH guidelines should be used as appropriate. 2. CM CONCEPTS 2.1. Different Modes of CM CM can be applied to some or all unit operations in a manufacturing process. Examples of CM modes include: • A manufacturing approach in which some unit operations operate in a batch mode while others are integrated and operate in a continuous mode ICH Q13 Guideline • A manufacturing approach in which all unit operations of a drug substance or drug product manufacturing process are integrated and operate in a continuous mode • A manufacturing approach in which drug substance and drug product unit operations are integrated across the boundary between drug substance and drug product to form a single CM process (i.e., the drug substance is continuously formed and processed into the drug product through integrated unit operations) A manufacturing approach may incorporate surge lines or tanks to maintain a constant flow of material inputs and outputs in any mode of CM described above. 2.2. Batch definition The ICH Q7 definition of a batch is applicable to all modes of CM, for both drug substances and drug products. Based on this definition, the size of a batch produced by CM can be defined in terms of one of the following: • Quantity of output material • Quantity of input material • Run time at a defined mass flow rate Other approaches to define batch size are possible, if scientifically justified based on the characteristics of the CM process and Good Manufacturing Practice. A batch size can also be defined as a range. For example, a batch size range can be established by defining a minimum and maximum run time. 3. SCIENTIFIC APPROACHES 3.1. Control Strategy The development of a control strategy for CM is enabled by a holistic approach, considering aspects specific to CM (discussed below), principles outlined in ICH Q7, Q8, Q10 and Q11, and quality risk management described in ICH Q9. 3.1.1. State of Control A state of control (ICH Q10) is a condition that provides assurance of continued process performance and product quality. The condition may vary, depending on the mode of CM and the specific process steps. For example, a state of control can be demonstrated for CM processes when a set of parameters (e.g., process parameters, quality attributes) are changing within specified ranges, but the processes are not necessarily in a steady state. Elements of the control strategy monitor the state of control and, when necessary, take appropriate actions to maintain control of the process. It is important to have mechanisms in place to evaluate the consistency of unit operations and the system, and to identify when parameters drift or trend within the specified range. In addition, the root cause of drift or trend, such as variation of inputs, equipment fatigue, or aging of materials, should be identified. For example, in a therapeutic protein process, a change in the elution profile may be due to resin aging. ICH Q13 Guideline 3.1.2. Process Dynamics Knowledge of process dynamics is important to maintain a state of control in CM. Specifically, understanding the impact of transient events helps to identify risks to material quality and to develop an appropriate control strategy (see Section 3.1.5 for process monitoring and control considerations). Transient events that occur during CM operation may be planned (e.g., process start-up, shutdown and pause) or unplanned (e.g., disturbances) and can be described through time, process parameter and quality attribute values. Process dynamics should be characterised to understand how output material quality is impacted by transient events. This characterisation could be done by determining properties such as residence time distribution (RTD). RTD characterises the time available for material transport and transformation, and is specific to the process, composition/formulation, material properties, equipment design and configuration, etc. Additionally, understanding RTD and process dynamics enables the tracking of material and supports the development of sampling and diversion strategies, where applicable. Furthermore, such understanding is of importance from a process performance perspective. For example, changes in process dynamics or RTD may impact process characteristics, such as conversion/yield and impurity formation in the manufacture of drug substances. Process dynamics should be characterised over the planned operating ranges and anticipated input material variability using scientifically justified approaches. Appropriate methodologies (e.g., RTD studies, in silico modeling with experimental confirmation) should be used to understand the impact of process dynamics and its variation on material transport and transformation. These methodologies should not interfere with the process dynamics, and the characterisation should be relevant to the commercial process. For example, when conducting RTD studies, the tracer used to replace a constituent of the solid or liquid stream should have highly similar flow properties as those of the constituent replaced, be inert to the other components of the process, and not alter how processed materials interact with equipment surfaces. Step testing by making changes to the quantitative composition of the process stream (e.g., increments of a constituent) is another useful technique to determine the RTD and avoid the addition of an external tracer to the process. Other approaches can be used; the approach taken should be justified. 3.1.3. Material Characterisation and Control Material attributes can impact various aspects of CM operation and performance, such as material feeding, process dynamics, and output material quality. Understanding the impact of material attributes and their variability on process performance and product quality is important for the development of the control strategy. Input materials may require evaluation and control of attributes beyond those typically considered for a material specification used in batch manufacturing. For example: • In a solid dosage form process, particle size, cohesiveness, adhesiveness, hygroscopicity, static charge, or specific surface area of drug substances and excipients may impact the feeding of powders and material flow through the system. • In a chemically synthesised drug substance process, viscosity, concentration, or the multiphase nature of the feed may impact flow properties or conversion. ICH Q13 Guideline • In a therapeutic protein (e.g., monoclonal antibody) process, lot-to-lot variability of cell culture media or feed components may impact cell culture performance, process performance, or process consistency. 3.1.4. Equipment Design and System Integration The design of equipment and their integration to form a CM system affect process dynamics, material transport and transformation, output material quality, etc. When developing a CM process and its control strategy, it is important to consider the characteristics of the integrated systems in addition to the individual equipment that can affect process performance. These include the system’s ability to maintain an integrated flow, manage potential disruption to CM operations, and complete the intended transformation of the material stream within the respective planned operational ranges of the equipment. In addition, transfer steps should also be evaluated, including RTD, for the purposes of integration. Examples of design considerations are given below: • Design and configuration of equipment (e.g., compatibility and integrity of equipment components for the maximum run time or cycles; geometry of constituent parts to promote the desired transformation; spatial arrangement of equipment to facilitate material flow, maintenance, and avoid build-up or fouling) • Physical connections and digital control interfaces between equipment (e.g., use of a surge tank between two unit operations to mitigate temporary differences in mass flow rates) • Locations of material diversion and sampling points (e.g., selection of locations for a diverter valve and sampling probe without disturbing material flow and transformation) Furthermore, appropriate design or selection of equipment for a CM process may enable process simplification (e.g., through a reduction in the number of unit operations), facilitate process monitoring and material diversion, and improve process capability and performance. For example, in a drug substance process, reactor design can effectively reduce formation and build-up of impurities, resulting in fewer purification steps. Similarly, for therapeutic protein drug substance manufacturing, system design can enable process intensification and reduce cycle times. 3.1.5. Process Monitoring and Control Process monitoring and control support the maintenance of a state of control during production and allow real-time evaluation of system performance. Common approaches to process monitoring and control—including establishment of target setpoints and control limits, design space, and specifications for attributes being measured—are applicable to CM. Process analytical technology (PAT) (ICH Q8) is well-suited for CM. Example applications include in-line UV flow cells to monitor therapeutic protein concentration, in-line near-infrared spectroscopy to assess blend uniformity or water content, and on-line HPLC to monitor conversion of a chemical reaction. The use of PAT enables disturbances to be detected in real time. Therefore, CM is readily amenable to automated process control strategies based on, for example, active process control such as feedforward or feedback process control. Principles of control strategy as described in ICH Q8 and ICH Q11 are applicable to CM processes. ICH Q13 Guideline An appropriate sampling strategy is an important aspect of process monitoring and control. The variables monitored, monitoring method and frequency, amount of material sampled (either physical sampling or data sampling using in-line measurement), sampling location, statistical method, and acceptance criteria depend on the intended use of the data and process dynamics. The intended use of data may include detection of rapid changes such as disturbances, assessment of quality of a batch when real-time release testing (RTRT) (ICH Q8) is used, or analysis of process trends or drifts. Further important considerations are the avoidance of measurement interference with the process as well as the impact of physical sampling on the material stream potentially affecting state of control. Assessment of risks associated with data gaps (e.g., PAT recalibration, refill of a feeding system, failure of system components) should inform whether contingency methods are warranted. 3.1.6. Material Traceability and Diversion CM processes may include periods when non-conforming materials are produced, for example, during system start-up and shutdown or when disturbances are not appropriately managed and mitigated. The ability to detect and divert potential non-conforming material from the product stream during production is an important characteristic of CM and should be considered when developing the control strategy. Understanding the RTD and process dynamics of individual unit operations and integrated systems over planned operating conditions enables tracking of the distribution of materials over time. This allows input materials to be traced throughout production. Material traceability, understanding how disturbances affect material quality, and the use of appropriate measurements (e.g., PAT) allow for real-time determination of when to start and stop material collection or diversion. The amount of material diverted can be influenced by several factors, such as process dynamics, RTD, control strategy, severity (e.g., magnitude, duration, frequency) of the disturbances, and location of the sampling and diversion points. Additionally, it is important that the diversion strategy accounts for the impact on material flow and process dynamics when material is diverted. Criteria should be established to trigger the start and end of the diversion period and restart of product collection. 3.1.7. Process Models Process models can be used for development of a CM process or as part of a control strategy for commercial production, including the diversion strategy. Process models may also be used to predict quality attributes in real time, enabling timely process adjustments to maintain a state of control. During development, process models can support the establishment of a design space by explaining how inputs (e.g., process parameters, material attributes) and outputs (e.g., product quality attributes) are related. Process models can enhance process understanding and reduce the number of experimental studies. For general considerations regarding models (including implications of model impact to validation requirements), refer to Points to Consider: ICH-Endorsed Guide for ICH Q8/Q9/Q10 Implementation. For CM applications, additional considerations are discussed below. • A process model is specific to system design and configuration and relevant material properties. ICH Q13 Guideline • Model development requires an understanding of the underlying model assumptions (e.g., plug flow versus mixed flow systems) and when these assumptions remain valid. Risk assessments, sound scientific rationales, and relevant data inform the selection of model inputs and model formulation. It is important to determine the relevant inputs that affect the model performance, based on appropriate approaches such as sensitivity analysis. • Model performance depends on factors such as mathematical constructs and the quality of model inputs (e.g., noise, variability of data). When setting acceptance criteria for model performance, the model’s intended use and the statistical approaches that account for uncertainty in the experimental measurement and model prediction should be considered. • Model validation assesses the fitness of the model for its intended use based on predetermined acceptance criteria using statistically sound approaches. Model validation activities are primarily concerned with demonstrating the appropriateness of the underlying model assumptions and the degree to which sensitivity and uncertainty of the model and the reference methods are understood. • During commercial manufacture, model maintenance and monitoring of model performance should occur on a routine and ongoing basis considering variability that could impact the model and/or when a process change (e.g., input material, process parameter change) is implemented. Effective and efficient lifecycle management of models is enabled by risk assessment of the impact of a model change (e.g., optimisation of model performance, change of the model’s intended use, change of underlying model assumptions), considering the scope of model development and model validation criteria. Depending on the extent of a change and its impact on model performance, a model may need to be redeveloped and validated. 3.2. Changes in Production Output Several approaches to changing production output are discussed below; other approaches are also possible. For already approved products manufactured using a CM process, it is important to justify the selected approach, assess risk and understand its impact on the overall control strategy and process performance, and as needed, update the control strategy to ensure risk control. Some changes may require process modification and process validation. • Change in run time with no change to mass flow rates and equipment: Issues not observed over shorter run times may become visible as run time increases. Additional risks and constraints should be considered and may include, for example, process drift, increased equipment temperatures, material build-up, exceeding the performance limit of components (e.g., validated in vitro cell age, resin cycle number), material degradation, membrane or sensor fouling, and microbial contamination. Decreasing production output (below the longest run time previously validated) generally would not imply additional risks, given the same equipment, process and control strategy are used. • Increase mass flow rates with no change to overall run time and equipment: The risks associated with this approach may impact output material quality and are related to changes in process dynamics and system capability to handle increased mass flow rates. Therefore, ICH Q13 Guideline this approach may require re-evaluation and modification of the control strategy, including process parameters and controls, material traceability, RTD, sampling, and diversion strategies to reduce risk. • Increase output through duplication of equipment (i.e., scale-out): Considerations for two commonly used scale-out approaches are provided below. o Replication of production lines (like-for-like): Replicating the integrated CM production line (i.e., same equipment and setup as the original CM system) can be used to increase production output. The replicate production lines follow the same control strategy. o Parallel unit operations on the same production line: When only some unit operations are replicated on the same line, risks are associated with maintaining control across parallel unit operations. Aspects to consider are maintenance of uniform flow distribution among the parallel operations, synchronisation and re- integration of parallel flow streams, changes to process dynamics, increasing the rate of other unit operations to handle the increased capacity, and material traceability. • Scale-up by increasing equipment size/capacity: Depending on the process and equipment design, increasing production by increasing equipment size may be possible. General principles of equipment scale-up apply, as in the case of batch manufacturing. As elements such as RTD, process dynamics, and system integration may change, various aspects of the control strategy may be impacted. The risks of scale-up and applicability of the original control strategy should be assessed at the new scale and the control strategy should be modified where needed. 3.3. Continuous Process Verification In CM, frequent process monitoring and control can be achieved through use of process parameters, PAT tools such as in-line/online/at-line monitoring and control, soft sensors, and process models. These tools allow real-time data collection for parameters relevant to process dynamics and material quality, and hence ensure the state of control for every batch. Additionally, since CM can facilitate changes to production output without increasing equipment size, there is an opportunity to generate development knowledge at the same scale intended for commercial manufacturing. These tools, together with the system design and the control strategy, facilitate early execution of process validation activities and the adoption of continuous process verification (ICH Q8) as an alternative approach to process validation. 4. REGULATORY CONSIDERATIONS The dossier for a CM process should be in accordance with ICH M4Q. Some CM-specific considerations are provided below. ICH Q13 Guideline 4.1. Description of Manufacturing Process and Process Controls In line with ICH M4Q, a sequential narrative description of the manufacturing process and process controls should be included in sections 3.2.S.2.2 and 3.2.P.3.3 of the Common Technical Document (CTD) and supported by pharmaceutical development data provided in CTD sections 3.2.S.2.6 or 3.2.P.2. In the case of CM, the information provided in sections 3.2.S.2.2 and 3.2.P.3.3 should be supplemented by the following, when applicable: • A summary of start-up, shutdown, pause and restart procedures, as applicable, to describe how the integrated CM process functions • The strategy for material collection and diversion including the criteria that should be met for product collection during routine manufacturing • Process parameters related to continuous flow (e.g., mass flow rate(s) or flow rate range) • When appropriate (e.g., movement of solid materials), a description of how the material is transported from one piece of equipment to another • A flow diagram with the following aspects identified, when applicable: o Points of material entry into the process and material exit from the process (including material diversion and collection points) o Sequence of unit operations, including any surge lines or tanks o Direction of material movement through each process step o Clear indication of the continuous and batch process steps o Critical steps and location points at which process controls, intermediate tests, or final product controls are conducted (e.g., PAT measurement, feedforward or feedback process control) • A suitably detailed description of any aspects of equipment design, configuration and system integration that were shown during development to be critical to process control or to impact product quality 4.2. Control Strategy The control strategy of a CM process is designed to ensure that output materials made over time are of the desired quality. The control strategy should consider the elements discussed in Section 3 of this guideline. The dossier should describe the relevant controls and operational aspects (e.g., material diversion) used during manufacturing. Some aspects of the control strategy are discussed below. ICH Q13 Guideline • Input material attributes: Impact of input material attributes and their variability (e.g., inter-batch, different suppliers) on continuous processing and product quality should be assessed and proposed material attribute acceptable ranges should be justified when establishing the material specification. For input materials for which pharmacopoeial requirements exist, characterisation and control may extend beyond those requirements. • Process monitoring and control: An appropriate description should be provided in the dossier to show a robust approach to process monitoring and maintaining a state of control. How the control system uses process parameters, in-process material attribute measurements, etc., to make process- and quality-related decisions (e.g., to pause the process or divert material) should be described. Other important aspects should be defined, such as the sampling strategy (e.g., location, sample size, frequency, statistical approach and criteria, and their relevance to the intended use), summary of the models if used (e.g., type of model used, strategies for model evaluation and performance monitoring), and the use of data in making in-process control decisions (e.g., to trigger material diversion). The data analysis method used should appropriately detect the disturbances or variability in the CM process. For example, when data averaging is used, averaging across appropriate time intervals should be considered rather than data averaging across the entire CM run time. The time intervals should consider the relevancy of PAT measurement frequency to the RTD and process dynamics (i.e., process response time). Therefore, statistical sampling plans and data analysis should be described and justified. • System operation: Procedures should be established and maintained on site for managing system start-up, shutdown, and pauses and for handling disturbances (see Annex V). Relevant approaches for these operations (e.g., handling disturbances) should also be described at an adequate level of detail in the dossier. The disposition of material impacted by transient and pause events should be justified, considering potential risks to output material quality (e.g., the impact of a disturbance as it propagates downstream). • Material diversion and collection: The material diversion and collection strategy should be summarised and justified in the dossier. The strategy described should include the criteria for triggering material diversion, the basis for determining the extent of diverted materials, the conditions for resuming material collection, etc. Factors such as sampling frequency, RTD, and amplitude, duration and propagation of disturbances should be considered in developing the diversion strategy. The extent of diverted material should appropriately incorporate justified safety margins, considering the uncertainty of RTD and other measurements. Procedures for managing material collection, diversion, and disposition (e.g., quarantine, offline testing, investigations) do not need to be included in the dossier but should be maintained within the pharmaceutical quality system (PQS) (ICH Q10). • RTRT: RTRT as described in ICH Q8 can be applied to an output material quality attribute(s). RTRT is not a regulatory requirement for CM implementation. When RTRT is proposed, the associated reference test method should be described. Development of the data collection approach for RTRT implementation should include a risk assessment of ICH Q13 Guideline how any lapses in data collection (e.g., recalibrating a near infrared (NIR) probe) may affect decisions relating to product quality. The proposed control strategy should include alternative or additional quality controls to mitigate any risks posed by data lapses. If the results from RTRT fail or are trending towards failure, appropriate investigations should be conducted. Refer to Points to Consider: ICH-Endorsed Guide for ICH Q8/Q9/Q10 Implementation for discussion of models used as surrogates for traditional release testing methods. • Equipment and system integration: Aspects of equipment design and system integration that are shown to be critical to output material quality and its control should be described and justified in the context of the overall control strategy. A summary of the control strategy should be provided in CTD section 3.2.S.2.6 or 3.2.P.2.3 with links or references to the CTD sections that contain the detailed information to enable the understanding and evaluation of the manufacturing process and how it is controlled. 4.3. Batch Description and Batch Size The approach to define batch size (see examples in Section 2.2) and the proposed commercial batch size or range should be described in the dossier. If a range is proposed, it should be justified, and the approach for achieving the range should be described (see Section 2.2). Changes in batch size within the approved batch size range can be managed within the PQS. Any post-approval change beyond the approved range should be supported by data (Section 3.2) and appropriately managed (i.e., prior approval or notification). A suitable quantitative metric with acceptance criteria should be defined within the PQS to establish batch-to-batch consistency and system robustness. For example, when a batch size is defined by the amount of collected material, the amount of diverted materials relative to that of collected materials for each batch should be considered. The actual intended size of a given batch should be defined before manufacturing begins. 4.4. Process Models The level of detail provided in the dossier regarding model development, validation, and maintenance over the lifecycle should be commensurate with the model type and impact category. The process model should be specific for the defined system (e.g., equipment, layout, connections). Information to support models used as part of commercial manufacturing should be available during site inspection and maintained at or be accessible to the manufacturing site. Refer to Points to Consider: ICH-Endorsed Guide for ICH Q8/Q9/Q10 Implementation for regulatory expectations on process models. 4.5. Drug Substance and Drug Product Stability Regulatory expectations for the stability data package generally do not differ between CM and batch manufacturing modes (refer to ICH Q1A, ICH Q5C). Batches used to generate primary stability data should be manufactured using a manufacturing process and equipment representative ICH Q13 Guideline of the commercial process. Primary stability batches should incorporate the variability described in the ICH stability guidelines (e.g., different drug substance batches). Additionally, for chemical drug substances or drug products: • Stability batches could be obtained with a single start-up/shutdown sequence provided the aforementioned variability is incorporated into the batches (e.g., by introducing different batches of drug substances in a sequential manner). • Stability batches may be produced from shorter manufacturing runs, provided that (1) the control strategy, mass flow rate(s), and equipment used to generate stability batches are representative of the commercial process, and (2) it is demonstrated that a state of control is established and maintained when the process operates over the longer commercial run times. The concept of pilot scale batch for stability studies (e.g., at a minimum, one-tenth of a full production scale), as defined in other guidelines (e.g., ICH Q1A), may not be necessarily applicable in this scenario. • If modes of increasing production output discussed in Section 3.2 other than increasing run time are being used (e.g., increasing equipment size), applicants should justify their approach for defining primary stability batches. Applicants are encouraged to discuss their scale-up and primary stability batches approach with regulatory authorities. 4.6. Conversion of a Batch Process to CM Changing the manufacturing mode from batch to continuous necessitates the development of an appropriate control strategy, considering factors identified in Section 3. The output materials from the batch and continuous processes should have comparable quality. A science and risk-based approach should be used for establishing product comparability and assessing the need for additional bioequivalence, non-clinical and/or clinical studies, and stability data. Additional details regarding how to establish product comparability for therapeutic proteins can be found in ICH Q5E. Manufacturers should seek regulatory approval before implementing a conversion of an approved batch process to a CM process. Manufacturers can seek advice from the regulatory authority to gain clarification on the regulatory expectations and acceptability of their strategy and data package for the proposed changes (e.g., when potential changes in formulation are necessary to enable conversion to CM and the impact of these changes on product registration). 4.7. Process Validation The requirements for process validation as established by region are similar for CM and batch manufacturing processes. Approaches such as traditional process validation that uses a fixed number of validation batches or continuous process verification can be used. When continuous process verification is used, the CM system performance and output material quality is continuously monitored, such that the real-time data collected demonstrate the maintenance of a state of control and production of output material with the desired quality for the run time duration. The use of continuous process verification should be justified based on the ICH Q13 Guideline product and process understanding, system design, and overall control strategy. This justification should be provided in the dossier (see Table 1 below). When a continuous process verification approach is used to support initial product launch, applicants should justify the appropriateness of the validation activities to provide confidence in the commercial manufacturing process. 4.8. Pharmaceutical Quality System PQS expectations are the same for batch and CM processes and should follow pertinent ICH guidelines. One important operational aspect of CM is that non-conforming materials can be diverted from the rest of the batch when material traceability, process monitoring, and material diversion strategies are well established. Procedures for material diversion, when required, should be established under the PQS (see Section 4.2). An overarching plan or decision tree that describes how disturbances are managed for various types of material diversion should be maintained under the PQS. Diverted materials resulting from planned events (e.g., system start-up and shutdown) generally do not require investigation when the events meet established process performance criteria. Examples of approaches for managing disturbances are provided in Annex V. As described therein, when unexpected and/or frequent disturbances occur, appropriate investigation, root cause analysis, and corrective action and preventive action (CAPA) should be instituted. 4.9. Lifecycle Management The principles and approaches described in ICH Q12 are applicable to the lifecycle management of CM. 4.10. Submission of CM-Specific Information in the CTD The dossier should include information as outlined in ICH M4Q. Additional elements relevant to CM should also be provided in the dossier when applicable. Examples of these elements are listed in Table 1. In the case of integrated drug substance and drug product CM processes, some information and data, such as an integrated flow diagram, may be presented in CTD section 3.2.P with a cross reference in 3.2.S (see Annex IV for additional details). Table 1: Recommended CM-Related Information in the CTD CTD section Information and Data 3.2.S.2.6 3.2.P.2.3 Manufacturing Process Development • Summary of the overall process development • Summary and justification of the control strategy, with links or references to the CTD sections that contain comprehensive information on the control strategy elements, for example: o Strategy for system start-up, shutdown and pause o RTD and material traceability information o Disturbance management (e.g., material diversion and collection strategy) o Sampling strategy, including sampling frequency ICH Q13 Guideline o Equipment design and system integration aspects that are shown to be critical to output material quality o Process controls such as feedforward and feedback process control based on a measured attribute, if used o Development and justification of models# where used in the control strategy (e.g., process model used for feedforward control, model associated with a PAT analytical method used for in-process testing and/or real-time release) o Justification for range of batch sizes, where claimed 3.2.S.2.2 3.2.P.3.2 Batch Definition • Batch size or range, and approach to achieving the intended batch size or range 3.2.S.2.2 3.2.P.3.3 Description of Manufacturing Process and Process Controls • Narrative description of the commercial manufacturing process and flow diagram as described in ICH M4Q, clearly indicating which portion of the manufacturing process is continuous • Examples of CM-specific aspects of the commercial manufacturing process to be described are: o Equipment design and system integration aspects when critical to the output material quality o CM-related process parameters, controls and criteria (e.g., input rates/mass flow rates, relevant feeder operating ranges), and location points at which process controls or testing is conducted o Location of active process controls if used o Criteria for product collection, including strategy for diversion 3.2.S.2.4 3.2.P.3.4 Controls of Critical Steps and Intermediates • Critical process parameters • In-process testing (e.g., sampling frequency, sample size, analytical method) • Relevant information, parameters, and criteria associated with ensuring correct application of process models used as part of the control strategy# including contingency plan when the model is not available • Relevant information on active process controls, when applicable (e.g., limits of acceptability for controls that ensure monitored ICH Q13 Guideline critical process parameters and critical quality attributes stay within desired ranges) 3.2.S.4 3.2.P.5 Control of Drug Substance or Drug Product • When models are associated with the analytical procedures for release testing of the drug substance or the drug product (e.g., NIR model, dissolution model): o Summary and justification of the model and the sampling strategy o Contingency testing and monitoring plans instituted for when the model is not available (e.g., when gaps in PAT data occur or in case of PAT equipment failure) o Analytical model validation information 3.2.R Regional Information • Validation data for high impact process models, if used. • Continuous process verification scheme, if applicable. # The purpose of a model may vary (e.g., testing the quality of in-process material, drug substance intermediate, drug substance or drug product, real-time release testing, process control). Not all categories are covered in this table; information relating to the models should be submitted in the appropriate CTD sections identified in ICH M4Q guideline for these categories. For example: • Models used for drug substance release testing in 3.2.S.4; • Models used for in-process testing in 3.2.S.2.4 or 3.2.P.3.4; • Model used for both in-process testing and real-time release testing in relevant 3.2.S.4 or 3.2.P.5 sections, and incorporated by reference into the applicable Control of Critical Steps and Intermediates section; • Models used only for process development in 3.2.S.2.6 and 3.2.P.2.3. ICH Q13 Guideline 5. GLOSSARY Active Process Controls: A system consisting of hardware and software architecture, mechanisms, and algorithms that automatically adjust a process to maintain the process output within a desired range. Examples include feedforward and feedback process controls. Disturbances: Unplanned changes to process inputs beyond normal operating range or conditions (e.g., process parameter, material property, equipment condition, or environment) that are introduced into a system. Diversion: Procedure in which materials are isolated and separated from the product stream in the manufacturing process. Material Traceability: The ability to track materials throughout the manufacturing process. Model Maintenance: A set of planned activities over the product lifecycle to monitor and sustain the model’s performance to continually ensure its suitability for the intended and approved purpose. Multivariate Statistical Process Control: The application of multivariate statistical techniques to analyse complex process data with potentially correlated variables. (Ph. Eur.) Process Dynamics: The response of a manufacturing process to changing inputs or conditions or transient events. Residence Time Distribution (RTD): A measure of the range of residence times experienced by material passing through a specific process environment/vessel/unit operation. Run Time: The time interval used to produce a quantity of output material. Soft Sensors: A model that is used in lieu of physical measurement to estimate a variable or attribute (e.g., a quality attribute of material) based on measured data (e.g., process data). The model development, including selection of such data variables, is driven by comprehensive product and process understanding. ICH Q13 Guideline Steady State: A stable condition that does not change over time. System: A manufacturing architecture that, in the context of CM, consists of individual pieces of equipment, their connections to one another, monitoring and control systems, and spatial layout. Transient Events: A temporary condition in which a process goes through a dynamic change. This change may be due to a disturbance or an intentional alteration in the selected operating conditions (e.g., start-up, shutdown, changes from one operating condition to another). Unit Operation: A basic step in a process. Unit operations involve a physical, chemical or biological transformation such as: reaction, crystallisation, filtration, blending, granulation, tableting, cell culture, purification or virus inactivation. 6. REFERENCES ICH M4Q: The Common Technical Document for The Registration of Pharmaceuticals for Human Use: Quality ICH Q1A: Stability Testing of New Drug Substances and Products ICH Q5C: Quality of Biotechnological Products: Stability Testing of Biotechnological/ Biological Products ICH Q5E: Comparability of Biotechnological/Biological Products Subject to Changes in Their Manufacturing Process ICH Q6A: Specifications: Test Procedures and Acceptance Criteria for New Drug Substances and New Drug Products: Chemical Substances ICH Q7: Good Manufacturing Practice Guide for Active Pharmaceutical Ingredients ICH Q8: Pharmaceutical Development ICH Q9: Quality Risk Management ICH Q10: Pharmaceutical Quality System ICH Q13 Guideline ICH Q11: Development and Manufacture of Drug Substances (Chemical Entities and Biotechnological/Biological Entities) ICH Q12: Technical and Regulatory Considerations for Pharmaceutical Product Lifecycle Management Ph. Eur.: European Pharmacopoeia Points to Consider: ICH-Endorsed Guide for ICH Q8/Q9/Q10 Implementation ICH Q13 Guideline PART II: ANNEXES ANNEX I: CONTINUOUS MANUFACTURING OF DRUG SUBSTANCES (CHEMICAL ENTITIES) 1. INTRODUCTION AND EXAMPLE SYSTEM OVERVIEW This annex exemplifies one approach to implement CM of drug substances for chemical entities based on the scientific principles described in the main guideline. The examples and approaches in this annex are illustrative, and alternative approaches can be used. *[Figure 1 illustrates a drug substance manufacturing process containing both continuous and batch]* operations. It is not intended to represent a regulatory flow diagram. The continuous process segment consists of unit operations that can be characterised as having two plug-flow reactors (PFRs), two liquid phase extraction operations, continuous crystallisation, and two agitated filter dryers. Manufacture of Intermediate 2 is performed in batch mode, as is final processing including milling and packaging. This annex focuses on the continuous elements of this process. *[Figure 1: Example of a drug substance CM system for chemical entities]* ICH Q13 Guideline 2. CONTROL STRATEGY AND OTHER TECHNICAL CONSIDERATIONS The CM system and its control strategy were designed to control parameters that impact the manufacture and quality of the drug substance, including impurity profile and physicochemical properties. The overall control strategy was developed in accordance with the main guideline and ICH Q7–Q11. 2.1. Equipment Design and Integration Within the continuous process segment in Figure 1, the following processes occur: • Reaction 1: Starting materials 1 and 2 are coupled in a PFR to produce Intermediate 1. Diversion Point D1 is located after the PFR to permit material diversion when PFR conditions are outside predefined acceptance criteria. The reaction is quenched as an integrated operation after the PFR, and unwanted by-products are removed by liquid-liquid extraction. The resultant solution (Intermediate 1) is used as an input for the second reaction without isolation. • Reaction 2: Intermediate 1 and Intermediate 2 (prepared upstream through separate batch unit operations) are coupled in a second PFR to form the crude drug substance. The online PAT near the reactor exit (T1) monitors conversion of Intermediate 1 to the crude drug substance. Diversion Point D2 located after PAT is used to divert non-conforming material. • Drug Substance Isolation: The crude drug substance is purified by liquid-liquid extraction and continuous two-stage crystallisation. Distillation prior to crystallisation provides desired concentration of the crude drug substance solution. Diversion Point D3 allows for material diversion at the crystalliser. The crystal slurry is filtered using two agitated filter dryers operating in an alternating fashion to enable continuous operation. The isolated drug substance is then milled using batch operations to achieve the desired particle size distribution prior to packaging. Two surge points (each containing multiple surge tanks) are used: one before Reaction 2 and another before continuous crystallisation. These are important components of the system design and control strategy, as they improve process robustness and mitigate temporary differences in mass flow rates by decoupling upstream and downstream operations. The design of the overall system and each unit operation, along with the control strategy, optimise material quality. For example, PFR design elements (i.e., dimension and configuration) allow control of temperature, heat and mass transfer rates, and reaction time. These parameters were shown during development to be important to the drug substance impurity profile. 2.2. Process Control and Monitoring Holistic controls used across Reactions 1 and 2 ensure consistent operations and quality of the resulting crude drug substance. The stoichiometry of Reaction 1 is controlled via control of concentrations and flow rates of the feeds. Conversion of starting materials to Intermediate 1 with minimal impurity formation is ensured through control of the reaction temperature and flowrate (i.e., reaction time). Reaction 2 is controlled through feedback control of the addition rate of Intermediate 2 based on the PAT measurement of residual Intermediate 1 levels. This ensures ICH Q13 Guideline correct stoichiometry for that reaction and minimises the impact of variability of the Intermediate 1 feed solution on drug substance purity. The PAT also measures levels of crude drug substance and impurities, which confirm successful operation of all preceding steps and consistent product quality. Liquid/Liquid extraction ensures appropriate purity control after Reaction 2. RTD was used to develop a suitable strategy for disturbance detection, corrective actions, and material diversion. RTD characterisation was based on mathematical modeling of all unit operations and surge points across the entire CM process over planned mass flow rates. The RTD was then confirmed through experimental tracer studies for appropriate segments of the commercial equipment. Decisions for triggering material diversion are based on comparing process parameters and PAT measurements to predefined acceptance criteria with timing and duration of diversion informed by the RTD. Importantly, the RTD is also used for material traceability purposes. Understanding of process dynamics and its impact on quality attributes of material produced throughout the entire process was also used to guide start-up and shutdown strategies. For example, during start-up of Reactions 1 and 2, a small amount of Intermediate 1 or crude drug substance is diverted at Diversion Points 1 or 2, respectively, to allow those materials to reach the target concentrations before processing into subsequent operations. The criteria for diversion were established based on time considering the RTD. This approach was supported by development studies and appropriately confirmed in commercial process equipment. PAT monitoring after Reaction 2 provides additional verification that appropriate criteria have been met during start-up. Collection of material proceeds to the end of the process as subsequently described. Sampling and process measurement needs were evaluated, considering relevant factors such as residence times (i.e., surge points, process dynamics, and the type and purpose of the measurement). The measurement frequency of the PAT at Reaction 2 enables detection of certain disturbances, informs process adjustments, and ensures timely diversion of material based on predefined criteria. The criteria for material diversion are based on the magnitude and duration of the disturbance, an understanding of RTD and process dynamics of downstream unit operations and surge points, and the impurity purging capability of the crystallisation operation. As a result of this control strategy, all crude drug substance solution that enters continuous crystallisation meets acceptable quality criteria and can be processed through the crystalliser. Appropriate controls and monitoring requirements for the continuous crystallisation were extensively investigated during development in similar, but smaller scale equipment and appropriately verified using commercial equipment. Process development included spiking studies using impurity-enriched feed solutions and intentional perturbations in process parameters (i.e., feed flow rates, their ratios, and temperatures). An evaluation of the encrusted solids in the crystalliser over extended run times demonstrated the solids were the same form and purity as the free-flowing drug substance slurry. The set of process parameters and ranges identified by these studies were appropriately scaled up. Implementation of these controls along with post- crystallisation material tests (e.g., crystal form, purity) ensure consistent quality of the resulting drug substance throughout continuous crystallisation and subsequent filtration. ICH Q13 Guideline The resulting material is milled using a batch operation to provide a drug substance of the appropriate particle size for use in drug product manufacturing. Procedures were developed to allow diversion of material at Diversion Point D3 in the event desired process conditions or material attributes are not met. Diversion of the drug substance from the crystalliser was found to be unnecessary either during start-up or shutdown. 2.3. Consideration of Other Controls Process robustness and performance over time are important considerations. A risk assessment was performed to ensure that adequate controls are in place to support the proposed run time (which can be up to several months). It identified a number of considerations and corresponding controls/measures. Examples are summarised in Table 2. Table 2: Examples of other controls for consideration Consideration Controls/Measures Cleaning and fouling potential • Establishment of a risk-based cleaning strategy, including understanding of the impact of build-up on drug substance quality • Additional monitoring to assess fouling and cleanliness (e.g., pressure sensors at the discharge of feed pumps, periodic visual checks for the continuous crystalliser) • Reduction of other risk factors (e.g., filtering feed streams to further reduce fouling risk) Stability of in- process materials • Hold times at key points in the process (e.g., feed streams; accumulated material at the surge points, reactors, and crystalliser) managed through batch record and process automation • Risk assessment of microbiological growth (i.e., negligible risk based on the nature of the process materials and conditions) Calibration and potential for changes/drift in instrumentation • Periodic checks at selected points (e.g., process parameter measurements for the PFR, system suitability for the PAT analyser) • Dual sensors at selected locations (e.g., temperature probes for the PFR) so that appropriate corrective actions can be taken Equipment maintenance • Maintenance requirements for target run time • Use of redundant equipment (e.g., backup pumps) at key locations Additionally, specifications for input materials were evaluated during process development. There were no differences between batch and continuous processing for this example. Collectively, the process understanding developed along with implementation of the various controls described provide a robust and reliable control strategy. This ensures consistent quality of the resulting drug substance including the impurity profile, physicochemical properties, and ability of the system to identify and appropriately react to unexpected events. 2.4. Process Validation The combination of process controls, online PAT measurements, comprehensive monitoring of process parameters and material attributes, and end-product testing results in a data-rich environment for this process. Together with system understanding generated during development, ICH Q13 Guideline this enabled the use of a traditional process validation for commercial product launch and continuous process verification to validate process changes over the product lifecycle. A range of batch sizes was initially established based on material demands and the quantities of material necessary to match input needs of the final batch unit operations. The process was validated using a fixed number of batches. A single planned start-up and shutdown of the commercial CM system was used to manufacture the process validation batches. This approach was supported by the totality of evidence demonstrating the start-up and shutdown capabilities of the system. This included development work on smaller equipment (with appropriate technical justification for being representative), commercial equipment and system qualification data, results of a pre-validation demonstration run, and extensive process monitoring of the CM system that can verify success of each start-up and shutdown in real time. Subsequently, a continuous process verification approach was adopted after product approval to validate increases in batch size with extension of run time. The batch size increase was possible without impact to the equipment scale for downstream batch operations. This approach used a risk assessment for the longer run time, which concluded that process performance and material quality would not be impacted. Under the continuous process verification approach, data generated during the manufacture of each batch was used to support successful validation of that batch with the extended run time. This included information such as system performance monitoring and data logs, along with other controls that ensure material quality with appropriate detection and corrective action. Additionally, appropriate regulatory actions were taken to communicate this batch size increase with run time change and use of the continuous process verification approach. 3. REGULATORY CONSIDERATIONS Refer to Section 4 of the main guideline. In consideration of the specific CM process design, additional elements may need to be included in a dossier. For instance, in this example, the influence of surge points on the material diversion and collection strategy, including the fate of materials, was described. ICH Q13 Guideline ANNEX II: CONTINUOUS MANUFACTURING OF DRUG PRODUCTS (CHEMICAL ENTITIES) 1. INTRODUCTION AND EXAMPLE SYSTEM OVERVIEW This annex exemplifies one approach to implement CM for a tablet drug product based on the scientific principles described in the main guideline. The examples and approaches in this annex are illustrative, and alternative approaches can be used. Specific considerations relating to the implementation of a continuous direct compression process for a chemical entity are presented. *[Figure 2 illustrates a continuous direct compression process that consists of continuous feeding,]* blending, and tablet compression unit operations, with batch mode film coating. It is not intended to represent a regulatory flow diagram. *[Figure 2: Example of a tablet drug product CM system]* A PAT tool using an NIR method monitors blend uniformity and triggers tablet diversion. Run time at a predefined mass flow rate is used to define the batch size range; in this case, the overall marketing demand requires batch sizes between 360 and 1080 kg of the drug product. 2. CONTROL STRATEGY AND OTHER TECHNICAL CONSIDERATIONS The CM system and its control strategy were designed to mitigate the impact of disturbances to ensure output material quality. The overall control strategy was developed in accordance with the main guideline and ICH Q8–Q10. 2.1. Material Characterisation and Control ICH Q13 Guideline During process design and development, a quality-by-design approach was adopted that identified equipment and process parameters critical to control of the process. Furthermore, the relationships between material quality attributes and their impact on unit operations (particularly the loss-in- weight feeders (LIWFs) and blender) and product critical quality attributes (CQAs) were evaluated. Bulk density of the primary excipient and particle size distribution (PSD) of the drug substance were identified as critical to blend and content uniformity. A defined bulk density range and three-tier (d10, d50, d90) PSD specification were implemented for the excipient and drug substance, respectively. 2.2. Equipment Design and Integration Unit operations and system components (e.g., NIR probe) were designed or selected to mitigate the impact of disturbances on final product quality. The overall design principle is, where possible, to use gravity to move material. During system integration, the material flow was coordinated across all unit operations to avoid material accumulation or emptying. System mass balance was obtained through understanding of material flow (i.e., RTD) at the intended operating conditions of each unit operation. The impact of equipment design and operation on process dynamics was characterised by the RTD of individual unit operations, as well as the RTD of process segments between individual unit operations and the diversion point. The RTDs were determined by replacing the drug substance in the formulation with a tracer that has highly similar flow properties to those of the drug substance. The following aspects of equipment design and integration were emphasised: • LIWF: Feeder mass flow rates and their variability were characterised. LIWFs are controlled to deliver the theoretical amount of each input material per the formulation; it was demonstrated that the risks of minor variations to product composition were mitigated by blender mixing capability. Feeder mass flow rates were evaluated using design of experiment (DOE) studies and the proven acceptable ranges of target flow rates were defined. Modelling and statistical approaches were used to help determine the limits for the magnitude and duration of disturbances in mass flow rates, for which material diversion, operator investigation, or process stop are needed. These limits were visualized (e.g., funnel plots) to aid understanding. LIWFs operate in gravimetric mode unless they are refilling (volumetric mode). Refill aspects (e.g., duration and mass of refill) were evaluated to minimise the impact on feeding. • Blender: A horizontal blender was selected for the CM system and the blender design was evaluated (e.g., paddle versus ribbon, number and orientation of paddles in the blender, rotation speed). It was determined that a paddle blender is critical to ensure desired blend uniformity. Rotation speed, number and orientation of the paddles were evaluated for their impact on blend uniformity over the ranges studied, and the corresponding design space for the blending process was defined. RTD characterisation provided information on the degree of forward and back mixing and disturbance propagation, and the RTD was used to define the material traceability and diversion strategy. • NIR probe: The NIR probe was placed in the tablet press feed frame. The chosen NIR equipment met the PAT application requirements (e.g., analysis speed, sampling method, ICH Q13 Guideline mass flow rate). Probe location and height are fixed; the impact of material build-up was evaluated and found not significant. The system intended for commercial production was used to generate data for the development, calibration, and validation of the NIR method. • Diversion point: The RTD between the NIR probe and the diversion point was characterised using a tracer. The material diversion strategy links LIWF and NIR limits to the RTD between the LIWF and NIR as well as the RTD between the probe and diversion point, respectively. • Coater: The mass in the coater corresponds to 1 hour of production. Coating was designed to be complete in 45 minutes; whilst coating, the next aliquot of tablet cores is filled into the tablet hopper. 2.3. Process Controls and Monitoring In this system, the LIWFs may introduce fast dynamic disturbances. These may also occur during changes in operating conditions (e.g., during start-up or process pauses). Therefore, monitoring and control of these events are important elements of the control strategy. The control strategy includes NIR measurements, in-process controls (e.g., individual and total flow rates), process parameters including critical process parameters (e.g., blender rotation speed), and active process controls (e.g., feedback control of tablet weight). The sampling strategy for monitoring and control reflects the observed process dynamics, therefore ensuring adequate detectability of all relevant disturbances. Together, these aspects enable proactive control of the system and ensure continuous operation in a state of control and accurate material diversion to waste based on the predefined criteria. Unique codes are assigned to predefined batch segments to ensure material traceability and identification of conforming and non-conforming materials. Start-up/restart, pause/stop, and shutdown strategies for this example are defined in Table 3. Table 3: Start-up/restart, pause/stop, and shutdown strategies Action Activity Start-up/Restart Material tracking and data collection begins; manufactured material is diverted until it meets the predefined acceptance criteria for material collection. Pause/Stop A process pause or stop is executed either manually or automatically, according to predefined criteria. Shutdown Material collection continues until manufactured material fails the predefined acceptance criteria, and then manufacturing ends. 2.4. Process Validation In this example, a continuous process verification approach was adopted, considering elements such as prior facility experience in implementing a similar CM process and control system (i.e., platform approach), availability of product-specific data arising from late-stage product development using the commercial equipment, the scale independence of the commercial process (i.e., batch size varies by run time), a comprehensive control strategy with high-frequency data collection, and the use of real-time data from every manufacturing run to further support continuous process verification. The control strategy provides real-time monitoring, trending, and ICH Q13 Guideline prediction analysis through the use of NIR measurements, LIWF data, and other data sources arising from monitoring process parameters (e.g., blender torque), thus providing a high degree of assurance of real-time CM system stability and performance and output material quality. The continuous process verification approach, coupled with appropriate regulatory action for reporting manufacturing changes, was used to validate run time extensions beyond current experience. 3. REGULATORY CONSIDERATIONS Refer to Section 4 of the main guideline. In consideration of the specific CM process design, additional elements may need to be included in a dossier. For instance, in this example, elements that can significantly impact process dynamics and homogeneity (e.g., design space, number of paddles and their orientation in the horizontal paddle blender) were described. ICH Q13 Guideline ANNEX III: CONTINUOUS MANUFACTURING OF DRUG SUBSTANCES (THERAPEUTIC PROTEINS) 1. INTRODUCTION AND EXAMPLE SYSTEM OVERVIEW Annex III supplements the main guideline by providing additional regulatory and scientific considerations that are relevant to CM processes for therapeutic protein drug substances and recombinant proteins used as intermediates for subsequent conjugation. It describes aspects that could be applied in fully or partially integrated CM systems. The discussion points and examples presented in the annex are provided for illustrative purposes and are not exhaustive. Alternative approaches can be used. *[Figure 3 illustrates a continuous manufacturing process for therapeutic proteins that consists of]* unit operations characterised by a bioreactor compatible with a perfusion culture system, continuous capture chromatography, virus inactivation, and polishing purification chromatography columns, virus filtration, and buffer exchange and concentration through tangential flow filtration. It is not intended to represent a regulatory flow diagram. This process integrates a perfusion cell culture with continuous downstream chromatography and other purification steps to continuously capture and purify the target protein. Each individual unit operation is integrated with adjacent unit operations or with a surge line or tank that connects unit operations. Diversion point D1 and PAT (T1) are located after chromatography (Chrom) #1. Using a surge line or tank allows continuous operations to accommodate differences in mass flow rates or process dynamics. Other examples of CM systems may use integrated unit operations for selected steps. In CM processes, a single thaw of one or multiple vials from the same cell bank may result in either a single harvest or multiple harvests. The number or range of cell bank vials used to produce the specified number of drug substance batches should be defined. The cell bank vials used should be traceable to the output drug substance batches. ICH Q13 Guideline *[Figure 3: Example of a drug substance CM system for therapeutic proteins]* 2. CONTROL STRATEGY 2.1. Adventitious Agent Control In general, all principles used to ensure safety in batch manufacturing are applicable to CM. Safety is demonstrated by a threefold approach based on the principles outlined in ICH Q5A. Control of adventitious agents (e.g., bacteria, viruses, fungi, mycoplasma) should be based on a risk assessment of all potential sources of contamination (e.g., starting and raw materials, manufacturing operations), the ability of the process to remove and inactivate adventitious agents, and the testing capability to ensure the absence of adventitious agents. Based on this assessment, a strategy should be developed to include the type and frequency of adventitious agent testing undertaken to demonstrate that the process remains free of contamination during cell culture and other downstream steps. An aspect unique to CM is extended cell culture duration and continuous processing of harvested cell culture material to obtain drug substances. This means that design measures should be in place to demonstrate the acceptability of all cell culture material used to generate a given drug substance batch. New technologies for real-time decision making, such as rapid testing for adventitious agents, may be used to mitigate the impact of contamination events by earlier detection and appropriate responses during continuous operation. 2.2. Equipment Design and System Integration The integrity of single-use equipment during use should be ensured to prevent contamination. Single-use connections (e.g., tube welds, connectors) and components may experience long ICH Q13 Guideline durations or high change-out frequencies and should be evaluated as potential contamination risks. Filtration steps in CM may be subject to longer filtration periods and potentially increased throughput per unit area or a greater number of filter changes than those under batch manufacturing. Given these factors, a control strategy and a clearly defined scheme should be put in place to allow for filter changes and pre- and post-use integrity testing, as appropriate, without interrupting the process. In the event of a filter failure, a clear strategy for material diversion and refiltration (reprocessing) should be defined. The CM system should contain appropriate sampling locations based on risk assessment to enable detection of contamination, while avoiding unnecessary contamination risk introduced through the sampling procedure. The sampling locations and frequency may be adjusted based on improved product and process understanding. Integrated systems may use surge tanks for flow rate adjustments or other purposes between processing steps. When surge tanks are used, the relevant RTD, uniformity and microbial risks to the product in these surge tanks should be evaluated and defined in advance. 2.3. Process Monitoring and Real-Time Release Testing CM lends itself to various monitoring schemes with different levels of automation. Examples include in-line sensors placed directly in a process vessel or flowing material stream and online analysers that conduct automatic sampling. Regardless of the approach used, appropriate monitoring at suitable stages of the CM process enables timely data analysis to ensure operations are in a state of control. In certain cases, relevant process parameters may be adjusted to ensure the quality of in-process or output materials. Enhancing in-line/online PAT capabilities and development of automation systems for process monitoring enable a continuous monitoring scheme in support of a release testing strategy that may include RTRT for some quality attributes. For example, drug substance in-line release tests for pH, osmolality, protein concentration and online release tests for purity, charge heterogeneity, aggregation, and low-molecular weight impurities can be performed at specific points in the drug substance manufacturing process shown to be critical for control of the product quality attributes. An in-process test that is demonstrated to be representative of a release test performed on the output material may be used as a surrogate for a traditional release testing method. Conventional offline testing for product release is necessary for quality attributes for which analytical technologies are not available for online or in-line measurements (e.g., potency). Likewise, conventional tests for monitoring and control (e.g., microbiological analytical methods and other tests that require long processing times) might also be needed. 3. PROCESS VALIDATION 3.1. Approaches to Process Validation Process validation approaches used for batch processes are also applicable to CM processes with additional considerations for equipment performance over extended run times, integration of automation systems, and material flow throughout a CM system. Therefore, the scope of validation continues to demonstrate the ability of the CM system to consistently manufacture a product with the desired quality. ICH Q13 Guideline For therapeutic protein CM, any approach chosen to demonstrate the consistency of process performance and product quality should also consider sources of variability that may have a potential impact on product quality. This may include variability between batches purified from harvest materials collected up to the limit of in vitro cell age from a single cell bank thaw, as well as the potential variability between different batches purified from harvests of multiple cell bank thaws. Variability may be evaluated either as part of process validation or through alternative studies, if justified. Alternative process validation approaches (e.g., continuous process verification) may be considered when justified. Elements such as risk assessment, applicability of development data, control strategy, and prior knowledge may be considered in determining the suitability of an alternative process validation approach. 3.2. Run Time Considerations Bioreactors for CM may operate for significantly longer periods of time than bioreactors for batch manufacturing. The approach to establish a limit of in vitro cell age for production cells does not differ, regardless of the mode of bioreactor operation. Previously established limits of in vitro cell age for a bioreactor operating in a batch mode run may not be applicable to a bioreactor operating in a continuous mode under different culture conditions. The limit of in vitro cell age used for production should be based on data derived from production cells expanded under pilot-plant scale or commercial-scale conditions to the proposed in vitro cell age or beyond as outlined in ICH Q5A, Q5B and Q5D. Run time considerations should include factors such as the control of all adventitious agents (e.g., viruses, bacteria, fungi, mycoplasma) and resin and membrane lifetimes. Viral testing should be conducted as outlined by ICH Q5A, and an appropriate microbial control strategy should be established. 3.3. Viral Clearance Validation The general recommendations outlined in ICH Q5A for viral safety and clearance remain applicable for CM. Where recommendations may not be applicable to a CM system, scientifically justified alternatives may be proposed. ICH Q13 Guideline ANNEX IV: INTEGRATED DRUG SUBSTANCE AND DRUG PRODUCT CONTINUOUS MANUFACTURING 1. INTRODUCTION Annex IV supplements the main guideline by providing additional regulatory and scientific considerations that are relevant for the development and implementation of integrated drug substance and drug product CM processes (referred to as integrated process(es) hereafter). This annex also provides an example of an integrated process for a small molecule tablet dosage form. The example and approaches described in this annex are not exhaustive. Alternative approaches can be used. 2. INTEGRATED SMALL MOLECULE DRUG SUBSTANCE/DRUG PRODUCT PROCESSES 2.1. Characteristics of Drug Substance and Drug Product Process Steps Considering the differences between the drug substance and drug product process steps enables appropriate design of an integrated process. For example, process steps for drug substance and drug product manufacturing can have different RTDs, and a prevalence for liquid or solid input material addition can lead to a different frequency of in-process measurements. These differences are expected to influence the selection of equipment, equipment connections, surge lines or tanks, and the locations of in-process measurements and material diversion. 2.2. Example of an Integrated Process Figure 4, which is not intended to represent a regulatory flow diagram, illustrates a fully continuous integrated drug substance and drug product process. It shows the following elements: • Material addition points for liquids and solids • Each process step used for drug substance and drug product manufacturing • Process design for the interface between the drug substance and drug product • Sampling locations for all in-line/at-line/offline measurements, including PAT (shown by T1–T5) • All diversion points (shown by D1–D4) In this example, chemical reaction using flow reactors, continuous crystallisation, and crossflow filtration are used to obtain the drug substance as a highly concentrated crystal slurry. A wet granulation process consisting of blending, granulation, drying, milling, compression and coating unit operations is used to obtain a tablet drug product. The selection of a wet granulation process for the manufacture of the drug product permits the drug substance and drug product processes to be integrated through the continuous filtration line. The concentrated crystal slurry functions as both the drug substance source and the granulation fluid. No surge lines or tanks are used. ICH Q13 Guideline Other process schemes—including, for example, different purification methods, surge tanks, mix of batch and continuous unit operations—could also be used in the design of an integrated process. Details should be provided on how drug substance purity is ensured. *[Figure 4: Example of an integrated drug substance and drug product CM system]* ICH Q13 Guideline 2.3. Process Design, Monitoring and Control Monitoring points create several process segments, as illustrated in Figure 4 (i.e., from the first drug substance reactor up to location T1, process steps from T1 to T2, etc.). The sampling strategy could be based on RTD characterisation of individual steps, process segments, or the entire process. In this example, the RTD of the drug substance process segment provides a suitable time frame to monitor drug substance quality in real time, considering an appropriate sampling frequency, test method, time needed for measurement, and instrument capability. Location T1/D1 is used for sampling drug substance for offline testing or for diversion of drug substance, as necessary. Diversion of material impacts mass flow and may require a compensation strategy in the downstream operations considering the RTD. Allowable variations (including minor disturbances) identified through DOE or other suitable studies are incorporated into the process control strategy. In this example, the process parameter ranges for material additions and reactors, as well as the magnitude and duration of an allowable disturbance, are based on the variations shown to be within the purification capability of the crystallisation step, so there would be no adverse impact on the drug substance purity and impurity profile. An additional risk-based safety margin is included in the established thresholds to ensure all non-conforming material is diverted. Variations outside these thresholds result in material diversion using a suitable method for material traceability (e.g., RTD model). Ongoing assessment of equipment performance helps predict and prevent potential problems and ensures the ability of a CM process to operate as intended over time. Two such examples are: (1) during continuous filtration, monitoring filter back pressure to evaluate filter saturation (maximum pressure) and prevent filter failure; and (2) during material feeding using LIWFs, monitoring the feeder screw speed in relation to its maximum capacity to inform low feeder fill-level. Monitoring of equipment performance could be used to support how process control will be ensured, especially during long run times. 2.4. Start-up and Shutdown Individual unit operations of an integrated drug substance and drug product process could achieve desired operating conditions at different times due to differences in the type of transformation (e.g., chemical versus physical transformation) and the residence time in the equipment. When such differences occur, careful planning of start-up and shutdown sequences reduces waste. 2.5. RTD Characterisation for System Dynamics and Material Traceability Refer to the main guideline for RTD characterisation. As an integrated process has liquid and solid process streams, different approaches or tracers may be used to characterise various process segments considering the physical state of material in the flow stream (e.g., solution, slurry, solid). 3. SPECIFICATION AND BATCH DATA 3.1. Drug Substance Specification Even though the drug substance is not isolated in an integrated drug substance and drug product process, a drug substance specification should be defined and justified in accordance with ICH Q6A and other relevant ICH guidelines. Institution of a drug substance specification defines the quality of the drug substance, as well as facilitates the management of lifecycle activities (e.g., ICH Q13 Guideline facility changes), investigation of adverse events and product recalls, development of pharmacopeial monographs, and the establishment of a reference standard. Although a drug substance specification should be instituted, drug substance testing may not be required on a routine basis when the integrated process is appropriately controlled. A set of process performance criteria may be defined such that the drug substance could be considered “conforms to specification, if tested” when those process performance criteria are met. To ensure there is a comprehensive monitoring of the quality of the drug substance during the lifecycle of the product, conformance to the drug substance specification should be verified on a periodic and event-driven basis by testing the purified drug substance at an appropriate location using a relevant sampling plan. The frequency of the periodic verification should be defined and justified. Drug substance periodic verification can be based on pre-selected batches and/or at predetermined time intervals (e.g., every 5th batch or if manufactured infrequently, annually). Event-based verifications could be triggered by a change in supplier, starting material, synthesis conditions, or other factors considering risk. Refer to ICH Q6A for additional details on periodic testing. Appropriate sampling locations should be incorporated into the process design to enable testing of the drug substance (e.g., location T1 in Figure 4). Any modifications made to the sample to enable the test (e.g., drying of the crystal slurry for testing crystalline form) should be incorporated into the test methodology. Sampling locations should be identified in the drug substance specification. Although the drug substance is not isolated, the origin and fate of potential impurities (e.g., related substances, residual solvents, catalysts), robustness of impurity clearance, and impurity carryover from the drug substance into the drug product should be provided in the dossier. The control of impurities formation and clearance should be integrated into the overall control strategy. 3.2. Drug Product Specification In integrated processes, attributes typically associated with the drug substance quality are generally included in the drug product specification unless justified per ICH Q6A. Therefore, the drug product specification in an integrated process should include drug substance-related substances, residual solvents (used in drug substance synthesis), elemental impurities, etc., when appropriate. The specified impurities in the drug product specification may differ from the specified impurities in the drug substance specification. Sampling location should be appropriately identified in the drug product specification table, as some testing (e.g., testing for drug substance periodic verification as described above) may need to be performed following the drug substance purification step (before drug product formation). 3.3. Example of a Drug Substance and Drug Product Specification An example of a drug substance and drug product testing approach for an integrated process based on Figure 4 is shown in Table 4. The test attributes listed are considered relevant for this example. The specific details of each integrated process should be considered in the selection of the appropriate test attributes and testing plan. ICH Q13 Guideline Table 4: Example of a testing approach for an integrated CM Test Attribute1 Drug Substance Specification for Periodic Testing Drug Product Specification for Routine Testing of Every Batch Test Sampling Location Test Sampling Location Description N/A N/A Coated tablets Identity Use drug product test result PAT at tablet feed frame (T4) Crystalline Form2 Sampling Location T1 N/A Not tested when justified Chirality3 Sampling Location T1 N/A Not tested when justified Particle Size Sampling Location T1 N/A Not tested Purity Sampling Location T1 N/A Not tested Assay N/A N/A Core tablets, Sampling Location combination of T4 (blend uniformity) and T5 (tablet weight) Impurities4 Impurity specification for drug substances and drug products may differ Related Substance Sampling Location T1 (at-line high performance liquid chromatography (HPLC))4 Sampling Location T1 (at-line HPLC)4 or Coated Tablets (offline HPLC testing), as appropriate Residual Solvents Elemental Impurities Mutagenic Impurities Dissolution N/A N/A Coated Tablets Uniformity of dosage units N/A N/A Uncoated Tablets Water content N/A N/A Coated Tablets Microbial limits N/A N/A Coated Tablets 1 Include tests that are necessary to ensure the identity, strength, quality and purity of the drug substance and bioavailability of the drug product as per ICH Q6A. 2 In this example, crystalline form is considered a critical quality attribute for the drug substance and hence tested periodically. Crystalline form is not tested in the drug product as lack of form change during drug product processing has been demonstrated. 3 In this example, chirality is considered a critical quality attribute for the drug substance. 4 Tests that are common to both drug substance and drug product specification need to be tested only at one location; the same test result can be used for the drug substance and drug product. 3.4. Batch Data Although the drug substance is not isolated, small, planned diversions during process development should be used to obtain batch data that is representative of commercial drug substance. 4. STABILITY REQUIREMENTS 4.1. Drug Substance Stability Drug substance stability data to define a re-test period is not applicable as the drug substance is not isolated and stored in an integrated process. Drug substance stability data may be appropriate ICH Q13 Guideline for other aspects, such as to support the storage of in-house reference standards and to gain an understanding of product stability profiles. Institution of a hold time enables temporary storage of drug substance during an interruption in production. 4.2. Drug Product Stability The ICH stability guidelines and Section 4.5 of the main guideline are applicable to drug product made by an integrated process. 5. LOCATION OF DRUG SUBSTANCE AND DRUG PRODUCT INFORMATION IN THE CTD Drug substance and drug product information could be provided in the respective CTD sections 3.2.S and 3.2.P of the dossier. A description of the process step that integrates the drug substance and drug product could be based on its relevancy to the respective section. For example, in the process example provided in this annex, the continuous filtration process could be described in CTD section 3.2.S as it is related to concentration of the drug substance. The integrated flow diagram can be provided in CTD section 3.2.P and referenced in section 3.2.S. ICH Q13 Guideline ANNEX V: PERSPECTIVES ON MANAGING DISTURBANCES 1. INTRODUCTION This annex describes examples of approaches for managing transient disturbances (hereafter referred to as disturbances in this annex) that may occur during CM. The discussion points presented here are not exhaustive. Alternative approaches can be used. 2. BACKGROUND Disturbances may result in a variation in material quality. The impact of some variations on material quality in an earlier process step may be resolved by downstream process steps. The extent of variations and the ability to resolve them in subsequent steps are impacted by the amplitude, duration, and frequency of the disturbance. Identification of tolerable ranges for these parameters and establishing appropriate acceptance criteria will enable the development of an effective strategy for managing disturbances. Manufacturers may use various methodologies (e.g., DOE, RTD studies, a combination of both) to understand the impact of disturbances. Funnel plot predictions based on an RTD model can be a useful tool to understand the qualitative and quantitative impact of the amplitude and duration of a disturbance on material quality. Figure 5 shows a funnel plot for drug substance feeding in a drug product CM process (similar to the example in Annex II). Funnel plots are specific to the formulation, process conditions, and system configuration used in RTD model development. Information from the funnel plot helps to inform the selection of appropriate acceptance criteria for disturbances. For example, the dotted lines in the following funnel plot show that a disturbance of +/- 20% lasting less than 90 seconds would not cause the drug concentration in the blend to exceed the 90–110% label claim (LC). *[Figure 5: Example of a funnel plot for the feeding of a drug substance]* ICH Q13 Guideline 3. MANAGEMENT OF DISTURBANCES Manufacturers may develop various approaches to manage disturbances considering the specific details of the CM system and the risk to material quality from disturbances. Three examples considering different risks of a disturbance are provided below: • Example 1: The amplitude and duration of the disturbance meet predefined acceptance criteria for the disturbance, and the occurrence of such disturbances is infrequent. • Example 2: The amplitude or duration of the disturbance exceeds the predefined acceptance criteria for the disturbance, and the occurrence of such disturbances is infrequent. • Example 3: The amplitude and duration of each disturbance meet predefined acceptance criteria for the disturbance, but multiple, frequent disturbances are observed. These examples focus on the impact of disturbance from a loss-in-weight feeder (LIWF) on the drug concentration in the blend for a CM process similar to that described in Annex II, given that all other parameters being monitored meet the predefined acceptance criteria. These examples use the information in the funnel plot (Figure 5) and, for the purpose of discussion, assume that the acceptance criteria for the magnitude and duration of an LIWF disturbance is +/- 20% lasting for 80 seconds. These examples help illustrate the important considerations in management of disturbances under selected scenarios, which may also be applicable to drug substances and other CM processes. 3.1. Disturbance Example 1 *[Figure 6: Example of an infrequent disturbance that is within the acceptance criteria for]* disturbances ICH Q13 Guideline Description: Figure 6 illustrates a drug substance LIWF with an infrequent transient +20% flow spike lasting 40 seconds, which is within the predefined acceptance criteria for disturbances. This disturbance causes an increase in the amount of the drug substance fed into the blender, before returning to normal operating condition. The funnel plot (Figure 5) shows that following this disturbance, the drug substance concentration in the blend remains within the 90–110% acceptance criteria, due to back mixing. An additional quality check, such as measurement of the drug substance concentration at a suitable location (e.g., NIR measurements at the tablet press feed frame) could be considered, to confirm the blend is within 90–110%. Impact: Although this disturbance represents an excursion from normal operation, the quality of the output material is not affected as the magnitude/amplitude of the disturbance and product quality meet their predefined acceptance criteria. Action: No material is diverted. Collection of the output material continues, and the process continues to operate. No investigation is needed, because such a disturbance has been evaluated during development and impact on material quality is understood. 3.2. Disturbance Example 2 *[Figure 7: Example of an unexpected disturbance that is outside the acceptance criteria for]* disturbances Description: Figure 7 illustrates a drug substance LIWF with an unexpected transient +20% flow spike lasting 300 seconds. The disturbance is outside the predefined acceptance criteria for disturbances. This disturbance causes an increase in the amount of the drug substance fed into the blender before returning to normal operating condition. The funnel plot (Figure 5) shows that following this disturbance, the drug substance concentration in the blend exceeds the 90–110% ICH Q13 Guideline acceptance criterion. An additional quality check, such as measurement of the drug substance concentration at a suitable location (e.g., NIR measurements at the tablet press feed frame), confirms the blend exceeds 110%. Impact: The quality of the output material is adversely impacted as the disturbance duration exceeds the predefined acceptance criteria. Action: The process continues to operate while the non-conforming material is diverted according to a pre-established procedure, and the time to start and end diversion is controlled by the automation system. The system returns to normal material collection mode when the non- conforming material is completely diverted. If needed, a concurrent investigation is initiated to determine root cause. Diverted Amount: The amount of material diverted depends on the control strategy used (including specific triggers for material diversion) and on the process dynamics from the point of disturbance detection and the point at which material diversion ends. Inclusion of confidence intervals in the RTD provides a safety margin to ensure all non-conforming material is diverted from the batch. Additional factors, such as the sampling strategy and the ability to trace and remove materials, are considered in establishing the criteria for material diversion. 3.3. Disturbance Example 3 *[Figure 8: Example of disturbances that are within the acceptance criteria for disturbances,]* but occur frequently Description: Figure 8 illustrates a drug substance LIWF with multiple frequent transient +20% flow spikes, each lasting 40 seconds, resulting in variability in the amount of material fed into the blender. ICH Q13 Guideline Impact: Although each disturbance meets the predefined acceptance criteria for disturbances, it occurs with a high frequency over a short time period. In this example, the system cannot dampen these multiple disturbances sufficiently, thus resulting in non-conforming materials. Action: The impact of these disturbances on system performance and output material quality is monitored closely (e.g., NIR method, other elements of the control strategy). Process operation and product collection continue until one or more elements of the control strategy do not meet the predefined acceptance criteria. When a criterion is no longer met, the material is diverted according to a pre-established procedure. If high-frequency disturbances persist, process operation may be paused. An investigation is conducted to understand the root cause for these frequent disturbances. Such investigations enable preventative actions to be taken to avoid equipment failure and adverse impact on critical quality attributes, ensure process performance (e.g., robustness), etc. Assessment of process capability or other evaluations may also be warranted. Setting acceptance criteria for the frequency of disturbances could also be considered to aid the management of disturbances. Diverted Amount: The amount diverted is the same as described in Section 3.2 of this annex. The disposition of the diverted material and the entire batch is assessed upon completion of the investigation. --- ### Document: ICH Q14 Complete (ICH) # ICH Harmonised Guideline Q14 (2023): Analytical Procedure Development INTERNATIONAL COUNCIL FOR HARMONISATION OF TECHNICAL REQUIREMENTS FOR PHARMACEUTICALS FOR HUMAN USE ICH HARMONISED GUIDELINE ANALYTICAL PROCEDURE DEVELOPMENT Q14 Final Version Adopted on 1 November 2023 This Guideline has been developed by the appropriate ICH Expert Working Group and has been subject to consultation by the regulatory parties, in accordance with the ICH Process. At Step 4 of the Process the final draft is recommended for adoption to the regulatory bodies of ICH regions. Q14 Document History Code History Date Q14 Endorsement by the Members of the ICH Assembly under Step 2 and release for public consultation 24 March 2022 Q14 Adoption by the Regulatory Members of the ICH Assembly under Step 4 1 November 2023 Q14 Error Corrections: Alignment of glossary terms (Intermediate precision, Performance Characteristic, Range, Reportable Range and Working Range) with ICH Q2(R2), Minor Format corrections to Table 1 and Table 6 and *[Figure 3 alignment to Table 6.]* 4 April 2025 Legal notice: This document is protected by copyright and may, with the exception of the ICH logo, be used, reproduced, incorporated into other works, adapted, modified, translated or distributed under a public license provided that ICH's copyright in the document is acknowledged at all times. In case of any adaption, modification or translation of the document, reasonable steps must be taken to clearly label, demarcate or otherwise identify that changes were made to or based on the original document. Any impression that the adaption, modification or translation of the original document is endorsed or sponsored by the ICH must be avoided. The document is provided "as is" without warranty of any kind. In no event shall the ICH or the authors of the original document be liable for any claim, damages or other liability arising from the use of the document. The above-mentioned permissions do not apply to content supplied by third parties. Therefore, for documents where the copyright vests in a third party, permission for reproduction must be obtained from this copyright holder. i ICH HARMONISED GUIDELINE ANALYTICAL PROCEDURE DEVELOPMENT Q14 ICH Consensus Guideline TABLE OF CONTENTS 1. INTRODUCTION .................................................................................................................. 1 1.1 Objective ................................................................................................................................. 1 1.2 Scope ........................................................................................................................................ 1 2. GENERAL CONSIDERATIONS FOR ANALYTICAL PROCEDURES ........................ 1 2.1 Minimal versus Enhanced Approaches to Analytical Procedure Development ....................... 2 2.2 The Analytical Procedure Lifecycle ......................................................................................... 2 3. ANALYTICAL TARGET PROFILE ................................................................................... 3 4. KNOWLEDGE AND RISK MANAGEMENT IN ANALYTICAL PROCEDURE DEVELOPMENT AND CONTINUAL IMPROVEMENT .......................................................... 4 4.1 Knowledge Management ......................................................................................................... 4 4.2 Risk Management .................................................................................................................... 4 5. EVALUATION OF ROBUSTNESS AND PARAMETER RANGES OF ANALYTICAL PROCEDURES ................................................................................................................................. 5 5.1 Robustness ............................................................................................................................... 5 5.2 Analytical Procedure Parameter Ranges .................................................................................. 5 6. ANALYTICAL PROCEDURE CONTROL STRATEGY ................................................. 6 6.1 Established Conditions for Analytical Procedures ................................................................... 7 7. LIFECYCLE MANAGEMENT AND POST-APPROVAL CHANGES OF ANALYTICAL PROCEDURES ...................................................................................................... 7 8. DEVELOPMENT OF MULTIVARIATE ANALYTICAL PROCEDURES: ADDITIONAL CONSIDERATIONS ............................................................................................. 11 9. DEVELOPMENT OF ANALYTICAL PROCEDURES FOR REAL TIME RELEASE TESTING: ADDITIONAL CONSIDERATIONS ........................................................................ 14 10. SUBMISSION OF ANALYTICAL PROCEDURE RELATED INFORMATION ........ 15 10.1 General Regulatory Considerations and Documentation ....................................................... 15 10.2 Documentation for the Enhanced Approach .......................................................................... 15 10.3 Documentation for Multivariate Analytical Procedures ....................................................... 15 11. GLOSSARY .......................................................................................................................... 16 12. REFERENCES ..................................................................................................................... 22 13. ANNEX ................................................................................................................................. 23 ICH Q14 Guideline ii 13.1 Annex A: Examples of application of ICH Q14 principles .................................................... 23 #### 13.1.1 Measurement of Stereoisomers as Specific Process Related Impurities in a Small Molecule Drug Substance (DS) .............................................................................................. 25 13.1.2 Measurement of Potency for an anti-TNF-alpha Monoclonal Antibody .................... 30 13.2 Annex B: Example of Multivariate Model Lifecycle Components ....................................... 36 ICH Q14 Guideline 1. INTRODUCTION ### 1.1 Objective This guideline describes science and risk-based approaches for developing and maintaining analytical procedures suitable for the evaluation of the quality of drug substances and drug products. The systematic approach suggested in ICH Q8 Pharmaceutical Development together with principles of ICH Q9 Quality Risk Management can also be applied to the development and lifecycle management of analytical procedures. When developing an analytical procedure, a minimal (also known as traditional) approach or elements of an enhanced approach can be applied. Furthermore, the guideline describes additional considerations for the development of multivariate analytical procedures and for real time release testing (RTRT). This guideline complements ICH Q2 Validation of Analytical Procedures. Using the tools described in ICH Q12 Technical and Regulatory Considerations for Pharmaceutical Product Lifecycle Management, the guideline describes principles to support change management of analytical procedures based on risk management, comprehensive understanding of the analytical procedure and adherence to predefined criteria for performance characteristics. Knowledge gained from application of an enhanced approach to analytical procedure development can provide better assurance of the performance of the procedure, can serve as a basis for the analytical procedure control strategy and can provide an opportunity for more efficient regulatory approaches to related post approval changes. The guideline also describes submission of analytical procedure development and related lifecycle information in the Common Technical Document (CTD) format (ICH M4Q, The Common Technical Document for the Registration of Pharmaceuticals for Human Use). Information related to analytical procedure development and knowledge may be submitted to regulatory authorities to provide additional evidence that the analytical procedure is fit for the intended purpose. While the minimal approach remains a valid approach, an applicant can decide to submit additional development data and knowledge which may facilitate regulatory communication for post approval change management. ### 1.2 Scope This guideline applies to analytical procedures used for release and stability testing of commercial drug substances and products, hereafter referred to as ‘products’. The guideline can also be applied to other analytical procedures used as part of the control strategy (ICH Q10 Pharmaceutical Quality System) following a risk-based approach. The scientific principles described in this guideline can be applied in a phase-appropriate manner to analytical procedures used during clinical development. 2. GENERAL CONSIDERATIONS FOR ANALYTICAL PROCEDURES The goal of development is to obtain an analytical procedure fit for the intended purpose: to measure an attribute or attributes of the material with the needed specificity/selectivity, accuracy, precision over the reportable range. Details of the performance characteristics considered for analytical procedure validation are described in ICH Q2. In this section the minimal and enhanced approaches to analytical procedure development are described. While the minimal approach remains an acceptable approach to development of a robust analytical procedure that is fit for the intended purpose, some or all elements of the enhanced approach might be used to support development and lifecycle management of analytical procedures. ICH Q14 Guideline In certain cases, an analytical procedure can be applied to multiple products with little or no modification of measurement conditions. For a new application of such platform analytical procedures, the subsequent development can be abbreviated, and certain validation tests can be omitted based on a science- and risk-based justification. Data gained during the development studies (e.g., robustness data from a design of experiments (DoE) study) could be used as part of the validation data for the related analytical procedure performance characteristics and studies do not necessarily need to be repeated. ### 2.1 Minimal versus Enhanced Approaches to Analytical Procedure Development Analytical procedure development should include the following elements as a minimum: • Identifying the attributes of the product which need to be tested; • Selecting an appropriate technology and related instruments or suitable apparatus; • Conducting studies to evaluate analytical procedure performance characteristics such as specificity, accuracy and precision over the reportable range (including the calibration model, lower and/or higher range limits) and robustness; • Documenting the analytical procedure including the analytical procedure control strategy. The enhanced approach offers a systematic way of developing and refining knowledge of an analytical procedure and demonstrating procedure understanding. Product and process understanding informs the quality attributes to be tested. The anticipated performance criteria for relevant performance characteristics should be documented in an analytical target profile (ATP). In addition to the elements of the minimal approach, an enhanced approach may include the following elements as appropriate: • Conducting risk assessment and evaluating prior knowledge to identify the analytical procedure parameters that can impact performance of the procedure; • Conducting uni- or multi-variate experiments and/or modelling to explore ranges and interactions between identified analytical procedure parameters; • Defining an analytical procedure control strategy including set-points and/or ranges for relevant analytical procedure parameters. These could include proven acceptable ranges for analytical procedures (PARs) and/or method operable design regions (MODRs). Applying elements of the enhanced approach to development can lead to a better understanding of the impact of analytical procedure parameters on the analytical procedure performance and more flexibility for lifecycle management, such as wider operating ranges and a more appropriate set of established conditions (ECs) with associated reporting categories. ### 2.2 The Analytical Procedure Lifecycle *[Figure 1 depicts elements of the analytical procedure lifecycle as related to the product lifecycle.]* Analytical procedure development and change management approaches are described in this guideline whereas analytical procedure validation is described in ICH Q2. Depending on the intended purpose of the analytical procedure and the development approach taken, the order and extent of each element could vary, and several elements could occur simultaneously. ICH Q14 Guideline *[Figure 1: The analytical procedure lifecycle]* 3. ANALYTICAL TARGET PROFILE Product and process understanding (ICH Q8 and ICH Q11 Development and Manufacture of Drug Substances) leads to the identification of critical quality attributes (CQAs) requiring analytical measurement for control which may be included in the quality target product profile (QTPP). Measurement needs can be captured in an ATP which forms the basis for development of the analytical procedure. An ATP consists of a description of the intended purpose of the analytical procedure, appropriate details on the product attributes to be measured and relevant performance characteristics with associated performance criteria. The ATP includes measurement requirements for one or more quality attributes. The ATP drives the choice of analytical technology. Multiple available analytical techniques may meet the performance criteria. Consideration of the operating environment (e.g., at-line, in-line or off-line) should be included in the technology selection. Once a technology has been selected, the ATP serves as a foundation to derive the analytical procedure attributes and performance criteria for analytical procedure validation (ICH Q2). Formal documentation and submission of an ATP is optional but can facilitate regulatory communication irrespective of the chosen development approach. The ATP also facilitates ongoing monitoring and continual improvement of the analytical procedure. The ATP is maintained over the lifecycle and can also be used as a basis for lifecycle management to ensure that the existing, revised or new analytical procedure remains fit for the intended purpose. Illustrative examples of ATPs are provided in Annex A. ICH Q14 Guideline 4. KNOWLEDGE AND RISK MANAGEMENT IN ANALYTICAL PROCEDURE DEVELOPMENT AND CONTINUAL IMPROVEMENT ### 4.1 Knowledge Management As with product and manufacturing process development, knowledge management (ICH Q10) plays a critical role in analytical procedure development and during the lifecycle of the analytical procedure. Prior knowledge is explicitly or implicitly used for informing decisions during analytical procedure development and lifecycle management. Prior knowledge can be internal knowledge from a company’s proprietary development and analytical experience, external knowledge such as reference to scientific and technical publications or established scientific principles. Prior product knowledge plays an important role in identifying suitable analytical techniques. Knowledge of best practices, state-of-the-art technologies and regulatory expectations contribute to the selection of the most suitable technology for a given purpose. Existing platform analytical procedures (e.g., protein content measurement by UV spectroscopy) can be leveraged to evaluate the attributes of a specific product without conducting additional procedure development. As additional information is obtained, knowledge related to analytical procedures should be actively managed throughout the product lifecycle. ### 4.2 Risk Management The use of quality risk management (QRM) is encouraged to aid in the development of a robust analytical procedure to reduce risk of poor performance and reporting incorrect results. Risk assessment is typically performed early in analytical procedure development and is updated as more information becomes available. Risk assessment can be formal or informal and can be supported by prior knowledge. Risk assessment tools as described in ICH Q9 Annex 1 can be used to: • identify analytical procedure parameters (factors and operational steps) with potential impact on its performance, e.g., Annex A Figure 2 (Ishikawa diagram); • assess the potential impact of analytical procedure parameters on the analytical procedure performance; • identify and prioritise analytical procedure parameters to be investigated experimentally; • inform the need and the extent of ongoing monitoring as part of risk review. Risk communication should be used to support continual improvement of the analytical procedure performance throughout its lifecycle. The outcome of quality risk management should be documented in the relevant parts of the applicant’s pharmaceutical quality system (PQS) (ICH Q10). ICH Q14 Guideline 5. EVALUATION OF ROBUSTNESS AND PARAMETER RANGES OF ANALYTICAL PROCEDURES ### 5.1 Robustness The robustness of an analytical procedure is a measure of its capacity to meet the expected performance criteria during normal use. Robustness is tested by deliberate variations of analytical procedure parameters and should consider the duration of the analysis (including stability of sample preparations and reagents). Prior knowledge and risk assessment can inform the selection of parameters to investigate during the robustness study. Those parameters likely to influence procedure performance over the intended period of use should be studied. For most procedures, robustness evaluation is conducted during development. If the evaluation of robustness was already conducted during development, it does not need to be repeated during validation (as discussed in ICH Q2). Data from validation studies (e.g., intermediate precision) can complement robustness evaluation. For some analytical procedures with inherent high parameter variability (e.g., those requiring biological reagents) wider parameter ranges may need to be investigated during robustness studies. Robustness of multivariate procedures may require additional considerations (see Chapter 8). The outcome of the evaluation of robustness should be documented and also reflected in the analytical procedure control strategy. ### 5.2 Analytical Procedure Parameter Ranges Experiments to investigate parameter ranges can provide additional knowledge about the analytical procedure performance. The respective analytical procedure attributes and associated criteria could be derived from the ATP. Univariate examination of a single parameter can establish a PAR for the analytical procedure. In an enhanced approach, the ranges for the relevant parameters and their interactions can be investigated in multivariate experiments (DoE). Risk assessment and prior knowledge should be used to identify analytical procedure parameters, attributes and associated ranges to be investigated experimentally. Categorical variables (e.g., different instruments) can also be considered as part of the experimental design. The outcome of development studies should provide an understanding of the relationships between analytical procedure parameters (inputs) and the responses of the analytical procedure (outputs). Based on the results, fixed set-points may be defined for some parameters. For others, PARs could be defined while still others could be included into an MODR. An MODR consists of combined ranges for two or more analytical procedure parameters within which the analytical procedure is shown to be fit for the intended purpose. Set-points, PARs and/or MODRs of an analytical procedure proposed by the applicant based on development and validation data are subject to regulatory approval. Moving within an approved PAR or MODR does not require regulatory notification. Analytical procedure validation for a PAR and/or an MODR is required only for those performance characteristics not covered by data from analytical procedure development. For practical reasons and following a risk-based approach, it may not be necessary or possible to validate the entirety of an MODR. The part of a PAR or an MODR intended for routine use (typically the intended operational conditions or the set point) in the analytical procedure must be covered by validation data. The extent of validation tests should be justified on a case-by- case basis. For future changes to operational conditions within a PAR or an MODR an assessment of the need for and extent of additional validation tests should be performed. An analytical procedure ICH Q14 Guideline validation strategy, e.g., as part of the analytical procedure validation protocol, can define the necessary extent of additional validation. 6. ANALYTICAL PROCEDURE CONTROL STRATEGY An analytical procedure control strategy should ensure that the analytical procedure is fit for the intended purpose during routine use throughout its lifecycle. It consists of a set of controls, derived from current understanding of the analytical procedure including development data, risk assessment, robustness and prior knowledge. The analytical procedure control strategy should be defined before validation (ICH Q2) and should be confirmed after validation has been finalised. The analytical procedure control strategy includes analytical procedure parameters needing control and the system suitability test (SST) which is part of the analytical procedure. The analytical procedure should describe the steps necessary to perform each analytical test. This can include (but is not limited to) the sample, the reference materials and the reagents, sample and control preparations, use of the apparatus, generation of the calibration curve, the number of replicates, use of the formulae for the calculation of the reportable results and other necessary steps. The level of detail should enable a skilled analyst to perform the analysis and interpret the results (such as the level of detail in a regional pharmacopoeia for a similar product). The SST depends on the type and intent of the analytical procedure and is typically conducted with one or more predefined materials (including use of positive and/or negative controls). The SST is designed to verify selected analytical procedure attributes. The acceptance criteria should be based on analytical procedure performance criteria. The components of the SST should be selected using risk assessment as well as knowledge and understanding from development data. The test is used to verify that the measurement system and the analytical operations associated with the analytical procedure are fit for the intended purpose during the time period of analysis and enable the detection of unacceptable performance. Validity of the results of the analytical procedure depends on the outcome of the SST. In the enhanced approach, a well-designed set of SST parameters and criteria to ensure analytical procedure performance could represent an important aspect of risk mitigation. For analytical procedures relying on multivariate models, data quality should be verified using suitable software tools. In addition to SST, sample suitability assessment may be required to ensure acceptable sample response. A sample and/or sample preparation is considered suitable if the measurement response of the sample satisfies pre-defined acceptance criteria for the analytical procedure attributes that have been developed for the validated analytical procedure (often used for biologics). In these cases, sample suitability is a prerequisite for the validity of the result along with a satisfactory outcome of the SST. Sample suitability assessment generally consists of the assessment of the similarity of the response between a reference material and the test sample and may include a requirement for acceptable levels of interfering signals arising from the sample matrix. For analytical procedures relying on multivariate models, sample suitability assessment can be verified using suitable software tools which check if the sample fits within the model space. This is commonly called data quality check. Ongoing monitoring of selected analytical procedure outputs is recommended to look for any trends, in line with PQS expectations. Review of analytical procedure outputs facilitates the procedure lifecycle management and enables proactive intervention to avoid failures. ICH Q14 Guideline ### 6.1 Established Conditions for Analytical Procedures In line with ICH Q12, applicants may propose ECs for an analytical procedure. ECs can be identified using tools highlighted in Chapter 2 including risk assessment, prior knowledge, and results from uni- and/or multi-variate experimentation. The nature and extent of ECs will depend on the development approach, the complexity of the analytical procedure and a demonstrated understanding of how parameters and other factors impact the analytical procedure performance. With a minimal approach to analytical procedure development, the number of ECs may be extensive with fixed analytical procedure parameters and set points. With an enhanced approach, there should be an increased understanding of the measurement requirements, the suitability of available technologies and the relationship between analytical procedure parameters and performance. This knowledge facilitates the identification of an appropriate set of ECs and related reporting categories (see Chapter 7). ECs can be reduced and focused on analytical procedure performance (e.g., acceptable ranges for analytical procedure parameters, performance characteristics with associated criteria) when justified by analytical procedure understanding (including prior knowledge and product/process knowledge) and risk management. ECs could consist of: • Performance characteristics and associated criteria (e.g., included in an ATP); • Analytical procedure principle (i.e., the physicochemical basis or specific technology); • SST and sample suitability assessment criteria; • Set points and/or ranges for one or more analytical procedure parameters. Analytical procedure parameters which need to be controlled to ensure the performance of the procedure as well as those where the need for control cannot be reasonably excluded should be identified as ECs. If the application of analytical procedure performance criteria and/or the SST demonstrate that a specific parameter is under control, that parameter or the parameter value may not necessarily need to be defined as an EC or may be assigned a lower reporting category as appropriate. ECs and related reporting categories are proposed by the applicant and assessed by the regulatory authorities for approval based on the scientific justification provided. Use of the enhanced approach should not lead to providing a less detailed description of analytical procedures in a regulatory submission. Suitably detailed descriptions of the analytical procedures in Module 3 of the CTD are expected to provide a clear understanding regardless of the approach used to identify ECs for analytical procedures. A description of an analytical procedure includes supportive information as well as identified ECs. Identification of reporting categories for ECs and the utilisation of ECs in change management are described in the next chapter. 7. LIFECYCLE MANAGEMENT AND POST-APPROVAL CHANGES OF ANALYTICAL PROCEDURES Changes to analytical procedures can occur throughout the product lifecycle and could involve modification of existing procedures or a complete replacement including introduction of a new technology. Major changes in the performance characteristics or additional information on quality attributes could lead to reevaluation of the ATP and/or a new procedure. Typically, process knowledge, analytical procedure knowledge and continual improvement are drivers for change. If possible, changes should lead to improved analytical procedures in line with best ICH Q14 Guideline practices and instrumentation. The tools and enablers discussed in ICH Q12 are applicable to analytical procedures, irrespective of the development approach and consist of: • Existing risk-based categorisation of changes to analytical procedures (in regional regulatory framework); • ECs; • Post-Approval Change Management Protocols (PACMPs); • The Product Lifecycle Change Management (PLCM) document; • The PQS (documentation of all changes including those not requiring regulatory submission); • Structured approaches for frequent Chemistry, Manufacturing and Controls (CMC) post approval changes. If ECs are not proposed in the dossier, any changes should be reported according to regional reporting requirements. The use of different elements of the enhanced approach can facilitate management and regulatory communication of post-approval changes as compared to the minimal approach. *[Figure 2: Risk-based approach for identification of ECs and reporting categories for]* associated changes in the enhanced approach 1) Including analytical procedure control strategy 2) In some cases, moderate risk changes proposed by the company may require prior approval based on health authority feedback If justified and validated (see Chapter 5.2), a PAR or MODR allows movement within the approved range(s) to be managed within a company’s PQS. Changes outside of the approved ranges or expansion of those ranges require regulatory communication. In cases where ECs are proposed, the risk associated with prospective changes should be assessed up front to propose the appropriate reporting category. Factors to consider include the criticality of the quality attribute being measured, the complexity of the technology and the extent of the change (see Annex A). Relevant risk reduction measures should be identified ICH Q14 Guideline based on product and process knowledge as well as analytical procedure understanding and the proposed analytical procedure control strategy. Finally, the level of risk (high, medium or low) should be assigned. In general, an understanding of the analytical procedure robustness and/or prior knowledge can be used to support risk mitigation associated with future changes. Submitting the outcomes of the risk assessments to regulatory authorities when ECs are proposed can help to justify reporting categories for future changes to analytical procedures. *[Figure 2 summarises how risk assessment and risk reduction measures can help to identify]* appropriate reporting categories for ECs. The risk associated with changes can be reduced by defining relevant performance criteria which are identified as ECs. Risk reduction is possible when sufficient understanding is available (Table 1) to design future bridging studies (Table 2). Adherence to the ATP and an analytical procedure control strategy ensures that the analytical procedure remains fit for the intended purpose after changes. Changes to parameters that are not ECs do not require regulatory communication. The ATP could also form the basis of a PACMP which would allow changes (e.g., a change between technologies) to be reported at a lower reporting category provided that the pre-defined requirements for the change are met. Examples are provided in Annex A on how appropriate reporting categories can be proposed. Table 1: Relationship between knowledge (understanding), risk and extent of studies for changes to analytical procedures Knowledge1) Low High Risk associated with the change Low High Prior knowledge or confirmatory study according to a study plan derived from prior knowledge In depth study according to a study plan derived from prior knowledge Confirmatory study according to a study plan In depth study according to a study plan 1) As described in ICH Q10 When initiating changes to analytical procedures, QRM can be used to evaluate the impact of the changes and reconfirm that the originally agreed reporting category is still appropriate. The outcome of this risk assessment informs the design and extent of the studies needed to support the change including a bridging strategy to demonstrate that the revised or new procedure remains fit for the intended purpose. When considering a bridging strategy, a greater understanding of the analytical procedure can enable a reduced study design whereas a higher risk change may need a more in-depth study (Table 1). The implementation of an already validated analytical procedure at a different location, including the concept of analytical procedure transfer, should follow a similar bridging strategy (Table 2). ICH Q14 Guideline For product and process changes, a reassessment and potential adaptation of the ATP, if used, and a reassessment of the suitability of the analytical procedure may be necessary. If an applicant proposes a new analytical procedure, a comprehensive risk assessment and evaluation should be conducted to determine any impact on the performance. The analytical procedure control strategy for the new procedure should be established. ECs associated with the new procedure should be justified when communicating the change. Table 2: Examples of analytical procedure change evaluation Risk Factor: Extent of change Bridging strategy Evidence of the suitability of a new procedure Change of analytical procedure principle (physicochemical/biochemical basis) Full validation of new procedure And Comparative analysis of representative samples and reference materials. And/or Demonstration that the analytical procedure’s ability to discriminate between acceptable and non-acceptable results remains comparable Analytical procedure performance characteristics are evaluated and criteria are met after the change And Results are comparable after change or differences are acceptable and potential impact on specification evaluated Change within same analytical procedure principle Partial or full revalidation of the analytical procedure performance characteristics affected by the change And, as appropriate Comparative analysis of representative samples and reference materials And/or Demonstration that the analytical procedure’s ability to discriminate between acceptable and non-acceptable results remains comparable Analytical procedure attributes are evaluated and criteria are met after change And, as appropriate Results are comparable after change or differences are acceptable and potential impact on specification evaluated Transfer of analytical procedure to a different site with no change in procedure itself Partial or full revalidation of the analytical procedure performance characteristics And/or Comparative analysis of representative samples and reference materials Or Justification for not performing additional transfer experiments Analytical procedure attributes are evaluated and criteria are met after change And/or Results are comparable Table 2 provides examples of data recommended to support a change dependent on the extent of the change and the identified risk category. To support the use of the tools described in this guideline, the company´s PQS change management process should be effective and in line with recommendations described in ICH Q12. ICH Q14 Guideline 8. DEVELOPMENT OF MULTIVARIATE ANALYTICAL PROCEDURES: ADDITIONAL CONSIDERATIONS Multivariate analytical procedures are those where a result is determined through a multivariate calibration model utilising more than one input variable. The considerations provided here are for models using latent variables that are mathematically related to directly measured variables. Other approaches such as machine learning (e.g., neural networks) or optimisation techniques could use similar principles although the specific approach may vary and will not be discussed in detail. Whereas this chapter includes aspects unique to multivariate analytical procedures, the principles described in other parts of this guideline are also applicable. Development of a robust multivariate analytical procedure includes scientifically justified sample selection and distribution over the range, sample size, model variable selection and data pre-processing. Sample and sample population Multivariate models link measured model variables with values obtained from a validated reference analytical procedure or from reference samples. Therefore, samples in multivariate analysis consist of input measurements and their corresponding reference values, which are numeric values for quantitative measurements (e.g., assay) and classification categories for qualitative analytical procedures (e.g., identity). In some cases, one set of input measurements could be used for multiple models provided that more than one reference value exists. The reference values are determined using reference analytical procedure(s) or prepared reference samples with known values. Care should be taken to ensure that uncertainty in the reference analytical procedure is sufficiently low in relation to the intended performance of the multivariate analytical procedure and that prepared reference samples are homogeneous. The approach to the reference analytical procedure(s) or prepared reference samples should be explained and justified. The ranges of multivariate models are typically constructed by data from samples. Therefore, a careful strategy for sample selection is essential for obtaining the relevant information from the analytical data and contributes to the robustness of the resulting model. Based on the analytical procedure and measurement principle, the sample population should encompass the sources of variability likely to occur during manufacturing and analysis, such as raw material quality, manufacturing process variability, storage conditions, sample preparation and testing. Use of risk assessment tools can help to identify sources of variability with the potential to influence the measurements and resulting model outputs. Obtaining samples with appropriate variability at commercial scale can be challenging. Therefore, development laboratory and pilot scale samples are often utilised to provide enough variability to improve accuracy and robustness of the model. Inclusion of commercial scale samples is recommended to capture variability related to specific equipment and/or processing conditions. Careful consideration should also be given to sample distribution in the calibration and validation sets, as this will influence the model’s predictive capability. The number of samples used to create a calibration model for quantitative analysis will depend on the complexity of the sample matrix and/or interference by the matrix in the analyte signal of interest (i.e., for more complex sample matrices generally more samples are needed). Sufficient samples should be available for creation of calibration and validation sets of appropriate size and variability. Independent samples in the validation set are not incorporated in the calibration set or the internal test set. A validation sample set generated with samples from independent batches can be used to demonstrate model robustness. ICH Q14 Guideline Data transformation The selection of the data transformation method(s) can be driven by the type of data, instrument or sample, the intended purpose of the model and/or prior knowledge. Caution should be exercised when performing any transformation because artefacts can be introduced, or essential information can be lost. Any transformation of data should be documented and justified. Variable selection Variable selection is performed during model development. For example, wavelength range selection is frequently applied in spectroscopic applications to select a region of a spectrum that gives the best estimation of the selected chemical or physical property to be evaluated (modelled). Variable selection depends on the measurement principle, application and other factors, and should be justified. Robustness Model development should minimise the prediction error and provide a robust model that consistently assures the long-term performance. The robustness should be built into the model by including relevant sources of variability related to materials, process, environment, instrumentation or other factors. Sources of variability can be identified from prior knowledge and risk assessments and evaluated using statistical tools. Robustness depends on multiple factors, e.g., composition of the calibration set, data transformation method, variable selection and the number of latent variables. Optimisation of the multivariate model often requires a trade-off between accuracy and robustness. A critical factor is the number of latent variables to be used in the calibration model which ensures the model is optimised for the intended purpose. Selection of the number of latent variables occurs during model development and is confirmed during internal testing. Too many latent variables can result in model overfitting, potentially resulting in decreased robustness and a need for more frequent model updates. Justification for the final number of latent variables used should be provided. Diagnostic plots provided by software packages can be useful to support the justification. Recalibration and model maintenance Tracking the calibration model performance is an important part of ongoing monitoring for a multivariate analytical procedure. Various statistical tools can be employed as diagnostics to ensure that the model assumptions are upheld. For latent variable models, these diagnostic tools can include: • examination of residuals to determine unmodeled features of the data (e.g., x-residuals or F-probability); • outlier diagnostics to determine if the data is within the bounds of the model construction (e.g., Hotelling’s T-squared or Mahalanobis distance). Software packages allow for the application of diagnostic tools for model prediction. Additionally, continued performance of the calibration model should be confirmed on a periodic and event-driven basis by comparison of the model predictions with the known values of the reference samples or reference analytical procedure results. This confirmatory testing helps to ensure that the calibration model continues to perform as expected. Examples of events that could trigger confirmatory testing include new known process variability, unexpected process events or scheduled instrument maintenance. ICH Q14 Guideline Monitoring of the model can be used to trigger model rebuilding (recalibration) as a part of continual improvement. In general, the same considerations hold as for the original model building and internal testing. Based on the cause of the model update (e.g., a process shift), new data may need to be included and old non-relevant data may be taken out. Once the new calibration model is established, the updated analytical procedure can be validated against the same performance criteria as the ones included in the original model. Aspects that are not expected to change from the model update may not need to be evaluated (e.g., specificity). *[Figure 3: Multivariate (MV) model lifecycle]* The multivariate model lifecycle (Figure 3) is iterative and can be broken down into 3 major components: model establishment, routine use and model maintenance. The choice of a multivariate model is based on the analytical procedure requirements and the measurement technology selected. Prior to model development, the performance factors for the model are defined, including the underlying model assumptions and desired ranges for model applicability. An initial risk assessment can be valuable to understand potential sources of variability in the materials and process that could affect the model performance and therefore should be considered during the model calibration. Model development, including calibration and internal testing, follows the considerations outlined in this chapter. Once the model is developed, it is validated using independent data not previously used in the calibration set. The last step in model establishment is development of a multivariate model maintenance plan, which includes the procedures and limits for outlier diagnostics, and defines the frequency and circumstances for confirmatory testing, if needed. ICH Q14 Guideline Routine analysis of the multivariate analytical procedure typically includes monitoring the appropriateness of every measurement using outlier diagnostics. Model reassessment can be triggered by failure of confirmatory testing or outlier diagnostics to meet the predefined criteria, or from data trending indicating potential unacceptable performance of the model, the process or the materials being measured (examples of multivariate model lifecycle components are provided in Annex B). Model reassessment is performed within the PQS and utilises knowledge management and risk assessment. If unacceptable performance is identified, model development and revalidation may be needed, for example, to add samples into the calibration set and remove those that are no longer relevant. In some cases, the model may be performing appropriately, but additional experience may identify the need to modify the model maintenance plan. In other cases, the identified unacceptable performance could be related to the measurement system (e.g., a misaligned sample interface) and no model update would be needed. The dashed arrows in Figure. 3 illustrate reintroduction into the lifecycle flow based on the potential outcomes of the model reassessment. 9. DEVELOPMENT OF ANALYTICAL PROCEDURES FOR REAL TIME RELEASE TESTING: ADDITIONAL CONSIDERATIONS Real Time Release Testing (RTRT) is the ability to evaluate and ensure the quality of in-process and/or final product based on process data, which typically include a valid combination of measured material attributes and process controls (ICH Q8). RTRT measurements work in conjunction with all elements of the product control strategy (e.g., process monitoring or in- process controls) to ensure product quality. RTRT can be applied to drug substances, intermediates and drug products. RTRT can be based on an appropriate combination of one or more process measurements and/or material attributes to provide a value for one or more CQAs and should be specific for those CQAs. The relationship between the RTRT approach and the CQAs, as well as acceptance criteria, should be fully justified. An RTRT analytical procedure should be validated as recommended in ICH Q2 and it should be demonstrated that the process measurements have appropriate specificity for the targeted quality attribute. Sampling and the sample interface are important considerations when designing any on-line or in-line analytical procedure, including those used for RTRT. The measurement point(s) should be chosen to be representative of the entire material being processed with the sample duration or amount appropriately chosen (e.g., relative to a unit dose). Additionally, the sample interface should remain consistent over the duration of manufacturing and should be robust to expected processing and environmental variations. The RTRT approach should be included in the product specification (ICH-Endorsed Guide for ICH Q8/Q9/Q10 Implementation). In accordance with ICH Q6A Specifications: Test Procedures and Acceptance Criteria For New Drug Substances and New Drug Products: Chemical Substances and ICH Q6B Specifications: Test Procedures and Acceptance Criteria For Biotechnological/Biological Products, this includes a reference to the analytical procedure(s) and the related acceptance criteria. Quantitative RTRT results should be expressed in the same units as those for traditional testing. The product specification will typically also include the analytical procedures to be used for off-line testing. If the dossier includes a registered alternative control strategy to RTRT (e.g., traditional end-product testing when process analytics are unavailable), the related analytical procedures and when they would be applied should also be included in the product specifications. ICH Q14 Guideline 10. SUBMISSION OF ANALYTICAL PROCEDURE RELATED INFORMATION ### 10.1 General Regulatory Considerations and Documentation The analytical procedure description(s) should be included in the ICH M4Q CTD section 3.2.S.4.2 for drug substance or section 3.2.P.5.2 for drug product. Validation data and supportive information needed to justify the analytical procedure control strategy should be included in the CTD section 3.2.S.4.3 for drug substance or section 3.2.P.5.3 for drug product. Other analytical procedures used as part of the control strategy should be included in relevant CTD sections (e.g., 3.2.S.2, 3.2.P.3 and 3.2.P.4). The analytical procedure should describe the steps in sufficient detail for a skilled analyst to perform the analysis (including SST) as elaborated in Chapter 6. Submission of validation data should reflect the guidance provided in ICH Q2. The performance criteria used in the validation study should be included in the submission. In some cases, depending on the intended purpose (e.g., dissolution testing) and/or the selected technique, it may be appropriate to submit development data as justification. Where ECs are proposed for analytical procedures as elaborated in Chapter 6, the ECs should be clearly differentiated from supportive information. Additional development and validation information can be included in sections 3.2.S.4.3 and 3.2.P.5.3 to justify ECs and their reporting categories. When other lifecycle management elements as described in ICH Q12 are included in the submission, the applicant should follow the principles described in ICH Q12 and Chapter 7 of this document. ### 10.2 Documentation for the Enhanced Approach If the approach to development leads to the incorporation of enhanced elements into the analytical procedure control strategy, then these should be justified. Performance characteristics and acceptance criteria (e.g., described in an ATP) and other elements of the enhanced approach (e.g., MODRs or PARs), should be described in the dossier sections for analytical procedure description (e.g., 3.2.S.4.2 and 3.2.P.5.2). If ECs are proposed, then these should also be included in the analytical procedure description, accompanied by supportive information. The use of the enhanced approach should not lead to providing a less detailed description of analytical procedures in a regulatory submission. If ECs and related reporting categories are proposed, risk-based categorisation of changes and corresponding reporting categories should be included in the submission. Justification should be given for parameters that are ECs and those that are not ECs, as appropriate (see Chapter 6). Appropriate information from analytical procedure risk assessment and development studies to support the proposed lifecycle management strategy should be summarised and submitted in the regulatory submission sections for analytical procedure validation (e.g., 3.2.S.4.3 and 3.2.P.5.3). ### 10.3 Documentation for Multivariate Analytical Procedures Development information related to multivariate analytical procedures should be provided commensurate with the level of impact of the model (ICH-Endorsed Guide for ICH Q8/Q9/Q10 Implementation). The process development section of the dossier (e.g., 3.2.S.2.6 or 3.2.P.2) should include the model development information for multivariate models used as part of manufacturing development studies or for in-process controls or tests. Supportive development information for RTRT multivariate models can be included in either the appropriate analytical procedure validation or process development section. Validation information for analytical procedures used for release of drug substance or drug product, including RTRT, should be included in the validation information section of the ICH Q14 Guideline dossier (e.g., 3.2.S.4.3 or 3.2.P.5.3). Additionally, these sections should include validation information on analytical procedures used as reference analytical procedures. The model development, calibration and validation information can be included directly in the CTD section or in an appended document. For multivariate models used as part of drug substance or drug product specifications, including RTRT approaches, the description of the validation approach and results should include: • Description of the validation set with independent samples; • The performance criteria to be met during validation of the multivariate model; • Evaluation of the model validation results against the performance criteria; • Discussion of the relationship between the model performance criteria and the attribute specification limits; • High level overview of the PQS elements for model monitoring and maintenance, such as diagnostic tools for determining the appropriateness of the sample data for the model and the approach taken when outliers are identified. The description of the analytical procedure used for RTRT should be provided in the CTD section 3.2.S.4.2 for drug substance or section 3.2.P.5.2 for drug product and typically includes: • The property or attribute of interest to be determined by the multivariate analytical procedure and the desired quantitative ranges or limits; • A description of the measurement principle and pertinent instrument operating parameters (e.g., sample presentation, sample interrogation time and measurement frequency); • An overview of how the multivariate model calibration data are obtained (e.g., sample preparation approach, reference analytical procedure); • The type of multivariate model; • A description of reference analytical procedure or high-level description of prepared reference samples; • Any calculations needed to adjust the model output into the reported value. Additionally, section 3.2.S.4.2 for drug substance or section 3.2.P.5.2 for drug product should include description of any analytical procedures that are part of a registered alternative control strategy to RTRT. Information on validation of these alternative analytical procedures should be included in the validation information section of the dossier (e.g., 3.2.S.4.3 or 3.2.P.5.3). 11. GLOSSARY ACCURACY The accuracy of an analytical procedure expresses the closeness of agreement between the value which is accepted either as a conventional true value or as an accepted reference value and the value or set of values measured. (ICH Q2) ANALYTICAL PROCEDURE The analytical procedure refers to the way of performing the analysis. The analytical procedure should describe in sufficient detail the steps necessary to perform each analytical test. (ICH Q2) ICH Q14 Guideline ANALYTICAL PROCEDURE ATTRIBUTE A technology specific property that should be within an appropriate limit, range, or distribution to ensure the desired quality of the measured result. For example, attributes for chromatography measurements may include peak symmetry factor and resolution. (ICH Q14) ANALYTICAL PROCEDURE CONTROL STRATEGY A planned set of controls derived from current analytical procedure understanding that ensures the analytical procedure performance and the quality of the measured result. (ICH Q14) ANALYTICAL PROCEDURE PARAMETER Any analytical factor (including reagent quality) or analytical procedure operational condition that can be varied continuously (e.g., flow rate) or specified at controllable, unique levels. (ICH Q14) ANALYTICAL PROCEDURE VALIDATION STRATEGY An analytical procedure validation strategy describes the selection of analytical procedure performance characteristics for validation. In the strategy, data gathered during development studies and system suitability tests (SSTs) can be applied to validation and an appropriate set of validation tests can be predefined. (ICH Q14) ANALYTICAL TARGET PROFILE (ATP) A prospective summary of the performance characteristics describing the intended purpose and the anticipated performance criteria of an analytical measurement. (ICH Q14) CALIBRATION MODEL A model based on analytical measurements of known samples that relates the input data to a value for the property of interest (i.e., the model output). (ICH Q2) CONTROL STRATEGY A planned set of controls, derived from current product and process understanding, that assures process performance and product quality. The controls can include parameters and attributes related to drug substance and drug product materials and components, facility and equipment operating conditions, in-process controls, finished product specifications, and the associated methods and frequency of monitoring and control. (ICH Q10) CRITICAL QUALITY ATTRIBUTE (CQA) A physical, chemical, biological or microbiological property or characteristic that should be within an appropriate limit, range or distribution to ensure the desired product quality. (ICH Q8) CTD Common Technical Document. (ICH M4Q) DoE Design of Experiments. ICH Q14 Guideline ESTABLISHED CONDITIONS (ECs) ECs are legally binding information considered necessary to assure product quality. As a consequence, any change to ECs necessitates a submission to the regulatory authority. (ICH Q12) INTERMEDIATE PRECISION Intermediate precision expresses intra-laboratory variations. Factors to be considered should include potential sources of variability, for example, different days, different environmental conditions, different analysts and different equipment. (ICH Q2) KNOWLEDGE MANAGEMENT A systematic approach to acquiring, analysing, storing and disseminating information related to products, manufacturing processes and components. (ICH Q10) METHOD OPERABLE DESIGN REGION (MODR) A combination of analytical procedure parameter ranges within which the analytical procedure performance criteria are fulfilled and the quality of the measured result is assured. (ICH Q14) ONGOING MONITORING The collection and evaluation of analytical procedure performance data to ensure the quality of measured results throughout the analytical procedure lifecycle. (ICH Q14) PACMP Post-Approval Change Management Protocol. (ICH Q12) PERFORMANCE CHARACTERISTIC A technology independent description of a characteristic that ensures the quality of the measured result. Typically, accuracy, precision, specificity/selectivity and range may be considered. Previous ICH Q2 versions referred to this as VALIDATION CHARACTERISTIC. (ICH Q2) PERFORMANCE CRITERION An acceptance criterion describing a numerical range, limit or desired state to ensure the quality of the measured result for a given performance characteristic. (ICH Q14) PLATFORM ANALYTICAL PROCEDURE An analytical procedure that is suitable to test quality attributes of different products without significant change to its operational conditions, system suitability and reporting structure. This type of analytical procedure can be used to analyse molecules that are sufficiently alike with respect to the attributes that the platform analytical procedure is intended to measure. (ICH Q2) PRECISION The precision of an analytical procedure expresses the closeness of agreement (degree of scatter) between a series of measurements obtained from multiple samplings of the same homogeneous sample under the prescribed conditions. Precision can be considered at three levels: repeatability, intermediate precision and reproducibility. The precision of an analytical procedure is usually expressed as the variance, standard deviation or coefficient of variation of a series of measurements. (ICH Q2) ICH Q14 Guideline PROVEN ACCEPTABLE RANGE FOR ANALYTICAL PROCEDURES (PAR) A characterised range of an analytical procedure parameter for which operation within this range, while keeping other parameters constant, will result in an analytical measurement meeting relevant performance criteria. (ICH Q14) QUALITY RISK MANAGEMENT (QRM) A systematic process for the assessment, control, communication and review of risks to the quality of the drug (medicinal) product across the product lifecycle. (ICH Q9) RANGE The range of an analytical procedure is the interval between the lowest and the highest results in which the analytical procedure has a suitable level of precision, accuracy and response. (ICH Q2) REPORTABLE RANGE The reportable range of an analytical procedure includes all values from the lowest to the highest reportable result for which there is a suitable level of precision and accuracy. Typically, the reportable range is given in the same unit as the specification acceptance criterion. (ICH Q2) WORKING RANGE A working range corresponds to the lowest and the highest level of the quality attribute to be measured (e.g., content or purity) as presented to the analytical instrument and for which the analytical procedure provides reliable results. (ICH Q2) REAL TIME RELEASE TESTING (RTRT) The ability to evaluate and ensure the quality of the in-process and/or final product based on process data, which typically include a valid combination of measured material attributes and process controls. (ICH Q8) REFERENCE MATERIAL A suitably characterised material, sufficiently homogeneous and stable with regard to one or more defined attributes, which has been established to be fit for the intended purpose. Reference materials may include national/international reference standards, pharmacopoeial reference standards, or in-house primary/secondary reference materials. (ICH Q2) REPEATABILITY Repeatability expresses the precision under the same operating conditions over a short interval of time. Repeatability is also termed intra-assay precision. (ICH Q2) REPORTABLE RESULT The result as generated by the analytical procedure after calculation or processing and applying the described sample replication. (ICH Q2) REPRODUCIBILITY Reproducibility expresses the precision between laboratories (e.g., inter-laboratory studies, usually applied to standardisation of methodology). (ICH Q2) ICH Q14 Guideline RESPONSE The response of an analytical procedure is its ability (within a given range) to obtain a signal which is effectively related to the concentration (amount) or activity of analyte in the sample by some known mathematical function. (ICH Q2) REVALIDATION Demonstration that an analytical procedure is still fit for the intended purpose after a change to the product, process or the analytical procedure itself. Revalidation can involve all (full revalidation) or a subset (partial revalidation) of performance characteristics. (ICH Q2) ROBUSTNESS The robustness of an analytical procedure is a measure of its capacity to meet the expected performance criteria during normal use. Robustness is tested by deliberate variations of analytical procedure parameters. (ICH Q14) SAMPLE SUITABILITY ASSESSMENT A sample or sample preparation is considered suitable if the measurement response on the sample satisfies pre-defined acceptance criteria for the analytical procedure attributes that have been developed for the validated analytical procedure. (ICH Q14) SPECIFICITY/SELECTIVITY Specificity and selectivity are both terms to describe the extent to which other substances interfere with the determination of an analyte according to a given analytical procedure. Specificity is typically used to describe the ultimate state, measuring unequivocally a desired analyte. Selectivity is a relative term to describe the extent to which particular analytes in mixtures or matrices can be measured without interferences from other components with similar behaviour. (ICH Q2) SYSTEM SUITABILITY TEST (SST) System suitability tests are developed and used to verify that the measurement system and the analytical operations associated with the analytical procedure are fit for the intended purpose and increase the detectability of unacceptable performance. (ICH Q14) VALIDATION STUDY An evaluation of prior knowledge, data or deliberate experiments (i.e., validation tests) to determine the suitability of an analytical procedure for the intended purpose. (ICH Q2) VALIDATION TEST Validation tests are deliberate experiments designed to authenticate the suitability of an analytical procedure for the intended purpose. (ICH Q2) MULTIVARIATE GLOSSARY CALIBRATION SET A set of data with matched known characteristics and measured analytical results. (ICH Q14) ICH Q14 Guideline DATA TRANSFORMATION Mathematical operation on model input data to assume better correlation with the output data and to simplify the model structure. (ICH Q14) INDEPENDENT SAMPLE Independent samples are samples not included in the calibration set of a multivariate model. Independent samples can come from the same batch from which calibration samples are selected. (ICH Q2) INTERNAL TESTING Internal testing is a process of checking if unique samples processed by the model yield the correct predictions (qualitative or quantitative). Internal testing serves as means to establish the optimal number of latent variables, estimate the standard error and detect potential outliers. (ICH Q2) INTERNAL TEST SET A set of data obtained from samples that have physical and chemical characteristics that span a range of variabilities similar to the samples used to construct the calibration set. (ICH Q14) LATENT VARIABLES Mathematically derived variables that are directly related to measured variables and are used in further processing. (ICH Q2) MODEL MAINTENANCE The process of ensuring continued model performance over the lifecycle of a multivariate model, which often includes outlier diagnostics and resulting actions for model redevelopment or change in the maintenance plans. (ICH Q14) MODEL VALIDATION The process of determining the suitability of a model by challenging it with independent test data and comparing the results against predetermined performance criteria. (ICH Q2) MULTIVARIATE ANALYTICAL PROCEDURE An analytical procedure where a result is determined through a multivariate calibration model utilising more than one input variable. (ICH Q2) OUTLIER DIAGNOSTIC Tests that can identify unusual or atypical data in a multivariate analytical procedure. (ICH Q14) REFERENCE ANALYTICAL PROCEDURE A separate analytical procedure used to obtain the reference values of the calibration and validation samples for a multivariate analytical procedure. (ICH Q2) REFERENCE SAMPLE A sample representative of the test sample with a known value for the property of interest, used for calibration. (ICH Q14) ICH Q14 Guideline VALIDATION SET A set of data used to give an independent assessment of the performance of the calibration model. (ICH Q2) 12. REFERENCES ICH Q2 Validation of Analytical Procedures ICH Q6A Specifications: Test Procedures and Acceptance Criteria For New Drug Substances and New Drug Products: Chemical Substances ICH Q6B Specifications: Test Procedures and Acceptance Criteria For Biotechnological/Biological Products ICH Q8 Pharmaceutical Development ICH Q9 Quality Risk Management ICH Q10 Pharmaceutical Quality System ICH Q11 Development and Manufacture of Drug Substances ICH Q12 Technical and Regulatory Considerations for Pharmaceutical Product Lifecycle Management ICH M4Q The Common Technical Document For The Registration of Pharmaceuticals For Human Use ICH-Endorsed Guide for ICH Q8/Q9/Q10 Implementation ICH Q14 Guideline 13. ANNEX ### 13.1 Annex A: Examples of application of ICH Q14 principles The examples provided in this Annex are for illustrative purposes only. Other approaches are possible. They suggest how the concepts described in ICH Q14 could be applied and should not be used as a template or the sole basis for a regulatory submission. The examples have been created to illustrate: • How analytical procedure performance characteristics, derived from the product context and knowledge, could be summarised in an ATP; • How performance characteristics described in the ATP could be applied to select a suitable analytical technology, guide the development of an analytical procedure and help define the analytical procedure control strategy; • How to identify ECs for analytical procedures developed using elements of the enhanced approach; • How QRM and the adherence to associated criteria for relevant performance characteristics and/or the subsequent execution of a bridging study can ensure the post-change quality of the measured result and help to justify the respective reporting categories for ECs and the post approval change management of analytical procedures. As described in Chapter 4 of ICH Q14, QRM can be used to evaluate the impact of prospective changes for analytical procedures. The list below describes examples of risk factors and risk reduction measures to identify the risks associated with the changes to an analytical procedure. The outcome of the risk assessment (risk level: high, medium or low) feeds into the design and extent of the studies needed to support the change. Selected Risk (risk factors) • Relevance of the test • Potential clinical impact of the measured attribute (efficacy, safety, pharmacokinetics and immunogenicity), e.g., controlling CQA vs. non CQA; • Extent of knowledge of the attribute; • Attribute ensured by other elements of the control strategy (testing or process control); • Complexity of the technology • Platform technologies; • Novel vs. established technology (e.g., in pharmacopoeias); • Several attributes reported as a sum (e.g., charge variants for large molecules); • Biological assays, cell-based assays, immunochemical assays; • Multi-attribute analytical procedure; • Multivariate analytical procedure; • Extent of the change • Change of one or several parameters outside the already proven acceptable ranges; • Change of the analytical procedure within existing analytical procedure performance characteristics and associated criteria; • Change to a new analytical procedure using a different technology; • Change to analytical procedure performance criteria (e.g., due to tightening a specification limit). ICH Q14 Guideline Risk reduction Risk reduction is defined in ICH Q9 as actions taken to lessen the probability of occurrence of harm and the severity of that harm. Different kinds of knowledge can lead to reduction of risk, for example: • Product and process knowledge - Knowledge about quality attributes of the drug substance/drug product and acceptable ranges of CQAs; - Well justified analytical procedure performance criteria cover/link to CQAs and their acceptable ranges; - Evidence to control the CQAs through the process parameter settings - Knowledge of the degradation pathways demonstrated by the analysis of relevant stressed samples; - Other product knowledge (e.g., impurity profile, particle size and distribution); • Analytical procedure understanding and analytical procedure control strategy - Knowledge about analytical procedure parameters and their impact on measurement performance; - Proven analytical procedure robustness, e.g., harmonised procedures (compendial tests); - Enhanced analytical procedure understanding (e.g., DoE studies) supporting justification of acceptable ranges (e.g., PAR, MODR); - Other knowledge from development of analytical procedure; - System Suitability Test ensures relevant analytical procedure attributes; - Ongoing monitoring of analytical procedure output; - Clear link between signal and CQA to be measured (e.g., peak characterisation available, specificity); • Bridging strategy for changes to analytical procedures - Availability of reference material, relevant historical and or stressed samples to support analytical procedure output assessment against performance criteria (demonstrated ability to control the CQA); - Comparison to output of previous analytical procedure (understanding and acceptance of risk for potential differences); - Demonstrated understanding of risks associated with parameter changes and potential interactions with other parameters; - Prior experience with similar changes, analytes or technologies including platform analytical procedures. ICH Q14 Guideline #### 13.1.1 Measurement of Stereoisomers as Specific Process Related Impurities in a Small Molecule Drug Substance (DS) Introduction and Background “Sakuratinib Maleate” is a small molecule DS with multiple chiral centres. The chirality of the molecule, its degradation pathway and the impurities are well characterised. From this knowledge and the established manufacturing process controls, the six stereoisomers (Impurity A-F) were found to be potentially present in the final product. Table 1: Analytical target profile Intended Purpose Quantitation of the six stereoisomers A-F in Sakuratinib Maleate DS for release testing Link to CQA (Stereoisomeric Purity) The analytical procedure should allow for the quantitation of the individual stereoisomers A-F and determination of the total sum to verify the CQA Stereoisomeric Purity ≥99.0% Characteristics of the Reportable Results Performance Characteristics Acceptance Criteria Rationale Accuracy 80–120% average recovery of spiked DS with Impurities A-E (specified at NMT 0.1% each) 90–110% average recovery of spiked DS with Impurity F (specified at NMT 0.5%) For example, at a specification level of 0.1%, 20% bias would lead to a variation of the analytical result of 0.02%, which was found acceptable for a release decision. In a similar fashion, values for precision were derived. The recovery criteria for accuracy were set with respect to the reported result and taking into consideration any correction or response factors Precision Intermediate Precision RSD: Impurities A–E ≤15% Impurity F ≤10% Specificity Analytical procedure should be able to quantitate impurities A–F in presence of other likely process related substances or DS degradation products with an acceptable bias of not more than 0.02% Potential interference with quantitation of specified impurities by other regular components in the sample Reportable Range Impurities A–E: at least 0.05–0.12% Impurity F: at least 0.05–0.6% Reporting threshold to 120% of specification limit Technology Selection Multiple analytical technologies are available for the separation of stereoisomers. In this example, HPLC was chosen because development studies showed good potential for separation of stereoisomers. As detection mode, UV detection was selected as it was known that the molecule had sufficient UV absorption properties. Analytical Procedure Development The chiral HPLC procedure for quantitation of stereoisomers was developed using enhanced principles. Below is a summary of the activities conducted during enhanced development. • An understanding of the chemistry, process, and impurities that have potential to be present in the drug substance was established; • Reference materials were made available for development and validation; ICH Q14 Guideline • Conducted risk assessment and evaluating prior knowledge to identify the analytical procedure parameters that can impact performance of the procedure; • Conducted modelling and multi-variate experiments including robustness testing to explore ranges and interactions between identified analytical procedure parameters; • Defined analytical procedure control strategy based on procedure understanding including set-points for relevant analytical procedure parameters and SST. Analytical Procedure For the purpose of this example, a summary of the analytical procedure is provided below. This does not reflect the entirety of the analytical procedure description in the dossier. Table 2: Summary of the analytical procedure description Column Chiral Column, Amylose tris-(3,5-dimethylphenylcarbamate), immobilised on porous, spherical, silica particles, 4.6 mm ID x 250 mm, 3 µm Mobile Phase n-hexane / ethanol / TFA (80/20/0.1) Flow Rate 1 mL/min Column temperature 30°C Detection UV 214 nm Injection Volume 5 µL Standard/Sample Concentration 1.0 mg/mL System Suitability Tests Controlled Parameters Resolution between critical peak pair: DS Main Peak and Impurity D ≥ 2.0 Column, Temperature*, Mobile Phase, Flow Rate S/N at QL; DS at 0.05% >10 Injection Volume, Column, Mobile Phase, Standard/Sample Concentration, Detection Wavelength Repeatability of injection of DS at 0.5% level ≤ 5% Injection Volume, Mobile Phase * For example, the retention time models built from data collected during analytical procedure development screens were used to assess the robustness of temperature and other parameters, that could potentially affect the performance characteristics (e.g., specificity). The in silico robustness was verified experimentally by confirming resolution at the centre point and design points that generated the minimum and maximum main peak retention time. Analytical Procedure Validation After the analytical procedure development was finalised and the analytical procedure control strategy established, a validation study was planned and completed according to the ICH Q2 guideline. Description of Established Conditions (ECs), Reporting Categories, and Justifications The applicant proposed and justified established conditions and reporting categories, as part of the submission. For the purpose of this example, Table 3 describes the proposed ECs, their proposed reporting categories and examples of parameters that are not ECs. Note: The extent of ECs and associated reporting categories listed in this table depend on the extent of knowledge gained, information and justification provided in the dossier. The dossier is subject to regulatory review. The information provided in this example is only part of the knowledge available that will be submitted and is provided for illustrative purposes only. The extent of ECs (EC or not EC designation), actual reporting categories, and data requirements ICH Q14 Guideline may differ by region. Depending on the nature and extent of the change (e.g., change to a different technology), a PACMP may be required. Table 3: Evaluated risk, proposed established conditions and proposed reporting categories Established Condition Overall Risk Category Proposed Reporting Category1) Comment Performance Characteristics and Criteria as described in the ATP: Accuracy, Precision, Specificity, Range (see Annex A , Table 1) High PA The performance characteristics and criteria ensure the quality of the reportable result and link to the CQA. If widening of the performance criteria is necessary, it will be reported as PA Technology: Chiral Liquid Chromatography Suitable chiral separation technique to meet performance characteristics defined in ATP Medium NM A technique that meets the performance characteristics and criteria ensures the quality of the reportable result and link to the CQA. There is a strong understanding between product knowledge, intended purpose, and the analytical procedure performance established to enable the design of future bridging studies. A change resulting in a widening of the specification acceptance criteria might require a higher reporting category System Suitability Test and parameter- control relationship (see Annex A, Table 2) Medium NL/NM SST was developed for the LC procedure based on a risk analysis and ensures adherence to the performance characteristics and criteria. Control relationships were established through prior knowledge (general principles of technique) and during procedure development. If the SST criteria are widened the reporting category would be higher LC Column: Amylose tris-(3,5- dimethylphenylcarbamate), immobilised on porous, spherical silica particles Mobile Phase Components: n-Hexane, Method of detection: UV 214 nm Low NL/NM The LC column, mobile phase components and mode of detection are the main parameters, defining the separation mechanism and detection. Changing these parameters may result in the need to adapt the SST The other analytical procedure parameters defined as ECs are omitted for the purpose of this example The following conditions are examples of parameters that are not ECs2): Ratio of mobile phase components: n- Hexane/Ethanol/TFA (80/20/0.1) Instrumental conditions: Temperature: 30°C Column length, packing particle size Low - These parameters are controlled by the SST. Robustness testing supported by modelling was performed at the centre point and the extrema that generated the minimum and maximum main band retention time Preparation of test solutions and reference materials: 1 mg/mL DS in mobile phase Low - The performance over the working range has been demonstrated through the linearity experiments during validation 1) PA: Prior Approval, NM: Notification Moderate; NL: Notification Low (as per ICH Q12 definitions) 2) Depending on the region, some of this information is included in an approval letter ICH Q14 Guideline Change Management and Bridging Strategy The change described below is an example of one that could occur during the lifecycle of a product and analytical procedure. When the product was initially submitted and approved, Supercritical Fluid Chromatography (SFC) was not selected as the analytical technique due to unavailability in the commercial facility. Years after approval, the applicant desires to change the technique to SFC as it is a more environmentally-friendly technology and is now available at the commercial site. For this change, following development of the SFC procedure the applicant will perform a structured risk assessment to evaluate potential impact on the performance characteristics and the link to CQA (stereoisomeric purity) as defined in the ATP. As an outcome of the risk assessment, experimental bridging studies to demonstrate adherence to the performance characteristics and associated criteria will be performed. Validation of the new analytical procedure and comparative analysis of representative samples and reference materials will be performed. The applicant should not implement the new analytical procedure using the predefined reporting category unless adherence to the performance characteristics and associated criteria defined in the ATP is demonstrated during the bridging studies. If the precondition of adherence to the ATP cannot be met, a higher reporting category would apply. The example in Annex A, Figure 1 illustrates a post-approval change in technique as well as the steps an applicant would follow when implementing the change. The information in the table above (ECs and reporting categories) would need to be agreed upon up front with the regulatory authority. ICH Q14 Guideline *[Figure 1: Example of work process of applicant to change an approved analytical]* procedure ICH Q14 Guideline #### 13.1.2 Measurement of Potency for an anti-TNF-alpha Monoclonal Antibody Introduction and Background The example presented refers to the measurement of the relative potency of the drug, in this case an anti-TNF-alpha monoclonal antibody, in drug substance and in drug product at release and for stability testing. Assumptions for the example: • Mode of action: the neutralisation of the biological activity of soluble TNF-alpha by preventing TNF-alpha from binding to the TNF-alpha receptor; • Fc-effector functions are out of scope; • Specification limits for the relative potency: 80% to 125% compared to reference material; • Potency assay to be developed is able to detect a change and/or a shift in potency upon forced degradation. Table 4: Analytical target profile Intended Purpose Measurement of the potency of an anti-TNF-alpha monoclonal antibody in drug substance and in drug product at release and for stability testing. Link to CQA (biological activity) The mode of action of the drug is the neutralisation of the biological activity of soluble TNF-alpha by preventing TNF-alpha from binding to the TNF-alpha receptor. Target acceptance criteria: 80% to 125% relative potency1) Characteristics of the Reportable Result Performance Characteristics Acceptance criteria Rationale Accuracy Accuracy is assessed via a linearity experiment that covers the reportable range. No trend in relative bias is observed over the tested relative potency range The 95% confidence interval of the slope of the fitted regression line between theoretical and measured potency falls within a range of 0.8 to 1.25 The upper and lower 90% confidence interval for the relative bias calculated at each potency level is not more than 20%1) Parameters are assessed based on compendial guidance The acceptance criteria are determined considering the intended purpose of the measurement Selected performance characteristic ensures that the intended analytical procedure delivers the quality of the reportable result Precision Upper 95% confidence interval for the average intermediate precision across levels across the reportable range (95% CI % geometric coefficient of variation) is not more than 20%1) Specificity Analytical procedure is specific for the intended mechanism of action of the active ingredient Critical characteristic of a bioassay to ensure specificity towards the targeted biological activity No interference from relevant process related impurities or matrix components For example, process related and matrix components do not significantly affect the characteristics of the dose response curve Assay is stability indicating i.e., capable of detecting a change in potency and/or a change in the shape of the dose response curve, confirmed using forced degraded samples To ensure that the product remains within specification over its shelf-life Reportable range The potency range is the range that meets accuracy and precision. It should include the specification range (80% to 120% of the specification range in this case corresponding to 64% to 150% for a specification of 80% to 125% relative potency1)) Stated range for which the required accuracy and precision characteristics are demonstrated 1) Individual values are just an example and can be different from product to product. ICH Q14 Guideline Technology Selection Binding assays and cell-based bioassays are suitable technologies for the measurement of the relative potency of an anti-TNF-alpha monoclonal antibody when considering the ATP above. The two assays rely on the binding of the anti-TNF-alpha monoclonal antibody to the soluble TNF-alpha. While the signal of a binding assay directly measures the binding, the cell-based assay may target a later stage event in the signalling cascade. Out of different formats of cell- based assay, the cell-based proliferation assay was chosen as it is widely used and a well characterised cell line was available. Analytical Procedure Development The development of the analytical procedure described has been performed using an enhanced approach and was based on extensive knowledge of the molecule and relative potency assays, considering the following points for example: • Performance characteristics and associated criteria for the analytical procedure defined in the ATP; • Extensive analytical procedure understanding gained from prior knowledge and development studies guided by QRM principles. Factors considered during risk assessment are shown in Annex A, Figure 2: e.g., • The cell and its performance (cell density, cell viability, number of passages); • Stability indicating properties using forced degradation samples; • Robustness evaluation was conducted and its outcome was reflected in the analytical procedure control strategy. *[Figure 2: Ishikawa diagram]* Analytical Procedure For the purpose of this example, a summary of the analytical procedure is provided below. This does not reflect the entirety of the procedure description in the dossier. ICH Q14 Guideline Table 5 Analytical procedure description Unit Operation Description Cell preparation Prepare a suspension of WEHI-164 cells containing 1x106 cells per millilitre, using assay medium containing 2 µg/mL of actinomycin D Reference solution and test solution preparation Included in analytical procedure description in the dossier but not listed in this table Plate preparation Plating cells Absorbance measurement Calculations Solutions & reagents preparation WEHI-164 cells (ATCC), TNF-alpha solution of suitable concentration, assay and culture medium including components and concentrations- Actinomycin D, Tetrazolium salt WST-8 Analytical Procedure Control Strategy System suitability test 1. The dose-response curve obtained for the reference standard curve corresponds to a sigmoid curve with upper and lower plateaus corresponding to ‘cell only control’ and ‘cell + TNF-alpha control’, respectively 2. The dose-response curve obtained for the test sample corresponds to a sigmoid curve with upper and lower plateaus corresponding to ‘cell only control’ and ‘cell treated with TNF-alpha control’, respectively. 3. The coefficient of determination calculated for each standard curve (r2) is not less than 0.97 * 4. Maximum value (cell only) to minimum value (TNF-alpha control) ratio: minimum 3.0* Sample suitability assessment Assessment of similarity/parallelism: - The upper asymptote ratio (Astd/Atest): 0.8–1.2* - The lower asymptote ratio (Dstd/Dtest): 0.8–1.2* - The Hill slope ratio (Bstd/Btest): 0.8–1.2* - The upper to lower asymptote ratio ((D–A)std/(D–A)test): 0.8–1.2* * The ways of assessing of similarity/parallelism as well as individual values are just examples and can be different from product to product. Analytical Procedure Validation After the analytical procedure development was finalised and the analytical procedure control strategy established, a validation study was planned and completed according to the recommendations in ICH Q2. Description of Established Conditions, Reporting Categories, and Justifications The applicant proposed and justified established conditions and reporting categories, as part of the submission. For the purpose of this example, Annex A Table 6 describes a portion of the proposed ECs, their proposed reporting and an example of a parameter that is not an EC. Note: The extent of ECs and associated reporting categories listed in this table depend on the extent of knowledge gained, information and justification provided in the dossier. The dossier is subject to regulatory review. The information provided in this example is only part of the knowledge available that will be submitted and is provided for illustrative purposes only. The extent of ECs (EC or not EC designation), actual reporting categories, and data requirements may differ by region. Depending on the nature and extent of the change (e.g., change to a different technology), a PACMP may be required. ICH Q14 Guideline Table 6: Evaluated risk, proposed established conditions and proposed reporting categories Established condition Overall Risk Category Proposed Reporting Category1) Comment Performance characteristics and associated criteria as defined in the ATP (Annex A Table 4) High PA The performance characteristics and criteria ensure the quality of the reportable result and link to the CQA. Widening of performance characteristics and criteria could have an impact on the control of the CQA Technology (principle) Cell Based Assay High or Medium PA or NM Adherence to performance characteristics and criteria ensured by control strategy and defined bridging strategy (see below) to assess impact of changes Change would be reported as Notification Moderate if no impact of the change on the specification acceptance criteria and as Prior Approval if there is an impact on the specification acceptance criteria Analytical procedure control strategy elements (SST 1-4, sample suitability assessment) System suitability test (see Annex A Table 5) Medium NM2) Performance of the analytical procedure is ensured by • Direct control of individual analytical procedure steps through analytical procedure control strategy elements listed in Annex A Table 5 (and the dossier) • Defined analytical procedure control strategy elements which ensures the adherence to the ATP • Adherence to the performance characteristics and criteria after a change of analytical procedure control strategy elements If assurance of performance of the analytical procedure cannot be demonstrated, the change needs to be reported as Prior Approval Sample suitability assessment (see Annex A Table 5) Medium NM2) Cell Preparation Cell line: WEHI-164 cells (ATCC) Medium NM Based on demonstrated understanding of the mode of action (link to CQA) the suitability of the responsive cell line will be confirmed by responding to the TNF-alpha (survival of the cell in presence of the drug and cell death without drug) Adherence to ATP ensured by control strategy and defined bridging strategy (see below) to assess impact of changes System suitability test ensures the suitability of the cell line and its performance (number of passages, confluency, cell counting, cell viability, signal amplitude, shape of the response curve) ICH Q14 Guideline Established condition Overall Risk Category Proposed Reporting Category1) Comment Preparation of cells: sub culturing Low NL Sufficient cell performance to detect changes in the quality of the drug is ensured by: • System suitability covers the suitability of the cell preparation (number of passages, confluency, cell counting, cell viability, signal amplitude, shape of the response curve) • Changes in cell metabolism that impact performance of the analytical procedure and link to CQA will be detected • Changes that lead to insufficient cell performance will not be implemented as they could have an impact on the defined performance characteristics and would require prior approval Analytical procedure control strategy ensures adherence to performance characteristics and criteria. The extent of the bridging study will depend on the extent of the change Medium composition: RPMI 1640, L-glutamine, heat-inactivated foetal bovine serum, and a suitable antibiotic Low NL Preparation of a suspension of WEHI-164 cells containing 1x106 cells per millilitre, using assay medium containing 2 µg/mL of actinomycin D. Low NL The other analytical procedure parameters defined as ECs are omitted for the purpose of this example The following is an example of a parameter that is not an EC: Plating format Low - No impact on assay output based on development data 1) PA: Prior Approval, NM: Notification Moderate; NL: Notification Low (as per ICH Q12 definitions) 2) Based on regional requirements the proposed reporting category may need to be elevated to PA Change Assessment and Bridging Strategy For every change, the applicant will perform a risk assessment to evaluate potential impact on the performance characteristics and the link to CQA (biological activity) as defined in the respective ATP. The outcome of the risk assessment informs the extent of the bridging studies used to demonstrate adherence to the performance characteristics and associated criteria. These can include, if necessary, full or partial revalidation of the analytical procedure performance characteristics affected by the change and/or comparative analysis of representative samples and reference material. The applicant should not implement the new analytical procedure using the predefined reporting category unless adherence to the performance characteristics and associated criteria defined in the ATP are demonstrated during the bridging studies. If the precondition of adherence to the ATP cannot be met, a higher reporting category would apply. The example in Annex A Figure 3 illustrates a post-approval change in the cell preparation from subculture to ready to use cells and includes the steps an applicant would follow when actually implementing the change. The ECs and reporting categories (see Annex A Table 6) would need to be proposed following ICH Q14 Figure 2 and agreed up front with the regulatory authority. ICH Q14 Guideline *[Figure 3: Example of work process of applicant to change an approved analytical]* procedure ICH Q14 Guideline ### 13.2 Annex B: Example of multivariate model lifecycle components Example 1 Example 2 Example 3 Model Description On-line NIR to determine blending ranges to achieve blend uniformity during development Measurement of Content Uniformity and Assay of uncoated tablets by NIR used for product release Glucose Raman model used for qualitative identification testing on incoming raw material release for GMP use Model Category - Low Impact Model Category - High Impact Model Category - High impact User requirements Defined model requirements (e.g., ATP) Defined model requirements (e.g., ATP) Risk Assessment Initial assessment based on existing knowledge, laboratory and pilot studies, or DoE, as appropriate Formal risk assessment based on knowledge gained during initial development Formal risk assessment with knowledge gained during initial development Model Development - Calibration Scientifically sound approach based on laboratory and pilot data and previous experience Formal design-based approach (e.g., DoE) covering appropriate ranges of relevant variability sources with established acceptance criteria that are suitable for the intended purpose Formal design-based approach covering appropriate ranges of relevant variability sources (raw material, lots, packaging, instrument-to-instrument, user, software limitation) with established acceptance criteria that are suitable for the intended purpose. Establish an identification threshold that has the same probability of detection as the existing analytical procedure and a suitable alternative analytical procedure should the Raman analytical procedure fail Validation Assess specificity and robustness, optionally assess linearity and/or precision Full validation covering applicable performance characteristics across reportable ranges with established acceptance criteria (ICH Q2) Full validation covering applicable performance characteristics across reportable ranges with established acceptance criteria (ICH Q2). Include establishing suitable comparability of Raman procedure to existing analytical procedure for release (can be reference analytical procedure) Performance Monitoring Routine monitoring - maintain data sources (instruments), automation connectivity, and data integrity Routine monitoring - maintain data sources (instruments), automation connectivity, and data integrity Routine monitoring - maintain data sources (instruments), automation connectivity, and data integrity Real-time diagnostics - implement initial diagnostics to confirm model performance in real-time Real-time diagnostics - implement routine diagnostics to confirm model performance in real-time Real-time diagnostics - implement routine diagnostics to confirm model performance in real-time Periodic monitoring - if applicable, compare model predicted results to reference analytical procedure at a frequency that is scientifically justified or on an event driven basis as needed Periodic monitoring - compare model predicted results to reference analytical procedure at a frequency that is scientifically justified or on an event driven basis Periodic monitoring - compare model predicted results to reference analytical procedure at a frequency that is scientifically justified or on an event driven basis Model Maintenance Model Update - updates are common during the process development stage as new experimental data becomes available Model Update - updates should be triggered based on Model Monitoring and Maintenance Strategy Model Update - updates should be triggered based on Model Monitoring and Maintenance Strategy Change Management per PQS Change Management per PQS. with regulatory communication as required Change Management per PQS, with regulatory communication as required --- ### Document: ICH Q8R2 Complete (ICH) # ICH Q8(R2) Pharmaceutical Development: Pharmaceutical Development Guideline === PAGE 1 === INTERNATIONAL CONFERENCE ON HARMONISATION OF TECHNICAL REQUIREMENTS FOR REGISTRATION OF PHARMACEUTICALS FOR HUMAN USE ICH HARMONISED TRIPARTITE GUIDELINE PHARMACEUTICAL DEVELOPMENT Q8(R2) Current Step 4 version dated August 2009 This Guideline has been developed by the appropriate ICH Expert Working Group and has been subject to consultation by the regulatory parties, in accordance with the ICH Process. At Step 4 of the Process the final draft is recommended for adoption to the regulatory bodies of the European Union, Japan and USA. === PAGE 2 === Q8(R2) Document History First Codification History Date Parent Guideline: Pharmaceutical Development Q8 Approval of the Guideline by the Steering Committee under Step 2 and release for public consultation. November 2004 Q8 Approval of the Guideline by the Steering Committee under Step 4 and recommendation for adoption to the three ICH regulatory bodies. November 2005 Annex to the Parent Guideline: Pharmaceutical Development Annex to Q8 Approval of the Annex by the Steering Committee under Step 2 and release for public consultation. November 2007 Annex to Q8 Approval of the Annex by the Steering Committee under Step 4 and recommendation for adoption to the three ICH regulatory bodies. November 2008 Addition of Annex to the Parent Guideline Q8(R1) The parent guideline “Pharmaceutical Development” was recoded Q8(R1) following the addition of the Annex to the parent guideline. November 2008 Current Step 4 version Q8(R2) Corrigendum to titles of “Figure 2a” and “Figure 2b” of “Example 2” on page 23. August 2009 === PAGE 3 === i PHARMACEUTICAL DEVELOPMENT ICH Harmonised Tripartite Guideline TABLE OF CONTENTS PART I: PHARMACEUTICAL DEVELOPMENT 1. INTRODUCTION.................................................................................................. 1 1.1 Objective of the Guideline ........................................................................................1 1.2 Scope .........................................................................................................................1 2. PHARMACEUTICAL DEVELOPMENT............................................................ 1 2.1 Components of the Drug Product.............................................................................3 2.1.1 Drug Substance............................................................................................ 3 2.1.2 Excipients ..................................................................................................... 3 2.2 Drug Product ............................................................................................................3 2.2.1 Formulation Development............................................................................ 3 2.2.2 Overages ....................................................................................................... 4 2.2.3 Physicochemical and Biological Properties ................................................. 4 2.3 Manufacturing Process Development ......................................................................5 2.4 Container Closure System........................................................................................6 2.5 Microbiological Attributes........................................................................................6 2.6 Compatibility............................................................................................................7 3. GLOSSARY ............................................................................................................ 7 PART II: ANNEX TO PHARMACEUTICAL DEVELOPMENT 1. INTRODUCTION.................................................................................................. 9 2. ELEMENTS OF PHARMACEUTICAL DEVELOPMENT ............................ 10 2.1 Quality Target Product Profile...............................................................................10 2.2 Critical Quality Attributes.....................................................................................11 ### 2.3 Risk Assessment: Linking Material Attributes and Process Parameters to Drug Product CQAs .........................................................................................................11 === PAGE 4 === ii 2.4 Design Space...........................................................................................................12 2.4.1 Selection of Variables................................................................................. 12 2.4.2 Describing a Design Space in a Submission.............................................. 12 2.4.3 Unit Operation Design Space(s)................................................................. 12 2.4.4 Relationship of Design Space to Scale and Equipment............................. 12 2.4.5 Design Space Versus Proven Acceptable Ranges ....................................... 13 2.4.6 Design Space and Edge of Failure............................................................. 13 2.5 Control Strategy .....................................................................................................13 2.6 Product Lifecycle Management and Continual Improvement...............................14 3. SUBMISSION OF PHARMACEUTICAL DEVELOPMENT AND RELATED INFORMATION IN COMMON TECHNICAL DOCUMENTS (CTD) FORMAT .............................................................................................................. 14 3.1 Quality Risk Management and Product and Process Development......................15 3.2 Design Space...........................................................................................................15 3.3 Control Strategy .....................................................................................................15 3.4 Drug Substance Related Information ....................................................................15 4. GLOSSARY .......................................................................................................... 16 Appendix 1. Differing Approaches to Pharmaceutical Development ...................................18 Appendix 2. Illustrative Examples........................................................................................19 === PAGE 5 === PART I: PHARMACEUTICAL DEVELOPMENT ICH Harmonised Tripartite Guideline Having reached Step 4 of the ICH Process at the ICH Steering Committee meeting on 10 November 2005, this guideline is recommended for adoption to the three regulatory parties to ICH 1. INTRODUCTION ### 1.1 Objective of the Guideline This guideline describes the suggested contents for the 3.2.P.2 (Pharmaceutical Development) section of a regulatory submission in the ICH M4 Common Technical Document (CTD) format. The Pharmaceutical Development section provides an opportunity to present the knowledge gained through the application of scientific approaches and quality risk management (for definition, see ICH Q9) to the development of a product and its manufacturing process. It is first produced for the original marketing application and can be updated to support new knowledge gained over the lifecycle* of a product. The Pharmaceutical Development section is intended to provide a comprehensive understanding of the product and manufacturing process for reviewers and inspectors. The guideline also indicates areas where the demonstration of greater understanding of pharmaceutical and manufacturing sciences can create a basis for flexible regulatory approaches. The degree of regulatory flexibility is predicated on the level of relevant scientific knowledge provided. ### 1.2 Scope This guideline is intended to provide guidance on the contents of Section 3.2.P.2 (Pharmaceutical Development) for drug products as defined in the scope of Module 3 of the Common Technical Document (ICH guideline M4). The guideline does not apply to contents of submissions for drug products during the clinical research stages of drug development. However, the principles in this guideline are important to consider during those stages as well. This guideline might also be appropriate for other types of products. To determine the applicability of this guideline to a particular type of product, applicants can consult with the appropriate regulatory authorities. 2. PHARMACEUTICAL DEVELOPMENT The aim of pharmaceutical development is to design a quality product and its manufacturing process to consistently deliver the intended performance of the product. The information and knowledge gained from pharmaceutical development studies and manufacturing experience provide scientific understanding to support the establishment of the design space*, specifications, and manufacturing controls. Information from pharmaceutical development studies can be a basis for quality risk management. It is important to recognize that quality* cannot be tested into products; * See Glossary for definition === PAGE 6 === Pharmaceutical Development i.e., quality should be built in by design. Changes in formulation and manufacturing processes during development and lifecycle management should be looked upon as opportunities to gain additional knowledge and further support establishment of the design space. Similarly, inclusion of relevant knowledge gained from experiments giving unexpected results can also be useful. Design space is proposed by the applicant and is subject to regulatory assessment and approval. Working within the design space is not considered as a change. Movement out of the design space is considered to be a change and would normally initiate a regulatory post approval change process. The Pharmaceutical Development section should describe the knowledge that establishes that the type of dosage form selected and the formulation proposed are suitable for the intended use. This section should include sufficient information in each part to provide an understanding of the development of the drug product and its manufacturing process. Summary tables and graphs are encouraged where they add clarity and facilitate review. At a minimum, those aspects of drug substances, excipients, container closure systems, and manufacturing processes that are critical to product quality should be determined and control strategies justified. Critical formulation attributes and process parameters are generally identified through an assessment of the extent to which their variation can have impact on the quality of the drug product. In addition, the applicant can choose to conduct pharmaceutical development studies that can lead to an enhanced knowledge of product performance over a wider range of material attributes, processing options and process parameters. Inclusion of this additional information in this section provides an opportunity to demonstrate a higher degree of understanding of material attributes, manufacturing processes and their controls. This scientific understanding facilitates establishment of an expanded design space. In these situations, opportunities exist to develop more flexible regulatory approaches, for example, to facilitate: • risk-based regulatory decisions (reviews and inspections); • manufacturing process improvements, within the approved design space described in the dossier, without further regulatory review; • reduction of post-approval submissions; • real-time quality control, leading to a reduction of end-product release testing. To realise this flexibility, the applicant should demonstrate an enhanced knowledge of product performance over a range of material attributes, manufacturing process options and process parameters. This understanding can be gained by application of, for example, formal experimental designs*, process analytical technology (PAT)*, and/or prior knowledge. Appropriate use of quality risk management principles can be helpful in prioritising the additional pharmaceutical development studies to collect such knowledge. The design and conduct of pharmaceutical development studies should be consistent with their intended scientific purpose. It should be recognized that the level of * See Glossary for definition === PAGE 7 === Pharmaceutical Development knowledge gained, and not the volume of data, provides the basis for science-based submissions and their regulatory evaluation. ### 2.1 Components of the Drug Product #### 2.1.1 Drug Substance The physicochemical and biological properties of the drug substance that can influence the performance of the drug product and its manufacturability, or were specifically designed into the drug substance (e.g., solid state properties), should be identified and discussed. Examples of physicochemical and biological properties that might need to be examined include solubility, water content, particle size, crystal properties, biological activity, and permeability. These properties could be inter- related and might need to be considered in combination. To evaluate the potential effect of drug substance physicochemical properties on the performance of the drug product, studies on drug product might be warranted. For example, the ICH Q6A Specifications: Test Procedures and Acceptance Criteria for New Drug Substances and New Drug Products: Chemical Substances describes some of the circumstances in which drug product studies are recommended (e.g., Decision Tree #3 and #4 (Part 2)). This approach applies equally for the ICH Q6B Specifications: Test Procedures and Acceptance Criteria for Biotechnology/Biological Products. The knowledge gained from the studies investigating the potential effect of drug substance properties on drug product performance can be used, as appropriate, to justify elements of the drug substance specification (3.2.S.4.5). The compatibility of the drug substance with excipients listed in 3.2.P.1 should be evaluated. For products that contain more than one drug substance, the compatibility of the drug substances with each other should also be evaluated. #### 2.1.2 Excipients The excipients chosen, their concentration, and the characteristics that can influence the drug product performance (e.g., stability, bioavailability) or manufacturability should be discussed relative to the respective function of each excipient. This should include all substances used in the manufacture of the drug product, whether they appear in the finished product or not (e.g., processing aids). Compatibility of excipients with other excipients, where relevant (for example, combination of preservatives in a dual preservative system), should be established. The ability of excipients (e.g., antioxidants, penetration enhancers, disintegrants, release controlling agents) to provide their intended functionality, and to perform throughout the intended drug product shelf life, should also be demonstrated. The information on excipient performance can be used, as appropriate, to justify the choice and quality attributes of the excipient, and to support the justification of the drug product specification (3.2.P.5.6). Information to support the safety of excipients, when appropriate, should be cross- referenced (3.2.P.4.6). ### 2.2 Drug Product #### 2.2.1 Formulation Development A summary should be provided describing the development of the formulation, including identification of those attributes that are critical to the quality of the drug === PAGE 8 === Pharmaceutical Development product, taking into consideration intended usage and route of administration. Information from formal experimental designs can be useful in identifying critical or interacting variables that might be important to ensure the quality of the drug product. The summary should highlight the evolution of the formulation design from initial concept up to the final design. This summary should also take into consideration the choice of drug product components (e.g., the properties of the drug substance, excipients, container closure system, any relevant dosing device), the manufacturing process, and, if appropriate, knowledge gained from the development of similar drug product(s). Any excipient ranges included in the batch formula (3.2.P.3.2) should be justified in this section of the application; this justification can often be based on the experience gained during development or manufacture. A summary of formulations used in clinical safety and efficacy and in any relevant bioavailability or bioequivalence studies should be provided. Any changes between the proposed commercial formulation and those formulations used in pivotal clinical batches and primary stability batches should be clearly described and the rationale for the changes provided. Information from comparative in vitro studies (e.g., dissolution) or comparative in vivo studies (e.g., bioequivalence) that links clinical formulations to the proposed commercial formulation described in 3.2.P.1 should be summarized and a cross- reference to the studies (with study numbers) should be provided. Where attempts have been made to establish an in vitro/in vivo correlation, the results of those studies, and a cross-reference to the studies (with study numbers), should be provided in this section. A successful correlation can assist in the selection of appropriate dissolution acceptance criteria, and can potentially reduce the need for further bioequivalence studies following changes to the product or its manufacturing process. Any special design features of the drug product (e.g., tablet score line, overfill, anti- counterfeiting measure as it affects the drug product) should be identified and a rationale provided for their use. #### 2.2.2 Overages In general, use of an overage of a drug substance to compensate for degradation during manufacture or a product’s shelf life, or to extend shelf life, is discouraged. Any overages in the manufacture of the drug product, whether they appear in the final formulated product or not, should be justified considering the safety and efficacy of the product. Information should be provided on the 1) amount of overage, 2) reason for the overage (e.g., to compensate for expected and documented manufacturing losses), and 3) justification for the amount of overage. The overage should be included in the amount of drug substance listed in the batch formula (3.2.P.3.2). #### 2.2.3 Physicochemical and Biological Properties The physicochemical and biological properties relevant to the safety, performance or manufacturability of the drug product should be identified and discussed. This includes the physiological implications of drug substance and formulation attributes. Studies could include, for example, the development of a test for respirable fraction of an inhaled product. Similarly, information supporting the selection of dissolution vs. === PAGE 9 === Pharmaceutical Development disintegration testing, or other means to assure drug release, and the development and suitability of the chosen test, could be provided in this section. See also ICH Q6A Specifications: Test Procedures And Acceptance Criteria For New Drug Substances And New Drug Products: Chemical Substances; Decision Tree #4 (Part 3) and Decision Tree #7 (Part 1) or ICH Q6B Specifications: Test Procedures and Acceptance Criteria for Biotechnology/Biological Products. The discussion should cross-reference any relevant stability data in 3.2.P.8.3. ### 2.3 Manufacturing Process Development The selection, the control, and any improvement of the manufacturing process described in 3.2.P.3.3 (i.e., intended for commercial production batches) should be explained. It is important to consider the critical formulation attributes, together with the available manufacturing process options, in order to address the selection of the manufacturing process and confirm the appropriateness of the components. Appropriateness of the equipment used for the intended products should be discussed. Process development studies should provide the basis for process improvement, process validation, continuous process verification* (where applicable), and any process control requirements. Where appropriate, such studies should address microbiological as well as physical and chemical attributes. The knowledge gained from process development studies can be used, as appropriate, to justify the drug product specification (3.2.P.5.6). The manufacturing process development programme or process improvement programme should identify any critical process parameters that should be monitored or controlled (e.g., granulation end point) to ensure that the product is of the desired quality. For those products intended to be sterile an appropriate method of sterilization for the drug product and primary packaging material should be chosen and the choice justified. Significant differences between the manufacturing processes used to produce batches for pivotal clinical trials (safety, efficacy, bioavailability, bioequivalence) or primary stability studies and the process described in 3.2.P.3.3 should be discussed. The discussion should summarise the influence of the differences on the performance, manufacturability and quality of the product. The information should be presented in a way that facilitates comparison of the processes and the corresponding batch analyses information (3.2.P.5.4). The information should include, for example, (1) the identity (e.g., batch number) and use of the batches produced (e.g., bioequivalence study batch number), (2) the manufacturing site, (3) the batch size, and (4) any significant equipment differences (e.g., different design, operating principle, size). In order to provide flexibility for future process improvement, when describing the development of the manufacturing process, it is useful to describe measurement systems that allow monitoring of critical attributes or process end-points. Collection of process monitoring data during the development of the manufacturing process can provide useful information to enhance process understanding. The process control strategies that provide process adjustment capabilities to ensure control of all critical attributes should be described. * See Glossary for definition === PAGE 10 === Pharmaceutical Development An assessment of the ability of the process to reliably produce a product of the intended quality (e.g., the performance of the manufacturing process under different operating conditions, at different scales, or with different equipment) can be provided. An understanding of process robustness* can be useful in risk assessment and risk reduction (see ICH Q9 Quality Risk Management glossary for definition) and to support future manufacturing and process improvement, especially in conjunction with the use of risk management tools (see ICH Q9 Quality Risk Management). ### 2.4 Container Closure System The choice and rationale for selection of the container closure system for the commercial product (described in 3.2.P.7) should be discussed. Consideration should be given to the intended use of the drug product and the suitability of the container closure system for storage and transportation (shipping), including the storage and shipping container for bulk drug product, where appropriate. The choice of materials for primary packaging should be justified. The discussion should describe studies performed to demonstrate the integrity of the container and closure. A possible interaction between product and container or label should be considered. The choice of primary packaging materials should consider, e.g., choice of materials, protection from moisture and light, compatibility of the materials of construction with the dosage form (including sorption to container and leaching), and safety of materials of construction. Justification for secondary packaging materials should be included, when relevant. If a dosing device is used (e.g., dropper pipette, pen injection device, dry powder inhaler), it is important to demonstrate that a reproducible and accurate dose of the product is delivered under testing conditions which, as far as possible, simulate the use of the product. ### 2.5 Microbiological Attributes Where appropriate, the microbiological attributes of the drug product should be discussed in this section (3.2.P.2.5). The discussion should include, for example: • The rationale for performing or not performing microbial limits testing for non sterile drug products (e.g., Decision Tree #8 in ICH Q6A Specifications: Test Procedures and Acceptance Criteria for New Drug Substances and New Drug Products: Chemical Substances and ICH Q6B Specifications: Test Procedures and Acceptance Criteria for Biotechnology/Biological Products); • The selection and effectiveness of preservative systems in products containing antimicrobial preservative or the antimicrobial effectiveness of products that are inherently antimicrobial; • For sterile products, the integrity of the container closure system as it relates to preventing microbial contamination. Although chemical testing for preservative content is the attribute normally included in the drug product specification, antimicrobial preservative effectiveness should be demonstrated during development. The lowest specified concentration of antimicrobial preservative should be demonstrated to be effective in controlling micro- * See Glossary for definition === PAGE 11 === Pharmaceutical Development organisms by using an antimicrobial preservative effectiveness test. The concentration used should be justified in terms of efficacy and safety, such that the minimum concentration of preservative that gives the required level of efficacy throughout the intended shelf life of the product is used. Where relevant, microbial challenge testing under testing conditions that, as far as possible, simulate patient use should be performed during development and documented in this section. ### 2.6 Compatibility The compatibility of the drug product with reconstitution diluents (e.g., precipitation, stability) should be addressed to provide appropriate and supportive information for the labelling. This information should cover the recommended in-use shelf life, at the recommended storage temperature and at the likely extremes of concentration. Similarly, admixture or dilution of products prior to administration (e.g., product added to large volume infusion containers) might need to be addressed. 3. GLOSSARY Continuous Process Verification: An alternative approach to process validation in which manufacturing process performance is continuously monitored and evaluated. Design Space: The multidimensional combination and interaction of input variables (e.g., material attributes) and process parameters that have been demonstrated to provide assurance of quality. Working within the design space is not considered as a change. Movement out of the design space is considered to be a change and would normally initiate a regulatory post approval change process. Design space is proposed by the applicant and is subject to regulatory assessment and approval. Formal Experimental Design: A structured, organized method for determining the relationship between factors affecting a process and the output of that process. Also known as “Design of Experiments”. Lifecycle: All phases in the life of a product from the initial development through marketing until the product’s discontinuation. Process Analytical Technology (PAT): A system for designing, analyzing, and controlling manufacturing through timely measurements (i.e., during processing) of critical quality and performance attributes of raw and in-process materials and processes with the goal of ensuring final product quality. Process Robustness: Ability of a process to tolerate variability of materials and changes of the process and equipment without negative impact on quality. === PAGE 12 === Pharmaceutical Development Quality: The suitability of either a drug substance or drug product for its intended use. This term includes such attributes as the identity, strength, and purity (from ICH Q6A Specifications: Test Procedures and Acceptance Criteria for New Drug Substances and New Drug Products: Chemical Substances). === PAGE 13 === PART II: PHARMACEUTICAL DEVELOPMENT - ANNEX ICH Harmonised Tripartite Guideline Having reached Step 4 of the ICH Process at the ICH Steering Committee meeting on 13 November 2008, this guideline is recommended for adoption to the three regulatory parties to ICH 1. INTRODUCTION This guideline is an annex to ICH Q8 Pharmaceutical Development and provides further clarification of key concepts outlined in the core guideline. In addition, this annex describes the principles of quality by design1 (QbD). The annex is not intended to establish new standards or to introduce new regulatory requirements; however, it shows how concepts and tools (e.g., design space1) outlined in the parent Q8 document could be put into practice by the applicant for all dosage forms. Where a company chooses to apply quality by design and quality risk management (ICH Q9, Quality Risk Management), linked to an appropriate pharmaceutical quality system, opportunities arise to enhance science- and risk-based regulatory approaches (see ICH Q10, Pharmaceutical Quality System). Approaches to Pharmaceutical Development In all cases, the product should be designed to meet patients’ needs and the intended product performance. Strategies for product development vary from company to company and from product to product. The approach to, and extent of, development can also vary and should be outlined in the submission. An applicant might choose either an empirical approach or a more systematic approach to product development, or a combination of both. An illustration of the potential contrasts of these approaches is shown in Appendix 1. A more systematic approach to development (also defined as quality by design) can include, for example, incorporation of prior knowledge, results of studies using design of experiments, use of quality risk management, and use of knowledge management (see ICH Q10) throughout the lifecycle1 of the product. Such a systematic approach can enhance achieving the desired quality of the product and help the regulators to better understand a company’s strategy. Product and process understanding can be updated with the knowledge gained over the product lifecycle. A greater understanding of the product and its manufacturing process can create a basis for more flexible regulatory approaches. The degree of regulatory flexibility is predicated on the level of relevant scientific knowledge provided in the registration application. It is the knowledge gained and submitted to the authorities, and not the volume of data collected, that forms the basis for science- and risk-based submissions and regulatory evaluations. Nevertheless, appropriate data demonstrating that this knowledge is based on sound scientific principles should be presented with each application. Pharmaceutical development should include, at a minimum, the following elements: 1 See glossary === PAGE 14 === Pharmaceutical Development • Defining the quality target product profile1 (QTPP) as it relates to quality, safety and efficacy, considering e.g., the route of administration, dosage form, bioavailability, strength, and stability; • Identifying potential critical quality attributes1 (CQAs) of the drug product, so that those product characteristics having an impact on product quality can be studied and controlled; • Determining the critical quality attributes of the drug substance, excipients etc., and selecting the type and amount of excipients to deliver drug product of the desired quality1; • Selecting an appropriate manufacturing process ; • Defining a control strategy1. An enhanced, quality by design approach to product development would additionally include the following elements: • A systematic evaluation, understanding and refining of the formulation and manufacturing process, including; o Identifying, through e.g., prior knowledge, experimentation, and risk assessment, the material attributes and process parameters that can have an effect on product CQAs; o Determining the functional relationships that link material attributes and process parameters to product CQAs; • Using the enhanced product and process understanding in combination with quality risk management to establish an appropriate control strategy which can, for example, include a proposal for a design space(s) and/or real-time release testing1. As a result, this more systematic approach could facilitate continual improvement and innovation throughout the product lifecycle (See ICH Q10). 2. ELEMENTS OF PHARMACEUTICAL DEVELOPMENT The section that follows elaborates on possible approaches to gaining a more systematic, enhanced understanding of the product and process under development. The examples given are purely illustrative and are not intended to create new regulatory requirements. ### 2.1 Quality Target Product Profile The quality target product profile forms the basis of design for the development of the product. Considerations for the quality target product profile could include: • Intended use in clinical setting, route of administration, dosage form, delivery systems; • Dosage strength(s); • Container closure system; 1 See glossary === PAGE 15 === Pharmaceutical Development • Therapeutic moiety release or delivery and attributes affecting pharmacokinetic characteristics (e.g., dissolution, aerodynamic performance) appropriate to the drug product dosage form being developed; • Drug product quality criteria (e.g., sterility, purity, stability and drug release) appropriate for the intended marketed product. ### 2.2 Critical Quality Attributes A CQA is a physical, chemical, biological, or microbiological property or characteristic that should be within an appropriate limit, range, or distribution to ensure the desired product quality. CQAs are generally associated with the drug substance, excipients, intermediates (in-process materials) and drug product. CQAs of solid oral dosage forms are typically those aspects affecting product purity, strength, drug release and stability. CQAs for other delivery systems can additionally include more product specific aspects, such as aerodynamic properties for inhaled products, sterility for parenterals, and adhesion properties for transdermal patches. For drug substances, raw materials and intermediates, the CQAs can additionally include those properties (e.g., particle size distribution, bulk density) that affect drug product CQAs. Potential drug product CQAs derived from the quality target product profile and/or prior knowledge are used to guide the product and process development. The list of potential CQAs can be modified when the formulation and manufacturing process are selected and as product knowledge and process understanding increase. Quality risk management can be used to prioritize the list of potential CQAs for subsequent evaluation. Relevant CQAs can be identified by an iterative process of quality risk management and experimentation that assesses the extent to which their variation can have an impact on the quality of the drug product. ### 2.3 Risk Assessment: Linking Material Attributes and Process Parameters to Drug Product CQAs Risk assessment is a valuable science-based process used in quality risk management (see ICH Q9) that can aid in identifying which material attributes and process parameters potentially have an effect on product CQAs. Risk assessment is typically performed early in the pharmaceutical development process and is repeated as more information becomes available and greater knowledge is obtained. Risk assessment tools can be used to identify and rank parameters (e.g., process, equipment, input materials) with potential to have an impact on product quality, based on prior knowledge and initial experimental data. For an illustrative example, see Appendix 2. The initial list of potential parameters can be quite extensive, but can be modified and prioritized by further studies (e.g., through a combination of design of experiments, mechanistic models). The list can be refined further through experimentation to determine the significance of individual variables and potential interactions. Once the significant parameters are identified, they can be further studied (e.g., through a combination of design of experiments, mathematical models, or studies that lead to mechanistic understanding) to achieve a higher level of process understanding. === PAGE 16 === Pharmaceutical Development ### 2.4 Design Space The relationship between the process inputs (material attributes and process parameters) and the critical quality attributes can be described in the design space (see examples in Appendix 2). #### 2.4.1 Selection of Variables The risk assessment and process development experiments described in Section 2.3 can lead to an understanding of the linkage and effect of process parameters and material attributes on product CQAs, and also help identify the variables and their ranges within which consistent quality can be achieved. These process parameters and material attributes can thus be selected for inclusion in the design space. A description should be provided in the application of the process parameters and material attributes considered for the design space, those that were included, and their effect on product quality. The rationale for inclusion in the design space should be presented. In some cases it is helpful to provide also the rationale as to why some parameters were excluded. Knowledge gained from studies should be described in the submission. Process parameters and material attributes that were not varied through development should be highlighted. #### 2.4.2 Describing a Design Space in a Submission A design space can be described in terms of ranges of material attributes and process parameters, or through more complex mathematical relationships. It is possible to describe a design space as a time dependent function (e.g., temperature and pressure cycle of a lyophilisation cycle), or as a combination of variables such as components of a multivariate model. Scaling factors can also be included if the design space is intended to span multiple operational scales. Analysis of historical data can contribute to the establishment of a design space. Regardless of how a design space is developed, it is expected that operation within the design space will result in a product meeting the defined quality. Examples of different potential approaches to presentation of a design space are presented in Appendix 2. 2.4.3 Unit Operation Design Space(s) The applicant can choose to establish independent design spaces for one or more unit operations, or to establish a single design space that spans multiple operations. While a separate design space for each unit operation is often simpler to develop, a design space that spans the entire process can provide more operational flexibility. For example, in the case of a drug product that undergoes degradation in solution before lyophilisation, the design space to control the extent of degradation (e.g., concentration, time, temperature) could be expressed for each unit operation or as a sum over all unit operations. #### 2.4.4 Relationship of Design Space to Scale and Equipment When describing a design space, the applicant should consider the type of operational flexibility desired. A design space can be developed at any scale. The applicant should justify the relevance of a design space developed at small or pilot scale to the proposed production scale manufacturing process and discuss the potential risks in the scale-up operation. === PAGE 17 === Pharmaceutical Development If the applicant proposes the design space to be applicable to multiple operational scales, the design space should be described in terms of relevant scale-independent parameters. For example, if a product was determined to be shear sensitive in a mixing operation, the design space could include shear rate, rather than agitation rate. Dimensionless numbers and/or models for scaling can be included as part of the design space description. #### 2.4.5 Design Space Versus Proven Acceptable Ranges A combination of proven acceptable ranges 1 does not constitute a design space. However, proven acceptable ranges based on univariate experimentation can provide useful knowledge about the process. #### 2.4.6 Design Space and Edge of Failure It can be helpful to determine the edge of failure for process parameters or material attributes, beyond which the relevant quality attributes cannot be met. However, determining the edge of failure or demonstrating failure modes are not essential parts of establishing a design space. ### 2.5 Control Strategy A control strategy is designed to ensure that a product of required quality will be produced consistently. The elements of the control strategy discussed in Section P.2 of the dossier should describe and justify how in-process controls and the controls of input materials (drug substance and excipients), intermediates (in-process materials), container closure system, and drug products contribute to the final product quality. These controls should be based on product, formulation and process understanding and should include, at a minimum, control of the critical process parameters1 and material attributes. A comprehensive pharmaceutical development approach will generate process and product understanding and identify sources of variability. Sources of variability that can impact product quality should be identified, appropriately understood, and subsequently controlled. Understanding sources of variability and their impact on downstream processes or processing, in-process materials, and drug product quality can provide an opportunity to shift controls upstream and minimise the need for end product testing. Product and process understanding, in combination with quality risk management (see ICH Q9), will support the control of the process such that the variability (e.g., of raw materials) can be compensated for in an adaptable manner to deliver consistent product quality. This process understanding can enable an alternative manufacturing paradigm where the variability of input materials could be less tightly constrained. Instead it can be possible to design an adaptive process step (a step that is responsive to the input materials) with appropriate process control to ensure consistent product quality. Enhanced understanding of product performance can justify the use of alternative approaches to determine that the material is meeting its quality attributes. The use of such alternatives could support real time release testing. For example, disintegration could serve as a surrogate for dissolution for fast-disintegrating solid forms with highly soluble drug substances. Unit dose uniformity performed in-process (e.g., using 1 See glossary === PAGE 18 === Pharmaceutical Development weight variation coupled with near infrared (NIR) assay) can enable real time release testing and provide an increased level of quality assurance compared to the traditional end-product testing using compendial content uniformity standards. Real time release testing can replace end product testing, but does not replace the review and quality control steps called for under GMP to release the batch. A control strategy can include, but is not limited to, the following: • Control of input material attributes (e.g., drug substance, excipients, primary packaging materials) based on an understanding of their impact on processability or product quality; • Product specification(s); • Controls for unit operations that have an impact on downstream processing or product quality (e.g., the impact of drying on degradation, particle size distribution of the granulate on dissolution); • In-process or real-time release testing in lieu of end-product testing (e.g. measurement and control of CQAs during processing); • A monitoring program (e.g., full product testing at regular intervals) for verifying multivariate prediction models. A control strategy can include different elements. For example, one element of the control strategy could rely on end-product testing, whereas another could depend on real-time release testing. The rationale for using these alternative approaches should be described in the submission. Adoption of the principles in this guideline can support the justification of alternative approaches to the setting of specification attributes and acceptance criteria as described in Q6A and Q6B. ### 2.6 Product Lifecycle Management and Continual Improvement Throughout the product lifecycle, companies have opportunities to evaluate innovative approaches to improve product quality (see ICH Q10). Process performance can be monitored to ensure that it is working as anticipated to deliver product quality attributes as predicted by the design space. This monitoring could include trend analysis of the manufacturing process as additional experience is gained during routine manufacture. For certain design spaces using mathematical models, periodic maintenance could be useful to ensure the model’s performance. The model maintenance is an example of activity that can be managed within a company‘s own internal quality system provided the design space is unchanged. Expansion, reduction or redefinition of the design space could be desired upon gaining additional process knowledge. Change of design space is subject to regional requirements. 3. SUBMISSION OF PHARMACEUTICAL DEVELOPMENT AND RELATED INFORMATION IN COMMON TECHNICAL DOCUMENTS (CTD) FORMAT Pharmaceutical development information is submitted in Section P.2 of the CTD. Other information resulting from pharmaceutical development studies could be accommodated by the CTD format in a number of different ways and some specific === PAGE 19 === Pharmaceutical Development suggestions are provided below. However, the applicant should clearly indicate where the different information is located. In addition to what is submitted in the application, certain aspects (e.g., product lifecycle management, continual improvement) of this guideline are handled under the applicant’s pharmaceutical quality system (see ICH Q10). ### 3.1 Quality Risk Management and Product and Process Development Quality risk management can be used at different stages during product and process development and manufacturing implementation. The assessments used to guide and justify development decisions can be included in the relevant sections of P.2. For example, risk analyses and functional relationships linking material attributes and process parameters to product CQAs can be included in P.2.1, P.2.2, and P.2.3. Risk analyses linking the design of the manufacturing process to product quality can be included in P.2.3. ### 3.2 Design Space As an element of the proposed manufacturing process, the design space(s) can be described in the section of the application that includes the description of the manufacturing process and process controls (P.3.3). If appropriate, additional information can be provided in the section of the application that addresses the controls of critical steps and intermediates (P.3.4). The product and manufacturing process development sections of the application (P.2.1, P.2.2, and P.2.3) are appropriate places to summarise and describe product and process development studies that provide the basis for the design space(s). The relationship of the design space(s) to the overall control strategy can be discussed in the section of the application that includes the justification of the drug product specification (P.5.6). ### 3.3 Control Strategy The section of the application that includes the justification of the drug product specification (P.5.6) is a good place to summarise the overall drug product control strategy. However, detailed information about input material controls and process controls should still be provided in the appropriate CTD format sections (e.g., drug substance section (S), control of excipients (P.4), description of manufacturing process and process controls (P.3.3), controls of critical steps and intermediates (P.3.4)). ### 3.4 Drug Substance Related Information If drug substance CQAs have the potential to affect the CQAs or manufacturing process of the drug product, some discussion of drug substance CQAs can be appropriate in the pharmaceutical development section of the application (e.g., P.2.1). === PAGE 20 === Pharmaceutical Development 4. GLOSSARY Control Strategy: A planned set of controls, derived from current product and process understanding that ensures process performance and product quality. The controls can include parameters and attributes related to drug substance and drug product materials and components, facility and equipment operating conditions, in-process controls, finished product specifications, and the associated methods and frequency of monitoring and control. (ICH Q10) Critical Process Parameter (CPP): A process parameter whose variability has an impact on a critical quality attribute and therefore should be monitored or controlled to ensure the process produces the desired quality. Critical Quality Attribute (CQA): A physical, chemical, biological or microbiological property or characteristic that should be within an appropriate limit, range, or distribution to ensure the desired product quality. Design Space: The multidimensional combination and interaction of input variables (e.g., material attributes) and process parameters that have been demonstrated to provide assurance of quality. Working within the design space is not considered as a change. Movement out of the design space is considered to be a change and would normally initiate a regulatory post approval change process. Design space is proposed by the applicant and is subject to regulatory assessment and approval (ICH Q8). Lifecycle: All phases in the life of a product from the initial development through marketing until the product’s discontinuation (ICH Q8). Proven Acceptable Range: A characterised range of a process parameter for which operation within this range, while keeping other parameters constant, will result in producing a material meeting relevant quality criteria. Quality: The suitability of either a drug substance or a drug product for its intended use. This term includes such attributes as the identity, strength, and purity (ICH Q6A). Quality by Design (QbD): A systematic approach to development that begins with predefined objectives and emphasizes product and process understanding and process control, based on sound science and quality risk management. Quality Target Product Profile (QTPP): A prospective summary of the quality characteristics of a drug product that ideally will be achieved to ensure the desired quality, taking into account safety and efficacy of the drug product. === PAGE 21 === Pharmaceutical Development Real Time Release Testing: The ability to evaluate and ensure the quality of in-process and/or final product based on process data, which typically include a valid combination of measured material attributes and process controls. === PAGE 22 === Pharmaceutical Development Appendix 1. Differing Approaches to Pharmaceutical Development The following table has been developed to illustrate some potential contrasts between what might be considered a minimal approach and an enhanced, quality by design approach regarding different aspects of pharmaceutical development and lifecycle management. The comparisons are shown merely to aid in the understanding of a range of potential approaches to pharmaceutical development and should not be considered to be all-encompassing. The table is not intended to specifically define the only approach a company could choose to follow. In the enhanced approach, establishing a design space or using real time release testing is not necesserily expected. Current practices in the pharmaceutical industry vary and typically lie between the two approaches presented in the table. Aspect Minimal Approaches Enhanced, Quality by Design Approaches Overall Pharmaceutical Development • Mainly empirical • Developmental research often conducted one variable at a time • Systematic, relating mechanistic understanding of material attributes and process parameters to drug product CQAs • Multivariate experiments to understand product and process • Establishment of design space • PAT tools utilised Manufacturing Process • Fixed • Validation primarily based on initial full-scale batches • Focus on optimisation and reproducibility • Adjustable within design space • Lifecycle approach to validation and, ideally, continuous process verification • Focus on control strategy and robustness • Use of statistical process control methods Process Controls • In-process tests primarily for go/no go decisions • Off-line analysis • PAT tools utilised with appropriate feed forward and feedback controls • Process operations tracked and trended to support continual improvement efforts post- approval Product Specifications • Primary means of control • Based on batch data available at time of registration • Part of the overall quality control strategy • Based on desired product performance with relevant supportive data Control Strategy • Drug product quality controlled primarily by intermediates (in- process materials) and end product testing • Drug product quality ensured by risk-based control strategy for well understood product and process • Quality controls shifted upstream, with the possibility of real-time release testing or reduced end-product testing Lifecycle Management • Reactive (i.e., problem solving and corrective action) • Preventive action • Continual improvement facilitated === PAGE 23 === Pharmaceutical Development Appendix 2. Illustrative Examples A. Use of a risk assessment tool. For example, a cross-functional team of experts could work together to develop an Ishikawa (fishbone) diagram that identifies potential variables which can have an impact on the desired quality attribute. The team could then rank the variables based on probability, severity, and detectability using failure mode effects analysis (FMEA) or similar tools based on prior knowledge and initial experimental data. Design of experiments or other experimental approaches could then be used to evaluate the impact of the higher ranked variables, to gain greater understanding of the process, and to develop a proper control strategy. Ishikawa Diagram Water Content Drying Granulation Raw Materials Compressing Plant Factors Temp/RH Precompressing Main Compressing Feeder Speed Press Speed Punch Penetration Depth Temp RH Air Flow Shock Cycle Drug Substance P.S. Process Conditions LOD Diluents P.S. LOD Other Lubricant Disintegrant Binder Water Binder Temp Spray Rate Spray Pattern P.S. Scrape Down Chopper Speed Mixer Speed Endpoint Power Time Age Tooling Operator Training Analytical Method Sampling Feed Frame Tablet Drying Granulation Raw Materials Compressing Plant Factors Temp/RH Precompressing Main Compressing Feeder Speed Press Speed Punch Penetration Depth Temp RH Air Flow Shock Cycle Drug Substance P.S. Process Conditions LOD Diluents P.S. LOD Other Lubricant Disintegrant Binder Water Binder Temp Spray Rate Spray Pattern P.S. Scrape Down Chopper Speed Mixer Speed Endpoint Power Time Age Tooling Operator Training Analytical Method Sampling Feed Frame === PAGE 24 === Pharmaceutical Development B. Depiction of interactions The figure below depicts the presence or absence of interactions among three process parameters on the level of degradation product Y. The figure shows a series of two- dimensional plots showing the effect of interactions among three process parameters (initial moisture content, temperature, mean particle size) of the drying operation of a granulate (drug product intermediate) on degradation product Y. The relative slopes of the lines or curves within a plot indicate if interaction is present. In this example, initial moisture content and temperature are interacting; but initial moisture content and mean particle size are not, nor are temperature and mean particle size. 0.5 1.0 1.5 %Y Initial moisture content (IMC) 100°C 15% 30% Temperature 700 µm Mean particle size (d50) 1 2 3 4 5 6 7 100 µm 60°C 700 µm 100 µm 15% 30% 100°C 60°C (d50 = 400 µm) (Temp = 80°C) (Temp = 80°C) (IMC = 22.5%) (IMC = 22.5%) Initial Moisture Content (%) Temp (°C) Mean Particle Size (x100 µm) 0.5 1.0 1.5 %Y 0.5 1.0 1.5 %Y (d50 = 400 µm) 0.5 1.0 1.5 %Y Initial moisture content (IMC) 100°C 15% 30% Temperature 700 µm Mean particle size (d50) 1 2 3 4 5 6 7 100 µm 60°C 700 µm 100 µm 15% 30% 100°C 60°C (d50 = 400 µm) (Temp = 80°C) (Temp = 80°C) (IMC = 22.5%) (IMC = 22.5%) Initial Moisture Content (%) Temp (°C) Mean Particle Size (x100 µm) 0.5 1.0 1.5 %Y 0.5 1.0 1.5 %Y (d50 = 400 µm) === PAGE 25 === Pharmaceutical Development C. Presentations of design space Example 1: Response graphs for dissolution are depicted as a surface plot (Figure 1a) and a contour plot (Figure 1b). Parameters 1 and 2 are factors of a granulation operation that affect the dissolution rate of a tablet (e.g., excipient attribute, water amount, granule size.) *[Figure 1a: Response surface plot of]* dissolution as a function of two parameters of a granulation operation. Dissolution above 80% is desired. *[Figure 1b: Contour plot of dissolution]* from example 1a. *[Figure 1c: Design space for granulation]* parameters, defined by a non-linear combination of their ranges, that delivers satisfactory dissolution (i.e., >80%). *[Figure 1d: Design space for granulation]* parameters, defined by a linear combination of their ranges, that delivers satisfactory dissolution (i.e., >80%). Two examples are given of potential design spaces. In Figure 1c, the design space is defined by a non-linear combination of parameter ranges that delivers the dissolution critical quality attribute. In this example, the design space is expressed by the response surface equation resolved at the limit for satisfactory response (i.e.,80% dissolution). The acceptable range of one parameter is dependent on the value of the other. For example: - If Parameter 1 has a value of 46, then Parameter 2 has a range of 0 and 1.5 - If Parameter 2 has a value of 0.8, then Parameter 1 has a range of 43 and 54 === PAGE 26 === Pharmaceutical Development The approach in Figure 1c allows the maximum range of operation to achieve the desired dissolution rate. In Figure 1d, the design space is defined as a smaller range, based on a linear combination of parameters. - Parameter 1 has a range of 44 and 53 - Parameter 2 has a range of 0 and 1.1 While the approach in Figure 1d is more limiting, the applicant may prefer it for operational simplicity. This example discusses only two parameters and thus can readily be presented graphically. When multiple parameters are involved, the design space can be presented for two parameters, in a manner similar to the examples shown above, at different values (e.g., high, middle, low) within the range of the third parameter, the fourth parameter, and so on. Alternatively, the design space can be explained mathematically through equations describing relationships between parameters for successful operation. === PAGE 27 === Pharmaceutical Development Example 2: Design space determined from the common region of successful operating ranges for multiple CQAs. The relations of two CQAs, i.e., tablet friability and dissolution, to two process parameters of a granulation operation are shown in Figures 2a and 2b. Parameters 1 and 2 are factors of a granulation operation that affect the dissolution rate of a tablet (e.g., excipient attribute, water amount, granule size). Figure 2c shows the overlap of these regions and the maximum ranges of the proposed design space. The applicant can elect to use the entire region as the design space, or some subset thereof. > 80% 75-80% 70-75% 65-70% 60-65% > 80% 75-80% 70-75% 65-70% 60-65% 4-5% 3-4% 2-3% < 2% 4-5% 3-4% 2-3% < 2% *[Figure 2a: Contour plot of dissolution as]* a function of Parameters 1 and 2. *[Figure 2b: Contour plot of friability as a]* function of Parameters 1 and 2. *[Figure 2c: Proposed design space,]* comprised of the overlap region of ranges for friability and or dissolution. === PAGE 28 === Pharmaceutical Development Example 3: The design space for a drying operation that is dependent upon the path of temperature and/or pressure over time. The end point for moisture content is 1-2%. Operating above the upper limit of the design space can cause excessive impurity formation, while operating below the lower limit of the design space can result in excessive particle attrition. 0% 5% 10% 15% 20% 25% 30% 35% time (hr) Moisture Content Design space lower limit Design space upper limit Excessive impurity formation Excessive particle attrition Endpoint criterion { --- ### Document: ICH Q9R1 Complete (ICH) # ICH Q9(R1) Quality Risk Management: Quality Risk Management Guideline === PAGE 1 === INTERNATIONAL COUNCIL FOR HARMONISATION OF TECHNICAL REQUIREMENTS FOR PHARMACEUTICALS FOR HUMAN USE ICH HARMONISED GUIDELINE QUALITY RISK MANAGEMENT Q9(R1) Final version Adopted on 18 January 2023 This Guideline has been developed by the appropriate ICH Expert Working Group and has been subject to consultation by the regulatory parties, in accordance with the ICH Process. At Step 4 of the Process the final draft is recommended for adoption to the regulatory bodies of ICH regions. === PAGE 2 === Q9(R1) Document History Q9 Code History Date Q9 Approval by the Steering Committee under Step 4 and recommendation for adoption to the three ICH regulatory bodies. 9 November 2005 Revision of Q9 Code History Date Q9(R1) Endorsement by the Members of the ICH Assembly under Step 2 and release for public consultation (document dated 18 November 2021). 18 November 2021 Q9(R1) Adoption by the Regulatory Members of the ICH Assembly under Step 4. 18 January 2023 Legal notice: This document is protected by copyright and may, with the exception of the ICH logo, be used, reproduced, incorporated into other works, adapted, modified, translated or distributed under a public license provided that ICH's copyright in the document is acknowledged at all times. In case of any adaption, modification or translation of the document, reasonable steps must be taken to clearly label, demarcate or otherwise identify that changes were made to or based on the original document. Any impression that the adaption, modification or translation of the original document is endorsed or sponsored by the ICH must be avoided. The document is provided "as is" without warranty of any kind. In no event shall the ICH or the authors of the original document be liable for any claim, damages or other liability arising from the use of the document. The above-mentioned permissions do not apply to content supplied by third parties. Therefore, for documents where the copyright vests in a third party, permission for reproduction must be obtained from this copyright holder. === PAGE 3 === i ICH HARMONISED GUIDELINE QUALITY RISK MANAGEMENT Q9(R1) ICH Consensus Guideline TABLE OF CONTENTS 1. INTRODUCTION .................................................................................................................. 1 2. SCOPE .................................................................................................................................... 2 3. PRINCIPLES OF QUALITY RISK MANAGEMENT ...................................................... 2 4. GENERAL QUALITY RISK MANAGEMENT PROCESS ............................................. 3 4.1. Responsibilities ........................................................................................................................ 3 4.2. Initiating a Quality Risk Management Process ........................................................................ 4 4.3. Risk Assessment ....................................................................................................................... 4 4.4. Risk Control ............................................................................................................................. 5 4.5. Risk Communication ............................................................................................................... 5 4.6. Risk Review ............................................................................................................................. 6 5. RISK MANAGEMENT METHODOLOGY ....................................................................... 6 5.1 Formality in Quality Risk Management ................................................................................... 7 5.2 Risk-Based Decision-Making .................................................................................................. 8 5.3 Managing and Minimizing Subjectivity .................................................................................. 9 6. INTEGRATION OF QUALITY RISK MANAGEMENT INTO INDUSTRY AND REGULATORY OPERATIONS ..................................................................................................... 9 ### 6.1 The role of Quality Risk Management in Addressing Product Availability Risks Arising from Quality/Manufacturing Issues ........................................................................................................... 10 7. DEFINITIONS ...................................................................................................................... 11 8. REFERENCES ..................................................................................................................... 13 ANNEX I: QUALITY RISK MANAGEMENT METHODS AND TOOLS .............................. 15 I.1 Basic Risk Management Facilitation Methods...................................................................... 15 I.2 Failure Mode Effects Analysis (FMEA) ............................................................................... 15 I.3 Failure Mode, Effects and Criticality Analysis (FMECA) .................................................... 15 I.4 Fault Tree Analysis (FTA) ..................................................................................................... 16 I.5 Hazard Analysis and Critical Control Points (HACCP) ....................................................... 16 I.6 Hazard Operability Analysis (HAZOP) ................................................................................ 17 === PAGE 4 === ICH Q9(R1) Guideline I.7 Preliminary Hazard Analysis (PHA) ..................................................................................... 17 I.8 Risk Ranking and Filtering ................................................................................................... 17 I.9 Supporting Statistical Tools .................................................................................................. 18 ANNEX II: POTENTIAL APPLICATIONS FOR QUALITY RISK MANAGEMENT ......... 19 II.1 Quality Risk Management as Part of Integrated Quality Management ................................ 19 II.2 Quality Risk Management as Part of Regulatory Operations ............................................... 20 II.3 Quality Risk Management as Part of Development .............................................................. 20 II.4 Quality Risk Management for Facilities, Equipment and Utilities ....................................... 21 II.5 Quality Risk Management as Part of Materials Management............................................... 22 II.6 Quality Risk Management as Part of Production .................................................................. 23 II.7 Quality Risk Management as Part of Laboratory Control and Stability Studies................... 23 II.8 Quality Risk Management as Part of Packaging and Labeling ............................................. 24 II.9 Quality Risk Management as Part of Supply Chain Control ................................................ 24 === PAGE 5 === ICH Q9(R1) Guideline 1. INTRODUCTION Risk management principles are effectively utilized in many areas of business and government including finance, insurance, occupational safety, public health, pharmacovigilance, and by agencies regulating these industries. In the pharmaceutical sector, the principles and framework of ICH Q9, coupled with the official ICH training material that supports this guideline, are instrumental in enhancing the application of effective quality risk management by industry and regulators. The importance of quality systems has been recognized in the pharmaceutical industry and it is evident that quality risk management is a valuable component of an effective quality system. It is commonly understood that risk is defined as the combination of the probability of occurrence of harm and the severity of that harm. However, achieving a shared understanding of the application of risk management among diverse stakeholders is difficult because each stakeholder might perceive different potential harms, place a different probability on each harm occurring and attribute different severities to each harm. In addition, subjectivity can directly impact the effectiveness of risk management activities and the decisions made. Therefore, it is important that subjectivity is managed and minimized. In relation to pharmaceuticals, although there are a variety of stakeholders, including patients and medical practitioners as well as government and industry, the protection of the patient is of prime importance when managing the risk to product quality and availability, when availability risks arise from quality/manufacturing issues. The manufacturing and use of a drug (medicinal) product, including its components, necessarily entail some degree of risk. The risk to its quality is just one component of the overall risk. It is important to understand that product quality is assured based on appropriate risk- based decision-making throughout the product lifecycle, such that the attributes that are important to the quality of the drug (medicinal) product are maintained and the product remains safe and effective. An effective quality risk management approach can further ensure the quality of the drug (medicinal) product to the patient by providing a proactive means to identify and control potential quality issues during development, manufacturing, and distribution. This includes an appropriate application of root cause analysis that can identify and address the root cause(s) and other causal factors (e.g., human-related) of such issues. A proactive approach to quality risk management is beneficial, as it facilitates robust product design and continual improvement, and it is of strategic importance in achieving an effective pharmaceutical quality system. (See ICH Q10 for guidance in relation to an effective pharmaceutical quality system.) Additionally, use of quality risk management can improve the decision-making if a quality problem arises. In the development phase and as part of validation, quality risk management is part of building knowledge and understanding risk scenarios, so that appropriate risk control can be decided upon for use during the commercial manufacturing phase. In this context, knowledge is used to make informed risk-based decisions, trigger re-evaluations and stimulate continual improvements. Effective and proactive quality risk management can enable better, more informed and timely decisions throughout the lifecycle. This can provide regulators with greater assurance of a company’s ability to deal with potential risks and avert problems, and can beneficially affect the extent and level of direct regulatory oversight. === PAGE 6 === ICH Q9(R1) Guideline The application of digitalization and emerging technologies in the manufacture and control of drug (medicinal) products can lead to risk reduction, when such technologies are fit for their intended use. However, they can also introduce other risks that may need to be controlled. The application of quality risk management to the design, validation and technology transfer of advanced production processes and analytical methods, advanced data analysis methods and computerized systems is important. The purpose of this document is to offer a systematic approach to quality risk management that leads to better, more informed, and timely decisions. It serves as a foundation or resource document that is independent of, yet supports, other ICH Quality documents and complements existing quality practices, requirements, standards, and guidelines within the pharmaceutical industry and regulatory environment. It specifically provides guidance on the principles and some of the tools of quality risk management that can enable more effective and consistent risk-based decisions, both by regulators and industry, regarding the quality of drug substances and drug (medicinal) products across the product lifecycle. It is not intended to create any new expectations beyond the current regulatory requirements. An understanding of formality in quality risk management may lead to resources being used more efficiently, where lower risk issues are dealt with via less formal means, freeing up resources for managing higher risk issues and more complex problems that may require increased levels of rigor and effort. An understanding of formality can also support risk-based decision-making, where the level of formality that is applied may reflect the degree of importance of the decision, as well as the level of uncertainty and complexity which may be present. Appropriate use of quality risk management can facilitate but does not obviate industry’s obligation to comply with regulatory requirements and does not replace appropriate communications between industry and regulators. Quality risk management should not be used in a manner where decisions are made that justify a practice that would otherwise, in accordance with regulations and/or guidance, be deemed unacceptable. 2. SCOPE This guideline provides principles and examples of tools for quality risk management that can be applied to different aspects of pharmaceutical quality. These aspects include development, manufacturing, distribution, and the inspection and submission/review processes throughout the lifecycle of drug substances, drug (medicinal) products, biological and biotechnological products (including the use of raw materials, solvents, excipients, packaging and labeling materials in drug (medicinal) products, biological and biotechnological products). 3. PRINCIPLES OF QUALITY RISK MANAGEMENT Two primary principles of quality risk management are: • The evaluation of the risk to quality should be based on scientific knowledge and ultimately link to the protection of the patient. (Note: Risk to quality includes situations where product availability may be impacted, leading to potential patient harm.) • The level of effort, formality and documentation of the quality risk management process should be commensurate with the level of risk. === PAGE 7 === ICH Q9(R1) Guideline 4. GENERAL QUALITY RISK MANAGEMENT PROCESS Quality risk management is a systematic process for the assessment, control, communication and review of risks to the quality of the drug (medicinal) product across the product lifecycle. A model for quality risk management is outlined in the diagram (Figure 1). Other models could be used. The emphasis on each component of the framework might differ from case to case but a robust process will incorporate consideration of all the elements at a level of detail that is commensurate with the specific risk. *[Figure 1: Overview of a typical quality risk management process]* Decision nodes are not shown in the diagram above because decisions can occur at any point in the process. These decisions might be to return to the previous step and seek further information, to adjust the risk models or even to terminate the risk management process based upon information that supports such a decision. Note: “unacceptable” in the flowchart does not only refer to statutory, legislative or regulatory requirements, but also to the need to revisit the risk assessment process. 4.1. Responsibilities Quality risk management activities are usually, but not always, undertaken by interdisciplinary teams. When teams are formed, they should include experts from the appropriate areas (e.g., quality unit, product development, business development, engineering, regulatory affairs, production operations, sales and marketing, supply chain, legal, statistics and clinical) in addition to individuals who are knowledgeable about the quality risk management process. Risk Assessment Initiate Quality Risk Management Process Hazard Identification Risk Analysis Risk Evaluation Risk Management tools Risk Communication Risk Control Risk Reduction Output / Result of the Quality Risk Management Process Risk Review Risk Acceptance unacceptable Review Events === PAGE 8 === ICH Q9(R1) Guideline Decision makers should • take responsibility for coordinating quality risk management across various functions and departments of their organization; • assure that a quality risk management process is defined, deployed and reviewed and that adequate resources and knowledge are available; and • assure that subjectivity in quality risk management activities is managed and minimized, to facilitate scientifically robust risk-based decision-making. 4.2. Initiating a Quality Risk Management Process Quality risk management should include systematic processes designed to coordinate, facilitate and improve science-based decision-making with respect to risk. Possible steps used to initiate and plan a quality risk management process might include the following: • Define the problem and/or risk question, including pertinent assumptions identifying the potential for risk; • Assemble background information and/ or data on the potential hazard, harm or human health impact relevant to the risk assessment; • Identify a leader and necessary resources; • Specify a timeline, deliverables and appropriate level of decision-making for the risk management process. 4.3. Risk Assessment Risk assessment consists of the identification of hazards and the analysis and evaluation of risks associated with exposure to those hazards (as defined below). Quality risk assessments begin with a well-defined problem description or risk question. When the risk in question is well defined, an appropriate risk management tool (see examples in section 5) and the types of information needed to address the risk question will be more readily identifiable. As an aid to clearly defining the risk(s) for risk assessment purposes, three fundamental questions are often helpful: 1. What might go wrong? 2. What is the likelihood (probability) it will go wrong? 3. What are the consequences (severity)? Hazard identification is a systematic use of information to identify hazards referring to the risk question or problem description. Information can include historical data, theoretical analysis, informed opinions, and the concerns of stakeholders. Hazard identification addresses the “What might go wrong?” question, including identifying the possible consequences. This provides the basis for further steps in the quality risk management process. Risk analysis is the estimation of the risk associated with the identified hazards. It is the qualitative or quantitative process of linking the likelihood of occurrence and severity of harms. In some risk management tools, the ability to detect the harm (detectability) also factors in the estimation of risk. Risk evaluation compares the identified and analyzed risk against given risk criteria. Risk evaluations consider the strength of evidence for all three of the fundamental questions. In doing an effective risk assessment, the robustness of the data set is important because it === PAGE 9 === ICH Q9(R1) Guideline determines the quality of the output. Revealing assumptions and reasonable sources of uncertainty will enhance confidence in this output and/or help identify its limitations. Uncertainty is due to a combination of incomplete knowledge about a process and its expected or unexpected variability. Typical sources of uncertainty include gaps in knowledge, gaps in pharmaceutical science and process understanding, sources of harm (e.g., failure modes of a process, sources of variability), and probability of detection of problems. The output of a risk assessment is either a quantitative estimate of risk or a qualitative description of a range of risk. When risk is expressed quantitatively, a numerical probability is used. Alternatively, risk can be expressed using qualitative descriptors, such as “high”, “medium”, or “low”, which should be defined in as much detail as possible. Sometimes a "risk score" is used to further define descriptors in risk ranking. In quantitative risk assessments, a risk estimate provides the likelihood of a specific consequence, given a set of risk-generating circumstances. Thus, quantitative risk estimation is useful for one particular consequence at a time. Alternatively, some risk management tools use a relative risk measure to combine multiple levels of severity and probability into an overall estimate of relative risk. The intermediate steps within a scoring process can sometimes employ quantitative risk estimation. 4.4. Risk Control Risk control includes decision-making to reduce and/or accept risks. The purpose of risk control is to reduce the risk to an acceptable level. The amount of effort used for risk control should be proportional to the significance of the risk. Decision makers might use different processes, including benefit-cost analysis, for understanding the optimal level of risk control. Risk control might focus on the following questions: 1. Is the risk above an acceptable level? 2. What can be done to reduce or eliminate risks? 3. What is the appropriate balance among benefits, risks and resources? 4. Are new risks introduced as a result of the identified risks being controlled? Risk reduction focuses on processes for mitigation or avoidance of quality risk when it exceeds a specified (acceptable) level (see Fig. 1). Risk reduction might include actions taken to mitigate the severity and probability of harm. Processes that improve the detectability of hazards and quality risks might also be used as part of a risk control strategy. The implementation of risk reduction measures can introduce new risks into the system or increase the significance of other existing risks. Hence, it might be appropriate to revisit the risk assessment to identify and evaluate any possible change in risk after implementing a risk reduction process. Risk acceptance is a decision to accept risk. For some types of harms, even the best quality risk management practices might not entirely eliminate risk. In these circumstances, it might be agreed that an appropriate quality risk management strategy has been applied and that quality risk is reduced to a specified (acceptable) level. This (specified) acceptable level will depend on many parameters and should be decided on a case-by-case basis. 4.5. Risk Communication Risk communication is the sharing of information about risk and risk management between === PAGE 10 === ICH Q9(R1) Guideline the decision makers and others. Parties can communicate at any stage of the risk management process (see Fig. 1: dashed arrows). The output/result of the quality risk management process should be appropriately communicated and documented (see Fig. 1: solid arrows). Communications might include those among interested parties; e.g., regulators and industry, industry and the patient, within a company, industry or regulatory authority, etc. The included information might relate to the existence, nature, form, probability, severity, acceptability, control, treatment, detectability or other aspects of risks to quality. Communication need not be carried out for each and every risk acceptance. Between the industry and regulatory authorities, communication concerning quality risk management decisions might be conducted through existing channels as specified in regulations and guidances. 4.6. Risk Review Risk management should be an ongoing part of the quality management process. A mechanism to review or monitor events should be implemented. The output/results of the risk management process should be reviewed to take into account new knowledge and experience. Once a quality risk management process has been initiated, that process should continue to be utilized for events that might impact the original quality risk management decision, whether these events are planned (e.g., results of product review, inspections, audits, change control) or unplanned (e.g., root cause from failure investigations, recall). The frequency of any review should be based upon the level of risk. Risk review might include reconsideration of risk acceptance decisions (section 4.4). 5. RISK MANAGEMENT METHODOLOGY Quality risk management supports a scientific and practical approach to decision-making. It provides documented, transparent and reproducible methods to accomplish steps of the quality risk management process based on current knowledge about assessing the probability, severity and sometimes detectability of the hazards, and their associated risks. While detectability may not be a discrete factor in some quality risk management methods, detection controls are important as they can reduce the probability of occurrence of harm. Traditionally, risks to quality have been assessed and managed in a variety of ways (empirical and/or internal procedures) based on, for example, compilation of observations, trends and other information. Such approaches continue to provide useful information that might support topics such as handling of complaints, quality defects, deviations and allocation of resources. Additionally, the pharmaceutical industry and regulators can assess and manage risk using recognized risk management tools and/ or internal procedures (e.g., standard operating procedures). Below is a non-exhaustive list of some of these tools (further details in Annex 1 and section 8): • Basic risk management facilitation methods (flowcharts, check sheets etc.); • Failure Mode Effects Analysis (FMEA); • Failure Mode, Effects and Criticality Analysis (FMECA); • Fault Tree Analysis (FTA); • Hazard Analysis and Critical Control Points (HACCP); • Hazard Operability Analysis (HAZOP); • Preliminary Hazard Analysis (PHA); === PAGE 11 === ICH Q9(R1) Guideline • Risk ranking and filtering; • Supporting statistical tools. It might be appropriate to adapt these tools for use in specific areas pertaining to drug substance and drug (medicinal) product quality. Quality risk management methods and the supporting statistical tools can be used in combination (e.g., Probabilistic Risk Assessment). Combined use provides flexibility that can facilitate the application of quality risk management principles. The degree of rigor and formality of quality risk management should reflect available knowledge and be commensurate with the level of uncertainty, importance and complexity of the issue to be addressed. ### 5.1 Formality in Quality Risk Management Formality in quality risk management is not a binary concept (i.e. formal/informal); varying degrees of formality may be applied during quality risk management activities, including when making risk-based decisions. In this way, formality can be considered a continuum (or spectrum), ranging from low to high. When determining how much formality to apply to a given quality risk management activity, certain factors may be considered. These may include, for example, the following: • Uncertainty: The term “uncertainty” in quality risk management means lack of knowledge about hazards, harms and, consequently, their associated risks. The level of uncertainty that is associated with the area being risk assessed informs how much formality may be required to manage potential risks. Systematic approaches for acquiring, analysing, storing and disseminating scientific information are essential for generating knowledge, which in turn informs all quality risk management activities. Uncertainty may be reduced via effective knowledge management, which enables accumulated and new information (both internal and external) to be used to support risk-based decisions throughout the product lifecycle. • Importance: The more important a risk-based decision may be in relation to product quality, the higher the level of formality that should be applied, and the greater the need to reduce the level of uncertainty associated with it. • Complexity: The more complex a process or subject area is to a quality risk management activity, the higher the level of formality that should be applied to assure product quality. Higher levels of uncertainty, importance or complexity may require more formal quality risk management approaches to manage potential risks and to support effective risk-based decision- making. The overall approach for determining how much formality to apply during quality risk management activities should be described within the quality system. Resource constraints should not be used to justify the use of lower levels of formality in the quality risk management process. Risk scores, ratings and assessments should be based on an appropriate use of evidence, science and knowledge. Regardless of how much formality is applied, the robust management of risk is the goal of the process. === PAGE 12 === ICH Q9(R1) Guideline The following may be characteristics of higher levels of formality: • All parts of the quality risk management process (risk assessment, risk control, risk review and risk communication) are explicitly performed, and stand-alone quality risk management reports or related documents which address all aspects of the process may be generated and are documented (e.g., within the quality system). • Quality risk management tools, including those shown in Annex 1, are used in some or all parts of the process. • A cross-functional team is assembled for the quality risk management activity. • Use of a facilitator, with experience and knowledge of the quality risk management process, may be integral to a higher formality process. The following may be characteristics of lower levels of formality: • One or more parts of the quality risk management process are not performed as stand- alone activities but are addressed within other elements of the quality system which may have risk assessment and risk control activities embedded within them. • Quality risk management tools might not be used in some or all parts of the process. • A cross-functional team might not be necessary. • Stand-alone quality risk management reports might not be generated. The outcome of the quality risk management process is usually documented in the relevant parts of the quality system. Note: As indicated above, degrees of formality between the above higher and lower levels also exist and may be used. ### 5.2 Risk-Based Decision-Making Risk-based decision-making is inherent in all quality risk management activities; it provides an essential foundation for decision makers in an organization. Effective risk-based decision- making begins with determining the level of effort, formality and documentation that should be applied during the quality risk management process. The decisions made from quality risk management activities include those in relation to what hazards exist, the risks associated with those hazards, the risk controls required, the acceptability of the residual risk after risk controls, and also the communication and review of quality risk management activities and outputs. As all decision-making relies on the use of knowledge, see ICH Q10 for guidance in relation to knowledge management. It is important also to ensure the integrity of the data that are used for risk-based decision-making. Approaches to risk-based decision-making: There are different processes that may be used to make risk-based decisions; these are directly related to the level of formality that is applied during the quality risk management process. (See Section 5.1 above for guidance on what constitutes formality in quality risk management.) Higher levels of formality in quality risk management may require higher levels of structure in relation to risk-based decision-making. There can be varying degrees of structure with regard to approaches for risk-based decision-making. These degrees of structure can be considered to be on a continuum (or spectrum). Below are descriptions of highly structured vs. less structured processes, and for rule-based processes when making risk-based decisions: === PAGE 13 === ICH Q9(R1) Guideline • Some risk-based decision-making processes are highly structured and can involve a formal analysis of the available options that exist before making a decision. They involve an in- depth consideration of relevant factors associated with the available options. Such processes might be used when there is a high degree of importance associated with the decision, and when the level of uncertainty and/or complexity is high. • Other risk-based decision-making processes are less structured; here, simpler approaches are used to arrive at decisions, and they primarily make use of existing knowledge to support an assessment of hazards, risks and any required risk controls. Such processes might still be used when there is a high degree of importance associated with the decision, but the degree of uncertainty and/or complexity is lower. • Decisions might also be made using rule-based (or standardized) approaches, which do not require a new risk assessment to make such decisions. This is where there are SOPs, policies or well understood requirements in place which determine what decisions must be made. Here, rules (or limits) may be in place which govern such decisions; these may be based on a previously obtained understanding of the relevant risks and they usually lead to predetermined actions and/or expected outcomes. The above approaches to risk-based decision-making are beneficial because they address uncertainty through the use of knowledge, facilitating informed decisions by regulators and the pharmaceutical industry in a multitude of areas. They also help recognize where uncertainty remains, so that appropriate risk controls (including improved detection) may be identified to enhance understanding of those variables and further reduce the level of uncertainty. ### 5.3 Managing and Minimizing Subjectivity Subjectivity can impact every stage of a quality risk management process, especially the identification of hazards and the estimation of probability of occurrence and severity of harm. It can also impact the estimation of risk reduction and the effectiveness of decisions made from quality risk management activities. Subjectivity can be introduced in quality risk management through differences in how risks are assessed and in how hazards, harms and risks are perceived by different stakeholders, (e.g., bias). Subjectivity can also be introduced when risk questions are inadequately defined, and when tools have poorly designed risk scoring scales. While subjectivity cannot be completely eliminated from quality risk management activities, it may be controlled by addressing bias and assumptions, the proper use of quality risk management tools and maximizing the use of relevant data and sources of knowledge (see ICH Q10, Section 1.6.1). All participants involved with quality risk management activities should acknowledge, anticipate, and address the potential for subjectivity. 6. INTEGRATION OF QUALITY RISK MANAGEMENT INTO INDUSTRY AND REGULATORY OPERATIONS Quality risk management is a process that supports science-based and practical decisions when integrated into quality systems (see Annex II). As outlined in the introduction, appropriate use of quality risk management does not obviate industry’s obligation to comply with regulatory === PAGE 14 === ICH Q9(R1) Guideline requirements. However, effective quality risk management can facilitate better and more informed decisions, can provide regulators with greater assurance of a company’s ability to deal with potential risks, and might affect the extent and level of direct regulatory oversight. In addition, quality risk management can facilitate better use of resources by all parties. Training of both industry and regulatory personnel in quality risk management processes provides for greater understanding of decision-making processes and builds confidence in quality risk management outcomes. Quality risk management should be integrated into existing operations and documented appropriately. Annex II provides examples of situations in which the use of the quality risk management process might provide information that could then be used in a variety of pharmaceutical operations. These examples are provided for illustrative purposes only and should not be considered a definitive or exhaustive list. These examples are not intended to create any new expectations beyond the requirements laid out in the current regulations. Examples for industry and regulatory operations (see Annex II): • Quality management. Examples for industry operations and activities (see Annex II): • Development; • Facility, equipment and utilities; • Materials management; • Production; • Laboratory control and stability testing; • Packaging and labeling; • Supply chain control. Examples for regulatory operations (see Annex II): • Inspection and assessment activities. While regulatory decisions will continue to be taken on a regional basis, a common understanding and application of quality risk management principles could facilitate mutual confidence and promote more consistent decisions among regulators on the basis of the same information. This collaboration could be important in the development of policies and guidelines that integrate and support quality risk management practices. ### 6.1 The role of Quality Risk Management in Addressing Product Availability Risks Arising from Quality/Manufacturing Issues Quality/manufacturing issues, including non-compliance with Good Manufacturing Practice (GMP), are a significant cause of product availability issues (e.g., product shortages). The interests of patients are served by risk-based drug shortage prevention and mitigation activities that help to proactively manage supply chain complexities and ensure availability of needed drug (medicinal) products. While manufacturing and supply chain diversity can be enablers of product availability, increasingly complex supply chains lead to interdependencies that can introduce systemic quality/manufacturing risks impacting supply chain robustness. The application of quality risk management enables the proactive identification and implementation of preventive measures that support product availability. === PAGE 15 === ICH Q9(R1) Guideline An effective pharmaceutical quality system drives both supply chain robustness and sustainable GMP compliance. The pharmaceutical quality system, including management responsibilities, also uses quality risk management and knowledge management to provide an early warning system that supports effective oversight and response to evolving quality/manufacturing risks from the pharmaceutical company or its external partners. When risk-based drug shortage prevention and mitigation activities are performed, the level of formality that is applied to those activities may vary (see Section 5.1) and should be commensurate with the level of risk associated with a loss of availability of the product(s). Quality/manufacturing factors that can affect supply reliability, and hence product availability, include, but are not limited to, the following: a) Manufacturing Process Variability and State of Control: Processes that exhibit excessive variability (e.g., process drift, non-uniformity) have capability gaps that can result in unpredictable outputs (e.g., quality, timeliness and yield) and consequently can adversely impact product availability. Quality risk management can help design monitoring systems that are capable of detecting departures from a state of control and deficiencies in manufacturing processes, so they can be investigated to address root causes. b) Manufacturing Facilities and Equipment: A robust facility infrastructure can facilitate reliable supply; it includes suitable equipment and well-designed facilities for manufacturing (including packaging and testing). Robustness can be affected by multiple factors, such as an aging facility, insufficient maintenance or an operational design that is vulnerable to human error. Risks to supply can be reduced by addressing these factors, as well as through the use of modern technology, such as digitalization, automation, isolation technology, amongst others. c) Oversight of Outsourced Activities and Suppliers: Quality system governance includes assuring the acceptability of supply chain partners over the product lifecycle. Approval and oversight of outsourced activities and material suppliers is informed by risk assessments, effective knowledge management, and an effective monitoring strategy for supply chain partner performance. A successful manufacturing partnership is strengthened by appropriate communication and collaboration mechanisms (See Section 2.7 of ICH Q10). When substantial variability is identified in the quality and safety of supplied materials or in the services provided, enhanced review and monitoring activities are justified. In some cases, it may be necessary to identify a new supply chain entity (e.g., a pre-qualified alternative option) to perform a function. Note that the guidance in Annex II.2, in relation to the application of quality risk management as part of Regulatory Operations, can be useful to consider in the context of product availability risks. 7. DEFINITIONS Decision Maker(s): Person(s) with the competence and authority to make appropriate and timely quality risk management decisions. === PAGE 16 === ICH Q9(R1) Guideline Detectability: The ability to discover or determine the existence, presence, or fact of a hazard. Harm: Damage to health, including the damage that can occur from loss of product quality or availability. Hazard: The potential source of harm (ISO/IEC Guide 51:2014). Hazard Identification: The systematic use of information to identify potential sources of harm (hazards) referring to the risk question or problem description. Product Lifecycle: All phases in the life of the product from the initial development through marketing until the product’s discontinuation. Quality: The degree to which a set of inherent properties of a product, system or process fulfills requirements (see ICH Q6A definition specifically for “quality” of drug substance and drug (medicinal) products.) Quality Risk Management: A systematic process for the assessment, control, communication and review of risks to the quality of the drug (medicinal) product across the product lifecycle. Quality System: The sum of all aspects of a system that implements quality policy and ensures that quality objectives are met. Requirements: The explicit or implicit needs or expectations of the patients or their surrogates (e.g., health care professionals, regulators and legislators). In this document, “requirements” refers not only to statutory, legislative, or regulatory requirements, but also to such needs and expectations. Risk: The combination of the probability of occurrence of harm and the severity of that harm (ISO/IEC Guide 51:2014). Risk Acceptance: An informed decision to take a particular risk. (ISO Guide 73:2009). Risk Analysis: The estimation of the risk associated with the identified hazards. Risk Assessment: A systematic process of organizing information to support a risk decision to be made within a risk management process. It consists of the identification of hazards and the analysis and evaluation of risks associated with exposure to those hazards. === PAGE 17 === ICH Q9(R1) Guideline Risk-Based Decision-Making: An approach to, or a process of, making decisions that considers knowledge about risks relevant to the decision and whether risks are at an acceptable level. Risk Communication: The sharing of information about risk and risk management between the decision maker and other stakeholders. Risk Control: Actions implementing risk management decisions (ISO Guide 73:2009). Risk Evaluation: The comparison of the estimated risk to given risk criteria using a quantitative or qualitative scale to determine the significance of the risk. Risk Management: The systematic application of quality management policies, procedures, and practices to the tasks of assessing, controlling, communicating and reviewing risk. Risk Reduction: Actions taken to lessen the probability of occurrence of harm and the severity of that harm. Risk Review: Review or monitoring of output/results of the risk management process considering (if appropriate) new knowledge and experience about the risk. Severity: A measure of the possible consequences of a hazard. Stakeholder: Any individual, group or organization that can affect, be affected by, or perceive itself to be affected by a risk. Decision makers might also be stakeholders. For the purposes of this guideline, the primary stakeholders are the patient, healthcare professional, regulatory authority, and industry. Trend: A statistical term referring to the direction or rate of change of a variable(s). 8. REFERENCES 1. ICH Q8 Pharmaceutical Development. 2. ICH Q10 Pharmaceutical Quality System. 3. ICH Q11 Development and Manufacture of Drug Substances (Chemical Entities and Biotechnological/Biological Entities). 4. ICH Q12 Technical and Regulatory Considerations for Pharmaceutical Product Lifecycle Management. 5. ISO/IEC Guide 73:2009 - Risk Management - Vocabulary - Guidelines for use in Standards. 6. ISO/IEC Guide 51:2014 - Safety Aspects - Guideline for their inclusion in standards. === PAGE 18 === ICH Q9(R1) Guideline 7. IEC 61025 - Fault Tree Analysis (FTA). 8. IEC 60812:2018 Failure modes and effects analysis (FMEA and FMECA). 9. IEC 61882:2016 - Hazard and operability studies (HAZOP studies) – Application guide. 10. ISO 14971:2019 – Medical devices - Application of risk management to medical devices. 11. ISO 7870-1:2019 - Control Charts, General guidelines. 12. ISO 7870-4:2021- Cumulative Sum Charts. 13. ISO 7870-3:2020 - Acceptance Control Charts. 14. ISO 7870-2:2013 - Shewhart Control Charts. 15. WHO Technical Report Series No 908, 2003, Annex 7 Application of Hazard Analysis and Critical Control Point (HACCP) methodology to pharmaceuticals. 16. What is Total Quality Control?; The Japanese Way, Kaoru Ishikawa (Translated by David J. Liu), 1985, ISBN 0139524339. 17. Failure Mode and Effect Analysis, FMEA from Theory to Execution, 2nd Edition 2003, D. H. Stamatis, ISBN 0873895983. 18. Process Mapping by the American Productivity & Quality Center, 2002, ISBN 1928593739. 19. Parenteral Drug Association. Technical Report No. 54 Implementation of quality risk management for pharmaceutical and biotechnology manufacturing operations. 2012. 20. Parenteral Drug Association. Points to consider for aging facilities. 2017. 21. Parenteral Drug Association. Technical Report No. 68. Risk-based approach for prevention and management of drug shortages. 2014. 22. International Society for Pharmaceutical Engineering. Report on the ISPE Drug shortages survey. 2013. 23. International Society for Pharmaceutical Engineering. Drug shortages prevention plan. 2014. 24. Tabersky D, Woelfle M, Ruess J, Brem S, Brombacher S. Recent regulatory trends in pharmaceutical manufacturing and their impact on the industry. CHIMIA, 2018;72(3):146-150. 25. O’Donnell K, Tobin D, Butler S, Haddad G, Kelleher D. Understanding the concept of formality in quality risk management. J. Valid. Technol, 2020 Jun; 26(3). === PAGE 19 === ICH Q9(R1) Guideline ANNEX I: QUALITY RISK MANAGEMENT METHODS AND TOOLS The purpose of this annex is to provide a general overview of and references for some of the primary tools that might be used in quality risk management by industry and regulators. The references are included as an aid to gain more knowledge and detail about the particular tool. This is not an exhaustive list. It is important to note that no one tool or set of tools is applicable to every situation in which a quality risk management procedure is used. It is neither always appropriate nor always necessary to use highly formal quality risk management methods and tools. The use of less formal quality risk management methods and tools can also be considered acceptable. See Section 5.1 for guidance on what constitutes formality in quality risk management. I.1 Basic Risk Management Facilitation Methods Some of the simple techniques that are commonly used to structure risk management by organizing data and facilitating decision-making are: • Flowcharts; • Check Sheets; • Process Mapping; • Cause and Effect Diagrams (also called an Ishikawa diagram or fish bone diagram). I.2 Failure Mode Effects Analysis (FMEA) FMEA (see IEC 60812) provides for an evaluation of potential failure modes for processes and their likely effect on outcomes and/or product performance. Once failure modes are established, risk reduction can be used to eliminate, contain, reduce or control the potential failures. FMEA relies on product and process understanding. FMEA methodically breaks down the analysis of complex processes into manageable steps. It is a powerful tool for summarizing the important modes of failure, factors causing these failures and the likely effects of these failures. Potential Areas of Use(s) FMEA can be used to prioritize risks and monitor the effectiveness of risk control activities. FMEA can be applied to equipment and facilities and might be used to analyze a manufacturing operation and its effect on product or process. It identifies elements/operations within the system that render it vulnerable. The output/ results of FMEA can be used as a basis for design or further analysis or to guide resource deployment. I.3 Failure Mode, Effects and Criticality Analysis (FMECA) FMEA might be extended to incorporate an investigation of the degree of severity of the consequences, their respective probabilities of occurrence, and their detectability, thereby becoming a Failure Mode Effect and Criticality Analysis (FMECA; see IEC 60812). In order for such an analysis to be performed, the product or process specifications should be established. FMECA can identify places where additional preventive actions might be appropriate to minimize risks. Potential Areas of Use(s) FMECA application in the pharmaceutical industry should mostly be utilized for failures and risks associated with manufacturing processes; however, it is not limited to this application. === PAGE 20 === ICH Q9(R1) Guideline The output of an FMECA is a relative risk “score” for each failure mode, which is used to rank the modes on a relative risk basis. I.4 Fault Tree Analysis (FTA) The FTA tool (see IEC 61025) is an approach that assumes failure of the functionality of a product or process. This tool evaluates system (or sub-system) failures one at a time but can combine multiple causes of failure by identifying causal chains. The results are represented pictorially in the form of a tree of fault modes. At each level in the tree, combinations of fault modes are described with logical operators (AND, OR, etc.). FTA relies on the experts’ process understanding to identify causal factors. Potential Areas of Use(s) FTA can be used to establish the pathway to the root cause of the failure. FTA can be used to investigate complaints or deviations in order to fully understand their root cause and to ensure that intended improvements will fully resolve the issue and not lead to other issues (i.e. solve one problem yet cause a different problem). Fault Tree Analysis is an effective tool for evaluating how multiple factors affect a given issue. The output of an FTA includes a visual representation of failure modes. It is useful both for risk assessment and in developing monitoring programs. I.5 Hazard Analysis and Critical Control Points (HACCP) HACCP is a systematic, proactive, and preventive tool for assuring product quality, reliability, and safety (see WHO Technical Report Series No 908, 2003 Annex 7). It is a structured approach that applies technical and scientific principles to analyze, evaluate, prevent, and control the risk or adverse consequence(s) of haard(s) due to the design, development, production, and use of products. HACCP consists of the following seven steps: (1) conduct a hazard analysis and identify preventive measures for each step of the process; (2) determine the critical control points; (3) establish critical limits; (4) establish a system to monitor the critical control points; (5) establish the corrective action to be taken when monitoring indicates that the critical control points are not in a state of control; (6) establish system to verify that the HACCP system is working effectively; (7) establish a record-keeping system. Potential Areas of Use(s) HACCP might be used to identify and manage risks associated with physical, chemical and biological hazards (including microbiological contamination). HACCP is most useful when product and process understanding is sufficiently comprehensive to support identification of critical control points. The output of a HACCP analysis is risk management information that facilitates monitoring of critical points not only in the manufacturing process but also in other life cycle phases. === PAGE 21 === ICH Q9(R1) Guideline I.6 Hazard Operability Analysis (HAZOP) HAZOP (see IEC 61882) is based on a theory that assumes that risk events are caused by deviations from the design or operating intentions. It is a systematic brainstorming technique for identifying hazards using so-called “guide-words”. “Guide-words” (e.g., No, More, Other Than, Part of, etc.) are applied to relevant parameters (e.g., contamination, temperature) to help identify potential deviations from normal use or design intentions. It often uses a team of people with expertise covering the design of the process or product and its application. Potential Areas of Use(s) HAZOP can be applied to manufacturing processes, including outsourced production and formulation as well as the upstream suppliers, equipment and facilities for drug substances and drug (medicinal) products. It has also been used primarily in the pharmaceutical industry for evaluating process safety hazards. As is the case with HACCP, the output of a HAZOP analysis is a list of critical operations for risk management. This facilitates regular monitoring of critical points in the manufacturing process. I.7 Preliminary Hazard Analysis (PHA) PHA is a tool of analysis based on applying prior experience or knowledge of a hazard or failure to identify future hazards, hazardous situations and events that might cause harm, as well as to estimate their probability of occurrence for a given activity, facility, product or system. The tool consists of: 1) the identification of the possibilities that the risk event happens, 2) the qualitative evaluation of the extent of possible injury or damage to health that could result, 3) a relative ranking of the hazard using a combination of severity and likelihood of occurrence, and 4) the identification of possible remedial measures. Potential Areas of Use(s) PHA might be useful when analyzing existing systems or prioritizing hazards where circumstances prevent a more extensive technique from being used. It can be used for product, process and facility design as well as to evaluate the types of hazards for the general product type, then the product class, and finally the specific product. PHA is most commonly used early in the development of a project when there is little information on design details or operating procedures; thus, it will often be a precursor to further studies. Typically, hazards identified in the PHA are further assessed with other risk management tools such as those in this section. I.8 Risk Ranking and Filtering Risk ranking and filtering is a tool for comparing and ranking risks. Risk ranking of complex systems typically requires evaluation of multiple diverse quantitative and qualitative factors for each risk. The tool involves breaking down a basic risk question into as many components as needed to capture factors involved in the risk. These factors are combined into a single relative risk score that can then be used for ranking risks. “Filters,” in the form of weighting factors or cut-offs for risk scores, can be used to scale or fit the risk ranking to management or policy objectives. Potential Areas of Use(s) Risk ranking and filtering can be used to prioritize manufacturing sites for inspection/audit by regulators or industry. Risk ranking methods are particularly helpful in situations in which the portfolio of risks and the underlying consequences to be managed are diverse and difficult to === PAGE 22 === ICH Q9(R1) Guideline compare using a single tool. Risk ranking is useful when management needs to evaluate both quantitatively-assessed and qualitatively-assessed risks within the same organizational framework. I.9 Supporting Statistical Tools Statistical tools can support and facilitate quality risk management. They can enable effective data assessment, aid in determining the significance of the data set(s), and facilitate more reliable decision-making. A listing of some of the principal statistical tools commonly used in the pharmaceutical industry is provided: • Control Charts, for example: - Acceptance Control Charts (see ISO 7870-3:2020); - Cumulative Sum Charts (see ISO 7870-4:2021); - Shewhart Control Charts (see ISO 7870-2:2013); - Weighted Moving Average. • Design of Experiments (DOE); • Histograms; • Pareto Charts; • Process Capability Analysis. === PAGE 23 === ICH Q9(R1) Guideline ANNEX II: POTENTIAL APPLICATIONS FOR QUALITY RISK MANAGEMENT This Annex is intended to identify potential uses of quality risk management principles and tools by industry and regulators. However, the selection of particular risk management tools is completely dependent upon specific facts and circumstances. These examples are provided for illustrative purposes and only suggest potential uses of quality risk management. This Annex is not intended to create any new expectations beyond the current regulatory requirements. II.1 Quality Risk Management as Part of Integrated Quality Management Documentation To review current interpretations and application of regulatory expectations; To determine the desirability of and/or develop the content for SOPs, guidelines, etc. Training and education To determine the appropriateness of initial and/or ongoing training sessions based on education, experience and working habits of staff, as well as on a periodic assessment of previous training (e.g., its effectiveness); To identify the training, experience, qualifications and physical abilities that allow personnel to perform an operation reliably and with no adverse impact on the quality of the product. Quality defects To provide the basis for identifying, evaluating, and communicating the potential quality impact of a suspected quality defect, complaint, trend, deviation, investigation, out of specification result, etc; To facilitate risk communications and determine appropriate action to address significant product defects, in conjunction with regulatory authorities (e.g., recall). Auditing/Inspection To define the frequency and scope of audits, both internal and external, taking into account factors such as: • Existing legal requirements; • Overall compliance status and history of the company or facility; • Robustness of a company’s quality risk management activities; • Complexity of the site; • Complexity of the manufacturing process; • Complexity of the product and its therapeutic significance; • Number and significance of quality defects (e.g., recall); • Results of previous audits/inspections; • Major changes of building, equipment, processes, key personnel; • Experience with manufacturing of a product (e.g., frequency, volume, number of batches); === PAGE 24 === ICH Q9(R1) Guideline • Test results of official control laboratories. Periodic review To select, evaluate and interpret trend results of data within the product quality review; To interpret monitoring data (e.g., to support an assessment of the appropriateness of revalidation or changes in sampling). Change management / change control To manage changes based on knowledge and information accumulated in pharmaceutical development and during manufacturing; To evaluate the impact of the changes on the availability of the final product; To evaluate the impact on product quality of changes to the facility, equipment, material, manufacturing process or technical transfers; To determine appropriate actions preceding the implementation of a change, e.g., additional testing, (re)qualification, (re)validation or communication with regulators. Continual improvement To facilitate continual improvement in processes throughout the product lifecycle. II.2 Quality Risk Management as Part of Regulatory Operations Inspection and assessment activities To assist with resource allocation including, for example, inspection planning and frequency, and inspection and assessment intensity (see "Auditing" section in Annex II.1); To evaluate the significance of, for example, quality defects, potential recalls and inspectional findings; To determine the appropriateness and type of post-inspection regulatory follow-up; To evaluate information submitted by industry including pharmaceutical development information; To evaluate impact of proposed variations or changes; To identify risks which should be communicated between inspectors and assessors to facilitate better understanding of how risks can be or are controlled (e.g., parametric release, Process Analytical Technology (PAT)). II.3 Quality Risk Management as Part of Development To design a quality product and its manufacturing process to consistently deliver the intended performance of the product (see ICH Q8); === PAGE 25 === ICH Q9(R1) Guideline To enhance knowledge of product performance over a wide range of material attributes (e.g., particle size distribution, moisture content, flow properties), processing options and process parameters; To assess the critical attributes of raw materials, solvents, Active Pharmaceutical Ingredient (API) starting materials, APIs, excipients, or packaging materials; To establish appropriate specifications, identify critical process parameters and establish manufacturing controls (e.g., using information from pharmaceutical development studies regarding the clinical significance of quality attributes and the ability to control them during processing); To decrease variability of quality attributes: • reduce product and material defects; • reduce manufacturing defects. To assess the need for additional studies (e.g., bioequivalence, stability) relating to scale up and technology transfer; To make use of the “design space” concept (see ICH Q8). II.4 Quality Risk Management for Facilities, Equipment and Utilities Design of facility / equipment To determine appropriate zones when designing buildings and facilities, e.g., • flow of material and personnel; • minimize contamination; • pest control measures; • prevention of mix-ups; • open versus closed equipment; • clean rooms versus isolator technologies; • dedicated or segregated facilities / equipment. To determine appropriate product contact materials for equipment and containers (e.g., selection of stainless steel grade, gaskets, lubricants); To determine appropriate utilities (e.g., steam, gases, power source, compressed air, heating, ventilation and air conditioning (HVAC), water); To determine appropriate preventive maintenance for associated equipment (e.g., inventory of necessary spare parts). Hygiene aspects in facilities To protect the product from environmental hazards, including chemical, microbiological, and physical hazards (e.g., determining appropriate clothing and gowning, hygiene concerns); === PAGE 26 === ICH Q9(R1) Guideline To protect the environment (e.g., personnel, potential for cross-contamination) from hazards related to the product being manufactured. Qualification of facility/equipment/utilities To determine the scope and extent of qualification of facilities, buildings, and production equipment and/or laboratory instruments (including proper calibration methods). Cleaning of equipment and environmental control To differentiate efforts and decisions based on the intended use (e.g., multi- versus single- purpose, batch versus continuous production); To determine acceptable (specified) cleaning validation limits. Calibration/preventive maintenance To set appropriate calibration and maintenance schedules. Computer systems and computer controlled equipment To select the design of computer hardware and software (e.g., modular, structured, fault tolerance); To determine the extent of validation, e.g., • identification of critical performance parameters; • selection of the requirements and design; • code review; • the extent of testing and test methods; • reliability of electronic records and signatures. II.5 Quality Risk Management as Part of Materials Management Assessment and evaluation of suppliers and contract manufacturers To provide a comprehensive evaluation of suppliers and contract manufacturers (e.g., auditing, supplier quality agreements). Starting material To assess differences and possible quality risks associated with variability in starting materials (e.g., age, route of synthesis). Use of materials To determine whether it is appropriate to use material under quarantine (e.g., for further internal processing); To determine appropriateness of reprocessing, reworking, use of returned goods. === PAGE 27 === ICH Q9(R1) Guideline Storage, logistics and distribution conditions To assess the adequacy of arrangements to ensure maintenance of appropriate storage and transport conditions (e.g., temperature, humidity, container design); To determine the effect on product quality of discrepancies in storage or transport conditions (e.g., cold chain management) in conjunction with other ICH guidelines; To maintain infrastructure (e.g., capacity to ensure proper shipping conditions, interim storage, handling of hazardous materials and controlled substances, customs clearance); To provide information for ensuring the availability of pharmaceuticals (e.g., ranking risks to the supply chain). II.6 Quality Risk Management as Part of Production Validation To identify the scope and extent of verification, qualification and validation activities (e.g., analytical methods, processes, equipment and cleaning methods); To determine the extent for follow-up activities (e.g., sampling, monitoring and re-validation); To distinguish between critical and non-critical process steps to facilitate design of a validation study. In-process sampling & testing To evaluate the frequency and extent of in-process control testing (e.g., to justify reduced testing under conditions of proven control); To evaluate and justify the use of process analytical technologies (PAT) in conjunction with parametric and real time release. Production planning To determine appropriate production planning (e.g., dedicated, campaign and concurrent production process sequences). II.7 Quality Risk Management as Part of Laboratory Control and Stability Studies Out of specification results To identify potential root causes and corrective actions during the investigation of out of specification results. Retest period / expiration date To evaluate adequacy of storage and testing of intermediates, excipients and starting materials. === PAGE 28 === ICH Q9(R1) Guideline II.8 Quality Risk Management as Part of Packaging and Labeling Design of packages To design the secondary package for the protection of primary packaged product (e.g., to ensure product authenticity, label legibility). Selection of container closure system To determine the critical parameters of the container closure system. Label controls To design label control procedures based on the potential for mix-ups involving different product labels, including different versions of the same label. II.9 Quality Risk Management as Part of Supply Chain Control With regard to product availability risks related to quality/manufacturing issues, product lifecycle oversight of the supply chain includes maintaining current knowledge of quality/manufacturing hazards and prioritizing efforts to manage such risks. Understanding hazards to quality/manufacturing is critical to maintaining supply predictability. When risks are well understood and controlled, a higher confidence in product availability can be attained. Manufacturing Process Variation and State of Control To decrease variability in the manufacturing process (e.g., process drift, non-uniformity) and associated capability gaps that can result in unpredictable outputs, adversely impact quality and consequently timeliness, yield and product availability; To design monitoring systems that are capable of detecting departures from a state of control and deficiencies in manufacturing processes, so they can be appropriately investigated to determine root causes and any required risk mitigations. Manufacturing Facilities and Equipment To ensure that facility infrastructure and equipment are suitable and designed for robust manufacturing (this includes packaging and testing) (see Annex II.4); To establish facility and equipment maintenance programmes that assure reliable facility and equipment performance; To ensure that the operational design of equipment is not vulnerable to human error; To obtain quality and efficiency gains through the utilization of digitalization, automation, isolation technology, and other innovations. Supplier Oversight and Relationships To enhance review and monitoring activities (see Section 2.7 of ICH Q10) when substantial === PAGE 29 === ICH Q9(R1) Guideline variability is identified in the quality and safety of supplied materials or in the services provided. To manage external product availability risks relating to quality/manufacturing, (e.g., from raw material suppliers, contracted organizations, service providers, etc.) --- ### Document: Sterile Pharmaceutical Manufacturing: A Review of Barrier Isolation Technologies, Environmental Monitoring Systems, and QA/QC Validation Standards under EU GMP Annex 1 (PLS Academic Review) # Sterile Pharmaceutical Manufacturing: A Review of Barrier Isolation Technologies, Environmental Monitoring Systems, and QA/QC Validation Standards under EU GMP Annex 1 **Author:** Priya Life Science Academic Editorial Board **Published:** June 2026 **Document Classification:** Technical Report (PLS-TR-2026-001) **Subject Area:** Pharmaceutical Engineering, Quality Assurance, Quality Control, Sterile Processing Compliance --- ## Abstract Modern sterile pharmaceutical manufacturing requires a holistic contamination control strategy (CCS) to eliminate the risk of microbial and particulate contamination. With the 2023 finalization of the EU GMP Annex 1 revision, regulatory expectations have shifted from relying solely on end-product testing to active, risk-based containment and inline quality assurance. This review examines the scientific and engineering principles underpinning Restricted Access Barrier Systems (RABS) and Isolator technologies. Furthermore, it outlines the design, validation, and execution of comprehensive Environmental Monitoring (EM) programs in Grade A/B cleanrooms, emphasizing the integration of continuous viable and non-viable particulate tracking. --- ## 1. Introduction to Sterile Containment Systems The primary vector of microbial contamination in cleanroom environments is the human operator. Standard cleanroom garments reduce, but do not eliminate, the shedding of skin flakes, hair, and respiratory droplets. Consequently, modern aseptic processing focuses on physical separation of the operator from the critical Grade A exposure zone. Two primary technologies dominate advanced aseptic containment: 1. **Isolator Systems:** Fully sealed, pressurized enclosures that undergo automated bio-decontamination (typically using gaseous hydrogen peroxide, VHP) and are completely isolated from the surrounding room environment. 2. **Restricted Access Barrier Systems (RABS):** Enclosures that provide physical separation between the operator and the critical zone, utilizing unidirectional airflow (UDAF). RABS can be open or closed, but they allow intervention through gloveports or, under strict controls, open doors. ### Table 1: Technical Comparison of Containment Interfaces | Parameter | Restricted Access Barrier Systems (RABS) | Isolator Systems | | :--- | :--- | :--- | | **Physical Isolation** | High (physical barrier with open/closed doors) | Complete (hermetically sealed, gas-tight) | | **Surrounding Environment** | Minimum Grade B background required | Grade C or D background acceptable | | **Decontamination Method** | Manual chemical disinfection (sporicidal agents) | Automated gaseous de-pyrogenation / VHP | | **Transfer System** | Pass-through hatches, LAF transfer carts | Rapid Transfer Ports (RTP), isolator docks | | **Intervention Risk** | Moderate (doors can be opened under strict controls) | Extremely Low (interventions restricted to gloveports) | --- ## 2. Aerodynamics and Air Handling in Containment Aseptic zones require strict control over cleanroom aerodynamics. The standard for Grade A zones is unidirectional vertical airflow (UDAF) with an homogeneous air velocity of **0.45 m/s ± 20%** at the working position. ### 2.1 First Air Concept The "First Air" concept dictates that critical aseptic manipulations (e.g., stopper insertion, vial filling) must be performed in undisturbed, HEPA-filtered air that has not previously flowed over any equipment surfaces, operators, or secondary structures. Any disruption in this laminar flow pattern introduces turbulence, eddies, and potential entrainment of particles. ### 2.2 Pressure Differentials To maintain containment integrity, differential pressures must be established across cleanroom boundaries: * **Positive Pressure Enclosures:** Used for non-toxic aseptic products. The aseptic core is maintained at a minimum of **+10 to +15 Pascals** relative to the adjacent background zone to prevent ingress of non-sterile air. * **Negative Pressure Enclosures:** Employed for highly potent active pharmaceutical ingredients (HPAPIs), cytotoxic drugs, and radiopharmaceuticals. The containment zone is maintained at negative pressure to prevent toxic substance egress while ensuring aseptic protection through vertical laminar flow and dedicated exhaust HEPA filtration. --- ## 3. Environmental Monitoring (EM) Systems (QA/QC Framework) An Environmental Monitoring (EM) program is not a tool to control contamination; rather, it is a diagnostic mechanism to validate that the cleanroom is operating in a state of control. ### 3.1 Non-Viable Airborne Particulate Monitoring Particulate counters draw continuous air samples to detect inert particles. Under EU GMP Annex 1, the limits for non-viable particulates are strictly defined based on occupancy states ("at rest" vs. "in operation"). ``` ISO Grade 5 / Grade A Particulate Limits (Per Cubic Meter of Air) At Rest (Static) In Operation (Dynamic) ≥ 0.5 m: 3,520 ≥ 0.5 m: 3,520 ≥ 5.0 m: 29 ≥ 5.0 m: 29 ``` *Note: The 2023 revision of Annex 1 reinstated the limits for ≥ 5.0 m particles in Grade A zones to detect early-warning signals of mechanical wear, macro-contamination, or air handling degradation.* ### 3.2 Viable Microbial Monitoring Microbiological monitoring detects live, replicating microorganisms. Methods include: * **Active Air Samplers:** Volumetric collection of air (typically 1,000 liters) onto agar plates (TSA or SDA) to quantify Colony Forming Units (CFU) per cubic meter. * **Settle Plates:** Passive exposure of 90mm agar plates for up to 4 hours in critical Grade A areas. * **Contact Plates:** 55mm agar plates pressed directly onto surfaces (walls, floors, equipment, gloves) to test surface sanitization efficiency. * **Glove Prints:** Operators must perform 5-finger impressions on agar plates upon exiting Grade A zones to verify manual technique and glove integrity. ### Table 2: Microbial Contamination Limits (Recommended Action Levels) | Grade | Active Air Sample (CFU/m³) | Settle Plates (90mm, CFU/4 hours) | Contact Plates (55mm, CFU/plate) | Glove Print (5 fingers, CFU/glove) | | :--- | :--- | :--- | :--- | :--- | | **Grade A** | < 1 (No growth) | < 1 (No growth) | < 1 (No growth) | < 1 (No growth) | | **Grade B** | 10 | 5 | 5 | 5 | | **Grade C** | 100 | 50 | 25 | N/A | | **Grade D** | 200 | 100 | 50 | N/A | --- ## 4. Contamination Control Strategy (CCS) Validation Validation is the documented evidence that a process, equipment, or utility consistently performs to its pre-determined specifications. Under the latest regulatory updates, validation must be structured under a comprehensive **Contamination Control Strategy (CCS)**. ### 4.1 Sterilization and Depyrogenation * **Autoclaving (Moist Heat):** Minimum cycle of **121°C for 15 minutes** (F0 ≥ 15) to achieve a Sterility Assurance Level (SAL) of $10^{-6}$. * **Dry Heat (Depyrogenation):** Minimum of **250°C for 30 minutes** to achieve a 3-log reduction in endotoxins. * **Vaporized Hydrogen Peroxide (VHP):** Cycle development using biological indicators (typically *Geobacillus stearothermophilus*) to prove a 6-log reduction ($10^{-6}$) on all exposed internal surfaces. ### 4.2 Aseptic Process Simulation (Media Fills) The ultimate validation of an aseptic processing line is the Media Fill. In this simulation, the active pharmaceutical ingredient is replaced with a sterile microbiological growth medium (e.g., Tryptic Soy Broth). * **Scope:** The simulation must encompass all standard interventions (such as weight adjustments, line stoppage clearing, charging stopper bowls) and non-standard/emergency interventions (such as power failure restarts). * **Acceptance Criteria:** For fill sizes under 5,000 units, any contamination is cause for concern. For runs over 10,000 units, the goal is **zero contaminated units**. Any positive unit must trigger a comprehensive investigation, root cause analysis (using fishbone/5-Why methodologies), and repeat validation runs. --- ## 5. Conclusion Aseptic manufacturing is moving rapidly toward human-free operations. The implementation of isolators, automated transfer systems, and continuous, automated environmental monitoring represents the absolute standard for minimizing pharmaceutical risk. Achieving compliance with international regulatory bodies (FDA, EMA, HPRA) requires continuous evaluation of mechanical controls, microbiological dynamics, and documented QA/QC validation protocols. --- ## References 1. *European Commission.* (2023). EudraLex Volume 4, Annex 1: Manufacture of Sterile Medicinal Products. 2. *U.S. Food and Drug Administration (FDA).* (2004). Guidance for Industry: Sterile Drug Products Produced by Aseptic Processing — Current Good Manufacturing Practice. 3. *International Society for Pharmaceutical Engineering (ISPE).* (2018). Baseline Guide Volume 3: Sterile Product Manufacturing Facilities. 4. *Parenteral Drug Association (PDA).* (2015). Technical Report No. 13: Fundamentals of an Environmental Monitoring Program. ---